E1HBOX IP1982EN rev. 2012-03-22

image

Contents

1. TM ENTREMATIC HomeLink IP1982EN E1HBOX Installation manual for control panel for BOX3EH automation Motor 1 ANT JR4 Motor 2 du JD 08 BIXMR2 ue Black k 2 6 4 Sesion COM IN jj PRG BAT e BATK4 L 11 ON JR3 OFFLL2 5 45 E az 24 V a eo 7 7 Tanto gage T POWER VA VC TC R1 ALARM Step by step 140 1210 1591 10168 F1 C9 hd _ HERE 5 28 95 lt 88 o c T o 68 a oj TE i w x 9 Power suppl 3 2 ppy ox g gt c gt 2 o Sg e 9 o S 2 3 9 8 amp 2 O a 6 E S DITEC S p A Ta Via Mons Banfi 3 21042 Caronno Pertusella VA ITALY N Tel 39 02 963911 Fax 39 02 9650314 ICIM www ditec it ditec ditecva com ISO 9001 Cert n 0957 INDEX Subject Page 1 General safety precautions EC declaration of conformity Technical data 3 1 Applications Connection o
2. keep pressed for 3 s the PRG button on the radio receiver or on the control panel the SIG LED begins to flash to erase all the transmitters from the memory of the radio receiver keep pressed for 3 s again the PRG button to erase a single transmitter press one of the previously stored CH keys of the transmitter to be erased the cancellation is confirmed by the quick flashing of the SIG LED For further information see the user manual for GOL series transmitters If the control panel is replaced the storage module being used can be inserted in the new control panel WARNING the storage module must be inserted and removed with the power supply disconnected 9 IP1982EN 2012 03 22 9 START UP A 1 Make a jumper for the N C safety contacts If installed adjust the opening and closing stop limit switches NOTE limit switches must be kept pressed until the operation has been completed Set TC MAX Use DIP2 to set the installation position Switch on and check that the automation is operating correctly with subsequent opening and closing commands If installed check that the limit switches are activated Connect the safety devices removing the relative jumpers and check they work correctly If required adjust the automatic closing time with the TC trimmer WARNING the automatic closing time after a safety device has triggered depends on the DIP3 setting Set the desired opening and closing speed using the V
3. 1 9 N O HOLD TO RUN The opening of the 1 9 contact enables the hold to run func FUNCTION tion hold to run opening 1 5 with DIP1 ON hold to run closing 1 6 with 6 4 OFF NOTE any safety device automatic closing and plug in card inserted in AUX is disabled 0 11 N C CLOSING PROXIMITY With DIP2 OFF after the contact has opened the closing LIMIT SWITCH movement stops on the mechanical stop With DIP2 ON the opening of the contact stops the opening operation 0 12 N C OPENING With DIP2 OFF the opening of the contact stops the opening LIMIT SWITCH operation With DIP2 ON after the contact has opened the closing movement stops on the mechanical stop N O TRANSMITTERS WARNING the BIXMR2 storage module must be inserted STORAGE AND Transmitter storage CANCELLATION press the PRG key the SIG LED comes on PRG transmit the transmitter to be stored the SIG LED flashes wait 10 s to complete storage the SIG LED goes out Transmitter cancellation press the PRG key for 3 sec the SIG LED flashes press the PRG key for another 3 sec the SIG LED flashes quickly 5 IP1982EN 2012 03 22 6 OUTPUTS AND ACCESSORIES Output Value Accessories Description 01 24 V 0 3 A Accessories power supply Power supply output for external ac cessories including automation sta
4. 3 seconds preflashing Disabled during opening Enabled only with automatic closing with TC gt 3 s Enabled for both opening and closing Description OFF ON JR3 Automation type 2 motors automation 1 motor automation JR4 Incorporated radio receiver Disabled Enabled SO Reversal safety switch function With the automation With the automation blocked if the contact 1 8 blocked if the contact 1 8 is open it is possible to is open any operation is activate the opening opera impossible tion 6 4 Command 1 6 operation Closing Stop IP1982EN 2012 03 22 Trimmer Description min max Opening speed adjustment Adjusts the opening speed Closing speed adjustment Adjusts the closing speed TC Setting automatic closing time From 0 to 120 s L With DIP3 OFF once a safety switch has been activated the counter starts as soon 2 as the safety switch is released for example after passing through the photocells Os Disabled lasts for a period of time set with trimmer TC 50 With DIP3 ON the counter starts when automation is opened and lasts for the entire duration set with trimmer TC 100 NOTE after the activation of the stop command once contact 1 9 has closed again automatic closing is only enabled after a total partial or step by step opening com mand R1 Obstacle thru
5. nels and separated from the connections to the control and safety devices IP1982EN 2012 03 22 4 5 COMMANDS Command Function Description 1 5 N O STEP BY STEP With DIP1 OFF and TC lt MAX the closing of the contact acti WITH AUTOMATIC vates opening or closing operations in the following sequence CLOSING open stop close open NOTE the stop is not permanent but lasts for a duration set by TC STEP BY STEP With DIP1 OFF and TC MAX the closing of the contact acti WITHOUTAUTOMATIC vates opening or closing operations in the following sequence CLOSING open stop close open OPENING WITH With DIP1 ON and TC lt MAX the closing of the contact acti AUTOMATIC vates the opening operation CLOSING OPENING WITHOUT With DIP1 ON and TC MAX the closing of the contact acti AUTOMATIC vates the opening operation CLOSING NOTE once the automation stops the closing of the contact performs the opposite operation to the one performed before stop 1 t 6 SAFETY STOP With 6 4 ON all operations are stopped and or blocked when the safety contact is opened 1 6 NO CLOSING With 6 4 OFF the closing of the contact activates the clos ing operation 1 8 N C REVERSE The opening of the safety contact triggers a reversal of motion SAFETY CONTACT re opening during closing 1 9 N C STOP The opening of the safety contact stops the current operation
6. and remove any bridges on the control panel terminal board The automation opens closes briefly and then stops Encoder disconnected false encoder contacts encoder fault POWER ALARM led flashing Check that the encoder is connected correctly clean the contacts by con necting and disconnecting the encoder plug on the contacts replace encoder Motor leads crossed POWER ALARM led flashing Check the motor leads There is friction Manually check that the automation moves freely check the R1 adjustment The remote control has limited range and does not work with the automation moving The radio transmission is impeded by metal structures and reinforced con crete walls Install the antenna outside Substitute the transmitter batteries 11 IP1982EN 2012 03 22 TM NTRC MATIC DITEC S p A Via Mons Banfi 3 21042 Caronno P lla VA Italy Tel 39 02 963911 Fax 39 02 9650314 www ditec it ditec ditecva com DITEC BELGIUM LOKEREN Tel 32 9 3560051 Fax 32 9 3560052 www ditecbelgium be DITEC DEUTSCHLAND OBERURSEL Tel 49 6171 914150 Fax 49 6171 9141555 www ditec germany de DITEC ESPANA ARENYS DE MAR Tel 34 937958399 Fax 34 937959026 www ditecespana com DITEC FRANCE MASSY Tel 33 1 64532860 Fax 33 1 64532861 www ditecfrance com DITEC GOLD PORTA ERMESINDE PORTUGAL Tel 351 229773520 Fax 351 22 9773528 38 www goldporta com DITEC SWITZERLAND BALERNA Tel
7. with receiver 433 92 MHz is in conformity with the provisions of the following EC directives R amp TTE Directive 1999 5 EC EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC Caronno Pertusella 01 09 2010 ilvano Angaroni ddaging 3 TECHNICAL DATA E1HBOX Power supply 230 V 50 60 Hz F1 fuse F1 6A 1 motor output 24 V 9 2 motors output 24 V 2 5 5 Accessories power supply 24 V 0 3A Temperature min 20 C max 55 C Degree of protection IP24D Memorizable 200 radio codes Radio frequency 433 92 MHz E 0 m re stem me tm 3 1 Applications ZT 4 CONNECTION OF POWER SUPPLY Before connecting the power supply make sure the plate data correspond to that of the mains power supply An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout Use a HOSRN F 3 1 5 or HOSRR F 3G1 5 type electric cable and connect to the terminals L brown N blue yellow green in the automation Secure the cable using a special cable clamp Make sure there are no sharp edges that may damage the power supply cable Connection to the mains power supply in the section outside the automation is made with independent chan
8. 41 848 558855 Fax 41 91 6466127 wwwaditecswiss ch DITEC ENTREMATIC NORDIC LANDSKRONA SWEDEN Tel 46 418 514 50 Fax 46 418 511 63 www ditecentrematicnordic com DITEC TURCHIA ISTANBUL Tel 90 21 28757850 Fax 90 21 28757798 wwwaditec com tr DITEC AMERICA ORLANDO FLORIDA USA Tel 1 407 8880699 Fax 1 407 8882237 www ditecamerica com DITEC CHINA SHANGHAI Tel 86 21 62363861 2 Fax 86 21 62363863 www ditec cn
9. A and VC trimmers Set the obstacle thrust with the R1 trimmer WARNING after adjusting check that the working forces exerted by the door wings are compliant with EN12453 EN12445 regulations Connect any other accessories and check they operate correctly IP1982EN 2012 03 22 10 10 TROUBLESHOOTING Problem Possible causes Remedy The automation does not open or close No power POWER ALARM led off Check that the control panel is pow ered correctly Short circuited accessories POWER ALARM led off Disconnect all accessories from termi nals 0 1 voltage must be 24 V and reconnect one at a time Blown line fuse POWER ALARM led off Replace F1 fuse Safety contacts are open SA led on Check that the safety contacts are closed correctly N C The remote control does not work Check the correct memorization of the transmitters on the incorporated radio If there is a fault with the radio receiver that is incorporated in the control panel the radio control code can be read by removing the storage module Photocells are activated SA led on Check that the photocells are clean and operating correctly The automatic closing does not work Check that the TC trimmer is not set at the maximum External safety devices not activating Incorrect connections between the photocells and the control panel Connect N C safety devices together in series
10. M M Motor encoder connection Connect the motor and encoder to the control panel by means of the supplied cables BAT BATK4 2x12 V 1 2 Ah Battery operating The batteries are kept charged when the power supply is on If the power supply is off the control panel is powered by the batteries until power is re established or until the battery voltage drops below the safety threshold If this occurs the control panel turns off WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries NOTE the operating temperature of the rechargeable batteries is approximately 5 C 40 C IP1982EN 2012 03 22 7 ADJUSTMENTS Description OFF ON DIP1 Command 1 5 operation NOTE it also sets operating mode of the plugin cards connected on AUX Step by step Opening DIP2 Motor installation position The installation position is intended by viewing the automation from the side be ing examined Central or right side Left side DIP3 Restore automatic closing time 50 100 DIP4 Automation status at power on Indicates how the control panel considers automation when powered up Open NOTE with limit switches installed preferably set DIP4 OFF Closed NOTE if the automatic clos ing function is not used preferably set DIP4 ON DIP5
11. ence of flammable gas or fumes rep resents a serious threat to safety The safety devices photocells sensitive edges emergency stop etc must be installed taking into account the provisions and the directives in force Good Working Methods the installation area the functional logic of the system and the forces developed by the automation Before making power connections check that the rating corresponds to that of the mains supply A mul tipolar disconnection switch with a contact opening gap of at least 3 mm must be included in the mains supply Check that upstream of the electrical installation an adequate residual current circuit breaker and an overcurrent cut out are fitted When requested connect the automation to an effective earthing system carried out as indicated by current safety regulations During installation maintenance and repair operations cut off the power supply before opening the cover to access the electrical parts To handle electronic parts wear earthed antistatic conductive bracelets The manufacturer of the mo torisation declines all responsibility in the event of components which are not compatible with the safe and correct operation of the product For repairs or replacements of products only original spare parts must be used 3 IP1982EN 2012 03 22 2 EC DECLARATION OF CONFORMITY Manufacturer DITEC S p A Address via Mons Banfi 3 21042 Caronno P lla VA ITALY declares that the control panel ETHBOX
12. f power supply Commands Outputs and accessories Adjustments Radio receiver operation Start up 0 Troubleshooting seo OS os A 1 e eo CAPTION Tris symbol indicates instructions or notes regarding safety issues which require particular attention E This symbol indicates informations which are useful for correct product function ET This symbol indicates instructions or notes intended for technical and expert personnel I All right reserved All data and specifications have been drawn up and checked with the greatest care The manufacturer cannot however take any responsibility for eventual errors ommisions or incomplete data due to technical or illustra tive purposes IP1982EN 2012 03 22 2 1 GENERAL SAFETY PRECAUTIONS This installation manual is intended for qualified personnel only The installation the power connections and the settings must be completed in conformity with Good Working Methods and with the regulations in force Before installing the product carefully read the instructions Bad installation could be hazardous The packaging materials plastic polystyrene etc should not be discarded in the environment or left within reach of children as these are a potential source of hazard Before beginning the installation check that the product is in perfect condition Do not install the product in explosive areas and atmospheres the pres
13. na NOTE to connect the external antenna to the control panel use a coaxial cable type RG58 max 10 m Check that the storage module is inserted on COM connector of the control panel Up to 200 remote controls can be stored in the storage module WARNING if the radio receiver on the control panel is not used set JR4 OFF and remove the storage module Transmitter storage press the PRG button on the radio receiver or on the control panel the SIG LED lights up make a transmission by pressing one of the desired CH buttons of the transmitter within the range of the radio receiver The transmitter is now stored During this phase the SIG LED flashes When the SIG LED is again lit up it is possible to validate another transmitter Validate all the new transmitters by mak ing a transmission as indicated you automatically exit the procedure 10 s after the last transmission or you can press the PRG button again the SIG LED goes off Up to four CH keys of a single remote control can be stored if only one any CH key of the remote control is stored command 1 5 step by step opening is carried out from two to four CH keys of a single remote control are stored the functions matched with the CH keys are as follows CH1 command 1 5 step by step opening CH2 partial opening command CH3 command to switch on off the courtesy light CH4 stop command equivalent to impulsive command 1 9 Transmitter cancellation
14. st adjustment The control panel is equipped with a safety system that stops motion if an obstacle is encountered during an opening operation and inverts the movement during a closing operation R1 MIN gives maximum obstacle sensitivity minimum thrust R1 MAX gives maximum thrust LED On Flashing IN Receipt of command or change in status of a dip switch SIG Transmitter enabling storage phase Reception of a radio transmission of a stored transmitter e Reception of a radio transmission of a not stored transmitter 2 eeeeecececece Cancellation of transmitters in progress e e Memory damaged 11 0 11 limit switch contact is open SA At least one of the safety contacts is open e Safety test failure terminal 41 Operations count performed only when con trol panel is switched on 1000 operations ex 10000 operations 12 0 12 limit switch contact is open POWERALARM Power supply on e e Encoder not working IP1982EN 2012 03 22 8 RADIO RECEIVER OPERATION ANT The control panel is equipped with a radio receiver with a frequency of 433 92 MHz The antenna consists of a rigid wire 173 mm long connected to the ANT clamp It is possible to increase the range of the radio by connecting the antenna of the flashing lights or by installing the tuned BIXAL anten
15. tus lamp 1 69 13 24 V 3 W Automation status lamp proportional The light switches off when the automation is closed the light switches on when the automation is open the light flashes with a variable frequency while the automation is operating 0 14 LAMPH 24 V 25 W Flashing light Activated during opening and closing operations NOTE two LAMPH flashing lights with 24 V 15 W bulbs can be connected LUXKBOX 230 V 25 W Internal courtesy light A courtesy light that turns on for 180 s with every opening total or partial step by step and closing command can be connected in series to the NO contact ro O0 20 465 oO 230 V 100 W External courtesy light An external courtesy light that turns on for 180 s with every opening total or partial step by step and closing command can be connected AUX The control panel has one housing for plug in cards such as a radio receiver type magnetic loops etc Plug in card operating is selected using DIP1 WARNING the plug in cards must be inserted and removed with the power supply disconnected COM BIXMR2 The storage module allows remote controls to be stored If the control panel is replaced the BIXMR2 storage module being used can be inserted in the new control panel WARNING the storage module must be inserted and removed with the power supply disconnected

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SGH-i550 Kasutusjuhend  TomTom 1505 GPS Receiver User Manual  ALPHADRIVE ADZ  RIRs 400VE RIRs 700VE RIRs 1500VE  Recortadora/Cortadora de Maleza ALTO  LEX206C USB - YAMAKI sonido profesional  Complete Owner`s and Service Manual for the Universal  Bedienungsanleitung User manual EL 821 - spot  