Home
ULTRAK 485 60 - Memory Version ULTRAK 493 300
Contents
1. RESISTANCE The stopwatch is designed to withstand accidental contact with water such as splashes or rain but it is not designed for use in water Do not operate the buttons when the stopwatch is wet TEMPERATURE Do not leave your stopwatch under direct sunlight or in very high temperatures for a long time the display may become black Do not leave your stopwatch in very low temperature as this may cause a slight time loss or gain and the change of digits becomes slow In both cases the above conditions will be corrected when the stopwatch returns to normal temperature SHOCKS Be careful not to drop your stopwatch or hit it against hard surfaces as it may cause a mechanical damage STATIC ELECTRICITY The integrated circuit in your stopwatch can be affected by static electricity If the static electricty is very strong a permanent damage can occur Be careful of the screen of the TV set and the wearing of clothing made of synthetic material in dry weather in such cases a very strong electricity can be generated MAGNETISM Not affected CHEMICALS Do not expose your stopwatch to solvents such as gasoline and alcohol spray of cosmetics cleaners paints etc as they may cause damage to the stopwatch BATTERY CHANGE When the display becomes dim or faded out battery replacement is necessary 1 Turn the battery cover off from close to open position by using the rope holder 2 Push the Battery Lock in the direction shown to rel
2. ULTRAK 485 60 Memory Version K ULTRAK 493 300 Memory Version C ULTRAK 494 EL Version OPERATING INSTRUSTIONS FEATURES SPECIAL MECHANICAL FEATURES Mechanical Lock for stop Button Battery Hatch back open by the rope holder RECALL CHRONOGRAPH Display of Lap split and running chronograph Measure up to 9 hours 59 minutes and 59 99 seconds 300 recallable lap and split memories for ULTRAK 493 and 494 60 memory for ULTRAK 485 display of fastest FS Slowest SL and average AV lap times for the laps traversed lap counter 00 999 Electro Luminescent backlighted LCD in ULTRAK 494 only TIMER Presettable countdown timer maximum 10 hours Automatically recycles upon completion of countdown and cycle counter to keep track of cycles counted 30 seconds shuttle countdown for timeout period timekeeping PACER Presettable from 10 beeps minute to 320 beeps minute Display of pacer frequency beep counter and total time elapsed simultaneously CLOCK Hour minutes seconds month date day and year auto calendar Alarm hour and minutes 12 24 hour and European calendar user option CHRONOGRAPH OPERATION Depress C to select the operating mode The chrono indicator is shown Depress A to start c3 c3 k g c3 ca e393 c3 c3 Remarks user may move the lever at the back of button A to n oo HHHH prevent accidental stop of the running chronograph nn uo Dee
3. an 30 seconds only 2 beeps will sound on approach of zero 2 When timer reaches zero while the stopwatch is in other modes only 2 beeps will sound Depress C to select the PACER mode The display will be as shown with the last 2 digits at the lower row blinking At this status depress B will sequence the PACER frequency as follows 10 20 30 40 60 80 120 160 240 320 Depress A to start PACER A beeping sound of 320 beeps minute will sound The total time elapsed will be shown on the top row the beep counter at the center and PACER frequency at the lower row The beep unter has a range of 9999 Depress A to stop PACER Remarks Pacer will be reset if the stopwatch is switched to another mode Depress C to select CLOCK mode The alarm hour alarm minutes month date day year hour minute and seconds are displayed as shown Time setting can be done by means of de pressing B to select digits and A to advance digits 3 Remarks alarm is automatically armed if alarm hour or minute has been set Alarm can also be armed or disarmed by depress ing C at normal time mode When alarm is armed AL is flashing and when not armed AL is not flashing When the alarm time is reached and the alarm is armed an output of 3 short beeps second will sound for 15 secnds Remarks if the alarm time is reached when the stopwatch is in other modes the alarm will only sound 3 short beeps CARE OF YOUR STOPWATCH WATER
4. ease the old battery push to lt release CR2032 Battery Lock 3 Install a fresh lithum battery CR2032 into the battery holder please make sure the Battery Lock is in the position shown 4 Re install the battery cover turn the dot from open to close position CALIFORNIA USA ONLY This Perchlorate warning applies only to primary CR Manganese Dioxide Lithium coin cells sold or distributed ONLY in California USA Perchlorate Material special handling may apply BK 151 1 See www dtsc ca gov hazardouswaste perchlorate www cel ultrak com Printed in China 4
5. es Remarks the stopwtch can recall the last lap and lap data entered before the memory capacity used up 2 TIMER OPERATION nnn nn iow ood nanan gu OUO mma LILII 3 595900 9 59 S832 HHH Lo LO a ca Par ec uo wo ca co EI ines bo 65 mAmnn LILII Dj a PACER OPERATION PACE Depress C to select the TIMER mode Depress B to select digits and A to set digit Digits will be advanced by 1 for every depress of A When the seconds digits are set depress B to complete the setting process The upper and middle row will show the same preset time The 4 digit counter at the lower row will remain at nn HH Depress A to start countdown The timer can be started or stopp ed by depressing A When the timer approaches zero an output of 2 short beeps seconds will sound for 15 seconds push of B C or D buttons will stop the sound The counter will advance by 1 and timer starts again immediately When the timer is at stopped the condition depress D will imme diately start a 30 seconds shuttle countdown for timeout time keeping Which is displayed at the top row At the end of the 30 seconds a beep will be generated and the displays will return to the original status Depress D while this countdown is in progress will terminate it immediately and the display return to its original status Countdown will resume when A is depressed Remarks 1 if the preset time is less th
6. g Depress B to read the 1st Lap time LAP is shown at the upper sito HEAD M22 row SPLIT is shown at the middle row and the RUNNING nn o595 CHRONO is shown at the bottom row Leis os ire 5 Depress B to display the 2nd Lap time The 2 digit in dot matrix SHON 2 8 pek format at the top left corner is the Lap counter 0 06 4233 ee CIC CI 65 5 ea ca m ue roM ue Lap SPLIT CHRONO RECALL RECALL RECALL enn ug E 2262 Depress A to stop counting Remarks make sure the button is unlocked before the operation Depress D to recall 1st Lap data memory can be recalled anytime when the chronograph is either running or stopped Depress D again to recall the 2nd Lap data Depress D again to recall the stopped time At any time during the RECALL mode Depress A will display the average AV Lap time of the Laps traversed Remarks if lap counter is gt 999 or either Lap aplit is grater than will be displayed Depress B will display the slowest SL Lap time of the Laps traversed Depress B will display the fastest FS Lap time of the laps traversed Repeated depression of B will display the fastest and slowest Lap times alternately Another depression of the C button will return the chrono to the stopped status Depression of C at any time during recall mode serves the same purpose Depress A to restart counting or B to reset all memori
Download Pdf Manuals
Related Search
Related Contents
LED PAR 36 IP65 - Flash Sunbeam Bedding SBCHPS User's Manual remote control interfaces for do5000 series digital Copyright © All rights reserved.
Failed to retrieve file