Home

User Manual

image

Contents

1. SMT374 d Place the SMT381 on top of the SMT338 VP Make sure that both modules fit firmly e Fit two M2 nuts on the Nylon screws and two M3x4 screws in the 3 3V pillars 3 Connect CommPort 1 of the SMT395 VP to CommPort 3 of the SM7338 VP T1C1 to T2C3 via an FMS cable at the back of the SM 7310Q Also make the connection T1C2 to T3C3 Version 1 3 Page 11 of 16 SMT8101 User Manual 4 Connect SHBA on the SM7395 VP to SHBA on the SM 1338 VP via the SM7T516 5 Connect SHBB on the SM1395 VP to SHBB on the SM1338 VP via the SMT511 SHB to SHB cable 6 Connect J2 and J3 SMT381 VP to an oscilloscope or other system of display via MMBX BNC cables 7 Place the carrier board in the host system and power up the PC and a fan to cool down the system 8 Connect a signal 0 36 Volts peak to peak to J1 and J2 SMT391 VP The following pictures show how connections are made at the top of the system Figure 2 the cable connections of the SMT8101 system Version 1 3 Page 12 of 16 SMT8101 User Manual The following picture shows the CommPort connection at the back of the SMT310Q Note that the FMS are twisted i e one end should be blue and the other should show silver pins T1C1 to T2C3 and T1C2 to T3C3 Figure 3 comport connections Version 1 3 Page 13 of 16 SMT8101 User Manual Hardware Connections Below are listed the connection to be checked before plugging the system in the PC
2. FMS connections 1101 to T2C3 1102 to T3C3 SHB connections SMT395 VP SHBA to SM7T391 VP SHBB using SMT516 SMT395 VP SHBB to SM7T391 VP SHBA using SMT511 RSL connections SMT391 VP RSLA to SM7T381 VP RSLB using SMT526 SMT391 VP RSLB to SM7T381 VP RSLA using SMT522 Clock Connection Use an MMBX to MMBxX cable to link J8 SM7T391 VP to J5 SM1T381 VP This is to pass the 1GHz clock to the DAC module Version 1 3 Page 14 of 16 SMT8101 User Manual Software applications 3L application In a sub folder labelled 3L directory SMT6600 Systems SMT8101 you will find a C SMT8101 c a configuration SM7T8101 cfg and a make nmake files In a DOS prompt window simply type nmake to generate the 3L application file which can be loaded into the SM I395 VP30 by using the 3L Server 3L Diamond needs to be installed first This application allows the user to execute simple commands such as configuring the ADC output format and scale the clock synthesizers clock routing capturing data jelcome to the SHTS101 Domo Application lente select the requested action Configure the FPGA of the S4T391 UP Should be done before starting the Configure the FPGA oF the SHT3S1 UP Retrieve Configuration of both FPGAS Start the SHT391 UP Start the SHT3e1 UP Capture date on host 3 Exit A Emar T Echo mirin ii iu Description of the functions in the test software menu
3. ATE AE OE OA 14 SL APPICAUO M aane E E EE oe ee aise T A 14 Description of the functions in the test Software MenU ccccceseceeeeeeeeeeeeeeeeees 14 Configure the FPGA of the SMT381 VP aannnnannnennnnnnnnennnnnnnnennnnnnnnnrrnnnennnnnnne 14 Retrieve configuration of both FPGAS cccsccccseeeeseeeeseeeeseeeesseeeseeeeseeesaes 14 Stante SMTS91V P uainn 15 SA ME SMBS TVP onanan 15 Capture Data ON HOS Tosia AE 15 What is provided in the SMT8101 system cccccccccsecceceeeeeeeeeeseeeeesaeeeesaeeeesaeeeeas 16 Table of figures Figure 1 top view of the SMT8 TOT aeria 11 Figure 2 the cable connections of the SMT8101 system ccccccceeeeseeeeeeeeeeeees 11 FOUE S COMPOR CONNECCION S isigocies cceteded teaches ek hae eee ee 12 Version 1 3 Page 4 of 16 SMT8101 User Manual Contacting Sundance You can contact Sundance for additional information by sending email to support sundance com Notes SHB stands for Sundance High speed Bus RSL stands for Rocket Serial Link Comport denotes an 8 bit communication port following the TI C4x standards SMT8101 is a PCI system to be plugged in a PC The only software requirement is to have 3L Diamond server installed Precautions In order to guarantee that Sundance s boards function correctly and to protect the module from damage the following precautions should be taken They are static sensitive products and should be han
4. SUNDANCE SMT8101 User Manual Version 1 3 Page 2 of 16 SMT8101 User Manual Revision History Date Comments Engineer Version 20 05 2005 Original Document PSR 23 08 2005 More exhaustive description of connections PSR 1 1 added 14 09 2005 Parts list added block diagram corrected PSR 1 2 photo 3L application added 20 10 2005 Updated pictures of the system JPA 1 3 Added table of figures Version 1 3 Page 3 of 16 SMT8101 User Manual Table of contents REVISION TISIONY jecessaus seas eenansianssaseaatiareie ive vine edee ins eduelieseivetiveiverdeieiveaeseie eee eri 2 TDC Of GOMTEMIS anrr AE eatin eee eae aes aS es Sneak 3 Bro aire ell gle Wey o 10 E 1a e Perma E ete tet i ere ne er ie cee Mee Me ee ee E oe 4 INGOTS Sis scp 208 E ETA EAE gue saa eats a 4 ee 21612 10 0 cen re ete seven pene Drees eer Ger ete a De tee een een one mne nr ee ont remote ree 4 OUTING GESCHDNO I eed tenses esansnsetasensdadasnabuaensbedasemer becebivsnieaticneseievbesuerbeeceeaty 5 Main Modules description cccccccccseccceeecceeecuceceuceceuceceuseceuseseuseseusessusesueessueessnees 5 PAC Mie GLUING s watecdiareatsceaounccuacgubacaatisensaesananataeisaudae usando sasasanndaseaaianmagecaanh een eaeae tee 7 PIELAWANS INSIANAUOM s ssicsnecandeanstenusanetendsannGanuvanetanduasetenstanedanauanetanausvetanaeanetaneennetandcente 9 Hardwale GONMECHONS earan a A A E uate caieueieunieee 13 SONWare APPICAUONS eraris aa E nated
5. The 3L application provided with the system allows the following option Some will prompt for a value Configure the FPGA of the SMT391 VP This command is used to reprogram the SMT338 VP second TIM site SMT391 VP FPGA with a different new bitstream Configure the FPGA of the SMT381 VP This command is used to reprogram the second SMT338 VP second TIM site SMT381 VP FPGA with a different new bitstream Retrieve configuration of both FPGAs This command is used once the FPGAs have already been configured and a reset has occurred It sends an END KEY please refer to SMT338 VP User Guide to retrieve the FPGA configurations previously loaded Version 1 3 Page 15 of 16 SMT8101 User Manual This command MUST be executed before using the system Start the SM1391 VP This command sends all setting necessary to the SMT391 VP Start the SM1T381 VP This command sends all setting necessary to the SW7381 VP Capture Data on HOST This command captures data from both SHBs coming from ADCs and stores them into files Version 1 3 Page 16 of 16 SMT8101 User Manual What is provided in the SM7T8101 system When purchasing an SMT8101 system you will get the following unless stated on order invoice OMT395 VP30 6 SMT310Q SMT381 VP30 6 SMT338 VP30 6 and SMT381 SMT391 VP30 6 SMT338 VP30 6 and SMT391 Note that the SMT391 needs to be modified in order to pass its on board VCO c
6. bidirectional such as the temperature monitoring of both DAQ modules SMT391 VP and SMT381 VP or to capture blocks of data via the SHB Bus SMT511 and SM1516 to the DSP Version 1 3 Page 9 of 16 SMT8101 User Manual Hardware installation Here are the basic steps to follow to install an SLB module with its mezzanine As an example the SMT381 VP the SMT391 VP follows the same procedure which is the combination of the SM1338 VP30 6 SLB Base Module and the SMT381 Mezzanine Module Please note that photographs dont necessarily match exactly with the SMT8101 systems but refer to similar products 1 Place the SMT395 VP on TIM site 1 of the carrier board SM7T310Q 2 The following are then required to mount SM1338 VP30 64 SMT381 on the SMT310Q HERR 3 UU O z Holes mounted with Nylon screw M2x10 and 4 Nylon nuts M2 SMT338 VP SMT381 Holes mounted with Nylon screw M2x10 and 4 Nylon nuts M2 TIM 3 3V a First fit two Nylon screws M2x10 pointing out the head of the screws on bottom side Version 1 3 Page 10 of 16 SMT8101 User Manual b Then fit four M2 nuts on each screw Maxid 42M Nuta c Place the SM1338 VP on the second site SM I395 VP already on first site on the SM7T310Q and fit two metal pillars 3 3 Volts e I IUO so eT i a F i men SMT338VP i 1 kK F POOOAIROOLOO ETU OOU OUOU O NOTOU OTOT nne ean
7. dled accordingly Always place the modules in a static protective bag during storage and transition When operated in a closed environment make sure that the heat generated by the system is extracted e g a fan extracting heat or blowing cool air Sundance recommends and uses PAPST 12 Volt fans Series 8300 producing an air flow of 54 cubic meters per hour equivalent to 31 8 CFM Fans are placed so they blow across the PCI bus Version 1 3 Page 5 of 16 SMT8101 User Manual Outline description The SMT8107 is PCI based and stands as an evaluation development platform for Multi carrier Multi standard cellular systems High Direct IF infrastructures Test Equipment etc This system is built around 4 main boards C64xx based module SM1I395 VP combined with a dual channel high speed ADC module SM 391 VP and a dual channel high speed DAC SMI381 VP all plugged on a PCI carrier board SMT310Q Main Modules description Three modules are described below For more details please refer to www sundance com SM1T395 VP characteristics gt TMS320C6416T processor running at 1GHz Virtex Il Pro FPGA gt 8MByte Flash ROM for boot code and FPGA programming 256MB of SDRAM 133MHz gt Global expansion connector Six 20MB s communication ports comports High bandwidth data I O via 2 Sundance High speed Buses SHB Eight 2 5Gbit sec Rocket Serial Links RSL SM1T381 VP characteristics Dual channel 14 bit DAC Fujit
8. lock to the SMT381 Two FMS cable SMT502 SMT516 SHB PCB SMT511 320 SHB Cable 320mm long SMT520 04 MMBX to BNC cables SMT509 100 100mm MMBX to MMBX to feed the SMT391 on board VCO clock to the SMT381 SMT526 RSL IC1 RSL PCB SMT522 RSL10 RSL flexi cable 10 inches long
9. nnection Connection SMT310Q SMT395 SMT391 VP SMT381 VP 1 GHz DSP 1 GHz ADC 1 GHz DAC Spare Module Module Module Module 1 Module 2 Module 3 TIM site 1 TIM site 2 TIM site 3 TIM site 4 Control and Configuration Comports PC Host The SMT395 VP is the module that controls all operations of the system starting from configuring SMT391 VP and SMT381 VP FPGAs Xilinx Virtex Il Pro VP30 6 using configuration ports Comports The data path is clearly as follows Analog inputs are fed into the ADC module that converts it into digital samples The data flow is then passed onto the DAC module via RSL links 2 5 Gbits s SMT526 and SMT522 that transforms into Analog signals Data streams go through 2 FPGAs where processing can be added Samples are originally coded on 8 bits by the ADCs sent over the RSLs and converted into a 14 bit format samples to match the DAC data input as follow Sample_DAC_14_bits Sample_ADC_ amp _bit amp 100000 The SMT391 VP has an on board VCO that is used to generate a 1GHz clock which is passed to the SMT381 VP so ADC and DAC channels are receiving the same Version 1 3 Page 8 of 16 SMT8101 User Manual sampling clock It also makes the system stand alone with ADC and DAC channels synchronised As SMT381 VP and SMT391 VP have both Virtex Il Pro FPGAs XC2VP30 6 processing can be added on the way The DSP can also be report information through Comports
10. su MB86064 sampling at 1GHz gt Xilinx Virtex ll FPGA XC2VP30 6 gt Low jitter on board system clock gt Two 20MB s communication ports comports High bandwidth data I O via 2 Sundance High speed Buses SHB gt Eight 2 5Gbit sec Rocket Serial Links RSL gt Low jitter on board system clock Version 1 3 Page 6 of 16 SMT8101 User Manual gt 50 Ohm terminated analogue outputs via MMBX Huber and Suhner connectors gt External Triggers and Clocks via MMBX SM1T391 VP characteristics gt Dual channel 8 bit ADC Atmel AT84AD001 sampling at 1GHz gt Xilinx Virtex ll FPGA XC2VP30 6 gt Low jitter on board system clock gt Two 20MB s communication ports comports High bandwidth data I O via 2 Sundance High speed Buses SHB gt Eight 2 5Gbit sec Rocket Serial Links RSL gt Low jitter on board system clock gt 50 Ohm terminated analogue inputs via MMBX Huber and Suhner conneciors gt External Triggers and Clocks via MMBX Documentation and source files are installed by the way of the SMT6600 package which is the Sundance DAQ package Source and application files provided are to be run by the way of 3L Diamond Server only Version 1 3 Page 7 of 16 SMT8101 User Manual Architecture The following diagram shows the architecture of the SMT8101 system lt gt e i Analogue Data Data Control Data Data RSL Link Connection Global Bus SHB Comport SDB Comport 2 5Gbits s Connection Co