Home

PTZ10EXT manual

image

Contents

1. PTZIOEXT EXTERNAL PAN TILT AND ZOOM DOME CAMERA USER MANUAL esp www espuk com Product Overview FEATURES 10x optical zoom IR Night vision up to 50m 360 degree endless pan rotation Auto flip function to aid tracking of subjects beneath camera Control protocol auto detect Supports Pelco D P Hik and Dahua control protocols Supports baud rates of 2400 4800 9600 e 220 location presets with scan tour facilities Auto patrol function can be engaged when idle DIMENSIONS CONNECTION OVERVIEW See page 6 for further wiring information Power supply cable 12V 2A Connect to 12V power supply Video cable BNC Connect to DVR or monitor coo Control cable RS485 Connect to PTZ controller Pre Installation Guidance SITING YOUR PTZ CAMERA Do not install your PTZ camera in any of the following locations e n areas where humidity reaches gt 90 Near a boiler flue or air conditioning outlet n environments high in smoke or dust Avoid directing the camera towards very strong light sources such as the sun You should also avoid high output light sources such as floodlighting Prolonged exposure to strong light sources damage the camera s image sensor resulting in bleached colours ILLUMINATION Multiple light sources from different directions will always produce better results than relying only on the IR night vision especially when trying to read vehicle number plat
2. TZ DISPLAY s EXIT SYSTEM SETTING CAMERA MOVEMENT CONTROL PRESET PATROL TRACK PATTERN REMOVE EXIT REMOVE PRESET PATROL TRACK PATTERN EXIT IR LED SETTING CONTROL MODE AUTO LED ON VALUE 220 LED OFF VALUE 170 BRIGHTNESS LOW POWER CURRENT LEVEL 50 EXIT CAMERA SCREEN TIPS ON AUTO ICR OFF AUTO FOCUS ON FOCUS SPEED FAST DIGITAL ZOOM ON ZOOM SPEED FAST EXIT MOVEMENT CONTRO AUTO FLIP ON PROPORTIONPAN OFF PARK TIME NO PARK ACTION NO POWER ACTION NO CONTROLSPEED HIGH AB SCAN SETTING AB SCAN PATH I ARC AB SCAN SPEED HIGH LIMIT STOP OFF LIMIT SETTING THE NORTH SETTING EXIT PRESET NUMBER 1 LABEL DEFAULT EDIT REMOVE EXIT PATROL TRACK NUMBER EDIT PREVIEW REMOVE EXIT PATTERN NUMBER 1 EDIT PREVIEW REMOVE EXIT OSD Menu Features MAIN MENU System Information Display system information Display Setting Configuration of on screen information System Setting Configuration of system parameters IR LED Setting Configuration of IR illumination parameters Restart Camera Restart the zoom module Reset Revert to factory default settings SYSTEM INFORMATION Protocol Set control protocol to Pelco Hik Auto Baud Rate Set control baud rate to 2400 4800 9600 Auto Hard Addr Display current address ID set by DIP switches 0 255 Soft Addr Configure a new address ID to override Hard Address 0 255 Enable Soft Addr Ena
3. ble the Soft Addr function Temperature Display current internal temperature of camera Version Display current firmware version DISPLAY SETTING Info Tip s Configure on screen information such as Preset and Pattern functions Can be set to never time out or1 5s time out PTZ Display s Configure on screen PTZ directional info Can be set to never time out or1 5s time out RESTART CAMERA Select to restart the zoom module RECOVER FACTORY SETTING Select to load all factory default settings power the camera down to take effect System Setting Menu Camera Movement Control Preset Patrol Track Pattern Remove Exit CAMERA Screen Tips Auto ICR Auto Focus Focus Speed Options for OSD screen tips focus and zoom functions Options for movement speed orientation scanning and movement limits Configure preset positions Configure patrol tracks Configure patrol patterns Remove presets patrols or patterns Leave OSD menu Enable or disable screen tips and on screen information Enable high light level compensation helps reduce glare from bright light sources e g car headlight and floodlight Enable or disable the AF feature Focus will be entirely manually controlled only recommended for troubleshooting Configuration of AF speed high med low Digital Zoom Enable digital zoom feature not available Zoom Speed Zoom speed setting fast slow MOVEMENT CONTROL Auto Flip Enable disable auto flip camera t
4. es in dark conditions If IR light is sourced from the same direction as the camera it is reflected directly back at the camera causing the number plate to appear as if illuminated overexposed Adequate ambient light sourced from different directions will eliminate this This applies to all cameras with built in IR POWER SUPPLY AND CABLING Recommended cable types based on a standard installation 200M max cable run Control cable Shielded control cable 0 5mm 24AWG Video cable RG59 120M CT100 or higher recommended for gt 120M Power cable Twin core minimum 0 2mm or higher Please ensure all cabling is kept at least 300mm from main high voltage cabling to avoid interference Multiple PTZ cameras operated from the same controller must be wired in parallel in a daisy chain layout For more information see page 6 MAINTENANCE Be aware that as PTZ cameras contain moving parts they are subject to more wear and tear than traditional fixed cameras Ensure that the lens is periodically cleaned as dust and dirt can cause the auto focus to function incorrectly Use a damp cloth to clean the lens do not use liquids or chemicals of any sort Installation 1 Mark out the holes for the 4 fixing 2 Drill holes and insert rawl plugs screws using template provided 3 Remove cover to access address baud 4 Replace cover and screw rate resistor switches see page 5 M4 SCREW 5 Thread cables through the bracket 6 I
5. nsert M4 screws into bracket to secure dome housing 7 Insert fixing screws and secure bracket 8 Connect cables see page 6 to wall Configuration DIP Switches CAMERA ID ADDRESS SETUP SWITCH SW1 PTZ cameras must be addressed with a unique number This number can be from 0 255 and is set in binary use the table below to manually set the address Visit http www binaryhexconverter com for more help to convert decimal to binary Once the camera is installed and the ID has been set up it can be changed without having to access the DIP switches It can be done from the camera menu system see page 6 for further details SWITCH SW1 Address Switch SW1 Setup SW1 1 SW1 2 SW1 3 SW1 4 Sw1 5 SW1 6 Sw1 7 SW1 8 1 On Off Off Off Off Off Off Off 2 Off On Off Off Off Off Off Off 3 On On Off Off Off Off Off Off 4 Off Off On Off Off Off Off Off 5 On Off On Off Off Off Off Off 6 Off On On Off Off Off Off Off 7 On On On Off Off Off Off Off 8 Off Off Off On Off Off Off Off 9 On Off Off On Off Off Off Off 10 Off On Off On Off Off Off Off BAUD RATE SWITCH SW2 All cameras operated from the same controller must all be configured to the same baud rate Lower baud rates will see fewer data errors and can be transmitted over longer distances than high baud rates Higher baud rates will be more responsive to user input Set your PTZ camera to the same baud rate as y
6. our controller or use the Auto Detect function which will configure this automatically Set using switches Sw2 1 and SW2 2 Baud Max transmission 2400 4800 9600 Auto Detect rate distance bmm cable 2400 1800M 4800 1200M 9600 800M EOL RESISTOR SWITCH SW2 ResistorOn Resistor Off When connecting PTZ cameras the built in 120 resistor should be connected on the last PTZ camera in the chain See page 6 for further details The resistor is connected via DIP switch SW2 4 4 ON Connections Earth wire 12V Power Supply DC Connector ur p U Tm BNC Connector Using a screened control cable is recommended for maximum protection against interference 12V DC Connect to power supply connect 230V mains supply to power supply RS485A Connect to PTZ controller or DVR RS485A RS485B Connect to PTZ Controller or DVR RS485B Earth wire Connect to control cable screen Ensure screen is earthed correctly Video BNC Connect to DVR or monitor input CONNECTING MULTIPLE PTZ CAMERAS Multiple PTZ cameras must have the RS485 control cable wired in parallel The last PTZ on the chain must have the 120Q resistor connected see page 5 PTZ PTZ 1 PTZ 2 PTZH3 End PTZ Controller POWER ON SELF TEST When first powered up the PTZ camera will perform the self test testing all motor functions This test takes approximately 12 seconds Once complete the PTZ camera is ready for use Ba
7. sic Operation SET RECALL PRESET POSITIONS 1 Set PTZ controller to the correct PTZ camera input PTZ ID press CAM 2 Use joystick to position zoom camera to chosen position 3 Input position number PRESET To recall a preset position input position number SHOT PRESET FUNCTION ACCESS Some of the commonly used functions on the PTZ camera can be accessed by entering certain preset numbers Press preset number then SHOT to access these functions Preset number Description of feature 95 Access main menu 98 High speed auto scan 99 Low speed auto scan 221 Set position A of A B line scan 222 Set position B of A B line scan 223 High speed A B scan 224 Medium speed A B scan 225 Low speed A B scan 231 238 Run patrol 1 8 241 244 Run mode scan 1 4 251 Set manual control to high speed 252 Set manual control to medium speed 253 Set manual control to low speed 254 Run motor calibration OSD MENU ACCESS AND NAVIGATION Menu function Method Enter OSD Menu Press 95 SHOT Move up down left right Move controller joystick Select Confirm Press OPEN Escape Back Press CLOSE OSD Menu Overview MAIN MENU SYSTEM INFORMATION DISPLAY SETTING SYSTEM SETTING IR LED SETTING RESTART CAMERA RESET EXIT SYSTEM INFORMATION PROTOCOL BAUD RATE HARD ADDR SOFT ADDR SOFT ADDR ENABLE OFF TEMPERATURE 30 VERSION 08130801 EXIT DISPLAY SETTING INFO TIPS s P
8. t to mimic a sequence of movement Number Select pattern to edit create Edit Create or edit pattern Preview Run preview of current pattern Remove Delete current pattern REMOVE Preset Delete all preset data Patrol Track Delete all patrol track data Pattern Delete all pattern data IR LED SETTING MENU Control Mode Control mode of IR Auto On Off LED ON Value Set LED on threshold LED Off Value Set LED off threshold Brightness low power Set brightness mode Brightness Quality Uniform Brightness Setting for highest illumination level Quality Setting for image clarity Uniform Setting for uniform brightness Current level Show current ambient light level 0 255 Technical Specifications Rated Voltage 12V DC Max current 1 25A IR effective distance 50M Protection IP66 Pan rotation 360 Endless rotation Speed Pan 0 6 200 s Tilt 3 5 30 s Working conditions 10 C 50 C Elite Security Products Telephone 01527 515150 Unit 7 Target Park Shawbank Rd Fax 01527 5151 43 Lakeside Redditch B98 8YN email info espuk com www espuk com
9. urns 180 when following a Proportion Pan Park Time Park Action Power Action Control Speed AB Scan Setting AB Scan Path AB Scan Speed Limit Stop Limit Setting The North Setting subject passing underneath the camera to aid tracking Enable disable proportion pan camera control speed is lowered when zoomed in to aid tracking Set park time idle time in seconds 0 255 Set park action when camera is idle Preset Pattern Patrol Scan Set power action when camera is powered up Preset Pattern Patrol Scan Set camera control speed High Medium Low Setup points A and B for AB Scan Set AB scan path I Arc O Arc l Arc front facing O Arc rear facing Set AB scan speed High Medium Low Enable disable limit stop option Overrides the auto flip function when enabled Set limit setting parameters defines the area that the camera may cover Set orientation north position for correct OSD directional information PRESET Preset camera positions Number Select preset to be edited 0 220 Label Set name of preset not available Edit Position camera zoom to set preset position Remove Delete current preset PATROL TRACK A group of sequenced preset positions Number Select patrol track to be edited Edit Create or edit a patrol track Preset preset no Speed panning speed Time dwell time Preview Run preview of current patrol track Remove Delete current patrol track PATTERN Records user inpu

Download Pdf Manuals

image

Related Search

Related Contents

WMS 40 PR。 FLE絲    Samsung ST95 Käyttöopas  Install Manual  WHEELS - Canyon  取扱説明書 - EIZO  König CMP-MOUSEFOLD2 mice  DP-600 - Accuphase  A.P.E. Vape Desktop User Manual  

Copyright © All rights reserved.
Failed to retrieve file