Home
Yokogawa LL50A Software Package Installation Manual
Contents
1. ee P X Don t run the program unless you know where it s from or you ve used it before E E english LL50A Setup msi Unidentified Publisher gt Cancel I don t know where this program is from or what it s for gt Allow I trust this program I know where it s from or I ve used it before Details User Account Control helps stop unauthorized changes to your computer 15 Installation begins When installation is completed a confirmation message appears Click Close The following icons are appeared on the desktop Setting Tool Network Profile Tool o 4 O 4 At this point you have completed installing the LL50A parameter setting software in Windows Vista For installation of LL50A Parameter Setting Software in windows XP follow the message given in each dialog box E Verifying Installation of LL50A Parameter Setting Software From the Start menu of Windows point to All Programs then UTAdvanced and verify that the Setting Tool and the Network Profile Tool is registered E Uninstalling LL50A Parameter Setting Software From the Start menu of Windows select Control Panel gt Programs and Features 1 gt LL50A and uninstall it In Windows Vista the User Account Control screen appears Click Allow The LLSOA is uninstalled 1 In Windows XP Add or Remove Programs YOKOGAWA YOKOGAWA ELECTRIC CORPORATION Network Solutions Business Division 2 9 32 Naka cho Musas
2. N A message appears to warn that the software you are installing has not passed Windows Logo testing Click Continue Anyway 70 Copying of the virtual COM port driver begins When installation is completed a confirmation message appears Click Finish At this point you have completed installing the driver software in Windows XP IM 05P05A01 01EN page 1 2 E Verifying Installation Operating procedures and screens in Windows Vista 7 From the Start menu of Windows select Control Panel gt Device manager Note 1 From the Start menu of Windows select Control Panel gt System and Maintenance gt Device manager if the control panel s display method is Control Panel Home Note 2 In Windows XP from the Start menu of Windows select Control Panel gt System gt Hardware gt Device manager and verify the steps 3 and 4 2 In Windows Vista the User Account Control screen appears Click Continue 3 Verify that the virtual COM port driver 1 YOKOGAWA USB Serial Port COMn is displayed under Ports COM amp LPT as COM port and the USB device driver 2 YOKOGAWA USB Serial Converter A1053UR is displayed under Universal Serial Bus controllers rm J Device Manager File Action View Help i amp F Ports COM amp LPT a 4 Printer Port LPT1 Processors I Security Devices 8 X Sound video and game controllers lt gt Storage controllers g System devices g Uni
3. Read Me First UT Avance Parameter Setting Software with Ladder Program Building Function and Network Profile Creating Function IM 05P05A01 01EN Installation Manual YOKOGAWA Yokogawa Electric Corporation 2nd Edition Nov 2009 This manual describes the installation uninstallation of LL50A Product Registration Thank you for purchasing YOKOGAWA products YOKOGAWA provides registered users with a variety of information and services Please allow us to serve you best by completing the product registration form accessible from our homepage http www yokogawa com ns reg Contents Introduction 1 Safety Precautions 2 Operating Environment 3 Installing USB Converter Driver Software 4 Installing LL50A Parameter Setting Software Introduction Thank you for purchasing the UTAdvanced Series Digital Indicating Controller and LL50A Parameter Setting Software This manual describes the installation uninstallation of LL50A Please read though this users manual carefully before using the product For the function and operating method of LL50A Parameter Setting Software see LL50A Parameter Setting Software User s Manual CD ROM For details of each function refer to the electronic manual contained in the provided CD ROM E Checking the Contents of the Package Before using the product refer to the table of Model and Suffix Codes to make sure that the delivered product is consistent with the m
4. all this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information v See details 9g The message Installing driver software appears 10 Copying of the USB device driver for the dedicated cable begins When installation is completed a confirmation message appears Click Close 17 Installation of the virtual COM port driver begins continuously Since the CD has already been inserted click Next Insert the disc that came with your USB Serial Port If you have the disc that came with your device insert it now Windows will automatically search the disc for driver software 7 2 The message Installing driver software appears 13 The Windows Security screen appears Click Install this driver software anyway R Windows Security gt Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information v See details 14 The message Installing driver software appears 15 Copying of the virtual COM port driver begins When installation is completed a confirmatio
5. ancel lt Back Note1 If you chose Complete go to the procedure 13 Note2 If you chose Custom continue the procedure as follows Choose each installation method 1 of LL50A or Profile and Setting then click Next HS e Custom Setup Select the way you want features to be installed Click on the icons in the tree below to change the way features will be installed amp Will be installed on local hard drive 1 The explanation of the function aau shi g Tool Will be installed on local hard drive 2 J Profile 2 EN Md I S etting 38 Entire feature will be installed on local hard drive EM Setting 1 b Feature will be installed when required 98 Entire feature will be installed on local hard drive x Entire feature will be unavailable Feature will be installed when required X Entire feature will be unavailable Cancel l lt Back 1 Profile is to install Network Profile Tool Setting is to install Parameter Setting Tool 1 On the LL50A select Entire feature will be installed on local hard drive 2 On the Profile and Setting select either Will be installed on local hard drive or Entire feature will be unavailable 13 The Confirm Installation screen appears Click Next 14 The message Installing LL50A appears The User Account Control screen appears Click Allow r User Account Control
6. e installation location such as C Enter the full directory path e When NET Framework 3 5 SP1 is not installed on Windows XP Windows Vista personal computer NET Framework 3 5 SP1 is installed to start LL50A e When reinstalling LL50A uninstall the installed LL50A first and then reinstall LL50A CAUTION E Installing LL50A Parameter Setting Software Operating procedures and screens in Windows Vista 7 Start Windows 2 Insert the CD of LL50A into the CD ROM drive The start up screen appears automatically vigilantplant If you use the USB interface install the USB driver on your PC For details refer to the installation manual YOKOGAWA gt All rights reserved copyright 2009 Yokogawa Electric Corporation Quit Note If the start up screen does not appear automatically and the AutoPlay screen appears click Run startup exe to display the start up screen 3 Click LL50A Installation 4 When NET Framework 3 5 SP1 is not installed on a personal computer the license agreement for installing it appears Click Accept tC LLSOA Setup For the following components NET Framework 3 5 SP1 Please read the following license agreement Press the page down key to see the of the agreement MICROSOFT SOFTWARE SUPPLEMENTAL LICENSE TERMS MICROSOFT NET FRAMEWORK 3 5 SP1 FOR MICROSOFT WINDOWS OPERATING SYSTEM View EULA for printing Do you accept the terms of the pending License Agreement f y
7. enu of Windows select Control Panel gt Programs and Features Note In Windows XP from the Start menu of Windows select Control Panel gt Add or Remove Programs and uninstall the driver software Select YOKOGAWA USB Serial Converter Drivers A1053UR and click Uninstall Change 4 In Windows Vista the User Account Control screen appears Click Continue Follow the instructions appearing on screen Verify that the dedicated cable is unplugged Click Continue FTDI Uninstaller v3 0 If your USB device is connected please unplug it now Press Continue to uninstall the drivers or Cancel to quit Continue 6 Follow the instructions appearing on screen Click Finish At this point you have completed uninstalling the driver software 4 Installing LL50A Parameter Setting Software e Logon in Windows XP Log on using the user name of Administrators group The program does not start normally if the user name not belonging to the Administrators group is used for loggong on e In Windows Vista install the software as an administrator e In Windows Vista do not set LL50A user file save directory in Program Files folder The LL50A will not work properly Also if LL50A user file save directory is set in Program Files folder on Windows XP personal computer do not upgrade its OS to Windows Vista e Before installing LL50A Setting Software quit all running applications e Avoid entering just the drive as th
8. hino shi Tokyo 180 8750 JAPAN YOKOGAWA CORPORATION OF AMERICA Head office and for product sales 2 Dart Road Newnan Georgia 30265 USA YOKOGAWA EUROPE B V Headquarters Euroweg 2 3825 HD Amersfoort THE NETHERLANDS www yokogawa com ns IM 05P05A01 01EN page 2 2
9. his license agreement carefully If you agree select I Agree Click Next License Agreement Please take a moment to read the license agreement now If you accept the terms below click I Agree then Next Otherwise click Cancel LICENSE AGREEMENT FOR PACKAGE SOFTWARE PRODUCT ATTENTION Please read this LICENSE AGREEMENT hereinafter referred to as the Agreement carefully before installing this package software nrodiict af Yakanawa Flectric Carnoration hereinafter gt I Do Not Agree Agree Cancel lt Back Note If Do Not Agree is selected you cannot install the LL50A Click Cancel 17 The Select Installation Folder screen appears Select Everyone or Just me Click Next Note When you install the LL50A after Everyone is selected even if other users log in it is possible to start LL50A from the Start menu gt Programs menu When you install the LL50A after Just me is selected even if other users log in LL50A is not displayed in the Programs 72 The Setup Type screen appears Select Complete and click Next We recommend choosing Complete Eam E A Choose Setup Type Choose the setup type that best suits your needs a Complete All program features will be installed Requires most disk space il a Custom a Allows users to choose which program features will be installed and where they will be installed Recommended for advanced users C
10. ick Locate and install driver software recommended posal Sees a Windows needs to install driver software for your USB Serial Converter Ask me again later Windows will ask again the next time you plug in your device or log on Don t show this message again for this device Your device will not function until you install driver software Cancel 4 The User Account Control screen appears Click Continue i User Account Control ee e Windows needs your permission to continue If you started this action continue Device driver software installation i Microsoft Windows User Account Control helps stop unauthorized changes to your computer The Found New Hardware screen appears Since the CD has already been inserted click Next Insert the disc that came with your USB Serial Converter If you have the disc that came with your device insert it now Windows will automatically search the disc for driver software Next Cancel 6 The message Searching disc for software appears FA The message Installing driver software appears 8 The Windows Security screen appears Click Install this driver software anyway amp 3 BI Windows Security ify the publisher of this driver software gt Don t install this driver software You should check your manufacturer s website for updated driver software for your device Inst
11. n message appears Click Close At this point you have completed installing the driver software in Windows Vista E Installing USB Converter Driver Software in Windows XP 7 Start Windows 2 Insert the CD of LL50A into the CD ROM drive The start up screen appears automatically 3 Connect the connector of the dedicated cable to the USB communication port ofa personal computer This automatically starts up the Found New Hardware Wizard Select No not this time Click Next Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looki i joking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy indows connect to Windows Update to search for Yes this time only Yes now and every time connect a device No not this time Click Next to continue Select Install the software automatically Recommended Click Next A message appears to warn that the software you are installing has not passed Windows Logo testing Click Continue Anyway M A Copying of the USB device driver for the dedicated cable begins When installation is completed a confirmation message appears Click Finish D Installation of the virtual COM port driver begins continuously Select No not this time Click Next N Select Install the software automatically Recommended Click Next SS amp
12. odel and suffix codes you ordered Also make sure that the following items are included in the package Model and Suffix Code Suffix code Parameter Setting Software with Ladder Program Building Function and Profile Creating Function p00 Always 00 Parameter Setting Software USB converter driver CD ROM Parts No L4502XH x1 Dedicated cable Parts No A1059UR and dedicated adapter Parts No L3502LP x1 LL50A Installation Manual this document ccccceeeeeeeceeeeeeeeeeeeeeeeeeees x1 A3 size Users Manual CD ROM a cccetecerccessns5cnnstccensncaanateneccdiepeneunendiacaensdabbizecobbaes x1 1 Safety Precautions A The following symbol is used on the instrument It indicates the possibility of injury to the user or damage to the instrument and signifies that the user must refer to the users manual for special instructions The same symbol is used in the user s manual on pages that the user needs to refer to together with the term WARNING or CAUTION Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates precautions that should be taken to prevent such occurrences CAUTION Note Identifies important information required to operate the instrument m CD Handling Guideline Note e While the CD is being accessed do not remove the CD from the CD ROM drive cut the power to the PC or reset the compu
13. onging to the Administrators group is used for loggong on e In Windows Vista install USB converter driver software as an administrator e Avoid entering just the drive as the installation location such as C Enter the full directory path e Before installing USB converter driver software quit all running applications e When reinstalling USB converter driver software uninstall the installed USB converter driver software first and then reinstall USB converter driver software CAUTION E Installing USB Converter Driver Software in Windows Vista 7 Start Windows 2 Insert the CD of LL50A into the CD ROM drive The start up screen appears automatically vigilantplant If you use the USB interface install the USB driver on your PC For details refer to the installation manual YOKOGAWA Aillrights reserved copyright 2009 Yokogawa Electric Corporation Quit Note If the start up screen does not appear automatically and the AutoPlay screen appears click Run startup exe to display the start up screen ga DVD RW Drive E LLSOA E Always do this for software and games Install or run program EA Run startup exe sa Publisher not specified General options A Open folder to view files using Win Windows Explorer Set AutoPlay defaults in Control Panel 3 Connect the connector of dedicated cable to the USB communication port of a personal computer The Found New Hardware screen appears Cl
14. ou choose Dont Accept install will close To install you must accept this agreement The message Copying required files appears And then the message Installing NET Framework 3 5 SP 1 appears Installing NET Framework 3 5 SP1 6 The User Account Control screen appears Click Continue User Account Control A A program needs your permission to continue If you started this program continue Acer dotnethS5setup exe i Microsoft Corporation User Account Control helps stop unauthorized changes to your computer FA The message Please wait while Setup configures the components appears Microsoft Windows a as Please wait while Setup configures the components This might take several minutes Setup must reboot before proceeding Choose Yes to reboot now or No to manually reboot later Details gt gt JE LLSOA Welcome to the LL50A Setup Wizard The installer will guide you through the steps required to install LL504 on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel 10 The License Agreement for Package Software Product appears Read t
15. ter e Please store your original CDs carefully Install the program on your hard disk and run it from your hard disk during actual use 2 Operating Environment PC Applicable OS Windows XP Professional with Service Pack 2 or later Windows Vista Business with Service Pack 1 Only the 32 bit version of each of the above OSs NET Framework 3 5 installed Recommended CPUs Pentium 4 Processor 2 4 GHz or higher 3 0 GHz or higher in Windows Vista Business Pentium D Processor 2 6 GHz or higher Pentium Core 2 Duo Processor 1 8 GHz or higher Pentium Dual Core Processor 1 6 GHz or higher Recommended Main Memory Windows XP Professional 512 MB or more Windows Vista Business 2 GB or more Hard disk space Program storage capacity 100 MB or more NET Framework 3 5 SP1 storage capacity 620 MB or more Display 1024 x 768 pixels or more Color 256 or more colors Communication port For communication with a dedicated cable use the USB port one channel For communication via an RS 485 communication terminal use an RS 232C port An RS 232C RS 485 converter is required Model ML2 is recommended For Ethernet communication use 10BASE T 100BASE TX CD ROM drive One required for installation Printer Paper size Letter or A4 required for printing 3 Installing USB Converter Driver Software e Logon in Windows XP Log on using the user name of Administrators group The program does not start normally if the user name not bel
16. versal Serial Bus controllers oJ Generic USB Hub g Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB2 Enhanced Host C v USB Composite Device USB Mass Storage Device USB Root Hub USB Root Hub USB Root Hub i USB Root Hub USB Root Hub E E D 6 W annGnannnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 4 The COM port number assigned to the dedicated cable can be verified by the port number displayed in 1 YOKOGAWA USB Serial Port COMn of Device Manager see the step 3 To change the COM port number double click 1 select Port Settings tab of Properties screen and click Advanced Change the COM port number in the Advanced Settings for COMn screen i 3 Properti myx YOKOGAWA USB Serial Port COM3 Properties a Port Settings Driver Details Bits per second so Data bits Boo SS Parity None tsi Stop bits 1 X Flow control None Advanced Restore Defaults E Uninstalling USB Converter Driver Software Operating procedures in Windows Vista Unplug the dedicated cable if it is connected to a personal computer CAUTION 7 Unplug the dedicated cable if it is connected to a personal computer From the Start m
Download Pdf Manuals