Home

CAT-40G / CAT-40G-TA

image

Contents

1. Max Label Roll Size Power Supply 12Kg 26 5Lb 400mm 16 diameter Input 220 240VAC 50 60HZz Output 24VDC 4 17A SET UP CAT 40G TA First install the tension arm referring to the enclosed TA User Manual 1 Mount the 400 mm 16 diameter Flange Plate onto the Quick Chuck Core Holder using the screws provided 2 Slide the Quick Chuck and Flange Assembly onto the CAT 40G Motor Shaft allowing for clearance to the Chassis and Motor Screws Tighten the Allen screw to secure the Quick Chuck and Flange Assembly onto the flat part of the Motor Shaft 3 Set the CAT 40G in place near the label exit slot of the printer 4 CAUTION AVOID ACCIDENTS THE CAT 40G WEIGHS APPROXIMATELY 13 6KG 30 POUNDS SO CHOOSE ONLY A STURDY SURFACE ON WHICH TO SET THE UNIT 5 The CAT 40G is bi directional It can rewind labels in either direction 6 Verify that the DIRECTION Switch on the CAT 40G Control Panel is in the OFF position 7 Plug the Power Plug at the end of the wire on the AC Wall Transformer into the CAT 40G Power Input Jack Plug the AC Transformer into an appropriate AC power outlet 8 The unit is now ready for use POWER REWINDING 1 Place the DIRECTION Switch on the CAT 40G Control Panel in the centre OFF position 2 Slide an empty label core onto the CAT 40G Quick Chuck 3 Feed the label web from the printer under the Sensor Arm TA only and onto the rewind core and secure it wit
2. MAINTENANCE Your CAT 40G requires no maintenance Product Limited Warranty All Labelmate Products are warranted to the original end user customer to be free from defects in materials and workmanship If it is determined by Labelmate that a product has failed under the terms of this warranty the product will be repaired or replaced at no charge to the customer Labelmate reserves all rights to determination of coverage and liability under this warranty The warranty period for all new Labelmate products is outlined below Warranty Period Products Covered Label Rewinders oe Label Unwinders Label Counters mechanical parts only Label Slitters mechanical parts only Label Dispensers Printer Mechanisms Power Supply Modules Counter modules Encoders Any products not specified above The warranty period for all products starts on the date purchased by the original end user customer Warranty coverage is not transferable with ownership and will terminate immediately upon rental resale or any other change in ownership This warranty does not cover repair to any product which is damaged has been modified is missing parts or has been opened or repaired by any unauthorised person Use of any unauthorised accessory or attachment will void coverage Purchase documentation should be retained for coverage verification In the event your product requires service please contact the distributor you bought the product from The custo
3. h a piece of tape 4 Place the DIRECTION switch in the desired position to rewind the labels 5 Advance the TORQUE Control about 1 3 rotation from fully counter clockwise as an initial setting 6 Start your printer and observe how the labels are being rewound 7 Adjust the TORQUE Control as needed to provide more or less rewind force The CAT 40G s amplified torque motor will provide a nearly constant rewind speed as the roll diameter grows If necessary adjust the rewind TORQUE setting A WARNING This Product is for indoor use only Not for use in wet locations EXTERNAL HALT CONTROL The External Halt Control jack on the CAT 40G is for use with external devices capable of providing an open circuit halt command A 3 5mm control cable is necessary for use not included Use of the External Halt Control circuit is optional With No Connection nothing plugged into the External Halt Control jack the Rewinder will function as described above With Pin 2 and Pin 3 of the External Halt Control circuit closed connected together using a 3 5mm dual circuit plug the CAT 40G will operate When the External Circuit is opened the CAT 40G will stop 3 5mm EXTERNAL HALT CONTROL Plug Dual Circuit Plug Contact CLOSED RUN Contact OPEN HALT Pin 1 No connection NOT USED Pin 2 Normally Closed NC contact Pin 3 Normally Closed NC contact return 12V EXT HALT CONT 49K 1 2 3 3 5 mm Jack l Dua
4. l Circuit 10K
5. mer assumes responsibility for all cost and risk incurred in transport for service Labelmate makes no other warranty of any kind expressed or implied or to suitability or fitness for a particular purpose No other person agent or reseller is authorised to give any warranties on behalf of Labelmate Any obligation to warranty other than that specifically addressed above is hereby disclaimed LABELMATE LLC 69 AVENUE ALPHONSE XIII 1180 BRUSSELS BELGIUM TEL 322 375 69 60 FAX 322 375 38 96 brussels labelmate com www labelmate com LABELMATE User_CAT 40G 02 07 CAT 40G CAT 40G TA 40 cm 16 High Torque Gear Driven On Demand Label Rewinder e Switched Dual Torque Range and Direction Controls Constant Adjustable Torque CAT technology e Adjustable Speed Control of min 360mm 14 per second CAT 40G e Precise Variable Torque Control On demand Rewinding Turns Off when Labels Stop Coming from Your CAT 40G TA Printer TA only Remove all parts from the shipping container and verify contents Package Contents e User Manual this document e CAT 40G Drive Unit e Power Supply Module e LABELMATE Quick Chuck Quick Locking Core Chuck e Allen Wrench e Plastic Flange Plate e Tension Arm CAT 40G TA only Retain the Shipping Container and Packaging for Storage and Transport e KEEP MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE e SPECIFICATIONS Max Label Roll Weight

Download Pdf Manuals

image

Related Search

Related Contents

Product Manual  MOXF - A Universe OF sOUnds FrOM A decAde OF  取扱説明書    3 - Online Demos  Murphy DF Series User's Manual  DC150 Manual de usuario (E)  Fujitsu ESPRIMO P5925  wing_designer_manual V1.1  zBoost Xtreme REACH ZB560SL User Manual  

Copyright © All rights reserved.
Failed to retrieve file