Home

CTV 110 - HITMA Instrumentatie

image

Contents

1. 7 eee setting in air velocity Configurations From 0 to5m s From0to10m s From0to15m s From 0 to 20m s From 0 to 30 mis switc To set a measuring range put the on off i 1 B 1 1 O 1 switches 1 2 and 3 as shown beside Combinations im 2 2 2 M 2 im 3 E 3 E 3b ok 3 J __ E E ef gt Setting of temperature unit switch 2 Configurations C F To set the temperature unit put the on off switch 4 of the unit as shown beside i E Combinations f f 4 B i oo gt Outputs setting in temperature switch 2 Configurations From 0 to 50 C From 20 to 80 C From 50 to 50 C From 0 to 100 C From 0 to 200 C To set a measuring range in 1 1 1 1 1 temperature put the on off switches 1 _ a Combinati 2 2 W 2E 2 E B 2 and 3 of the measuring ranges as ombinations a shown beside 3 L__ 3 3 M 3 WO 3 WO j I 4 i J _ CONFIGURATION VIA LCC S SOFTWARE option An easy and friendly configuration with the software 1 You can configure your own intermediary ranges 9 Example for a 0 30 m s transmitter the minimum delta of the range is 5 m s The instrument could be then configured from 5 to 10 m s 3 e To access the configuration via software 4 Set the DIP switches as shown beside Connect the cable of the LCC S to the connection of the transmitter Switch 1 e Please refer to the user manual of the LCC 100 to make the configuration The configuration of
2. the parameters can be done either with the DIP switch or via software you can not combine both solutions 75 mm MOUNTING To mount the transmitter mount the ABS plate on the wall drilling 6 mm screws and pins are supplied Insert the transmitter on the fixing plate see A on the drawing beside Rotate the housing in clockwise direction until you hear a click which confirms that the transmitter is correctly installed 23 75 mm 68 mm air velocity probe Positioning of the measuring element in the air flow The probe must be placed perpendicular to the air flow as shown beside For the duct mount probes it is possible to place the probe s head front of the air flow and keep the housing straight gt Locate the red point marked on the probe s head gt Remove the screw located on the tip of the probe s body gt Rotate the probe s head by turn 1 2 turn or turn in order to place the red spot front to the air flow gt Replace the screw on the probe s body head of the probe sensitive element air velocity sensitive element temperature Sse red spot mark screw The red point on the probe s head is a mark that must be placed face to the airflow Then the probe is perpendicular to the airflow air flow direction MAINTENANCE Please avoid any aggressive solvent Please protect the transmitter and its probes from any cleaning produ
3. KIMO INSTRUMENTS Temperature and air velocity Technical Data Sheet Pressure Temperature Humidity Air Velocity Airflow Sound level CE Ey transmitter e CTV N10 mg KEY POINTS oA Measuring range from 0 to 30 m s and from 0 to 50 C m 0 10 V or 4 20 mA output active power supply 24 Vac Vdc 3 4 wires E ABS V0 housing IP65 with or without display Alternating display of air velocity and temperature ge S Ya turn system mounting with wall mount plate P j Housing with simplified mounting system b a D l FEATURES OF THE HOUSING s 46 mm 150 mm ou 300 mm Duct model Material ABS V0 as per UL94 Protection IP65 Display LCD 10 digits Size 50 x 17 mm Alternating display of air velocity and temperature 46 mm PART NUMBER To order just add the codes to complete the part number Oo _ _ active 4 20 mA with display and remote probe of 150 mm length CTV110 Remote model TTE Height of digits i Values 10 mm E Units 5 mm e 13mm Cable gland For cable 8 mm maximum 109 mm Weight 164g Cable of remote probe length 2 m and 4 8 mm in PVC Example CTV 110 AOD150 CTV110 temperature and air velocity transmitter Probe A Duct Power supply Output l D Remote Probe length A Active 24 Vac Vdc 4 20 mA Display 150 150 mm V Active 24 Vac Vdc 0 10 V O with display yee N with
4. al gases From 0 to 50 C From 10 to 70 C ELECTRICAL CONNECTIONS as per NAC 5 700 standard A This connection must be made by a qualified technician To make the connection the transmitter must not be energized For CTV110 VNA CTV110 VND CTV110 VOA CTV110 VOD models with 0 10 V output active A To make a 3 wire connection before powering up the transmitter please connect VT GND W b a f s 1 2 3 4 6 Regulator display or PLC BMS passive type 0 10 V output 4 wires the output ground to the input ground See drawing below VT GND W Power supply 24 Vdc Regulator display or PLC BMS passive type OF Power supply 24 Vac class II VT N 4 class IlI Regulator display or PLC BMS passive type 3 wires 0 10 V output For CTV110 ANA CTV110 AND CTV110 AOA CTV110 AOD models with 4 20 mA output active IT GND IV To make a 3 wire connection before powering up the transmitter please connect the output ground to the input ground See drawing below PLC BMS active type gt 4 20 mA output Regulator display or Power supply 24 Vac Bro eh ACNEE Regulator display or class II 4 20 mA output PLC BMS active type 4 20 mA output 4 wires 3 wires CONNECTIONS A N Fixed back housin Inside the front housing Removable front face o g E sect a n Eira s aP r Power supply terminal block LCC S Switch 2 Switch 1 connecti
5. ct containing formalin that may be used for cleaning rooms or ducts OPTIONS AND ACCESSORIES e KIAL 100A Power supply class 2 230 Vac input 24 Vac output e LCC S configuration software with USB cable e Sliding fittings mounting brackets wall mount support for hotwire probes Distributed by afaQ EXPORT DEPARTMENT Tel 33 1 60 06 69 25 Fax 33 1 60 06 69 29 e mail export kimo fr ISO 9001 Qualit AFNOR CERTIFICATION FTang transmitter_CTV 110 08 03 13 RCS 24 P rigueux 349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice
6. on S2 S1 Cable gland SETTINGS AND USE OF THE TRANSMITTER gt Configuration It is possible to configure the measuring ranges and the units of the transmitter via switch and or software To configure the transmitter it must not be energized Then you can make the settings required with the DIP switches as shown on the drawing below When the transmitter is configured you can power it up Confi tion b itch On off switch gt Configuration by switc wo a To configure the transmitter unscrew the 4 Screws from the housing then i Eia Pie _ ne range open it DIP switches allowing the different settings are then accessible 2 setting 2m setting W 7 WE Please follow carefully the combinations beside with the DIP switch If the ae T t t A combination is wrongly done the following message will appear on the a ti a a oa uni display of the transmitter CONF ERROR In that case you will have to Switch 2 Switch 1 unplug the transmitter place the DIP switches correctly and then power the transmitter up Configurations gt Air velocity unit setting switch 1 To set a measurement unit in air velocity put the on off switch 4 of the units as shown Combinations in the table beside
7. out display TECHNICAL FEATURES IN TEMPERATURE Measuring range Accuracy Unit of measurement Response time Type of sensor Resolution Type of fluid From 0 to 50 C possibility to set the output on the following ranges from 20 to 80 C from 50 to 50 C and from 0 to 100 C 0 3 of reading 0 25 C 5G 1 e 63 5 s Pt100 1 3 DIN 0 1 C Air and neutral gases All the accuracies indicated in this technical datasheet were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with calibration compensation TECHNICAL FEATURES IN AIR VELOCITY Outputs settings From 0 to 5m s from 0 to 10 m s from 0 to 15 m s from 0 to 20 m s and from 0 to 30 m s Accuracy From 0 to 3 m s 3 of reading 0 05 m s From 3 to 30 m s 3 of reading 0 2 m s Units of measurement m s and fom Response time 1 e 63 2 s Resolution 0 1 m s Type of fluid Air and neutral gases TECHNICAL SPECIFICATIONS Output Power supply active sensor 0 10 V or 4 20 mA alim 24 Vac Vdc 10 3 4 wires maximum load 500 Ohms 4 20 mA minimum load 1 K Ohms 0 10 V Consumption 40 mA 0 10 V or max 80 mA 4 20 mA Electromagnetical compatibility Electrical connection PC communication Environment Operating temperature Storage temperature EN61326 Screw terminal block for cables 0 05 to 2 5 mm Kimo USB mini Din cable Air and neutr

Download Pdf Manuals

image

Related Search

Related Contents

2000 chevrolet venture owner`s manual    Hustler X-ONE General Service Manual  Section 15 - Melt-Disk System - Mold  Wireless N300 Router RNX-N300RTV2 User Manual  manual de instalaçào da placa controladora de alarmes pca  Kenwood DPX-MP4100 CD Player User Manual  Eaton P5MLP1 rack accessory  see manual  Untitled  

Copyright © All rights reserved.
Failed to retrieve file