1. TELEPHONE EXCHANGE MCT 425 GAS DETECTORS Fa DETECTOR MCT 442 MCT 440 441 MCT 550 Figure 2 System Configuration SPECIFICATIONS General Data Transmitter Battery Life 3 years for typical use Frequency MHz 315 433 92 868 95 869 2125 869 2375 or according to local requirements Display Dual line backlit 16 character AMBER SELECT only with 3 LED indicators Supply Voltage 12 VAC 1 A via 120VAC 60Hz transformer Battery Pack NI MH 9 6 V 1 8 Ah type GP 0 9912 G LEDs POWER Green Normally ON indicating that your system is properly connected to the power outlet TROUBLE Red Normally OFF If LED flashes there is a problem with the AMBER SELECT AMBER SELECT or one of the devices described on the display of AMBER SELECT STATUS Yellow Normally OFF which indicates the system is in HOME mode FLASHES when unit is in AWAY mode display D 301438 ION DETECTOR A NEXT K9 85 AN a REY WA MOTI FLOOD PRIVATE PHONE MONITORING CENTER DOOR CONTACT EA MCT 302N Special Functions Calling for help by using an emergency pendant transmitter Speakerphone hands free when communicating with Monitoring Center or when answering an incoming call by pressing the pendant The system supports up to 29 users pendant transmitters and smoke detectors Two way voice communication Computer control and data download
2. AMBER SELECT runs on electrical power 1 Insert the plug on the power cord into the AC connector on the AMBER SELECT AMBER SELECT 2 Insert the safety catch tab horizontally into the hole to the right of the power cord plug as shown in Figure 3a 3 Turn the safety catch screw observing the polarity of the arrow in Figure 3a until facing the other hole Then secure the screw 4 Connect the AC AC adapter into a nearby electrical outlet DO NOT USE AN OUTLET CONTROLLED BY A WALL SWITCH When the panel is not installed all three LEDs light AMBER SELECT to indicate this status Audio prompts announce AC Telco or battery problem in the event of such a problem Caution When the plug is removed the unit is disconnected from the mains supply and will run on the battery pack for a period of up to 24 hours or until the plug is reconnected When electrical power is supplied to the AMBER SELECT the green light on the front panel illuminates Step 4 The Unit is now connecting you to the Monitoring Center After installation a Monitoring Center representative will begin speaking to you When your Monitoring Center representative answers you can hear them talking to you through the Unit You can talk to the representative by speaking out loud You do not need to use the phone The Monitoring Center representative will guide you through the rest of the system setup D 301438 MOUNTING THE UNIT The Un
3. pressing this button activates the speaker phone Alternatively press your emergency pendant button once during an incoming call Acknowledge Programmed Reminders such as confirming you have taken medication Change the status of the unit to HOME or AWAY To do this press this button continuously for 5 seconds Announce Time press this button for 1 second Arm or disarm the alarm system D 301438 Mounting on k the Wall 7 Drill 2 holes in the mounting wall and insert wall anchors Insert 2 screws in the wall leave a 5mm or 0 2 inch gap between the screw heads and the wall Mount the AMBER SELECT AMBER SELECT on the screws as shown in the illustration Figure 5 Wall Mounting A To do so press and hold the CHECK button for 3 seconds only when Intrusion mode is enabled B Press the button on the arm disarm transmitter MCT201WP e Direct Link Speed Dial The AMBER SELECT AMBER SELECT includes 3 buttons for unique direct link Using your Pendant Transmitter The pendant transmitter can be used to initiate an emergency call and also to answer incoming calls Pendant Activation Your pendant transmitter lets you signal to the AMBER SELECT AMBER SELECT from anywhere in your home when you need emergency assistance You should wear your pendant transmitter whenever you are at home even in the shower or bath Your pendant transmitter is waterproof Your pe
4. H button at any time to return to normal operation mode This does not affect current time date settings System Reset To reset the system simply insert a paperclip into the reset switch hole on the bottom of the AMBER SELECT AMBER SELECT Alternatively press the 3 speed dial buttons continuously for four seconds RESET SWITCH 2 7 Figure 6 Reset Switch D 301438 Direct link The direct link buttons function as follows e The AMBER SELECT AMBER SELECT dials the programmed telephone number stored in memory location 1 2 or 3 and operates the unit as a speaker phone e Used for scrolling between fields when setting the clock e Used for adjusting the volume during two way voice communication with incoming calls or for calls performed using the direct link buttons Press direct link button 1 to increase the volume or direct link button 3 to decrease the volume Programming of the direct link buttons is performed by the Monitoring Center The stored telephone numbers may be modified at any time In the Event of Smoke Smoke Detector Optional Your system can monitor up to 29 optional smoke detectors purchased separately If a smoke detector detects smoke the smoke detector will sound its alarm and signal the AMBER SELECT AMBER SELECT The AMBER SELECT AMBER SELECT calls the Monitoring Center to report a possible fire Then the Monitoring Center representative answers the situation
5. Monitoring Center or a private phone and sends an emergency alarm When your Monitoring Center representative or the person on the private phone answers you can hear them talking to you through the AMBER SELECT AMBER SELECT If you have a phone connected to the AMBER SELECT AMBER SELECT and want to use the phone to talk with the representative let the representative know and the Monitoring Center will return your call Trouble Trouble conditions are indicated by the flashing trouble LED and by the sounding of beeps and are immediately reported to the Monitoring Center LED Definition Green power On AC power and battery power OK Flashes AC or battery problem detected Yellow Off Away mode On Home mode Flashes Active reminder Trouble messages are shown on the unit s display AMBER SELECT only until they are resolved Pressing the CHECK button V confirms the trouble condition and cancels the beeps The AMBER SELECT AMBER SELECT continues to transmit trouble messages every eight hours until the problem is resolved Changing System Status When the user wants to leave the premises the unit status must be changed to AWAY mode The CHECK button Y should be held down for 5 seconds 3 seconds in Intrusion mode The unit announces and displays AMBER SELECT only AWAY REMINDERS OFF In this state no medication reminders and no pendant checks will be announced The unit s speaker is disabl
6. Please contact your seller for information on battery replacement When a Smoke Battery is Low When a smoke detector s battery voltage is low the smoke detector beeps every 35 seconds to alert you and will continue to beep until the detector s battery is replaced The unit s display AMBER SELECT only shows LOW BATTERY and the smoke detector s name Your system informs the Monitoring Center The smoke detector s batteries should last at least one year To replace the batteries refer to the instructions provided with the smoke detector Detector s D 301438 TROUBLESHOOTING The following table provides a list of problems that may arise with the system together with possible solutions PROBLEM The red light on the AMBER SELECT AMBER SELECT is flashing and beeps are heard DEFINITION The Base Unit informs your Monitoring Center that there is a problem SOLUTION Press the CHECK button i to silence the trouble beeps Respond to the message on the unit s display AMBER SELECT only The display AMBER SELECT only shows AC POWER FAILURE No electrical power is being supplied to the AMBER SELECT AMBER SELECT The AMBER SELECT AMBER SELECT is running on backup battery power The AMBER SELECT AMBER SELECT informs your Monitoring Center after two min Check to see if there is a power failure If there has not been a power failure make sure the power cord is connected securely to the AM
7. RF SUPERVISION 106 NON EMERGENCY 383 SENSOR TAMPER 110 FIRE ALARM 384 RF LOW BATTERY 122 SILENT ALARM 401 HOME AWAY 131 PERIMETER ALARM 412 SUCCESS DOWNLOAD 132 INTERIOR ALARM 456 FORCE ARM 134 ENTRY EXIT ALARM 602 PERIODIC TEST REPORT 151 GAS DETECTED 606 LISTEN IN TO FOLLOW 154 WATER FLOW ALARM 608 PERIODIC TEST SYS TBL PRESENT 301 AC LOSS 611 POINT TESTED OK 302 LOW SYSTEM BATTERY 612 POINT NOT TESTED 305 SYSTEM RESET 616 SENIOR WATCH TROUBLE 308 SYSTEM SHUTDOWN 626 SERVICE REQUEST 309 BATTERY TEST FAIL 641 TIME DATE INACCURATE 10 D 301438 COMPLIANCE 15 19 a 3 AMBER SELECT AMBER SELECT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received 15 21 Statement Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 5 Fora Class B digital device the instructions furnished the user shall include the following or similar statement placed in a prominent location in the text of the user or instruction manual 15 105 Statement NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter
8. failure to follow recommended installation and operational instructions neglect willful damage misuse or vandalism accidental damage alteration or tampering or repair by anyone other than the manufacturer are not covered by this Warranty The Manufacturer does not represent that this Product may not be compromised and or circumvented or that the Product will prevent any death and or personal injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection The Product properly installed and maintained only reduces the risk of such events without warning and it is not a guarantee or insurance that such events will not occur THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS OR LIABILITIES WHETHER WRITTEN ORAL EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER AS AFORESAID THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS DAMAGE OR EXPENSE INCLUDING LOSS OF USE PROFITS REVENUE OR GOODWILL DIRECTLY OR INDIRECTLY ARISING FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT OR FOR LOSS OR DESTRUCTION OF OT
9. is assessed and the appropriate response is determined In the Event that User Falls Fall Detector Optional The fall detector is activated once the unit is tilted by more than 60 in any direction The period of time until the fall detection is reported and the number of times that the local announcement is repeated can be programmed according to user needs The AMBER SELECT AMBER SELECT will announce USER HAS FALLEN If during this time the user restores the fall detector to its upright position the unit will announce USER IS Ok In the Event that No Activity is detected Motion Detector Transmitter Optional The motion detector and door contact transmitter are used to monitor the user s activity If no activity is detected by the enrolled transmitter s during a pre defined time the AMBER SELECT AMBER SELECT will report an inactivity condition to the Monitoring Center which will initiate a two way voice communication Inactivity time periods are defined remotely by the central station Non Emergency Services CALL The Monitoring Center provides non emergency concierge type services When you press the CALL button J the unit displays AMBER SELECT only CALL WAS PRESSED If NON EMERGENCY services are available to you the AMBER SELECT AMBER SELECT will contact the D 301438 Monitoring Center communication You can use the CALL button J to speak to a Monitoring Center representat
10. 68 rules and requirements adopted by ACTA and properly installed RJ31X connector See Installation Instructions for details 3 If the AMBER SELECT AMBER SELECT causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required If advance notice is not practical you will be notified as soon as possible Also you will be advised of your right to file a compliant with the FCC if it is necessary 4 The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service 5 If trouble is experienced with the AMBER SELECT AMBER SELECT for repair or warranty information please contact Visonic Inc USA 65 West Dudley Town Road Bloomfield CT 06002 phone number 8 602 430 833 URL www visonic com If the equipment is causing harm to the telephone network the telephone company may request to disconnect the equipment until the problem is resolved 6 The AMBER SELECT AMBER SELECT installation is described in the User Guide Connection to telephone company provided coin service is prohibited Connection to party lines service is subject to state tariffs 7 Wireless emergency response system must be able to seize the telephone line and plac
11. AMBER SELECT al Visonic AMBER SELECT User s Guide Wireless Emergency Response System D 301438 1 Wireless Emergency Response System Congratulations on your purchase of the wireless AMBER SELECT AMBER SELECT Personal Emergency Response system The AMBER SELECT operates the same as the AMBER SELECT but without a display This home health care signaling system was designed to support people in their home environment In the event of an emergency help can be summoned at the press of a button and that same message can be sent to private numbers that you have selected for notification In the event of fire the system can be programmed to automatically call the monitoring station or to private phones The Unit includes a large display not applicable to AMBER SELECT that shows the system status the time and preprogrammed medication reminders The Unit s rechargeable backup battery can provide up to 24 hours of operation When AC power is restored the backup battery is automatically recharged What s Included Before you begin to set up your system make sure you have all the necessary components e AMBER SELECT AMBER SELECT Unit e 120VAC to 12VAC transformer type OH 48109AT Input 120VAC 60 Hz Output 12VAC 1000 mA e Pendant transmitters supplied with necklace Additional Accessories Optional e Battery operated smoke detector MCT 425 e Waterproof arm disarm security activation pendant tran
12. BER SELECT AMBER SELECT and the electrical outlet The display AMBER SELECT only shows TELEPHONE LINE TROUBLE The unit does not detect that a working phone line is present Make sure the phone cord is connected securely to the AMBER SELECT AMBER SELECT and to the phone jack on the wall If the problem persists report the problem to your Monitoring Center The AMBER SELECT AMBER SELECT beeps continuously The AMBER SELECT AMBER SELECT is malfunctioning Press the CHECK button to silence the trouble beeps Contact your Monitoring Center The display AMBER SELECT only shows AMBER SELECT AMBER SELECT LOW BATTERY The AMBER SELECT AMBER SELECT s batteries are low The AMBER SELECT AMBER SELECT informs your Monitoring Center Batteries will be recharged when AC power is restored The display AMBER SELECT only shows the device name and LOW BATTERY or BATTERY TROUBLE A pendant transmitters or a smoke detector s battery is low The AMBER SELECT AMBER SELECT informs your Monitoring Center Contact your representative Monitoring Center You hear strange tones when using the phone Your AMBER SELECT AMBER SELECT is trying to call your Monitoring Center Hang up so your system can report a problem to the Monitoring Center When it finishes you can use the phone You hear noise interference when using your cordless phone The cordless phon
13. HER PROPERTY OR FROM ANY OTHER CAUSE EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL AND OR BODILY INJURY AND OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION A product and not re everyday waste Directive 2002 96 EC Waste Electrical and Electronic Equipment al Visonic urning it for repair VISONIC LTD ISRAEL P O B 22020 TEL AVIV 61220 ISRAEL PHONE 972 3 645 6789 FAX 972 3 645 6788 65 WEST DUDLEY TOWN ROAD BLOOMFIELD CT 06002 1376 PHONE 860 243 0833 800 223 0020 FAX 860 242 8094 7 COPPERHOUSE COURT CALDECOTTE MILTON KEYNES MK7 8NL TEL 0870 7300800 FAX 0870 7300801 VISONIC INC U S A VISONIC LTD UK INTERNET www visonic com VISONIC LTD 2008 AMBER SELECT AMBER SELECT USER GUIDE D 301438 12 REV 2 09 08 Customer Premises Equipment and Wiring Computer Unused RJ 11 Jack Telephone Unused RJ 11 Jack Fax Machine Telephone However if the Manufacturer is held liable whether directly or indirectly for any loss or damage arising under this limited warranty THE MANUFACTURER S MAXIMUM LIABILITY IF ANY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT which shall be fixed as liquidated damages and not as a penalty and shall be the compl
14. MBER SELECT unit press and hold the CHECK button for 3 seconds The unit announces ARMING AWAY PLEASE EXIT NOW and displays AMBER SELECT only EXIT on the screen At the end of exit delay the unit announces AWAY REMINDERS OFF and displays AMBER SELECT only AWAY on the screen to inform you that the system is in AWAY state When a delay zone is entered the unit announces PLEASE DISARM and displays AMBER SELECT only ENTRY on the screen To inform you that the system is 7 in disarmed state at the end of an entry delay or after pressing the button on the MCT 201WP the unit announces HOME REMINDERS ON and displays AMBER SELECT only HOME on the screen If any Zone in your home is opened except the Delay Zone during the system arming a beep protest will sound during Exit delay time out if enabled by the central station and stopped if this Zone is closed If the Zone is still opened after the system is in Arm state this zone will be automatically bypassed except in the case of an EXIT ENTRY zone until system rearming Note Reminders are active during Home mode and are disabled during Away and Exit Entry delay mode Entry exit delay can be programmed by the HHCPC software TESTING PROCEDURES The following are the necessary procedures for testing relevant system devices User Test Mode There are two ways to enter User Test mode e During every 2 way voice communication with the monitoring center or a privat
15. e a call in an emergency situation It must be able to do this even if other equipment telephone answering system computer modem etc already has the telephone line in use To do so AMBER SELECT AMBER SELECT must be connected to a properly installed RU31X jack that is electrically in series with and ahead of all other equipment attached to the same telephone line Proper installation is depicted in the figure below If you have any questions concerning these instructions you should consult your telephone company or a qualified installer about installing the RJ31X jack and AMBER SELECT AMBER SELECT for you Network Service Provider s Facilities Alarm Dialing Equipment Telephone Line Network Demarcation Point Telephone va Answering System WARRANTY Visonic Limited the Manufacturer warrants this product only the Product to the original purchaser only the Purchaser against defective workmanship and materials under normal use of the Product for a period of twelve 12 months from the date of shipment by the Manufacturer This Warranty is absolutely conditional upon the Product having been properly installed maintained and operated under conditions of normal use in accordance with the Manufacturers recommended installation and operation instructions Products which have become defective for any other reason according to the Manufacturers discretion such as improper installation
16. e first and then to call for help Never go back inside the house until authorized by the fire department Ensure that all members of the family memorize the emergency phone number of the fire department This will allow a member of the household to call for help from a cellular phone or from a neighbor s home Be fully prepared for a real fire when a smoke alarm sounds get out of the house immediately and do not return to the house until authorized to do so by the fire department If you live in an apartment building make sure that you are familiar with the building evacuation plan In the event of a fire use the stairs never the elevator Inform guests or visitors to your home about your family s fire escape plan When visiting other homes ask the occupants about their escape plan if they have one If they do not point out the importance of such a plan and offer to help them prepare one This is particularly important when children attend sleepovers at friends homes Warning Owners Instructions Notice Smoke detectors shall not be removed by anyone except by occupants APPENDIX B CONTACT ID EVENT CODES Code Definition Code Definition 101 PERSONAL EMERGENCY 311 BATTERY DEAD 102 FAIL TO REPORT WAKEUP 350 COM TROUBLE 103 FAIL TO REPORT WELLNESS CHECK 351 TELCO FAULT 104 FAIL TO REPORT HEALTH TEST 380 SENSOR TRBL 105 FAIL TO REPORT MEDICATION 381 LOSS OF
17. e might be picking up noise interference from the AMBER SELECT AMBER SELECT If the cordless phone s base is connected to the AMBER SELECT AMBER SELECT connect the phone to a phone jack away from the AMBER SELECT AMBER SELECT If the cordless phone s base is not connected to the AMBER SELECT AMBER SELECT move the phone s base farther away from the AMBER SELECT AMBER SELECT The clock blinks continuously The AMBER SELECT AMBER SELECT has been reset Refer to the section Clock Adjustment page 8 The display AMBER SELECT only freezes or no response when pressing buttons The AMBER SELECT AMBER SELECT is jammed Refer to the section System Reset page 8 D 301438 APPENDIX A HOME FIRE ESCAPE PLANNING The onset of a fire can often spread rapidly throughout your home leaving you with little time to escape safely Getting out of the house depends largely on advance warning from smoke detectors together with an advance planning strategy namely a home fire escape plan familiar to all members of your family and which has previously been put into practice Perform the following steps Make preparations with members of your family to conduct an evacuation plan Draw a floor plan of your home displaying two possible exit areas of each room including windows Don t forget to mark the location of every installed smoke detector Test all smoke detectors peri
18. e phone the AMBER SELECT AMBER SELECT automatically enters User Test mode once the operator uses the telephone line e During a telephone conversation the party at the other end of the telephone line must press in order to enter user test mode When the call ends the telephone line returns to normal mode In the USER TEST mode the AMBER SELECT AMBER SELECT announces a verbal message upon reception of a transmission from an enrolled detector This verbal message consists of two parts Detector Name and Signal Strength MAINTAINING YOUR SYSTEM The transmitter may get dirty if touched with greasy fingers Clean it only with a soft cloth or sponge moistened lightly with a mixture of water and mild detergent and wipe it dry immediately The use of abrasives of any kind is strictly forbidden Also never use solvents such as kerosene acetone or thinner When a Pendant s Battery is Low When a pendant transmitter s battery is low the supervised MCT 212 flashes rapidly several times per second and the red light on the AMBER SELECT AMBER SELECT flashes continuously until the pendant s battery is replaced The display AMBER SELECT only shows LOW BATTERY and the pendant transmitter s name Your system informs the Monitoring Center In the alarm state the unit announces ALARM then the Amber will start its communication sequence to either private or central station telephone numbers according to pre defined pa
19. ed and the yellow LED flashes In addition in AWAY mode inactivity detection is also disabled 6 If the pendant transmitter button is pressed while in the AWAY mode the unit will sound EMERGENCY and reports to the Monitoring Center This initiates two way communication through the speaker In addition any device that is alarmed while in AWAY mode immediately initiates a call to the Monitoring Center as in HOME mode and also initiates two way communication To return the status to HOME mode hold down the CHECK button VW for 5 seconds The unit s speaker will announce and display AMBER SELECT only HOME REMINDERS ON The status LED Y will turn off Clock Adjustment Announcement To Set the Clock AMBER SELECT 1 To enter the clock adjustment mode press the CHECK button V three consecutive times After each press be sure to wait for the time announcement to complete before pressing again The top line assigned to the Month will begin to flash 08 25 53 PM 2 Use Direct Link buttons 1 scrolls up and 2 scrolls down to set the current field value 3 Press Direct Link button 3 to scroll to select other fields month day year hours minutes and seconds 4 Press the Check button Y to set a new date or time value Clock Announcement AMBER SELECT Press the CHECK button to receive clock and status announcement Note Clock adjustment is performed by the HHCPC software Note Press the Call
20. ete and exclusive remedy against the Manufacturer When accepting the delivery of the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply under certain circumstances The Manufacturer shall be under no liability whatsoever arising out of the corruption and or malfunctioning of any telecommunication or electronic equipment or any programs The Manufacturers obligations under this Warranty are limited solely to repair and or replace at the Manufacturer s discretion any Product or part thereof that may prove defective Any repair and or replacement shall not extend the original Warranty period The Manufacturer shall not be responsible for dismantling and or reinstallation costs To exercise this Warranty the Product must be returned to the Manufacturer freight pre paid and insured All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty This warranty shall not be modified varied or extended and the Manufacturer does not authorize any person to act on its behalf in the modification variation or extension of this warranty This warranty shall apply to the Product only All products accessories or attachments of others used in conjunction with the Product including batteries shall be covered solely by their ow
21. ference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Due to FCC requirements in the U S A and IC in Canada transmission power is limited This limited power output should provide a maximum operating range of 400 feet in open space This range may be reduced further when operating within buildings or around other obstructions to R F signals Other operating frequencies as approved for use in other parts of the world have a higher allowed transmission power which can result in greater range CUSTOMER PREMISES EQUIPMENT AND WIRING The REN is used to determine the number of devices that may be connected to a telephone line Excessive RENs on a telephone line may re
22. it can be located on a table or on a wall In both cases the Unit should be near an electrical outlet and phone line Mounting on a Table Fig 4 Insert the AMBER SELECT AMBER SELECT stand into the holes see illustration below and place the AMBER SELECT AMBER SELECT on a table Figure 4 Table Stand Mounting Note The table stand can be easily disassembled by inserting a screwdriver into the rib space of the stand and with the screwdriver pulling the stand away from the unit USING YOUR SYSTEM Using your AMBER SELECT AMBER SELECT Your AMBER SELECT AMBER SELECT is the communication center of your system When your pendant transmitter or optional fall detector smoke detector signals the AMBER SELECT AMBER SELECT the AMBER SELECT AMBER SELECT contacts your Monitoring Center or private phones to report the emergency event Your AMBER SELECT AMBER SELECT includes the following buttons EMERGENCY E When pressed an emergency alarm is reported to the Monitoring Center or to private phones and a two way voice communication is opened between the unit and the Monitoring Center CALL J When pressed a non emergency message is reported to the Monitoring Center and a two way voice communication is opened between the unit and the Monitoring Center CHECK J This button should be pressed to Answer Incoming Calls When the phone rings
23. ive about your system Because the call is non emergency call there might be a delay before the Monitoring Center representative responds As long as the display AMBER SELECT only shows CALL WAS PRESSED you do not need to press the button again A representative will begin speaking to you shortly Remote control Functionality Both the central station and any person to whom the AMBER SELECT AMBER SELECT unit is dialing can perform a number of actions using the AMBER SELECT AMBER SELECT unit as follows and open a two way voice by telephone Pressed Performs button 2 Acknowledge private report 9 99 sequence ends of voice session after emergency report 1 Half duplex speaker ON microphone OFF 3 Half duplex microphone ON speaker OFF 6 Automatic full duplex 4 Increase speaker volume 7 Decrease speaker volume 5 Trouble announcement 8 Trouble stop sequence toggles USER TEST MODE ON OFF 0 Not in use Usin the Amber select AMBER SELECT _ Intrusion Alarm System Optional You can perform the following functions in the AMBER SELECT AMBER SELECT alarm system e Arm the system in Away mode e Disarm the system e Disarm the system after alarm activation e View the cause of the alarm activation You can arm disarm the system using either the Amber controller or a Power Code transmitter MCT 201WP To arm the system by the AMBER SELECT A
24. n warranty if any The Manufacturer shall not be liable for any damage or loss whatsoever whether directly indirectly incidentally consequentially or otherwise caused by the malfunction of the Product due to products accessories or attachments of others including batteries used in conjunction with the Products This Warranty is exclusive to the original Purchaser and is not assignable This Warranty is in addition to and does not affect your legal rights Any provision in this warranty which is contrary to the Law in the state or country were the Product is supplied shall not apply Warning The user must follow the Manufacturer s installation and operational instructions including testing the Product and its whole system at least once a week and to take all necessary precautions for his her safety and the protection of his her property 1 08 w E E E Product Recycling Declaration For information regarding he recycling of this product you must contact the company from which you orignially purchased it If you are discarding this en you must ensure that it is returned as identified by your supplier This product is not to be thrown away with BCE ha D 301438
25. ndant transmitter can be activated by simply pushing its red button Once pushed a signal is sent from the pendant transmitter to the AMBER SELECT AMBER SELECT and the red LED on the pendant transmitter illuminates The AMBER SELECT AMBER SELECT then calls the Monitoring Center or a private phone and opens a two way voice communication between the user and the Monitoring Center or the private phone If your phone is ringing pressing the pendant s red button once will answer the incoming call You can then talk over the unit s speakerphone To end the speakerphone call and hang up simply press the pendant button again Neckband You can wear the pendant transmitter using the neckband Slip the tab on the neckband into the slot on the pendant transmitter and fasten the tab Optional Wristband Your pendant transmitter can also be used with an optional wristband To make the pendant transmitter wristband smaller slide the pendant transmitter towards the buckle To make the wristband larger slide the pendant transmitter away from the buckle Calling for Emergency Assistance If you need emergency assistance press the button on your pendant transmitter or press the large red EMERGENCY button 7 on your AMBER SELECT AMBER SELECT If you press the EMERGENCY button 2 on the AMBER SELECT AMBER SELECT the display AMBER SELECT only shows EMERGENCY BUTTON WAS PRESSED The AMBER SELECT AMBER SELECT calls your
26. odically this must be performed in a qualified testing laboratory to ensure their serviceability Replace batteries as required Make sure that everyone understands the escape plan and is able to recognize the sound emitted from the smoke alarm Verify that the escape routes are clear and that doors and windows can be opened easily If windows or doors in your home have security bars make sure that the bars have quick release mechanisms on the inside which in the event of an emergency can be opened immediately Quick release mechanisms do not compromise your security but increase the likelihood of safely escaping a home fire Practice the escape plan at least twice a year It is important that all members of the family participate especially children and grandparents Allow children to master the fire escape planning procedure before holding a fire drill at night while they are asleep The objective here is to perform a fire drill and not to frighten the children so informing the children of the fire drill before they go to bed can be as effective as a surprise drill If children or others do not awaken promptly to the sound of the smoke alarm or if there are infants or family members with mobility disabilities make sure that someone is assigned to assist them in the fire drill and in the event of a real life emergency Agree on an outside meeting place where everyone can meet once safely out of the house premises Remember to get out of the hous
27. rameters If the Zone is still opened after the system is in Arm state this zone is automatically bypassed until disarming and rearming of the system The Amber if programmed emits internal siren Speaker type sounds and announces that it is dialing the Central Station or private phones Disarm can be performed in one of two ways via the remote transmitter this can be performed outside the protected area or press and hold the CHECK button on the unit for 3 seconds if pre defined when programming the unit Reminders will be active e Detector Name the AMBER SELECT AMBER SELECT will announce the detector type for example pendant fall detector smoke detector and the detector s zone number e Signal Strength 3 beeps indicate strong signal strength 2 beeps indicate good signal strength 1 beep indicates poor signal strength no beeps indicate that the AMBER SELECT AMBER SELECT has failed to measure the signal strength for that transmission Pendant transmitter Test Regular manual testing of your pendant s is an optional feature If your installer has enabled pendant tests then at the scheduled time the unit will announce and display AMBER SELECT only Please Test Your Pendant The panel will also display AMBER SELECT only Press Your Pendant along with the pendants name You must then press the pendant transmitter whereby the unit will announce and display AMBER SELECT only Test Complete
28. re purchased Step 2 Connect the Unit to your Telephone Line Figures 3a and 3b The AMBER SELECT AMBER SELECT communicates with your Monitoring Center through your telephone line 1 Locate the phone jack on your wall where you want to connect your AMBER SELECT AMBER SELECT If a phone is already plugged into that jack unplug it and connect it to the PHONE connector on the back of the AMBER SELECT AMBER SELECT Your telephone will still function normally 2 Connect the wide end RJ 45 of the phone cord to the Wall Jack on your AMBER SELECT AMBER SELECT Plug the narrow end RJ 11 of that phone cord into the phone jack on your wall The AMBER SELECT AMBER SELECT is now connected to your telephone line Note Be aware of other phone line services such as DSL If DSL service is present on the phone line you must install a filter See Figure 3 for proper installation POWER CORD SAFETY CATCH LELLLELE TURN THE SAFETY CATCH SCREW IN THE DIRECTION SHOWN 77 3 a Phone Line RS232 x10 i Fe AMBER LA WN S SELECT OLNI i only Figure 3a For advanced phone connections see last page 4 Note The safety catch is optional can be purchased upon request n gor oca we se Figure 3b Power Telephone and Tel line Connection Step 3 Connect Power to AMBER SELECT AMBER SELECTX Fig 3 During normal operation your AMBER SELECT
29. smitter MCT 201 WP e Fully supervised indoor PowerCode gas detectors MCT 440 MCT 441 and carbon monoxide gas detector MCT 442 Fully supervised indoor PowerCode flood detector MCT 550 Fall detector pendant transmitter MCT 241MD supplied with clip to be attached to the user belt or shirt pocket e Wristband supplied for MCT 212 e Pet Immune PowerCode wireless PIR motion detector NEXT K9 85 e Supervised PowerCode magnetic contact transmitter MCT 302 e Microprocessor controlled wireless repeater MCX 600 The system unit is shown in Figure 1 Note All of the listed transmitters have a PERS suffix In addition the txid code of each transmitter is printed on the packaging Note PowerCode refers to Visonic s proprietary communications protocol which makes use of unique ID codes AMBER SELECT AMBER SELECT MCT 212 T MCT 211 MCT 425 MCT 550 MCT MCT 442 440 441 MCT 241MD MCT 201 WP MCX 60 D 301438 DIRECT LINK 1 i e SPEAKER BUTTONS 7 gapeease RW 00000000 DISPLAY 23598989 AMBER SELECT 33382893 ONLY 96999999 CHECK b A JH 33888888 CALL BUTTON j J 383E BUTTON Y 1 Ooeseoes Fii STATUS EMERGENCY POWER TROUBLE LED BUTTON LED LED Figure 1 Front View PENDANT TRANSMITTER TEL LINE PUBLIC UP TO 29 i WIRELESS DEVICES MAN DETECTORS i TRANSMITTERS SMOKE DETECTOR
30. sult in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five To be certain of the number of devices that may be connected to a line as determined by the total RENs contact the local telephone company The REN of an alarm system is part of the product identifier that has the format US VSOALOOBAMBER SELECT AMBER SELECT Note For whole house line seizure with DSL service present on the phone line you must install a filter It is suggested to use the DSL alarm filter model Z A431PJ31X manufactured by Excelsus Technologies or ints equivalent This filter simply plugs into the RJ 31X jack and allows alarm reporting without breaking the internet connection DSL FILTER RJ 31X CORD E TO LINE JACK For locations with DSL service Customer Information The required customer information is provided in the User Guide manual 1 This equipment wireless emergency response system model AMBER SELECT AMBER SELECT complies with Part 68 of the FCC Rules and the requirements adopted by the ACTA On the bottom panel of this equipment is a label that contains among other information a product identifier in the format US VSOALOOBAMBERNA If requested this number must be provided to the telephone company D 301438 11 2 This equipment is designed to be connected to the telephone network using RJ11 connector which complies with Part
31. upload Remote control by telephone Remote diagnostic and event log Visual and audible announcements Physical Properties Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 140 F 20 C to 60 C Size 9 13 16 x 7 1 4 x 2 5 16 in 248 x 185 x 55 mm Weight 3 Ib 1 35 kg Color Off white Note The product supports all standard monitoring center receivers such as Osborne Hoffman 3 SYSTEM SETUP To set up your system follow the steps below After you complete steps 1 through 5 your system will automatically call the Monitoring Center to guide you through the rest of the set up Step 1 Select Unit Location If possible select a central location in your home for the Unit This location should be in the area where you spend most of your time The location should also enable an optimal signal reception for pendants and smoke detectors The Unit can be placed on a table desk or counter It also can be mounted on a wall Make sure that the location you have selected is near an electrical outlet and a phone jack Note Certain remote areas of your residence may lie outside the reception range of the AMBER SELECT AMBER SELECT resulting in the unit not being able to receive transmissions directly In this case a Repeater MCX 600 can be used to increase the AMBER SELECT AMBER SELECT reception range For further details please contact the company from where the products we