Contents

1. 14 3 Example GROUP Lgh OF MAX 10 DEVICE TYPEID 1003 SELECT ALL SORT BY Id TERATOR TempUpdate ALIAS Temp CHANNEL 1 Outdoor temperature SensAlarm TempSensor Channel for alarm out BEGIN Outdoor Temp IF SensAlarm THEN Outdoor 40 ENDIF IF sbTemp gt 3 THEN Boiler 0 ELSE Boiler 1 ENDIF END END This example is based on the device type used as example of DEVICETYPE in section 13 3 The device is a control central for apartment heating with electrical radiators One channel and one alarm is aliased The channel measures the outdoor temperature The alarm is an alarm monitoring the outdoor temperature sensor All parameter public and private variables in the device definition are also in scope The first row after begin assigns the outdoor temperature to a device variable This variable is used in a telegram question compiler not part of the example This mean that the outdoor temperature will be sent to all connected heating centrals If the alarm says the sensor is broken the devices will be told it is 40 degrees outside as this is better than any faulty reading like 150 The second if statements turns on and of a tap water boiler depending on the setback temperature sbTemp is a device parameter and represents how much the room temperature in the apartment
2. Name Type Comment Parameter Name String 20 A name p2200 TypID word Device type ID p2201 EMAILDEVICETYPEIDTEXT String Device type name p2202 EMAILDEVICEMAXDEVICES int Number of devices of p2203 defined type SendInterval long int p2204 SendStartTime long int p2205 SendTime long int p2206 Rcpt String 47 Array of four email p2208 array recipients Flags word Flag array p2291 9 6 WMShare parameters WMShare type definitions Name Type Comment Parameter Name String 20 A name p2300 Key String array Key strings p2301 Flags word Flag array p2391 Server urls Name Type Comment Parameter Server String 47 Array of four WMShare p2301 array server URLs Export Name Type Comment Parameter SHARESELFKEY String array Key strings p2321 SHARESELFCHNNR byte array Channel numbers p2322 Abelko Innovation 40 WebMaster Pro WMPro Reference Manual 10 The Script Language END Abelko Innovation 41 WebMaster Pro WMPro Reference Manual 70 7 Introduction The WMPro runs on script It can do a few things like measuring and manage alarms without scripts but certainly not work as a controller Normally you do not see the scripts You see the Controllers applet and the graphical programming tool In the background they generate scripts and it is these scripts that make the WMPro work as instructed This and the following chapters will reveal the secrets of
3. 4 Tm UII LIMIT 2 IL i Abelko 4435 83 DAT 050502 x abelko 4435 03 D T 050502 Document title WMPro Reference Manual 190901077 emer i 5 at Document Identity 4655 002 007 Date 2015 10 22 Valid for Firmare version Webpages version IMSE WebMaster Pro R4 0 2 42 3 19 Abelko Innovation info abelko se tfn 0920 22 03 60 zb P inno Ah ADE WebMaster Pro WMPro Reference Manual All information in this reference manual is believed to be correct and the manual is released as an aid to all WMPro users free of charge Abelko cannot guarantee that there are no mistakes or faults in this documentation and cannot be held responsible for any consequences that result from use or misuse of the enclosed information All information in this document can be changed without notice Some information is likely to change in future releases of the firmware Make sure you have the latest version of this document and that it is valid for your version of WMPro Copyright Abelko Innovation All rights reserved Abelko Innovation WebMaster Pro WMPro Reference Manual 1 2 GoP Wh o Doo 2 1 I
4. Abelko Innovation WebMaster Pro WMPro Reference Manual 16 WMShare Scripts 16 1 Introduction WMsShare lets WMPro import values from another WMPro as an external device The information is transferred using http As for the other types of external devices also WMShare requires type definitions Unlike the other types though WMShare types are normally defined by the user in web pages It is however also possible to define WMShare types in the script language 16 2 WMShare type definitions As WMShare devices can only retrieve information and never send data the type definition is quite different from GFBI and AeACom device definitions There are no frame interpreters or frame compilers The type definition is simply another way to fill in the web page form of a definition wmsharedevtype The TYPEID number must be between 1 and 5 The number of keys is limited to 20 If there is WMShare type definition present in the script it will overwrite any previous settings at start up A script defined WMShare type definition will be marked with blue background in the web page The user can still modify it but the modifications will be nullified on reboot IMSHAREDEVICE WMSTest NAMED WMSTest TYPEID 1 S KEY Outdoor OUTDOOR END In Release 2 0 there is no support for group scripts for WMShare devices Abelko Innovation 86 WebMaster Pro WMPr
5. These are Name Value Index Index in the group members list Starts at one and ends at Count Count The number of members in the group Status Device status 0 OK 1 FAILED 2 TRYING First One during the first execution of an iterator when Index is one Else zero Last One during the last execution of an iterator when Index Count Else zero DevIndex The index in the external devices list for the device the iterator is currently operating on Abelko Innovation 78 WebMaster Pro WMPro Reference Manual iterator expresions parameter identifier public identifier private identifier The iterators are not automatically executed as routines are in user scripts They must be called from a routine ROUTINE Application BEGIN CALL Lgh TempUpdate END If the group has no members the iterator will not be executed at all In release 2 1 two special statements unique to iterators were introduced iterator statements E SILENCE These allow the script to exercise more direct control over when telegrams sent Normally each telegram is sent regularly according to the telegram setting The SEND and SILENCE keyword can override the telegram setting SEND marks the telegram as ready to send This causes the telegram to be compiled and then sent with a delay of a few seconds SILENCE sets the telegram timer to infinity so th
6. Diff Diff as in differentiator or difference calculates the difference between the current value and the last value The difference is multiplied with the factor parameter MathParl MathPar2 Factor MathPar3 code Chn MathPar3 i Chn Value i Chn Value i Chn MathPar3 i Chn MathParl i Chn MathPar2 i Chn MathParl i Chn MathPar3 i Min Min looks and holds the lowest value found in a time period The value is updated every second If the interval parameter is zero it is reset every time it is stored in a database Otherwise the value is reset every Interval seconds MathParl MathPar2 Interval MathPar3 code if Chn MathPar3 i 0 Chn MathParl i Chn Value i reset if Chn Value i Chn MathParl i Chn MathParl i Chn Value i Chn MathPar3 i Chn MathPar3 i 1 if Chn MathPar2 i gt 0 if Chn MathPar3 i gt Chn MathPar2 i Chn MathParl i Chn Value i Chn MathPar3 i 0 else if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath Chn Value i Chn MathParl i Abelko Innovation 19 WebMaster Pro WMPro Reference Manual Max Max looks and holds the higest value found in a time period The value is updated every second If the interval parameter is zero it is reset every time it is stored in a database Otherwise the value is reset every Interva
7. If the expression after IF keyword is evaluated to a nonzero value it is considered true and the statements after THEN will be executed If it is zero the next ELSIF will be tried If no IF or ELSIF expression is nonzero the ELSE statements will be executed 1f it exists ROUTINE IfExamples ALIAS Temp CHANNEL 1 Valve CHANNEL 25 Force PARAMETER 1 FValue PARAMETER 2 Warning CHANNEL 50 BEGIN IF Temp gt 95 THEN Warning lt 1 ELSE Warning 0 ENDIF IF Temp gt 80 THEN Valve lt 100 ELSIF Temp gt 60 THI Valve lt 60 ELSIF Temp gt 40 THI Valve lt 20 ELSE Valve 0 ENDIF zi z zi z IF Force THEN Valve FValue ENDIF D Z Abelko Innovation 48 WebMaster Pro WMPro Reference Manual 11 2 3 Reset statements The reset statement is used to reset the mathematical function of a channel that is not reset by database updates Se the chapter on channels for information on which mathematical functions need reset reset_statement pase 11 2 4 Print statements The print statement is a debug utility that enables trace printouts during execution The string and the value of the expression are printed to the debu
8. o 3 S 5 4 9 4 3i T 0 2 g ok _ 0 10 20 30 40 50 60 5 MathPar1 Filter factor a value between 0 and 1 MathPar2 MathPar3 code float ffact Chn MathParl i if ffact gt 1 ffact 1 Chn MathParl i Chn Value i Chn Value i ffact Chn MathPar2 i 1 ffact Chn Value i Chn MathPar2 i Chn Value i Count over Counts every second the channel value is higher than the limit 1 Limit MathPar2 MathPar3 code if Chn Value i gt Chn MathParl i Chn MathPar3 i Chn MathPar3 i 1 Chn Value i Chn MathPar3 i Count under Counts every second the channel value is lower than the limit MathPar1 Limit MathPar2 MathPar3 Abelko Innovation 14 WebMaster Pro WMPro Reference Manual code if Chn Value i lt Chn MathParl i Chn MathPar3 i Chn MathPar3 i 1 Chn Value i Chn MathPar3 i Count pulse Counts the number of times he channel value changes from under the limit to higher than the limit This mathematichal function is not to be confused with the hardware supported counter functions on to DI4 MathPar1 Limit MathPar2 MathPar3 code if Chn Value i gt Chn MathParl i amp Chn MathPar2 i 0 Chn MathPar3 i Chn MathPar3 i 1 Chn MathPar2 i 1 else if Chn Value i lt Ch
9. neen rennen 105 Flag selectionfilter ecu RR 105 inn vices PR edet per riter RR quete tee 106 ZEST Ihe Used fl g inte o er eR rete EUER RR 107 2 6 The Edited flag x oa t e e d RE RP RR e REIR Pe ERR RE 107 2 16 The Script flag 15 e o rp RE Oe e 107 The SHOW flags aee e P ET REP 107 z Oo The BACKUP SIGS e a e ERR EE ER E E DU Fe ER UR E e ete exit 107 Tie other flags ue i ceret dH EEG Ee co tree E e deep heey 107 BACKUP PAR AND 108 The parameter bank edit interface esee nne eene 108 The Appinit ini file 5 iiti ee pti eoe CO ERR EH PG beets o ee OE RTE ETBE IERI recs 109 NAMING RESTRICTIONS oreet RIO Kette RIO YR Wee Ure PETERE V 109 SYSTEM PARAMETERS eene PEPERIT TER REED ERI 110 COMMAND PARAMETER 112 Abelko Innovation 6 WebMaster Pro 8WMPro Reference Manual 1 Introduction Welcome to the WMPro reference manual This document tries to compile all the information about the WMPro that did not fit into the user manual Where the users manual had the ambition to be a pedagogic and readable piece of literature the reference manuals main goal is make information about obscure details available in a way where it can be found The reference manual has three main sections The first
10. 4 Alarms 4 1 Introduction Alarms are an important functionality in WMPro Each alarm monitors one and only one channel When the set alarm criterion is met the alarm is triggered As alarms are well described in the user manual the reference manual will only address some details that are not fully described in user manual 4 2 Definition Name Type Comment Parameter Name String 20 A name 1100 Message String 128 Alarm message 1101 Reset byte Alarm reset p1102 TrigChnNr byte The number of the monitored p1103 channel TrigCond byte Alarm Condition type p1104 TrigLimit1 float Alarm trig limit p1105 TrigLimit2 float Alarm trig limit p1106 TrigHysteresis float Alarm hysteresis p1107 TrigFilterOn Int On filter p1108 TrigFilterOff Int Off filter p1109 TrigFilterCounter Int Filter counter p1110 Action Byte bitmask Action type 1111 ActionChnNr byte Action channel number 1112 Status byte Active or not 1113 ExpectAck byte Waiting for ack or not 1114 Long int Timestamp 1115 Flags word Flag array 1116 String 20 A name 1100 4 3 Alarm conditions The values of TrigCond have the following meaning Value Name Condition 0 OVER Channel gt TrigLim1 1 UNDER Channel lt TrigLim1 2 BIGGER ABS Channel gt TrigLim1 ABS stands for absolute value 3 SMALLER ABS Channel lt TrigLim1 Abelko Inno
11. J gt maer o 5 4 mme showers eres ern peers ME n o Unknowns are devices of a type the master has no information about These can either be accepted and assigned a time segment or rejected and told to shut up 15 3 AeACom Type Definitions Type definitions for AeACom is similar to those for GFBI For AeACom there are no telegrams in the GFBI sense Instead the device will send a message frame The length of this frame is not required to be constant but the maximal length must be stated A frame interpreter with the same syntax as for GFBI is used to verify and extract information from it In reply to the message from the device the master sends an acknowledge message This is compiled by a frame compiler with the same syntax as for GFBI questions Below is the syntax graph for a AeACom type definition The command part of the syntax graph is not fully implemented in release 2 0 Abelko Innovation 84 WebMaster Pro WMPro Reference Manual aeadevtype AEADEVICE E fa Statements lt 15 4 AeACom Groups Groups works for AeACom devices exactly as they do for GFBI devices except that the DEVICE keyword in the declaration is replaced with AEACOM like in the example below GROUP RAGGroupO0 OF MAX 60 AEACOM TYPEID 4658 SELECT ONLINE RAGGroup 0
12. Sensors amp Actuators _ Database settings DB Short Time Alarms Time hase minute Time control Add to view menu Yes Overview T Database item Channel name ommunication 1 G1 Temp System 2 G2 Temp Advanced 3 4 G2_Time Channels 5 Err Parameters 6 Curves 7 Databases 9 Summaries 10 Graphical programming 11 Script s Weekday catalog 14 Database email 15 Operator panel menus External units 18 The menu under Settings Advanced Databases lists all the channels in each of the three databases For the short time database it is possible to change the time base The default time base is one second Storing information less often makes room for a longer history The interval for the Hour and Day databases are fixed and cannot be changed By selecting a database item from the list it is possible to change it Any channel can be selected or none if the item is to be removed from the database Every time the database is changed the database must be erased The reason is that in order to save memory only the actual values and time point is stored in the database Not the information about which value it is If the database definition is changed it becomes impossible to interpret the information in the database Abelko Innovation 29 WebMaster Pro WMPro Reference Manual 7 3 Definition Name Type Comment Parameter Name String 20 A name p1200
13. eet tet uie IR 62 13 2 2 ui n UE RR EA DEP NR OE EY PR ERAS 63 13 3 EXAMPLE eene toan edite ite dne 66 13 4 SEMANTICS EXPLANATION 22 2 20 00 00 0200 0000000000000000000000000045000000000000 67 75442 67 13 4 2 PARAMETER PUBLIC and 2 2 212 0000000000000000000000000000050500000020000 67 13 43 BAUDRATE and CHECKSUM a cccccccccccccsssstssecesecsssessscecececsesssuseeeececeesssssseeeseceesesssaeeess 67 13 5 PESME VUDI E NI MOIN S ET E 68 13 5 1 Question compiler definition eese 68 13 5 2 Answer Parser definition edere per re tke breed 68 13 5 3 Floating point support in 4 nennen rennen 69 T Ate tot ettet rir tetti 69 13 6 A MODBUS EXAMPLE a eee ree odieacepsesusecnediGestessedecs cesses 69 Abelko Innovation 4 WebMaster Pro WMPro Reference Manual 13 6 1 WM22 DIN power analyser from Carlo Gavazzi eese ene 69 13 6 2 Reading data and scaling information eese eene 71 13 6 3 general MODBUS DEVICETYPE definition eese trenes 74 13 7 GENERIC aea b op T E 75 ABT De SEXPIGHGLION EHE
14. 10 0 48 94 getparx ssi pararg p1118x0y0z0b64 64 pl100x0y0z0be4 64 Abelko Innovation 105 WebMaster Pro WMPro Reference Manual The returned file could look like this 1 Safety alarm 3 Pressure loss Notice that the flag filter must be applied to all parameter arguments to get a sensible result If we were to use both the x dimension to specify a specific object and the flag filter parameter the result is that all values with an x dimension equal to or higher than x value fulfilling the filter condition is returned http 10 0 48 94 getparx ssi pararg p1118x2y0z0b64 64 p1100x2y0z0b64 064 returns 3 Pressure loss Below is a list with X number parameters and flag word parameters belonging to a certain functionality and parameter range Functionality Parameter range Flag word X number Channel 5xx 513 515 Parameter Oxx 904 906 Alarm 11 1106 1108 Database 12xx 1209 1213 Curve 13xx 1307 1309 Summary page 16 1612 1614 Time control 17xx 1714 1716 Overview 18xx 1805 1807 Database email 19xx 1912 1914 External devices 2000 2029 2090 2092 Connections 21xx 2190 2192 Device email 22 2290 2292 WMsShare typedef 23 2390 2392 79 7 Flags Flags are special parameters collecting state information read and write access levels and other things in a flag word Many of the flags are automatically managed by
15. DEVICETYPEIDSTEXT String Names of all defined p2031 device types These two parameters access the list of all device types defined in the scripts in the WMPro 9 4 Connection definition Name Type Comment Parameter ChnNr byte Connected channel number p2100 DevNr byte Connected device number p2101 ValNr byte Number of the connected p2102 value or parameter Typeld word Type ID number for the p2103 connected device DefaultMode byte 0 use at start up 1 use p2104 at start up and error Default Value float Default value p2105 Time long int Time of last update p2106 Status byte Connection device status p2107 0 OK 1 Fail 2 Trying 3 Disabled 4 Invalid 5 Unused ActionChnNr byte p2108 Flags word Flag array p2191 The type id number of the connected device is stored in the connection when it is created or edited If the external device later is changed so that the type id numbers no longer match the connection becomes invalid The connection has a non standard use of some flags Z 9 set to one means export 0 import from the device to the channel Z 12 is a flag for the trying state Z 13 set means disabled Z 14 is set when the connection is invalid Abelko Innovation 39 WebMaster Pro WMPro Reference Manual 9 5 Device email definition
16. Delete Snippet Upp Down Apply Alias Description Connection OutTemp CHANNEL Outdoor Temp Outdoor Temp RoomTemp CHANNEL Room Temp Forward Temp Radiators CHANNEL Zone 1 Radiators Digital out 1 PARAMETER 36 factor factor SetValue PARAMETER Room temperature setvaluee D_factor Interval PARAMETER Cycle time Update Interval PowerLimit CURVE Outdoor gt Power limit Outdoor Forward ALARM Safety alarm Safety alarm 12 4 1 Editing aliases This table is not only a pretty tool to look at routines with you can actually change the alias connections here By clicking on an element in the connection row you get a drop down list showing all objects of the specified type in the WMPro You can select a new object for the alias Alias Type Description Connection OutTemp CHANNEL Outdoor Temp RoomTemp CHANNEL Room Temp Forward Temp Radiators CHANNEL 2 1 Radiators Digital out 1 PARAMETER l_factor 1 factor SetValue PARAMETER Room temperature setvaluee D factor Interval PARAMETER 36 Cycle time Update Interval PowerLimit CURVE Outdoor gt Power limit Outdoor Forward Stop Safetyalarm CdS afetyatarm Alarm 6 Alarm 7 Pressing Apply will transfer all changes you have made in the snippets tool to the editor window and close the snippets interface If you press close all changes will be ignored The changes will n
17. ER TN 27 5 3 3 Du2 T 27 5 4 WEEKDAY CATALOGUE Sa 27 9 55 SCRIPT NOTES E EEEE pue au DENIM 27 gt E ON DA D 28 6 1 INTRODUCTION 28 6 2 28 7 DATABASES p 29 TA JNTRODUGTION 5 29 722 SETTINGS ADVANCED 5 5 4000 01 a rrr roa neret tren nne nn 29 1 3 DE NA H LOI 30 TA DATABASE EMAIL 22520 2 30 8 SUMMARY PAGES vesssssscccsssscssssiascecessutsesssscesesescensessssessesesscesssosscosesees sbvessodevincsossusecsdbseteessusbveese 32 81 00 32 8222 BASIC ad ted 32 8 3 SUMMARY PAGE 5 4000 0000 32 8 3 1 Text Header and 33 6 3 2 RS Rr e Re soil EIE REO FC ER ERU e det EU ERO ERR ERR EPOR 33 8 3 3 LINK hoe M E ocv o AER 34 8 3 4 Channel value Parameter value
18. FLAGS SHOW1 SHOW2 END Above a channel definition example for a Pt1000 sensor on T1 This definition uses a polynomial to do the translation from ohm to degrees The RTD specialized for this task could have been used as MATH RTD 1000 0 00385 0 but this formula will not give as accurate results at high temperatures New to the 3 0 release is the mathematical function manual override MATH MANUALOVERRIDE manual value time limit Abelko Innovation 95 WebMaster Pro WMPro Reference Manual 18 3 5 Curve definitions Curves can be defined and initialised in the define section DEFINE CurveRegl AS CURVE NAME Curve ctrl 1 XLABEL Outdor temp C YLABEL Setvalue temp C VALUEPAIRS 30 55 15 47 5 40 0 40 5 33 15 17 END DEFINE CurveReg2 AS CURVE 2 NAME Curve ctrl 2 END The valuepairs are pairs of x and y values that defines the curve There is a limit of maximum ten valuepairs Abelko Innovation 96 WebMaster Pro 8WMPro Reference Manual 18 3 6 Alarm definitions NAME Nu B initiator CONDITION H initiator peop on Ju K AUTOMATIC d i ACKNOWLAGABE 4 MANUAL The syntax of an alarm definition holds few surprises and corresponds well to the web page i
19. SILENCE statements is to control the sequence in which a number of telegrams are sent or to send special telegrams when special events occur The Status variable can be used to determine if a transmission was successful or not Variables set when decoding an answer can also be used to signal a successful transmission or to change an internal state Abelko Innovation 80 WebMaster Pro WMPro Reference Manual 14 6 Group statistics The syntax graph for obtaining statistical values of device variables from a group is shown below a public identifier private identifier And here an example zi Z MeanTemp lt StdTemp lt Test MedianTemp lt Test inTemp MED inTemp MI inTemp ST ROUTINE TestGStat ALIAS ChCount CHANNEL 50 MaxTemp CHANNEL 51 MinTemp CHANNEL 52 MeanTemp CHANNEL 53 DiffTemp CHANNEL 54 StdTemp CHANNEL 55 MedianTemp CHANNEL 56 KvlTemp CHANNEL 57 Kv3Temp CHANNEL 58 InterKvartil CHANNEL 59 BEGIN ChCount lt Test COUNT MaxTemp lt Test inTemp MAX MinTemp lt Test Test in DiffTemp lt Test in N D KvlTemp lt Test inTemp Ql Kv3Temp lt Test inTemp 03 InterKvartil D Temp MEAN Temp MAX Test inTemp MI AN lt Test inTemp Q3 Test inTemp Q1 The syntax is quite straightforward COU
20. code float delta Chn Value i Chn MathParl i Chn MathPar3 i Chn MathPar3 i 1 Chn MathParl i Chn MathParl i delta Chn MathPar3 i Chn MathPar2 i Chn MathPar2 i delta Chn Value i Chn MathParl i if Chn MathPar3 i 1 Chn Value i Chn MathPar2 i Chn MathPar3 i 1 else Chn Value i Standard deviation The standard deviation function calculates the standard deviation of the input signal over a period of time The standard deviation will be reset when saved in database or on script command Standard deviation is the square root of variance a measure of how much a signal varies One use can be to measure how good a controller is working A controller with the task to keep something constant should ideally have a standard deviation of zero The accuracy of the calculation is limited by the resolution of floating point values and operations MathPar1 mean MathPar2 S MathPar3 count Abelko Innovation 17 WebMaster Pro WMPro Reference Manual code float delta Chn Value i Chn MathParl i Chn MathPar3 i Chn MathPar3 i 1 Chn MathParl i Chn MathParl i delta Chn MathPar3 i Chn MathPar2 i Chn MathPar2 i delta Chn Value i Chn MathParl i if Chn MathPar3 i gt 1 Chn Value i sqrt Chn MathPar2 i Chn MathPar3 i 1 else Chn Value i 1 Sum Sum adds the
21. feed When a value is fed to a channel it will hold this value until the next time it is updated If the channel is connected to an input the value will be overwritten with a new reading Although allowed feeding values to channel that has a source configuration other than an output is considered bad programming and not recommended If it is connected to an output it will act like a variable but of course send the value with scaling out to the output port If the channel has no source and is not feed values from anywhere else but is configured to do mathematical operations then the situation is interesting After an assignment or feed the channel will hold the value it was assigned Before the next call to the routine the next second the channel will have been updated It then holds the value that is the result of the mathematical operation Using a channel this way makes the program hard to read and is normally not recommended The normal use of channel assignment is to update outputs channels stored in databases and channels monitored by alarms Unconnected channels can also be used for communication between routines and to make internal states visible Abelko Innovation 47 WebMaster Pro WMPro Reference Manual 11 2 2 IF statements The IF statements in the script language has a syntax like in modula2 They are very important as they constitute the only program flow control mechanism in the language if statement
22. limited to 128 characters This is not very much and there is no warning when too much text has been entered The text buffer is simply truncated After editing a page with much text go to the view page and verify that all text looks as it was meant Editing text on one row may cause text on a later row to be truncated It is possible to leave gaps of rows of type none in the page definition This may be a good idea if things will be added later as it is not possible to simply move or rearrange the rows of a page definition Abelko Innovation 37 WebMaster Pro WMPro Reference Manual 9 External Devices 9 7 Introduction The use of external units connections device emails and WMShare type definitions is explained in the user manual The subject will be further discussed in the script section This chapter will therefore mainly consist of parameter number listings 9 2 External Device definition Name Type Comment Parameter Name String 20 A name p2000 TypID word Device definition ID p2001 number DEVICETYPEIDTEXT String Read only device type p2002 name string ComErrorTrigLimit word Number of failed questions p2003 to trigger the fail condition TelegramSettings byte array Telegrams update settings p2004 Code explained in script section ParameterSettings Float array Device parameter values p2005 DEVICETELEGRAMTEXT String array Read only telegram
23. user script routines are executed A call to UPDATE halts the script execution until the inputs and outputs and channels have been updated The DI and DO leds are not updated by calls to UPDATE Abelko Innovation 102 WebMaster Pro WMPro Reference Manual 19 The Parameter Bank 19 1 Introduction The parameter bank is a central part of WMPfro and the Goliath platform The parameter manages all values that can be stored in non volatile memory and all information that can be viewed on web pages A parameter in this context is virtually any piece of information not to be 23 confused with application parameters in the The parameter bank building web interface and script language What we will focus on in this chapter is the http based API used to access values in the parameter bank from web pages applets OPC servers and other application programs Every parameter has a parameter number Usually though parameters are multidimensional and contain many values of the same sort Parameter 501 for example contains all 200 parameter names Up to tree dimensions can be used to specify a single value of a parameter How they are used varies between parameters For parameter 501 the x dimension corresponds to channel numbers Thus p501x1y0z0 refers to the name of channel 1 For http access ssi and cgi functions are used The getpar ssi getpart ssi and getparx ssi are used to retreive values and putpar cgi is used to set va
24. 4 Putpar cgi Invoking putpar cgi from the browser is done in a similar manner The example http 10 0 48 94 putpar cgi p501x1y0z0 Test will set the name of channel 1 to Test The WMPro will return a web page containing a message from the parameter bank If successful the message is PUTPAR OK Abelko Innovation 104 WebMaster Pro WMPro Reference Manual Change the y value to one which is illegal for parameter 501 The parameter bank will return the error message PUTPAR p501x1y12z0 Invalid arguments or data 79 5 Getpart ssi Getpart ssi works exactly like getpar ssi but it appends an end of transmission character EOT ascii code 4 19 6 Getparx ss The getparx ssi is an extended version of getpar It can do everything getpar can and is used in the same way Getparx can handle much larger chuncks of data and can return parameter lists that are to big for getpar like the list of all channel names Getparx also has some extended features that will be explained here 19 6 1 Multiple parameter retrieval GetParX allows you to specify several parameters in one request The parameters are separated by a semicolon To retrieve all channel names values and units in one request an URL like this can be used http 10 0 48 94 getparx ssi pararg p501x0y0z0 p507x0y0z0 p502x0y0z0 The answer consists of values separated by comma signs and rows separated by semi colons The result ma
25. 75 45270 EXAMPLES eR eet RE REC RR RESET DR RE REED RR UR E P RE E na e 75 372 DE E E VA O E E A eei tert eo E e vett tie o noted eive 75 13 4 kc eicere ber bie v br boten pides 75 13 7 5 XMODEM Kermit eene hehehe hehehe nene nene n inen enini nene nene 75 13276 PETER 75 14 GROUP SCRIPTS wu 76 141 5 EE PEEL 76 14 2 SYNTAX cciam retenir ito t e E e e reete ove te pter 76 14 3 77 14 4 SELECTION EXPLANATION ccsssssscecececsessnccecececseneseaecececsesescaecececseseseaecececeesenseaeeececeenes TT 14 5 ITERATOR EXPLANATION ier tre Eee y Ue Pe ERE E GRE EE ECKE Reve ee RETE RUE Ue GRO sees 78 14 6 GROUP STATISTICS ecoute teri Ert t Uie E QE 81 15 AEACOM SCRIPTS wsccscccsvensssssssssasenessossetsacssnaneesesesssecssacvsnsesentessacedenseseescsdescesencssesssessesexessese 83 15 1 INTRODUCTION wie sti de eae RUE E ERES 83 15 2 AEACOM CONFIGURATION cccccssssssececececeesssccecececseseseaecececsesesaaececccecseseaaeeeecesesensaaeeeeecs 83 15 3 AEACOM TYPE DEFINITIONS csssssccecececsessscec
26. Bank byte Memory bank used p1201 MinSector byte Start sector number p1202 MaxSector byte End sector number p1203 UpdateInterval Long int Update interval in seconds p1205 UpdateOffset Long int Interval offset in seconds p1206 SelChnNr Byte array The numbers of the channels to p1204 stored PostPeriodal byte 0 pre periodal time stamps 1212 1 post periodal time stamps Flags word Flag array p1210 Databases are stored in flash memory with a sector size of 64 kByte The memory is banked but databases 1 to 6 always uses bank 0 Bank 0 has 16 sectors that can be assigned to databases MinSector must be lower than MaxSector Nothing prevents the assignment of overlapping sector ranges but the result will be databases that do not work even though they may seem to work for a while UpdateInterval defines how often values should be saved This is based on the real time clock so setting interval to 3600 seconds will cause the database to save data the first second of every hour UpdateOffest can be used to change when within the hour data should be saved In WMPro offset is set to 3599 for the hour database causing data to be saved the last second of every hour The equivalent is true for the day database In WMPro PostPeriodal is set to 1 This causes the database to save the time stamp in the database to the time when the save is made When PostPeriodal is set to zero the time of the start of the interval is saved as ti
27. O 01 DATA 1 HEX FE DATA 2 HEX 14 DATA 3 HEX 52 DATA 4 DATA 5 BYTE Id DATA 6 HEX 10 DATA 7 gt WORD Z1 0 ROUND DATA 25 6 DATA 9 gt WORD Z2 0 ROUND DATA 25 6 DATA 11 gt WORD 23 0 ROUND DATA 25 6 DATA 13 gt WORD Z4 0 ROUND DATA 25 6 DATA 15 WORD inTemp 0 1 ROUND DATA 25 6 DATA 19 BYTE D DATA TIMEOUT 1000 END END Abelko Innovation 66 WebMaster Pro WMPro Reference Manual 13 4 Semantics explanation 13 4 1 First row The first row from DEVICETYPE to IS is not very complicated The identifier directly after the DEVICETYPE keyword is there for consistency more than anything else It is not possible to reference a device type by this name from anywhere else in a script The TYPEID number is the only way to reference a type The reason for this is that the name follows normal scope rules and does not survive between different scripts It should however be possible to access a device type defined in application script from a user script and using the device number it is The device number is a number between 1 and 65535 Each device type must have a number that is unique in the WMPro To avoid potential errors and confusion they should be truly unique The NAMED string is the name for the device type as it will be presented on the web pages 13 4 2 PARAMETER PUBLIC and PRIVATE After the
28. On standard hardware 1 to 8 are DIGITAL IN 9 to 16 DIGITAL OUT 31 is ALARM and 32 is system 7 DOUT OUT Digital outputs 1 to 8 DOUT 1 to DOUTS 8 DOUT F OUT Frequency outputs none on WMPro 9 AOUT U OUT Analogue voltage outputs 1 to 8 AOUTI to AOUTS 10 AOUTI OUT Analogue current outputs None on WMPro 11 5 5 IN System variables Explained separately 12 CHANNEL IN Input from another channel Connection number equals channel number 13 COUNTER IN Counter inputs 1 to 4 corresponds to counting pulses on DINI to DIN4 When a channel is connected to an input it will each second be updated with the value from the input with scaling applied If it is connected to an output the channel value will be scaled and then put to the output Note on LEDs The LEDs on a WMPro are automatically managed Connecting a channel to a LED will however override the automatic function The value 0 turns the LED of 1 on and 2 makes it blink LED 32 is connected to channel 200 by the application script The hardware is prepared for more LEDs than normally mounted and there are alternative positions for some LEDs Note on Counters The COUNTER input type does not store counter value When a channel is connected it will store the counter value Every second the channel value will be increased by the number of counts registered in the past second 2 3 1 Update Order In some cases the ord
29. The rest of the flags in the flag parameters are for internal use in the parameter bank only Abelko Innovation 107 WebMaster Pro 8WMPro Reference Manual 79 8 Backup par and putpar par As mentioned in the introduction backup par is a generated file that contains a complete image of the parameter bank It is a readable text file that is generated when requested and that is why it takes some time to download it Below is a small extract from a backup par as example on what it can look like RW F p501x192y0z0 Channel 192 V F p501x193y0z0 Channel 193 V F p501x194y0z0 Channel 194 V F p501x195y0z0 Channel 195 V F p501x196y0z0 Channel 196 V F p501x197y0z0 Channel 197 V F p501x198y0z0 Channel 198 V F p501x199y0z0 Channel 199 F p501x200y0z0 Status Led VE p502x1ly0z0 C p502x2y0z0 C 502 3 0 0 p502x4y0z0 C p502x5y0z0 C p502x6y0z0 C 502 7 0 0 p502x8y0z0 C p502x9y0z0 V 1 502 10 020 2 2 2 2 2 2 2 El Ei Bd Bd Ed Ed Gd Bd Ed Dd J J Dddd DD DDD HA This file can be uploaded to the file pupar par The file is then interpreted and the parameter bank is set exactly as described in the file Editing this file makes it possible to copy selected settings from one WMPro to another By removing all lines for parameters with parameter num
30. WORD and RWORD typecasts the value to and int and assigns it to byte n and n 1 Word uses big endian and RWORD little endian FLOAT stores the value as a four byte float When using the left arrow assignment lt one or several statements are expected between the left and right parenthesis after the keyword Allowed keywords are BYTE WORD RWORD and FLOAT The execution of the statements must result in that the special variable DATA is assigned a value DATA is an automatic variable that is in scope for these statements The main intended use for this construct is to allow IF statements The GFBI automatically appends the checksum as defined after the highest frame index used If not all bytes in the frame are assigned a value the result is unpredictable 13 5 2 Answer parser definition For an answer the expected size in bytes must be defined Any reply with the wrong size is considered faulty The checksum must also be correct A special counter keeps track of checksum errors It is accessible from the view external devices page along with other communication statistics for each device Next step in validating the answer is by the answer parser Individual bytes and words in the received frame are accessible with the DATA n keyword as for the question compiler Here data is not assigned but with equal operator a check is made that the data in the frame equals the expression on the right side of the equal sign HEX BYTE
31. also see a possible a third condition the PREFIX condition This is a name based condition requiring the name of the device to start exactly as the supplied string D 1003 I GROUP Lgh OF MAX 10 DEVICE TYPE SELECT spTemp 0 PREFIX Lgh 14 5 Iterator explanation In the example and syntax graph we can se a SORT BY statement This statement is followed by an expression This statement is optional but when it is present the group member list will be sorted in ascending order based on the evaluated value from this expression Iterators will be applied to devices in this order Do not use the SORT BY statement if the order is not important as evaluating the expression and sorting the list takes extra computer power A group can have many iterators or none defined They are pretty much like routines but with a few differences An ALIAS section is allowed but there can be no VAR section All variables are defined in the DEVICETYPE definition Parameters public and private variables are all regarded as variables in the iterator This means that it is possible to assign values to device parameters but this is not normally recommended The new value will not be displayed to the user and will be overwritten if the user changes any device setting not only the specific parameter There are also a few automatic variables that can be used in expressions in an iterator
32. and Alarm status 34 8 3 5 aM e m a o eae Cea tae 34 8 3 6 QT M SOM 35 6 3 7 Edit p r niet r I RI UD e 36 8 3 8 diete 36 8 4 LIMITATIONS OF SUMMARY PAGES cccccecececececececececececececececececececececececececececececececececececececess 37 9 EXTERNAL DEVICES esce eo ra ie ovp ease pe roa debo ve ee epo epo veo 38 Abelko Innovation WebMaster Pro WMPro Reference Manual 9 INTRODUGIION innen patentes 38 9 2 EXTERNAL DEVICE DEFINITION eseeeeeeee entere nennen inneren tene 38 9 3 DEVICE TYPE DEFINITION PARAMETERS 202022 ener enne ener 4 39 9 4 CONNECTION DEFINITION ener enne en 39 9 5 DEVICE EMAIL DEFINITION eeeeeeeeeeeennee r nennen ente E E EG E A 40 9 60 WMSHARE PARAMETERS 1 44 4 44 420 0 r eren nene sese E a aE 40 10 THESCRIPT EANGUAQGE inseeostcesssses cese esse eek ases seo ee vasre esssS rey eene roga 41 10 1 INTRODUGCTION A Did ud tm 42 10 2 LANGUAGE BASICS 2 Lat e dd e tete 42 10 3 HOW TO READ A SYNT
33. bigger graph That is why there is no endpoint The bigger graph provides a loop back from the right side to the left side The FLAGS keyword can be followed by one or many of the keywords SHOW1 to SHOWS The listed keywords represents flags that will be set those not listed will be cleared The show flags can be used by web pages to categorize channels and other items Write and read access can also be defined in the flags section The last keyword defines the login level required for access DEFINE T1 AS CHANNEL 1 NAME Temp 1 UNIT C DECIMALS 1 SCALE 1 OFFSET 0 SOURCE AIN R 1 MATH RTD 1000 0 00385 0 FLAGS SHOW READ GUEST IRITE CONFIG zi z O 4 In Release 2 0 flag initialisation is only implemented for CHANNEL and PARAMETER In WMPro for channels the show 1 flag is used to indicate that the channel is connected to a sensor Show two is used to indicate that the channel is not digital assignable These flags are used by some web pages and applets to filter out channels for drop down lists Abelko Innovation 100 WebMaster Pro WMPro Reference Manual 18 4 Procedures and Statements 18 4 1 Procedures procedure PROCEDURE ns H Procedures just like routines except that there is no restriction on which statements that can be used These non l
34. channel is increased by one Abelko Innovation 25 WebMaster Pro WMPro Reference Manual 5 Time Control and Weekday Catalogue 5 1 Introduction Time control is used to program the WMPro to do certain things at certain points time The time control itself will evaluate to either false or true a value that can be used in scripts including controllers and graphical programs As the time control functions are well described in the user manual the reference manual will only address some specific information not enclosed in the user manual 5 2 Definition A Time Controll can be of three different types who use the parameters in different ways Each time control also holds an array of time point definitions The number of time points is limited to ten Name Type Comment Parameter Name String 20 A name p1700 Type byte 0 Time 1 Date 2 Week p1701 Value byte Current state p1702 ItemActive Byte array Time point used 1717 Long int p1704 array TimeDuration Long int p1705 array TimelIntervall Long int p1703 DateStart Long int p1706 array DateStop Long int p1707 array WeekStart Long int p1708 array WeekStop Long Int p1709 array WeekDayMask Byte bitmask p1710 array Flags word Flag array 1715 5 3 Time Control types 5 31 Time The Time controll type Time is used for strictly periodic time controlls TimeIntervall ho
35. decimals to display p903 Flags word Flag array p905 Name and Unit are strings of maximally 32 and 8 characters respectively parameter value is normally displayed as name value unit like Setpoint 16 2 C The value of the parameter Decimals decides how many decimals to display when printing the value In the example this was set to 1 but may be 0 to 5 Nr Name Value Unit Dec Erase 1 Setpoint 16 2 1 Erase 2 Data 2 0 0 1 Erase O 3 Data 3 0 0 1 Erase The values of a parameter definition can be edited in the list of parameters under Settings Advanced Parameters in the web interface The flags cannot be edited from the form as they are automatically handled Press save when done editing 3 3 A Warning Decimals The Decimals setting only tells how many decimals will be shown it does not round the actual value Setting a parameter to 3 14 and the number of decimals to 0 will give the parameter the value 3 14 but when displayed it will be shown as 3 This may be somewhat confusing When the parameter is edited the next time the value will be shown as 3 If the user then press OK this will be saved and even though the user believes nothing has been change the value will actually be changed from 3 14 to 3 A strong recommendation therefore is to always show all used decimals Abelko Innovation 23 WebMaster Pro WMPro Reference Manual
36. mean that it has z number 8 in the flag array 19 7 3 z 16 The Script flag The script flag is set for objects that are used by scripts This flag is set or cleared on every boot when the scripts are compiled The script flag is bit 15 and is referred to by 7 16 19 7 4 The Show flags All flag parameters except the flag parameter for external devices has three free flags called show1 show2 show3 They bit number 12 13 and 14 and thus use z number 13 to 15 These flags have no preset function They can be used to build customized filters for web pages and applets In WMPro these flags are used only for channels where show has the meaning of sensor channel show2 not digital assignable channel 19 7 5 z 9 The Backup flag Channel values are normally set to zero at start up in order to make the start up sequence of a system predictable If there is some reason to use a channel more like a parameter this flag can be set The channel value will then not be reset at start up instead the stored value will be used The channel value is always saved when written to using putpar cgi and when the system is reset in a controlled way If the channel is updated by a script the value is not saved every time the script writes to it It is saved only at controlled resets and at the regular backup intervals every hour shift Using this flag is not recommended unless there are compelling reasons 19 7 6 The other flags
37. name p2010 string DEVICEPARAMETERTEXT String array Read only parameter name p2011 string DEVICEVALUETEXT String array Read only value name p2012 string DEVICEUNITTEXT String array Read only value unit string p2013 DEVICESTATUS byte Status number 0 ok 1 p2020 fail 2 trying DEVICEVALUE Float array Device value p2021 DEVICETIME long int Time of last update in p2022 seconds since 2000 01 01 Flags word Flag array p2091 External devices are more complex than the functionalities already discussed Information is managed not only by the parameter bank but also by the GFBI or AeACom motor Only the names that are not all capital letters represents values actually stored in the database The other values are retrieved from the appropriate communication motor The communication motors keep their own working copy of some of the information in the parameter bank This becomes apparent for the ParameterSettings These settings are copied to the motor at start up and whenever a new value is written Device parameter values can also be affected by channel connections or group scripts This will affect the working copy of the parameter setting but not the value stored by the parameter bank Abelko Innovation 38 WebMaster Pro WMPro Reference Manual 9 3 Device type definition parameters Name Type Comment Parameter DEVICETYPEIDS word All defined device type ID p2030 numbers
38. should be lowered from the normal temperature The temperature is lowered when the apartment in uninhabited and thus it is reasonable and desirable to also turn of the hot water to save energy 14 4 Selection explanation A group is defined with an identifier Lgh in the example It is also necessary to define the maximum expected number of members in order to allocate the right amount of memory The TYPEID number defines what type of units can be members and which device variables are accessible After the TYPEID number there is a select condition ALL means all devices of the right type will be members as long as their number does not exceed the group maximum number Abelko Innovation 77 WebMaster Pro WMPro Reference Manual Using the ONLINE keyword requires the devices to have status OK to be allowed membership For groups where sensors are read this is recommended as devices that are not OK will not have fresh and valid information For groups used for output as in the example it can be better not to have the ONLINE requirement Otherwise invalid data may be sent to the devise in the first telegram before the unit is OK All units are reported as Trying 2 directly after power up A Trying device is not online The ALL keyword can be replaced with an expression using the device variables and parameters We could change the example to make the group contain only devices with sbTemp 0 Looking in the syntax graph we
39. the parameter bank The flag word itself can be read but not directly written to To set a flag the flags array parameter is used instead This parameter allows access to individual flags trough the z dimension The functionalities sections chapter 2 to 9 presents the parameter number for the flag array parameter in all the functionalities The table of flag words in the chapter on getparx refers to the flag word parameter The flag word and the flag array are different ways of presenting the same information The flag array has always the parameter number after the flag word Abelko Innovation 106 WebMaster Pro WMPro Reference Manual Some flags are common to all flags parameters while other may have different meaning for different functionalities 19 7 1 z 7 The Used flag The used flag is used to indicate that the object it refers to is used for something For some functionalities this flag is automatically managed and set as soon as there is a write to any other parameter in the object For other functionalities this flag is used to manually activate the object The used flag is bit 6 in all flag parameters which mean that it has z number 7 in the flag array 19 7 2 z 8 The Edited flag The edited flag is used to indicate that the object has been edited by the user It is automatically set by the parameter bank when a parameter in the object is written to by putpar cgi The edited flag is bit 7 in all flag parameters which
40. there is a description on how to read an instrument type identification code This code should be 14 The question to send is 01h 04h 00h OBh OOh O1h 40h 08h Abelko Innovation 69 WebMaster Pro WMPro Reference Manual The instrument should reply with Olh 04h 02h 00h 38h F4h The first byte is the slave address the second is the function code Four is the code for read register In the question the next two bytes is the register address followed by two butes specifying the number of registers we want to read The last two bytes is the CRC The reply starts with the same two bytes as the question The third bytes is the number of bytes that follows before the CRC Then come two bytes of data the instrument type code Last is as always two bytes of CRC Below is code for a DEVICETYPE for WM22 with a telegram definition to read the instrument type code DEVICETYPE WM22 NAMED WM22 DIN TYPE PARAMETER Id Address PUBLIC TypeCode Type Code L1U Vol tage pM L2U L2 Voltage L3U L3 Voltage V L1I L1 Current A L21 L2 Current A L3 Current A LIP L1 Power W I D 2001 IS L2P L3P PRIVATE VScal AScal PScal BAUDRAT e e e E 2 P
41. to define local variables This is done in the var section where variable names simply are stated Since the script language has no types this is all that is needed variables are initialised to zero when execution starts They are unlike normal local variables in Modula2 Pascal or C persistent between calls If a value is assigned to a variable the variable will hold this value until assigned another value or until the system is restarted Abelko Innovation 46 WebMaster Pro WMPro Reference Manual 11 2 Statements LT Statements includes assignments if statements and other things that actually do something Statements lt is the limited subset of statements that are allowed in routines statements 1t assign_var if_statement os B reset statement log statement debugprint 11 2 1 Channel and Variable assignment The assign var sub graph describes the syntax for assigning variables and channels assign var B variable channel When a variable is assigned a value it will store that value until it is assigned another value Therefore this assignment uses a unconditional assignment operator expression Assigning a value to a channel has a different syntax as it has a slightly different meaning A channel is not a simple variable it can be defined to things with the value like filtering or summing The operator lt should not be read as assign but rather as
42. x AND gt 7 0 000000 SIGN x PI 1 000000 SORT x 2 000000 SORT 1 0 000000 2 0 999999939489602418518643389688 804746 LN 1 999999939489602418518643389688 804746 LOG10 0 999999939489602418518643389688 804746 The last four examples are examples of illegal mathematical operations They do however give results anyway The results are the most reasonable results possible and will prevent the system from crash The last three are large numbers that represents positive and negative infinites Abelko Innovation 55 WebMaster Pro WMPro Reference Manual 12 The Script Editor Selecting Settings Advanced Script brings up the script editor The editor loads the user script file but filters out the part of user script three meant for user edit and displays only that The main features of this editor are the syntax highlighting alias generating assistance and the save button that checks syntax before saving Additional features are available in the snippets interface where routines and can be saved and loaded in goliath platform skript snippets files 12 1 Syntax highlighting Below is an example of a script in the script editor Save Snippets CHANNEL Digital out 1 7 Insert Alias ROUTINE ExampleCtrl O n Off pulsing controller for electric radiators 3 ALIAS utTemp CHANNEL 1 sOutdoor Temp RoomTemp CHANNEL 2 Room Temp Rad
43. 485 Information on MODBUS is available at www modbus com The standard specifies how a frame should look like with a header and a CRC It also specifies some standardized function numbers and how they should work and exception codes Data is accessed trough registers Register addresses and their contents is device and manufacturer specific There should be a specification available for each MODBUS device specifying which function codes are supported and what register addresses are used and how to interpret their value Writing a GFBI devicetype specification for a MODBUS device should be quite straightforward MODBUS on RS485 comes in two flavors RTU and ASCII RTU is the binary form and the one that can be handled with GFBI The MODBUS standard says that all slaves must support RTU mode ASCII mode is optional Address Function DATA CRC CRC Code Basic outline of a MODBUS frame 13 6 1 WM22 DIN power analyser from Carlo Gavazzi In this example we will write a type definition for a power analyser from Carlo Gavazzi the WM22 DIN The protocol specification document states that that this module uses MODBUS RTU on 5485 with 9600 baud one start bit 8 data bits one stop bit and no parity This mean that it should work just fine with the GFBI This unit does many things but we want to read voltage current and power on three phases We will however begin with something simple In the specification document
44. AX GRAPH i eee en nennen entrer enne en rennen 43 11 LIO HEIL HE CREE 44 11 1 6 22 aede eee 44 11414 tet 45 11 22 Variables 46 11 2 STATEMENTS LT te etie eed 47 11 2 1 Channel and Variable assignment esee 47 11 2 2 IF statements 48 11 2 3 1 seen 49 11 2 4 49 11 2 5 Call StQteme nts 49 126 Acknowledges iiie ene tee Bee ed iHe e EEEE EE 49 11 2 7 Disable and enable alarms esses ener enne etnies n 49 11 2 8 Set and Clear manual override esee eese 50 1122595 Commehlss wo eotdenen oma Os tane redet Os ive es 50 11 3 EXPRESSIONS ne even ee a n aus 52 11 3 1 Unaryoperators is dca ed ede eden eive nuire aie beside Ede es 52 3 20 LNG OD CV ALOPS reote dye feed pere EO rte 53 11 3 3 Parenthesis a
45. Ls eowmoven H Reco Beal M onum Li Le g Ee suwog 9 j mmeer PD Jo TERMISTOR POLY koan a C pG G The semantics MATH function initialisation will be explain here The math functions themselves are explained in the chapter about channels MATH VARIANS MATH STD These two statistical functions need no arguments If they are included in a database the database will reset them on each update Otherwise resets have to be done with the RESET statement MATH COUNTOVER limit MATH COUNTUNDER limit MATH COUNTPULSE limit MATH COUNTOVERDB limit MATH COUNTUNDERDB limit MATH COUNTPULSEDB limit The argument of all count functions is the limit value The count functions come in two flavours Those who end with DB will be reset by a database update the others will not Abelko Innovation 94 WebMaster Pro WMPro Reference Manual MATH ARFILT factor The argument of ARFILT is the filter factor This should be a number between 0 and 1 in order for the filter to be stable 0 means no filtering 1 means that the value will never change MATH MEAN interval MATH MIN interval MATH MAX interval The argument for
46. MEAN MIN and MAX is an interval If this number is bigger than 0 they will automatically reset after interval seconds With 0 as argument they will not reset automatically but by database updates and the RESET statement A reset will set the value to the most resent measured value MATH DIFF scale The argument for the DIFF math function is a scale factor MATH SUM scale limit MATH SUMDB scale limit The two summing functions have two arguments The first is a scale factor the second is a sum value limit When the absolute value of the sum has reached the limit it is not allowed to grow more SUM will not be reset by a database update but SUMDB will MATH RTD RO Alpha TO MATH THERMISTOR RO TO Beta MARTH POLY a How these functions work is explained in the chapter about channels The order of the arguments is shown above As these are conversion functions there is no meaning resetting them MATH HOURMETER limit unused conter value MATH DBDIFF last ch value last change hold last change The hourmeter is not meant to be reset and the dbdiff function is reset by a database DEFINE T1 AS CHANNEL 1 NAME Temp 1 UNIT C DECIMALS 1 SCALE 1 OFFSET 0 SOURCE AIN R 1 MATH POLY 246 009 0 2361 0 00000991
47. N VScale 10000 ELSIF DATA 1 THEN THEN VScale 100000 ELSIF DATA 12 THEN THEN Abelko Innovation 71 WebMaster Pro WMPro Reference Manual VScale 1000000 ELSE VScale 0 ENDIF DATA 4 gt 3 AScale 0 001 ELSIF DATA 4 THEN THEN AScale 0 01 ELSIF DATA 5 THEN THEN AScale 0 1 ELSIF DATA 6 THEN THEN AScale 1 ELSIF DATA 7 THEN THEN AScale 10 ELSIF DATA 8 THEN THEN AScale 100 ELSIF DATA 9 THEN THEN AScale 1000 ELSIF DATA 10 THEN THEN AScale 10000 ELSIF DATA 11 THEN THEN AScale 100000 ELSIF DATA 12 THEN THEN AScale 1000000 ELSE AScale 0 ENDIF DATA 5 gt IF DATA 3 THEN THEN PScale 0 001 ELSIF DATA 4 THEN THEN PScale 0 01 ELSIF DATA 5 THEN THEN PScale 0 1 ELSIF DATA 6 THEN THEN PScale 1 ELSIF DATA 7 THEN THEN PScale 10 ELSIF DATA 8 THEN THEN PScale 100 ELSIF DATA 9 THEN THEN
48. NDS END 18 3 8 Log entry definitions A logentry is a message that can be enterer to the alarm event log by a script The message to be entered must be defined by a logentry definition LOGENTRY NAME MESSAGE DEFINE LigthOnMsg AS LOGENTRY 1 NAME Ligth On MESSAGE The ligth in the building was turned on END DEFINE LigthOffMsg AS LOGENTRY 2 NAME Ligth OFF MESSAGE The ligth was turned off END DEFINE LightInDiff AS CHANNEL 55 NAME LigthIn SCALE 1 OFFSET 0 SOURCE DIN 2 MATH DIFF 1 END ROUTINE CheckLigth F LightInDiff 0 THEN LOGENTRY LigthOnMsg ENDIF Abelko Innovation 99 WebMaster Pro WMPro Reference Manual IF LightInDiff 0 THEN LOGENTRY LigthOffMsg ENDIF ND example above uses DIFF digital input to detect status changes and add messages when something happens NOTE LOGENTRY will not work in release 2 0 18 3 9 Flags For many of the functionalities that can be defined initialised there are also flags that can be initialised This has been left out to save space and as it works in the same way for all functionalities CONFIG This graph is a part of a
49. NNEL 50 Counting on time for GoLeft TimeRigth CHANNEL 51 Counting on time for GoRigth VAR Direction BEGIN IF Direction 0 THEN GoLeft NOT LeftEnd GoRigth 0 ELSE GoLeft 0 GoRigth NOT RightEnd ENDIF IF LeftEnd AND Direction 0 THEN Direction 0 RESET TimeLeft PRINT Left end reached Direction Direction ENDIF Abelko Innovation 50 WebMaster Pro WMPro Reference Manual IF RightEnd AND Direction 1 THEN Direction 1 RESET TimeLeft PRINT Right end reached Direction Direction ENDIF CALL IfExamples END This is an example on print reset and call statements as well as on comments The idea behind the example is some sort of system going back and forth between two endpoints Every time and endpoint is reached the direction is changed and a debug message printed TimeLeft and TimeRight are supposed to be channels that count the on time for the GoLeft and GoRigth outputs The counters are reset every time the direction is changed They could be monitored by alarms to detect fault conditions when the endpoint is not reached in reasonable time Abelko Innovation 51 WebMaster Pro WMPro Reference Manual 11 3 Expressions Expressions are mathematical expressions that will result in a single number An expression may be a single digit or a complex mathematical formula wit
50. NT is a little bit special as it operates directly on the group and returns the number of members in the group other keywords require that a device variable or parameter is identified Note that there is no alias for the group named Test A group is accessible and in scope for all routines after the group definition in the same script Abelko In novation 81 WebMaster Pro WMPro Reference Manual Keyword Description MAX Returns the highest value in the group MIN Returns the lowest value in the group MEAN Returns the mean of all values in the group STD Returns the standard deviation for all values in the group MEDIAN Return the median value of the group If COUNT is odd this is the middle value if it is even it is the mean of the two middle values QI Returns the first quartile of the values in the group If COUNT is even this is the median of the lowest COUNT 2 values If COUNT is odd it is the mean of the lowest COUNT 2 1 values Q3 Returns the third quartile of the values in the group If COUNT is even this is the median of the highest COUNT 2 values If COUNT is odd it is the mean of the highest COUNT 2 1 values Every time this kind of expression is invoked the value must be evaluated for all devices in the group and then the statistical value evaluated For MEDIAN Q1 and Q2 this involves sorting For large groups this may be time consuming If a value is needed
51. NTRODUCTION 5 5 eterne bar eu iue ae Ua 2 2 DEFINITION 2 3 10 2 3 1 Update Order 2 eo ee bee e dede 10 2 352 System IDUTSL dte eere edere les 11 2 3 3 Unconnected channels 5 deest diese 12 24 R o Am ISI nS 12 2 5 MATHEMATICAL FUNCTIONS a eerte ener RON e I e RE E 13 3 UP 919 LE OR WOLLE 23 3 15 INDRODUCTION EE 23 3 202 23 3 3 A WARNING ON 22 24 l INTRODUCTION ies 24 AD 252 24 43 A ARM CONDITIONS Mee eue EA T TS 24 4 4 ALARM ACTION CHANNEL tese tese tese eese 25 5 TIME CONTROL AND WEEKDAY CATALOGUE unui csssssccsscsccccssscccssssccccsssccscsssseeees 26 5 1 PI E 26 5 2 DEFINITION x vier rd DU P ORE IR 26 5 3 TIME CONTROE TYPES 26 5 3 1 uc 26 5 3 2 8 412 ToC
52. PARAMETER keyword all parameter variables are defined The definition consists of an identifier and a name string The name string is used on the external device settings page as parameter values can be set by the user After the name string comes optionally a unit string and a format specifier In the script these variables are not assignable The variables after the keyword PUBLIC are pretty much the same but these are true variables and their string names and values are presented on the external devices view page Variables defined after PRIV ATE does not have an associated string as they are not presented to the user 13 4 8 BAUDRATE and CHECKSUM The BAUDRATE definition sets the baudrate for all telegrams The number must be between 300 and 115200 The CHECKSUM definition defines what kind of checksum is used on the telegrams It is used both on questions and replies SUMS is simply the sum of all bytes stored in a single byte ZSUMS is the same thing but the checksum value is such that the sum of all bytes including the checksum is zero The optional SKIP number defines that a number of bytes in the beginning should not be part of the checksum SUM16 and ZSUM16 is basically the same thing but with word 16 bit size sums For these there is also the option SWAPPED In the WMPro integers are stored in the big endian style with the high byte last If the protocol uses little endian use SWAPPED The MODBUS keywords sets the c
53. PScale 1000 ELSIF DATA 10 THEN THEN PScale 10000 ELSIF DATA 11 THEN THEN PScale 100000 ELSIF DATA 12 THEN THEN PScale 1000000 ELSE PScale 0 ENDIF TIMEOUT 1000 END Abelko Innovation 72 WebMaster Pro WMPro Reference Manual The scaling information is decoded directly in the answer parser If addresses where the byte codes are retrieved from seems strange that is because Carlo Gavazzi uses a direct memory map of registers not really in line with the Modbus intentions Next step is to retrieve the actual values They are to be read from register 0200h to 0212h A single telegram is sufficient TELEGRAM ReadMeter NAMED R Meter IS QUESTION DATA 0 BYTE Id DATA 1 HEX 04 2 02 DATA 3 00 4 00 5 09 ANSWER SIZE 23 DATA O BYTE Id DATA 1 HEX 04 DATA 2 HEX 12 DATA 3 gt WORD L1U DATA VScale DATA 5 gt WORD L2U DATA VScale DATA 7 gt WORD L3U DATA VScale DATA 9 gt WORD L1I DATA AScale DATA 11 gt WORD L2I DATA AScale DATA 13 gt WORD L3I DATA AScale DATA 15 gt WORD L1P DATA PScale DATA 17 gt WORD L2P DATA PScale DATA 19 gt WORD L3P DATA P
54. R Timer Power BEGINx Timer Timer 1 IF Timer gt Interval THEN Timer 0 ENDIF Power Power I SetValue IF Power gt PowerLimit OQutTemp THEN Power PowerLimit OutTemp ELSIF Power lt 0 THEN Power 0 EID TEs Messages Position Row 567 Col 7 UserScript gps line 568 col 8 Syntax error Expected Found Timer In the example above an x has been inserted right after BEGIN making that keyword invalid When saving the WMPro replies after a few seconds with the message UserScript gps line 568 col 8 Syntax error Expected Found Timer First don t be confused by the high line number The line number refers to the whole userscript file which may include controllers graphical programs and other things you do not se The position of the cursor is always shown above the message window The erroneous x was inserted at row 567 col 7 Abelko Innovation 57 WebMaster Pro WMPro Reference Manual Finding the cause of an error message is not always a simple task The parser expected a instead of Timer on row 568 but that will not correct the misstake What has happened is that the parser accepted BEGINXx as another variable name and as such it should have been followed by a semi colon In this case it is quite easy to se that the BEGINXx is incorrect as it is no longer colour coded blue When searching for syntactical errors they are either located where the error me
55. Scale TIMEOUT 1000 END Abelko Innovation 73 WebMaster Pro WMPro Reference Manual 13 6 3 A general MODBUS DEVICETYPE definition The definition below can be used to test a Modbus device The device address and register to be read are parameters The register will be read using function code 4 and stored in public variables both with native and reversed byte order Normally Modbus devices should use the reversed order D 2000 DEVICETYPE ModbusRegister NAMED MODBUS Reg TYPE Is PARAMETER Id Address Register Register PUBLIC Val Value RVal RValue PRIVATE VScale AScale PScale BAUDRATE 9600 CHECKSUM MODBUS SWAPPED TELEGRAM ReadRegister NAMED R Register IS QUESTION DATA O BYTE Id DATA 1 HEX 04 DATA 2 RWORD Register DATA 4 HEX 00 DATA 5 HEX 01 ANSWER SIZE 7 DATA O BYTE Id DATA 1 HEX 04 DATA 2 02 DATA 3 gt WORD Val DATA DATA 3 gt RWORD RVal DATA TIMEOUT 1000 END END Abelko Innovation 74 WebMaster Pro WMPro Reference Manual 13 7 Generic CRC This chapter explains the CRC8 and CRC16 syntax subtrees in the syntax graph of a GFBI type definition in section 12 2 2 13 7 1 Explanation CRC is
56. TYPEID 22100 ACTIONS VhoRU 15 CountData 15 ReadBlock 12 SetTime 23 NIT Dummy 0 END The example above initialises a single device Telegram update code 15 means one minute update intervals 12 mean 30 seconds and 23 for the SetTime telegram means five minutes The example below initialises a range of devices as AeACom automatic DEVICE DEV 1 TO DEV 60 4658 AUTOMATIC END Abelko Innovation 88 WebMaster Pro WMPro Reference Manual 18 Application scripts 78 7 Introduction Application scripts are stored in the file appscript gps The application script can do everything that the user scripts can do and a little bit more Most importantly the application script can do initialisations on a large number of settings including for example channel and parameter settings The application script can also run special script code at start up This code is allowed to run procedures Procedures are routines that are allowed to do more things Things that are dangerous to allow in routines as they causes writes to the parameter bank The memory where the parameter bank is stored has a limited write erase cycle life time and writing every second would soon destroy the memory The application script is an important part of WMPro and is part of updates and releases just as the firmware and webpage s are The applica
57. WORD RWORD and FLOAT are used exactly as they are in colon equals assignment in questions If one or more equalities do not hold the frame is considered faulty A format error counter will be increased The parsing will stop when the first mismatch is found Abelko Innovation 68 WebMaster Pro Reference Manual Hopefully some answer will also contain some useful information To use information the use right arrow assignment is used This compares with the left arrow assignment in the question compiler definition BYTE WORD RWORD and FLOAT keywords are allowed and statements are expected between the left and right parenthesis The difference is that the automatic variable DATA will have been assigned with the value from the frame The normal use of this construct is to assign a scaled version of DATA to a public or private variable 13 5 3 Floating point support in R4 0 In Release 4 0 with firmware 2 4 2 FLOAT support has been extended New keywords interpret and generate IEEE floating point values with different byte order FLOAT byte order ABCD native byte order RFLOAT byte order DCBA Reversed byte order BSFLOAT byte order BADC Byte swapped order WSFLOAT byte order CDAB Word swapped order 13 5 4 TIMEOUT The last part of a telegram definition is the timeout This is the number of milliseconds the GFBI will wait for a reply before giving up 13 6 MODBUS Example MODBUS is a standardized protocol on RS
58. a GPRS modem Will return Invalid data error message if no modem is present TEST_EMAIL Sends a test alarm email Abelko Innovation 114
59. an acronym for Cyclic redundant check and is basically a more advanced and better way to detect errors than a simple checksum Many protocols use CRC All CRC calculations used are based on the same algorithm The main difference between them is the so called polynomial or poly they use Disregarding the theory behind it the poly is just a number that goes into the algorithm Some numbers are better than others and they are standardized Several numbers are in use partly because there is a difference in what they are good at Some works better for long messages some for short and there is differences in the type of errors and the type of data they are good at The basic thing is that the POLY must be known The next thing that one must know is the start value the INIT of the CRC One can start with zero or all ones or sometimes some other number In communication devices CRC calculations are done very often It is therefore sometimes very important to optimize Because of that some implementations of CRC uses reflections of data Use the keyword REFIN if the input bytes are reflected or REFOUT if the output bytes are reflected Some implementations XOR the output value with another value before it is presented Such a value can be defined with XOR As with the other checksums the sum can be swapped and contain a skip section This has nothing to do with the CRC algorithm but rather with the protocol itself 13 7 2 Examples Here a
60. are displayed but also which coordinates can be selected graphically Abelko Innovation 28 WebMaster Pro WMPro Reference Manual 7 Databases 7 7 Introduction Databases and database emails are described in the user manual chapter 10 and how to add things to databases is described in chapter 5 The user manual does not describe how to use the database menu under advanced which will be described in the next section A database WMPro is a functionality that can store selected channel values at regular intervals in a circular non volatile buffer and present the information stored in the buffer in different ways In WMPro there are three databases and many web pages and tools will not work unless the short time database hour database and day database are defined The Goliath platform however allows up to six databases to be defined Each database can store up to 50 channels The memory area however is limited More channels means shorter history An internal buffer size limits the maximal history shown to 8000 time points The total available memory is distributed among the databases More databases thus mean less data in each Each database also needs a scrap buffer so more databases actually means less total memory for guaranteed database storage WMPro users are not recommended to play with the database definitions directly 7 2 Settings Advanced Databases View Databases DB
61. asured resistance for thermistor sensor Three parameters are used to define the sensor RO is the resistance at temperature TO Beta is a thermistor type dependent parameter The temperature is calculated according to T Beta TO Beta In R RO TO MathPar1 RO MathPar2 TO MathPar3 Beta code if Chn MathParl i 0 Denom Chn MathPar3 i Chn MathPar2 i log Chn Value i Chn MathParl i Else Denom 0 if Denom 0 Chn Value i Chn MathPar3 i Chn MathPar2 i Denom Ploynomial The polynomial mathematical function calculates a value using a second order polynomial defined by parameters a b and The value is calculated according to a bx cx where x is the input value This can be used for conversions of measured values from sensors MathPar1 a MathPar2 b MathPar3 code float x Chn Value i Chn Value i Chn MathParl i Chn MathPar2 i x Chn MathPar3 i x x Hourmeter The hourmeter function counts the time in hours that the monitored channel is higher than a reference value The main use of this function is for measuring running hours on digital inputs or outputs Many other uses are possible MathPar1 Limit MathPar2 MathPar3 Counter value code if Chn Value i gt Chn MathParl i Chn MathPar3 i Chn MathPar3 i 0 0002777777777777777777777777777 Chn Value i Chn MathPar3 i Abelko Innov
62. at it will never automatically become ready to send telegram identifier In order for these statements to work the telegram setting may not be set to inactive or one second When a telegram sent using a SEND command gets a good reply the telegram timer is reloaded with the telegram setting It will thus be automatically repeated if not SILENCE or SEND is called before the timer runs out Normally when a telegram fails i e did not get a good reply it is marked for immediate retransmission Using SEND and SILENCE statements this can be prevented The iterator in the example below calls either SEND or SILENCE every second The SILENCE statement stops any retransmissions This can be used to avoid unwanted communication attempts with devices that may or may not be connected The example calls SEND only once every minute the first second every minute causing the Read telegram to be sent once every minute The preparation delay and possibly message queuing if more devices or telegrams are active makes the exact timing for when the telegram is actually sent unknown Abelko Innovation 79 WebMaster Pro WMPro Reference Manual GROUP Example OF MAX 1 DEVICE TYPEID 11043 SELECT ALL TERATOR Update ALIAS BEGIN SEC 0 THEN SEND Read SILENCE Read tz a UO 5 Another use of the SEND
63. ation 21 WebMaster Pro 8 MPro Reference Manual Change DB The Change DB mathematical function is always used together with a database The channel value is the difference between the value at the last database save and the current value If MathPar3 is zero the mathfunc is updated every second else it is updated only when the database is updated The intended use for this function is to monitor the daily changes of a counter or an hour meter Connecting a channel with Change DB to an energy counting channel and putting it the day database will enable you to record how much energy used each day MathPar1 Last channel value MathPar2 Last change MathPar3 Hold last change code if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath if Chn MathPar3 i 0 running Chn Value i Chn Value i Chn MathParl i else Chn Value i Chn MathPar2 i Manual Override Manual Override adds the channel to the Manual Override menu allowing a user to override any value set by a script or other source When manual override is activated the channel will be assigned values just as normal but when read the manual override value MathParl1 will be returned instead of the true channel value There is a time limit for the manual override When activated a timer starts and when it times out manual override will be automatically disabled When disabled automatically or by user t
64. be of different types but all variables are treated as floats and all operators work with floats Abelko Innovation 42 WebMaster Pro WMPro Reference Manual There are no loop controls in the language As the script itself is executed in an endless loop they are not absolutely necessary They are not part of the language as they constitute an uncertainty in how long time they will need to execute and a risk of being or becoming endless There are no functions or procedures in the language nor explicit global variables Subroutines exist and channels may be used as global variables Scripts are stored as source code and are compiled at start up every time The initiation parts of an application script are interpreted i e performed at the same time as the syntax is checked The rest of the script that are to be executed later and possibly repeatedly is compiled into a binary format in a RAM area The compiler has no error recovery It will stop compiling when an error is found Separate user scripts are compiled separately and an error in one will not prevent already compiled scripts from executing 10 3 How to read a syntax graph The syntax of the script language will be described using syntax graphs This section is dedicated to explain how to read and interpret these graphs Below is an example from the initialisation of operator panel menu structure menurow submenu To be readable and printable the graph is divided i
65. bers smaller than 500 you ensure that the network and other basic settings are not changed To copy something more specific keep only the specific parameter numbers you need in the file In the chapter on getparx there is a table where you for instance can read that all parameters starting with 18xx regards overview pages To copy only the settings for the overview pages leave only these parameters in the file If you wish to be even more specific and only copy the settings for overview 1 select only rows with where the x dimension is one Note that the actual image file is not stored in the parameter bank 19 8 1 The parameter bank edit interface If it is only a few parameters that are to be copied there is a user interface accessible on the system file manager page CONFIGURATION BACKUP PAR contains all settings except controllers graphical programming and scripts Save a copy as backup For advanced configuration edit click here Click on the word here under CONFIGURATION Abelko Innovation 108 WebMaster Pro WMPro Reference Manual Parameter window RW F p1800x0y0z0 Overview 1 Overview 2 Overview 3 Overview 4 0verview 5 RWE p1801x0y020 1 2 3 4 5 RWE p1802x0y020 60 60 60 60 60 Update What you get is a text window where you can paste and edit parameter lines Press update to transfer them to putpar par Putpar par is a virtual file and is it never stored in flash memory as script
66. channel value multiplied with the factor parameter to the total sum If the absolute value of the total sum is higher than the limit parameter the sum value is set to the limit A limit of zero means no limit The sum function is a time discrete integrator It can amongst other things be used as integrator in a controller using the Limit parameter for antiwindup MathParl MathPar2 Factor MathPar3 Limit zero means unused code Chn MathParl i Chn MathParl i Chn MathPar2 i Chn Value i if Chn MathPar3 i gt 0 amp abs Chn MathParl i gt Chn MathPar3 i if Chn MathParl i gt 0 Chn MathParl i Chn MathPar3 i else Chn MathParl i Chn MathPar3 i Chn Value i Chn MathParl i Sum DB Same function as Sum but is reset to zero when stored in database Can for instance be used to store cumulative errors in database or on time for a digital signal MathPar 1 MathPar2 Factor MathPar3 Limit zero means unused Abelko Innovation 18 WebMaster Pro WMPro Reference Manual code Chn MathParl i Chn MathParl i Chn MathPar2 i Chn Value i if Chn MathPar3 i gt 0 amp abs Chn MathParl i gt Chn MathPar3 i if Chn MathParl i gt 0 Chn MathParl i Chn MathPar3 i else Chn MathParl i Chn MathPar3 i Chn Value i Chn MathParl i if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath
67. chapter 2 to 9 concerns details about all the functionalities of the WMPro Under Settings Advanced are several menus that are not fully explained in the user manual Even for functionalities that are explained in the user manual there still may be details that are not addressed For all functionalities where it is applicable a definition table with parameter numbers is included The parameter number is the key to access information when using OPC or writing new web pages or specialized software that communicates over http The second main section chapter 10 to 18 deals with the script language This is the base for all customized functionality in WMPro How to write scripts is not explained in the user manual but the reference manual hold all details The script section is written to be more readable than the first section but do not expect a textbook on programming The reference manual will explain all possibilities but expects the user to find out what to use it for There are some examples but look in the collection of application examples on the Abelko home page for more Chapter 19 is the third main section and deals with the parameter bank and how to access information in the WMPro There are tables of parameter numbers in the first section The third section will teach you what to do with them Abelko Innovation 7 WebMaster Pro WMPro Reference Manual 2 Channels 2 1 Introduction The conceptual unit of a channel is fun
68. ctly but with routines and other script elements as objects The interface is opened by clicking the snippets button ROUTINE ExampleCtrl On Off pulsing controller for electric radiators Close DEVICETYPE BrunataNet DEVICETYPE Komfortgrvare Insert from File DEVICE Initialisation GROUP Dataoppsamling GROUP ComfortSensors sam in GROUP ActiveSensors GROUP DataoppsamlingStat Delete Snippet ROUTINE RadioTemp Upp Down Apply Alias Type Description Connection All the script objects in user script three are listed in the main window If there is a comment like for the ExampleCtrl routine from chapter 11 1 and 11 3 it will be shown in this window If a routine is selected in the main window all aliases will be shown in table at the bottom half of the window The alias name and type is listed in the first columns If there is a comment on the alias row it will be shown in the column labelled Description The rightmost column shows the name of the channel or other object the alias is connected to Abelko Innovation 59 WebMaster Pro WMPro Reference Manual EVICETYPE BrunataNet DEVICETYPE Komfortgivare DEVICE Initialisation GROUP Dataoppsamling GROUP ComfortSensors GROUP ActiveSensors GROUP DataoppsamlingStat ROUTINE RadioTemp ing controller for electric radiators m Close pame ee as Insert from File Save to File
69. d encrypted PN_PPPMODE 217 PPP mode PN_PPPCHAPPASSWORD 218 Chap password encrypted PN DNSSERVERI 219 DNS server first alternative PN DNSSERVER2 220 DNS server second alternative PN DNSSERVER3 221 DNS server third alternative PROXYSERVER 222 Proxy server PROXYREMOTEACCESSNAME 223 Proxy remote access name PN PROXYREMOTEPASSWORD 224 Proxy remote password encrypted PROXYKEEPALIVEINTERVAL 225 Proxy keep alive interval seconds PN PROXYONLINE 226 Proxy server is online read only PN PORTALSERVER 228 Portal server PN PORTALID 229 Unit identification number for portal read only PN PORTALUPDATEINTERVAL 230 Update interval for portal seconds PN PORTALUPDATED 231 Portal updated read only SMTPSERVER 233 SMTP Outgoing mail server Abelko Innovation 111 WebMaster Pro Reference Manual SMTPPORT 234 SMTP Port number PN SMTPRETURNADDRESS 235 Return address in mails PN SMTPRCPT 236 PN SMTPCLIENT 259 SMTP client name PN SMTPMIMEACTIVE 260 Use MIME default 1 APPSCRIPTNAME 3000 Application script name APPSCRIPTINFO 3001 Application script info text APPSCRIPTVERNR 3002 Application script version number APPSCRIPTSWREQVERNR Application script required lowest firmware version PN USERFILENAME 3200 User script file names x to 6 79 17 Command parameter 5 Among all the parameters
70. damental to the operation of a WMPro A channel holds and channels the flow of information in a WMPro It can be connected to an input or an output or to another channel and in can perform mathematical operations on the data The channel value is a floating point value but the channel is also associated with a name a unit mathematical parameters and options and a set of flags Other systems in the WMPro get information from and put information to channels No other system works directly on hardware inputs and outputs A list of all 200 channels in a WMPro is accessible under Settings Advanced Channels This list is colour coded to make it easier to identify how the channels are used Unused channels are white Channels used by scripts are blue Channels that have been edited by a user but are not used by a script are yellow A red colour indicates that the channel is used by a script but has not been edited When edited and given for example a name it will change to blue 2 2 Definition Below is a table describing the complete set of information that defines a channel and the corresponding parameter numbers Name Type Comment Parameter Name String 32 A name p501 Unit String 8 A unit name 502 Scale float Scale factor 503 Offset float Offset value p504 Connection type byte Type of connection p505 Connection number byte Connection instance number p506 Value float The cha
71. e presented in the table below Parameter bank name Number Description PN VERNRI 1 Version numbers z Bootloader z 2 Firmware z 3 Web pages z 4 Application script PN_COMMAND 5 Explained in separate chapter PN_CURRENTACCESSNAME 9 The login name used PN_COMPILETIME 10 Firmware compile time PN_CLOCK 14 Current time PN_TIMEZONE 16 Timezone adjustment in minutes PN_MODNAME 21 Module name PN_MODTEXT 24 Module address PN_ETHERNETMACADDRESS 200 MAC address PN_ETHERNETDHCPACTIVE 201 DHCP active for Ethernet interface Abelko Innovation 110 WebMaster Pro WMPro Reference Manual PN_ETHERNETIPADDRESS 202 IP address for Ethernet interface PN_ETHERNETSUBNETMASK 203 IP subnet mask for Ethernet interface PN_ETHERNETGATEWAY 204 Gateway for Ethernet interface PN_PPPDHCPACTIVE 205 DHCP active for PPP interface PN_PPPIPADDRESS 206 IP address for PPP interface PN_PPPSUBNETMASK 207 IP subnet mask for PPP interface PN_PPPGATEWAY 208 Gateway for PPP interface PN_PPPMODEMINIT 209 Modem initialisation string PN_PPPBAUDRATE 210 PPP baudrate PN_PPPPHONENR 211 PPP phone number PN_PPPTIMEOUT 212 PPP Timeout seconds PN_PPPDCDTIMEOUT 213 PPP Timeout for DCD modem signal seconds PN_PPPREMOTEACCESSNAME 215 PPP Remote access name PN_PPPREMOTEPASSWORD 216 PPP Remote passwor
72. ecccsesesseaececccscseseaececececsessaaeeeceesesensaaeeeeecs 84 15 4 AEACOM GROUPS eet cR I 85 16 MA RILEVHORIS NUR 86 16 1 INTRODUGCTION Arotenecte a hee E 86 16 2 WMSHARE TYPE 8 2 00000000000000000000000000000000000000000 86 17 DEVICEINITIALISATION 553850 87 171 cete tae ERE E rt aede b RO PRI RO eO ide 87 17 2 TELEGRAM UPDATE INTERVAL CODES 88 17 3 Ie DEI 88 18 APPLICATION SCRIPTS 5 eese eerie ein 89 18 1 INTRODUCTION Ta 89 18 2 APPLICATION SCRIPT 8 0 12 011 110000000000000000000000000000000 eset nean annee 89 18 3 DEFINITIONS iicet e REIR ERE ER RE AP ET RENE PUE eG pepe 90 1634 AVAGO RERO E 91 18 3 2 Parameter eet 91 18 3 3 Constant definitions cene deed te eie 92 18 24 Channel definitions i i tb et td deret ve i te vestes 93 15 325 Curve definitions 5 i eee tee teste ye bcd 96 18 36 Alarm definitions eee etia e etre Lecta ave bi dere Lee eene ed 97 15 3 7 Database defines eee eee eet
73. enamed a b and c The flags cannot be edited from the form as they are automatically handled except for the Backup flag Normally a channel starts with the value zero after boot Setting the Backup flag to Yes means that the channel will use the last stored value instead The channel value is stored when the channel is edited by a user and in a backup process once every hour This flag should normally be set to No As channels are used in normal cases the initial value will be overwritten before it is used and setting the flag to Yes makes no difference Abelko Innovation 9 WebMaster Pro WMPro Reference Manual 2 3 Connection A channel can be connected to an input or an output or it can be unconnected The connection type number decides the type of connection The connection number decides which IO of the type the channel is connected to Val Type In Out Comment and connection numbers 0 None Not connected 1 DIN Digital inputs 1to8 DIN1 to DIN8 9 to 16 correspond to T1 to T8 used as digital inputs 2 DIN_F IN Digital frequency inputs 1 to 4 DINI to DIN4 3 AIN_U IN Analogue voltage inputs 1 to 4 AIN1 to AIN4 4 AIN_I IN Analogue current inputs 1 to 4 AIN5 AIN8 5 AIN_R IN Resistance measuring inputs 1 to 8 to T8 as temperature inputs 6 LED OUT LED outputs 1 to 32 are LEDs on the front panel card named LD1 to LD32
74. er in which updates occur can be important All channel updates starts with the lowest number channel first i e from 1 and upwards This is important for instance when a channel has another channel as input If the connected channel has a higher number the value will be one second old Abelko Innovation 10 WebMaster Pro WMPro Reference Manual When scripts and alarms and other parts of the system are involved it may be important to know the update order for all systems The updates are synced with the IO updates but executed in another thread When the signal comes that the updates are to start the following things are performed 1 OA eB 7 Input channels updated The application script is executed The user scripts are executed Output channels are updated Alarms are updated Calendars are updated Databases are updated If signal latency is important it may be good to know in which order the IOs are updated The analogue inputs are read one at a time throughout the interval of a second This is the order in which the IOs are updated starting at the one second periodic interrupt 1 8 eo SS AINI and T1 are measured Frequency measurement is updated AIN2 and T2 are measured DINI to DIN8 inputs are measured AIN3 and T3 are measured AIN4 and T4 are measured SYSTEM UPDATE STARTS AINS and 5 are measured DOUTI to DOUTS are updated AIN6 and T6 are measured AOUT1 to AOUTS a
75. erations in the script language resulting in the value true will be represented by the value one 11 3 2 Infix operators Infix operators work on two operands and is placed between the two operands In an expression with infix operators precedence is important 4 2 2 is 4 and not 1 because the operator has higher precedence than The table below lists all infix operators with highest precedence first Operator Boolean result Comment XOR X Exclusive or OR X AND X a Power x y is the same as x Multiplication Division MOD Modulus 11 MOD 5 is 1 Subtraction a Addition lt gt X Not equal lt X Smaller than or equal gt X Bigger than or equal lt X Smaller than gt X Bigger than X Equals Operators with a Boolean result will return either one or zero Note that the NOT operator has higher precedence than XOR 11 3 3 Parenthesis and memory requirements The syntax allows the use of parenthesis in expressions 4 2 2 is 1 Use parenthesis when it is required when it makes the expression easier to understand and when there are doubts on how the precedence works There is no optimisation during compilation of a script Expressions will be stored and evaluated as they are written When they are stored in binary form it is the meaning of each operator and operand that is stored not the text itself A plus operator takes only one byte i
76. f several values they are separated with semi colons when they are presented Abelko Innovation 103 WebMaster Pro WMPro Reference Manual g Debug menu WMPro Netscape Browser 192 168 0 24 frame htm i99 asf 4 http 192 16 4 aoliath htm http 192 16 4 a0liath htm Ml Debug menu P3 webbradio Sveriges Radio Parameter 514 1 020 Mae Get Reset FTP applet backup par system log Database x z Send file Filename in WMPro putpar par Username Password File to send Browse Send 0 0 0 0 0 0 11 0 0 0 0 1 1 01 Done Trying to get p501x0y02z0 all channel names will fail because this is too much data for getpar ssi We will later show how this information can be received using the getparx ssi instead Parameters can also be written using the test page Type a value in the value field and then press Set If successful the parameter bank should reply with PUTPAR OK Be careful not to write in parameters unintentionally 19 3 Getpar ssi Getpar ssi can be used directly in the address field of a web browser Type for example http 10 0 48 94 getpar ssi pararg p501x1y0z0 The browser will believe it is opening a file named getpar ssi and the file will contain the name of channel 1 19
77. g port It is also possible to see them in the system log file It should only be used temporarily for debugging Filling the system log file with script printouts may hide other more important system printouts debugprint Conr oC Ce sees pE joerc 4D HG 11 2 5 Call statements The call statement executes the referenced subroutine In a routine only other routines can be called In a procedure both other procedures and routines can be called routine call In user scripts calling is less useful as all defined routines will be executed in the order they are defined In later chapters groups and iterators will be defined Group iterators must be called from a routine as they are not automatically executed 11 2 6 Acknowledge The acknowledge statement can be used to acknowledge all alarms acknowledge statement ACKNOWLED GE The intended use is to make it possible to reset alarms by pressing a button connected to a digital input Use it with care 11 2 7 Disable and enable alarms A new feature in the 3 1 release is the possibility to disable and enable alarms from scripts When disabled the alarm can no longer become active If it is active when disabled it will become inactive if it is set to automatic If it is set to be acknowledged it will still be necessary to acknowledge it ENABLEALARM enables an alarm previously disabled with DISABLEALARM The intended use for these commands is to make it easier to disab
78. gnificance The value changes only every 16 th second year 2006 and as the number grows it will change even more seldom With the release of WMPro 2 0 six new time functions are available They return different parts of date and time as presented by the real time clock RAND and RANDN return random numbers RAND returns a uniformly distributed random number between 0 and 1 RANDN returns numbers with the approximate N 0 1 normal distribution 11 3 5 New expressions in R3 1 In R3 1 a new expression is available to check whether a channel is in manual override or not ismanualoverride expression ISMANUALOVERRIDE gt If the channel has the manual override math function set and manual override is active the Show3 flag is set the expression returns one Otherwise it returns zero 11 3 6 Curves Curves can also be called as functions The curve identifier should be followed by an argument expression in parenthesis The curve function looks up the interpolated y value corresponding to the argument x value 11 3 7 Examples and error handling Below is a table with example expressions and what they evaluate to X y and z are variables assigned the values 4 2 and 100 x 4 000000 y 2 000000 z 100 000000 x yt0 5 z 66 000000 SIN PI 2 0 1 000000 FLOOR 11 5 2 000000 11 MOD 5 1 000000 2 0 000000 2 1 000000
79. h references to channels variables parameters and curves expression unary operator constant res_function res_const This syntax graph is somewhat complex yet expressions are quite intuitive Starting in the middle section with the simple number There is not much point in showing a syntax graph for numbers They consist of the digits 0 to 9 and optionally a decimal point followed by more digits Channels can be referred either by an alias or define name or the CHANNEL keyword with the index in angle brackets as shown in alias examples The same is true for parameters except that the keyword is PARAMETER Variables and constants are referred to by name res const stands for reserved constant and are names that represents a constant value defined in the language itself This category has only one member PT 11 3 1 Unary operators unary operator NOT An unary operator is an operator that operates on a single operand The operand is to the right of the operator The minus sign will negate the value standing on the right side of it This means that writing 1 23 becomes syntactically correct Abelko Innovation 52 WebMaster Pro WMPro Reference Manual The NOT operator is a Boolean operator All Boolean operators treat a nonzero value as true and zero as false The not operator will make nonzero values zero and change zero values to the nonzero value of one All Boolean op
80. he true channel value will be returned again as in normal operation Manual override is always disabled after reset Activation and deactivation of manual override is done through the Show3 flag MathParl Manual Value MathPar2 Time Limit MathPar3 Time Counter Abelko Innovation 22 WebMaster Pro 8 MPro Reference Manual 3 Parameters 3 1 Indroduction A parameter is in some senses similar to a channel but unlike a channel a parameter holds static data The value of a parameter can only be changed by a user with operator or config rights It is used to parameterize a controller or other script A list of all 100 parameters in a WMPro is accessible under Settings Advanced Parameters This list is colour coded just as the channels list is to make it easier to identify how the parameters are used Unused parameters are white Parameters used by scripts are blue Parameters that have been edited by a user but are not used by a script are yellow A red colour indicates that the parameter is used by a script but has not been edited When edited and given for example a name it will change to blue 3 2 Definition Below is a table describing the complete set of information that defines a channel and the corresponding parameter numbers Name Type Comment Parameter Name String 32 A name p900 Unit String 8 A unit name p901 Value float The channel value p902 Decimals byte Number of
81. hecksum to be modbus style CRC The swapped and skip keywords can be used here to The CRC8 and CRC16 keywords starts general CRC definition This is explained in detail in section 12 7 If the checksum is not placed last in the telegram use the POSTBYTES keyword to define how many bytes comes after the checksum Abelko Innovation 67 WebMaster Pro WMPro Reference Manual 13 5 Telegram definitions A device type definition can have up to ten telegram definitions Each telegram defines a string that is used in the settings page for external devices where the user can set how often if at all a question should be asked 13 5 1 Question compiler definition The question part of a telegram definition states how the frame sent to the external device should look like Each byte of the frame must be defined This is done assigning values to a data array DATA n represents the n th byte in the frame It can be assigned to a value using colon equals assignment The simplest form of assignment is using HEX where the byte is assigned a constant hex value The HEX function only accepts a single byte value described by two letters A to F must be capital when used The BYTE WORD and RWORD takes an expression as argument The only identifiers in scope are the variables and parameters defined in the DEVICETYPE but calculations can be made on them With the BYTE keyword the value is typecasted to a char and assigned to the byte
82. her snippets the order is also important A reference to something that has not yet been defined renders a syntax error Abelko Innovation 61 WebMaster Pro WMPro Reference Manual 13 GFBI Type Definitions 13 1 The General Field Bus Interface The DEVICETYPE definition defines a class of external devices on RS485 using the General Field Bus Interface GFBI GFBI is general but with limits It can handle protocols on the RS485 that follows these criteria e The WMPRo is master slaves are quiet unless they answer a question from the master e size of a correct answer to a specific question is constant and known e Data is in binary form no strings e The checksum or crc method can be handled by GFBI Should be true for most protocolls e The units accepts an intertelegram gap of 3 5 characters silence as legal The communication speed is between 300 and 115200 bps Different device types using different protocols can be connected at the same time provided that they do not interfere with each other Care must also be taken in each system so that the computational power of the WMPro is sufficient to handle all connected devices as expected The GFBI handles telegrams The device type definitions define how a question telegram should be compiled The GFBI motor sends this telegram on the RS485 line and starts to listen for an answer of the correct size If one is received within the timeout period it is parsed usi
83. iators CHANNEL 33 Zone 1 Radiators I PARAMETER 24 5I factor SetValue PARAMETER 25 Room temperature setvaluee Interval PARAMETER 26 Cycle time PowerLimit CURVE 1 0utdoor gt Power limit Stop ALARM 1 55 alarm VAR Timer Power BEGIN Timer Timer 1 IF Timer gt Interval THEN Timer 0 ENDIF Power Power I SetValue RoomTemp IF Power gt PowerLimit utTemp THEN Power PowerLimit OutTemp ELSIF Power lt 0 THEN Power 0 I EID TEs bud Messages Position Row 579 Col 17 File stored System is rebooting Important keywords such as begin end if then etc are shown in blue and made bold Other script keywords that appear are coloured green Note that the script interpreter is case sensitive and that all keywords must be typed in capital letters Colour coding work as you type so if a keyword does not become blue or green when ready it is probably misspelled Identifiers and operators are black To increase readability Identifiers should be given names including lowercase letters Numbers are pink 6699 There is no example of this in the script above but strings always enclosed by marks are red Comments are coloured grey 12 2 Inserting Aliases Above the editing window there are to drop down lists and a button labelled Insert Alias When you come to the alias section of a routine you can type the alias name and a space Then select which ki
84. ier name will be in scope in routines and procedure defined later and can be used in expressions Most define statements can include flag initialisation but these have been left out or only hinted for simplicity in the syntax graph Flags will be explained in a separate section 18 3 1 Initiators Most define statements will be able to initialise system parts such as channels and parameters This initialisation can be conditional There are three initiator operators initiator The initiator stands for hard unconditional initiation At every start up the left side entity will be assigned the right side value A user can change the settings but they will be overwritten at the next boot sequence If you wish to let the user change things use the initiator instead The assignment will take place only if the user has not changed some part of the entity When a user changes a setting from the web page an edited flag will be set This flag is common for all individual settings of a single channel parameter and alike These flags can be reset system wide from the web pages The initiator is the weakest one Assignment will only take place if the entity has not been used before Just as there is an edited flag there is also a used flag This flag is set as soon as a Script defines it or a user activates it 18 3 2 Parameter definitions A parameter is defined and initialised using the following syntax The tree is a continuat
85. ight statements will be presented in the following sections 18 4 2 Assignments Procedures have more assignment possibilities than routines assignment 2 expression g 1 It is possible to assign values to scale and offset and to math function parameters 18 4 3 The PUTPAR statement putparst atement PUTPAR Abelko Innovation 101 WebMaster Pro WMPro Reference Manual PUTPAR makes it possible to assign values to any assignable parameter in the parameter bank Read the chapters about the parameter bank to understand how to use PutPar The first argument to PUTPAR is the parameter number The second third and fourth arguments are the x y and z numbers The final argument that can be either numeric or a string is the value to be put to the parameter There is no guarantee that the parameter bank will accept the call Both parameter numbers and the value may cause the parameter bank to object Example PUTPAR 1507 1 0 7 0 Putting this row in the boot section of an application script will disable the operator panel 18 4 4 Call statements In procedures calls can be made to other procedures as well as to routines 18 4 5 Update The update statement is currently only experimental Use is discouraged and future support is not guaranteed update statement Curie HG The boot procedure is executed once before any routines of the application section or
86. in several places in the script it is thus better to calculate once and store in a variable than like in the example invoke it directly several times Abelko Innovation 82 WebMaster Pro WMPro Reference Manual 15 AeACom Scripts 15 1 Introduction AeACom is a protocol used on the expansion port RS485 line The main feature of AeACom is that it can be management free AeACom devices has much like Ethernet devices a factory set unique address Therefore it is not necessary to set and manage addresses manually It is also possible to build systems with AeACom that works instantly when devices are plugged in on the bus The third benefit of AeACom is that it can guarantee communication time intervals for individual devices On an AeACom bus the WMPro is master At regular intervals it sends out a synchronisation frame containing information about the number and size of time segments used in a bus cycle The sync frame also contains information about free time segments Newly connected devices randomly select one of the free time segments and use it to report to the master that it exists and what kind of device it is If the master acknowledges the device it will continue to use that time segment throughout the session When a new session starts with many devices connected there will be an arbitration period where all devices seek to find their own time segment This may take a few bus cycles depending on the number of devices and
87. in the parameter bank there is one that is a little bit more special than the others Parameter number five is a parameter that cannot be read and does not store a value This is a parameter you write commands to Commands that the WMPro will perform http 10 0 48 94 putpar cgi p5xOyOzO RESET The example above writes a reset command to the WMPro The WMPro returns a web page containing PUTPAR OK as a receipt that the parameter write and command was understood Then it performs a controlled restart For some commands the z dimension is used to pass an argument for the command The table below lists possible commands and arguments Command string 7 Explanation and arguments Initialisation of the parameter bank with default values 001 Default init RAM param 002 Default init EEPROM FLASH param with protection level lt 1 003 Default init EEPROM FLASH param with protection level lt 2 004 Default init all EEPROM FLASH param WARNING Do not use this It destroys calibration serial number and other vital information Same as 001 and 00 Same as O and reset Abelko Innovation 112 WebMaster Pro 8WMPro Reference Manual APPINIT CLEARDBS CLEARPRG ACKEVENT Q ACKALARM Abelko Innovation 001 Check 002 Execute 003 Update 004 Create 01 Verbose version of the commands 1 Same a
88. ines There are also size constraints and memory constraints that can prevent syntactically correct scripts from compiling Note The operator panel menu definitions used in the example are no longer a part of the script language Abelko Innovation 43 WebMaster Pro WMPro Reference Manual 11 User Scripts User scripts are scripts that are executed every second WMPro has defined three different user scripts with separate program memory but they are all defined in the same file user script el The number the script declaration states which of the three user script storage places to be used Between the BEGIN and END statements several routines and other definitions can be declared Each routine will be called every second in the same order as they are declared The order between the scripts is such that the routines in the application script are executed first then user script one two and finally three USER SCRIPT 3 BEGIN END If two user scripts are declared with the same number the second will overwrite the first When using the built in script editor the line USER SCRIPT 3 BEGIN and END will automatically be added and are not shown You can start writing routines directly Routines are the basic script program element The other possible program elements shown in the synta
89. ion of the syntax tree started in the beginning of the chapter PARAMETER DECIMALS Abelko Innovation 91 WebMaster Pro WMPro Reference Manual The things you can initialise are the same things that can be set from the web pages All of these things are optional Flags is common to many entities and will be explained separately DEFINE RefVal AS PARAMETER 1 NAME Setpoint UNIT cm DECIMALS 2 VALUE 42 END DEFINE X AS PARAMETER 2 END The names RefVal and X in the example above are identifiers that can be used in expressions later in the script 18 3 3 Constant definitions CONSTANT E The constant definition is the most simple one It is just an alias for a number D NE TheAnswer AS CONSTANT 42 Abelko Innovation 92 WebMaster Pro Ww MPro Reference Manual 18 3 4 Channel definitions Whereas a constant was simple channels are a little bit more complicated The name unit scale offset and decimals part is not complicated The source statement is also not different from the web pages The only things that will require extra explanation are the math functions with arguments define CHANNEL B SCALE B OFFSET DECIMALS Abelko Innovation 93 WebMaster Pro 8WMPro Reference Manual STD
90. l math parameters Each of the available options will be explained briefly Abelko Innovation 32 WebMaster Pro 8WwMPro Reference Manual 8 3 1 Text Header and Line Text header and line are simple summary rows For Text and Header a text is entered Line has no options It simply invokes a line Summaries ManualExample Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Summary settings Name Manual Example Add to view menu Yes m Update Row number Row type Information 1 Text Example of text 2 Header Example of Header 3 Line 4 None The resulting summary page looks like Manual Example Example of text Example of Header The page name is always shown at the top of the page Under that odd rows are given a blue background colour and even rows have white background The text row simply shows a row of text The header row displays a text in bold with a blue line under it The line row is somewhat obsolete since the alternating background colours were introduced It is basically a blank row 8 3 2 Image The image option will show a image provided that an image has been uploaded to the selected user file Manual Example Abelko Innovation 33 WebMaster Pro WMPro Reference Manual 8 3 8 Link A link row will put a link in the summary page Both an URL and a help text can be entered The help text is optional Edit Manual Example row 1 Select row func
91. l seconds MathParl MathPar2 Interval MathPar3 code if Chn MathPar3 i 0 Chn MathParl i Chn Value i reset if Chn Value i gt Chn MathParl i Chn MathParl i Chn Value i Chn MathPar3 i Chn MathPar3 i 1 if Chn MathPar2 i gt 0 if Chn MathPar3 i gt Chn MathPar2 i Chn MathParl i Chn Value i Chn MathPar3 i 0 else if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath Chn Value i Chn MathParl i RTD The RTD mathematical function can be used to calculate a temperature from a measured resistance for resistance dependent temperature detector Three parameters are used to define the sensor RO is the resistance at temperature TO Alpha is a material dependent constant The temperature is calculated according to T R RO RO Alpha T0 RO Alpha The formula is a first order approximation an can give significant errors far from TO for some types of sensors It is for example not very good for Pt1000 sensors MathPar1 RO MathPar2 Alpha MathPar3 TO code float ROAlpha ROAlpha Chn MathParl i Chn MathPar2 i if ROAlpha 0 Chn Value i Chn Value i Chn MathParl i ROAlpha Chn MathPar3 i ROAlpha Abelko Innovation 20 WebMaster Pro WMPro Reference Manual Thermistor The thermistor mathematical function can be used to calculate a temperature from a me
92. lds the length of the interval in seconds For each time point item there is one TimeStart and one TimeDuration TimeStart holds information on how long into the period the Time Control will change state to true TimeDuration holds for how long time thereafter it will remain true Abelko Innovation 26 WebMaster Pro WMPro Reference Manual The periodicity is based on the real time clock This means that if the TimelIntervall is set to one hour the interval will start when the real time clock passes an hour This also means that the Time Control might change state when the clock is set 5 3 2 Calendar The calendar time control type is used for nonperiodic time control For each time point DateStart holds an absolute time stored as seconds since 2000 01 01 00 00 00 when the control will become true and a DateStop for the time when it will stop being true 5 3 3 Week The Week type is periodic for every week Each time point consists of a WeekStart and WeekStop which are timpoints in a day The WeekDayMask masks out for which weekdays the timepoint definition is to be active Bit 7 of the bitmask activates the Weekday catalogue This enables the week schedule to take public holidays and other irregularities into consideration 5 4 Weekday Catalogue The weekday catalogue is stored in parameter 1712 The parameter holds up to 100 wekday replacements consisting of a date and day identifier pair like 2004 01 01 7 The number 7
93. le alarms that are not valid in certain operational modes such as when a machine is not running or to disable alarms for optional features that are not enabled Abelko Innovation 49 WebMaster Pro WMPro Reference Manual disablealarm statement Peen ji enablealarm statement Caan H 11 2 8 Set and Clear manual override A new feature in the 3 1 release is a possibility to set and clear manual override from scripts CLRMANUALOVERRIDE disables manual override for the argument channel This can be useful if there are certain states when stupid users should not be able to manually override your clever program clrmanualoverride statement CLRMANUALOVERRIDE DO HP setmanualoverride statement Csemanuncovenpe gt EEE HO HE SETMANUALOVERRIDE makes the interface symmetrical and maybe it will be useful to someone sometime The statements are equal to check and uncheck the manual override checkbox in the web interface 11 2 9 Comments To make comments use the sign The rest of the line will be treated as a comment ROUTINE StatementsExample ALIAS LeftEnd CHANNEL 17 Left end reached DIN RightEnd CHANNEL 18 Rigth end reached DIN GoLeft CHANNEL 25 DOUT GoRigth CHANNEL 26 DOUT TimeLeft CHA
94. lues The file backup par is a text file the parameter bank generates with all information from the parameter bank It can be written back to the virtual file putpar par to set values in the parameter bank This is used for system backup but by editing the file sent to putpar par it can be used for other purposes too 19 2 Parameter numbers Parameter numbers for many of the fundamental functionalities have been defined in the first section of the reference manual For all these the x dimension is used to specify the number of a channel parameter etc Setting the x parameter to 0 refers to all For parameters where the type is declared to be an array the z dimension is used to identify elements in the array For example p514x1y0z7 refers to the seventh flag the USED flag of channel one Setting z to 0 refers to the whole array You can normally not set to zero and use specific values for y and 2 Changing the goliath htm ending of the address field when surfing in a goliath to t_frame htm will bring up a test page This can be used to experiment with parameter bank numbers Fill in a parameter number in the Parameters field like 514 1 0270 and then press Get The page will then use getpar ssi to get the parameter from the parameter bank The result is shown in the window further down Messages from the parameter bank are shown at the bottom of the page The parameter we retrieved was all flags for channel one As this consists o
95. m statistic motor task execute ticks 103 System statistic parbank task execute ticks 104 System statistic parbank task period 105 System statistic rtxc not idle ticks 106 System statistic rtxc normalised idle count s 107 System statistic allocated heap size 108 System statistic allocated heap blocks 2 3 3 Unconnected channels Unconnected and output channels will not be updated with new values from an input Values can be assigned by scripts including graphical programmes or controllers or by an alarm as an action channel If not the value can be set manually in the user interface The channel value is however normally not saved and will be reset to zero when the WMPro boots It is possible to set a flag to preserve channel values Find more information in the flags section in chapter 19 2 4 Scaling When the channel is connected to an input the value from the input will be scaled using the scale and offset parameter of the channel Channel Value Scale Input Value Offset Outputs are scaled according to Output Channel Value Offset Scale When there is no connection scale and offset has no effect When a channel is assigned a value in a script or from an alarm this affects the value parameter directly with no scaling Abelko Innovation 12 WebMaster Pro WMPro Reference Manual 2 5 Mathematical functions A mathematical function is executed after an i
96. me stamp 7 4 Database Email Definitions Name Type Comment Parameter Name String 20 A name p1900 Type byte 0 On Time p1901 1 On Alarm DbsNr byte Database p1902 SendInterval Long int Send interval p1903 SendOffset Long int Send offset p1905 SendTrigAlarmNr Byte The alarm that can trigger a send p1906 SendLimit int Max number of rows in a mail p1907 Abelko Innovation 30 WebMaster Pro Reference Manual SelSelChnNr Byte array Database items in the mail p1909 String 47 Array of four email recipients p1910 array Flags word Flag array p1913 Each of the ten emails that can be defined can send a maximum of 20 channels The SelSelChnNr defines which channels to be included It is not however the channel number that is stored It is the number of the database SelChnNr that points to the channel Thus changing the selection of channels that are to be stored in a database may indirectly also affect the database emails Abelko Innovation 31 WebMaster Pro WMPro Reference Manual 8 Summary pages 8 1 Introduction The summary is a way to assemble and view channels settings curves and more that belong in a context under one costume menu under View The user manual has a basic explanation of how to make summary page in chapter 14 Here you will find a list of all the options when making a summary page 8 2 Basic Settings View Summarie
97. means Sunday and 1 would mean Monday The weekday catalogue can be edited as described in user manual chapter 9 3 The default weekday catalogue is unless something else is explicitly stated defined for Swedish holidays up to and including 2009 Copying a weekday catalogue can be done by extracting information from the backup par file Use the web interface to edit the weekday catalogue in one WMPro Retrieve the file backup par from the device and open it in a text editor Locate and copy all files starting with RWE p1712 to a new file To install the weekday catalogue in another WMPro upload the file to parameter bank This will only change the weekday catalogue in that device without changing any other settings The dates in the weekday catalogue may be entered in any order The latest date may be entered on the first row 5 5 Script notes When using script it is possible to get and use the state of a time control That should be no surprise It is also possible to get information about how much time it is left until it will change state This widens the range of possible uses of time controls One possible use with the TIMELEFT function is to have the time control define when a building is used and should be at daytime temperature A script can use TIMELEFT and start warming or cooling the building in advance where the exact starting time can be calculated from either outdoor temperature room temperature or some combinatio
98. n This will show a checkbox that is either checked or unchecked Unchecked corresponds to parameter value 0 and a checked box to the value 1 8 3 8 Edit channel There are four edit channel options each deal with different channel properties Row number Row type Information 1 Edit channel scale offset Temp 8 2 Edit channel name unit Temp 8 3 Edit channel math parameters Temp 8 Exactly how the edit channel math parameters row will look like depends on the math function of the channel Abelko Innovation 36 WebMaster Pro WMPro Reference Manual Manual Example text Edit channel scalevoffset Temp 8 Scale A Temp 8 Offset 0 Update Help text Edit channel name unit Temp 8 Name Temp 8 Temp 8 Unit bc Update Help text Edit channel math parameters Math function Polynomial Temp 8 a 246 009 Temp 8 b 0 2361 Temp 8 9 91e 06 Update Of special interest is the edit math parameters function for Hour meter math function Manual Example Edit channel math parameters Math function Hour meter Running time Counter value h 1000 04 Update This makes it possible to reset or set any time on an hour meter for example after service 8 4 Limitations of summary pages text in a summary page is stored in a common memory space This includes texts for headers text help texts and URLs The total amount of text for a summary page is
99. n of information Abelko Innovation 27 WebMaster Pro WMPro Reference Manual 6 Curves 6 7 Introduction Curves are a form of interpolating look up tables LUT How they work and are used is described in the users manual chapter eight They are basically used to translate one value along the X axis to another value along the Y axis Up to ten points can be used to define the curve These make up a piecewise linear function f x Values higher than the largest point X value or lower than the lowest point X value will be translated to the Y value of the closest point The value is not extrapolated from two last or first points 6 2 Definition Name Type Comment Parameter Name String 20 A name p1300 MaxPoint byte Number of defining points used p1301 LabelX String 20 X Axis label p1302 LabelY String 20 Y Axis label p1303 ValueX float array Array of point X values p1305 ValueY float array Array of point Y values p1306 MinValueX float X axis min limit p1311 MaxValueX float X axis max limit p1312 MinValueY float Y axis min limit p1313 MaxValueY float Y axis max limit 1314 Decimals byte Number of decimals shown for p1310 definition points Flags word Flag array p1308 The point values ValueX and are addressed trough the z values 1 to 10 Min and Max X and Y values are inactivated if set to zero The decimals setting will not only affect how coordinates
100. n MathParl i Chn MathPar2 i 0 Chn Value i Chn MathPar3 i Count over DB Same as Count over but is reset to zero every time the value has been put into a database MathPar1 Limit MathPar2 MathPar3 code if Chn Value i gt Chn MathParl i Chn MathPar3 i Chn MathPar3 i 1 Chn Value i Chn MathPar3 i if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath Count under DB Same as Count under but is reset to zero every time the value has been put into a database 1 Limit MathPar2 MathPar3 code if Chn Value i lt Chn MathParl i Chn MathPar3 i Chn MathPar3 i 1 Chn Value i Chn MathPar3 i if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath Abelko Innovation 15 WebMaster Pro WMPro Reference Manual Count pulse DB Same as Count pulse but is reset to zero every time the value has been put into a database MathPar1 Limit MathPar2 MathPar3 code if Chn Value i gt Chn MathParl i amp Chn MathPar2 i 0 Chn MathPar3 i Chn MathPar3 i 1 Chn MathPar2 i 1 else if Chn Value i lt Chn MathParl i Chn MathPar2 i 0 Chn Value i Chn MathPar3 i if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath Mean Mean calculates the mean value over a period
101. n the source code file but 14 in compiled binary form A pair of parenthesis also takes 14 bytes to store A constant value always takes six bytes in compiled form It will not matter if it is written as 1 or 1 00000000000000 The lesson from this is that it is good practise to write expressions in a precise manner Writing x 14 4 instead of x 3 5 will make the script interpreter execute the 14 4 division every time Abelko Innovation 53 WebMaster Pro BW MPro Refere nce Manual 11 3 4 Reserved functio ns It was stated earlier that there are no functions in the script language It is true that you cannot define your own functions but there are built in functions res function Kd Ec This is standard library functions and should not require many comments Angels are presented in radians The 51 positive and 0 if the argume seconds left to the next pred There are also a few functio TIME YEAR TIME MONTH TIME DAY TIME HOUR TIME MINUTE TIME SEC Abelko Innovation GN function returns 1 for negative arguments 1 for nt is zero The TIMELEFT function returns the number of icted state change of a time control ns that do not take an argument 54 WebMaster Pro WMPro Reference Manual TIME returns the number of seconds since 1 1 year 2000 This function is depricated and should not be used The problem with it is that a float cannot store that large numbers without losing si
102. nd memory 53 10 3 4 Reserved functions sss aede eee oe nire iade odi oie iae iet 54 712292 New expressions in R3 1 aed eee hee te dye totae redit ins reae ies 55 PESOS 55 11 3 7 Examples error handling esee nennen nennen renes 55 12 THE SCRIPT EDITOR issscsccocccieteesssvtecesesnsactsesvensesestooseacevescesecseuetessnescnsesvennsssacdsdenessesessusvessess 56 12 1 SYNTAX HIGHLIGHTING 2 bete bee ee Ele bete Ra eode ee aede 56 12 2 INSERTING ALIASES ied eter er ire Rete ees Eee de Yo dece edite eden 56 12 3 SAVING THE SCRIPT Reed eter rre Oe decies tees anes densa c dece ee t eere d 57 12 4 THE SNIPPETS INTERFACE 59 12 4 1 Editing aliases ii eee Ree e t LUE i e Ae pert e 60 12 4 2 Saving and loading Snippets eese nennen nennen eene nette 61 12 4 3 Moving and deleting Snippets sessi nennen rennen 61 13 5 62 13 1 THE GENERAL FIELD BUS 4 4 2 62 13 2 THE DEVICE DEFINITION sccccsessecesssececsescececeeceecsssaeeecsesaececseeeecsesaeeecseaeeeeennseeeses 62 13 2
103. nd of alias in the first drop down list and then the item in the second drop down list Abelko Innovation 56 WebMaster Pro WMPro Reference Manual Save Snippets Safety alarm ROUTINE Example 11 2 ALIAS YourIdentifier When you click Insert Alias the alias line will be finished for you Save Snippets Safety alarm ROUTINE Example 11 2 ALIAS YourIdentifier ALARM 1 Safety alarm The comment includes the name of the aliased object 12 3 Saving the script To save a script simply press save The file will be sent to the WMPro The WMPro will check if the syntax is correct and if it is the file will be saved and the WMPro will reboot When it starts again the new script will be active If however there is an error in the script the WMPro will return an error message instead of saving the file The error message is shown in the message window in the bottom Save Snippets ALARM Safety alarm Insert Alias ROUTINE ExampleCtrl 0n ff pulsing controller for electric radiators ALIAS OutTemp CHANNEL 1 Qutdoor Temp RoomTemp CHANNEL 2 Room Temp Radiators CHANNEL 33 Zone 1 Radiators I PARAMETER 24 5I factor SetValue PARAMETER 25 Room temperature setvaluee Interval PARAMETER 26 Cycle time PowerLimit CURVE 1 0utdoor gt Power limit Stop ALARM 1 Safety alarm YA
104. ng the reply definition Telegram settings accessible from the external device settings page decide the minimum delay between how often a specific question is asked Only one question can be sent to a specific device every second but GFBI can send question to many devices during the same second 13 2 The Device Type Definition 13 2 1 Overview Each device type has a name visible in web pages and a type number The type number is what truly identifies the definition and must be unique The script name also used is less important As mentioned before the definition holds a number of variables some with public names as parameters other with public names as values and some are only for script use The communication speed and checksum type is defined for all telegrams and then the telegrams themselves are defined Telegram definitions consist of a question compiler and an answer interpreter The web page interface limits the number of telegrams to ten each with a public name Abelko Innovation 62 WebMaster Pro WMPro Reference Manual 13 2 2 Syntax Below is the syntax graph for a device type definition devtype men a E PRIVATE E BAUDRATE number eauomarE oo 4 zsuMs ER pas Cos p POSTBYTES number Abelko Innovation 63 WebMaster Pro 8WMPro Reference Manual Where namedef has the following sy
105. nnel value p507 Decimals byte Number of decimals to display p508 MathFunc byte Type of mathematical function p509 MathPar 1 float Mathematical function parameter p510 MathPar2 float Mathematical function parameter 511 MathPar 3 double Mathematical function parameter 512 Flags word Flag array p514 Name and Unit are strings of maximally 32 and 8 characters respectively A channel value is normally displayed as name value unit like Outdoor temperature 16 2 9 The value of the parameter Decimals decides how many decimals to display when printing the value In the example this was set to 1 but may be 0 to 5 The other parameters of a channel definition are explained in the following sections The Flags parameter is explained in the chapter Flags as it is common to many systems in WMPro Abelko Innovation 8 WebMaster Pro 8WMPro Reference Manual How to use the channel numbers is explained in the section about the parameter bank Edit channel number 1 Channel name Temp 1 Channel value Channel unit Number of decimals Scale 1 Offset Connection type Temperature Connection number 1 Math function Poynomial b 0 2361 Cancel Delete OK The values of a channel definition can be edited when clicking a channel in the list The form renames and disables MathPar 1 to 3 as appropriate from the selection of MathFunc In the example above they have been r
106. nput or an output has been updated For channels with no connection the mathematical function is updated at the same time as channels with inputs The mathematical function makes calculations and replaces the channel value with a new value The three parameter called MathPar 1 to 3 are used both as input parameters to some mathematical functions and as state information holders for mathematical functions with a internal states Note MathFuncs for channels are not functions in the strictly mathematical sense of the word When a mathematical function stores states these states must sometimes be cleared This can be done from script but the most common usage is together with databases The database sets a flag that the triggers the reset Some functions come in two variants one to be used with databases and one to be used with manual or periodic resets States are stored before controlled reboots and once every hour If a power failure occurs up to one hour of information may be lost Below is a list of all available functions with parameter definitions and C code semantics Abelko Innovation 13 WebMaster Pro 83 MPro Reference Manual AR filter Auto regressive filter function The filter factor is between 0 and 1 where 0 means no filtering and 1 means complete disconnection AR Filter step respons for factor 0 5 0 7 0 8 0 9 0 95 and 0 99 St ES 1 0 8 1
107. ntax graph namedef SCIENTIFIC FLOAT The first string is the actual name The optional string within brackets defines a unit and the optional last keyword defines the formating when the value is printed Abelko Innovation 64 WebMaster Pro 8WMPro Reference Manual The syntax graph for a framecompiler and a frame interpreter follows framecompiler Abelko Innovation 65 WebMaster Pro WMPro Reference Manual 13 3 Example Below is an example for a definition of a device using a propriety protocol a KomfortEI41F from Abelko an apartment heat control unit DEVICETYPE KomfortEl41F NAMED KomfortEl41F TYPEID 1003 IS PARAMETER Id Address sbTemp Set back temperature PUBLIC inTemp Apartment Temp C 71 Zon1 c Z2 Zon2 G pee Z4 Zon4 C DI Digital Input Boiler HotWater PRIVATE Outdoor BAUDRATE 9600 CHECKSUM SUM8 TELEGRAM ReadStat NAMED R Stat IS QUESTION DATA 0 HEX 01 DATA 1 HEX FE DATA 2 06 DATA 3 52 4 5 DATA 6 HEX 00 DATA 7 HEX FF DATA 8 HEX FF ANSWER SIZE 24 DATA
108. nterface CONDITION defines the channel to be monitored the condition type and the limits DEF IN larmHighTemp AS ALARM 1 NAMI High temp MESSAGE The indoor temperature is high CONDITION AirTemp gt 30 FILTER ON 60 OFF 120 ACTION EMAIL ACTIONCHANNEL DUTI RESETFUNCTION AUTOMATIC END gt LH LE ll AirTemp and DUT in the example must be already defined channels Abelko Innovation 97 WebMaster Pro WMPro Reference Manual 18 3 7 Database defines Databases are defined with a syntax according to the graph below bae o sel UPDATE SCRIPTED INTERVALL gt TIME number gt SECONDS SECONDS MINUTES MINUTES DAYS 1 f DAYS i There can be up to 6 databases numbered from 1 to 6 The start and end sectors refers to flash memory sectors numbered from 0 to 15 The end sector must be at least one higher than the start sector Ensure that databases do not overlap The update method SCRIPTED means that database updates will be controlled by script not by time This feature is not yet implemented INTERVALL means it will be updated with the stated interval The update will be performed when the system clock which counts seconds since 1 1 2000 is a multiple of the in
109. nto sub graphs The name submenu in the example above is the name of this sub graph A white box indicates a lexical element The keyword in the box has to be typed The script interpreter is case sensitive so if a keyword is in uppercase letters it must be typed in uppercase letters submenu A yellow box is a reference to another sub graph By following a syntax graph a syntactically correct statement and ultimately program can be formed Follow the direction of the arrows In the example after begin a choice must be made One of the three possible lines can be followed The bottom alternative is submenu i e a reference to itself The lines also indicate that a loop is possible A submenu statement may be followed by another submenu statement SUBMENU Example Headline BEGIN SUBMENU Submenu 1 BEGIN END SUBMENU Submenu 2 BEGIN END SUBMENU Submenu 2 BEGIN END END This submenu statement is syntactically correct according to the syntax graph Note tough that the syntax graphs only describes how to form syntactically correct statements They do not explain the semantics what the statement will do There may also be other restrictions on what is allowed It is syntactically correct to define a million levels of submenus The compiler will object though as there is a limit defined in the operator panel handling rout
110. o Reference Manual 17 Device Initialisation 17 1 Syntax A device initialisation initialises external devices This can be done in any script but only for type definitions already defined device DEVICE ov mee ener 4 AUTOMATIC Eb aes TYPEID gt nuwer ACTIONS telegram identifier p For GFBI devices ACTION defines telegram settings They can also have an INIT section where parameter values are set GFBI device initialisations will overwrite existing settings and nullify user changes on boot For AeACom devices a range of number be set to AeACom automatic i e reserving them for automatic assignment AeACom Automatic initialisations will not overwrite existing devices An automatic device can be made permanent and it will then not be reset to automatic by the script Abelko Innovation 87 WebMaster Pro WMPro Reference Manual 17 2 Telegram update interval codes The number stated after a telegram identifier is a code for the update time of that telegram What the codes mean is listed in the table below Code conversion to seconds Update times 1 9 Code 1 2 3 9 s 10 19 Code 9 10 10 20 30 100 s 20 28 Code 18 60 2 3 4 10 min 29 122 Code 26 300 15 20 25 480 min 17 3 Examples DEVICE DEV 2 Brunata Central
111. o be executed is defined in the system section The BOOT procedure will be executed once on system start up APPLICATION is a routine that is executed every second Shutdown and event are for future expansion These sections can contain any statements but for good readability it is recommended that they mainly use CALL to routines or procedures in the DEFINITIONS section NAME Example VERSION 0 1 INFO Example that does nothing SWREQ 1 0 HARDWARE MODE GOLIATH DEFINITIONS PROCEDURE Boot BEGIN PRINT GOOD MORNING TIME SHUTDOWN PROCEDURE Shutdown BEGIN PROCEDURE Event BEGIN Z Og APPLICATION ROUTINE Application BEGIN END END 18 3 Definitions This section deals with DEFINE statements in the definitions section There may also be routines and procedures defined in this section The routines have been explained earlier and the differences between routines and procedures will be explained later Abelko Innovation 90 WebMaster Pro W MPro Reference Manual The first part of a definition is always the same and follows the syntax define The things that might follow will be explained in later sections The identif
112. of time The mean value is updated every second each time representing more samples The most common use is with the Interval parameter set to zero The mean will then be reset when saved in database or on script command MathParl MathPar2 Interval time in second between resets Zero value means reset by database MathPar3 code if Chn MathPar3 i lt 0 Chn MathParl i 0 reset Chn MathParl i Chn MathParl i Chn Value i Chn MathPar3 i Chn MathPar3 i 1 if Chn MathPar3 i lt 0 Chn MathPar3 i 1 To avoid accidental divide by zero if Chn MathPar2 i gt 0 Chn Value i Chn MathParl i Chn MathPar3 i if Chn MathPar3 i gt Chn MathPar2 i Chn MathPar3 i 0 Chn MathParl i 0 else Chn Value i Chn MathParl i Chn MathPar3 i if Chn Flags i amp PB CHNFLAGS CLRDBS gt 0 CHANNEL ResetChannelMath Abelko Innovation 16 WebMaster Pro WMPro Reference Manual Variance The variance function calculates the variance of the input signal over a period of time The variance value is updated every second each time representing more samples The variance will be reset when saved in database or on script command Variance is a measure of how much the signal has varied The accuracy of the calculation is limited by the resolution of floating point values and operations MathParl mean MathPar2 S MathPar3 count
113. ot be saved to the WMPro unless you also press save in the script editor window Abelko Innovation 60 WebMaster Pro WMPro Reference Manual It is only routines that have an alias section that will show anything in the alias table 12 4 2 Saving and loading snippets The main reason for the snippets interface is to make it easy to reuse routines and to load device type definitions and other code to get external devices work The save to file button saves the selected snippet to a gpss file Gpss stands for goliath platform script snippet Insert from file load snippets from a file A gpss file can contain several snippets and they will be inserted after the selected snippet or first if no snippet is selected Remember to press apply and then save to activate the loaded script snippets Snippets for external devices will normally not need any editing but if a routine with an alias section is loaded it may be a good idea to check out that the aliases are connected to appropriate objects in the WMPro you are working with When writing a routine that will be reused make sure you use alias names and comments that helps the user to make correct connections 12 4 3 Moving and deleting snippets By using the up and down buttons in the snippets interface you can change the order of the snippets in the file For routines the order in the file determines the execution order which may be crucial For snippets that has references to ot
114. ower W L3 Power W 9600 CHECKSU TELEGRA QUEST BUS SWAPP ED DATA DATA DATA DATA DATA DATA ReadTypeCode ON UJ 0 0 0 0 0 Ei Ei Bi Ei DH x xX ANSWER TIMEOU DATA DATA DATA DATA DATA re Hj ll 03 4 K X r N T 1000 zi Z 4 ED R Type Code ypeCode DATA Abelko Innovation 70 WebMaster Pro WMPro Reference Manual The device address is declared as a parameter and all the values we will want to read are declared public There are also three private scaling variables that will come to use later The CHECKSUM declaration is important The CRC calculation method described in the Modbus standard has a special keyword in the script definition but it also has to be declared as SWAPPED This simple well defined telegram is a good way to test that the basic settings like address baudrate checksum and the physical wiring not the least really works 13 6 2 Reading data and scaling information Registers in Modbus are two byte words DATA 4 and DATA 5 in the question forms the number of registers to be read DATA 2 in the answer is the number of bytes in the answer This should be twice the number of requested regis
115. ppinit ini first Remember this effect also when an ini file from an older WMPro is used in a new one 19 9 Naming restrictions Since commas and semicolons are used by the parameter bank to separate values these are not allowed to be part of the value As many values are included in web pages there are more restrictions on which characters can be used in names and other strings without causing trouble Abelko Innovation 109 WebMaster Pro WMPro Reference Manual Most web pages and applets where names can be set checks for these bad characters and removes them before the string is sent to the parameter bank or gives an error message When bypassing these safety functions and writing directly to the parameter bank this has to be checked by the writer Failing to do so may cause the parameter bank to be corrupted or web pages to stop working Below is a list of the bad characters that should not be used in strings stored in the parameter bank Character ASCII code double quote 34 single quote 39 plus 43 comma 44 semi colon 59 rigth square bracket 91 back slash 92 1 left square bracket 93 19 10 System parameters The parameter numbers concerning the different functionalities are listed in the corresponding functionality chapter There are however more parameters of interest Parameters that deal with basic settings and system information Such parameters ar
116. re some unverified settings for a few named CRC algorithms 13 7 3 CRC16 CITT CHECKSUM CRC16 POLY 1021 NIT FFFF 13 7 4 CRC16 ARC CHECKSUM CRC16 POLY 8005 INIT 0000 REFIN REFOUT 13 7 5 XMODEM Kermit CHECKSUM CRC16 POLY 8408 INIT 0000 REFIN REFOUT 13 7 6 ZMODEM CHECKSUM CRC16 POLY 1021 INIT 0000 Abelko Innovation 75 WebMaster Pro WMPro Reference Manual 14 Group scripts 14 1 Introduction Group scripts are a way of dealing with an unknown number of external devices of a specified type From the group it is possible to get information about how many members it has and to get statistical values for variables of it members No explicit code is needed to calculate such as means or medians The ITERATOR is a special kind of routine that is executed on all devices in a group with its variables and parameters in scope as well as any aliased channels or other functionalities Where other languages uses for loops goliath platform script uses iterators The iterator is also the only way to access parameter values for individual devices form the script language 14 2 Syntax Below is the syntax graph for groups Groups can be defined both in user scripts and application scripts Abelko Innovation 76 WebMaster Pro WMPro Reference Manual
117. re updated AIN7 and T7 are measured AINS and T8 are measured There is a delay of approximately 120 ms between each point in this list Normally the system update will be completed before point 5 where the outputs are updated but there is no guarantee 2 9 2 System inputs The system inputs are a kind of virtual inputs that can connect channels with system status information The indexes have the following meanings Number Value 1 Network status Used by the WMPro appscript to blink the system led Modem supervision output If modem supervision is used this signals when the modem should be on and of Used by WMPro appscript to connect to DOUTS when modem supervision is active Prognosis active Used by ERIPX2 appscript Prognosis TOUT outdoor temperature Prognosis TO Used by ERIPX2 appscript Prognosis Te Used by ERIPX2 appscript SN t By Prognosis Te just Used by ERIPX2 appscript Abelko Innovation 11 WebMaster Pro Reference Manual 8 Prognosis difference Used by ERIPX2 appscript 9 Prognosis status Used by ERIPX2 appscript 11 Prognosis Forecast received 11 Prognosis Forecast error count 21 Proxy online 22 Proxy error count 1 23 Proxy error count 2 31 Portal updated 32 Portal error count 1 33 Portal error count 2 101 System statistic measure task execute ticks 102 Syste
118. s Page2 Page 3 Page 4 Page 5 Page 6 Page Page 8 Page 9 Page 10 Sensors amp Actuators Controllers Summary settings Name Page 1 Time control Add to view menu Update Over Row number Row type Information Communication 1 None System 2 None Advanced 3 None 4 None Channels 5 None Parameters 6 None Curves None 8 None Databases 9 Summaries 10 None Graphical programming 11 12 None Script 13 None Weekday catalog 14 None Database email 15 16 None Operator panel menus 17 None External units 18 None 18 20 None To make a new summary page go to Settings Advanced Summaries and select one page Pages that are already in use are marked with an Set the name of the page This is the name that will be shown as a new menu item on yellow background in the View menu Change Add to view menu to Yes and then click update The summary page is now available in the view menu although it is empty 8 3 Summary page rows For each summary page up to 20 rows may be defined Clicking on a row brings up a row editing window Edit Manual Example row 1 Select row function Header Line Image Link Channel value Parameter value Alarm status Database plot Edit curve plot Edit parameter value Edit channel scale offset Edit channel name unit Edit channel math function Edit channe
119. s reset Clears databases and event log Clear database 1 short time Clear database 2 hour Clear database 3 day Clear database 4 unused Clear database 5 unused Clear database 6 unused Clear event log 1 2 3 4 5 6 7 0 Clear all databases but not the event log Erases a selected file 1 Erase bootloader WARNING This is a self destruct command NEVER do this It cannot be undone Erase firmware Do not do this Erase application web pages Do not try this at home Erase application script appscript gps Erase appinit ini Erase uses web pages Erase user script userscript gps Erase user file 1 Oo ANIL t wl Erase user file 2 Erase user file 3 Erase user file 4 N Erase user file 5 Erase user file 6 Acknowledge reset event is to be replaced by a three letter signature written in the event log OfHt Reset event number 255 Reset all events and alarms Acknowledge reset Alarm 9 is to be replaced by a three letter signature written in the event log 113 WebMaster Pro WMPro Reference Manual Restarts the WMPro in a controlled manner BACKUP Perform the parameter storage routine normally executed every hours and before controlled restarts Tries to measure signal strength on
120. s and user files are so there is no reboot when the file is uploaded As the file is interpreted it can take some time to upload a large file 19 8 2 The Appinit ini file The appinit ini file is also a file that like the backup par stores an image of the parameter bank This file does not contain all information in the parameter bank It just contains a selection that represents the application part of the parameter settings not communication settings passwords and settings like that The appinit ini file is stored in flash It works as a local backup copy Another difference from the backup par file is that it uses a more compact format for encoding the parameter information This makes it less suitable for manual edit even if it is not impossible The file size of the Init ini file is limited to 64 kbyte by the flash sector size This means that there is no guarantee that all information will have room in the file This depends on how much of the WMPro that is used In normal cases everything will fit What will be stored in the appinit ini file depends on what is already stored If a file is present the selection of parameters it represents 15 used as base when a new file is generated If the file is empty a default selection is used Release 2 0 has extended the default selection to include new features such as external units and connections To be sure these are included when generating an ini file in an upgraded WMPro erase the old a
121. ssage indicates or somewhere earlier missing END or ENDIF keyword can result in error messages far from the actual error Keeping the code indented makes finding such errors easier Timer Timer 1 IF Timer gt Interval THEN Timer 0 ENDIF Power Power I SetValue RoomTemp IF Power gt PowerLimit OQutTemp THEN Power PowerLimit OutTemp ELSIF Power lt 0 THEN Power 0 ID Ts Messages Position Row 571 Col 2 UserScript gps line 585 col 4 Unknown identifier UserScript gps line 585 col 4 Error parsing statement block In the example above commenting out the ENDIF on row 571 cases an error message for row 585 where the routine ends This is also an example of multiple error messages on the same error Do not let the multiple messages confuse you the parser always stops on the first error it encounters The multiple messages is only there to give you extra hints on what the parser was doing When an error has been corrected press save again Unless you made a new mistake in your attempt to correct the first the parser will continue to the next error or actually save the file Abelko Innovation 58 WebMaster Pro WMPro Reference Manual 12 4 The Snippets Interface The snippets interface is just briefly discussed in the user manual It is a tool to work with scripts on a higher abstraction level In the snippets interface you do not work with code dire
122. t as the web pages in appweb bin are This file is distributed in update packages for WMPro The difference between user scripts and the appscript is that appscripts are allowed to initialize things at start up The channels used for inputs and outputs are defined here as are the databases Routines can be defined in the appscript and in WMPro the system led is controlled by a script in the appscript file The appscript is also allowed to run special script code at start up This code is allowed to do more things than the code that runs every second can do If the WMPro is to be adopted for a special purpose it may be suitable to use the appscript to do so When changing the appscript the WMPro will cease being a true WMPro It will be a new device based on the Goliath platform 70 2 Language basics The syntax of the script language is similar to that of Modula2 and other Pascal like languages It is NOT however a full featured programming language It is designed to be powerful and expressive enough to do everything you may need and want to do with the platform but in a way that prevents the programmer from making serious mistakes It is impossible to write a script that causes the system to crash Of course an erroneous script will not work but the communication will continue and it will be possible to replace the script file There are no types in the language All operations are performed on floats Constants in initiations and alike can
123. tabase and which values are to be shown The amount of data can also be defined Note that loading much data can take a long time Just loading the applet takes some time Iv G1 Temp C Iv 62 Temp C Restore 2 4 2004 01 14 2004 01 15 03 00 00 09 00 00 15 00 00 21 00 00 03 00 00 The curves are shown with a single Y axis 8 3 6 Curve The Curve option will display an editable curve on the summary page Point can be moved in the curve and saved but the advanced and text based curve editing options are not available Manual Example Y label 2 12 26 40 54 68 82 96 X label Update Abelko Innovation 35 WebMaster Pro Ww MPro Reference Manual 8 3 7 Edit parameter An edit parameter row makes it possible to change a parameter value from the summary page Edit channel value works the same way for channels Edit Manual Example row 1 Select row function Edit parameter value Help text Help text Parameter 74 Data type Float input field Boolean check box Float input field Cancel Which parameter to edit can be selected an optional help text be entered type of edit must also be specified The default method is float allowing the user to type any number Manual Example Help text Data 1 1 Update Help Text Boolean Edit Data 1 Update The other possibility is Boolea
124. tee tecta eee eee teens 98 15 3 8 Log entry definitions eie eee eerie ette ere tee ee 99 ISI MEMINI C 100 18 4 PROCEDURES AND STATEMENTS 0 0200000 0 0 010100000 00000000000000000000 101 1842 Procedures oun uenenum uten iine 101 10 423 ASSIgRTIORISA ai Un ERE Ge RARE e PRAE VR EE 101 16 4 3 PUTPAR statement nonnene oiana eair Enne enini nennen nennen nnn 101 1684441 Callstatements aeu Aedui onec vut tinet a ee eed 102 18 4 5 Update ue tuo ao I aen a een cer estie 102 19 THE PARAMETER BANK 5 inei eon toen o ron onera ba rae Ea noh na oen tantu Pub een insano een 103 19 1 INTRODUCTION 5S RP 103 19 2 PARAMETER NUMBERS 4 0 00 01001010000000000000000000000000 103 19 3 104 19 4 104 19 5 GEIPARTSSIS s os 105 Abelko Innovation 5 WebMaster Pro WMPro Reference Manual 19 6 19 6 1 19 6 2 19 7 19 7 1 19 7 2 19 7 3 19 7 4 19 7 5 19 7 6 19 8 19 8 1 19 8 2 19 9 19 10 19 11 GETPARX SSL 52552 edic tetra ted p eR EHE ete ep e RI eir 105 Multiple parameter retrieval
125. ters As measured values are read from word sized registers they often need to be scaled in order to get a decimal point in the reading Often the scaling is fixed for specified registers and stated in the documentation In the WM22 however the scaling for Volt Ampere and Watt readings are not fixed The scaling to be used is coded into a byte and stored in register addresses 0244h 0245h and 0246h We need a telegram to read these registers and store the scaling factors in the private variables VScale AScale and PScale As they are consecutive we can read them all at once specifying that we want to read three registers starting at 0244h TELEGRAM ReadFormatiInfo NAMED R Format Info IS QUESTION DATA 0 BYTE Id DATA 1 HEX 04 DATA 2 HEX 02 DATA 3 HEX 44 DATA 4 HEX 00 DATA 5 HEX 03 ANSWER SIZE 1 DATA O BYTE Id DATA 1 HEX 04 DATA 2 06 DATA 3 gt IF DATA 3 THEN VScale 0 001 ELSIF DATA 4 THEN THEN VScale 0 01 ELSIF DATA 5 THEN THEN VScale 0 1 ELSIF DATA 6 THEN THEN VScale 1 ELSIF DATA 7 THEN THEN VScale 10 ELSIF DATA 8 THEN THEN VScale 100 ELSIF DATA 9 THEN THEN VScale 1000 ELSIF DATA 0 THEN THE
126. terval This means that with a one hour update interval the database will update every full hour The TIME update method provides a way to shift the update time UPDATE TIME 1 HOUR 4 5 MINUTES This example will make the database update five minutes past every full hour Decimal numbers are allowed in the update initiation With CHANNELS it is possible to define which channels to store in the database Remember that changing a database CHANNELS definition will make the already stored data faulty Below are the database definitions for WMPro They contain no definition of the content of the databases DEFINE DB1 AS DATABASE NAME DB Short Time TIMESTAMPS POSTPERIODAL Abelko Innovation 98 WebMaster Pro WMPro Reference Manual STARTSECTOR 0 ENDSECTOR 7 UPDATE INTERVALL 1 SECONDS END DEFINE DB2 AS DATABASE 2 NAME DB Hour TIMESTAMPS POSTPERIODAL STARTSECTOR 8 ENDSECTOR 11 UPDATE TIME 1 HOURS 3599 SECONDS END DEFINE DB3 AS DATABASE 3 NAME DB Day TIMESTAMPS POSTPERIODAL STARTSECTOR 12 ENDSECTOR 155 UPDATE TIME 1 DAYS 86399 SECO
127. the number of time segments 15 2 AeACom Configuration The AeACom master in the WMPro must be configured so that it knows what to send in the sync frame Below is an example of such a configuration AEACOM2 CONFIGURATION BAUDRATE 19200 SEGMENT LENGTH 200 SEGMENTS 64 CYCLE TIME 15 R T 42 SEGMENTS 0000 0000 0000 0000 0000 0000 0000 0000 RANSMIT SEGMENTS 0000 0000 0000 0000 0000 0000 0000 0000 ACCEPT UNKNOWNS Segment length is in ms but cycle time is in seconds The number of segments segment time and cycle time must be carefully selected to work The length of a segment must be enough to fit both the telegram from the device and the answer from the master with enough margins for answer calculations and synchronisation mismatch The segments themselves must fit in the bus cycle The maximum number of segments is 128 Reserved and transmit segments are segments that never will be reported as free They are marked out by a hex number bitmask In Release 2 0 the master has no use for reserved segments but use will be implemented in the future The transmit segments are reserved for command transmits from the master The syntax graph for a AeACom configuration is shown below Abelko Innovation 83 WebMaster Pro 8WMPro Reference Manual aeaconfig AEACOM2 CONFIGURATION BAUD RATE
128. the scripts and put all the power of WMPro at your feet The user manual used a garden gnome as a simile to explain the script interpreter in relation to channels alarms and databases A very small garden gnome somewhat stupid but very dedicated to its task Every second it wakes up and dutifully performs the tasks listed in the script files having access to almost all subsystems in the WMPro There are two script files the Appscript gps and the Userscript gps These store the scripts in their text format The user script is intended for the user to edit The user script file actually contains three different user scripts with their own separate program memory areas The first is reserved for the controller applet The applet stores not only the script that implements the controller in this area but also metadata on the configuration The second area is used for graphical programs Both the generated scripts and the graphical layout are stored here User script three however this is where you are free to create your own scripts It is accessed through the script editor applet This simple built in editor uses colour coding to make scripts easier to read and write and the applet hides all the other scripts stored in the same file When the user script is saved it is first checked so that the syntax is correct If it contains errors this is reported and the WMPro refuses to save the file The appscript file is part of the application jus
129. tion Link Help text Help text Link name www abelko sel Manual Example Help text www abelko se Clicking on the link will open it in a new window or a new tab depending on the browser 8 3 4 Channel value Parameter value and Alarm status The options Channel Value Parameter Value and Alarm Status is quite similar in that they show the present value of a selected object Row number Row type Information 1 Channel value Temp 1 2 Parameter value Data 1 3 Alarm status Alarm 1 4 None For each of these row the channel parameter or alarm that is to be shown has to be selected and an optional help text can be entered Manual Example Heip text Temp 1 155 1 1C Help Text Data 1 2 00 Help Text Alarm 1 Not active On the summary page channels parameters and alarms are shown in different colours to make it easier to understand what is shown The colour scheme is the same as is used in for example graphical programming and the operator panel menu tool Channel names are green parameter names blue and alarms red 8 3 5 Database The database option will add a database plot to the summary page Abelko Innovation 34 WebMaster Pro WMPro Reference Manual Edit Manual Example row 1 Select row function Database plot Database DB Short Time vr Channel 1 cen 2 4 Channel 2 2 Temm YS Channel 3 1 Amount of data 96 10 Y The arguments for the database row are which da
130. tion simply write a new name an equals sign and then object it will represent The object must be an existing object To the right of the equal sign you can use an absolute identifier as specified by the syntax graph below Komal The number between the square brackets is the index of the referenced object For channels this is a number between 200 parameters is 1 to 100 alarms 1 to 50 calendar 1 to 5 and curves ranges from 1 to 10 If it sounds awkward to keep track of channel indexes be calm The script editor has a tool to help generating aliases There is also a tool for exchanging aliases when reusing a routine in a new context This will be explained in detail in a later chapter Below is an example of a routine declaration including an alias section Abelko Innovation 45 WebMaster Pro WMPro Reference Manual ROUTINE Example ALIAS Temperature CHANNEL 1 RefTemp PARAMETER 1 PFactor PARAMETER 2 TempToValve CURVE 3 Valve CHANNEL 25 VAR PT BEGIN Err RefTemp Temperature Valve TempToValve Temperature Err PFactor END Note that an alias is not a C style define You can only create aliases for objects like channels and parameters The number between the square brackets must formed by digits Expressions are not allowed 11 1 2 Variables In a routine it is possible
131. tion script can be customized for special applications but it will then no longer be a true WMPro It will be a new application built on the Goliath platform 18 2 Application script structure Below is the main syntax for application scripts script SCRIPT Kar i VERSION E a HARDWARE MODE GOLIATH ial DEFINITIONS i SYSTEM APPLICATION Abelko Innovation 89 WebMaster Pro WMPro Reference Manual The first part of an application script is informative A name and an information string are defined and can be presented on web pages to the user The version number is also just for information SWREQ is information about which firmware revision is required in order for the script to work The hardware mode selection defines what hardware is expected and which measure routine to be used GOLIATH is the standard hardware mode and currently the only mode supported In the definitions section routines and procedures are declared and channels parameters and other system elements defined and initialised Routines and procedures can be defined here too They will not be automatically executed as they are in user scripts Another difference from user scripts is that all defined object names like for initialised channels are in scope in the routines and procedures This reduces the need for alias sections What routines and procedures are t
132. vation 24 WebMaster Pro WMPro Reference Manual ABS stands for absolute value 4 BETWEEN Channel gt TrigLim1 AND Channel TrigLim2 5 OUTSIDE Channel lt TrigLim1 OR Channel gt TrigLim2 6 EQUALS Channel TrigLim1 TrigFilterOn modifies the condition in that the condition must be true for the number of seconds TrigFilterOn stores before the alarm is triggered TrigFilterOff is the same modifier for alarm deactivation TrigFilterCounter is used internally to count for how long time a condition has been met TrigHysteresis is another modifier that changes the TrigLimits for the deactivation of an alarm The hysteresis value is either added or subtracted from the limit depending on which limit and the condition type It is used to prevent an alarm from being activated and deactivated repeatedly when a channel value is oscillating close to a trig limit The trig limit is not affected by Hysteresis when the condition is EQUAL 4 4 Alarm Action Channel When a channel is selected as action channel for one or many alarms the channel value will be assigned the number of active alarms with the channel set as action channel The action channel update is performed in two steps In the first step all alarms are scanned and all action channels are set to zero In the second stage after all alarms has been updated the alarm list is scanned again For all active alarms with an assigned action channel that
133. x graph are related to communication and external devices 11 1 Routine declarations A routine is a subroutine that can be executed every second In a user script all declared routines will be executed once every second in the order they are declared in the file A routine should take care of one specific task or subsystem in the application This makes the script code easier to understand and easier to reuse If the application cannot be broken up in smaller tasks then one big routine might be the best solution Routines cannot communicate with each other than trough common channels If two routines have very many common channels the code may be more readable and less error prone if they merged in to one large routine Below is the syntax graph for a routine Abelko Innovation 44 WebMaster Pro WMPro Reference Manual routine eo statements lt END a The routine_id routine identifier is simply a name for the routine As al identifiers it must be one word with no separators in it It may include letters digits and the _ character ASCII codes Category 65 90 95 97 122 128 255 LETTER 48 57 DIGIT 11 1 1 The Alias section In the alias section it is possible to create aliases for channels parameters curves alarms and time controls calendars In user scripts this is necessary to connect the routine with the rest of the WMPro To declare an alias in the alias sec
134. y look like the shortened example below Test 155 1 C Forward Temp 153 1 C Temp 3 153 8 C Temp 4 155 7 C Temp 5 152 7 C Temp 6 154 3 C Temp 7 155 5 C Temp 8 155 7 C Analog 1 U 0 1 V The maximum number of parameter arguments to getparx is 10 19 6 2 Flag selection filter So far we have seen the possibilities of retrieving one specific value or all values in a parameter With getparx there is also a possibility to get only values instances where the corresponding flag parameter meets a specified condition Flags will be explained more thoroughly later There is a flag set for all used instances of objects This flag has the bit mask value of 64 This example will get the names of all used channels http 10 0 48 94 getparx ssi pararg p501x0y0z0b64 64 whilst http 10 0 48 94 getparx ssi pararg p501x0y0z0b64 0 will get all the unused The value after the b in the parameter specification is anded with the flag word that belongs to the object the parameter refers to and the result is compared with the value after the comma If equal the value is included in the result When using this feature one problem may be that you do not know the indexes x value of the values returned For many functionalities there is therefore a XNR parameter For alarms this parameter has number 1118 The example below will return index and name of all used alarms http

Download Pdf Manuals

image

Related Search

Related Contents

Notice produit Zodiac Pool Care Europe  Istruzioni d`uso Asciugatrice a pompa di calore  12 MP WILDKAMERA GAME CAMERA (DE  関連PDF1 ワイヤレスマイクロホン 取扱説明書    Betriebsanleitung  Soporte BKL-LA5 de Christie Vive Audio  TOP-BRILL - Quimicas Morales  Philips PD7022/12 User's Manual  Manivelle de sécurité double sens DS 250 – mode d`emploi  