Home
KBox A-101
Contents
1. Fig 23 Left nght mounting bracket for wall table mounting www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide preliminary Version 1 00 A 2 1 Fig 25 Detail of the keyhole mounting slots www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide Version 1 00 9 2 2 Bracket for Cabinet Mounting This bracket Fig 26 allow you to mount the KBox A 101 in a vertical orientation in a cabinet e g industrial cabinet corresponding to the desired orientation The mounting of the KBox A 101 into a cabinet is permitted only in a vertical orientation You may choose which side should be facing up or down two operating positions The bracket must be mounted on the rear of the KBox A 101 according to the desired operating position so that the keyhole mounting slots of the bracket should be located above the unit see Fig 27 and Fig 28 Please observe that by using of this kind of bracket the interfaces WLAN and GPIO on the rear side of the KBox A 101 are not available Before mounting the cabinet bracket Fig 26 to the KBox A 101 you have to disassemble LJ the WLAN and GPIO modules and interface connectors if you have ordered the KBox A 101 equipped for WLAN and GPIO functionality U the cover protection plates of the WLAN and GPIO interface slots if you have ordered a KBox A 101 without WLAN and GPIO function Please refer to the subsection 9 3
2. P LS 0 KBox A 101 User s Guide Version 1 00 12 Standard Interfaces Pin Assignments KBox A 101 User s Guide preliminary Version 1 00 12 1 7 DP Connector DisplayPort Fit sainan TO onon ottone em rea fe C o eee Lo hora me 12 1 8 USB 2 0 Port 12 1 9 USB3 0 Port VCC fused 900 mA max StdA_SSRX Data StdA_SSRX Data GND_DRAIN GND StdA_SSTX StdA_SSTX www kontron com 13 Technical Support KBox A 101 User s Guide Version 1 00 13 Technical Support For technical support please contact our Technical Support department e mail support keu kontron com Web http www kontron com support Make sure you have the following information on hand when you call e the unit part id number PN e the serial number SN of the unit the serial number can be found on the type label placed on the right side of the system Be ready to explain the nature of your problem to the service technician If you have questions about Kontron Europe or our products and services you can reach us by the above mentioned telephone number and on e mail address or at www kontron com 13 1 Returning Defective Merchandise Please follow these steps before you return any merchandise to Kontron Europe 1 N Download the corresponding form for returning a device with an RMA No RMA Return of Material Authorization from our website www kontron com Support RMA Inform
3. H A ep A A 44 3 z a 4 Le Ta KC Le fr Vv T N pi A INN A PAS ATI ESED VA wl a Wf ain User s Guide Version 1 00 1056 1828 3 kontron This page is intentionally left blank www kontron com 1 Table of Contents KBox A 101 User s Guide Version 1 00 1 Table of Contents A Table OF CONTENTS sescsseccssscnssasencsonsascnastencewccusassssuiunaenonsensesacsessenseenciscssesenoscuuedonsnsnssieasssasaeaedwacarossasesasness 1 DAG Or e re 2 et Tee EE 4 3 Important UE d Tan LC 6 SdL Wel ANG AO CC EE 6 3 2 Exclusion of Accident Liability Obligation EENEG 3 3 Liability Limitation Exemption from the Warranty Obligation iii 6 A Savery INSEVUEHOMS ccccdcacnccnscssncsncwac cedeaudacedascanisctadescnceusscsdadeesoawsndsosiescandcosseseacsnedessanwsecsosdetedaduascnsedessoncsses 7 Aa RECTO ane US EE 7 A DE GVO UCU IMCEMOUG erae RENE A 7 E ee Ee N ER 7 5 Electromagnetic Compatibility Class A Device ccccccccccscccccccccccccsccccccccsccescccscccsccscsccesscccsccessccsscsescoes 8 5 1 Electromagnetic Compatibility EU EE 8 Oo Us Statement USA EE 8 5 MORE 8 6 SCOPE OF Delivery SE 9 6 1 peard ee ee ee 9 7 Product UE e elen EE 10 Aol EE 11 7 1 1 DCIN Direct Current Renne e EE 11 Tre COMPOS and TNGICALONS sesioan a erat 11 7 1 3 External Interfaces of the SBC at the Front Aude 13 7 1 4 Optional Interfaces on the Front Snde rire re rire re vere re cere nie ieri ce
4. 1 Close all applications Shut down the system properly and disconnect the power cord from the power source Disconnect all peripherals 2 The KBox A 101should lay on a flat clean surface with the top side cooling fins facing downwards 3 Unscrew the 8x countersunk screws M3x8 IS014581 torx see Fig 19 pos 4 that secure the cover Put the screws aside for later use Lift the cover with the mounted HDD SSD carefully 4 Remove the HDD SSD data cable und power cable from the SBC and put the cover with mounted HDD SSD aside Now allinternal components inside the chassis and on the cover can be accessed 5 For closing the KBox A 101 proceed in reverse order Reconnect the data cable and the power cable of the HDD SSD mounted on the cover to the SBC place the cover on the cassis and secure the cover with the countersunk screws removed in step 3 see Fig 19 pos 4 www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide preliminary Version 1 00 9 3 2 Configuration of the optional RS422 RS485 Port In order to change the factory configuration of the RS422 RS485 port see also subsection 7 1 4 1 RS422 RS485 Serial Interface proceed as follows The new port configuration has to be set before the KBox A 101 is installed on a panel or into an industrial cabinet The system must be disconnected from the power source Disconnect all peripherals Before you begin ensure that you have a clean
5. flat and ESD safe surface to work on 1 Open the chassis of the KBox A 101as described in subsection 9 3 1 Opening and Closing the KBox A 101 2 The DIP switches for setting the SJA1000 base address SJA interrupt and NVRAM operation mode are located on the LPCtoCAN adapter see Fig 32 3 By use of an insulated thin tool e g screwdriver or a stylus set the DIP switches to the up for ON or down for OFF position corresponding the needed port configuration DIP switches DIP1 DIP8 WI ON sce ee 2 EE E E Ll2 oe 4 D 8 fie di Fig 32 DIP1 DIP8 switches shown with factory settings n ZE ii 4 Close the chassis of the KBox A 101 as described in subsection 9 3 1 Opening and Closing the KBox A 101 www kontron com 10 Maintenance and Prevention KBox A 101 User s Guide Version 1 00 10 Maintenance and Prevention Equipment from Kontron Europe requires only minimum servicing and maintenance for problem free operation U For light soiling clean the KBox A 101 with a dry cloth Carefully remove dust from the surface of the cooling fins of the chassis using a clean soft brush LJ Stubborn dirt should be removed using a mild detergent and a soft cloth www kontron com 11 Technical Data 11 Technical Data KBox A 101 Installed SBC Processor Storage Media Interfaces Internal Onboard Slots Controls at the front side Indicators at
6. not included and the countersunk M3x8 Torx IS014581 screws Longer screws can damage the device The platform must be firmly attached to a clean flat and solid mounting surface Use proper fastening materials suitable for the mounting surface Ensure that the mounting surface type and the used mounting solution safely support the load of the KBox A 101 platform and the attached components It is recommended to use screws with a diameter of 5 mm 0 197 The screw type and length as well as accessories like anchors depend on the type and the consistence of the mounting surface table wall cabinet etc Please follow the local national regulations for grounding The voltage feeds must not be overloaded Adjust the cabling and the external overcharge protection to correspond with the electrical data indicated on the type label The type label is located on bottom side of the unit refer to Fig 19 pos 6 www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide preliminary Version 1 00 9 1 KBox A 101 Desktop Version The KBox A 101 can also be ordered as a desktop version The self adhesive rubber feet included have to be attached to the bottom side of the device When setting up the device pay attention to the range of restriction areas around the KBox A 101 refer to the subsection 11 2 1 KBox A 101 Desktop Dimensions 123456789 USB 3 0 USB 2 0 DISPLAY PORT l PWR owen La
7. 1 Opening and Closing the KBox A 101 PE mn Fig 27 KBox A 101 with assembled bracket for cabinet mounting Fig 28 Keyhole slot dimensions www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide preliminary Version 1 00 9 2 3 DIN Rail Mounting Clip The DIN Rail mounting clip Fig 29 allows you to mount the KBox A 101 to a DIN Rail e The DIN Rail mounting clip make possible to operate the KBox in two operating positions You may choose L the mounting orientation witch side is facing up or facing down The DIN Rail mounting clip has to be mounted to the bottom side of the KBox A 101 corresponding to the desired orientation refer to Fig 30 and Fig 31 Fig 31 Details of the DIN Rail mounting clip www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide Version 1 00 9 3 Handling internal Components This section contains important information that you must read before accessing the internal components You must follow these procedures properly when handling any board components of the KBox A 101 Before installing removing an add on card please pay attention to the following information Please observe the General Safety Instructions for IT Equipment provided with the system and the installation instructions in this manual see also chapter 4 and 9 The installation removal of add on cards may only be performed by a qualified person acco
8. 101 User s Guide preliminary Version 1 00 11 4 CE Directives and Standards CE Directive Elektrical Safety General Product Safety Directive GPSD 2001 95 EC Low Voltage Directive LVD 2006 95 EC Electromagnetic EMC Directive 2004 108 EC Compatibility EMC CE Marking CE Directive 93 68 EEC RoHS II Directives 2011 65 EU Elektrical Safety Harmonized Standards CB Scheme CB Certification Information technology equipment Safety Part 1 General requirements EN 60950 1 A11 U S A CANADA To meet UL60950 1 CSA C22 2 No 60950 1 7 Harmonized Standards Generic emission standard for industrial environments Emission EN 61000 6 4 Generic standards Immunity for industrial environments Immunity EN 61000 6 2 FCC 47 CFR Part 15 Class A CANADA ICES 003 Class A www kontron com 12 Standard Interfaces Pin Assignments KBox A 101 User s Guide Version 1 00 12 Standard Interfaces Pin Assignments Low active signals are indicated by a minus sign 12 1 1 Power Input Connector Pin Signal Name 3 pin POWER SUBCON male OV input NC 24 VDC input m Data Carrier Detect Receive Data Transmit Data i Data Terminal Ready Signal Ground Co Data Set Ready 0000 0000 O Request to Send f DI Clear to Send Oo CO N On Wo KR WW N Ring Indicator www kontron com 12 Standard Interfaces Pin Ass
9. 2 Introduction Kontron Europe would like to point out that the information contained in this manual may be subject to technical alteration particularly as a result of the constant upgrading of Kontron Europe products The attached documentation does not entail any guarantee on the part of Kontron Europe with respect to technical processes described in the manual or any product characteristics set out in the manual Kontron Europe does not accept any liability for any printing errors or other inaccuracies in the manual unless it can be proven that Kontron Europe is aware of such errors or inaccuracies or that Kontron Europe is unaware of these as a result of gross negligence and Kontron Europe has failed to eliminate these errors or inaccuracies for this reason Kontron Europe expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every individual case In cases of doubt please contact Kontron Europe This manualis protected by copyright All rights are reserved by Kontron Europe Copies of all or part of this manual or translations into a different language may only be made with the prior written consent of Kontron Europe Kontron Europe points out that the information contained in this manual is constantly being updated in line with the technical alterations and improvements made by Kontron Europe to the products and thus this manual only reflects the technica
10. Wigs 2628 ae keto ea Din et TEE Fig 27 KBox A 101 with assembled bracket for cabinet MOUNTING e 27 Fige 28 Keyhole slot dimension EENEG SEHR TEE Fig 30 Tapped holes at the bottom of the KBox for fixing the DIN Rail mounting clip 28 Fig 31 Details of the DIN Rail mounting EES Fig 32 DIP1 DIP8 switches shown with factory settings nn 30 Fig 33 Dimensions in the front CET Fig 34 Dimensions in the side view desktop with optional antennal A Fig 35 Dimensions in the top side view desktop A Fig 36 Dimensions in the front view wall or table mounting AR Fig 37 Dimensions in the side view wall or table mounting AR Fig 38 Dimensions in the top view wall or table mounting e BO Fig 39 Detail for keyhole wall or table mounting A Fig 40 Dimensions in front view for KBox A 101 with bracket for cabinet mounting Al Fig 41 Dimensions in side view when using the bracket for cabinet mounting side with cooling fins A8 Fig 42 Dimensions in rear side view when using the bracket for cabinet mounting A Fig 43 Detail for keyhole bracket for cabinet mounting A Fig 44 Dimensions in front view by use of the DIN Rail cp 39 Fig 45 Dimensions in side view by use of the DIN Rail Clip A Fig 46 Dimensions in bottom view by use of the DIN Rail Clip Al Fig 47 Ditails with dimensions of the DIN Rail mounting clip 40 www kontron com 3 2 Introduction KBox A 101 User s Guide preliminary Version 1 00
11. are reserved for cable connections see Fig 34 RESTRICTION AREA air circulation AAAAAAAAAAAAAAAAAAAAARAANAAAAADA IS ROA KH EJ ia e OCD Kg 65 6 Fig 33 Dimensions in the front view desktop www kontron com 11 Technical Data KBox A 101 User s Guide preliminary Version 1 00 173 RESTRECTED AREA for cable connections RESTRECTED AREA for cable connections Fig 34 Dimensions in the side view desktop with optional antenna Fig 35 Dimensions in the top side view desktop www kontron com 11 Technical Data KBox A 101 User s Guide Version 1 00 11 2 2 Dimension for Wall and Table Mounting IS For a sufficient air circulation around the device we recommend not to place mount or operate any other devices within the red marked restriction area all around the cooling fins of the chassis see Fig 36 The restriction areas marked with 100 mm at the front and rear side of the platform are reserved for cable connections see Fig 37 RESTRICTION AREA air circulation 150 nS Sa o 65 o sie Fig 36 Dimensions in the front view wall or table mounting 173 si _r _ RESTRICTION AREA for cable connections Fig 37 Dimensions in the side view wall or table mounting www kontron com 11 Technical Data KBox A 101 User s Guide prelimin
12. des Fig 17 Obere Seite des Fig 18 Rechte Seite des Chassis Chassis Chassis 1 Cooling fins of the chassis on the left side 3 Warning sticker Hot Surface 2 Cooling fins of the chassis on the top side 4 Cooling fins of the chassis on the right side IS To provide sufficient heat dissipation for the cooling of the KBox A 101 platform never cover the cooling fins of the chassis Do not place any objects onto the device Please observe the warning label Hot Surface see Fig 7 and Fig 17 pos 3 in the area of the cooling fins of the chassis The KBox A 101 chassis may be hot during operation and should not be touched without taking care There is a risk of burns The material on bottom surface of the enclosure interior where the KBox A 101 is to be mounted shall keep at least flammability class UL 94 5VB Don t put flammable materials under the device www kontron com 7 Product Description KBox A 101 User s Guide Version 1 00 7 4 Bottom Side At the bottom side are located the type label the inspection status label and if applicable the license sticker G B G a 123456789 DL Type KBox A 101 Z 000 6 Fig 19 Bottom side shown as desktop version 1 Frontside with external interfaces of the SBC 4 Countersunk screws M3x8 IS014581 torx for the mounting of the bottom part of the chassis and the 2 Rubber feet of the desktop version Brackets for wall table mounting 3 Counters
13. fon Jon fon Zems z0 o o oe Jo L n A Joe J Bms fon oe o or Bm oo dom _ _ DIP5 DIP6 DIP7 and DIP8 settings in order to set the needed timeout and min baud rate 7 1 4 2 DIP Switch Settings SW1 for LPCtoCAN Adapter The DIP switch is for setting the SJA1000 base address the SJA interrupt and the NVRAM operation mode HHHAAH EEERBEE H H H H H H H H Default setting Color marking Default setting for KBox A 101 in the following tables www kontron com 7 Product Description SJA Base Address SW1 1 3 Switch OFF OFF 0x340 to 0x35F fort fon fon Jaeger fon ort for ox200 0 x2iF fon ort on oriaotooxi5F __ malen __ fon ow on ori00 0 oxi SJA Interrupt SW1 4 6 Essex disabled D forF fon me orr fon for ja on fore fore fr NVRAM Operation Mode SW1 7 8 Switch oe 7 for fon ome m OFF Ween __ fox Ja Nemoryat 00000 KBox A 101 User s Guide preliminary Version 1 00 Not useable for KBox A 101 Not useable for KBox A 101 www kontron com 7 Product Description KBox A 101 User s Guide Version 1 00 7 2 Rear View asili ina ANTENNA 1 ANTENNA 2 G komron ie oS amp Q Fig 14 KBox A 101 rear view with optional GPIO interface 1 Covered cutout for Reverse RP SMA connector 4 Optional GPIO interface routed from the on for optional WLAN antenna board connector Mini PCIe WLAN card and 2 antennas are
14. the front side DC IN Connector at the front side Power consumption per Slot Mini PCIexpress Rated Voltage Range KBox A 101 User s Guide preliminary Version 1 00 Interfaces at the front side Interfaces at the rear side 1x DisplayPort 1x COM 1 RS232 4x USB 2x USB 2 0 2x USB 3 0 2x LAN 10 100 1000Mbps Optional Optional 1x Fieldbus PROFIBUS or CAN bus 1x WLAN with 2x antenna connector 1x COM 2 RS232 or RS422 485 1x GPIO interface 1x full Size mini PCIe x1 for optional WLAN card mSATA port Power button Power LED HDD LED 3 pin DC input connector approx 2 5 kg See type label 24 VDC 20 via Phoenix connector e The corresponding document Configuration Guide and the manual of the installed SBC can be t downloaded from our web site www kontron com by selecting the product www kontron com 11 Technical Data KBox A 101 User s Guide Version 1 00 11 1 Electrical Specifications The corresponding electrical specifications for your KBox A 101 can be found on the type label of the system 11 2 Mechanical Specifications 11 2 1 KBox A 101 Desktop Dimensions IS For a sufficient air circulation around the device we recommend not to place mount or operate any other devices within the red marked restriction area all around the cooling fins of the chassis see Fig 33 The restriction areas marked with 100 mm at the front and rear side of the platform
15. 01 front view 1 DCIN power connector 4 Controls and indicators 2 External connectors of the installed SBC 5 Rubber feet 3 Cooling fins 6 Externalinterface connectors optionally routed from the on board interfaces 7 1 1 DC IN Direct Current Connector The 3 pin connector Fig 9 pos 1 provides the power connection of the KBox A 101 to the appropriate main power supply LI DC power supply using a corresponding power cord only the Phoenix connector is included Please observe the section 8 1 Connecting to DC Main Power Supply 7 1 2 Controls and Indicators 1 Power button 2 Power LED 3 HDDLED Fig 10 KBox A 101 Controls and indicators www kontron com 7 Product Description KBox A 101 User s Guide preliminary Version 1 00 7 1 2 1 Power Button Press this button Fig 10 pos 1 to switch the system on or off Prerequisite The KBox A 101 has to be connected to an appropriate main power supply DC A Even when the system is turned off via the power button there is still a standby voltage of 5 VSb on the SBC The unit is only completely disconnected from the DC mains when the power cord is disconnected either from the mains or the unit Therefore the power cord and its connectors must always remain easily accessible 7 1 2 2 Power and HDD LED The power LED Fig 10 pos 2 and the HDD LED Fig 10 pos 3 are located on the front side of the KBox A 101 and indicate the system sta
16. 1 I Fig 21 Connecting the KBox A 101 to a DC main power supply via DC power cable To connect the KBox A 101 to a corresponding DC main power supply please perform the following steps 1 Connectthe DC power cord with the Phoenix power plug installed to the DC input connector Fig 9 pos 1 Fig 11 pos 2 of the KBox A 101 The DC input connector is located on the front side and is marked 24V 2 The DC main power supply must be switched off via a 2 pole disconnecting device to make sure that no voltage is present at the terminals during the connecting procedure 3 Connectthe other end of the DC power cord to the connections of the DC main power supply Pay attention to the polarity of the connections 4 Switch on the DC main power supply via the disconnecting device A It must be ensured that the system can be powered ON and OFF via a readily accessible two pole disconnecting device that shall be incorporated in the building installation wiring e g overload protection switch www kontron com 8 Starting Up KBox A 101 User s Guide preliminary Version 1 00 8 2 Operating System and Hardware Component Drivers Your system can be supplied optionally with a pre installed operating system If you have ordered your KBox A 101 with a pre installed operating system all drivers are installed in accordance with the system configuration ordered optional hardware components Your system is fully operation
17. 10 Fig 5 Front side VIEW e 10 WEIIECcAErAe e e o_e ro e ee Te stdl 0 e e eeeeeeeessecguUa ERI OSARE Ei Ei se 10 Kee 10 Fig 9 KBox A 101 front view LL Fig 10 KBox A 101 Controls and indicators deasectupescantaceuvsigcesseranestnasecbanieuianectndaioncieniancainaaaaennenise II Fig 11 External interfaces of the integrated St 13 Fig 12 Optional external interfaces routed from the onboard ports on the front side 14 Fig 13 Onboard DIP switch SW1 with DP1 up to DP8 for RS422 RS485serial communication settings 14 Fig 14 KBox A 101 rear view with optional GPIO interface e 17 Fige 15s WLAN CEE lel sactrsustacoceainavsuesiaditvaunde vane EE ASTE eege 18 2 www kontron com 1 Table of Contents KBox A 101 User s Guide Version 1 00 Fi 17 ODere Saite des E 18 PoR E E EENS Fig 19 Bottom side shown as desktop version Fig 20 Phoenix power plug terminal with plus and minus marking e 20 Fig 21 Connecting the KBox A 101 to a DC main power supply via DC power cable scscssssseseesessessesessesseseeseseesene 21 Fig 22 KBox A 101 as Desktop unit with rubber feet cccsscssssssccssssssscsscsssssseessesssscsecssseessesssscsecssnsseeesenssens Z Fig 24 KBox A 101 with mounted wall mounting brackete e 26 Fig 25 Detail of the keyhole mounting Slots sccscssssssscssesssssseessesssecsscssssessessescssessessseessessssesecsssseseeseensens 26
18. 3 3 Serial Port COM 1 The serial port COM 1 Fig 11 pos 5 consists of a 9 pin RS 232 configured D SUB connector that allows the connection of a serial peripheral 7 1 3 4 DisplayPort An external digital display can be connected to the DisplayPort connector Fig 11 pos 6 www kontron com 7 Product Description KBox A 101 User s Guide preliminary Version 1 00 7 1 4 Optional Interfaces on the Front Side Came ae FIELDBUS COM 2 Fig 12 Optional external interfaces routed from the onboard ports on the front side The optional interfaces Fieldbus and COM 2 on the front side of the KBox A 101 must be ordered separately The following interfaces are available e Fieldbus interface LPCtoCAN or PROFIBUS Please note With PROFIBUS optional WLAN is not available e COM 2 interface RS232 or RS422 485 non isolated 7 1 4 1 RS422 RS485 Serial Interface The optional serial RS422 485 interface Fig 9 pos 6 Fig 12 consists of a 9 pin D SUB connector The interface can be configured via an on board DIP switch SW1 for RS422 or RS485 serial communication The optional settings SW1 for RS485 mode communication allow the system s operation either in full duplex mode or in half duplex mode see tables on the next page While running in RS485 half duplex mode the system stays permanently in a receiver mode The switch to transmission mode will be done automatically The user can determine if t
19. ACCESS AREA or to the RESTRICTED ACCESS LOCATION must be Suitably instructed and sufficiently informed about the associated dangers Important Instructions In order to setting up installing removing the KBox A 101 platform please observe the instructions described in this manual The device may be operated in all positions except with the upper side facing down Please observe all specified dimensions required for mounting included in the drawing with outline dimensions for the KBox A 101 platform The corresponding drawing can be downloaded from our web site www kontron com by selecting the product name When installing the KBox A 101 there must be at least 50 mm approximately 1 97 free space around the cooling fins to prevent the system overheating Leave at least 100 mm approximately 3 937 free space to the front and rear of the unit in order to have access to the interfaces to connect the peripherals and to operate the power button When mounted into a cabinet the cabinet must have adequate space for the KBox A 101 platform and corresponding spaces for air circulation and cable connections see also section 11 2 Mechanical Specifications Furthermore the cabinet must have a sufficient optionally active ventilation to prevent overheating The cooling fins of the chassis are not obstructed covered by any objects For mounting to a table to a wall or DIN Rail Use for mounting the system only the optional brackets
20. Canadian ICES 003 French Cet appareil num rique de la class A est conforme a la norme NMB 003 du Canada 8 www kontron com 6 Scope of Delivery KBox A 101 User s Guide Version 1 00 6 Scope of Delivery LI LI LI LI KBox A 101 corresponding to the ordered system configuration Rubber feet self adhesive Phoenix power plug connector for DC power supply with 2x UNC4 40 6 4 mm pan head screws General Safety Instructions for IT Equipment Optional Parts LI LI UU UU LU Mini PCIe WLAN card internally installed with 2x WiFi antennas or Mini PCIe PROFIBUS adapter LPCtoCAN adapter RS422 485 adapter GPIO adapter Two Brackets for wall table mounting Bracket for cabinet mounting DIN rail mounting clip 6 1 Type Label and Product Identification The type label product name serial number and the inspection status label of your KBox A 101 system are located on the bottom side of the device refer to Fig 19 pos 6 www kontron com 9 Fig 1 Front view with wall table mounting brackets Fig 2 Rear view with wall table mounting brackets 7 Product Description KBox A 101 User s Guide preliminary Version 1 00 7 Product Description The KBox A 101 expands the Kontron line of computers KBox series The KBox A 101 is equipped with a SBC Single Board Computer with Intel Atom Dual Core D2550 1 86 GHz processor The hardware system configuration and the robust con
21. al when you switch it on for the first time Please pay attention to the following note e Important information on the use of the pre installed WINDOWS 7 ULTIMATE FOR EMBEDDED SYSTEMS or WINDOWS 7 PROFESSIONAL FOR EMBEDDED SYSTEMS operating systems The terms and conditions for the use of the pre installed operating systems are specified in the document MICROSOFT SOFTWARE LICENSE TERMS You can download this document from our web site www kontron com by selecting Product Downloads tab Windows If you have ordered The KBox A 101 without a pre installed operating system you will need to install the operating system and the appropriate drivers for the system configuration you have ordered optional hardware components yourself You can download the relevant drivers for the installed hardware from our web site at www kontron com t by selecting the product Pay attention to the manufacturer specifications of the operating system and the integrated hardware components www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide Version 1 00 9 Setting Up the KBox A 101 In order to prevent personal injury and damage by direct or indirect contact with the hot surfaces of the chassis following requirements have to be implemented LI The KBox A 101 system should be mounted and installed into a SERVICE ACCESS AREA or into a RESTRICTED ACCESS LOCATION LJ Users which are admitted to the SERVICE
22. ary Version 1 00 Fig 38 Dimensions in the top view wall or table mounting e 10 0 11 0 A 2 1 Fig 39 Detail for keyhole wall or table mounting www kontron com 11 Technical Data KBox A 101 User s Guide Version 1 00 11 2 3 Dimensions for using the Bracket for Cabinet Mounting IS For a sufficient air circulation around the device we recommend not to place mount or operate any other devices within the red marked restriction area all around the cooling fins of the chassis see Fig 40 The restriction areas marked with 100 mm at the front and rear side of the platform are reserved for cable connections see Fig 41 RESTRICTION AREA air circulation 150 58 Fig 40 Dimensions in front view for KBox A 101 with bracket for cabinet mounting www kontron com 11 Technical Data KBox A 101 User s Guide preliminary Version 1 00 RESTRICTION AREA for cable connections 100 S o lt L lt LL em CC S 5 Zc SE E pas S Si D Es E Lo LUJ e 6 NE n ca CD Fig 41 Dimensions in side view when using the bracket for cabinet mounting side with cooling fins 254 0 10 0 11 0 B 2 1 Fig 43 Detail for keyhole bracket for cabinet mounting www kontron com 11 Technical Data KBox A 101 User s Guide Version 1 00 11 2 4 Dimension for KBox A 101 by using the DIN Rail Clip IS For a sufficient air
23. ation contact our Customer Service department to obtain an RMA No e mail service kontron com Ensure that you have received an RMA number from Kontron Customer Services before returning any device Write this number clearly on the outside of the package Describe the fault that has occurred Please provide the name and telephone number of a person we can contact to obtain more information where necessary Where possible please enclose all the necessary customs documents and invoices When returning a device e Pack it securely in its original box e Enclose a copy of the RMA form with the consignment Corporate Offices Europe Middle East amp Africa North America Asia Pacific Oskar von Miller Str 1 14118 Stowe Drive 17 Building Block 1 ABP intel 85386 Eching Munich Poway CA 92064 7147 188 Southern West 4th Ring Germany USA Beijing 100070 P R China Tel 49 0 8165 77 777 Tel 1 888 294 4558 Tel 86 10 63751188 Fax 49 0 8165 77 219 Fax 1858 677 0898 Fax 86 10 83682438 info kontron com info us kontron com info kontron cn www kontron com
24. circulation around the device we recommend not to place mount or operate any other devices within the red marked restriction area all around the cooling fins of the chassis see Fig 44 The restriction areas marked with 100 mm at the front and rear side of the platform are reserved for cable connections see Fig 45 RESTRICTION AREA l air circulation Fig 44 Dimensions in front view by use of the DIN Rail clip 173 RESTRICTION AREA for cable connections RESTRICTION AREA for cable connections a E _ 6 _ __ _ _ Fig 45 Dimensions in side view by use of the DIN Rail clip www kontron com 11 Technical Data KBox A 101 User s Guide preliminary Version 1 00 Fig 47 Ditails with dimensions of the DIN Rail mounting clip www kontron com 11 Technical Data KBox A 101 User s Guide Version 1 00 11 3 Environmental Specifications Operating Temperature 0 50 C 32 122 F with HDD and a sufficient air circulation 10 60 C 14 140 F with peripherals for extended temperature range Storage Transit Temperature 40 85 C 40 185 F Relative Humidity Operating 95 40 C non condensing Max Operation Altitude 3 048 m 10 000 ft Max Storage Transit 10 000 m 32 800 ft Altitude www kontron com 11 Technical Data KBox A
25. ety Instructions for IT Equipment the hints in this manual or eventually the warning signs label on the device 3 3 Liability Limitation Exemption from the Warranty Obligation In the event of damage to the device caused by failure to observe the included document General Safety Instructions for IT Equipment the hints in this manual or eventually the warning signs label on the device Kontron Europe shall not be required to honor the warranty even during the warranty period and shall be exempted from the statutory accident Liability obligation 6 www kontron com 4 Safety Instructions KBox A 101 User s Guide Version 1 00 4 Safety Instructions Please consider the instructions described in the included General Safety Instructions for IT Equipment 4 1 Electrostatic Discharge ESD Ae A sudden discharge of electrostatic electricity can destroy static sensitive devices or micro circuitry Proper packaging and grounding techniques are necessary precautions to prevent damage Always take the following precautions 1 Transport boards in static safe containers such as boxes or bags 2 Keep electrostatic sensitive parts in their containers until they arrive at the ESD safe workplace 3 Always be properly grounded when touching a sensitive board component or assembly 4 Store electrostatic sensitive boards in protective packaging or on antistatic mats 4 1 1 Grounding Methods The following measure
26. he automatic mode switch to transmission mode should be triggered by the RTS line or should be triggered by the last sent message using the TxD line If triggered by RTS has been selected then the RTS signal must be activated by the application software before transmission of the data packets starts and RTS signal has to be disabled again after termination of data transmission If TxD line will be used for the mode transceiver switch process the receiver device has to follow a timeout before starting Fig 13 Onboard DIP switch SW1 with DP1 up to DP8 for RS422 RS485senal communication settings In order to configure this interface for serial communication as RS422 or RS485 corresponding to your requirements set the switches of the DIP switch SW1 to ON or OFF factory settings are marked grey For accessing the DIP switch refer to the procedure described in the subsection 9 3 1 Opening and Closing the KBox A 101 SREL RS422 4 ChannelMole Jo o dO R5485 4 Wire Mode Bus Maste ON o n s 2 Wire Mode RIS on on on R5485 2 Wire Mode time Jon Jon Jo www kontron com 7 Product Description KBox A 101 User s Guide Version 1 00 SSC os SON DIP4 setting in order to activate or deactivate the termination resistor for RS422 and RS485 a oies qoiee oe qors em Il oe Joe on dom Jo oe Jon or ems Jo oe Jon fon Gem Il fon Joe or Fam Il fon Joe fon ess Jo fon Jon or sms Jo
27. ignments KBox A 101 User s Guide preliminary Version 1 00 12 1 3 Serial Port RS422 RS485 configured as RS422 4 Channel Mode Refer to subsection 7 1 4 1 RS422 RS485 Serial Interface Pin Signal Name TxD Transmit Data RxD Receive Data TxD Transmit Data RxD Receive Data O DND Signal Ground 0160 OOOO Ce RTS Request to Send RTS Request to Send CTS Clear to Send 0 CTS Clear to Send 12 1 4 Serial Port RS422 RS485 configured as RS485 4 Wire Mode Full Duplex Bus Master Refer to subsection 7 1 4 1 RS422 RS485 Serial Interface Pin Signal Name 9 pin D SUB Connector female Transmit Data Receive Data 0 Transmit Data Receive Data O Signal Ground 00000 OOOO co 0 www kontron com 12 Standard Interfaces Pin Assignments 12 1 5 Serial Port RS422 RS485 configured as RS485 2 Wire Mode Half Duplex Refer to subsection 7 1 4 1 RS422 RS485 Serial Interface Pin Signalname 9 pin D SUB Connector female NC GND Signal Ground NC NC NC NC 12 1 6 CAN Connector Refer to subsection 7 1 4 2 DIP Switch Settings SW1 for LPCtoCAN Adapter Pin Signalname 9 pin D SUB Connector male CANL galvanisch getrennt CANOV galvanisch getrennt NC NC NC CANH galvanisch getrennt NC NC www kontron com 0 00000 0000 co O 0 orali e e000 O
28. l Fig 22 KBox A 101 as Desktop unit with rubber feet www kontron com 9 Setting Up the KBox A 101 KBox A 101 User s Guide Version 1 00 9 2 Wall or Table or Cabinet Mount using the Brackets In order to mount the KBox A 101 to a wall vertical upright or longitudinal on a table horizontal or into a cabinet you may order the corresponding mounting brackets with keyhole shaped mounting slots or a DIN Rail mounting clip You can adapt your desktop KBox A 101 to a wall mount system by attaching the mounting brackets to the left and the right side of the KBox A 101 bottom side When setting up the device pay attention to the range of restriction areas around the KBox A 101 Refer to the subsection 11 2 Mechanical Specifications Please observe the General Safety Instructions for IT Equipment included and the installation instructions refer to the chapters 4 and 9 9 2 1 Brackets for Wall Table Mount These brackets Fig 23 are used to mount the KBox A 101 in a vertical a longitudinal or an upright orientation to a wall or horizontally to a table corresponding to the desired orientation e The wall mounting of the KBox a 101 is possible in the horizontal as well as in vertical orientation You may t choose the mounting orientation witch side is facing up or facing down four operating positions The two brackets are symmetrical and can be mounted on either the left or right see Fig 24 and Fig 25
29. l status of the products by Kontron Europe at the time of printing 2014 by Kontron Europe Printing and duplication even of sections is only permissible with the express approval of Kontron Europe GmbH Office Eching Oskar von Miller Str 1 85386 Eching Germany 4 www kontron com 2 Introduction KBox A 101 User s Guide Version 1 00 2 1 Symbols used in this Manual This symbol indicates the danger of injury to the user or the risk of damage to the product if the corresponding warning notices are not observed This symbol indicates a hot surface that should not be touched without taking care Ignoring this warning may lead to serious burns to the skin www kontron com 5 3 Important Instructions KBox A 101 User s Guide preliminary Version 1 00 3 Important Instructions This manual provides important information required for the proper operation of the KBox A 101 This chapter contains instructions which must be observed when working with the KBox A 101 3 1 Warranty Note Due to their limited service life parts which by their nature are subject to a particularly high degree of wear wearing parts are excluded from the warranty beyond that provided by law This applies to the CF card for example 3 2 Exclusion of Accident Liability Obligation Kontron Europe shall be exempted from the statutory accident liability obligation if the user fails to observe the included document General Saf
30. optional Countercunkscrews Mane S014581 torneo 2 Cooling fins on the top side of the chassis mounting the rear cover and the bracket for 3 Rubber feet cabinet mounting 7 2 1 GPIO Interface Option Optionally the KBox A 101 can be equipped with a GPIO General Purpose Input Output interface Peripheral devices can be controlled freely programmable via this interface Fig 14 pos 4 which consists of a 9 pin D SUB connector 7 2 2 WLAN Option Depending on the ordered system configuration the KBox A 101 an be equipped with WLAN WiFi hardware expansion with two antennas If you have ordered a system configuration including WLAN at the rear side two Reverse RP SMA connectors are installed Fig 14 pos 1 for screwing on the provided WLAN antenna During the installation of the KBox A 101 the antennas Fig 15 will be screwed on to the RP SMA connector Fig 14 pos 1 The antenna can be tilt and rotated in the appropriate position to get the optimal transmission and reception quality Fig 15 WLAN WiFi antenna 1 Reverse RP SMA antenna connector 2 Hinge for positioning the antenna www kontron com 7 Product Description KBox A 101 User s Guide preliminary Version 1 00 7 3 Chassis with Cooling Fins Three sides of the aluminum chassis Left upper and right side are covered with cooling fins The cooling fins provide heat dissipation during operation Fig 16 Linke Seite
31. rding to the description in this manual Before removing the cover of the device make sure that the device is switched off and disconnected from the power supply Before you upgrade the KBox A 101 with add on cards pay attention to the power specifications in chapter 11 Technical Data and make sure that the power consumption of the add on cards does not exceed 5 W per card Please follow the safety instructions for components that are sensitive to electrostatic discharge ESD Failure to observe this warning notice may result in damage to the device or the latter s ALA components Please observe the warning label Hot Surface see Fig 7 and Fig 17 pos 3 in the area of the cooling fins of the chassis The KBox A 101 chassis may be hot during operation and should not be touched without taking care There is a risk of burns IS Please pay attention to the manufacturer s instructions before installing removing an add on card 9 3 1 Opening and Closing the KBox A 101 In order to install or to remove optional hardware or to change the DIP switch settings the KBox A 101 needs to be opened For opening and closing the KBox A 101 please perform the following steps Before opening the KBox A 101 the system must be switched off and disconnected from the main power supply Also disconnect peripheral devices from the KBox A 101 Before you begin ensure that you have a clean flat and ESD safe surface to work on
32. re ceci ve resize serie cei nenene 14 AR E A I 17 PARCO LEO RR EE 17 PZA PR ee 17 RR Wit E e teg RTRT A I II I TTT _VCT XIYYV Yp2 xc 220XxY7 ENEE 18 LABOU ON RR TI SI 19 7 5 DC Power Connection via Phoenix Connector ssssessssesessesessescsoescsossesossesossesossesesossesossesossesossesossesesoeeo 20 AD EE 20 6 SEATUING UD cccicasnnanresenasnanesauasteswecnatesscamsnnwsnaae dasa suantiaawsaseteesenases TATA RITIRATA RARI II ra 21 8 1 Connecting to DC Main Power Supply ER 21 8 1 1 Connecting the KBox A 101 to a DC Main Power Supp 21 8 2 Operating System and Hardware Component Drivers cscscsceccececececececececececececscececscseseseeeeseseceseseseceseeees 22 9 SetangUptneKBox CB 23 SL KBox A 101 Desktop Verio WEE 24 9 2 Wall or Table or Cabinet Mount using the Brackets cccececececscecscscsescscscseecececececscececececececseseeeaeeeeeeeseeeees 25 0 2 1 Brackets for Wall Table MOUN Gssincexconsdccvsessneasnasosnentcarsaarcntede dese E EEE E EEA E EA ENS 25 9 2 2 Bracket for El tt ne EE 27 9 2 3 DIN Rail OM e ipo 28 www kontron com 1 1 Table of Contents KBox A 101 User s Guide preliminary Version 1 00 9 3 Handling internal E GEES gereegelt deamaswenseanayoacoovesceseveaees 29 9 3 1 Opening and Closing the KBox A 101 rece eee eee eee eee 29 9 3 2 Configuration of the optional RS422 RS485 Bot 30 10 Maintenance and Prevention sisssesescsssicssenssicessassesacwse
33. rsion 1 00 5 Electromagnetic Compatibility Class A Device 5 1 Electromagnetic Compatibility EU This product is intended only for use in industrial areas The most recent version of the EMC guidelines EMC Directive 2004 108 EC and or the German EMC laws apply If the user modifies and or adds to the equipment e g installation of add on cards the prerequisites for the CE conformity declaration safety requirements may no longer apply Warning This is a class A product In domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 5 2 FCC Statement USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 5 3 EMC Compliance Canada The method of compliance is self declaration to Canadian standard ICES 003 English This Class A digital apparatus complies with the
34. s help to avoid electrostatic damages to the device 1 Cover workstations with approved antistatic material Always wear a wrist strap connected to workplace as well as properly grounded tools and equipment Use anti static mats heel straps or air ionizes to give added protection Always handle electrostatic sensitive components by their edge or by their casing Avoid contact with pins leads or circuitry Turn off power and input signals before inserting and removing connectors or connecting test equipment O oOo N Oh UI Keep work area free of non conductive materials such as ordinary plastic assembly aids and styrofoam 10 Use field service tools such as cutters screwdrivers and vacuum cleaners which are conductive 11 Always place drives and boards PCB assembly side down on the foam 4 2 Hot Surface Warning Please observe the warning label Hot Surface refer to Fig 7 and Fig 17 pos 3 in the area with cooling fins of the chassis The chassis of KBox A 101 gets hot during operation The marked surfaces with Hot surface labels should not be touched without appropriate precautions Risk of burns to the skin The material inside of the cabinet where the KBox A 101 system will be mounted must keep at least flammability class of UL 94 5VB Don t put flammable materials under the device www kontron com 7 5 Electromagnetic Compatibility Class A Device KBox A 101 User s Guide preliminary Ve
35. scensvawsucneeessvendensenscasuauoususwes esta deasbesesesesseuseessssassesuses 31 11 Techical Data E 32 11 2 1 KBox A 101 Desktop Dimensions e A 11 2 2 Dimension for Wall and Table MOUNTING e 3D 11 2 3 Dimensions for using the Bracket for Cabinet MOUNTING A 11 2 4 Dimension for KBox A 101 by using the DIN Rail Cp 39 11 4 CE Directives KEES 12 Standard Interfaces Pin Assignments seseseesesessecoscesesoecessesoscesescesesoesesoesesoesesecsesesoesesesseseesesesseseeses 43 12 12 Seral Interfaces COM1 and COM2 EECH 12 1 3 Serial Port RS422 RS485 configured as RS422 4 Channel Mode rece eee eee eee eee 44 12 1 4 Serial Port RS422 RS485 configured as RS485 4 Wire Mode Full Duplex Bus Master 44 12 1 5 Serial Port RS422 RS485 configured as RS485 2 Wire Mode Half Duplex 45 LINO 1217 DERISO POT lo e SSA I 46 FARINA I TCTe 0toeTme m o Te renx ee LEO o oo u_ _ e _C TT umw_w A 13 Techmcal SUPOTE osusrisssieririsevini tiiri cort trotn tanri E renne NOE E EEEE EN E EEEa 47 13 1 Returning Defective LETTRE 1 1 Table of Figures Fig 1 Front view with wall table mounting brackets esesesessssesesesesossssesesesossssesesosossssesesesesososessesesesosesseseee 9 Fig 2 Rear view with wall table mounting brackets sccscsscscsccecsccecscescscsscecnscecsseeceseeseceeceseeceseecsseeseceseeeess 9 EROS VE RR IE 10 POA R EE
36. struction with excellent mechanical stability of the KBox A 101 offer the superior qualities of a computer designed for operation in harsh industnal environment The KBox A 101 is a fanless system with a compact aluminum chassis with cooling fins The rated voltage of the mains can be found on the type label The type label is located at the bottom side of the device The KBox A 101 may be optionally factory equipped with a Mini PCIe WLAN card for two antennas For the configuration of your KBox A 101 please follow the ordering options specified in Configuration Guides KBox Series on our web site www kontron com Fig 4 Right side view Fig 6 Left side view Fig 8 Rear side view IS The device may be operated in all positions except with the top side facing down When switching on the KBox A 101 make sure that the air openings on the front side Fig 9 pos 3 and the rear side Fig 14 pos 2 and the cooling fins of the chassis are not obstructed covered by any objects To provide sufficient heat dissipation for the cooling of the device do not cover the cooling fins of the KBox A 101 Do not place any objects on the device When installing the platform please note the clearance recommendation in the section 11 2 Mechanical Specifications www kontron com 7 Product Description KBox A 101 User s Guide Version 1 00 7 1 Front Side USB 2 0 DISPLAY PORT ff PWR Fig 9 KBox A 1
37. tus If an error occurs the system will be turned off and the power LED will be blinking red Power LED System Status of Power off or failure of the Embedded Controller EC System held off i e over temperature etc System in S4 S5 System in S3 System in SO An over temperature condition has the highest of all priorities L As long as the temperature is too high the power LED blinks red and the power button is deactivated The HDD LED blinks when there is activity of the SATA HDD SSD or SATA drive HDD LED Storage Device Status Without SATA mSATA activity SATA mSATA activity 12 www kontron com 7 Product Description KBox A 101 User s Guide Version 1 00 7 1 3 External Interfaces of the SBC at the Front Side DISPLAY PORT Fig 11 External interfaces of the integrated SBC 1 DC Power Connector 4 2x USB 2 0 port 2 2xLAN port RJ45 10 100 1000Mbps 5 Serial port COM 1 configured as RS232 3 2x USB 3 0 port 6 Display Port Connector 7 1 3 1 LAN Ports ETH1 ETH2 These ports Fig 11 pos 2 consist of RJ45 connectors with integrated LEDs and support a transfer rate of 10 100 1000Mbps Link Status Link speed Link is established 100 Base T Link is established 1000 Base T 7 1 3 2 USB Ports The system is equipped with two USB 2 0 and two USB 3 0 interfaces Fig 9 pos 2 and Fig 11 pos 3 and 4 Various USB devices can be connected to these USB interface connectors 7 1
38. unk screws M3x8 IS014581 torx for the mounting of the internal HDD SSD drive Threaded holes for mounting the DIN rail mounting clip 6 Type label Do not loosen or remove the torx screws of the internal HDD SSD drive Fig 19 pos 3 JE If you intend to convert your device from the desktop version to a wall table mount version see also chapter 9 Setting Up the KBox A 101 www kontron com 7 Product Description KBox A 101 User s Guide preliminary Version 1 00 7 5 DC Power Connection via Phoenix Connector The KBox A 101 can be connected to a DC power source via a DC power cable only the Phoenix power plug terminal is included 7 5 1 DC Power Connector The KBox A 101 is delivered with a DC power plug terminal 3 pin Phoenix connector For DC connection prepare the connecting wires using the supplied Phoenix plug terminal IS The length of the DC connecting wires may not exceed 10 Fig 20 Phoenix power plug terminal with plus and minus marking 1 3 pin Phoenix plug terminal 4 Marking plus 2 Cover over the slotted pan head screws 5 Location for inserting the minus wire 3 Marking minus 6 Location for inserting the plus wire Cut the required length two isolated wires AWG18 up to 1 mm and strip each end 5 7 mm Twist the striped wire ends and tin it with solder Open the cover to have access to the slotted pan head screws e YY SL gt Loosen the t
39. wo slotted pan head screws that correspond to the marked location and of the DC plug terminal far enough so that you can insert the end of the prepared wires 5 Insert the wires into the corresponding clamp of the Phoenix plug terminal Make sure that you have the right polarity of the connection refer to Fig 20 6 Fasten the screws to secure the wires into the clamps of the plug terminal 7 Close the cover IS The second end of each wire will be prepared as required for the connection to the DC power supply www kontron com 8 Starting Up KBox A 101 User s Guide Version 1 00 8 Starting Up IS The rated voltage of the power supply must agree with the voltage value on the type label 8 1 Connecting to DC Main Power Supply The DC input connector Fig 9 pos 1 is located on the front side of the KBox A 101 The KBox A 101 can be connected to a DC main power supply see Fig 21 via a DC power cable and the supplied Phoenix power plug terminal see Fig 20 Even when the system is turned off via the power button Fig 10 pos 1 there is still a standby voltage of 5 VSb on the SBC The DC main power supply must be able to be switched off and on via a 2 pole disconnecting device which must always remain easily accessible The DC input must fulfill SELV Safety Extra Low Voltage requirements of EN60950 1 standard 8 1 1 Connecting the KBox A 101 to a DC Main Power Supply KBox A 10