Home

QA65B/QA68B Extension Base Unit User`s Manual

image

Contents

1. Load the module into the base unit by pushing it in the Module direction of arrow connector Check if the hook of module is securely inserted in the module fixing hole A in the base unit Two module oo fixing Module fixing hole B projections Complated Base unit ide Module mounting screw M4x 0 7 12 1 To fix the module be sure to insert the module fixing projection into the module fixing hole B If the module is forcibly fixed without insertion the pins in the module connector may be bent or damaged 2 When the base unit is used at locations where there are especially large vibration and or shock screw the module to the base 12 2 Removal of module Base unit Module fixing hole A Module connector Push Hold the module with both hands and push the hook latch at the top of module While pushing the hook latch pull the module toward you Lift upwards and remove the module fixing projections from the module fixing hole B Completed Y a To remove the module be sure to disengage the hook from the module fixing hole A and then remove the module fixing projections from the module fixing hole B If the module is forcibly removed the hook or module fixing projections will be damaged 13 6 EXTERNAL DIMENSIONS The external dimensions of the QA60B are shown below 1 The external dimensions of the QA68B
2. MITSUBISHI ELECTRIC QA65B QA68B Extension Base Unit User s Manual Thank you for purchasing the Mitsubishi programmable controller MELSEC Q series Prior to use please read this and relevant manuals thorougly to fully understand the product QA65B U MELSEE Q pener Mitsubishi Programmable CODE Controller IB NA 0800157 E 1509 MEE 2000 MITSUBISHI ELECTRIC CORPORATION CONDITIONS OF USE FOR THE PRODUCT 1 Mitsubishi programmable controller the PRODUCT shall be used in conditions i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT 2 The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT Prohibited Applica
3. 2x9 M4 screws 4 6 installation hols Base Cover for mosule installation M5 mounting screw Hand Nour wen i i me im hold in l a E 200 0 3 250 3 O 5 L Tea 446 0 3 466 F Unit mm 2 The external dimensions of the QA65B Base cover 2x6 M4 screws 4 6 installation hols for mosule installation M5 mounting screw 250 Unit mm WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Country Region Sales office Tel USA Brazil Germany UK Italy Spain France Czech Republic Poland Russia Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Tel 1 847 478 2100 MELCO TEC Representacao Comercial e Assessoria Tecnica Ltda Av Paulista 1439 cj74 Bela Vista Sao Paulo CEP 01311 200 SP Brazil Tel 55 11 3146 2200 Mitsubishi Electric Eur
4. Extension base unit for module z gt installation corresponding to the oo amp Q68B Q series oo Connect the Q50B Q60B with oo lel the main base unit and the last Q50B Q60B 16 17 18 19 20 21 22 23 i y Extension base unit for module 2 gt installation corresponding to the oo S QA1S68B AnS series SE le Connect the QA1S6LB with Bej tt the main base unit and the last Q50B Q60B or QA1S6LB ao 24 25 26 27 28 29 30 31 Extension base unit for module on 3 Et installation corresponding to the A oo series so QA68B oo 8 Connect the QA6LIB with the le main base unit and the last Q50B Q6LB QA1S6LB or QA6LB 2 2 List of configuration devices The following table lists the mountable modules on the QA6OB extension base unit Module Power module Type A61P A61PN A62P A63P A68P A61PEU A62PEU Remarks Input module AX10 AX11 AX11EU AX20 AX21 AX21EU AX31 AX31 S1 AX40 AX41 AX41 S1 AX42 AX42 S1 AX50 S1 AX60 S1 AX70 AX71 AX80 AX80E AX81 AX81 S1 AX81 S2 AX81 S3 AX81B AX82 Output module AY10 AY10A AY11 AY11A AY11E AY11AEU AY11EEU AY13 AY13E AY13EU AY15EU AY22 AY23 AY40 AY40A AY41 AY42 AY42 S1 AY42 S2 AY42 S3 AY42 S4 AY50 AY51 AY51 S1 AY60 AY60S AY60E AY70 AY71 AY72 AY80 AY81 AY82EP 1 O module A42XY AH42 High speed counter module AD61 AD61S1 Analog digital conversion module A68AD A68AD S2 A68ADN A616AD Di
5. Manual number Revision September 2015 IB NA 0800157 E Combine the Japanese manual IB 0800157 with the English manual IB 0800158 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2000 MITSUBISHI ELECTRIC CORPORATION A 3 CONTENTS xt OVERVIEW SPECIFICATIONS PART NAMES AND SETTING a cccccsccssccsiceciccentetesssthseasrerentesetsessnscateeeneensstens 6 MOUNTING AND INSTALLATION EXTERNAL DIMENSIONS 1 1 Overview 1 2 Included Parts SYSTEM CONFIGURATION neee A e ad 2 2 1 System Configuration c cccccecscceeseesseeeeeeeeeeeseeeeeeeeseeeeeaeeseeeseaeeeeaeeaee 2 2 2 List of configuration devices AI Pat Names Airne EE AA E e A R eee 6 4 2 Extension Stage Number Setting 5 1 Modille Installation ccc ccc ccc nim MMs ceca eae aaie 8 5 2 Precautions for installing base unit 2 0 2 0 eceeeceeeeeeeeeeceeeeteeeeeeeeeateeee 9 5 3 Installation and removal of modules A 4 1 OVERVIEW 1 1 Overview This User s Manual describes the specifications configuration devices names and settings of each part and mounting and installation of the QA650B extension base unit QA68B extension ba
6. one interrupt module is valid which can be chosen from QI60 A1SI61 Al61 or Al61 S1 3 SPECIFICATIONS The QA6LIB performance specifications are given below Number of I O modules connected 5 8 Applicable modules A series module 5VDC internal current consumption 0 117A 0 117A Weight 1 60kg 2 00kg 4 PART NAMES AND SETTING The names of and settings for each QA6LB part are explained in this section 4 1 Part Names The names of each QA6LIB part are explained below Mm W Expansion cable connector Applicati Aconnector for signal transmission with the basic base module or the other expansion base module Connects the expansion cable Do not remove the supplied connector cover Base cover PCB surface protection cover Stage number setting connector A used to set the stage numbers of the expansion base modules Refer to section 4 2 for the setting procedure Module connector Connector for mounting power supply unit input output unit and special function module Mount the dustproof connector cover blank cover unit AG60 or dummy unit AG62 on the connector in the spare spaces with module connected Module fixing hole Cut out to accept
7. projection and hook at rear of modules Screw hole for fastening modules A screw hole used for fastening a module to the base M4 screw Base module installation hole A hole used for mounting the base module to a panel such as a control panel 4 2 Extension Stage Number Setting The method of setting the QA60B stages is explained below Remove the base cover from the expansion base module Select the stage number from 1 to 7 in the connector PIN1 loaction between the expansion cable connectors IN and OUT Then insert a connector pin into the approprate stage number a CON11 CON10 Reattach the base cover to the expansion base module and fasten the screws Tightening torque 36 to 48N cm Completion Stage number setting for expansion base modules Extension stage number setting st nd rd th th th th 15 stage 2 stage 3 stage 4 stage 5 stage 6 stage 7 stage Stage number setting connector setting 1 To set the stage number setting connector select the appropriate number from 1 through 7 in ascending order according to the number of expansion modules 2 Do not assign the same stage number to several modules or skip any stage numbers Otherwise improper I O operation results 3 The expansion stage number is factory set to 1 5 MOUNTING AND INSTALLATION 5 1 Module Installation This section
8. 22 3030 Setsuyo Enterprise Co Ltd 6F No 105 Wugong 3rd Road Wugu District New Taipei City 24889 Taiwan R O C Tel 886 2 2299 2499 Mitsubishi Electric Automation Korea Co Ltd 3F 1480 6 Gayang Dong Gangseo Gu Seoul 157 200 Korea Tel 82 2 3660 9530 Mitsubishi Electric Asia Pte Ltd Industrial Division 307 Alexandra Road Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2308 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Soi Serithai 54 T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2906 3238 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Indonesia Tel 62 21 663 0833 Mitsubishi Electric India Pvt Ltd 2nd Floor Tower A amp B Cyber Greens DLF Cyber City DLF Phase lll Gurgaon 122002 Haryana India Tel 91 124 463 0300 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road PO BOX11 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permi Specifications subject to chan
9. describes the precautions to handle the CPU I O special function power supply and base module 1 Do not drop or apply a strong impact to the module housing memory card terminal block connectors and pin connectors 2 Do not remove the PC board of the modules from housing Otherwise malfunctions may result 3 When using the expansion base module QA6 B be sure to install the power supply module Although the module may work without the power supply module under light load stable operation is not guaranteed 4 Limit the tightening torque for the module installation screws and terminal block screws within the following range Location of screw Tightening torque range I O module terminal block installation screw M3 36 to 48 Necm A series module installation screw M4 78 to 118 Necm I O module terminal screw M4 Power supply module terminal screw M4 98 to 137 Necm 5 2 Precautions for installing base unit 1 Unit installation position Indicates the panel top wiring z Auot or any assembly Q30B basic base QA6CB extention base 80mm or more Parallel mounting Indicates the panel top wiring duct or any assembly Basic base t 80mm or more aL 80mm or more 4 Serial mounting 1 When link module is not used 50mm or more When using 4 5mm optical fiber cable 100mm or more When using a coaxial cable 100mm or more When using 8 5mm o
10. ge without notice
11. gital analog conversion module A62DA A62DA S1 AG8DAV AG8DAI S1 A616DAV A616DAI Temperature digital conversion module A68RD3 AG8RD3N A68RD4 A68RDAN A616TD A60MX AGOMXR A6OMXRN A6OMXT AGOMXTN Interrupt module Al61 Al61 S1 ioning module AD70 AD70D AD71 AD71S1 AD71S2 AD71S7 AD72 AD75P1 S3 AD75P2 S3 AD75P3 S3 AD75M1 AD75M2 AD75M3 MELSECNET MINI S3 master module AJ71PT32 S3 AJ71T32 S3 Intelligent communication module AD51 AD51E AD51H AD51 S3 AD51E S3 AD51H S3 PC fault detection module AS91 MELSEC I OLINK module AJ51T64 B NET module AJ71B62 S3 Blanking module AG60 Dummy module AG62 A A1S conversion adapter A1ADP XY A1ADP SP 1 The dedicated commands used in the QnA and A Series program cannot be used with the Q mode CPU Replace these with FROM TO commands 2 There is a limit to the number of mountable modules Intelligent communication AD51 AD51E AD51 S3 AD51E S3 module AD51H AD51H S3 Interrupt module Al61 Al61 S1 3 The AnS series modules equivalent ones to the modules listed in the table also can be used by using the A A1S conversion adapter Example A68AD gt A1S68AD For precautions on the module replacement refer to the manual for the A A1S conversion adapter 4 In combined use of the QA1S6 B and QA6 B up to 6 intelligent communication modules can be installed 5 Only
12. ope B V German Branch Gothaer Strasse 8 D 40880 Ratingen Germany Tel 49 2102 486 0 Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB UK Tel 44 1707 27 6100 Mitsubishi Electric Europe B V Italian Branch Viale Colleoni 7 20864 Agrate Brianza Milano Italy Tel 39 039 60531 Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 AC 420 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 Mitsubishi Electric Europe B V o s Czech office Avenir Business Park Radicka 751 113e 158 00 Praha5 Czech Republic Tel 420 251 551 470 Mitsubishi Electric Europe B V Polish Branch ul Krakowska 50 32 083 Balice Poland Tel 48 12 630 47 00 Mitsubishi Electric Europe B V Russian Branch St Petersburg office Piskarevsky pr 2 bld 2 lit Sch BC Benua office 720 195027 St Petersburg Russia Tel 7 812 633 3497 Country Region Sales office Tel South Africa China Taiwan Korea Singapore Thailand Indonesia India Australia CBI Electric Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 977 0770 Mitsubishi Electric Automation China Ltd No 1386 Hongqiao Road Mitsubishi Electric Automation Center Changning District Shanghai China Tel 86 21 23
13. ptical fiber cable 130mm or more 2 20mm or more when connecting extension cable without removing adjacent modules 2 Module installing position a Install the PC in the following position to ensure ventilation for heat radiation WY U O K OY Vy gt Eaa LG Vertical position Horizontal position 3 Install the base module on a flat surface When the base module is installed on an uneven surface the PC board may be strained resulting in malfunction 4 Do not install the PC close to a vibration source such as a large electromagnetic contactor or no fuse breaker Install the PC to the separate panel or isolate it as far as possible 5 Provide the following distances between the PC and devices contactor or relay to avoid the influence of radiation noise or heat Device installed in front of the PC 100mm or more e Device installed on either side of the PC 50mm or more lt cL Wie LL im LU onm or more 50mm or more or more Contactor relay etc 11 5 3 Installation and removal of modules This section explains the installation and removal procedures of the power supply module CPU module I O module special function module etc to and from the base unit 1 Installation of module Insert the two module fizing Module fixing hole A projections two into the module fixing hole B in the base unit Base unit Module unit
14. se unit hereinafter QA6O0B Refer to the QCPU User s Manual Hardware Design Maintenance and Inspection SH 080483ENG enclosed with the main base unit for the matters not described in this manual such as the QA60B safety precautions and general specifications 1 2 Included Parts This section describes parts included with this module Product Quantity Extension base unit 1 0 number seal This manual 2 SYSTEM CONFIGURATION 2 1 System Configuration The system configuration and precautions for using the QA6OB extension base unit are described in this section 1 Extension base unit connection order When using the Q50B Q60B QA1S60B and QA6LB together connect from the unit closest to the main base unit in the order of aQa50B Q60B QA1S60B and QA6LDB 2 Setting order of the expansion stage numbers for expansion base units Expansion base units require the setting of the expansion stage numbers 1 to 7 using the stage setting connector Assign the expansion stage numbers starting from 1 to 7 to the expansion base units counting from the one which is connected to the main base unit 01234567 A gt Setting of S Q38B Main base unit extension stage Pi fe Stage setting connegtor 8 9 1011 121314 15 i il
15. tion Prohibited Applications include but not limited to the use of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property A 1 Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region A 2 REVISIONS The manual number is given on the bottom right of the cover Print date