Home
- R & J Batteries
Contents
1. 10 1 Installing driver 2 2 2 222020 0e nen nn nen en en nnnenenennnnenennenenennenenenensenenenses 48 10 2 Printing Results from PC Printer 22 2 0 0cnencncnencncensnenenenenensncncnnnes 53 10 3 Saving Results to PC 2222 2222 220 54 11 1 Limited Warranty _ m 55 11 2 Limitations of Warranty _ m 56 BESA 12PM Version PM1504 WS BESA 12PM User s Manual 1 0 Introduction 1 1 BESA 12PM Battery Electrical System Analyser The utilization of the latest advanced technologies in battery testing had enabled this Analyser to test batteries in any conditions Testing procedures are made simple with quick easy and repeatable results Test Results can be printed directly on its built in printer It can store up to 300 test Results in its memory for future references and they can also be transferred and saved in the PC for records management via an USB port link The programs consist of 1 Battery Test Analyses the battery condition using microprocessor controlled testing methods without the need of fully charging it before test The unit consumes very little current during testing hence the test can be repeated numerous times without worry of draining the battery and its res
2. Results Low charge At 3 000 rpm No load Test Whines ON lls iy Check for loose belt and tHe alternator Fig 64 R amp J Batteries Results High charge At 3 000 rpm No load Test Max lt 15 OV lt 37 15 6V Check alternator and the regulator Fig 65 Version PM1504 BESA 12PM User s Manual PSS Testing with electrical load at 2 000 RPM As more electrical accessories such as lights rear demister heater car stereos etc were used the electro motive force decreases and this will allow more amperage from the alternator to flow into the battery to compensate for the added load This test is to check the alternator s behavior during loading 7 Continue from the previous test either Fig 63 64 or 65 proceed to the next step by pressing key will enter to the display as follows Fig 66 Switch ON all electrical loads Rev engine up to 2 000 rpm Press Fig 66 Enter Hold on to this 2 000 rpm for 10 seconds and release the pedal Follow the instructions switch ON all electrical loads Head Lights Radio Rear Demister Heater etc Note Air Condition mostly mechanical load should be OFF as it sometimes slowdown the idling speed of certain cars while it is ON thereby affecting the idling speed charging results Rev the engine up to 1 500 2 000 RPM by referring to the dashboard meter then press key and maintain the engine speed for about 10 seconds a
3. Try again and follow Fig 85 the step by step instructions given Exit to Menu 15 Just press key if you need to printout the results 16 To exit the program pressing the amp key at any moment will exit and return back to the main menu screen Fig 75 8 0 Stored Results 8 1 Recalling and viewing previous Test Results To view the results of the last test BESA 12PM has to be connected to an external power source by either clamping its clips directly toa 12Volt car battery or connected to a PC via the USB port BESA 12PM As R amp J Batteries Version PM1504 BESA 12PM User s Manual XE 1 Once power up the wakeup screen will display as follows Fig 87 2 It will run through a self test and when completed it displays the Main Menu as shown Fig 88 Select Menu AV 02 04 2014 10 38 New Test Fig 88 Other System Test Stored Results Setup Menu 3 Pressing x key to scroll down to the Stored Results as shown in Fig 89 below Select Menu AV 02 04 2014 10 38 New Test Other System Test Fig 89 Stored Results 46 Setup Menu 4 Press key will proceed to the display on a list of the recorded names particulars that was keyed in earlier for you to select as an example shown below Fig 90 BESA 12PM Version PM1504 Pa BESA 12PM User s Manual Select qPAaAvV AD8778ML C1234MN Fig 90 MR SMITH BOSCH 12V YUASA YTX7L BS 5 Select it b
4. amp J Batteries Version PM1504 BESA 12PM User s Manual OD Diode Ripple Test Switch ON all elecir ical oade Run engine up at Fig 71 idling speed Press Enter 13 Make sure the electrical loads Headlights High beams heaters etc are switched ON Important Note Do not switch ON the Air Conditioner as it may affect the results Let the engine runs at idling speed Do not Rev 14 Then press key to continue The display will show Fig 72 Diode Ripple Test At idling rpm Analysing Please wait Fig 72 SEREREE 15 After analysing the analyser will display the results Fig 73 or Fig 74 depending on the outcome Results OK Results High Ripple AC ripple test AC ripple test At idling rpm At idling rpm Max lt 0 5V 0 19V Max lt 0 5V 0 8V 40 Ripples are good Check alternator diodes Exit to Menu Exit to Menu Fig 73 Fig 74 BESA 12PM Version PM1504 Pa BESA 12PM User s Manual 16 Just press 2 key if you need to printout the results 17 To exit the program pressing the key at any moment will exit and return back to the main menu screen Fig 5 7 7 3 Grounding Test The engine body and the vehicle chassis are always connected to the battery negative terminal to provide the electrical return path grounding for all the electrical components Due to the surrounding environmental effect the surface contacts of these joints or connection
5. 3 in a loop sequence and stop it when found Press D key to move to the next or a key to move backwards to continue the key E in Note If you do not input any particulars and straight away press key to continue then the test results will not save in its memory After completion of the input press key will proceed to the next display as shown in Fig 78 below Grounding Test Clip the Black clip to engine body or the car chassis and the Red clip to the battery PI ost Fig 78 Press Enter to begin _A2 5 Now transfer the BLACK tester clip from the battery terminal to a Suitable position on the engine or chassis body leaving the RED clip still attached to the battery terminal 6 Press key again and it will starts analyzing Fig 79 7 BESA 12PM Version PM1504 BESSA 12P M User s Manual Analysing Fig 79 Please wait 8 Once it has finished analysing it will prompt you with an instruction Fig 80 stating that you have should unclamp the Black tester clip from the engine or chassis body and transfer to the battery negative terminal within 20 seconds time limit if not the testing procedure has to be repeated again as the gathered data will be lost Grounding Test Now transfer the Black clip to the battery Fig 80 H post The time limit given is 20 seconds before the memory is lost 9 Once the Black clip is clamped onto the battery terminal the Analy
6. Analyser clips onto the battery terminal posts and it will bower up and lights up the LCD display screen as shown Fig 57 Press lt 4 key and the display will show as Fig 58 below Select Menu AV Select Test AV 02 04 2014 10 38 Starter Tesi New Test Alternator Test Other System Test Grounding Test Stored Results Enter to proceed Setup Menu Fig 57 Fig 58 3 Select Alternator Test and it will proceed to the display below Fig 59 Vehicle Details VA Input lt P Move Enter to proceed 35 Fig 59 R amp J Batteries Version PM1504 BESA 12PM User s Manual BE 4 Here it let you key in the particulars e g license plate number etc To key in the alphabets or numbers keep pressing v or a key to scroll from X Y Z 0 1 2 3 in a loop sequence and stop it when found Press D key to move to the next or lt key to move backwards to continue the key in Note If you do not input any particulars and straight away press key to continue then the test results will not save in its memory After completion of the input press key will proceed to the next display as shown in Fig 60 below Alternator Test Start the car engine and keeps it running Fig 60 Then press Enter to begin Start the engine and then press key again and the screen will prompt you as shown below Fig 61 No Load Test Make sure all electrical loads are turn OFF Rev th
7. C then select Above 0 C by pressing z key and then press key Then the results will show on the LCD display Battery OK Recharge Rating 630 CCA Measured 478 CCA Fig 34 Volts WAS lat chs 5 64 mOhm Lite 64 To print out the results just press Akey on the Analyser the printer will start printing meee R amp J Batteries Version PM1504 BESA 12PM User s Manual Ey 6 2 Battery Test for Motorcycle Commercial vehicle etc To test motorcycle batteries or others it is better to test with the battery taken out from the vehicle battery compartment for better results This is mainly due to the obstruction of the wires that were attached to the battery terminals and the tester clamps may not clip properly due to lack of space at its terminals thereby may cause false test results 1 While it is on the Main Menu as shown Fig 35 Select Menu AV 02 04 2014 10 38 Fig 35 Other System Test Stored Results Setup Menu 2 Select New Test will proceed to the display below Fig 36 Vehicle Details VA Input lt gt Move Fig 36 E Enter to proceed 3 To key in the alphabets or numbers keep pressing x or a key to scroll from X Y Z 0 1 2 3 in a loop sequence and stop it when found Press b key to move to the next or 4 key to move backwards to continue the key in Note If you do not input any particulars and straight away press key to continue then the t
8. Fig 8 will initiate printing of the results of the last tested vehicle that has been stored in the memory Setup Menu Language LCD Brightness Printer Set date amp time PC Link Erase Memory 12 Fig 8 BESA 12PM Version PM1504 WE BESA 12PM User s Manual 5 5 Set Date and Time The date and time on the Analysers were set in the Factory during production Due to the differences of the Time zone in your Country you may need to set according to your local date amp time and this can be done by selecting Set date amp time with z or amp key and the press and the display shows as in Fig 10 below Setup Menu Set date amp time Language ECD Brightness 04 2014 10 38 Printer Set date amp time PC Link Erase Memory Enter to proceed Eio emit Fig 9 Fig 10 Press vy or a key to change the date and then press D to skip to the next Do this for the rest like month year and the time When the setting is done press key to save 5 6 PC Link This PC Link mode is used when you wish to connect BESA 12PM to PC to print or store the results of the last tested vehicle Once the tester is connected to the PC with the USB cable provided select PC Link as in Fig 11 with 7 key and press key will show as in Fig 12 Setup Menu AV Language LCD Brightness Printer Set date amp time PC Link Erase Memory sil ER R OR Fig 11 Fig 12 R amp J Batteries Vers
9. X Y Z 0 1 2 3 in a loop sequence and stop it when found Press D key to move to the next or a key to move backwards to continue the key in l Note If you do not input any particulars and straight away press key to continue then the test results will not save in its memory 5 After completion of the input press key will proceed to the next display as shown in Fig 20 below Regular WET Pb Pb Regular WET Pb Ca MF VRLA Ca Ca e17 AGM Flat plate AGM Spiral wound GEL cell EFB Start Stop Fig 20 R amp J Batteries Version PM1504 BESA 12PM User s Manual RB Here it will let you select the type of battery construction that you are testing Once it has been selected press key to proceed 6 The next display Fig 21 below will ask the type of application that the battery being used Application AV Automotive In Vehicle Motorcycle Outside vehicle Commercial vehicle Fig 21 Fig 22 Motor Scooter Marine Watercraft Lawn Mover Golf Cart Snowmobile 7 On the Application menu above if Automotive is selected then the display will change to as shown Fig 22 above Here it offers a selection of In vehicle This test can be performed on cars only with the battery fixed on The Analyser will test the Battery the Starter and the Alternator charging conditions of the car in an automatic one after another sequence manner It will prompt you all the way until comp
10. for nest icon Lt Left click on the icon to open the program and tl 2 splay page will show as below puporT com gt It will automatically ine a Click here to select your detect COM Port preferred language from the Test Date posom 10 different languages Customer Car Plate Reference NO Click here to put your E E Company name and address Header Footer Get Data From Analyser Print Save As Battery Model Capacity Step 6 Now link up BESA 12PM with PC by the following procedures 1 On the Main Menu page Fig 94 below select Stored Results by pressing key to highlight it and then press key Select Menu AV 02 04 2014 10 38 New Test Other System Test Fig 94 Stored Results Setup Menu 2 The display Fig 95 will show a list of the particulars that you had keyed in prior to the test Select by scrolling or A key and then press key The display will change to as shown in Fig 91 Select IVA AV AD8778ML C1234MN oe MR SMITH Fig 95 MECE BOSCH 12V YUASA YTX7L BS R amp J Batteries Version PM1504 BESA 12PM User s Manual 16 04 2014 1s a5 ADC8899L Automotive Regular Wet Pb Pb Outside Vehicle Fig 96 3 While on this display Fig 96 click on Get Data from Analyser tab on the PC and the Test Result will appear See example below COMPORT coma X 1 Battery Test State of Charge 12 49 Volt Language Engl
11. A SAE 100A 1700A CA 100A 1700A CCA 40A 600A EN 40A 600A IEC 40A 600A DIN 40A 600A JIS 40A 600A SAE 40A 600A CA 40A 600A 1 Reading Less than 8 seconds English only Stored up to 300 Test results Through USB port Thermo print head 57 5mm 0 5mm 45 0 mm O D 50 mm per second 0 C 50 C 10 gt 80 Version PM1504 ES SESA 12P M 2 0 Safety Measures A User s Manual For safety reasons read this manual thoroughly before operating the Tool Always refer to and follow the safety instructions and testing procedures provided by the car or equipment manufacturer The safety messages presented below and throughout this user s manual are reminders to the operator to exercise extreme care when using this test instrument 2 1 Safety Precautions R amp J Batteries When the engine is running it produces carbon monoxide a toxic and poisonous gas Always operate the vehicle in a well ventilated area Do not breathe exhaust gases they are hazardous that can lead to death ACAUTION To protect your eyes from propellant object such as caustic liquids always wear safety eye protection ADANGER Fuel and battery vapors are highly flammable DO NOT SMOKE NEAR THE VEHICLE DURING TESTING ACAUTION When engine is running many parts such as pulleys coolant fan belts etc turn at high speed To avoid serious injury always be alert and keep a safe distan
12. BESA 12PM Battery Electrical System Analyser User s Manual Version PM1504 R amp J Batteries Version PM1504 BESA 12PM User s Manual Table of Contents 1 1 BESA 12PM Battery Electrical System Analyser 3 1 2 SpecificationS 2 2 220n nnn enn 4 4 1 BESA 12PNK 2 0 02 20220022 nen ne nen nen n en nen nen neneenen nen nen nen neneen 9 4 2 Key FUNCtiONS 222 222 nnn sence nnn nn sense nen nnn nen nn en nen nenneennennennns 10 4 3 Functions of Individual Key 02 nennnnen nen nnnnnennen 10 5 2 Setup Menu 222 222 nnn nnn n nnn nn nnn nn nnn nen eens nnn nn nnn nnn nnn nn nen nennennnnnnn 11 5 3 LCD Brightness 2 0 0 n nnn nen n nnn n nnn nn nen n nnn n enn mmm 12 7 2 Alternator Test 20 nn nena nena nena nn nn nnn n nnn enn nena nennnennnenenennnennnes 35 Starts with No Load testing at 3 000 RPM 00 0 00 0 00 00 35 Testing with electrical load at 2 000 RPM 2 00 00 0 32 7 3 Grounding TeSt 2 222 22 nnn nnn n nn en nnn n nnn nn nnn nnn nnn nnnen nen nnnnennnn 41
13. CCA available power when fully charged The available power number is meant for comparison to its own rating In fact in this example the 120 CCA battery is failing to perform to its rating while the 90 CCA battery is still working Basing on SAE CCA test is a manufacturing process control test applicable only on new fully charged batteries It does not produce an actual value but is a PASS FAIL test It measures the discharge load in amps that a battery can supply for 30 seconds at 0 F 18 C while maintaining a voltage of 1 2 volts per cell 7 2 volts per battery or higher Thus the CCA test shows the minimum power requirement for the battery as rated which means a battery rated at 90 CCA must measure 7 2 volts or above for 30 seconds when a load of 90 amps is applied at 0 F 18 C The above methods also hold for DIN IEC JIS EN basing on its individual ratings 5 Int R Internal Resistance 28 42 mQ In normal condition the internal resistance for motorcycle batteries should fall between 4 5 mQ 65 0 mQ As for cars the internal resistance will be from 2 0 mO to 15 0 mQ As a matter of fact the higher the battery CCA readings obtained the lower the internal resistance should be 6 LIFE 69 Health This is an indication of the battery life State of Health in percentage If the falls below 60 the RESULT will display Replace and it is time to change to a new battery Explanation of the followi
14. T Battery Modet ah me NGM WET AGM Battery Model WET AGM 60 YTZ12S BS_ 4114 210 110 YTZ14S 112 230 110 YTZ14S BS_ 11 2 230 120 d G e Fig 38 3 Ifthe rating CCA is confirmeu pressing key will show Fig 39 below Input Battery Rating Increase decrease A Single digit V lt q By hundredth gt 40 CCA Fig 39 Press Enter to proceed 4 For Example lf the motorcycle battery is model YT9B4 Type AGM 120CCA as refer to the above table Fig 38 To enter the value 120 press D key will increase the original value of 40 Fig 39 by step of 100 units to 140 Likewise use 7 key to decrease the last two digits 40 to 20 by step of 5 units for each pressing See Fig 40 Increase decrease A Single digit V lt q By hundredths gt Fig 40 120 CCA Press Baer to 26 proceed Once the CCA rating of the battery is confirmed press key will start the testing process Refer to the display below Fig 41 BESA 12PM Version PM1504 Wa BESA 12PM User s Manual Analysing lease werk BERRRRE Fig 41 5 For less than 8 seconds the results of the testing will be displayed on the LCD screen Fig 42 Rating 120 CCA Measured 105 CCA Volts 12 65 V Int R 25 71 mOhm Fig 42 l Lite Sl 6 This Analyser will also takes the temperature of the battery into consideration when it has detected that the battery condition is marginal b
15. Word Files doc x Cancel Add To Test Report Header Footer Capacity After you had completed saving the first result and wish to save the next one you should press key on the Analyser to the display as shown in Fig 90 Select the_one on the list shown on the screen that you want and then press key to proceed to the particulars screen Fig 91 Again you have to click Get Data from Analyser tab on the PC to transfer the results data to be saved Disclaimer Fe All information illustrations and specifications contained in this user manual are based on the latest information available at the time of printing The right is reserved to make any changes at any time without obligation to notify any person or organization of such revisions or changes Furthermore the manufacturer or its sales agents are not liable for errors contained herein or for incidental or consequential damages including lost profits in 54 connection with the furnishing performance or use of this material This user manual tells how to use and perform the required procedures on vehicles Safe and effective use of this Analyser is very much dependant on the user following the normal practices and procedures outline in this manual 11 0 Warranty Information A BESA 12PM Version PM1504 SS BESA 12PM User s Manual 11 1 Limited Warranty This limited warranty cover defects in materials and workmanship for a period of twel
16. arranty or condition of any kind whether express or implied Any implied warranty of merchantability or fitness for use shall be limited to the duration of the foregoing limited warranty Otherwise the foregoing limited warranty is the owner s sole and exclusive remedy and is in lieu of all other warranties whether express or implied The manufacturer or any of its exclusive sales agents shall not be liable for any consequential or incidental damages or losses arising from the loss of the product All warranty information product features and specifications are subjected to change without prior notice s56 BESA 12PM Version PM1504
17. ce from these parts AWARNING Before starting the engine for testing or trouble shooting always make sure the parking brakes is firmly engaged Put the transmission in Park automatic transmission and Neutral manual transmission AWARNING Always block the drive wheels Never leave vehicle unattended while testing Version PM1504 BESA 12PM User s Manual EE Never lay tools on vehicle battery You may short the terminals together causing harm to yourself the tools or the battery ACAUTION Engine parts become very hot when engine is running To prevent severe burns avoid contact with hot engine parts AWARNING Do not wear loose clothing or jewelry while working on engine Loose clothing can get caught in fan pulleys belts etc Jewelry can conduct current and can cause severe burns if comes in contact between power source and ground ACAUTION When the engine is running be cautious when working around the ignition coil distributor cap ignition wires and spark plugs They are HIGH VOLTAGE components that can cause electrical Shock IMPORTANT Always keep a fire extinguisher readily available and easily accessible in the workshop 2 2 Other Precautions ry e This Battery Analyser is meant for testing of 12 Volts batteries only e ts operating voltage is from 9V 15V DC and should not be tested on 24V directly It will cause damage the unit For 12V x 2 batteries in series or parallel
18. charging has been completed recheck the level gt Reinstall the vent caps BEFORE recharging recharge ONLY in well ventilated areas and wear protective goggle Do NOT smoke or cause sparks or flames while the battery is being recharged because batteries give off explosive gasses gt If your battery is an AGM or a sealed flooded type do NOT recharge with current ABOVE 12 of the battery s RC rating or 20 of the ampere hour rating Gel cells should be charged over a 20 hour period and never over the manufacturer s recommended level or over 14 1 Volts DC gt Follow the battery and charger manufacturer s procedures for connecting and disconnecting cables and other steps to minimize the possibility of an explosion or incorrectly charging the battery You should turn the charger OFF before connecting or disconnecting cables to a battery Do not wiggle the cable clamps while the battery is recharging because a spark might occur and this could cause an explosion Good ventilation or a fan is recommended to disperse the gasses created by the recharging process gt Ifa battery becomes hot over 43 3 C 110 F or violent gassing or spewing of electrolyte occurs turn the charger off temporarily or reduce the charging rate gt When charging the battery in the car with an external MANUAL charger make sure that it will not damage the vehicle s electrical system or components with high voltages Even if this is a remote po
19. ding Test 7 1 Starter Test 1 With engine OFF place the vehicle transmission in NEUTRAL for Manual and PARK for Automatic then apply the parking brake 2 Connect the analyser to the battery terminals and the display will light up as shown Fig 50 below Select Menu AV Select Test AV 02 04 2014 10 38 New Test Alternator Test Other System Test Grounding Test 32 Stored Results Enter to proceed Setup Menu Fig 50 Fig 51 BESA 12PM Version PM1504 ss BESA 12PM User s Manual 3 Selecting Starter Test Fig 51 will proceed to the display below Fig 52 Vehicle Details VA Input lt gt Move Fig 52 Enter to proceed 4 Here it let you key in the particulars e g license plate number etc To key in the alphabets or numbers keep pressing a or x key to scroll from X Y Z 0 1 2 3 in a loop sequence and stop it when found Press D key to move to the next or a key to move backwards to continue the key in Note If you do not input any particulars and straight away press key to continue then the test results will not save in its memory 5 After completion of the input press key will proceed to the next display as shown in Fig 53 below Starter Test Battery TA Zeon Fig 53 Crank engine now until it starts Then press Enter 6 Switch the ignition key to ON and start cranking the engine until it starts Immediately after that press key and
20. disconnect the connections and test them individually e Battery that has just been charged by the charger contains surface charge and it should be discharged by turning ON the Head lights for 3 5 minutes before testing e Always attached the analyser clips on the lead side of the battery terminal posts during testing so that it has a good contact This will provide better and accurate results BESA 12PM Version PM1504 WI BESA 12PM User s Manual e Do not attach the analyser clips directly onto the steel bolt that tightened to the battery terminal posts this may give inaccurate readings or inconsistent results Note This also applies to all other battery testing methods e fthe battery terminal posts were oxidised or badly corroded and the connections were bad the analyser will prompt you to check the connections In this case clean the terminal posts and performs testing directly on the terminal posts it self e During testing on the battery whist it is still in the car make sure the engine is OFF e Do not store the analyser near high humidity or temperature area Exposing to extreme temperatures will cause damage to the unit 3 0 Working with Batteries 4MCAUTION Lead acid batteries contain a sulfuric acid electrolyte which is a highly corrosive poison and will produce gasses when recharged and explode if ignited It can hurt you badly When working with batteries make sure you have plenty of ventilation remo
21. e engine to 3 000 rpm Press Enter Hold on Fig 61 to this 3 000 rpm for 10 seconds and release the pedal 36 Follow the instructions make sure that all loads lights air condition etc are OFF Rev the engine up to 2 500 3 000 RPM by referring to the dashboard meter then press key and maintain the engine speed for about 10 seconds and release the pedal The maximum and minimum voltages values will be captured BESA 12PM Version PM1504 ES BESA 12P M User s Manual After that press key again and it show as below Fig 62 No Load Test At 3 000 rpm Av Volts Charging Volts range limit Max Min Average Charging Volts Captured Volts readings 14 2V 14 6V 13 8V lt 15 OV ON Press Enter for results With the captured readings analysis can done by Fig 62 to the limits as indicated that MAX voltage should not exceed is uv unax voltage at 3 000 RPM and MIN voltage should be more than 13 3V min voltage during idling speed 5 Press key will show the results of the test Fig 63 Results Good At 3 000 rpm No load Test Average Charging Volts Fig 63 Press 14 2V Enter to continue to Loading Test 6 If either minimum or maximum charging volts are not within the voltage range limits then it will display one of the screen as below Fig 64 amp 65 and it will prompt you to check the charging system for the fault
22. e menu check the battery specification value This value can be checked on the battery labels as some of the examples shown below iJ a Tai Te SMe H TOTROS If it is selected under JIS Japanese Industrial Standard then the display will prompt you as shown Fig 27 below Please refer to the charts provided for converting JIS to CCA ratings before Figure 27 a keying in the values 20 Press Enter to COMME TINE BESA 12PM Version PM1504 Wa BESA 12PM User s Manual Refer to the battery model example 80D26L or NX110 5L on the Cold Cranking Amps CCA Table list which is supplied separately See example Fig 28 below Battery Model JIS Battery Model JIS CMF CMF NEW OLD WET MF SMF OLD WET MF SMF S0D20R 3u 30 480 OA 500 500 om 5002 s0 30 480 eBo o 50D23R e BReoK 50 esere f 50023 e5B860K 500 95D3iR NXiZ0 7 620 660 850 50D24R NTe0 56 30 S07 N 50B24L NTe0 56L 30 _ S5e4iR N00 S0D2R 50020R 30 Sem N0 Figure 28 Press key and the display will show Fig 29 below Input Battery Rating Increase decrease A Single digit V lt q By hundredth gt Figure 29 100 CCA Press Enter to proceed 13 Referring to the Table list Fig 28 basing on 80D26L check the battery type WET MF Sealed MF or Closed MF CMF as each category has different CCA ratings For instance if
23. elow 75 and it will prompt you with the display as shown Fig 43 below Below 0 C gt Above 0 C Fig 43 Then press Enter 27 7 Here it let you to select the surrounding temperature that you are working with the battery If the surrounding temperature is for example 15 C then select Above 0 C by pressing z key and then press key Then the results will show on the LCD display R amp J Batteries Version PM1504 BESA 12PM User s Manual EB 1 Rating 120 CCA 2 3 Measured 95 CCA Volts 12 60 V 4 5 Int R 28 42 mOhm Life 69 6 Fig 44 Interpretations of the above Fig 44 results 1 Battery Good A very straight forward display of the final results basing on the evaluation of the tested condition Good indicates the battery in top condition OK Recharge indicates that the battery is in good condition but need to recharge to give its maximum performance Replace indicates that the battery needs to be replaced If not the battery will fail anytime without any warning 2 Rating 120 CCA The battery capacity rated output is normally stated on the label for car batteries For other batteries please refer the chart provided or check on information provided on the label 3 Measured 95 CCA It means that the battery tested has a capacity of 95 CCA power available CCA ratings has been used here therefore the tested result is in CCA and if other rating DIN SAE JIS IEC CA o
24. est results will not save in its memory 24 BESA 12PM Version PM1504 as BESA 12PM User s Manual 4 After completion of the input press key will proceed to the next display as shown in Fig 20 below Battery Type Regular WET Pb Pb Regular WET Pb Ca MF VRLA Ca Ca AGM Flat plate AGM Spiral wound GEL cell Fig 37 EFB Start Stop Here it will let you select the type of battery construction that you are testing Always refer to the table provide if you are not sure Once it has been selected press key to proceed 5 The next display Fig 38 below will ask the type of application that the battery being used Select Motorcycle if you are testing motorcycle battery and then press key Once entered it will proceed to display Fig 39 as shown below Application AV Select Rating VA Automotive AB Commercial vehicle DIN Motor Scooter JIS Marine Watercraft Lawn Mover Golf Cart Snowmobile Unknown Fig 38 Fig 39 2 Before selecting the ratings CCA SAE EN IEC DIN CA and JIS from the menu check the battery model This can be checked on the battery labels as some of the examples shown below 25 R amp J Batteries Version PM1504 BESA 12PM User s Manual SED With the battery model in hand refer to the Battery rating chart as seen in this example Fig 38 below provided in separate copies with the Tester when purchased to get values to be keyed in WES TACI
25. g P tn Welcome to the InstallShield Wizard for PL 2303 US6 to S erial The InstallShield Wizard will install PL 2303 USB to S eral on your computer To continue click Next lt Back Newt As instructed click Next gt tab the program will continue to install the driver on the computer Once it had finished it will prompt you as shown below Click Finish tab to complete the installation The InstallShield Wizard has successtully installed PL 2303 USB to Seral Click Finish to esit the wizard 49 aa ae Step 3 Next open this folder again J EEPE AEE es Look for the program icon see below wl icp ee TLE R amp J Batteries Version PM1504 BESA 12PM User s Manual ESO Then double click it The software will start to install and will prompt with the display below Then double click it The software will start to install and will prompt See example below Click OK tab to continue the installation and the software will start to install A few seconds later the display will show as below that the installation has been completed and click Finish tab to exit Installation Complete _50 Once the software has been installed the icon the desktop en will appear on BESA 12PM Version PM1504 Ws BESA 12PM User s Manual Step 4 Now plug the Analyzer into any one of the PC USB port Step 5 On the PC go to desktop display and look
26. hen try plugging the Analyzer to the PC s another USB port and repeating Step 4 to Step 6 again 10 2 Printing Results from PC Printer While on this page if you wish to print out the results make sure that your printer is connected to the computer Click on PRINT tab and a text box will appear Select the right printer and click Print tab to print Test Report COMP Print Select the printer which is connected eo E Microsoft XPS Document Writer Sp sna Samsung ML 2010 Series to your computer ae Auto Adobe PDF on ADL D Send To OneNote 2007 here R amp J Batteries lt Status Offline Printto file Preferences Location Comment Fou Pinte Page Range Number of copies h r 53 Version PM1504 BESA 12PM User s Manual Sy 10 3 Saving Results to PC lf you wish to save the results from this page then click on SAVE AS tab A message box will appear Type in the file name and click Save tab g Test Report COMPORT COM4 1 Battery Test y State of Charge 12 49 Volt Language English Capacity available 363 CCA Internal resistance 7 43 mOhm Life expectancy 60 Test Date 2013 07 10 Save As Select where you want to save in ave in Customer Car Plate Reference amy Network Places NO Menu For BESA amp BPA 11 Menu For New Testers Battery Model Type the file name here ile name 201307101003 Save as type
27. ill be tested with this analyser To perform the test just clamp the analyser clips onto the battery terminals and it will display the screen Fig 46 as shown if its voltage falls below the normal 12 0 volts Battery voltage is below 12 00 Volts Fig 46 Press Enter to Conti nuca Press key to continue and the display will show Fig 47 Select Rating VA CA 31 Fig 47 R amp J Batteries Version PM1504 BESA 12PM User s Manual ER Check the battery ratings and enter it as described in steps 13 to 15 page 20 21 and the results will show as an example below Fig 48 and Fig 49 Battery OK Recharge Battery To replace Rating 400 CCA Rating 400 CCA Measured 220 CCA Measured 120 CCA Volts Ig Sho Volts 10 56 V ite ke ie Alan Int R 22 50 mOhm Fig 48 State of Charge is State of Charge is Fig 49 low Charge battery low Internal and test again resistance is high Fig 48 Results shown OK Recharge it indicated that the battery has to be fully charged first before repeating the test For Fig 49 the Results shown To replace this meant that the battery need to be replaced as its internal plate resistance Int R is higher than 15 0 mOhm 15 Pressing the Ce key at any moment will exit and return back to the main menu screen Fig 35 7 0 Other System Test When this item is selected it will allow you to select one of the three Tests namely Starter Test Charging Test and Groun
28. ings reference table list provided basing on the JIS model number See page 29 amp 30 e DIN Deutsches Industrie Normen Standard Basing on DIN the rating requires that at O F 18 C the 12V battery is able to deliver the number of amperes while maintaining a voltage level of 9 0 Volts for 30 seconds and 8 0 Volts for 150 seconds during cranking e CA Cranking Amperes Rating This rating is the number of amperes that a new fully charged battery can delivery at 32 F 0 C for 30 seconds while maintaining a voltage level of 7 2 Volts for a 12V battery during cranking e Unknown If you are not sure which ratings CCA EN IEC JIS or DIN that the battery is based on then choose this setting It will show the battery s Voltage State of Charge CCA and the Internal Resistance m Ohm only This selection can also be used to test 12V Deep Cycle Batteries An example of the results display is shown below Fig 45 BESA 12PM Version PM1504 Ps BESA 12PM User s Manual Measured 220 CCA Volts O ON Int R 12 27 mOhm Fig 45 To determine the condition of the tested Deep Cycle Batteries refer the Volts reading State of Charge should not fall below 12 60V when fully charged for Lead Acid Batteries 12 85V for Gel Batteries and 12 80V for AGM Batteries and the Internal Resistance Int R of the tested battery should not be more 15 mOhm readings Batteries that had been left idle for long periods can st
29. ion PM1504 BESA 12PM User s Manual Ey 5 7 Erase Memory This Analyser is able to save up to 300 test results in its memory In event that you need to clear all the results in the memory to make for new ones after they had been backed up into the PC then select this item Erase Memory and press key to enter into it Once entered the display will show as in Fig 13 below Erase memory Erase memory Erase Memory Erase Memory Enter to proceed Enter to proceed adao ceive e eo alee Fig 13 Fig 14 To erase the memory now press key and it will proceed with the erasure as shown in Fig 14 above After completion it will return to the setup menu Fig 11 6 0 Battery Test Performing Battery Test while it is still on the car Automotive Only Vehicle that was running has to have its engine OFF first and then switch ON the headlights for 30 seconds to remove the surface charge After the headlights had switched OFF let the battery rest for at least 1 minute to recover before testing commences The car engine and all other accessory loads must be OFF during test in order to have accurate results When attaching the analyser clips make sure that the battery posts were not oxidized or badly corroded Clean them first before clamping to it Do not clamp onto the steel bolts directly which may give inaccurate and inconsistent results aaa BESA 12PM Version PM1504 SS BESA 12PM User s Manual Testing on
30. ish Capacity available 363 CCA Internal resistance 7 43 mOhm You can type in iia Co eee eon the particulars 2 Grounding Test here and then epee ae No results for viewing click Add to Test yor asses No results for viewing Report tab to be anne SPEU oOo 4 Alternator Charging Test Without electrical load at 3 000 rpm included in the Memory cleared No results for viewing test report which ono fe With electrical loads ON at 2 000 rpm Memory cleared No results for viewing will be stored pees mooo and printed out if you wish Add To Test Report Header Footer 4 f you need to view another test result press gt key to go back to the display as shown in Fig 95 5 Select the next test Result and press key and as usual the display will go to the particulars screen Fig 96 Now press key again will display the results 6 ON the PC click Get Data from Analyser tab and the results will be transferred to the PC ay ae BESA 12PM Version PM1504 SS BESA 12P M User s Manual lf there is no communication a message text box will appear see below Check Communication In this case unplug the Analyzer from the PC and repeat Step 4 to Step 6 If problem persist then select an alternate COMPORT individually from the dropdown list and click Get Data From Analyser tab to see whether the Last Test Result will appear as displayed in step 6 No 4 lf the above fails again t
31. it will be included in the test results when printed out It will also be saved as well in the memory which can be called up for later viewing and printout Note If you do not key in any particulars e g license plate number etc the results obtained will not be saved in the memory Stored Results The Analyser allows saving up to 300 tested Results in its memory Access into this function will permit you to view the tests done previously and also able to print out a hardcopy of it whenever needed Use v7 or A keys to scroll for the pages during viewing Examples of the results Results High Ohms Measured 406 CCA The grounding Rating 630 CCA resistance of the Volts E engine or car Int R 6 72 mOhm chassis LS high Lite 76 Clean the cable contacts or replace cable if necessary Fig 17 Fig 18 s16 BESA 12PM Version PM1504 WI BESA 12PM User s Manual 6 1 Begin Battery Test Automotive 1 After you have made your choice selecting New Test will proceed to the display below Fig 19 Vehicle Details VA Input lt gt Move Fig 19 i Enter to proceed 3 Here it lets you to key in the particulars e g license plate number etc that you need to be included into the test report when printed out after the test and it also serves as the name for the record to be saved in its memory for easy search 4 To key in the alphabets or numbers keep pressing vy or a key to scroll from
32. letion of the full test Outside vehicle Selecting this item will only test the Battery only whether the battery is inside the car or outside 8 After you had made your choice pressing key will proceed to do the battery testing and if it has detected any surface charge on the battery it will start to remove it and a message is shown Fig 23 below The Analyser is removing the battery surface charge now 18 Fig 23 Please wait for a moment BESA 12PM Version PM1504 WG BESA 12PM User s Manual 9 Ifthe surface charge is too great for the analyser to handle it will prompt you with the instructions as shown Fig 24 below and the beeper will sound continuously Battery surface charge is present Turn the ignition key Fig 24 to ON position Switch ON the headlights to remove surface charge 10 Wait until the surface charge removal had completed the analyser will advise as follows Fig 25 and then press key Battery surface charge has been removed Fig 25 Turn ignition key to OFF position Switch OFF the headlights and then press Enter 11 If there is no surface charge present then it will straight away enter into Select Rating menu screen as shown in Fig 26 Select Rating VA CA s19 Fig 26 Unknown R amp J Batteries Version PM1504 BESA 12PM User s Manual P 12 Before selecting the ratings CCA SAE EN IEC DIN CA and JIS from th
33. nd release the pedal The maximum and minimum voltages values will be captured Fig 67 At 2 000 rpm Av Volts ks iil mx liebe DUS BV LS sy Min 2 ON SNA Sy Average Charging volts Captured Volts readings Normal Charging paai 38 range limit Press Enter for re ult Fig 67 BESA 12PM Version PM1504 SS BESA 12P M User s Manual With the captured readings analysis can done by referring to the limits as indicated that MAX voltage should exceed 13 5V max voltage at 2 000 RPM and MIN voltage should be more than 12 5V min voltage during idling speed After that press key again and the results will be shown as below Fig 68 Results Good At 2 000 rpm Loading Test Average Charging MOIS Ls ol Fig 68 8 If either minimum or maximum charging volts are not within the voltage range limits then it will display one of the screen as below Fig 69 amp 70 and it will prompt you to check the alternator system for the fault Results Low charge Results Low charge At 2 000 rpm At 2 000 rpm Loading Test Loading Test WED Das ON a IL By Mins ZA 12 ae Check for loose belt Check for loose belt and the alternator and the alternator Fig 69 Fig 70 11 Just press key if you need to printout the results m 12 Continue from the previous test either Fig 68 69 or 70 the display will automatically switch to Diode Ripple Test Fig 17 as below R
34. ng terms used as shown on the LCD display R amp J Batteries Version PM1504 BESA 12PM User s Manual P e CCA Cold Cranking Amps most commonly used Standard CCA is a rating used in the battery industry to rate a battery s ability to start an engine in cold temperatures This rating is the number of amperes that a new fully charged battery can delivery at O F 18 C for 30 seconds while maintaining a voltage level of 7 2 Volts for a 12V battery during cranking e SAE The Society of Automotive Engineers Standard SAE has established Cold Cranking Amperes CCA rating for batteries as their standard Therefore this rating is the same as CCA rating as mentioned above e IEC International Electro technical Commission Standard IEC rating require that at O F 18 C the number of amperes that the 12V battery can deliver while maintaining a voltage level of 7 5V for 10 seconds and 7 2V for 30 seconds during cranking e EN European Norm Standard EN 1 rating require that at O F 18 C the number of amperes that the 12V battery can deliver while maintaining a voltage level of 7 5V for 10 seconds stop for 10 seconds and continue with 60 load with maintaining voltage level of 7 2V for 70 seconds during cranking Total time 90 seconds e JIS Japanese Industrial Standard JIS amperes rating is based on Ampere Hours and is calculated using 20 hours rating In this manual it is using CCA rat
35. r EN were selected it will base on the respective rating to calculate and show the results in that selected rating 4 Volts 12 60V The volts here indicated the State of Charge SOC of the tested battery which is 12 60V during open circuit condition 75 SOC for AGM batteries by referring to the table below AGM 100 12 60V or higher 12 85V or higher 12 80V or higher 28 12 58 V 12 77 V 12 72 V 12 44 V 12 69 V 12 64 V 12 40 V 12 65 V 12 60 V 12 20 V 12 35 V 12 30 V BESA 12PM Version PM1504 ass BESA 12PM User s Manual Please take Note This output value 95 CCA is related to the actual power available in the battery in relation to that battery s rating 120 CCA On average a new battery s CCA as measured by this tester will read 10 15 higher than its stated rating As the battery ages the CCA number measured by this tester will decrease so it reads near its rating While this value is not the same as a CCA test it is the best available measurement for showing a battery s current condition in relation to its rating From the above example a 120 CCA rated battery measuring 95 CCA available power does not mean that the battery would pass a CCA test at 95 CCA The available power reading shows that the battery is not able to perform up to its rated ability 120 CCA In comparison to another battery when fully charged the 120 CCA battery measuring 95 CCA is no stronger than a 90 CCA battery showing 90
36. rinter Page 52 To exit the program pressing the back to the main menu screen Fig 89 key at any moment will exit and return 10 0 PC Link A BESA 12PM is also designed to link with PC for data storage and printout through PC printer To do so the PC has to install the driver and the software provided in order to operate 10 1 Installing Driver Important Note Before you start to install the driver please do not plug BESA 12PM into the computer s USB port or else the installation will fail and the computer cannot detect the proper driver for BESA 12PM when connected If you have made the above error and wish to install the driver the second time you need to uninstall the previously installed driver first before starting to reinstall again This time make sure that BESA 12PM is not plugged in m Step 1 You can install the driver from the CD provided or download it from our website http www aetool com productshow asp id 1055 amp sortsid 0 amp catego ryid 219 BESA 12PM Version PM1504 ss BESA 12PM User s Manual First click to open the folder m BESA Software and Driver You will find the following files l EEEE xP _Vista_7 Driver Installer exe o o tier ipee o i di p App Macrovision Corporation Step 2 Double click on the icon 03 The installation will start automatically Typical example below is for Windows 7 operating system aaa PL 2303 Driver Installer P em nyver instaner rogram
37. s of these circuits will subject to oxidation and corrosion in a matter of time rendering them to have high resistance in it One typical example is the connection at the battery terminals where oxidation and corrosion takes place very often If these contacts were no good then it will pose a lot of electrical problems to the vehicle To check the grounding condition this Analyser will measure the resistance from the engine body contact to the battery terminal then it will display the results and the recommendations Start Testing 1 With engine OFF place the vehicle transmission in NEUTRAL for Manual and PARK for Automatic and apply the parking brake 2 Attach the Analyser clips onto the battery terminal posts and it will power up and lights up the LCD display screen as shown Fig 75 Press key and the display will show as Fig 76 below Select Menu AV Select Test AV 02 04 2014 10 38 Starter lesi New Test Alternator Test Other System Test Grounding Test Stored Results Enter to proceed 41 Setup Menu Fig 75 Fig 76 R amp J Batteries Version PM1504 BESA 12PM User s Manual ER 3 Select Grounding Test and it will proceed to the display below Fig 77 Vehicle Details VA Input lt gt Move Enter to proceed Fig 7 4 Here it let you key in the particulars e g license plate number etc To key in the alohabets or numbers keep pressing 7 or a key to scroll from X Y Z 0 1 2
38. ser display will light up as shown Fig 81 Grounding Test Fig 81 Press Enter to continue the test vref 10 Now you need to press key to proceed and the display will show as follows Fig 82 11 R amp J Batteries Version PM1504 BESA 12PM User s Manual Analysing Please wait Fig 82 BERRREE 12 If the measured resistance reading is within limits then it will display as follows Fig 83 Results OK The grounding resistance of the Fig 83 engine or car chassis is within limit 13 If the measured resistance reading has gone beyond the limits then it will display the screen as follows Fig 84 Results High Ohms The grounding resistance of the Fig 84 engine or car chassis is high Clean the cable contacts or replace cable if necessary 44 BESA 12PM Version PM1504 ss BESA 12PM User s Manual Fig 86 Note The above indicates that the ground contact from the engine body to the battery is bad Check for rusted or corroded point of contacts If found dismantle it for cleaning or replace before fixing back Repeat the test again after fixing Another thing is that if you suspect that the result is in question you may conduct the test with the Black clip clamp at different location 14 If you did not follow the right procedures during the testing it will display the results as follows Fig 85 below Results Not detected Grounding test Failed
39. ssibility it is best to disconnect the vehicle s battery cables from the battery BEFORE connecting the charger BESA 12PM Version PM1504 E SESA 12P M 4 0 The Battery Electrical System Analyser User s Manual 4 1 BESA 12PM LCD Display Screen USB port for connection to PC Fig 1 R amp J Batteries Printer Fault indicator LED Printer power LED Black Clamp to battery negative post Red Clamp to battery positive post Version PM1504 BESA 12PM User s Manual EO 4 2 Keypad Functions Battery Electrical System Analyser 12V lt A gt Fig 2 MERA 4 3 Functions of Individual key 1 A gt Vv sg a 6 amp BESA 12PM Use this key to scroll up to the next item OR when it is in the Battery Rating mode pressing this key once will increase the value by 5 Use this key to shift the selection tab to the right OR when tt is in the Battery Rating mode pressing this key once will increase the value by 100 Use this key to scroll down to the next item OR when it is in the Battery Rating mode pressing this key once will decrease the value by 5 Use this key to shift the selection tab to the left item OR when it is in the Battery Rating mode pressing this key once will decrease the value by 100 10 Press this ENTER key to select the function or proceed to the next step To EXIT the function press this key once and return to the previo
40. stand alone batteries Motorcycle amp Others Clean the battery posts with a wire brush prior testing For side post batteries install stud adaptors Do not use steel bolts for better results 1 Attach the Analyser clips onto the battery terminal posts Red to and Black to the unit will power up and lights up the LCD display screen as shown Fig 15 Fig 15 2 It will run through a self test and when completed it displays the Main Menu as shown Fig 16 Select Menu AV 02 04 2014 10 38 Fig 16 Other System Test Stored Results Setup Menu Here it will let you select your choice from the Menu New Test This function will allow you to key in the particulars e g license plate 15 numbers names etc that you need before commencing the test The particulars will be included in the test results when printed out from its printer It also allows the test Results to be saved in its memory which can be called up for later viewing and printout Note If you do not key in any particulars e g license plate number etc the results obtained will not be saved in the memory R amp J Batteries Version PM1504 BESA 12PM User s Manual SE Other System Test This selection consists of three individual tests namely Starter Test Charging Test and Grounding Test Selecting anyone of these Tests will require to key in the particulars e g licenses plate numbers names etc before commencing the test and
41. the battery is a Sealed MF CMF then it is rated at 680 CCA Note WET Wet Cell Type MF Maintenance Free Type SMF Closed or Sealed Maintenance Free 21 R amp J Batteries Version PM1504 BESA 12PM User s Manual EDR 14 To enter the value 630 press ID key will increase the original value of 100 Fig 29 by step of 100 units to 600 Likewise use A key to increase the last two digits 00 to 30 by step of 5 units for each pressing See Fig 30 Increase decrease A Single digit V Fig 30 lt q By hundredths gt 630 CCA Press Enter to proceed Once the CCA rating of the battery is confirmed press key will start the testing process Refer to the display below Fig 31 Analysing Fig 31 Please vail 15 For less than 8 seconds the results of the testing will be displayed on the LCD screen Fig 32 Racinz 630 CCA Weaswirad 520 CCK cold Volis Deas Int R 5 09 mOhm Lite 76 Fig 32 BESA 12PM Version PM1504 We BESA 12PM User s Manual 16 This Analyser will also takes the temperature of the battery into consideration when it has detected that the battery condition is marginal below 75 and it will prompt you with the display as shown Fig 33 below Below 0 C gt Above 0 C Fig 33 Then press Enter 17 Here it let you to select the surrounding temperature that you are working with the battery If the surrounding temperature is for example 15
42. the results will show as 33 follows Figure 54 R amp J Batteries Version PM1504 BESA 12PM User s Manual Ray Result OK Battery 12 45V Min Volts 10 56V Volt Drop Normal Fig 54 Exit to Menu 7 Ifthe voltage drop is too great during the cranking the tested results will display as follows Fig 55 and will prompt you to check the starter system Result High Drop Battery LA eo Min Volts 8 56V Volt Drop High Fig 55 Check starter relay battery terminals or battery has aged Exit to Menu 8 During cranking when it detects that there is no drop in voltage it will display the following screen Fig 56 Result Not detected Battery 12 45V Sse ale WAS ie LE No change in volt Fig 56 drop Check clamping at battery side and test again 34 Exit to Menu 6 Pressing the Go key at any moment will exit and return back to the main menu screen Fig 50 BESA 12PM Version PM1504 SS BESA 12PM User s Manual 7 2 Alternator Test This test is to check the MAX and MIN charging voltages output of the alternator at 3000 RPM without load and 2000 RPM with all loads ON With this test you can determine the alternator s condition when in reference with the vehicle s Service Manual Starts with No load testing at 3 000 RPM 1 With engine OFF place the vehicle transmission in NEUTRAL for Manual and PARK for Automatic and apply the parking brake 2 Attach the
43. ults are highly accurate Extremely safe as it does not create any sparks during clamp on and it takes less than 8 seconds to obtain the full analysed results of the battery being tested 2 Starter Test Checks the cranking effectiveness of the battery to predict when the battery will fail to crank a vehicle basing on voltage profiles with results and recommendations display 3 Charging Test his test checks the alternator charging condition during electrical loading at 2 000 RPM and without load at 3 000 RPM with results and recommendations displayed after each test 4 Grounding Test Analyses the condition of the electrical return circuit contacts resistance which was connected to the engine or chassis body from the battery terminal with results and recommendations displayed after testing R amp J Batteries Version PM1504 BESA 12PM 1 2 Specifications Operating Voltage Safety Analysing Capacity Amps Automotive Commercial vehicle Marine Watercraft Motorcycle Motor Scooter Lawn Mover Golf cart Snowmobile DC Volts Accuracy Battery analysing time Language Memory PC connection Printer head Paper width Paper roll diameter Printing speed Working temperature Working Humidity BESA 12PM User s Manual ey 9V 15V DC max Built in reverse polarity protection CCA 100A 1700A EN 100A 1000A IEC 100A 1700A DIN 100A 1000A JIS 100A 1700
44. us screen Version PM1504 Wa BESA 12PM User s Manual 7 Press this key to print test results on the built in Printer after a test or in View Last Test mode 5 0 Initial Setup 5 1 Paper installation Open the printer cover by pushing it upwards from the middle Place the thermo paper roll into the slot with the paper edge facing up Fig 3a Make sure the paper is about 20mm out when the printer cover is closed Fig 3b Fig 3a Fig 3b 5 2 Setup Menu To access into this function go to the main screen Fig 4 as shown below select Setup Menu Fig 5 and press key Select Menu AV Select Menu AV 02 04 2014 10 38 02 04 2014 10 38 New Test Other System Test Other System Test Stored Results Stored Results 11 Setup Menu Setup Menu Fig 4 Fig 5 R amp J Batteries Version PM1504 BESA 12PM User s Manual ED 5 3 LCD Brightness While you are in the Setup Menu display select LCD Brightness from the menu Fig 6 Once entered the display will show as in Fig 7 To increase the contrast press D key and the bar graph will move forward Likewise to decrease press key while in this screen Setup Menu Language LCD Brightness Printer Set date amp time PC Link Erase Memory Fig 6 Fig 7 Once the LCD brightness has been confirmed press key to save and it will return back to the Setup Menu screen above 5 4 Printer Selecting this Printer mode
45. ve 12 months which begins from the date the product is purchased by the end user and is subjected to the following terms and conditions 1 Within the warranty period the manufacturer will repair or replace at their options any defective parts and return to the owner in good working condition Any repaired or replaced parts will be warranted for the balance of the Original warranty or three months 3 months from the date of repair whichever is longer This warranty only extends to the first owner and not assignable or transferable to any subsequent owner Cost of delivery charges incurred for the repair of the product to and from the manufacturer will be borne by the owner This limited warranty covers only those defects that occur as a result of normal use and do not cover those that resulted from e Unauthorized modifications and repair e Improper operation or misuse e Accident or neglect such as dropping the unit onto hard surfaces e Contact with water rain or extreme humidity e Contact with extreme heat e Broken cables bent contact pins or subject to extreme stress or wear e Physical damage to the product surface including scratches cracks or other damage to the display screen or other externally exposed parts 55 R amp J Batteries Version PM1504 BESA 12PM User s Manual SSE 11 2 Limitations of Warranty Other than the foregoing limited warranty the manufacturer does not make any other w
46. ve your hand jewelry watch and wear protective eyewear safety glasses clothing and exercise caution Do not allow battery electrolyte to mix with salt water Even small quantities of this combination will produce chlorine gas that can KILL people Whenever possible please follow the manufacturer s instructions for testing jumping installing charging and equalising batteries DANGER POISON FLUSH EYES Wie SHIELD NY i SULFURIC bc 10 EXPLOSIVE o gt Me SPAR GASESC time Io aes i REARS JA FSUAIMESS GAINJURY T Smoking T SEVERE BURKS KEEP OUT OF THE REACH OF CHILDREN DO MOT TIP KEEP TENT CAPS TIGHT AHC LEVEL gt Never disconnect a battery cable from a vehicle with the engine running because the battery acts like a filter for the electrical system Unfiltered pulsating DC electricity can damage expensive electronic components e g emissions computer radio charging system etc Turn off all electrical switches and components turn off the ignition before disconnecting the battery R amp J Batteries Version PM1504 BESA 12PM User s Manual EB gt For non sealed batteries check the electrolyte level Make sure it is covering the plates and it is not frozen before starting to recharge especially during winters gt Do not add distilled water if the electrolyte is covering the top of the plates because during the recharging process it will get warm and expand After re
47. y pressing A or v key If you do not find the name then press jD or K key to continue to the next page in event that it is full 6 Once selected the display will show the date with time and particulars that you have selected and keyed in during the test done Fig 91 I OT OMAS Fig 91 ADC8899L Automotive Regular Wet Pb Pb Outside Vehicle Press key will proceed to show the test results some examples of the Results are shown below are Figs 92 amp 93 Result High Drop Rating 500 CCA Min Volts 8 56V Measured 129 CCA Volt Drop High Fig 92 Volts 12 85 V Fig 93 47 Int R 20 91 mOhm Check starter relay Life O battery terminals or battery has aged Pree aie xcs Eo main menu R amp J Batteries Version PM1504 BESA 12PM User s Manual ERB 9 0 Printing the previous Test Results from Memory To print out the previous results from its memory select Stored Results from the menu Access to the recorded names example Fig 90 select and press key will display the results To print just press key on the Analyser the printer will start printing Important The Analyser has to be connected to a 12V battery in order to work with the mobile printer This is because the printer needs higher Amps to operate which the PC USB output is unable to provide Note To printout on PC printer it has to be connected to the PC with BESA 12PM software installed See Print Results from PC P