1. Supports 24 ports 100Base TX and 2 1000BaseT with 2 shared Mini GBIC User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports IEEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput Up to 8 8 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides non blocking switching performance Provides a RS 232 port for system configuration 11 8 Port 100BaseTX 2 Gigabit Combo L2 Management Switch Support 8 ports 100BaseTX and 2 ports1000BaseT with 2 shared Mini GBIC 100FX amp 1000SX LX mini GBIC fiber module on mini GBIC ports Supports half duplex and full duplex modes and auto negotiation for all copper ports Auto MDI MDI X on all twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Support 8K L2 MAC address entries and 256KB packet memory 128Kb control memory m Operation through put supports up
2. User Guide Layer 2 Management Switch 1 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch 2 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch 6 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget 7 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 100W PoE power budget 8 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch 9 24 Port 100BaseTX 2 Gigabit Combo Layer 2 Management Switch with 12 PSE port embedded 180W PoE power budget 10 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Desktop 11 8 Port 100BaseTX 2 Gigabit Combo L2 Management Switch The information in this guide may be changed without notice The manufacturer assumes no responsibility for any errors which may appear in this guide Ethernet is a trademark of XEROX Corporation Microsoft Windows and Windows logo are trademarks of Microsoft Corporation Copyright 2008 All right are reserved No Part of the contents of this guide maybe transmitted or reproduced in any form or by any means without the written permission of us Printed in Taiwan The revision date for this gui
3. 40 C 82 F 104 F Storage Temp 40 C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 8 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch Size H x W x D H44 45 x W260 x D170 mm Weight Net Gross 1 3kg 2 0kg 450z 700z Power 12VDC 1 0A Operating Temp 0 C 40 C 82 F 104 F Storage Temp 40 C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 9 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 180W PoE power budget Size H x W x D H 44 x W 430 x D 350mm Weight Net Gross 4 1kg 5 1kg 145 oz 180 oz Power 100 120 200 240 VAC 3 0 A 1 5 A 50 60Hz Operating Temp 0 C 40 C 82 F 104 F Storage Temp 40 C 70 C 40 F 158 F Layer 2 2 Management Switch Series 83 Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 10 24 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch Desktop Size H x W x D H44 45 x W260 x D170 mm Weight Net Gross 1 3kg 2 0kg 450z 700z Power 12VDC 1 5A Operating Temp 0 C 40
4. Enable disable storm control Format storm control enable disable Mode Interface Config 2 storm control broadcast This command storm control for broadcast only and limited value 0 64 256 1024 10240 65536 102400 1024000 which the unit is Kbps and 0 means no limit Format storm control broadcast lt rate gt Mode Interface Config 3 storm control broadcast multicast This command storm control limited Layer 2 2 Management Switch Series 57 value 0 64 256 1024 10240 65536 102400 1024000 which the unit is Kops and 0 means no limit Format storm control broadcast multicast lt rate gt Mode Interface Config 4 storm control broadcast unknown This command storm control limited value 0 64 256 1024 10240 65536 102400 1024000 which the unit is Kops and 0 means no limit Format storm control broadcast unknown lt rate gt Mode Interface Config e g Switch Interface 1 storm control broadcast unknown 64 5 storm control all cast This command storm control limited value 0 64 256 1024 10240 65536 102400 1024000 which the unit is Kops and 0 means no limit Format storm control all cast lt rate gt Mode Interface Config rmon counter This command specifies rmon counter capability on a port Format rmon counter enable disable Mode Interface Config set igmp router port This command specifies a igmp router port Format set igmp router port enable disable Mode Interface Config spanning tree 1 spanni
5. Format gvrp enable Mode Global Config 2 gvrp disable This command is used to disable gvrp function globally Format gvrp disable Mode Global Config 3 gvrp port_enable This command is used to enable gvrp function on a specified port Format gvrp port_enable lt port id gt Mode Global Config 4 gvrp port_disable This command is used to disable gvrp function on a specified port Format gvrp port_disable lt port id gt Mode Global Config 5 gvrp port_status lt port list gt This command is used to displays the gvrp port information Format gvrp port_status lt port list gt Mode Global Config https This command is used to set https enable or disable Format https enable disable Mode Global Config BOOTP 1 bootp enable This command is used to enable bootp function Format bootp enable Mode Global Config 2 bootp disable This command is used to disable bootp function Layer 2 2 Management Switch Series 53 Format bootp disable Mode Global Config 3 bootp renew This command is used to renew bootp Format bootp renew Mode Global Config SSH 1 ssh enable This command is used to enable ssh function Format ssh enable Mode Global Config 2 ssh disable This command is used to disable ssh function Format ssh disable Mode Global Config 3 ssh changekey This command is used to change key function Format ssh changekey Mode Global Config lpsrcgd Note This feature only supports on the following switches 4 24 Port
6. Format show snmp users Mode Privileged Mode 3 show snmp communities This command displays all snmp communities Format show snmp communities Mode Privileged Mode 4 show snmp info This command displays all snmp information Format show snmp info Mode Privileged Mode 15 show sntp This command is used to displays switch sntp information Format show snip Mode Privileged Mode 16 show spanning tree This command displayss Spanning Tree information 16 1 show spanning tree interface This command displays RSTP ports information 16 1 1 show spanning tree interface port This command specify an switch interface Format show spanning tree interface port lt port D gt Mode Privileged Mode 16 1 2 show spanning tree interface all This command displays all switch interface Format show spanning tree interface all Mode Privileged Mode 16 2 show spanning tree mst This command displays MST information 16 2 1 show spanning tree mst detailed This command displays a MST instance information Format show spanning tree mst detailed lt 0 4094 gt Mode Privileged Mode 16 2 2 show spanning tree mst instance This command displays ports information on a MST instance Format show spanning tree mst instance lt 0 4094 gt Mode Privileged Mode Layer 2 2 Management Switch Series 28 16 2 3 show spanning tree mst summary This command displays all MST instance information Format show spanning tree mst summary Mode Privileged Mode 1
7. clear L4port 3 3 1 access list name lt WORD gt clear L4port SRC port This command clears TCP UDP source port filter Layer 2 2 Management Switch Series 47 Format access list name lt WORD gt clear l4port SRC port Mode Global Config 3 3 2 access list name lt WORD gt clear l4port DST port This command clears TCP UDP destination port filter Format access list name lt WORD gt clear l4port DST port Mode Global Config 3 4 access list name lt WORD gt clear packet type This command clears packet type filter Format access list name lt WORD gt clear packet type Mode Global Config 3 5 access list name lt WORD gt clear mac SA This command clears a source mac address Format Access list name lt WORD gt clear mac SA Mode Global Config 3 6 access list name lt WORD gt clear MAC DA This command clears a destination mac address Format Access list name lt WORD gt clear mac DA Mode Global Config 3 7 access list name lt WORD gt clear VID This command clears the 802 1Q VLAN tag of packet Format Access list name lt WORD gt clear VID Mode Global Config 3 8 access list name lt WORD gt clear ether type This command clears ether type filter Format access list name lt WORD gt clear ether type Mode Global Config 4 access list name lt WORD gt deletes This command removes the ACL entry Format access list name lt WORD gt deletes Mode Global Config 5 access list name lt WORD gt enable disabl
8. 1 static address add This command is used to add static mac address Format static address add lt mac addr gt vid lt vlan ID gt port lt port ID gt Mode Global Config 2 static address delete This command is used to delete static mac address Format _static address delete lt mac addr gt vid lt vlan D gt Mode Global Config mgmt accesslist 1 mgmt accesslist ipaddr This command specifies a management access IP for the DUT up to 8 IP address can be set Format mgmt accesslist ipaddr lt P addr gt Mode Global Config 2 mgmt accesslist enable This command enables management access list Only the IP address specified in the management list is allowed to access DUT Format mgmt accesslist enable Mode Global Config 3 mgmt accesslist disable This command disables management access list Format mgmt accesslist disable Mode Global Config monitor Layer 2 2 Management Switch Series 36 1 monitor enable This command enables port mirroring Format monitor enable Mode Global Config 2 monitor disable This command disables port mirroring Format monitor disable Mode Global Config 3 monitor des Configure destination port 3 1 monitor des lt port ID gt probetype bidirection This command configures port monitor probetype as bi direction traffic Format monitor des lt port D gt probetype bidirection src lt port list gt Mode Global Config e g Switch config monitor des 1 probetype bidirection src
9. 2 8 3 2 monitor des lt port ID gt probetype ingress This command configures port monitor probetype as ingress traffic Format monitor des lt port D gt probetype ingress src lt port list Mode Global Config e g Switch config monitor des 1 probetype ingress src 2 8 3 3 monitor des lt port ID gt probetype egress This command configures port monitor probetype as egress traffic Format monitor des lt port D gt probetype egress src lt port list Mode Global Config e g Switch config monitor des 1 probetype egress src 2 8 dot1x 1 dotix enable This command enables global 802 1x function Format dot1x enable Mode Global Config 2 dotix disable This command disables global 802 1x function Format dot1x disable Mode Global Config 3 dot1x port control Configure port auto authentication mode 3 1 dot1x port control enable This command set auto authorized on a list of ports Format dot1x port control enable port lt port list gt Mode Global Config 3 2 dot1x port control disable This command set force authorized on a list of ports Format dot1x port control disable port lt port list Mode Global Config e g Switch config dot1x port control disable port 1 4 network 1 network mgmt vlan This command changes management vlan Format network mgmt vlan lt vian D gt Layer 2 2 Management Switch Series 37 Mode Global Config 2 network parms This command configures static IP address of the switch Format
10. 2 Gigabit combo Layer 2 Management Switch 3 _48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch POWER Green LED lights up it shows the system is powered up LINK ACT Green LED lights up it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data 1000Mbps Amber LED lights up only when the corresponding port works at 1000Mbps 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch PWR Green LED lights up it shows the system is powered up Port LED lights up as Green it indicates a successful connection of that port is established at 10 100 Mbps If lights up as Amber it indicates a 1000 Mbps connection Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data Layer 2 2 Management Switch Series 13 6 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget PWR Green LED lights up it shows the system is powered up Link Act Green LED lights up it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When
11. 2 dhcpsnooping static delete This command is used to delete a static dhcp entry Format dhcpsnooping static delete ip lt A B C D gt mac lt mac address gt port lt port id gt vid lt vlan id gt Mode Global Config 8 dhcpsnooping dyamic This command is used to configure dhcp dynamic entry 8 1 dhcpsnooping dynamic add This command is used to add a dynamic dhcp entry Format dhcpsnooping dynamic add ip lt A B C D gt mac lt mac address gt port lt port id gt vid lt vlan id gt lease time lt 1 9999999 gt Mode Global Config 8 2 dhcpsnooping dynamic delete This command is used to delete a dynamic dhcp entry Format dhcpsnooping dynamic delete ip lt A B C D gt mac lt mac address gt port lt port id gt vid lt vlan id gt lease time lt 1 9999999 gt Mode Global Config Layer 2 2 Management Switch Series 52 Loop_detect 1 Loop_ detect enable This command is used to enable port self loop detection Format loop detect enable Mode Global Config 2 loop_detect disable This command is used to disable port self loop detection Format loop detect disable Mode Global Config 3 loop_detect recovertime This command is used to set the recover time Format loop_detect recovertime lt 0 65535 gt Mode Global Config 4 loop detect trytorecover This command is used to try to recover all the selfloop port immediately Format loop detect trytorecover Mode Global Config GVRP 1 gvrp enable This command is used to enable gvrp function globally
12. C 82 F 104 F Storage Temp 40 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 11 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch Size H x W x D H44 45 x W260 x D170 mm Weight Net Gross 1 3kg 2 0kg 450z 700z Power 12VDC 1 0A Operating Temp 0 C 40 C 82 F 104 F Storage Temp 40 C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 4 4 Standard Conformance EMC Certification FCC Class A CE Layer 2 2 Management Switch Series 84 5 Warranty statement We provide this limited warranty for it originally purchased the product from us or its authorized reseller or distributor We guarantee that equipment is free from physical defects in workmanship and material under normal use from the date of original retail purchase of the Hardware If the product proves defective during this warranty period call our Customer Service in order to obtain a Return Authorization number Be sure to have a proof of purchase on hand when calling Return requests cannot be processed without proof of purchase When returning a product mark the Return Authorization Number clearly on the package pack and include you ori
13. Global Config arp Note This commands only support on 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch models 1 arp dynamic 1 1 arp dynamic enables and disables This command enables and disables dynamic arp functions Layer 2 2 Management Switch Series 49 Format arp dynamic enable disable Mode Global Config 1 2 arp dynamic aging time This command set arp dynamic aging time between Os and 999s 0 means disable Format arp dynamic aging time lt 0 999 gt Mode Global Config 1 3 arp dynamic ports This command set dynamic arp ports to trust and un trust Format arp dynamic ports trust untrust lt port list gt Mode Global Config e g Swtich lt Config gt arp dynamic ports trust 1 4 Swtich lt Config gt arp dynamic ports untrust 4 1 4 arp dynamic vian This command set add remove dynamic arp on specified vlan Format arp dynamic vlan add remove from lt vlan id gt to lt vlan id gt Mode Global Config e g Swtich lt Config gt arp dynamic vian add from 1 to 1 Swtich lt Config gt arp dynamic vlan remove from 1 to 1 2 arp static command This command set arp static address table for mac address with IP Address Format arp static add delete vid lt 1 4094 gt ip lt A B C D gt mac lt mac address gt Mode Global Config dos Note This command only supports on the following switches 3 48 Port 100BaseTX 4 1000Ba
14. Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 9 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 180W PoE power budget Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View Supports IGMP snooping to limit flooding of IP multicast traffic and filtering for controlling the set of multicast groups to which hosts on a switch port can belong m Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Supports IEEE 802 3ad Link Aggregation up to 6 LAG groups and 8 ports for each LAG group Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports many to one one to one Port Mirroring function Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high
15. activating and transmitting data Amber LED lights up only when the corresponding port works at 1000Mbps 2 4Reset Button There is a Reset button on the front panel which has two functionalities a To restore switch configuration to factory defaults Press the Reset button for more than 10 seconds switch configuration will be restored to factory defaults and then reboots b To reboot switch Press the Reset button for less than 10 seconds switch will reboot Please note you will lose unsaved change when doing this 2 5Installing the Switch This section describes how to install and make connection to your Managed Switch The following diagrams shows the a typical network configuration Figure 2 5 1 shows the network configuration for L2 L2 Management Switch Figure 2 5 2 shows the network configuration for L2 L2 Management Switch with PoE function Figure 2 5 1 Network Configuration for L2 L2 Management Switch Cable DSL Internet Modem BAe nT e 3 we gee Pe Menage Sas rere Desktop Notebook Server Layer 2 2 Management Switch Series 15 Figure 2 5 2 Network Configuration for L2 Management Switch with PoE Cable DSL Router Internet Modem Powered Device Desktop Wireless Access Point Notebook Server Powered Device Read and perform the following procedures to install the switch Pre Installation Considerations Gigabit Considerations If you will use the switch for Gigabit appli
16. command configures RSTP bridge priority value Format spanning tree priority lt 0 61440 gt Mode Global Config 8 spanning tree mst Configure a multiple spanning tree instance 8 1 spanning tree mst instance This command creates or removes a MST instance Layer 2 2 Management Switch Series 45 8 1 1 spanning tree mst instance add This command creates a MST instance Format spanning tree mst instance add vlan lt vian list gt mstpid lt MST ID gt Mode Global Config e g Switch Config Spanning Tree mst instance add vlan 2 5 mstpid 2 Switch Config Spanning Tree mst instance add vlan 6 mstpid 3 8 1 2 spanning tree mst instance delete This command removes the last MST instance Format spanning tree mst instance delete Mode Global Config 8 2 spanning tree mst vlan This command adds or deletes vlan frome a MSTP instance 8 2 1 spanning tree mst vlan lt MST ID gt lt vlan list gt add This command creates a MST instance Format spanning tree mst vlan lt MST ID gt lt vian list gt add Mode Global Config e g Switch Config Spanning Tree mst vlan 3 3 5 add 8 2 2 Spanning Tree mst vlan lt MST ID gt lt vlan list gt delete This command deletes a vlan from a MST instance Format Spanning Tree mst vlan lt MST ID gt lt vlan list delete Mode Global Config 8 3 spanning tree mst bridgepri This command configures bridge priority for a MST instance Format spanning tree mst bridgepri lt MST ID gt lt priority
17. configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports IEEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput Up to 8 8 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides non blocking switching performance Provides a RS 232 port for system configuration Total Power Budget 100 W with 8 W guard band It means system can provide total 92 W power to power devices Supports 30 W high power devices Layer 2 2 Management Switch Series 78 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch Supports 8 ports 100Base TX and 2 1000BaseT with 2 shared Mini GBIC User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports IEEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput Up to 5 6 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up
18. groups to which hosts on a switch port can belong Layer 2 2 Management Switch Series 62 Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports many to one Port Mirroring Supports IEEE 802 3ad Link Aggregation up to 3 aggregation groups 4 ports for each group Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high priority voice traffic on a port port basis Per port ingress and egress rate limiting minimum rate is 64 Kbps granularity is 64 Kops Supports Static Mode and Dynamic Learning Mode for Port Security function Support up to 24 MAC addresses for each port Supports Protected port feature Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast known multicast and unknown unicast storm control Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Su
19. gt Mode Global Config 1 6 set igmp query resinterval This command specifies igmp query response interval lt secs gt Format set igmp query resinterval lt 0 200 gt Mode Global Config Layer 2 2 Management Switch Series 41 1 7 set igmp robustness This command specifies robustness variable Format set igmp robustness lt 1 20 gt Mode Global Config 1 8 set igmp router port This command specifies igmp router port Format set igmp router port ports lt port list Mode Global Config e g Switch config set igmp router port ports 1 10 2 set igmp querier This command configures igmp querier Format set igmp querier enable disable Mode Global Config 3 set igmp proxy This command configures igmp proxy Format set igmp proxy enable disable Mode Global Config 4 set static mcast Configure static multicast 4 1 set static mcast name lt WORD gt add This command create a multicast group Format set static mcast name lt WORD gt add vid lt vlan ID gt mac lt mac adadr gt member port lt port list gt Mode Global Config 4 2 set static mcast name lt WORD gt delete This command delete a static multicast group Format set static mcast name lt WORD gt delete Mode Global Config snmp 1 snmp notify This command configures snmp notification Format snmp notify enable disable Mode Global Config 2 snmp group 2 1 snmp group add This command create a snmp group Format snmp group add lt WORD gt v
20. gt Mode Global Config 8 4 spanning tree mst cost This command configures port path cost in a MST instance Format spanning tree mst cost lt MST ID gt lt path cost ports lt port list Mode Global Config 8 5 spanning tree mst priority This command configures port priority ina MST instance Format spanning tree mst priority lt MST ID gt lt priority gt ports lt port list gt Mode Global Config User This command changes user password Format user password Mode Global Config Interface This command enters into configure interface mode Format Interface lt port D gt Mode Global Config rmon This command is used to configure RMON 1 rmon event This command creates rmon event entry Format rmon event index lt 7 65535 gt desc lt WORD gt event lt 1 4 gt community lt WORD gt owner lt WORD gt Mode Global Config Layer 2 2 Management Switch Series 46 e g Switch Config rmon event index 1 desc 123 event 4 community 123 owner test 2 rmon alarm This command creates rmon alarm entry Format rmon alarm index lt 1 65535 gt interval lt 0 3600 gt interface lt port number gt counter lt 1 17 gt sample absolute delta start rasing falling all rthreshol d lt 0 65535 gt fthreshold lt 0 65535 gt reindex lt 0 65535 gt feindex lt 0 65535 gt owner lt WORD gt Mode Global Config e g Switch Config RMON alarm index 1 interval 10 interface counter 1 sample delta start all rthreshold 100 fthreshol
21. is used to displays class of service information 1 4 1 show qos port based port This command displays class of service information Format show qos port based port lt port D gt Mode Privileged Mode 1 4 2 show qos port based all This command displays all switch interfaces cos settings Format show qos port based all Mode Privileged Mode 2 show dot1x Layer 2 2 Management Switch Series 25 This command displays dot1x information 2 1 show dot1x config This command displays dot1x and port configuration Format show dot1x config Mode Privileged Mode 2 2 show dot1x radius This command displays radius configuration Format show dot1x radius Mode Privileged Mode 2 3 show dot1x statistics This command displays dot1x statistics Format show dot1x statistics Mode Privileged Mode 3 show igmpsnooping This command displays IGMP snooping information 3 1 show igmpsnooping dynamic_router_port This command displays dynamic router ports information Format show gmpsnooping dynamic_router_port Mode Privileged Mode 3 2 show igmpsnooping groups This command is used to displays gmp groups information Format show igmpsnooping groups Mode Privileged Mode 3 3 show igmpsnooping info This command displays IGMP Snooping configuration information Format show igmpsnooping info Mode Privileged Mode 5 show lag This command is used to displays link aggregation groups information 5 1 show lag lag index This command is used to
22. network parms lt P addr gt lt subnet mask gt lt gateway gt Mode Global Config 3 network protocol This command configure switch dhcp client Format network protocol dhcp none Mode Global Config 4 network dhcp relay Configure switch dhcp relay functions 4 1 network dhcp relay mode This command configures dhcp relay mode Format network dhcp relay mode enable disable Mode Global Config 4 2 network dhcp relay server This command configures dhcp relay server ip address Format network dhcp relay server lt A B C D gt Mode Global Config 4 3 network dhcp relay vlan Configure dhcp relay option 82 vlan information 3 1 network dhcp relay vlan lt vlan ID gt add This command enters a vlan which will be enable DHCP relay option82 Format network dhcp relay vlan lt vlan ID gt add Mode Global Config 3 2 network dhcp relay vlan lt vlan ID gt remove This command enters a vlan which will be disable dhcp relay option82 Format network dhcp relay vlan lt vian D gt remove Mode Global Config 5 network sysinfo Configure switch system information 5 1 Network sysinfo sysname This command configures system name Format network sysinfo sysname lt WORD gt Mode Global Config 5 2 network sysinfo syslocate This command configures system location Format network sysinfo syslocate lt WORD gt Mode Global Config 5 3 network sysinfo syscontact This command configures system contact information Format ne
23. port index This command is used to specify an switch interface Format show port port index lt port D gt Mode Privileged Mode 10 2 show port all This command is used to displays all switch interface Format show port all Mode Privileged Mode 11 show port security This command is used to displays port security settings 11 1 show port security port This command is used to specify an switch interface Format show port security port lt port D gt Mode Privileged Mode 11 2 show port security all This command is used to displays all interfaces status Format show port security all Mode Privileged Mode 12 show rate limit This command is used to displays ingress and egress rate limit information 12 1 show rate limit port This command is used to specify an switch interface Format show rate limit port lt port D gt Mode Privileged Mode e g Switch Show rate limit port 1 Switch Show rate limit port g1 12 2 show rate limit all Layer 2 2 Management Switch Series 27 This command is used to displays all interfaces status Format show rate limit all Mode Privileged Mode 13 show running config This command is used to displays switch running config Format show running config Mode Privileged Mode 14 show snmp This command is used to displays all snmp config 14 1 show snmp groups This command displays all snmp groups Format show snmp groups Mode Privileged Mode 14 2 show snmp users This command displays all snmp users
24. ports 5 1 port all rate limit egress This command specifies egress rate limit Format port all Rate Limit egress lt value gt Mode Global Config 5 2 port all rate limit ingress This command specifies ingress rate limit Format _ port all rate limit ingress lt value gt Mode Global Config 6 port all rmon counter This command configures rmon counter capability on ports Format port all rmon counter enable disable Mode Global Config 7 port all speed This command configures ports speed Format port all speed 1 0hd 10fd 100hd 100fd Mode Global Config 8 port all storm control Configure all ports storm control settings 8 1 port all storm control disable This command disables storm control Format port all Storm Control disable Layer 2 2 Management Switch Series 39 Mode Global Config 8 2 port all storm control broadcast This command configures storm control for broadcast only Format port all storm control broadcast lt value gt Mode Global Config 8 3 port all storm control broadcast multicast This command configures storm control for broadcast and multicast Format port all Storm Control broadcast multicast lt value gt Mode Global Config 8 4 port all storm control broadcast unknown This command configures storm control for broadcast and unknown unicast Format port all storm control broadcast unknown lt value gt Mode Global Config 8 5 port all storm control all cast This command configur
25. protected enable disable Mode Global Config 4 2 3 vlan port ports pvid This command is used to configure port vid Format vlan port ports pvid lt vian D gt Mode Global Config 5 vlan lag This command is used to configure lag to a special vlan 5 1 vlan lag vlan lt vlan id gt exclude This command is used to remove lag from a vlan Format vlan lag vlan lt vian D gt exclude lags lt lag ID gt Mode Global Config 5 2 vlan lag vlan lt vlan ID gt untagged This command is used to set to untagged lag Format vlan lag vlan lt vlan ID gt untagged lags lt lag ID gt Mode Global Config 5 3 vlan lag vlan lt vlan ID gt tagged This command is used to set to tagged lag Format vlan lag vlan lt vlan ID gt tagged lags lt lag ID gt Mode Global Config bridge This command is used to configure switch aging time Format bridge aging time lt 0 1048575 gt Mode Global Config lacp syspri This command is used to configure lacp system priority Format lacp syspri system priority lt 0 65535 gt Mode Global Config link aggregation This command is used to configure link aggregation 1 link aggregation addport This command is used to configure LAG groups Format Link Aggregation addport lag lt LAG ID gt Mode Global Config 2 link aggregation delport This command remove ports from LAG 2 1 Link Aggregation delport all This command remove all ports from a LAG Format link aggregation delport all lag lt LAG ID gt Mo
26. specify an switch lag Format show lag lag index lt ag id gt Mode Privileged Mode 5 2 show lag all This command is used to displays all switch lags Format show lag all lt ag ia gt Mode Privileged Mode 6 show Ildp This command is use to displays Ildp statistics 6 1 show Ildp statistic This command is used to displays Ildp statistic Format show lidp statistic Mode Privileged Mode 6 2 show Ildp local This command is used to displays local information Format show lldp local Mode Privileged Mode 6 3 show Ildp msap This command is used to displays msap information Format show Ildp msap Mode Privileged Mode Layer 2 2 Management Switch Series 26 6 4 show Ildp msap entry This command is used to displays msap details information Format show lldp msap entry lt 7 26 gt Mode Privileged Mode 7 show logging This command is used to displays trap records 7 1 show logging memory log This command displays memory log Format show logging memory log Mode Privileged Mode 7 2 show logging flash log This command displays flash logs Format show logging flash log Mode Privileged Mode 8 show monitor This command is used to displays port mirroring settings Format show monitor Mode Privileged Mode 9 show network This command is used to configuration for inband connectivity Format show network Mode Privileged Mode 10 show port This command is used to displays port mode and settings displays port status 10 1 show port _
27. standard wall outlet 2 6 Rack Mount Placement Before mounting the Switch please read the following instructions carefully A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern E Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips To mount the Switch in any standard sized 19 inch wide 1U high rack please follow these instructions Place the S
28. the LED blinks it indicates the port is activating and transmitting data PoE Amber LED lights up only when the corresponding port supply power 7 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 port embedded 100W PoE power budget PWR Green LED lights up it shows the system is powered up Link Act Green LED lights up it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data PoE Amber LED lights up only when the corresponding port supply power 100M Amber LED lights up it indicates the non PoE ports have a 100Mbps connection Otherwise it indicates the link is 10Mbps or off or no link 8 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch PWR Green LED lights up it shows the system is powered up Link Act Green LED lights up it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data 1000M Amber LED lights up only when the corresponding port works at 1000Mbps 9 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 port embedded 180W PoE power budget PWR Green LED lights up it shows the system is powered up Link Act Green LED lights u
29. the User To exit to the User Mode 9 Mode enter the Switch Mode enter exit or enable command Logout From the Privileged To exit to the Global Mode enter the Privileged Mode Config Mode configuration Switch tooniga enter the exit command command From the Global s Interface Config mode enter To exit to the Global Switch Interface lt port gt Config mode enter Config Mode the interface exit lt port gt command The CLI is divided into various modes The commands in one mode are not available until the operator switches to that particular mode The commands available to the operator at any point in time depend upon the mode Entering a question mark at the CLI prompt and displayss a list of the available commands and descriptions of the commands The CLI provides the following modes User Mode When the operator logs into the CLI the User Mode is the initial mode The User Mode contains a limited set of commands The command prompt shown at this level is Command Prompt COMMAND gt Privileged Mode To have access to the full suite of commands the operator must enter the Privileged Mode The Privileged Mode requires password authentication From Privileged Mode the operator can issue any Exec command to enter the Global Configuration mode The command prompt shown at this level is Command Prompt Switch Global Config Mode This mode permits the operator to make modifications to
30. the running configuration General setup commands are grouped in this mode From the Global Configuration mode the operator can enter the Interface Configuration mode The command prompt at this level is Command Prompt Switch Config From the Global Config mode the operator may enter the following configuration modes Interface Config Mode Layer 2 2 Management Switch Series 21 Many features are enabled for a particular interface The Interface commands enable or modify the operation of an interface In this mode a physical port is set up for a specific logical connection operation The command prompt at this level is Command Prompt Switch Interface lt port gt 3 3 1 User Mode commands help This command displays help information Format help Mode User Mode This command displays help information Format help Mode User Mode logout This command is used to exit from the telnet Format logout Mode User Mode ping This command sends echo messages Format ping lt A B C D gt Mode User Mode show 1 show port This command displays port status Format show port lt port gt all Mode User Mode 2 show network This command displays switch IP configuration Format show network Mode User Mode 3 show system This command displays system information Format show system Mode User Mode 4 show port statistics This command displays port statistics Format show port statistics lt port all
31. to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides non blocking switching performance Provides a RS 232 port for system configuration Layer 2 2 Management Switch Series 79 9 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 180W PoE power budget Supports 24 ports 100Base TX with 12 ports PoE PSE and 2 1000BaseT with 2 shared Mini GBIC User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports EEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput Up to 8 8 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides non blocking switching performance Provides a RS 232 port for system configuration Flexible TCAM based Compact Field Process for packet classification and filtering Total Power Budget 180 W with 8 W guard band It means system can provide total 172 W power to power devices Supports 30 W high power devices Layer 2 2 Management Switch Series 80 10 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Desktop
32. 0BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch Standard models equipped with 48 RJ 45 ports for 10 100BASE TX connections and four RJ 45 ports for 10 100 1000BASE T with 2 shared Mini GBIC slots for further extension User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports Supports half duplex and full duplex modes and auto negotiation for all FE amp GE ports MDI MDI X auto sense on all ports and IEEE 802 3ab Auto MDI MDI X on all 100 1000 twisted pair ports Provides per port flow control and backpressure Supports 8K MAC addresses Supports 4K entry multicast address table Supports 4 Mbit total packet buffer and control memory Provides Store and Forward switching mechanism m Provides non blocking switching performance Provides a RS 232 port for system configuration Flexible TCAM based Compact Field Process for packet classification and filtering Layer 2 2 Management Switch Series 74 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch Support 24 10 100 1000 Mbps copper ports with 2 shared mini GBIC slots User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports Supports half duplex and full duplex modes and auto negotiation for all 10BASE T 100BASE TX 1000BASE T ports IEEE 802 3ab Auto MDI MDI X on all 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic ad
33. 1 You can also refer to the illustrations and charts of the internal wiring on the following page There are two types of cables Straight Through Cables and Crossover Cables Category 5 UTP STP cable has eight wires inside the sheath The wires form four pairs Straight Through Cables has same pinouts at both ends while Crossover Cables has a different pin arrangement at each end Layer 2 2 Management Switch Series 61 Figure 4 1 shows the diagram of Straight Through Cables Figure 4 2 shows the diagram of Crossover Cables Figure4 1 Diagram of Straight Through Cables Pins 4 5 7 and amp are not used Becomes Hd T ONS 1 gt 1 at yp 2 2 atone 3 3 6 6 Figure4 2 Diagram of Crossover Cables Diagram Pins 4 6 7 and 8 are not used Ss Ee Pin 1 gt Orange White Pin 2 gt Orange Pin 3 gt Green White Pin 6 gt Green Pin gt BrownWhite Pin 8 gt Brown lII 4 2 Technical Specification 4 2 1 Software Specification 1 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View IGMP snooping support to limit flooding of IP multicast traffic and filtering for controlling the set of multicast
34. 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch 1 ipsrcgd enable This command is used to enable ip source guard function Format ipsrcgd enable Mode Global Config 2 ipsrcgd disable This command is used to disable ip source guard function Format ipsrcgd disable Mode Global Config 3 ipsrcgd ports This command is used to configure ports to enable or disable ip source guard Format ipsrcgd ports enable disable Mode Global Config 4 ipsrcgd retry This command is used to configure the retry mechanism of ip source guard database 4 1 ipsrcgd retry now This command is used to retry inactive entries now Format ipsrcgd retry now Mode Global Config 4 2 ipsrcgd retry interval This command is used to retry inactive entries after a interval Format ipsrcgd retry interval lt 0 1440 gt Mode Global Config Layer 2 2 Management Switch Series 54 3 3 1 Interface Config mode commands exit Exit current shell Format exit Mode Interface Config dot1x Set 802 1x port control Set auto authorized or force authorized on ports Format 802 1x port control enable disable Mode Interface Config lacp 1 admin command Configure admin key of port Format lacp admin lt 0 65535 gt Mode Interface Config e g switch interface g1 lacp admin 36768 2 priority command Configure lacp port priority Format _ lacp priority lt 0 65535 gt Mod
35. 2 management switches which supports 802 1Q VLAN QoS 802 1d 1w 1s Spanning Tree Protocol 802 1x Port Security Port Mirroring IGMP Snooping SNTP Storm Control Rate Control SNMP etc features 2 2 Switch Front and Rear Panel 2 2 1 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch The front panel of 24 Port 100BaseTX 2 Gigabit combo ports Layer 2 Management Switch has 24 10 100 Mbps copper ports at the left 2 10 100 1000 Mbps copper ports and 2 Gigabit SFP slots at the right The product name indicates at the top on the left Figure 2 2 1a shows a front panel of this switch The rear panel has a power connector and figure 2 2 1b shows a rear panel of the switch Table 2 2 1c shows the port function of the switch Figure 2 2 1a Front Panel Scene ame os on oe oa in a a is a E _a Bsesssseresrslz s TEPE TEPE TEPE a F g o a Figure 2 2 1b Rear Panel Table 2 2 1c Port Function Port Function 1 24 This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2 ethernet cable for 10 100 1000 Mbps ethernet connection miniGBIC This is where you connect the SFP module for fiber connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the AC power cord Layer 2 2 Management Switch Series 5 2 2 2 24 Port 100Ba
36. 6 2 4 show spanning tree status This command is used to displays spanning tree status Format show Spanning tree status Mode Privileged Mode 17 show storm control This command is used to displays storm control information Format show storm control Mode Privileged Mode 18 show sysinfo This command is used to displays system information including system up time Format show sysinfo Mode Privileged Mode 19 show switch This command is used to displays switch information 19 1 show switch admin time This command displays the age time of web and console Format show switch admin time Mode Privileged Mode 19 2 show switch age time This command displays the age time of L2 table Format show switch age time Mode Privileged Mode 19 3 show switch mac table This command is used to displays address resolution protocol cache 19 3 1 show switch mac table all This command displays all element of the mac table Format show switch mac table all Mode Privileged Mode 19 3 2 show switch mac table vian This command displays all mac in a specify vlan Format show switch mac table vlan lt vlan id gt Mode Privileged Mode 19 3 3 show switch mac table port This command displays all mac in a specify port Format show switch mac table port lt port id gt Mode Privileged Mode 19 4 show switch mcast table This command displays multicast address table Format show switch mcast table Mode Privileged Mode 19 5 show switch mac This command displays vlan and port inf
37. C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch Size H x W x D H 44 45 x W 430 x D 350mm Weight Net Gross 4 7kg 5 8kg 165 oz 204 oz Power 100 120 200 240 VAC 1 5 A 0 75 A 50 60Hz Operating Temp 0 C 40 C 82 F 104 F Storage Temp 40 C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing Layer 2 2 Management Switch Series 82 6 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget Size H x W x D H44 x W263 x D170 mm Weight Net Gross 1 3kg 2 0kg 450z 700z Power 48VDC 2 5A 4pin DC inlet Operating Temp 0 C 40 C 82 F 104 F Storage Temp 40 C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 7 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 100W PoE power budget Size H x W x D H44 x W263 x D170 mm Weight Net Gross 1 3kg 2 0kg 450z 700z Power 48VDC 2 5A 4pin DC inlet Operating Temp 0 C
38. EE 802 1p DSCP CoS scheduling for classification and preferred high priority traffic Supports per port Ingress and Egress Rate Limiting Supports Dynamic Learning mode for Port Security function up to 24 MAC addresses can be learned for each port Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast multicast and unknown unicast storm control Supports Protected Port feature Supports SSL SSH secure access Supports Access Control List feature up to 256 rules can be configured Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Supports TACACS login authentication Supports DSCP remarking Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard w Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by Layer 2 2 Management Switch Series 64 using SNMP management applications su
39. IP mode packet type This command specifies the packet type Format access list name lt WORD gt set IP mode packet type ICMP IGMP IP TCP UDP GRE Mode Global Config 6 5 access list name lt WORD gt set mac mode Specify ACL entry priority 6 5 1 access list name lt WORD gt set mac mode mac SA This command specifies a source mac address Format access list name lt WORD gt set mac mode mac SA lt mac addr gt lt mask addr gt Mode Global Config 6 5 2 access list name lt WORD gt set mac mode mac DA This command specifies a destination mac address Format access list name lt WORD gt set mac mode mac DA lt mac adar gt lt mask addr gt Mode Global Config 6 6 access list name lt WORD gt set mac mode ether type This command specifies the ether type of the packet Format access list name lt WORD gt set mac mode ether type ipv4 ARP xns Mode Global Config 7 access list name lt name gt set portlist Note This command only supports on the following switches 2 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command is used to specify an acl entry to be work on a list of ports Format access list name lt name gt set portlist lt LINE port_id gt Mode
40. J 45 ports for automatic adjustment of wiring errors Throughput Up to 8 8 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering m Provides non blocking switching performance Provides a RS 232 port for system configuration Layer 2 2 Management Switch Series 72 N 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Supports 24 ports 100Base TX and 2 1000BaseT with 2 shared Mini GBIC User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports IEEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput Up to 8 8 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering m Provides non blocking switching performance Provides a RS 232 port for system configuration Flexible TCAM based Compact Field Process for packet classification and filtering Layer 2 2 Management Switch Series 73 2 48 Port 10
41. Mode User Mode enable Enter into the Privileged Mode Format enable Mode User Mode Layer 2 2 Management Switch Series 22 Save This command is used to save configurations Note This feature only supports on the following switches 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 3 3 2 Privileged Mode commands cable diag This command is used to proceed cable diagnostic Format cable diag port lt port D gt Mode Privileged Mode e g Switch cable diag port 1 clear 1 clear arl This command is used to clear ARL table entries 1 1 clear arl dynamic This command is used to Clear dynamic arl table entries Format clear arl dynamic Mode Privileged Mode 1 2 clear arl static This command is used to clear static arl table entries Format clear arl static mac lt mac addr gt Mode Privileged Mode 2 clear config This command is used to restore switch factory default configuration Format clear config Mode Privileged Mode 3 clear counters This command is used to clear RMON statistics for entire switch Format clear counters Mode Privileged Mode 4 clear igmpsnooping This command is used to restore igmpsnooping configuration to factory default Format clear igmpsnooping Mode Privileged Mode 5 clear static mcast This command is used to clear static multicast groups Format clear static mcast Mode Privileged Mode 6 clear pass This command is used to restore administra
42. TX 2 Gigabit combo Layer 2 Management Switch xsi2 ccni0s cceviegso esgent cmnente ed esseesepantdanteaesscecumcgenrneal 6 2 2 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch cc ccceeeeeeeeeeeeneeeeeeeeeeeeeeeeeaaees 6 2 2 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management SWItehi eres te cc aches ou de Sasa iaeaea ieaiai ine din detec cies 7 2 2 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch ccccceeceeeeeeeceeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeeenaeeeeeeees 8 2 2 6 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget 8 2 2 7 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 port embedded 100W PoE power DMOG GE esish tesa acca Meet taba Aeon esha N Naa 9 2 2 8 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch ee wots dees ce npecteaendhse te cen tanita dere oad csesal caidas 10 2 2 9 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 180W PoE power D dget aiarar N Seance ot ceet tes a usr chert e aa 11 2 2 10 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch De SktOp ceeeeeeeeeeeeeeeeeeeeeeeeeeeetneeeeeeeees 11 2 2 11 8 Port 100Base TX 2 Gigabit Combo L2 Manaugement SSV IKO A AREA EE EEA aes cats EEEE EE 12 23 CED FUGON e a A A 13 2 4 Reset Button nnsnsns
43. UTP Category 5 Unshielded Twisted Pair Ethernet cabling in precrimped lengths or you can crimp your own Crimping your own can result in faulty connections if the RJ 45 tips are not attached properly Precrimped Category 5 cabling is available at most computer retail stores The most reliable and commonly used type of Category 5 cabling used is UTP or unshielded twisted pair STP or shielded twisted pair wiring is only necessary for network environments exposed to excessive amounts of electromagnetic interference or EMI These environments include areas with high sources of electrical power air conditioning generators and radio signals STP is also used for wiring outdoors There are two types of the wiring Straight Through Cables and Crossover Cables Category 5 UTP STP cable has eight wires inside the sheath The wires form four pairs Straight Through Cables has same pinouts at both ends while Crossover Cables has a different pin arrangement at each end In a straight through cable wires 1 2 3 4 5 6 7 and 8 at one end of the cable are still wires 1 8 at the other end In a crossover cable the wires of 1 2 3 6 are reversed so that wire 1 become 3 at the other end of the cable 2 becomes 6 and so forth To determine which wire is wire 1 hold the RJ 45 cable tip with the spring clip facing towards the ground and the end pointing away from you The copper wires exposed upwards to your view The first wire on the far left is wire
44. ace for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Supports TACACS login authentication Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP m Supports GVRP A oO Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection Supports Auto Dos 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Layer 2 2 Management Switch Series 65 Switch Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View Supports IGMP snooping to limit flooding of IP multicast traffic and filtering for controlling the set of multicast groups to which hosts on a switch port can belong Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Supports IEEE 802 3ad Link Aggregation up to 14 LAG grou
45. anning Tree Protocol STP provides you a loop free network The IGMP snooping enables you to have efficient network usage in IP multicast environment The one to one or many to one Port Mirroring feature of the switch enables you to monitor the traffic on the network With these features you can build or expand your network quickly and easily 1 1 Package Contents These L2 L2 Management Switches package contains the following gt One L2 L2 Management Switch gt One RS 232 cable gt One power cord adapter gt One set of brackets gt One CD for user manual and utilities If any of the listed items is missing or damaged please contact the place of purchase 1 2 How to Use this Guide This user guide is structured as follows Chapter 2 Installation explains the functions of the switch and how to physically install it Chapter 3 Configuration explains how to set up and modify the configuration of the switch Chapter 4 Specifications contains information about the cables and the technical specifications of the switch Appendices include the Warranty Statement Read them as necessary Layer 2 2 Management Switch Series 4 2 Installation This chapter describes the function of the management switch components and shows how to install it on the desktop or shelf Basic knowledge of networking is assumed Read this chapter completely before continuing 2 1 Product Description Overview These products are all L2 L
46. cations keep in mind that the maximum UTP cabling length of Category 5e cable is 328 feet 100 meters Positioning the switch When choosing a location for the switch observe the following guidelines Keep enough ventilation space between the switch and the surrounding objects Keep cabling away from sources of electrical noise power lines and fluorescent lighting fixtures Do not stack free standing switch more than four units high Desktop or Shelf Mounting To install the switch on a desktop or shelf simply complete the following steps Step 1 Place the switch on a desktop or shelf near an AC power source Step 2 Keep enough ventilation space between the switch and the surrounding objects Note When choosing a location keep in mind the environmental restrictions discussed in Chapter 4 Specifications Step 3 Connect the switch to network devices A Connect one end of a standard network cable to the RJ 45 ports on the front of the switch B Connect the other end of the cable to the network devices such as printer servers workstations or routers Note It is recommended to use the UTP Category 5e network cabling with RJ 45 tips for the network connection For more information please see the Cable Specifications in Chapter 4 Specifications Layer 2 2 Management Switch Series 16 Step 4 Supply power to the switch A Connect one end of the power cable to the switch B Connect the power cube end of the power cable to a
47. ch as HP Open View Supports IGMP snooping to limit flooding of IP multicast traffic and filtering for controlling the set of multicast groups to which hosts on a switch port can belong Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Supports IEEE 802 3ad Link Aggregation up to 6 LAG groups and 8 ports for each LAG group Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports many to one one to one Port Mirroring function Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high priority traffic Supports per port Ingress and Egress Rate Limiting Supports Dynamic Learning mode for Port Security function up to 24 MAC addresses can be learned for each port Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast multicast and unknown unicast storm control Supports Protected Port feature Supports SSL SSH secure access Supports Access Control List feature up to 128 rules can be configured Supports web based interface for management Supports CLI interf
48. d 10 reindex 1 feindex 0 owner test 3 rmon del 3 1 rmon del event This command deletes rmon event entry Format rmon del event index lt 1 65535 gt Mode Global Config 3 2 rmon del alarm This command deletes rmon alarm entry Format rmon del alarm index lt 1 65535 gt Mode Global Config access list Note This commands only support on L2 Management Switches 1 access list name lt WORD gt add This command creates a new access list Format access list name lt WORD gt add priority lt 1 65535 gt Mode Global Config 2 access list name lt WORD gt action 2 1 access list name lt WORD gt action deny This command denies an ACL entry Format access list name lt WORD gt action deny Mode Global Config 2 2 access list name lt WORD gt action permit This command permits an ACL entry and queue 1 4 will assign priority queue when rule activated Format access list name lt WORD gt action permit lt cr gt queue lt 1 4 gt Mode Global Config 3 access list name lt WORD gt clear This command clears ACL entry contents 3 1 access list name lt WORDs gt clears SRC IP This command clears the source IP subnet mask filter Format access list name lt WORD gt clear SRC IP Mode Global Config 3 2 access list name lt WORD gt clears DST IP This command clears the destination IP subnet mask filter Format access list name lt WORD gt clear DST IP Mode Global Config 3 3 access list name lt WORDs gt
49. de Layer 2 Management Switch i 1 ELL E f PAR umia 5 6 7 s 7 uaaa G2 oom mieGBIC 2 Figure 2 2 8b Rear Panel Power Table 2 2 8c Port Function Port Function 1 8 This where you connect the Cat 3 5 5e or better Layer 2 2 Management Switch Series 10 ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2__ ethernet cable for 10 100 1000 Mbps ethernet connection ini This is where you connect the SFP module for fiber miniGBIC connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the DC power adapter 2 2 9 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 180W PoE power budget The front panel of this switch has 24 10 100 Mbps copper ports at the left with 2 shared Gigabit SFP slots at the right And the left 12 10 100 Port embedded with PoE PSE function Figure 2 2 9a shows a front panel of the switch The rear panel has a power and console connector and Figure 2 2 9b shows a rear panel of the switch Table 2 2 9c shows the port function of the switch Figure 2 2 9a Front Panel TTT wr TTT WT TT Pee oe MMRR a oe way Figure 2 2 9b Rear Panel Power Table 2 2 9c Port Function Port Function 24 This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where yo
50. de Global Config 2 2 link aggregation delport lag This command remove specify LAG group Format link aggregation delport lag lt LAG ID gt Mode Global Config Ildp 1 Ildp enable This command is used to enable Ildp functions Layer 2 2 Management Switch Series 34 Format Ildp enable Mode Global Config 2 lldp disable This command is used to disable Ildp functions Format Ildp disable Mode Global Config 3 Ildp adv interval This command is used to specify advertised interval in seconds Format lIldp adv interval lt 5 32768 gt Mode Global Config 4 Ildp fast startcnt This command is used to specify fast start count Format lldp fast startcnt lt 1 10 gt Mode Global Config 5 Ildp hold This command is used to specify hold value Format Ildp hold lt 2 10 gt Mode Global Config 6 Ildp notify interval This command is used to specify notification interval in seconds Format lIldp notify interval lt 5 3600 gt Mode Global Config 7 lldp reinit delay This command is used to specify re initialization delay in seconds Format lldp reinit delay lt 1 10 gt Mode Global Config 8 lldp tx delay Transmit Delay in seconds Format Ildp tx delay lt 1 8192 gt Mode Global Config 9 Ildp mgmt addrtxport A range of ports can be set Format ldp mgmt addrtxport ports lt port list gt Mode Global Config e g switch config lldp mgmt adartxport ports 1 switch config Ildp mgmt addrtxport ports 1 4 log Thi
51. de is Jan 21 2009 Version 1 0k FCC Statement This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against such interference when operating in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used according to the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user at his or her own expense will be required to take whatever measures to correct the interference CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Layer 2 2 Management Switch Series 2 1 5 Table of Contents INTFOGUCHION PA E ETT E 4 1 1 Package COMTI sissies osc deen lesen dele eneadesnntens ded cen dteeeh 4 12 How to USE IIS GUAE diiirn 4 INS tal OM ieena aiaia aaea e eaaa aaa ai eaaa eaaa aia enida iaaiiai 5 2 1 Product Description Overview ccceeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeeeeeee 5 2 2 Switch Front and Rear Panel ssisiascsstessessdiraewdisteacarcceasesisdeseatgersentast 5 2 2 1 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management sWiiGhit insta ta ia oA he aon aria 5 2 2 2 24 Port 100Base
52. e This command enables disables the ACL entry Format access list name lt WORD gt enable disable Mode Global Config 6 access list name lt WORD gt set 6 1 access list name lt WORDsS set priority This command specifies ACL entry priority Format access list name lt WORD gt set priority lt 0 65535 gt Mode Global Config 6 2 access list name lt WORD gt set IP mode 6 2 1 access list name lt WORD gt set IP mode SRC IP This command specifies a source IP address Format access list name lt WORD gt set IP mode SRC IP lt IP addr gt lt mask addr gt Mode Global Config 6 2 2 access list name lt WORD gt set IP mode DST IP This command specifies a destination IP address Format access list name lt WORD gt set IP mode DSP IP lt P addr gt lt mask addr gt Mode Global Config 6 3 access list name lt WORDs gt set L4port Layer 2 2 Management Switch Series 48 This command specifies the TCP UDP port range 6 3 1 access list name lt WORDs gt set l4port SRC port This command specifies the source TCP UDP port range Format Access list name lt WORD gt set L4 port SRE port from lt 1 65535 gt to lt 1 65535 gt Mode Global Config 6 3 2 access list name lt WORDs gt set l4port DST port This command specifies the destination TCP UDP port range Format access list name lt WORD gt set l4port DST port from lt 1 65535 gt to lt 1 65535 gt Mode Global Config 6 4 access list name lt WORDs gt set
53. e Interface Config addport add one port to a LAG group Format addport lt LAG D gt Mode Interface Config delport Remove a port from a LAG group Format delport lt LAG D gt Mode Interface Config Ildp An Ildp agent can transmit information about the capabilities and current status of the system associated with its MSAP identifier The Ildp agent can also receive information about the capabilities and current status of the system associated with a remote MSAP identifier However Ildp agents are not provided any means of soliciting information from other Ildp agents via this protocol 1 Ildp state set Only transfer the Ildp status Format lldp state tx rx tx_rx disable Mode Interface Config 2 configure notifications Enable disable notification form the agent Format lldp notification enable disable Mode Interface Config 3 Configures which TLVs are enabled for transmission 3 1 basic set Layer 2 2 Management Switch Series 55 Format Ildp tlvs tx enable disable option basic port desc sys name sys desc sys capa_ Mode Interface Config 3 2 8021 set Status of local 802 1 settings Format Ildp tlvs tx enable disable option 8021 pvid vianname protocol id Mode Interface Config eg switch interdface 1 lldp tlvs enable option 8021 pvid 1 3 3 8023 set Format _ lldp tlvs tx enable disable option 8023 mac phy power link aggregation frame size Mode Interface Config admin m
54. e RS 232 cable for CLI management Power This is where you connect the DC power adapter 2 2 11 8 Port 100Base TX 2 Gigabit Combo L2 Manaugement Switch The front panel of 8 Port 100BaseTX 2 Gigabit Combo L2 Management Switch has 8 10 100 Mbps copper ports at the left 2 10 100 1000 Mbps copper ports and 2 Gigabit SFP slots at the right The product name indicates at the top on the middle Figure 2 2 11a shows a front panel of this switch The rear panel has a power connector and figure 2 2 11b shows a rear panel of the switch Table 2 2 11c shows the port function of the switch Figure 2 2 11a Front Panel Layer 2 2 Management Switch Series 12 8 Port 100BaseTX 2 Gigabit Combo Layer 2 Management Switch Figure 2 2 11b Rear Panel Table 2 2 11c Port Function Port Function 1 8 This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2 ethernet cable for 10 100 1000 Mbps ethernet connection me This is where you connect the SFP module for fiber miniGBIC connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the DC power adapter 2 3 LED Function This section explains the definition of the Switch s LEDs on the front panel 1 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch 2 24 Port 100BaseTX
55. eT with 2 shared Gigabit SFP Layer 2 Management Switch oon Sanit 82882 222 i iici Fee VEVE FETT E i Hit Figure 2 2 4b Rear Panel Power Table 2 2 4c Port Function Port Function 1 24 This where you connect the Cat 5e or better ethernet cable for 10 100 1000 Mbps ethernet connection This is where you connect the SFP module for fiber miniGBIC connection Gondola This is where you connect the RS 232 cable for CLI management Power This is where you connect the AC power cord Layer 2 2 Management Switch Series 7 2 2 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch The front panel of 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch has 48 10 100 1000 Mbps copper ports at the left with 4 shared Gigabit SFP slots at the right The product name indicates at the top on the right Figure 2 2 5a shows a front panel of the switch The rear panel has a power and console connector and Figure 2 2 5b shows a rear panel of the switch Table 2 2 5c shows the port function of the switch Table 2 2 5c Port Function Port Function This where you connect the Cat 5e or better 1 48 ethernet cable for 10 100 1000 Mbps ethernet connection ee This is where you connect the SFP module for fiber miniGBIC connection Console This is where you connect the RS 232 cable for CLI management Power This is whe
56. em link SNMP Management You can manage the switch across a LAN using an SNMP Network Management Station with a graphical user interface Note that to use this management method your network must use the IP protocol and your switch must be configured on the Network with a proper IP address You may use any of the following method to manage the switch Web Browser You can manage the switch through a web connection by connecting to the switch s IP address using your web browser This User Guide provides instructions on how to configure the switch using the console interface Read the following sections to start up Connecting a PC or Terminal to the RS 232 Port When you are ready to configure the Management Function of the switch make sure you have connected the supplied RS 232 serial cable to the RS 232 port at the front panel of your switch and your PC Terminal Emulation Setup Program Run a terminal emulation program with the following setting Emulation VT 100 compatible Baud per second 38400 Data bits 8 Parity None Stop bits 1 Layer 2 2 Management Switch Series 19 Flow Control None Logging on to the switch Enter the factory default user name admin with no password when logging on to the switch The password is set to be empty If you can enter on the command line screen it will displays all items so that you can configure by your requirements 3 2 Web based configuration The Switch provide
57. em_image exit This command is used to exit current shell Format exit Mode Privileged Mode help This command displayss help information Format help Mode Privileged Mode logout This command is used to exit current shell Format logout Mode Privileged Mode ping Layer 2 2 Management Switch Series 24 This command is used to proceed ping destination host Format ping lt A B C D gt Mode Privileged Mode reload This command is used to reboot system Format reload Mode Privileged Mode save This command is used to save configuration Format save Mode Privileged Mode show This command is used to show configured data 1 show gos This command displays class of service information 1 1 show qos cos This command displays the cos mapping Format show qos cos Mode Privileged Mode 1 2 show qos queue settings This command displays the queue settings mapping Format show qos queue settings Mode Privileged Mode 1 3 show qos advanced This command displays qos advanced mode information 1 3 1 show qos advanced mode This command displays mode of qos Format show qos advanced mode Mode Privileged Mode 1 3 2 show gos advanced dscp This command displays qos dscp mapping Format show qos advanced dscp Mode Privileged Mode 1 3 3 show qos advanced ip precedence This command displays gos ip precedence mapping Format show qos advanced ip precedence Mode Privileged Mode 1 4 show qos port based This command
58. ersion lt 1 2 gt Mode Global Config 2 2 snmp group delete This command delete a snmp group Format snmp group delete lt WORD gt Mode Global Config 3 snmp user 3 1 snmp user add This command creates a snmp user Format snmp user add lt user name gt group lt group name gt version lt 1 3 gt Mode Global Config 3 2 snmp user delete This command deletes a snmp user Format snmp user delete lt WORD gt Layer 2 2 Management Switch Series 42 Mode Global Config 4 snmp community 4 1 snmp community add This command creates a community Format snmp community add lt community name gt group lt group name gt mgmt ip lt p addr gt Mode Global Config 4 2 snmp community delete This command deletes a community Format snmp community delete lt community name gt Mode Global Config 5 snmp trapstation 5 1 snmp trapstation add Create a snmp trap station 5 1 1 snmp trapstation add lt ip addr gt community lt community name gt type bootup Send trap when system reboot Format snmp trapstation add lt i p addr gt community lt community name gt type bootup trap version 1 2 Mode Global Config 5 1 2 snmp trapstation add lt ip addr gt community lt community name gt type linkchange Send trap when port link change Format snmp trapstation add lt ip addr gt community lt community name gt type linkchange trap version 1 2 Mode Global Config 5 1 3 snmp trapstation add lt ip addr gt com
59. es storm control for broadcast multicast and unknown unicast Format port all Storm Control all cast lt value gt Mode Global Config qos 1 qos qos advanced Configure qos advanced mode 1 1 qos qos advanced DSCP This command enables DSCP mode Format qos qos advanced DSCP Mode Global Config 1 2 qos qos advanced ip_precedence This command enables IP Precedence mode Format qos qos advanced ip_ precedence Mode Global Config 1 3 qos qos advanced none This command disables qos advanced mode Format qos gos advanced none Mode Global Config 2 qos cos This command configures 802 1p priority queue mapping Format Qos cos priority lt 0 7 gt queue lt 1 4 gt Mode Global Config 3 qos dscp This command specifies dscp value to queue mapping Format qos dscp lt 0 63 gt queue lt 1 4 gt Mode Global Config 4 qos port based This command configures port based priority mapping Format qos port based port lt WORD gt status enable disable Mode Global Config 5 qos scheduling Configure qos scheduling mode 5 1 qos scheduling strict This command sets to strict priority Format qos scheduling strict Layer 2 2 Management Switch Series 40 Mode Global Config 5 2 qos scheduling wrr This command sets to Weight Round Robin Format qos scheduling wrr Mode Global Config 6 qos ip precedence This command configures IP precedence queue mapping Format qos ip precedence lt 0 7 gt queue lt 1 4 gt M
60. ginal proof of purchase All customers outside the R O C shall be held responsible for shipping and handling charges In no event shall our liability exceed the price paid for the product from direct incidental or consequential damage resulting from the use of the product its accompanying software or its documentation We make no warranty or representation expressed implied or statutory with respect to its products or the contents or use of this documentation and all accompanying software and specifically disclaim its quality performance merchantability or fitness for any particular purpose We reserve the right to revise or update its products software or documentation without obligation to notify any individual or entity Layer 2 2 Management Switch Series 85
61. gress Rate Limiting Minimum rate is 64 Kbps granularity is 64 Kops Supports Static Mode and Dynamic Learning Mode for Port Security function Support up to 24 MAC addresses for each port Supports Protected port feature Supports SSL SSH secure access Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast known multicast and unknown unicast storm control Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Layer 2 2 Management Switch Series 67 Supports TACACS login authentication Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View IGMP snooping support to limit flooding of IP multicast traffic and filtering for controlling the set of multicast groups to which hosts on a switch port can belong S
62. heduling for classification and preferred high priority traffic Supports per port Ingress and Egress Rate Limiting m Supports Dynamic Learning mode for Port Security function up to 24 MAC addresses can be learned for each port Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Layer 2 2 Management Switch Series 71 Supports broadcast multicast and unknown unicast storm control Supports Protected Port feature m Supports SSL SSH secure access Supports IP MAC Access Control List feature up to 256 rules Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Supports TACACS login authentication Supports DSCP remarking Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 4 2 2 Hardware Specification as 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Supports 24 ports 100Base TX and 2 1000BaseT with 2 shared Mini GBIC User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports IEEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all R
63. ileged Mode 28 2 show ipsrcgd ports This command is used to displays ports which enabled IP Source Guard Format show ipsrcgd ports Mode Privileged Mode 28 3 show ipsrcgd database This command is used to displays the database of IP Source Guard Format show ipsrcgd database Mode Privileged Mode 29 show https This command is used to displays https information Format show https Mode Privileged Mode 30 show loop_detect This command is used to displays selfloop detect information Format show loop_detect Mode Privileged Mode telnet This command is used to telnet the other host Format telnet lt A B C D gt Mode Privileged Mode 3 3 3 Global Config mode commands exit This command is used to exit current shell Format exit Mode Global Config vlan This command is used to configure vlan 1 vlan add This command is used to create a new vlan or some vlans 1 1 vlan add number This command enter a vlan ID Layer 2 2 Management Switch Series 32 Format vlan add number lt vian D gt Mode Global Config 1 2 vlan add range This command enter a range of vlan ID Format vlan add range from lt vlan ID gt to lt vian ID gt Mode Global Config 2 vlan delete This command remove a existed vlan Format vlan delete lt v an D gt Mode Global Config 3 vlan ingress Note This command only supports on the following switches 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch This com
64. ing functions Format dhcpsnooping enable Mode Global Config 3 dhcpsnooping option82 Layer 2 2 Management Switch Series 51 This command is used to set option82 packets Format dhcpsnooping option82 enable disable Mode Global Config 4 dhcpsnooping verifymac enable This command is used to set verify mac address Format dhcpsnooping verifymac enable disable Mode Global Config 5 dhcpsnooping ports This command is used to set ports to trust or untrust 5 1 dhcpsnooping ports trust This command is used to set ports to trust Format dhcpsnooping ports trust lt port list gt Mode Global Config 5 2 dhcpsnooping ports untrust This command is used to set ports to untrust Format dhcpsnooping ports untrust lt port list gt Mode Global Config 6 dhcpsnooping vian This command is used to configure dhcp vlan 6 1 dhcpsnooping vlan add This command is used to enable dhcp snooping in a specified vlan Format dhcpsnooping vlan add from lt vlan id gt to lt vlan id gt Mode Global Config 6 2 dhcpsnooping vian This command is used to disable dhcp snooping in a specified vian Format dhcpsnooping vlan remove from lt vlan id gt to lt vian id gt Mode Global Config 7 dhcpsnooping static This command is used to configure dhcp static entry 7 1 dhcpsnooping static add This command is used to add a static dhcp entry Format dhcpsnooping static add ip lt A B C D gt mac lt mac address gt port lt port id gt vid lt vlan id gt Mode Global Config 7
65. ity Normal Set to normal priority Middle Set to middle priority High Set to high priority Format poe power pri level low normal middle high Mode Interface Config 3 detection This command configures detection type on a port set to 0 1 2 3 4 or 5 No Detection Legacy Capacitive Detection only IEEE 802 3af 4 Point Detection only Default IEEE 802 3af 4 Point followed by Legacy IEEE 802 3af 2 Point only IEEE 802 3af 2 Point followed by Legacy Format poe detection type 0 1 2 3 4 5 Mode Interface Config 4 high power This command configures power Energy Mode on a port on Start High Power Support 30W power device off End High Power Mode Support 15 4W power device Format poe high power status on off Mode interface Config akRWNM oO Layer 2 2 Management Switch Series 60 4 Specifications 4 1 Cable specifications Straight Through and Crossed Over Cable Specifications Table Ethernet Type Cable Requirements Maximum Length 10BASE T Category 3 or better UTP or STP 328 ft 100M 100BASE TX _ Category 5 or better UTP or STP 328 ft 100M 1000BASE T Category 5e or better UTP or STP 328 ft 100M Caution Please do not use telephone cables Telephone cables do not support Ethernet or Gigabit Twisted pair cabling comes in various grades or categories Category 5 is required for Fast Ethernet and is also the most reliable and most commonly used category You can buy
66. justment of wiring errors Throughput up to 48 Gbps Provides IEEE802 3x Flow Control mechanism ensures zero packet loss which uses Back Pressure for half duplex operation and Flow Control for full duplex operation Supports 8K MAC address and Up to 4Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides non blocking switching performance Supports Jumbo Frame up to 9KB Provides a RS 232 port for system configuration Flexible TCAM based Compact Field Process for packet classification and filtering Layer 2 2 Management Switch Series 75 ol 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch Supports 48 ports 10 100 1000 Mbps copper ports with 4 shared mini GBIC slots User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports Supports half duplex and full duplex modes and auto negotiation for all 10BASE T 100BASE TX 1000BASE T ports IEEE 802 3ab Auto MDI MDI X on all 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput up to 96 Gbps Provides IEEE802 3x Flow Control mechanism ensures zero packet loss which uses Back Pressure for half duplex operation and Flow Control for full duplex operation Supports 8K MAC address and up to 4Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides
67. left 4 10 100 1000 Mbps copper ports with 2 shared Gigabit SFP slots at the right The product name indicates at the top on the right Figure 2 2 3a shows a front panel of the switch The rear panel has a power connector and Figure 2 2 3b shows a rear panel of the switch Table 2 2 3c shows the port function of the switch Figure 2 2 3a Front Panel Layer 2 2 Management Switch Series 6 Figure 2 2 3b Rear Panel Power Table 2 2 3c Port Function Port Function 1 48 This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G4 ethernet cable for 10 100 1000 Mbps ethernet connection n This is where you connect the SFP module for fiber miniGBIC i connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the AC power cord 2 2 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch The front panel of 24 Port 1000BaseT with 2 shared Gigabit SFP L2 Management Switch has 24 10 100 1000 Mbps copper ports at the left with 2 shared Gigabit SFP slots at the right The product name is at the top on the left Figure 2 2 4a shows a front panel of this switch The rear panel has a power connector and Figure 2 2 4b shows a rear panel of the switch Table 2 2 4c shows the port function of the switch Figure 2 2 4a Front Panel 24 Port 10008es
68. mand performs ingress vlan source port membership check 3 1 vlan ingress forward The command is used to forward frame but don t learn SA into ARL table Format vlan ingress forward Mode Global Config 3 2 vlan ingress drop This command is used to drop frames violation vid Format vlan ingress drop Mode Global Config 3 3 vlan ingress bypass This command is used to forward frame and learn SA into ARL table Format vlan ingress bypass Mode Global Config 4 vlan port This command is used to configure 802 1Q port parameters for vians 4 1 vlan port all This command is used to configure all ports 1 1 vlan port all port configure This command is used to configure ports in a specific vlan Format vlan port all port configure lt vian D gt Mode Global Config 1 2 vlan port all protected This command is used to configure protected ports Format vlan port all protected enable disable Mode Global Config 1 3 vlan port all pvid This command is used to configure port pvid Format vlan port all pvid lt vian D gt Mode Global Config 4 2 vlan port ports This command is used to configure multiple ports 4 2 1 vlan port ports port configure This command is used to configure ports in a specific vlan Format vlan port ports port configure lt vian D gt Mode Global Config 4 2 2 vlan port ports protected This command is used to configure protected ports Layer 2 2 Management Switch Series 33 Format vlan port ports
69. modem protocol for firmware configuration upgrade or backup Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 11 8 Port 100BaseTX 2 Gigabit Combo L2 Management Switch Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View Supports IGMP snooping to limit flooding of IP multicast traffic and filtering for controlling the set of multicast groups to which hosts on a switch port can belong Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Supports IEEE 802 3ad Link Aggregation up to 3 LAG groups and 4 ports for each LAG group Built in DHCP client to get IP address from DHCP server automatically m Supports SNTP to synchronize the precision time with Internet Time server Supports many to one one to one Port Mirroring function Supports for IEEE 802 1p DSCP CoS sc
70. munity lt community name gt type both Send trap when system reboot or port link change Format snmp trapstation add lt p addr gt community lt community name gt type both trap version 1 2 Mode Global Config 5 1 4 snmp trapstation add lt ip addr gt community lt community name gt type none Send no trap Format snmp trapstation add lt p addr gt community lt community name gt type none trap version 1 2 Mode Global Config 5 2 snmp trapstation delete This command delete a trap station Format snmp trapstation delete lt WWORD gt Mode Global Config snip 1 sntp daylight This command enables or disables the daylight saving configuration Format sntp daylight enable disable Mode Global Config 2 sntp localtime Configure the local time 2 1 sntp localtime enable Layer 2 2 Management Switch Series 43 This command enables local time Format snip localtime enable Mode Global Config 2 2 sntp localtime localtime_date This command sets local time Format sntp localtime localtime_date lt year gt lt month gt lt date gt lt hour gt lt minute gt lt second gt Mode Global Config 3 sntp server 3 1 sntp server enable This command enables sntp server Format sntp server enable Mode Global Config 3 2 sntp server ipaddr This command sets sntp server IP address Format sntp server ipaddr lt P addr gt Mode Global Config 3 3 sntp server polling This command sets sntp server polling
71. n history lt CR gt Format show rmon history lt CR gt Mode Privileged Mode 22 5 show rmon statistics This command displayss port summary statistics Format Show rmon statistics lt port index gt Mode Privileged Mode 23 show poe This command is used to displays poe mode and settings displays poe port status 23 1 show poe port index Layer 2 2 Management Switch Series 30 This command is used to specify an switch poe interface Format show poe port index lt port ID gt Mode Privileged Mode 23 2 show poe all This command is used to displays all switch poe interface Format show poe all Mode Privileged Mode 23 3 show poe system status This command is used to displays PoE system status Format show poe system status Mode Privileged Mode 24 show tacplus This command is used to displays TACACS information includes authentication type and server parameters Format show tacplus Mode Privileged Mode 25 show arp This command is used to displays table of static ARP Format show arp Mode Privileged Mode 26 show acl This command is used to displays information about ACL entries Format show acl Mode Privileged Mode 27 show dhcpsnooping Note These commands only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command is used to display dhcp snooping information 27 1 show dhcpsnooping config Thi
72. ng switches This command enable limited dynamic lock mode and specify maximin learning entries for limited dynamic lock mode the max entries value 0 24 Format port security lock mode dynamic max entries 24 Mode Interface Config 4 port security none Note This feature only supports on the following switches 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch qos Note This feature only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command specifies port based qos priority mapping Format qos port based priority lt 0 7 gt Mode Interface Config Qos port based status Note This command only support on the following switch 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch This command is used to set port based status Format qos port based status enable disable Mode Interface Config rate limit rate limit egress 1 1 rate limit egress enable This command limits egress rate which the unit is Kbps Format rate limit egress enable token bsize lt Burst Size Value gt Mode Interface Config 1 2 rate limit egress disable This command disable egress rate limit 2 rate limit ingress This command limits ingress rate which the unit is Kbps Format rate limit ingress lt rate gt Mode Interface Config storm control 1
73. ng tree cost This command configure RSTP port path cost path cost value 0 200000000 Format spanning tree cost lt pathcost Mode Interface Config 2 spanning tree edge This command configure edge property Format spanning tree edge enable disable Mode Interface Config e g Switch Interface 1 spanning tree edge enable 3 spanning tree force p2plink This command configure force point to point link mode Format spanning tree force p2plink auto enable disable Mode Interface Config 4 spanning tree migration check This command re checks the appropriate BPDU format to send on this port Format spanning tree migration check enable disable Mode Interface Config 5 spanning tree mst This command configures multiple spanning tree instance 5 1 spanning tree mst cost This command configure the path cost on a MST instance 1 200000000 Format spanning tree mst cost lt MST ID gt lt pathcost gt Layer 2 2 Management Switch Series 58 Mode Interface Config 5 2 spanning tree mst priority This command configure the port priority on a MST instance 0 4094 Format spanning tree mst priority lt 0 4094 gt lt 0 240 gt Mode Interface Config 6 spanning tree participation This command configures RSTP capability on a port Format spanning tree participation enable disable Mode Interface Config 7 spanning tree priority this command configure RSTP port priority 0 240 format spanning tree priority lt 0 240 gt mode Inte
74. non blocking switching performance Supports Jumbo Frame up to 9KB Flexible TCAM based Compact Field Process for packet classification and filtering Layer 2 2 Management Switch Series 76 6 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget Supports 8 ports 100Base TX with PoE PSE and 2 1000BaseT with 2 shared Mini GBIC User configurable 100FX or 1000Base SX LX mini GBIC fiber module on mini GBIC ports IEEE 802 3ab Auto MDI MDI X on all 10 100 1000 twisted pair ports Automatic polarity detection and correction on all RJ 45 ports for automatic adjustment of wiring errors Throughput Up to 5 6 Gbps Provides Flow Control mechanism ensures zero packet loss IEEE802 3x Flow Control for full duplex operation and Back Pressure for half duplex operation Supports 8K MAC address and Up to 3Mb packet buffer Supports Store amp Forward architecture and performs forwarding and filtering Provides non blocking switching performance Provides a RS 232 port for system configuration Total Power Budget 100 W with 8 W guard band It means system can provide total 92 W power to power devices Supports 30 W high power devices Layer 2 2 Management Switch Series 77 7 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 100W PoE power budget Supports 24 ports 100Base TX with 12 ports PoE PSE and 2 1000BaseT with 2 shared Mini GBIC User
75. o by the specific mac address Format show switch mac Mode Privileged Mode 20 show trapflags This command is used to displays the value of trap flags that apply to the Layer 2 2 Management Switch Series 29 switch Format show trapflags Mode Privileged Mode 21 show vian This command is used to displays vlan configuration 21 1 show vlan member This command displays vlan configuration Format show vlan member lt 7 4094 gt Mode Privileged Mode 21 2 show vian number This command displays how many vlans has been created Format show vian number Mode Privileged Mode 22 show rmon This command displays rmon information 22 1 show rmon event 22 1 1 show rmon event Index This command displays rmon event table Format show rmon event index lt 1 65535 gt Mode Privileged Mode 22 1 2 show rmon event Format Show rmon event lt CR gt Mode Privileged Mode 22 2 show rmon event log This command displays rmon event log Format Show rmon event log event _index lt 1 65535 gt Mode Privileged Mode 22 3 show rmon alarm 22 31 show rmon alarm index This command displays rmon Alarm table Format show rmon alarm index lt 1 65535 gt Mode Privileged Mode 22 3 2 show rmon alarm Format show rmon alarm lt CR gt Mode Privileged Mode 22 4 show rmon history 22 4 1 show rmon history index This command displays enabled rmon history Format show rmon history index lt 1 65535 gt Mode Privileged Mode 22 4 2 show rmo
76. ode Configure administrative mode on a port Format Switch Interface 1 admin mode enable disable Mode _ Interface Config auto negotiate Configure auto negotiate mode on a port Format auto negotiate enable disable Mode Interface Config speed Set port speed to 10Mbps half duplex 10Mbps full 100Mbps half 100Mbps full 1000Mbps 100FX mode 1000base x full Format speed 10hd 10fd 100hd 100fd 1000fd 100fx 1000base x Mode Interface Config flow control This command enable disable flow control on ports Format flow control enable disable Mode Interface Config port security port security Note This feature only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command add or delete a static mac into mac security table Format port security add delete lt sourcemac gt Mode Interface Config port security lock mode Note This feature only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command disable port security or specify static lock mode Format _ port security lock mode none static Mode Interface Config port security lock mode dynamic Layer 2 2 Management Switch Series 56 Note This feature only supports on the followi
77. ode Global Config 7 qos wrr This command configures queue weight for weight round robin Format qos wrr weight lt 1 15 gt queue lt 1 4 gt Mode Global Config 8 qos dscp remark Note This command only supports on the following switches 2 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command is used to change DSCP value if the outgoing packet is an IP packet Select an ACL Entry Name as the criterion and then enter New DSCP Value as the action Once the criterion is hit the DSCP value will be changed Format qos dscp remark acl_entry_name lt name gt new_dscp_value lt 0 63 gt Mode Global Config set 1 set IGMP Configure IGMP snooping 1 1 set igmp enable This command enables igmp snooping Format set igmp enable Mode Global Config 1 2 set igmp disable This command disables IGMP snooping Format set igmp disable Mode Global Config 1 3 set igmp last memberquery This command specifies last member query interval Format set igmp last memberquery lt 1 200 gt Mode Global Config 1 4 set igmp last membercount This command specifies last member count Format set igmp last membercount lt 1 20 gt Mode Global Config 1 5 set igmp query interval This command specifies igmp query interval lt secs gt Format set igmp query interval lt 10 600
78. on type There are three types for selecting local tacplus localandtacplus Format tacplus authen_type local tacplus localandtacplus Mode Global Config 2 tacplus add This command is used to add a new TACACS server and set server IP address priority key string authentication port and timeout for reply Format tacplus add server lt IP_addr gt priority lt 0 65535 gt key lt key string gt port lt auth port id gt timeout lt 1 30 gt Mode Global Config 3 tacplus del This command is used to delete a TACACS server Format tacplus del server lt IP_addr gt Mode Global Config green eth Note This command only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command is used to enable disable green Ethernet function Enable green Ethernet mode will reduce system power consumption when the link is not present Format green eth enable disable Mode Global Config Dhcpsnooping Note This feature only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch 1 dhcpsnooping enable This command is used to enable dhcp snooping functions Format dhcpsnooping enable Mode Global Config 2 dhcpsnooping disable This command is used to disable dhcp snoop
79. p it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data PoE Amber LED lights up only when the corresponding port supply power 10 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Desktop PWR Green LED lights up it shows the system is powered up Link Act Green LED lights up it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data 1000M Amber LED lights up only when the corresponding port works at 1000Mbps 11 8 Port 100BaseTX 2 Gigabit Combo L2 Management Switch PWR Green When the power supplied to the system Link Act Green LED lights up it indicates a successful connection of that Layer 2 2 Management Switch Series 14 port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is activating and transmitting data Amber LED lights up only when the corresponding port works at 100Mbps 1000M Green LED lights up it indicates a successful connection of that port is established Otherwise it indicates the link is off or no link detected of that port When the LED blinks it indicates the port is
80. pports SSL SSH secure access Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP N Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View Supports IGMP snooping to limit flooding of IP multicast traffic and filtering Layer 2 2 Management Switch Series 63 for controlling the set of multicast groups to which hosts on a switch port can belong Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Supports IEEE 802 3ad Link Aggregation up to 6 LAG groups and 8 ports for each LAG group Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports many to one one to one Port Mirroring function Supports for IE
81. priority traffic Supports per port Ingress and Egress Rate Limiting Supports Dynamic Learning mode for Port Security function up to 24 MAC addresses can be learned for each port Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast multicast and unknown unicast storm control Supports Protected Port feature Supports SSL SSH secure access Supports Access Control List feature up to 256 rules can be configured Layer 2 2 Management Switch Series 69 Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Supports TACACS login authentication Supports DSCP remarking Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection 10 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Desktop Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View IGMP snooping support to limit flooding of IP multicast traffic and fil
82. ps and 8 ports for each LAG group Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports many to one one to one Port Mirroring function Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high priority traffic Supports per port Ingress and Egress Rate Limiting m Supports Dynamic Learning mode for Port Security function up to 24 MAC addresses can be learned for each port Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast multicast and unknown unicast storm control Supports Protected Port feature Supports SSL SSH secure access Supports Access Control List feature up to 256 rules can be configured Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Supports TACACS login authentication Supports DSCP remarking Supports DHCP Relay Supports IGMP Proxy Supports IGMP Querier Supports LLDP Supports GVRP Supports IGMP Immediate Leave Supports RSTP Root Guard Supports DHCP TFTP configuartion download Supports Port Self Loop Detection Supports DHCP Snooping Layer 2 2 Management Switch Series 66 o EN Supports Dynamic ARP Inspection Supports IP So
83. re you connect the AC power cord 2 2 6 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget The front panel of this switch has 8 10 100 Mbps copper ports at the left with 2 shared Gigabit SFP slots at the right The product name indicates at the top on the right Figure 2 2 6a shows a front panel of the switch The rear panel has a power and console connector and Figure 2 2 6b shows a rear panel of the switch Table 2 2 6c shows the port function of the switch Figure 2 2 6a Front Panel Layer 2 2 Management Switch Series 8 8 Port PoE PSE 10 100BaseTx 2 Gigabit Combo Layer 2 Management Switch Figure 2 2 6b Rear Panel Table 2 2 6c Port Function Port Function 1 8 This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2__ ethernet cable for 10 100 1000 Mbps ethernet connection a This is where you connect the SFP module for fiber miniGBIC connection Consale This is where you connect the RS 232 cable for CLI management Power This is where you connect the DC power adapter 2 2 7 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 port embedded 100W PoE power budget The front panel of this switch has 24 10 100 Mbps copper ports at the left with 2 shared Gigabit SFP slots at the right And the left 12 10 100 Por
84. rface Config vlan 1 vlan participation This command join or leave a pertte a vlan 1 1 vlan participation exclude This command is used to leave a vlan Format vlan participation exclude lt vlan id gt Mode Interface Config 1 2 vlan participation This command join a vlan with untagged tagged mode Format vlan participation untagged tagged lt vlan id gt Mode Interface Config 2 vlan protected This command configures port protected property Format vlan protected enable disable Mode Interface Config 3 vlan dropnq This command configure port drop none 802 1Q frame Format vlan dropnq enable disable Mode Interface Config 4 vlan pvid This command configure port PVID Format vlan pvid lt pvid gt Mode Interface Config e g Switch Interface 1 vlan pvid 1 Interface commands This command is used to change to another interface Format Interface lt port number gt Mode Interface Config e g Switch Interface 1 interface g1 poe 1 func This command configure poe function on a port Format poe func enable disable Mode Interface Config Layer 2 2 Management Switch Series 59 2 power pri This command configures the power priority on switch ports to decide which ports have priority to supply power which power devices are connected Legal value are low normal middle or high priority If the same power priority on the ports the lower port index the higher power priority Low Set to low prior
85. s a Web based interface for configuring and managing the Switch This interface allows you to access the switch using the Web browser of your choice This chapter describes how to use the switch s Web browser interface to con figure and manage the switch Logging on the switch To log on to the Switch 1 In your web browser specify the IP address of the switch Default IP address is 192 168 1 254 2 Enter the factory default admin to login on the Switch with no password Refer to the figure 3 1 Figure 3 1 2 https H 192 168 1 254 Login Windows Internet E E S 3 System Informat Type in Username and Password then click OK Username adroin Password dmin 3 3 Command Line Interface by Console or Telnet Mode based Command Hierarchy The Command Line Interface CLI groups all the commands in appropriate modes by the nature of the commands Examples of the CLI command modes are described below Each of the command modes supports specific switch s commands Layer 2 2 Management Switch Series 20 The CLI Command Modes table captures the command modes the prompts visible in that mode and the exit method from that mode Table 1 CLI Command Modes Command Mode Exit or Access Access Method Prompt Previous Mode This is the first level of access User Mode Perform basic COMMAND gt Enter Logout tasks and list nan system information Privileged From
86. s command is used to configure log server 1 log log server This command is used to configure log server 1 1 log log server name lt WORD gt add This command is used to specify log server name enter a name up to 12 characters add a log server IP address Format log log server name lt WORD gt add ipaddr word Mode Global Config 1 2 log log server name lt word gt delete This command is used to delete a log server Format log log server name lt WORD gt delete Mode Global Config 2 log logging target Layer 2 2 Management Switch Series 35 This command is used to configure log notification level 2 1 log logging target memory This command is used to specify memory log notify level Format log logging target memory enable disable Mode Global Config 2 2 log logging target flash This command is used to specify flash log notify level Format log logging target flash enable disable Mode Privileged Mode 2 3 log logging target console This command is used to specify console log notify level Format log logging target console enable disable Mode Global Config 2 4 log logging target server This command is used to specify console log notify level Format log logging target server name lt WORD gt enable disable Mode Global Config radius server This command is used to configure radius server Format radius server ip lt P addr gt Mode Global Config static address This command is used to specify static address
87. s command is used to displays dhcp snooping global configuration Format show dhcpsnooping config Mode Privileged Mode 27 2 show dhcpsnooping port This command is used to displays dhcp snooping trust port Format show dhcpsnooping port Mode Privileged Mode 27 3 show dhcpsnooping vlan This command is used to displays dhcp snooping vian Format show dhcpsnooping vian Mode Privileged Mode 27 4 show dhcpsnooping database This command is used to displays dhcp snooping database entries 27 4 1 show dhcpsnooping database all This command is used to show all dhcpsnooping entries Format show show dhcpsnooping database all Mode Privileged Mode 27 4 2 show dhcpsnooping database static This command is used to show all dhcpsnooping static entries Format show show dhcpsnooping database static Mode Privileged Mode Layer 2 2 Management Switch Series 31 27 4 3 show dhcpsnooping database dynamic This command is used to show all dhcpsnooping dynamic entries Format show show dhcpsnooping database dynamic Mode Privileged Mode 28 show ipsrcgd Note This command only supports on the following switches 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch This command is used to displays the cofig ports and database of the IP source Guard 28 1 show ipsrcgd config This command is used to displays the configuration of IP Source Guard Format show ipsrcgd config Mode Priv
88. seT with 2 shared Gigabit SFP Layer 2 Management Switch 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch 5 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch 1 dos land This command enables and disables land type attacks prevention Format dos land enable disable Mode Global Config 2 dos blat This command enables and disables blat type attack prevention Format dos blat enable disable Mode Global Config 3 dos syn fin This command enables and disables SYN fin type attack prevention Format dos syn fin enable disable Mode Global Config 4 dos ports 4 1 dos ports smurf This command enables and disables Smurf TYPR attack prevention Format dos ports smurf enable disable Mode Global Config 4 2 dos ports ping flooding This command enables and disables ping flooding type attack prevention Format dos ports ping flooding enable disable Layer 2 2 Management Switch Series 50 Mode Global Config 4 3 dos ports synack flooding This command enables and disables SYNACK flooding type attack prevention Set rate is 64 kbps or 128kbps for port lists 1 3 5 7 9 11 Format dos ports synack flooding enable disable rate 64 128 lt port list gt Mode Global Config e g Switch lt Config gt dos ports synack flooding enablerate 64 1 4 Switch lt Config gt dos ports synack flooding enablerate 64 5 tacplus 1 tacplus authen_type This command is used to set authenticati
89. seTX 2 Gigabit combo Layer 2 Management Switch The front panel of 24 Port 100BaseTX 2 Gigabit combo ports Layer 2 Management Switch has 24 10 100 Mbps copper ports at the left 2 10 100 1000 Mbps copper ports and 2 Gigabit SFP slots at the right The product name is at the top on the left Figure 2 2 2a shows a front panel of this switch The rear panel has a power connector and figure 2 2 2b shows a rear panel of the switch Table 2 2 2c shows the port function of the switch Figure 2 2 2a Front Panel M Port 10400BaseTx 2 Gigatit Combo ports Layer 2 Management Switch a z x 3 tees ee ree ene et a i eee j s 1 w Ce e Ta a ee ST TT Figure 2 2 2b Rear Panel Table 2 2 2c Port Function Port Function 24 This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2__ ethernet cable for 10 100 1000 Mbps ethernet connection 7 This is where you connect the SFP module for fiber miniGBIC i connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the AC power cord 2 2 3 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch The front panel of 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Slots Layer 2 Management Switch has 48 10 100 Mbps copper ports at the
90. snsressnsnssnnsnnnssensnsnnnnnnnennnnnnnnnnnnnnnnnnnennnnnnn 15 2 5 Installing the Switch sseessssnnneneeeeeeesnnrnnnnnnsseeenrnnnnrnnsserennnnnnnneeeet 15 2 6 Rack Mount Placement cccccceeeeseseeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 17 Configuratio i mss aiene a a Aa AE a a ESEA 19 3 1 Preparing for CONNQUIAUON Seek eee eee A ee ke A ee i td 19 3 2 Web based Configuration cccccceeceeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeeeee 20 3 3 Command Line Interface by Console or Telnet eeeeeee 20 SPCCIICATIONS tmnt onre a eie aae a e aae na e e aa aSa eae Eaa 61 Warranty statement ihesatsisectiathleahtanileshiupidaphivtbtusttutie abt thiuahivainnabtutbletl 85 Layer 2 2 Management Switch Series 3 1 Introduction Thank you for choosing Layer 2 2 series Management Switch These switches are cost effective switching solution idea for small business and the network edge It provides the Quality of Service QoS features like 802 1p DSCP and Rate Control etc to ensure the traffic is prioritized properly to deliver real time applications like voice and video and also have a good control in network bandwidth usage The 802 1Q feature enables you separate the network traffic easily and quickly The Network Security features like ACL Port Security Storm Control 802 1X and Management IP List etc enables you to prevent unauthorized access to company network and block intentional or inadvertent network traffic The Sp
91. t embedded with PoE PSE function Figure 2 2 7a shows a front panel of the switch The rear panel has a power and console connector and Figure 2 2 7b shows a rear panel of the switch Table 2 2 7c shows the port function of the switch Figure 2 2 7a Front Panel Figure 2 2 7b Rear Panel Power Layer 2 2 Management Switch Series 9 Table 2 2 7c Port Function Port Function This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2__ ethernet cable for 10 100 1000 Mbps ethernet 1 24 connection This is where you connect the SFP module for fiber miniGBIC i connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the DC power adapter 2 2 8 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch The front panel of 8 Port 10 100BaseTX 2 Gigabit Combo Layer 2 Management Switch has 8 10 100 Mbps copper ports at the left with 2 shared Gigabit SFP slots at the right The product name indicates at the top on the right Figure 2 2 8a shows a front panel of the switch The rear panel has a power and console connector and Figure 2 2 8b shows a rear panel of the switch Table 2 2 8c shows the port function of the switch Figure 2 2 8a Front Panel imaa 1 2 3 4 w wma GI cpe miniGBie 1 a hy ae om 8 Port 10 100BaseTx 2 Gigabit Combo ti
92. ter Format spanning tree max age lt 6 40 gt Mode Global Config 5 spanning tree max hops This command configure the number of hops in a region Format spanning tree max hops lt 1 40 gt Mode Global Config 6 spanning tree port 6 1 spanning tree port all This command specifies RSTP capability for all ports Format spanning tree port all enable disable Mode Global Config 6 2 spanning tree port cost This command configures RSTP port path cost Format spanning tree port cost lt 0 200000000 gt Mode Global Config 6 3 spanning tree port priority This command configures RSTP port priority Format spanning tree port priority lt 0 24 gt Mode Global Config 6 4 spanning tree port edge This command configures STP edge Format spanning tree port edge enable disable ports lt port list gt Mode Global Config 6 5 spanning tree port force p2plink This command configures force point to point link mode on ports Format spanning tree port force p2plink auto enable disable ports lt port list gt Mode Global Config 6 6 spanning tree port migration check This command Re checks the appropriate BPDU format to send on ports Format spanning tree port migration check enable disable ports lt port list gt Mode Global Config 6 7 spanning tree port root guard This command is used to configure stp root guard Format spanning tree port migration check enable disable ports lt port list gt Mode Global Config 7 spanning tree priority This
93. tering for controlling the set of multicast groups to which hosts on a switch port can belong Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports one to one or many to one Port Mirroring Supports IEEE 802 3ad Link Aggregation up to 3 aggregation groups Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high priority voice traffic on a port port basis Per port Ingress and Egress Rate Limiting Minimum rate is 64 Kbps granularity is 64 Kbps Supports Static Mode and Dynamic Learning Mode for Port Security function Support up to 24 MAC addresses for each port Layer 2 2 Management Switch Series 70 Supports Protected port feature Supports SSL SSH secure access Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast Known multicast and unknown unicast storm control Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X
94. time interval Format snip serve polling lt 0 9 gt Mode Global Config 4 sntp timezone This command sets sntp timezone Format sntp timezone lt 1 75 gt Mode Global Config spanning tree 1 spanning tree forceversion This command configures Spanning Tree protocol version 1 1 spanning tree forceversion 8021s This command selects spanning tree type as 8021 s multiple Spanning Tree Format spanning tree forceversion 8021s Mode Global Config 1 2 spanning tree forceversion 8021w This command selects spanning tree type as 802 1w rapid Spanning Tree Format spanning tree forceversion 8021w Mode Global Config 1 3 spanning tree forceversion none This command selects none spanning tree type Format spanning tree forceversion none Mode Global Config 2 spanning tree configuration This command configures MSTP region name and revision 2 1 spanning tree configuration name This command configures MSTP region name Max 32 chars Format spanning tree configuration name lt WORD gt Mode Global Config 2 2 spanning tree configuration revision This command configures revision level Format spanning trees configuration revision lt 0 65535 gt Mode Global Config Layer 2 2 Management Switch Series 44 3 spanning tree forward time This configures the bridge forward delay parameter Format spanning tree forward time lt 4 30 gt Mode Global Config 4 spanning tree max age This command configures the bridge max age parame
95. to 6 55Mpps wired speed L2 packet forwarding Jumbo Frame support up to 2048 bytes Provides Store and Forward switching mechanism Provides non blocking switching performance m Provides Multicasting Broadcasting and flooding Control m Supports packet filtering and port security Four egress queues on all switch ports Console port Male DTE Default setting 38400 8 N 1 Flexible TCAM based Compact Field Process for packet classification and filtering Layer 2 2 Management Switch Series 81 4 3 Environments Specification 1 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Size H x W x D 44 45 x 430 x 180mm Weight Net Gross 2 4kg 3 5kg 88 2 oz 123 5 oz Power 100 120 200 240 VAC 1 0 A 0 5 A 50 60Hz Operating Temp 0 C 40 C 32 F 104 F Storage Temp 40 C 70 C 40 F 158 F Operating Humidity 20 to 85 relative humidity non condensing Storage Humidity 20 to 90 relative humidity non condensing 2 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch 3 48 Port 1000BaseT with 4 shared Gigabit SFP Layer 2 Management Switch 4 24 Port 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch Size H x W x D 44 45 x 430 x 250mm Weight Net Gross 3 5kg 5 0kg 105 8 oz 141 oz Power 100 120 200 240 VAC 1 0 A 0 5 A 50 60Hz Operating Temp 0 C 40 C 32 F 104 F Storage Temp 40
96. tor s password to factory default Format clear pass Mode Privileged Mode 7 clear lacp This command is used to restore LAG and LACP configuration to factory default Format clear lacp Mode Privileged Mode Layer 2 2 Management Switch Series 23 8 clear logs This command is used to clear memory flash logs Format clear logs Mode Privileged Mode 9 clear vlan This command is used to delete all VLAN groups Format clear vlan Mode Privileged Mode configuration Enter into Global Configuration mode Format configuration Mode Privileged Mode copy This command is used to upload file from switch to host or download file to switch from host 1 copy nvram_config This command is used to backup switch configuration Format copy nvram_config tftp lt A B C D gt file lt filename gt Mode Privileged Mode e g Switch copy nvram_config tftp 192 168 1 100 file switch_configuration 2 copy system_image This command is used to backup switch runtime image Format copy system_image tftp lt A B C D gt lt filename gt Mode Privileged Mode e g Switch copy system_image tftp 192 168 1 100 image_file 3 copy tftp This command is used to download configuration or runtime image from host to switch Format copy tftp lt A B C D gt file lt filename gt nvram_config system_image Mode Privileged Mode e g Switch copy tftp 192 168 1 100 file switch_configuration nvram_config Switch copy tftp 192 168 1 100 file runtime_code syst
97. twork sysinfo syscontact lt WORD gt Mode Global Config 6 network admin timeout This command configures web console admin time out interval 0 means disable Format network admin timeout lt 0 65535 gt Mode Global Config port all 1 port all admin mode Layer 2 2 Management Switch Series 38 This command configures ports admin mode Format port all admin mode enable disable Mode Global Config 2 port all auto negotiate This command configures ports auto negotiation mode Format port all auto negotiate enable disable Mode Global Config 3 port all flow control This command configures ports flow control Format port all flow control enable disable Mode Global Config 4 port all portsec lockmode Configure port security 4 1 port all portsec lockmode none This command disable port security Format port all portsec lockmode none Mode Global Config 4 2 port all portsec lockmode static Note This commands only support on 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch amp 48 Port 100BaseTX 4 1000BaseT with 2 shared Gigabit SFP Layer 2 Management Switch models This command enable static lock mode Format port all portsec lockmode static Mode Global Config 4 3 port all portsec lockmode dynamic This command enable limited dynamic lock mode Format port all portsec lockmode dynamic max entries lt 0 24 gt Mode Global Config 5 port all rate limit Configure rate limit value on all
98. u connect the Cat 5e or better G1 G2__ ethernet cable for 10 100 1000 Mbps ethernet connection ni This is where you connect the SFP module for fiber miniGBIC connection Console This is where you connect the RS 232 cable for CLI management Power This is where you connect the AC power cord 2 2 10 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch Desktop The front panel of 24 Port 100BaseTX 2 Gigabit combo ports Layer 2 Layer 2 2 Management Switch Series 11 Management Switch has 24 10 100 Mbps copper ports at the left 2 10 100 1000 Mbps copper ports and 2 Gigabit SFP slots at the right The product name indicates at the top on the left Figure 2 2 10a shows a front panel of this switch The rear panel has a power connector and figure 2 2 10b shows a rear panel of the switch Table 2 2 10c shows the port function of the switch Figure 2 2 10a Front Panel a a aa aa a a aa a i a l tl FPPPFFFFEFFFFF E sna 13 u 15 16 7 18 9 20 z 2 E 2 we mee G2 S Figure 2 2 10b Rear Panel Table 2 2 10c Port Function Port Function This where you connect the Cat 3 5 5e or better ethernet cable for 10 100 Mbps ethernet connection This where you connect the Cat 5e or better G1 G2__ ethernet cable for 10 100 1000 Mbps ethernet 1 24 connection ini This is where you connect the SFP module for fiber miniGBIC k connection Console This is where you connect th
99. upports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports one to one or many to one Port Mirroring Supports IEEE 802 3ad Link Aggregation up to 3 aggregation groups Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high priority voice traffic on a port port basis Per port Ingress and Egress Rate Limiting Minimum rate is 64 Kbps granularity is 64 Kops Supports Static Mode and Dynamic Learning Mode for Port Security function Support up to 24 MAC addresses for each port Supports Protected port feature Supports SSL SSH secure access Supports 802 1X port based authentication and build in RADIUS client to co operate with the RADIUS servers Supports broadcast known multicast and unknown unicast storm control Layer 2 2 Management Switch Series 68 Supports web based interface for management Supports CLI interface for local console or remote Telnet management Supports TFTP HTTP and X modem protocol for firmware configuration upgrade or backup Supports DHCP Relay Supports IGMP
100. urce Guard Supports Green Ethernet Supports Auto Dos 8 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 8 PSE port embedded 100W PoE power budget 24 Port 100BaseTX 2 Gigabit combo Layer 2 Management Switch with 12 PSE port embedded 100W PoE power budget Four groups history statistics alarms and events of embedded remote monitoring RMON agents for network monitoring and traffic analysis Provides SNMP protocol v1 v2c v3 to monitor and control the switch by using SNMP management applications such as HP Open View IGMP snooping support to limit flooding of IP multicast traffic and filtering for controlling the set of multicast groups to which hosts on a switch port can belong Supports 802 1d 1w 1s Spanning Tree Protocol for loop free installation Supports 802 1Q VLAN for assigning users to VLAN associated with appropriate network resources traffic patterns and bandwidth Up to 256 VLAN entries can be configured Supports Management VLAN for administration to protect switch to be attacked by client Built in DHCP client to get IP address from DHCP server automatically Supports SNTP to synchronize the precision time with Internet Time server Supports one to one or many to one Port Mirroring Supports IEEE 802 3ad Link Aggregation up to 3 aggregation groups Supports for IEEE 802 1p DSCP CoS scheduling for classification and preferred high priority voice traffic on a port port basis Per port Ingress and E
101. witch on a hard flat surface with the front panel facing you Attach a rack mount bracket to one side of the Switch with the supplied screws Then attach the other bracket to the other side Figure 2 6 1 Figure 2 6 1 Make sure the brackets are properly attached to the Switch Use the appropriate screws not included to securely attach the brackets to your rack Figure 2 6 2 Figure 2 6 2 Layer 2 2 Management Switch Series 17 Layer 2 2 Management Switch Series 18 3 Configuration The configuration programs are supplied with these Layer 2 Management Switches Unlike the unmanaged switch dumb switch the switch performs management functions that make the switch operate more effectively This Chapter will describe the use of the switch Management Configuration program 3 1 Preparing for configuration Layer 2 Management Switch offers a console CLI interface for switch configuration and management Users can use this interface to perform the activities such as configuring DHCP ARP assigning IP address and upgrading firmware etc There are four methods to manage your switch Local Console Management You can manage the switch locally by connecting the switch to a PC or workstation with terminal emulation software using the serial port Remote Console Management You can manage the switch by having a remote host establish a Telnet connection to the switch via an Ethernet or mod

Download Pdf Manuals

image

Related Search

Related Contents

CP210113 Les perles de la Oumma  Basic DX - VMCare - With the greatest care for Care  Dexford WS 101  夏秋トマトの灌水同時施肥栽培における葉柄の硝酸濃度に応じた窒素追肥    Sony LCS-G1BP  Dell S2715H Monitor Outline Drawing  [U1.00.00] Prise en main de Code_Aster  Defort DCD-14N-DZK  Samsung WF8800APF/XEP Manual de Usuario  

Copyright © All rights reserved.
Failed to retrieve file