Contents

1. 1 Disconnect AC power 3 Use your insulated wrench to remove the positive lead from the positive terminal on the battery pack Figure 2 Remove positive lead from positive terminal on the battery pack 4 Reconnect AC power Figure 3 Reconnect AC power to the charger 5 Charger will conduct a self test of its LED indicators Figure 4 Charger LED indicator self test Youu Visit www youtube com deltaqtechnologies for instructional videos 6a For 11 seconds after the self test the charger will display its default charge profile Profiles 1 6 will display on the ammeter as well as on the bulk charge indicator Figure 5 Charge profile 1 on the ammeter 6b Charge profiles 7 and above will display on the bulk charge indicator If the charge profile number has two digits it will be displayed by one or more flashes a pause then one or more flashes e g 13 O w amp E Figure 6 Bulk charge indicator displays charge profiles 7 and above Select a new profile 7 Disconnect AC power see Figure 1 8 Reconnect AC power see Figure 3 9 Touch the positive lead to the positive terminal for three seconds 0 5 seconds then remove the lead You will see the next profile displayed on the charger s display Repeat this step until you reach the desired charge profile am Figure 7 Touch the positive lead to the positive battery terminal for 3 secon
2. damaged or if the charger has received a sharp blow been dropped or is damaged in any way refer all repair work to the manufacturer or qualified personnel This charger is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge on electrical systems and battery charging unless they have been given supervision or instruction concerning use of the charger by a person responsible for their safety Children should be supervised to ensure that they do not play with the charger Maintenance Instructions Q A Attention Utiliser le chargeur seulement avec un algorithme appropri au type sp cifique de batterie D autres types de batteries pourraient clater et causer des blessures ou dommages Les batteries peuvent produire des gaz explosifs en service normal Ne jamais fumer pr s de la batterie et viter toute tincelle ou flamme nue a proximit des batteries Fournissez une ventilation ad quate du chargement Ne jamais charger une batterie gel e Prendre connaissance des mesures de pr caution sp cifi es par le fabricant de la batterie p ex v rifier sil faut enlever les bouchons des cellules lors du chargement et les taux de chargement A Danger Risque de d charge lectrique Ne pas toucher les parties non isol es du connecteur de sortie ou les bornes non isol es de la batterie Toujours connecter le chargeur a une prise de c
3. flashing Output Charge Completion Indicator Green Light has been reduced due to high internal charger temperature Displays charge profiles 1 6 for 11 seconds if no battery is connected AC Indicator Troubleshooting Instructions If a fault occurs count the number of red flashes between pauses and refer to the table below Battery high voltage Battery low voltage Charge timeout caused by battery pack not reaching required voltage or charger output reduced due to high temperatures Battery could not be trickle Charger shutdown due to high internal temperature 10 40 00 0 0 D Internal charger fault charged up to minimum voltage If solid Charging complete and maintenance mode is active If flashing Absorption phase complete in finishing phase If solid AC power is present If flashing Low AC voltage Check electrical source and cord length Fault Indicator Red Light Charger error Refer to troubleshooting information below Check battery size and condition This fault will clear automatically once the condition has been corrected Check battery size and condition This fault will clear automatically once the condition has been corrected Check connections that battery type matches selected charge profile and operate the charger at a lower ambient temperature Reset the charger by interrupting AC power for 15 seconds Check for shorted or damaged cells Reset the charger by i
4. QuiQ 1 kW Industrial Battery Charger Product Manual This manual contains important safety and operating instructions for standard Delta Q QuiQ chargers Please read this information in its entirety before using your QuiQ Charger For technical support please visit delta q com support or contact the manufacturer of your vehicle or machine as their versions of this charger may require special instructions A Warning Use charger only with an algorithm selected that is appropriate to the specific battery type Other usage may cause personal injury and damage Lead acid batteries may generate explosive hydrogen gas during normal operation Keep sparks flames and smoking materials away from batteries Provide adequate ventilation during charging Never charge a frozen battery Study all battery manufacturers specific precautions e g maximum charge rates and if cell caps should be removed while charging A Danger Risk of electric shock Connect charger power cord to an outlet that has been properly installed and grounded in accordance with all local codes and ordinances A grounded outlet is required to reduce risk of electric shock do not use ground adapters or modify plug Do not touch uninsulated portions of output connector or uninsulated battery terminals Disconnect the AC supply before making or breaking the connections to the battery Do not open or disassemble charger Do not operate this charger if the AC supply cord is
5. ds 10 When the charger displays the desired charge profile apply the positive lead to the positive battery terminal for 10 seconds When the charge profile is locked you will hear a click from the charger See Figure 7 for how to apply the positive lead to the positive terminal 11 Disconnect AC power wait for the LED indicator display to turn off then reconnect AC power See Figure 3 12 Check the LED display to ensure that the desired charge profile is selected 13 Disconnect the charger from AC power and wait for the LED indicator display to turn off See Figure 1 14 Reconnect the positive lead to the positive battery terminal Figure 8 Reattach the positive lead to the positive terminal after disconnecting AC power
6. nterrupting AC power for 15 seconds Ensure sufficient cooling airflow Reset the charger by interrupting AC power for 15 seconds Reset the charger by interrupting AC power for 15 seconds Return to service depot if fault persists Note This is a Class A product complying with United States Federal Communications Commission Code of Federal Regulations 47CFR part 15 In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WARNING Charger connectors must be mated to connectors from the same manufacturer Failure to do so may void warranty and cause a hazardous condition or equipment damage Q www delta q com Selecting A Charge Profile Delta Q QuiQ Charger Manual Delta Q s QuiQ Charger can store up to 10 charging profiles also called charge algorithms This section shows how to identify the default profile and select a new profile using the tap method QuiQ chargers are reprogrammable using the QuiQ Programmer supplied by Delta Q to its OEM partners Pre 2006 QuiQ chargers with serial number prefix DQCP allow pre loaded profiles to be selected but cannot be reprogrammed with new profiles Identify the default profile 1 Required supplies include an insulated wrench eye protection and gloves 2 Disconnect the AC power source from the charger either from the wall outlet or from the IEC320 connector on the charger Figure
7. oper cord set terminating in an attachment plug of the proper configuration for the power outlet North America UL or CSA listed approved detachable cord 3 conductor 16AWG minimum and rated SJT terminated in a grounding type IEC 60320 C14 plug rated 250V 13A minimum For all other regions Safety approved detachable cord 3 conductor 1 5mm minimum rated appropriately for industrial use The cord set must be terminated on one end with a grounding type input connector appropriate for use in the country of destination and on the other end an output grounding type IEC 60320 C14 plug 2014 Delta Q Technologies Corp All rights reserved PN 710 0171 Rev 1 Date 12 09 2014 Operating Instructions Delta Q QuiQ Charger Manual The charger may become hot during charging Use hand protection to safely handle the charger during charging Extension cords must be 3 wire cord no longer than 30m 100 at 10 AWG or 7 5m 25 at 16 AWG per UL guidelines Only connect one QuiQ Charger to a single 120VAC 15A circuit or the circuit may become overloaded The charger will conduct a self test after being powered on visible by flashing all of its LEDs in sequence Bulk Charge Indicator Ammeter If solid Bulk charge phase complete 80 charged in absorption phase If solid Displays f flashing Displays charge profile number if no battery is connected scale of output Displays charge profiles 7 and above during bulk phase If
8. ourant mise ala terre D connectez la source AC avant de faire ou d faire les connections a la batterie en chargement Ne pas utiliser le chargeur si le cordon d alimentation AC est endommag ou si le chargeur est abim suite a une chute ou autre indicent Ne pas ouvrir ni d sassembler le chargeur r f rer toute r paration aux personnes qualifi es Cet appareil n est pas destin a un usage par des personnes dont les enfants avec des facult s motrices sensorielles ou mentales r duites ou ayant une exp rience et des connaissances insuffisantes a moins qu elles sont sous la supervision ou re oivent les instructions sur l utilisation de l appareil d un r pondant garant de leur s curit Les enfants devraient tre surveill s afin qu il ne jouent en aucun temps avec l appareil 1 Do not expose charger to high pressure water spray when cleaning vehicle 2 The enclosure of the charger meets IP66 making it dust tight and protected against powerful water jets The AC connection is rated to IP20 which is not protected against water Protect the AC connection if used in wet or dusty environments 3 Ifthe detachable input power supply cord set is damaged replace with a cord that is appropriate for your region This charger is provided with a cord set for connection to outlets operating at nominal 120 Volts or 240 Volts as appropriate If the input plug does not fit the power outlet contact Delta Q Technologies for the pr