(CR800 & CR1000) LITE

image

Contents

1. Figure 18 Collecting Data Clocks Adjusted Server Date Time 22 12 2011 17 00 11 Station Date Time 22712 2011 17 00 11 Check Sel C Pause Clock Update Program 2177 27 a 0 00 CRS Once the data is collected it will produce data files that are in comma separated format These will be named in the style SalesOrderNumber_WhatData_LoggerlD dat There may be several of these for different units or for different instrument types The File Name column will indicate the location on the computer that the file has been saved to See Figure 19 Bell Lane Uckfield East Sussex TN22 1QL United Kingdom t 44 0 1825 765044 e f 44 0 1825 761740 info itmsoil com w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoil INSTRUMENTS Connect Screen CR amp 00Series CR amp 00Senes cs File Edit View Datalogger Help ay amp amp Disconnect Collect Now Custom B IE a Station Status File Control Hum Display Graphs Ports amp Flags Stations Table Monitor Real Time Monitoring Clocks CRS00_AS232_ 38400 22 12 2011 17 01 00 CRS00_AS232_ Other Station DateTime CR1000_AS232_115200 CRIOO0_AS232_ 38400 FR uae 221272011 17 07 00 CR1000_RS232 Other RecNum BF La cai Soil SIM TimeSt 2271272011 17 00 48 Progy er 1 2177 233 CATO LoggerlD afd Pause Clock Update Data Collection
2. t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS g Connect Screen CR amp 00S5eries CRE00Sernes File Edit View Datalogger Help ae A B 2 E Collect How Custom Station Statue File Control Hum Display Graphs Ports amp Flags Stations Table Monitor Passive Monitoring Clocks oe Show Units Adjusted Server Date Time Field lv Mine Station Date T ime Pause Clock Update Program elf i 2 a000 CRS Notes List Alphabetically Ip 0 00 00 00 tiara Figure 15 Highlight the logger and select Connect Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 3 1 Viewing current data Once connected it is possible to view the last readings taken and change some of the logger parameters This is done by accessing the Public table from the drop down menu on the connect screen see Figure 16 Cannmect Soren CRADOSenes CRADDSenes File Edt Vew ODatalogger Help 4 8 8 a Disconnect Colect Ho
3. Results Sa Summary 273 0 00 CR8 Table File Name File Mode File Format 016825_All 273 C A CampbellsciLoggerNetiCR800Series SO16825_All 273 dat Append to File ASCI TOAS Total number of values collected Linear Murt SGH 1 3996 Lin arMuxl_ SG 5 99598 Lin arMux1_ SG 6 9998 Lin arMuxl_ SG 99598 Lin arMux1_SG 8 9998 Temperature _Musi_SG 1 1 36 6041 Temperature_Muxl_SG 2 24 01923 Temperature_Musx1_ SG 3 151 2146 Temperature _Musi_SG 4 135 4958 Temperature_Musxl_ SG 5 141 0742 Temperature_Muxl_SG B 143 1111 Temperature _Musi_SG F 137 6276 List Alphabetically Temperature_Mux1_SGIB 137 0982 By 0 01 20 09 meral omms Figure 19 DataTables Collect The data files can easily be uploaded straight in to ARGUS D4 2 0 which is custom configured to deal with data from data loggers There are also advanced options in the setup screen which allows for this to be scheduled and run automatically Alternatively the data can be viewed and manipulated in Excel or a similar data processing program The data is comma separated For further advanced guides or technical support please go to www itmsoilsupport com to view various knowledgebase articles or submit a support ticket Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Register
4. Server Dae Tima zaara 1d203 Chabon Dishes iene 2AA Vd 03 Pma Clock Upelahe Program Sirra 000 ORG Hom 44 0 1825 765044 44 0 1825 761740 Sef e info itmsoil com w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS Connect Screen CR amp 00Series CRE00Senes File Edit View Datalogger Help vi Disconnect Custom Collect Now Stations CR800S erie CRS00_AS232_38400 CRSU0_AS232_ Other CR1000_A5232_115200 CR1000_A5232_38400 CR1000_A5232_0ther Soil SIM 2177 234 21 F 233 CA TL Collecting Data E List Alphabetically ia 0 01 19 13 l re z j a B ieee Station Status File Control um Display Graphs Ports amp Flags Table Monitor Real Time Monitoring Field value RecNurn G6 E TimeStamp 22 12 2011 17 00 00 Progy er 1 LoggelD era Measlnty Collecting data from CR amp 00Series Linear Mux SG 3 LinearMuxl_SG 4 Linear Mux SG 5 LinearMux_ SG B Linear Mux SG Linear Mux SG 8 Temperature_MMusl_SG 1 Temperature_Mux1_SG 2 Temperature_Mux1_ SG 3 Temperature_Mux1_SG 4 Temperature_Mus1_SG 5 Temperature _Mus1_SG 6 Temperature_Mus1_ SG Temperature_Mux1_SG 8 3995 60 3995 3995 3955 3995 3998 138 8171 24 03229 135 0946 136 604 145 1601 135 7047 138 5011 HAN Interval 00 m 01
5. ata Tools Utilities Favorites CAMPBELL SCIENTIFIC Figure 6 Highlight Main then select Setup Note The following screen is the EZ View which guides through the setup If your view is not the same please select the icon in the top right of the screen cy EZ EZ View Setup Screen EZ Simplified View Lo e es Network es lete vA ww Std View Datalogger Information Datalogger Name CR1000_11520_CS10 Datalogger Type CR1000 Unsupported Connection Type This datalogger has a configuration that is not eae in the EZView The datalogger has siblings on the same PakBus Switch to the Standard View to edit this datalogger m Figure 7 Select Add Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS E7Setup Wizard Progress introduction Introduction Communication Setup et ie The EZSetup wizard will guide you through the process of setting up Datalogger Settings To a F your datalogger Follow the aT Instructions given and use the Previous and Next buttons below to Setup Summary navigate through the wizard Communication Test Click Next to continue Datalogger Clock Send Program Data Files Schedul
6. e logger Please refer to the wiring diagram as the ports on the logger will have their baud rates labelled on them E Setup Wizard CR amp 00Series CR800Series Progress Communication Setup Summary Introduction RS The following i a summary of the datalogger setup Berman iestion 2 alue Datalogger Information Datalogger Name CR S005 eres Datalogger Settings Datalogger Type CAR800S eres Setup Summary Direct Connect Connection COM Pork Communications Port COM Communication Test Datalogger Settings Baud Rate 175200 Datalogger Clock PakBus Address 1 Security Code 0 Send Program Extra Response Time Os Maz Time Online 0h Om Os Data Files Scheduled Collection Wizard Complete 4 Previous chee CFs Cancel Summary Help Figure 13 Select Finish Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 3 Accessing Data from a Data logger Once the above setup is completed under the main menu select Connect See Figure 14 Program m L 7 Tools sce A Favori es ae Figure 14 Opening the Connect Screen On the Connect Screen highlight the logger that was setup and then select Connect See Figure 15 Bell Lane Uckfield East Sussex
7. ed Collection Wizard Complete Figure 8 Select Next EZ5etup Wizard CR amp 00Seres CR3005eries Progress Datalogger Type and Name Introduction i Select the datalogger type and enter a name Communication Setup ra WP for your datalogger Datalogger Settings Datalogger Hame CAS00S eres Setup Summary Communication Test Datalogger Clock Click Nest to continue Send Prograrn Data Files Scheduled Collection Wizard Complete Figure 9 Select the logger type and assign a name This will either be a CR800 or CR1000 If unsure please either physically inspect the data logging system or view the wiring diagram to identify your logger type Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoil INSTRUMENTS E Setup Wizard CR amp 00Series CR amp 00Series Progress Connection Type Introduction Select the mode of communication that will be used for this datalogger Communication Setup 4 Di A direct connection consists of a datalogger Datalogger Settings with an AS 232 port connected to the serial port on the computer If the datalogger has only a CS 170 port then the connection is through an appropriate interface device e g SC929 9 pin cable or SCI24 S C326 Optically I
8. ed Office Bell Lane Uckfield East Sussex TN22 1QL
9. itmsoll INSTRUMENTS Document Title CAMPBELL BASED MULTI CHANNEL DATA LOGGER LITE USER MANUAL Man158a 1 A5 03 10 2012 Final Ben Stuart James Scott Burgess Kwist Manual Revision Date Status Originator Checked Authorised No for Issue Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoil INSTRUMENTS INDEX 1 Introduction 2 Direct Connection Setup 2 1 Hardware 2 1 1 Hardware for connecting using the RS232 Port 2 1 2 Hardware for connecting using the CS I O Port 2 2 Loggernet setup 3 Accessing Data from a Data logger 3 1 Viewing current data 3 2 Downloading data Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 1 Introduction This guide details the operations needed to Connect and Download Data from itmsoil Instruments Data Acquisition System DAS This is done by using the datalogger support software Loggernet software D2 1 1 Data is stored within the dataloggers memory when the memory limit is reached the oldest readings will start to be overwritte
10. n Routinely connecting and downloading readings from the datalogger to a PC will ensure the readings are backed up 2 Direct Connection 2 1 Hardware On the CR800 and CR1000 there are two 9 pin ports that can be used for connecting into the data logger These are the RS232 and CS I O port See Figure 1 Figure 1 CS I O and RS 232 9 pin ports shown on a CR800 Note Some loggers will already have other peripherals attached to these ports eg A Modem or AVW200 If this is true ideally it is advised not to use these ports If no other option but to remove one of the connections make sure they are re connected in the same way Removing some peripherals may mean that it is not possible for live readings to be taken Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 2 1 1 Hardware for connecting using the RS232 Port For connection using the RS232 port a male to female 9 pin RS232 serial cable is required See Figure 2 Figure 2 RS232 Cable Note Most PCs and Laptops will have a 9 pin VGA output this is not suitable for connecting the Logger via a RS232 Serial cable to This then needs to be connected to a PC or Laptop Not all modern laptops and PCs will have the necessary serial output T
11. o solve this a USB to RS232 cable D1 3 11 can be used See Figure 3 This will require drivers to be installed for the cable to be recognised a CD containing the drivers will accompany the cable Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll Figure 3 USB to RS232 Cable 2 1 2 Hardware for connecting using the CS I O Port For connecting using the CS I O port of the data logger a special cable or adapter is required See Figure 4 amp 5 Figure 4 RS232 to CS I O Cable Bell Lane Uckfield East Sussex 44 0 1825 765044 info itmsoil com TN22 1QL United Kingdom 44 0 1825 761740 www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 5 CAMPBELL SCIENTIFIC CE Sc 32B Computer Made in USA AL WRAL AA A 2726 Figure 5 RS232 to CS I O Adapter Bell Lane Uckfield East Sussex t 44 0 1825 765044 e TN22 1QL United Kingdom f 44 0 1825 761740 info itmsoil com w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 2 2 Loggernet setup Program D
12. om f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoil INSTRUMENTS E Setup Wizard CR amp 00Series CR amp 00Series Progress Datalogger Settings Introduction Baud Aate Enter the baud rate that will be used in communicating with the datalogger Hote The mas baud rate for Communication Setup mimin C324 interfaces is 19 200 bps The mas for SC929 is Datalogger Settings Apngue PakBus address is used to identity the datalogger in the Fak Bus network Enter the PakBus Setup Summary Address that was set on the datalogger Walid range is 1 4054 Suggested range is 1 3995 Communication Test i If a security code ts set on the datalogger it must be entered here for communication and data collection to Datalogger Clock occur O means security will not be used Send Program Extra Response Time IF the datalogger requires extra time to respond enter 00 seconds the extra response time Data Files Scheduled Collection Max Time On Line Because some links are costly it may be desired to have the connection closed automatically Enter the 00 h OO m O s masimum time for a connection to stay online O means stay online until the user disconnects 4 Previous Next f Cancel Settings Help Wizard Complete Figure 12 Select the applicable baud rate This may differ depending on the setup of th
13. ring diagram by the mux multiplexer number and sensor number They will also indicate sensor type and unit Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoll INSTRUMENTS 3 2 Downloading current data To download data you will need to connect to the data logger as detailed above then select the Collect Now button at the top of the connect screen see Figure 17 Ed Connect Screerc CREDOSenes CREODSenes File Edt Yia Litt Aipha ay TP 0 00 01 05 PTeme Stra Mui Saji me a T EE E usien Mi Seta diiran Wsi SGH uStrn_Muxl_SGy5 airan Hul Sati wairan Mul Sar asian Mil Sath Las Wii Saji Linea Mu SG 2 Linear Mul SGN Liew Mul _SG 4 Linesa Hul _SG 5 Linea Mun SGE Lines Mun _ SG Linas Mun S0 Terceatue Minl SGi Terpasuwa bwl SGI Temgawua Wii SGA Torpes Muni SG Tempamue_ Mul _ SGH Temperate _ Mul SE Tempetatue_ Mul Sj Tempetatue_Miol_ SE Figure 17 Collect Now Bell Lane Uckfield East Sussex TN22 1QL United Kingdom Vou a aaa 141 51 1 273 EI imie 351 12 23508 2a MG 311 216 i442 389 616 AE BIE 4468 016 S07 216 Se OL 2585 615 pss TERE 134 508 2a 57614 146 9753 146 5753 1402406 141 5308 141 0742 THEN iL Pp Adpvied
14. solated AS 232 Interface IF Fort RFIS R FARK Setup Summary RFA Non FPakBus Communication Test Datalogger Clock Send Frogram Data Files Scheduled Collection Wizard Complete 4 Previous Next f Cancel Connection Help Figure 10 Select the connection type Select Next E Setup Wizard CR amp 00Series CR amp 00Series Progress COM Port Selection Introduction Select the computer s COM Fort Communication Setup Communications Port COM1 z where the datalogger iz attached i Communications Port COM1 Datalogger Settings ommunications Po Setup Summary noe COM Port Communication Delay Fusing an SCADA device you may Communication Test oo J need to have a delay before A communication Is attempted on the Datalogger Clack COM port This will allow the PC to a load the appropriate drivers 2 to 4 Send Program seconds should be enough Data Files Scheduled Collection Wizard Complete Figure 11 Select the Com Port the logger is connected to Note If the cable is correctly attached to the PC and the driver has been installed correctly it will be listed in the drop down box If the cable is not shown please use Device Manager in windows to identify the correct Com port or diagnose any issues Once this has been done close and then reopen the Setup window and the EZSetup wizard Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingd
15. w Cysom Station Statur Fie Contol Num Display Graphs Ports amp Flags Shahan r i eal f Ea Srian Okka Advvied Serer Doe Tima ZANAN Vode Os Staton Dae T ene JAA Ved za aai 1405 1 273 Pane Check Update LT lake Program ay 2077 273V0 00 0R8 12 23508 24 MG Sond Wola Mus Syl 711216 uiian biei SoZ EEEE Hotes me m ET E 389 616 Siran Wi SGH 28 BLE uStrasin_Muxl_SGf5 468 016 asian Musil Sate A FIE isian Bil Sa O34 1b airan uxt Sei S616 Lra Mir Sji 58 Linea Min SGI 442 94 Liami Mure SiG 3 Lines Mui SGA Liew Mul SGS Linea _Mun1_SGJE Linear Miun1 SGIM Linas Wuni SDE Tengetatiue Mul Saji 4 8 Temperature Misi S62 2 57 td Tenrgecatue Mii _ S63 1 46 9753 Temperate Mui Sejid 146 9753 Tempeseture_ Mie _ SEH 1402405 Tempezstue_ Mun SGE 141 5a Temperatue Mun Hafi 141 Od a ay Temperature Mun SGI AN Bu 0 00 01 05 Sel Figure 16 Once connected select the Public table Bell Lane Uckfield East Sussex t 44 0 1825 765044 e info itmsoil com TN22 1QL United Kingdom f 44 0 1825 761740 w www itmsoil com Itmsoil Holdings Ltd Registered in England Number 4239206 Registered Office Bell Lane Uckfield East Sussex TN22 1QL itmsoil INSTRUMENTS The details within the public table will differ for every data logger Though the features that are consistent are A RecNum B TimeStamp C ProgVer D LoggerlD E Measintv F DoMeas This
16. will tell you how many scans have been performed since the logger has been switched on This will not indicate how many readings have been taken but how many times the program has checked if the DoMeas is true This will usually scan every minute see A on Figure 16 This will display the current time set in the logger This can be adjusted to the time of the PC connected to the logger by using the Set button in the top right corner see B on Figure 16 The current version of the program see C on Figure 16 The last three digits of the logger identification number see D on Figure 16 The measure interval in minutes This can be set by clicking on the number and retyping the number of minutes you wish to set the interval to then pressing enter In most cases this can be set between 1 to1440 minutes If set out of this range it will reset to the default measure interval the interval asked for when the logger was purchased When the logger is turned off and back on this will also reset the measure interval to its default see E on Figure 16 When this is true the logger will take a reading on the next scan in most cases this will be on the next minute This will be true when the logger is first powered on This can also manually be set to true by clicking on false typing true then pressing enter see F on Figure 16 The other values shown will mainly be the most recent readings These can be associated with the wi