Back-UPS RS APC BACK-UPS RS 800VA 230V
Contents
1. Back UPS RS APC BACK UPS RS 800VA 230V Standard Lead Time Usually in Stock APC Back UPS RS 540 Watts 800 VA Input 230V Output 230V Interface Port USB Includes CD with software Cord management straps Documentation CD Qty 2 Detachable IEC C13 to IEC C14 power cords Telephone Cable USB cable User Manual Wall mounting template Back UPS RS Features amp Benefits BR800I Features Serial Connectivity Use any Home Automation network to monitor and control the S20 through its RS 232 serial port For information on how to communicate with the S20 see APC s Application Note 102 Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks USB Connectivity Provides management of the UPS via a USB port not available on all models Serial Connectivity Provides management of the UPS via a serial port Protection Battery protected and surge only outlets Reserves power capacity and run time for connected equipment that require battery back up while providing surge only protection for less critical equipment Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery Data line surge protection Provides protection of connected equipment from power surges on the data lines Safety agency approved Ensures the product has been tested and approved
2. Storage Elevation 0 15000 meters Audible noise at 1 meter from surface of unit 45 00 dBA Online Thermal Dissipation 170 00 BTU hr Conformance Regulatory Approvals A tick C tick CE GOST GS Mark VDE Standard Warranty 2 years repair or replace ROHS WEEE Compliance RoHS SPECIFICATIONS Item Specification On line Input Voltage Range default settings 176 294 Vac Automatic Voltage Regulation AVR 12 On line Frequency Range 47 63 Hz autosensing On battery Waveshape Stepped Sine Wave Maximum Load 800 VA 540 W Typical Recharge Time 8 Hours Operating Temperature 0o to 40oC 32o to 104oF Storage Temperature 5o to 45oC 23o to 113oF Operating Storage Relative Humidity 0 to 95 non condensing Size H x W x D 23 x 10 x 32 cm 9 x 4 x 12 75 inch Weight 9 3 kg 20 5 lbs Shipping Weight 9 9 kg 22 lbs EMI Classification EN 50091 1 EN 60950 EN 50091 2 EN 61000 3 2 EN 6100 3 3 EN 55022 Class B On Battery Run Time TROUBLESHOOTING Problem Possible Cause Corrective Action Back UPS will not switch on Back UPS not connected to AC power source Ensure the Back UPS is securely connected to an AC outlet Back UPS circuit breaker tripped Disconnect non essential equipment from the Back UPS Reset push in the rear panel circuit breaker Switch on the Back UPS and plug in devices one at a time If the circuit breaker trips again disconnect the device th
3. to work safely with the connected service provider equipment and within the specified environment UL FCC CE C Tick approvals Power conditioning Protects connected loads from surges spikes lightning and other power disturbances Convenience Audible Alarms Provides notification of changing utility power and UPS conditions Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power Automatic self test Periodic battery self test ensures early detection of a battery that needs to be replaced Battery replacement without tools Allows quick easy battery replacement LED status indicators Quickly understand unit and power status with visual indicators Cold start capable Provides temporary battery power when the utility power is out Hot swappable batteries Ensures clean uninterrupted power to protected equipment while batteries are being replaced Resettable circuit breakers Enables a quick recovery from overload events Transformer block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles User replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR Manageability Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or ge
4. at caused the breaker to trip Utility input voltage quality is out of range Consider adjusting the transfer voltage and sensitivity See Transfer Voltage and Sensitivity Adjustment Internal battery cartridge is not connected Connect battery cartridge see Connect Battery Cartridge Back UPS does not power essential equipment during an outage Equipment plugged into a Surge Only outlet Unplug device from Surge Only outlet and move to a Battery Backup outlet Back UPS operates on battery although utility power exists Back UPS circuit breaker tripped Disconnect non essential equipment from the Back UPS Reset push in the rear panel circuit breaker Switch the Back UPS on and plug equipment in one at a time If the circuit breaker trips again disconnect the device that caused the breaker to trip Utility input voltage quality is out of range Consider adjusting the transfer voltage and sensitivity See Transfer Voltage and Sensitivity Adjustment Back UPS does not provide expected backup time Back UPS is heavily loaded Unplug non essential equipment printers scanners etc from the Battery Backup outlets and plug into Surge Only outlets Back UPS battery cartridge is discharged due to recent power outage and has not had time to recharge Charge the battery cartridge for 8 hours Back UPS runtime is reduced until the battery cartridge is fully charged Battery has reached the end of its life Replace b
5. attery cartridge see Order Replacement Battery Cartridge Red Replace Battery indicator is flashing Green On Line indicator is on Internal battery cartridge is not connected Connect battery cartridge see Connect Battery Cartridge Red Replace Battery indicator is on Battery has reached the end of its life Replace the battery cartridge see Order Replacement Battery Cartridge Red Overload indicator is on or flashing Connected equipment is drawing more power than the Back UPS can provide Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets Green On Line indicator is on and all other front panel indicators are flashing Internal UPS fault Contact APC Technical Support see Contact Information SERVICE If the Back UPS arrived damaged notify the carrier If the Back UPS requires service do not return it to the dealer The following steps should be taken 1 Consult the Troubleshooting section to eliminate common problems 2 If the problem persists go to http www apc com support 3 If the problem still persists contact APC Technical Support 4 Have the Back UPS model number serial number and date of purchase available Be prepared to troubleshoot the problem with an APC Technical Support representative If this is not successful APC will issue a Return Merchandise Authorization RMA number and a shipping address LIMITED WARRANTY The standard warranty is t
6. g Mode 3 The Back UPS will then indicate its current Sensitivity Setting as shown in the following table 4 To select the Low Sensitivity setting press the pushbutton until the yellow indicator is flashing 5 To select the Medium Sensitivity setting press the pushbutton until the yellow and red indicators second and third from the top are flashing 6 To select the High Sensitivity setting press the pushbutton until yellow and both red indicators bottom three are flashing 7 To exit without changing the Sensitivity Setting press the pushbutton until the green indicator is flashing 8 Once in Programming Mode if the pushbutton is not pressed within 5 seconds the Back UPS will exit Programming Mode all indicators will extinguish Indicators Flashing Sensitivity Setting Input Voltage Range for utility operation Use When 1 yellow Low 156 300 Vac Input voltage is extremely low or high Not recommended for computer loads 2 yellow and red Medium factory default 176 294 Vac Back UPS frequently goes On Battery 3 yellow red and red High 176 288 Vac Connected equipment is sensitive to voltage fluctuations recommended
7. larged Chart Curve fit to measured efficiency data All measurements taken in normal operating mode at typical environmental conditions with nominal electrical input and resistive load output Communications amp Management Interface Port s USB Control panel LED status display with On Line On Battery Replace Battery and Overload indicators Audible Alarm Alarm when on battery distinctive low battery alarm configurable delays Surge Protection and Filtering Surge energy rating 320 Joules Filtering Full time multi pole noise filtering 5 IEEE surge let through zero clamping response time meets UL 1449 Data Line Protection RJ 11 Modem Fax DSL protection two wire single line RJ45 10 100 Base T Ethernet protection Physical Maximum Height 229 00 mm Maximum Width 102 00 mm Maximum Depth 324 00 mm Net Weight 9 32 KG Shipping Weight 10 23 KG Shipping Height 305 00 mm Shipping Width 229 00 mm Shipping Depth 432 00 mm Master Carton Units 2 00 The time to recharge to 90 of full battery capacity following a discharge to shutdown using a load rated for 1 2 the full load rating of the UPS Master Carton Weight 48 00 lbs Color Beige SCC Codes 0073130419246 6 Units per Pallet 40 00 Environmental Operating Environment 0 40 C Operating Relative Humidity 0 Operating Elevation 0 3000 meters Storage Temperature 5 45 C Storage Relative Humidity 0
8. nerator applications Adjustable voltage transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation Serial Connectivity Provides management of the UPS via a serial port USB Connectivity Provides management of the UPS via a USB port not available on all models Multiple mounting methods Allows for standardization on one product for use in different environments Intelligent Battery Management Micro processor controlled battery charging and diagnostic testing ensures maximum battery life Output Output Power Capacity 540 Watts 800 VA Max Configurable Power 540 Watts 800 VA Nominal Output Voltage 230V Output Connections 2 IEC 320 C13 Surge Protection 4 IEC 320 C13 Battery Backup Input Nominal Input Voltage 230V Input Frequency 47 63 Hz Input Connections IEC 320 C14 Cord Length 1 83 meters Input voltage range for main operations 175 295V Input voltage adjustable range for mains operation 160 300V Batteries amp Runtime Battery Type Maintenance free sealed Lead Acid battery with suspended electrolyte leakproof Included Battery Modules 1 Typical recharge time 8 hour s Replacement Battery RBC32 RBC Quantity 1 Typical Backup Time at Half Load 17 8 minutes 270 Watts Typical Backup Time at Full Load 5 3 minutes 540 Watts Runtime Chart Back UPS RS Energy Use Efficiency View En
9. wo 2 years from the date of purchase APC s standard procedure is to replace the original unit with a factory reconditioned unit Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative APC will ship the replacement unit once the defective unit has been received by the repair department or cross ship upon the receipt of a valid credit card number The customer pays for shipping the unit to APC APC pays ground freight transportation costs to ship the replacement unit to the customer TRANSFER VOLTAGE AND SENSITIVITY ORDER REPLACEMENT BATTERY CARTRIDGE The battery cartridge typically lasts 3 6 years shorter if subjected to frequent outages or elevated temperatures Order part number RBC32 Please recycle spent battery cartridges ADJUSTMENT REPLACE BATTERY CARTRIDGE 1 2 3 4 In situations where the Back UPS or connected equipment appears too sensitive to input voltage it may be necessary to adjust the transfer voltage This is a simple task requiring use of the front panel pushbutton To adjust the transfer voltage proceed as follows 1 Plug the Back UPS into the utility power source The Back UPS will be in a Standby Mode no indicators lit 2 Press the front panel pushbutton fully inward for 10 seconds All indicators on the Back UPS will flash to acknowledge going into Programmin