Home

GE-DS-82 and GE-DS-82-PoE Managed Switch

image

Contents

1. 3 of 11 Figure 2 The COM1 properties window COM1 Properties Port Settings Bits per second 1 Ww hl Ww Bae Restore Defaults Logon to the Console Once the terminal has connected to the device Supply power to the GE DS 82 and the GE DS 82 PoE Managed Switch the terminal will display that it is running testing procedures The following message asks for the login username and password The factory default password for the login screen is e Username admin e Password admin 4of11 P N 1069669 REV 1 01 ISS O3MAR10 Figure 3 GE DS 82 Login screen COM1_5 7600 HyperTerminal File Edit View Call Transfer Help Dae 553 028 Username admin Password Switch _ Connected 00 02 14 ANSIW 57600 8 N 1 Note For security reasons please change and memorize the new password after this first setup Passwords must be entered in lowercase letters in the console interface P N 1069669 REV 1 01 ISS O3MAR10 5 of 11 Telnet Setup 1 Connect an RJ 45 cable from the PC to a Switch port on the Managed Switch Figure 4 RJ 45 connection diagram Managed Switch PC Workstation with IE Brower IP Adress RJ 45 UTP Cable 192 168 0 1 00 IP Adress 192 168 0 x 2 Launch the Hyper Terminal program A terminal program is required to make the software connection to the Managed Switch Windows Hyper Terminal program is a good choice Hyper Terminal can be accessed from the
2. GE Security GE DS 82 and GE DS 82 PoE Managed Switch Installation Sheet Package Contents Thank you for purchasing the GE Security 8 Port Fast Ethernet 2 Port Gigabit TP SFP Combo Managed PoE Switch The following Managed Switch model numbers are covered in this sheet e GE DS 82 e GE DS 82 PoE Open the box of the Managed Switch and carefully unpack it The box should contain the following items e The Managed Switch x1 e User manual CD x1 e This Installation Sheet x1 e RS232 cable x1 e Rubber feet x 4 e Two rack mounting brackets with attachment screws x1 e Power Cord x1 If any item is found missing or damaged please contact your local reseller for replacement 2010 GE Security Inc 1of11 P N 1069669 REV 1 01 e ISS O3MAR10 System Requirements Your switch is designed to operate with a variety of platforms operating systems and network cards Actual performance will depend on a combination of these components Differences in performance can occur depending on the versions and types of platforms operating system and network cards used The minimum system requirements are e Clients running Windows 98 ME NT4 0 2000 xP Vista MAC OS9 or later Linux UNIX or other platform compatible with TCP IP protocols e Workstation installed with an Ethernet NIC Network interface Card e Serial Port connection Terminal e Above PC with COM Port DB 9 e Ethernet Port connection e Network cables Use
3. Start menu Click START then Programs Accessories and then Hyper Terminal 3 The following screen will appear Input a new connection name You should use something like the model name of your switch Figure 5 The New Connection dialog window Connection Description aes a New Connection Enter a name and choose an icon for the connection Mame GE D5242 F0 F leon 6 of 11 P N 1069669 e REV 1 01 ISS O3MAR10 4 Change the Connect using drop down menu to TCP IP Winsock then input the Host address The Managed Switches default IP address is 192 168 0 100 and the default telnet port number is 23 then press the OK button Figure 6 The Connect to dialog window zjx GE DS242 POE Enter details for the host that you wart to call Host address f 92 168 0 100 Port number z Connect using TCRAP Winsock Cancel Log on to the Console Make sure the device finished booting Once telnet has connected to the device Hyper terminal will display the login request The following message asks for the login username and password The factory default password username and password is User name admin Password admin P N 1069669 REV 1 01 ISS O3MAR10 7 of 11 Figure 7 The Login request window Username admin Password Switch _ Connected 00 50 08 ANSIW 57600 8 N 1 Now you can configure the Switch by Telnet Web Browser Setup Start Web Management
4. The following shows how to start up the Web Management of the GE DS 82 Managed Switch Please note that the Managed Switch is configured through an Ethernet connection make sure the manager PC must be set on the same IP subnet address For example the default IP address of the GE DS 82 Managed Switch is 192 168 0 100 then the manager PC should be set at 192 168 0 x where x is a number between 1 and 254 except 100 and the default subnet mask is 255 255 255 0 8 of 11 P N 1069669 e REV 1 01 ISS O3MAR10 Figure 8 IP management diagram Managed Switch PC Workstation with IE Brower IP Adress RJ 45 UTP Cable 192 168 0 100 IP Adress 192 168 0 x Login to the managed Switch 1 Enter the IP address http 192 168 0 100 the factory default IP address or one you have previously changed in the console in the Web Browsers Address Field 2 The following dialog box appears please enter the default password admin or the password you have changed via console The login screen in Figure 9 appears e Default IP Address 192 168 0 100 e Default Username admin e Default Password admin Figure 9 Login screen Connect to 192 168 0 100 The server 197 168 0 100 at GE Security Web domain requires a Username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name f admin v C Remembe
5. r my password P N 1069669 REV 1 01 ISS O3MAR10 9 of 11 3 After entering the username and password the main screen appears as shown in Figure 10 Figure 10 Main Screen of the GE DS 82 GE DS 82 PoE eH SBI MENU Home System Welcome to GE Security GE DS 82 PoE 8 Port 10 100Mbps 2G TP SFP Combo Managed PoE Switch Port Configuration Layer 2 Features Security Qos Power over Ethernet Copyright 2009 GE Security Corporation All rights reserved 4 You can use the Web Management interface to continue the Switch management please refer to the user manual for more information NOTE For security reasons please change and memorize the new password after this first setup Resetting the IP Address To reset the IP address to the default IP Address 192 168 0 100 or reset the login password to default value Press the hardware reset button on the front panel for about 10 seconds After the device has rebooted you can login to the WEB Management interface within the same subnet of 192 168 0 xx 10 of 11 P N 1069669 e REV 1 01 ISS O3MAR10 Figure 11 Reset button 8 Port 10 100Mbps 2 Gigabit rer y e100 Managed Switch O 8 O O 7 O O GE DS 82 seal Contact information Thank you for purchase GE Security products You can browse our online FAQ resource at the GE Security website first to check if it could solve you issue If you need more support information please contact GE Securi
6. standard network UTP cables with RJ45 connectors e Above PC installed with WEB Browser and JAVA runtime environment Plug in Note We recommend using Windows XP or Windows 7 with Internet Explorer 6 0 or above for access to the switch management setup Zoni P N 1069669 REV 1 01 ISS O3MAR10 Terminal Setup Three are ways to access and setup your switch They are e RS 232 console e Telnet e Web Browser RS 232 console To configure the system connect a serial cable to a COM port on a PC or notebook computer and to the serial console port of the GE DS 82 Managed Switch The console port of the Managed Switch is DCE already so that you can connect the console port directly through PC without the need of Null Modem Figure 1 Terminal setup diagram PC Workstation Managed Switch with Terminal emulation software ox WY a RS 232 Serial Port 57600 8 n 1 Serial Port A terminal program is required to make the software connection to the GE DS 82 and the GE DS 82 PoE Managed Switch Window s Hyper Terminal program is a good choice The Hyper Terminal program can be accessed from the Start menu 1 Click START then Programs Accessories and then Hyper Terminal 2 When the COM1 Properties window appears configure the COM port with the following parameters and then click the OK button e Baud 57600 e Parity None e Databits 8 e Stopbits 1 e Flow Control None P N 1069669 REV 1 01 ISS O3MAR10
7. ty support team 888 GE Security 888 437 3287 Toll free in the US Puerto Rico and Canada 503 885 5700 outside of the toll free area For contact information see our Web site www gesecurity com For contact information see our Web site www gesecurity eu Copyright GE Security Technology Corp 2009 Contents subject to revision without prior notice GE Security is a registered trademark of GE Security Technology Corp All other trademarks belong to their respective owners P N 1069669 REV 1 01 ISS O3MAR10 11 0f 11