User Manual Motion Detector Infra Garde 200 UP Acoustic
Contents
1. connected in parallel approx 5 1000 Lux 180 8 m frontal 5 m lateral 80 x 80 x 30 mm visible IP20 indoors class ll
2. response may vary depending on the installation site floor heating hot environment etc Manual switch OFF AUTO ON As with a regular light switch the light may be switched OFF left or ON right permanently The middle position will switch lighting automatically Troubleshooting error cause amendment light does not turn on twilight adjustment value set too high check light fitting and lamp check mains power fuses detector triggers without check detection area for errors draught reason light never turns off animals heating may cause faulty switching check distances to lamps heat reflection or direct light influence check vicinity for background noise and ad just microphone sensitivity connect RC element in parallel to transfor mers relays electric ballast turns the light on during twilight adjustment set too low daytime Electronic Control Induction in long installation wires if several detectors connected in parallel may generate a considerable capacitive current on the switched phase For electric loads using only a small control current such as staircase timer switches this may lead to permanent switching or general malfunctions In order to minimise the capacitive current an RC element may be connected in parallel to the load Alternatively a contactor which is more tolerant to capacitive currents may be installed before the load We recommend a maximum of four detectors
3. User Manual Motion Detector Infra Garde 200 UP Acoustic Warning Any work on the main power supply must only be completed by trained specialists The product must be installed in accordance with installation guideli nes standards specific to your country Disconnect the 230V power supply before starting the installation process The device s power supply must always be fitted with a 250VAC 10A type C fuse in accordance with EN60898 1 The device must not be installed on conductive surfaces The device is suitable for indoor installation only Disconnect power prior to replacing a lamp Faulty lamps may cause a short circuit and thereby permanently damage the device To ensure the operational reliability of the detector keep a minimal distance of 1m to lamps installed on the same height level Lamps installed underneath the detector or in the detection area may impair functionality Keep away from heating devices In case of malfunction such as continuous lighting or false triggering please refer to the troubleshooting section on this page Function The detector reacts to the motion of heat positive or negative in relation to the environment If a person approaches the monitored area the device will turn on the connected light automatically If the person leaves the area the light will be switched off after the preset duration short impulse 30 sec to 20 min The in built microphone extends the delay time while li
4. ghts are still on as well as during a maximum 10 seconds after lights switch off The connected light will be turned on only when the ambient light value is below the adjusted value Installation Install device at regular light switch height between 100 and 150 cm N L Peli haie A Wire the detector as follows phase outer conductor L brown neutral neutral conductor N blue switching output switched phase outer conductor LT Optional remote switching S through impulse switch without pilot lamp phase to terminal S Keep wire as short as possible Capacitive current at terminal S may cause malfunctions Special function 2x impulse at terminal S within 2 sec 6 h of permanent light followed by AUTO operation 1x impulse during permanent light returns device to AUTO operation 1m am 5m IN iN Os 10m xt 4e NO N 3 TL OFF TEST TIME VOICE LUX TIME Set up delay time for lights on time period after last movement detection Choose between impulse function for staircase switches 30s 1m 3m 5m 10m 20m VOICE microphone Activate in built microphone to extend delay time during lights on without additional movement detection or visual contact max 10 seconds after lights switch off Each detected noise re triggers set delay time Middle position detects normal talking volume maximum setting detects whispers LUX twilight sensor Controls light value from which motion detection triggers lig
5. hts on Moon symbol activation at night sun symbol activation during daytime TEST detection area check with short delay time Technical Data Nominal power 230V 50Hz Twilight switch Switching power max 1000W 5A cos 9 1 Detection area max 250VA 1 25A inductive Dimensions Time adjustment impulse 30 s to 20 min IP protection Microphone adjustable 45 70 dB Connection of electrical loads High inrush currents will considerably shorten the lifetime of the detector s in built relay Please verify the technical data provided by the lamp or lumi naires manufacturer concerning inrush currents specifically with compact fluorescent fluorescent lamps electronic ballast etc in order not to over load the internal relay We recommend connecting a maximum of three to four motion detectors in parallel If the number of switching cycles is above average or in the event of increased inductive loads we recommend using the short pulse function on the motion detector and switching the load via an external staircase timer switch or contactor Detection Range frontal detection NOT SENSITIVE detection range approx 50 max 10m tangential detection SENSITIVE max 8m The detection range depends on the installation height and walking direction high sensitivity when cutting or changing a switching segment Since the detector reacts to temperature differences between heat source and ambient temperature the
Download Pdf Manuals
Related Search
Related Contents
Fostex X-12 User's Manual Kidde KN-COB-B-LPM User's Manual DANGER - Kitagawa Europe Cooler Master RC-310-RWN1-GP computer case 三菱電機 Copyright © All rights reserved.
Failed to retrieve file