Home

RTU5305 GSM Air-Conditioner Controller User Manul

image

Contents

1. 15 10 Maintenance 15 11 Quality Warranty 15 This handbook has been designed as a guide to the installation and operation of RTU5305 GSM SMS IR Controller Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation work commences Honghui Electronic Co Ltd its employees and distributors accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook Honghui Electronic Co Ltd its employees and distributors accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook h h http www honghuigsm com 0 n A U 4 S Mm http www gsmmmsalarm com WUW HONGHUIGSH COH honghuigsm gmail com 1 Brief introduction The GSM SMS IR Controller RTU5305 is a very simple device which c an be used for authorized temperature monitoring remote control Air Conditioner Actually the GSM SMS IR Controller RTU5305 can be used in places which require to use Infrared Remote to control e g Air Conditioner Temperature Monitoring Automatically monitoring temp
2. Com Dout2 Normal Open Output Relay 5 Features 1 1 temperature diode 25 10K 1 precision included in standard package input to convert the temperature to digital value 2 Lower or Higher warning temperature threshold value can be configured 3 Can inquire the current temperature value in C to mobile phone by SMS Command e g 21 C 4 Can be configured parameters from anywhere by SMS Text command no distance limit 5 Automatically Switch ON OFF Air Conditioner while temperature exceeding the preset range 6 Up to 5 different temperature value can be configured by SMS commands 7 Up to 5 phone numbers can be configured as SMS Text warning receiver 8 External AC Power failure and recovery can warn the users 9 1 Digital Output Relay 3A240VAC NC and NO can be used for remotely switch ON OFF equipments by SMS Text Command Also the relay can be linked to the temperature threshold value e g when temperature is lower or higher than the threshold value then switch ON or OFF the output http www honghuigsm com O h 0 n H h U g S Mm http www gsmmmsalarm com WWW HOMNGHUIGSM COM honghuigsm gmail com relay automatically 10 Secure Using password for identification authorized users 11 Based on GSM Network applied to many applications 6 Settings SMS Commands 1 2 3 4 5 6 8 9 The default Password is 1234 All the settings are through SMS commands plea
3. Learning This button for learning IR Air Conditioner s Infrared Remote Transmitter T1 Position Led when learning IR signal to T1 will flick after learned successful Led OFF T1 6 will always on T1 Led off T2 Led on then learn to IR signal to T2 Position T3 T6 The same as T2 the other Led will off Pre ss learning button to loop T1 to T6 one by one Switch on GSM SMS IR Controller Off Registered GSM Network successful Always Green Registered GSM Network failure Off Enter to Learn IR Signal Mode Red Learning IR Signal Red and Green Receiving and Sending SMS Green and flick red color Learning IR Receiver while learning the IR Signal t he IR s IR Transmitter must face this IR Led IR TX IR Transmitter must face the Air Conditioner s IR Receiver h h http www honghuigsm com 0 n A U l 4 S Mm http www gsmmmsalarm com WWW HONGHUIGSH COH honghuigsm gmail com anaa S _ a Interface Instruction 2 IR TX IR Transmitter must face the Air Conditioner s IR Receiver The same as another one SIMCard Put SIMCard inside GSM ATN Install the GSM Antenna Temperature Diode connector non Polar Temp Temperature Diode connector non Polar DIN Reserved useless DON feos O N Optional Power Socket Output 12VDC from GSM SMS IR Controller to external device or power on the GSM SMS IR Controller from external power source Doutl Normal Close Output Relay
4. Before installing the GSM SMS IR Controller please help to test the system firstly including power supply gsm signal etc 7 1 Insert SIMcard into GSM SMS IR Controller In one side of the GSM SMS IR Controller pleas e install the GSM SIM card and GSM Antenna R 2 7 2 Learning IR Transmitter signal to GSM SMS IR Controller Press the Learning Button and switch on the GSM SMS IR Controller then loose it and the GSM SMS IR Controller will remove all saved IR Transmitter signals at T1 T6 And enter into learning mode The T1 Led will flick and the Status Led will be red and green color AO rd Change Temperature 1 ra Value Button j q 4 oO TT H L al fo ON OFF Button OT 12 honghuigsm att rp WWW HOMGHUIGSM COM honghuigsm gmail com hui sm mail com Step2 Press the Learning Button till the Status Led change to green and T1 Led flicking Then press the IR Infrared Remote of the Air Conditioner function button The one what you want to learn to the GSM SMS IR Controller for T1 it is special for the ON OFF function So please press the switch ON OFF button when T1 Led change always on and Status LED turns off then means the learning IR Signal to GSM SMS IR Cont roller T1 position operation successful Press the Learning Button again T1 LED will off T2 Led will flick press the IR function button when T2 Led change to Green and Status LED turn s off then means the learning IR Signal to GSM SMS
5. HONGHUIGSM COM honghuigsm gmail com 8 Non Link the Air Conditioner when low temperature alarm occurrence PAATTI Reply Tips The Non Link Air Conditioner and Non Link the relay output when low temperature alarm occurrence is default 6 7 Setup High Temperature Alarm Value and Actions 1 Enable high temperature alarm function pwdH HIGH ON Reply When high temperature alarm occurrence will send SMS Alarm High Temperature alarm to the owners 2 Disabled High temperature alarm function Reply 3 Setup High temperature alarm value Reply 4 Switch On the Relay Output when High temperature alarm occurrence pwdH HIGH RON Reply 5 Switch OFF the Relay Output when High temperature alarm occurrence PTO Reply 6 Non Link the Relay Output when High temperature alarm occurrence Pwd HIGH RNO Reply 7 Switch On the Air Conditioner automatically when High temperature alarm occurrence h a http www honghuigsm com 0 n z U 4 S Mm http www gsmmmsalarm com WW HONGHUIGSM COM honghuigsm gmail com Reply Tips The Tx is the same means of abovementioned x 1 6 Please pay attention to the T1 is special for OFF Value 8 Non Link the Air Conditioner when High temperature alarm occurrence PTT Reply Tips The Non Link Air Conditioner and Non Link the relay output when high temperature alarm The Air Conditioner is not link to High temperature
6. IR Transmission about 2 3m Size 85mm 103mm 15mm Net Weight 0 50Kg http www honghuigsm com W h 0 n z h YJ 4 S Mm http www gsmmmsalarm com WWW HONGHUIGSM COM honghuigsm gmail com 9 Important information 1 Please read the User Manual carefully before you install the GSM SMS IR Controller and set the GSM SMS IR Controller 2 Install the system in a hidden place 3 Avoid getting water into the GSM SMS IR Controller 4 Have a secure connection to the main power supply 10 Maintenance 1 In case of failure please cont act the distributor or manufacturer 2 Ifthe remote control works but the GSM SMS IR Controller fails to send SMS texts switch the power of GSM SMS IR Controller off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 Ifthe GSM SMS IR Controller can run and sens ors work but cannot send SMS texts please change SIM Card to check it 4 Ifthe problem cannot be solved please contact the distributor or manufacturer 11 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers The End Any questions please
7. 1 The in the commands is means t he password when you use it please in stand of it by the digital number the capital letters is the command letter use directly 2 Remember that commands must be CAPITAL Lock LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method 6 2 Setup Authorized number E g if you want to setup 13500001111 as the firs t user number and the password is 1234 then you can send 1234 TEL004413500001111 014 to the RTU5305 unit After the RTU5305 received the 0044 is country code will return h h http www honghuigsm com 0 n A U l 4 S Mm http www gsmmmsalarm com WWW HONGHUIGSH COH honghuigsm gmail com Tips 1 the authorized number means the one who can receive the RTU5305 unit warning SMS text 2 We strongly recommend that these numbers are cellphone numbers because of the alarm message only send by SMS text 3 The Serial Number is the position to store the authorized number from 01 05 6 3 Remove the Authorized Number or you can overwrite with another number you wish to change it E g if you want to remove the authorized number at position 05 and the password is 1234 then you can send L234 TEL 05 6 4 Inquiry the Authorized Number 6 5 Inquiry the assigned IR value information After the RTU5305 received will return T
8. IR Controller T2 position operation successful Tips The Switch Button on IR s panel only used for switch off the Air Conditioner in the RTU5305 Please learning this button to T1 Position The buttons on IR s panel had used for switch on the Air Conditioner and setup the temperature at T2 T6 positions Learning 20 C to T2 position You can following below steps 1 Change the IR Value to 19 C or 21 C firstly then Press the GSM SMS IR Controller learning button it will flick T1 firstly press again it flicks T2 when the T2 Led flicking and Status Led is Red and green color then press the on the IR s panel to change the temperature to 20 C button After the GSM SMS IR Controller received the signal will save it at position T2 2 When you want to learn the Switch OFF butt on function to the GSM SMS IR Controller then press the Learning Button when the T1 Led flicks and status led is red and green color then press the Switch Button the GSM SMS IR Controller will receive this signal and save at position T1 3 So when you send SMS command pwd Tx the GSM SMS IR Controller will switch on the Air Conditioner and change to Tx temperature if you want to change its temperature then you can send SMS command to change it again 7 3 Connecting the temperature diode 25 10K 1 precision included in standard package the connector points are Temp and Temp the temperature diode is non polar Lja http www
9. alarm occurrence 6 8 Switch ON the Relay Output Reply Tips The Relay output cannot work while external AC Power goes off The SMS Command has priority over the Link configurations e g when setup Switch On the Relay Output when High temperature alarm occurrence function and happened the relay output will switch on but when the GSM SMS IR Controller received the SMS command pwd DD the relay output will switch off Immediately 6 9 Switch OFF the Relay Output Reply 6 10 Switch ON Air Conditioner and setup its temperature The Tx stands for T2 T6 T1 is special for switch off the air conditioner please see 6 11 For example send pwd T2 to switch on the air conditioner and se tup the temperature as T2 position value will return Temp set2 is En Send pwd T3 to change the air conditioner temperature to T3 Position Value will return Temp set3 is En If the Tx haven t been assigned any IR value after send pwd Tx to the GSM SMS IR Controller will ll h h http www honghuigsm com 0 n 7 U 4 S Mm http www gsmmmsalarm com WH HONGHUIGSM COM honghuigsm gmail com Return Tx eg if the T6 Position hasn t been assigned the IR Value then after send pwd T6 to the GSM SMS IR Controller will return The T1 T6 value can be assigned to the GSM SMS IR Controller by used the Air Conditioners IR Transmitter 6 11 Switch OFF Air Conditioner 7 Operation amp Installation
10. erature with Air Conditioner at preset temperature range Moreover the GSM SMS IR Controller RTU5305 equips with a relay output can be used in places which require turning ON OFF your system machines equipments remotely with a SMS Text command from your mobile phone What Applications does the GSM SMS IR Controller RTU5305 suitable for Air Conditioner TEA 2 x Current temperature is 180C relay is off AC power is on Ties FETE pi Xu Alarm Low temperature Alarm gee Regulation GSM Air Conditioner Controller ull CB 23 00 The high Tem perature temperature alarm Switch Control lue is 320C Control Alarm KA EN Set Temperature http www honghuigsm com O h 0 n z h U 4 Mm http www gsmmmsalarm com ST SS honghuigsm gmail com 1 Temperature Monitoring alarm application e g Send SMS to inquiry the current temperature 2 Air Conditioner Remotely management e g Switch ON Air Conditioner and setup the temperature value 3 Infrared Remote Control equipments e g Switch on Off the Air Conditioner 4 Warehouses and Laboratory room e g Monitoring the temperature higher or lower should send SMS warning to owners 5 Automatically monitoring the temperature within the preset range e g Higher than 25 C should automatically switch on Air Conditioner and send SMS to owners low than 10 C should automatically switch on the heater Air Conditioner to heat u
11. help to contact us feel free Email honghuigsm Gmail com Http www honghuigsm com Http www gsmmmsalarm com 15
12. honghuigsm com h 0 n A h U f 4 S Mm http www gsmmmsalarm com WW HONGHUIGSM COM honghuigsm gmail com 7 4 Connecting the Electricity equipments The GSM SMS IR Controller supports 1 Digital Output Relay 3A240VAC NC and NO it can be used for remotely switch ON OFF equipments by SMS Text Command Also the relay can be linked to the temperature threshold value e g when temperature is lower or higher than the threshold value then switch ON or OFF the output relay automatically When contact Doutl and COM it is Normal Close type When contact Dout2 and COM it is Normal Open type please see below Temperature Diode NC Type Connection NO Type Connection 7 5 Install the Mainframe The mainframe should be installed which the IR TX facing the Air Conditioner IR Receiver to ensure the IR transmission range and there re with a power source as well as enough GSM signal coverage The distance from the GSM SMS IR Controller must be less than 3meters to the Air Conditioner 8 Technical specifications Rated Voltage 9 24VDC 1A Working temperature 10 C 55 C Storage temperature 20 C 60 C Relative humidity 10 90 No condensation Work frequency 900 1800MHz Default or 850 1900MHZ Communication protocol GSM PHASE 2 2 include data service Related Voltage of the Output Relay 3A 240V AC Max 600W Backup Battery Life Last 12hours in standby mode Power Consumption Standby lt 20MA Working lt 1500MA
13. http www honghuigsm com honghyigsm penn emer O hd aa ale com E a Automatically monitoring Air Conditioner by SMS Text Remotely Control Air Conditioner by SMS Text Temperature Monitoring by SMS Text ssm Air Conditioner Controller Set GSM Controller No First i GSM SMS IR CONTROLLER RTU5305 User Manual Ver 1 0 Date Issued 2012 02 08 All rights reserved by Honghui Electronic Co Ltd Website Http www honghuigsm com h a http www honghuigsm com 0 n z U 4 5 Mm http www gsmmmsalarm com WH HONGHUIGSM COM honghuigsm gmail com Table of contents 1 Brief introduction 2 2 Safety Directions 3 3 Standard Packing list 4 4 Physical Layout 4 5 Features 5 6 Settings SMS Commands 6 7 Operation amp Installation 12 8 Technical specifications 14 9 Important information
14. ips The GSM SMS IR Controller can be saved 5 different temperature value The T1 position is for assigning IR ON OFF Air Conditioner value the T2 T6 positions are for assigning IR Temperature value h a http www honghuigsm com 0 n z U 4 S Mm http www gsmmmsalarm com WH HONGHUIGSM COM honghuigsm gmail com 6 6 Setup Low Temperature Alarm Value and Actions 1 Enable low temperature alarm function pwd LOWHONH Reply When low temperature alarm occurrence will send SMS Alarm Low Temperature alarm to the owners 2 Disabled low temperature alarm function Reply 3 Setup low temperature alarm value Reply Notice While setup the low or high temperature value please don t include the unit C in the command 4 Switch On the Relay Output when low temperature alarm occurrence pwd LOW RONE Reply 5 Switch OFF the Relay Output when low temperature alarm occurrence pwd LOW ROFFH Reply 6 Non Link the Relay Output when low temperature alarm occurrence pwd LOW RNOF Reply 7 Switch On the Air Conditioner automatical ly when low temperature alarm occurrence Reply Tips In Tx the x 1 6 Stands for T1 T6 This command means when low temperature alarm will switch on the Air Conditioner with Tx temperature Please pay attention to the T1 is special for OFF Value http www honghuigsm com h 0 n z h YJ 4 S Mm http www gsmmmsalarm com WWW
15. nly caused by incorrect phone number format please try to add the country code before the number see the below settings h a http www honghuigsm com 0 n z U 4 5 Mm http www gsmmmsalarm com WWW HONGHUIGSM COM honghuigsm gmail com For example In UK the country code is 0044 or The user cell phone number is 3408888666 and has been assigned as a SMS Alert number the simcard number in the panel is 3408888555 Problem 1 Alarm but the user haven t received the SMS Alert Solution Please plus the country code while you setup the as SMS Alert number means setup to instead of the l Problem 2 The user number can receive the SMS Alert message from alarm panel but the alarm panel can not receive the commands from the user number Solution Please add country code to the simcard number in the alarm panel Means send sms commands to to instead of Solution 3 When you use cell phone dial another one what number it will be di splayed then you can set the displayed number as dial numbers when you use cell phone send SMS to another cell phone what number it will be displayed then you can set the displayed number as SMS Alert number just use the 00 to replace the also you can try the 6 1 Setup New Password if successful the unit will return Password modified OK For example the original password is 1234 you want change it to 6666 t hen you can send the command below 1234 PWD 6666 Tips
16. p the temperature and warning owners by SMS 6 Switch ON OFF equipments e g motor Air Conditioner and other electronic equipments 2 Safety Directions Safe Startup Do not use GSM SMS IR Controller when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM SMS IR Controller and influence its performance Avoid Use at Gas Station Do not use GSM SMS IR Controller ata gas station Power off GSM SMS IR Controller when it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer h h http www honghuigsm com 0 n A U l 4 S Mm http www gsmmmsalarm com WWW HONGHUIGSH COH honghuigsm gmail com 3 Standard Packing List GSM SMS IR Controller x1 GSM ANT x1 Temperature Diode x1 25 10K 1 precision User Manual x1 CD Connector x1 AC DC Adaptor x1 4 Physical Layout 4 1 GSM SMS IR Controller physical layout Interface Instruction 1 OFF ON Switch ON OFF the unit Reset Press it then switch on the controller the parameters have been reset to default settings
17. se edit the below SMS commands in your cell phone then send to the RTU5305 Unit You can program the GSM SMS IR Controller with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the nu mber of the SIM inserted in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system by chance Remember that commands must be CAPITAL Lock LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method When external AC goes off and goes on will send SMS Tex t AC Power goes off or AC Power goes on to the authorized numbers The SMS commands that you will certainly us e in the GSM SMS IR Controller are the following 6 1 6 11 All return SMS will additional includes current temperature value relay status external power status backup battery voltage value Low Temperature alarm value High Temperature alarm value and link action details When you want to reset the parameters to factory default please Press the Reset Button then switch on the controller after long Di sound alert means the parameters have been reset to default settings In some GSM operators they use different SMS protocols the units can t return the SMS confirmation is normally It is not product problem For this problem mai

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE USUARIO TAXÍMETRO NI-110  Important Safeguards  RNAscope® Fluorescent Multiplex Kit Guide luorescent Multiplex Kit  Barriere anticaduta con parapetti tipo sali  Benutzerhandbuch - inShop.hu webáruház  South Shore Furniture 3113212 Instructions / Assembly  User Manual  iStarUSA WN158  Furuno CH-28 User's Manual  