Home
User Manual - Rainforest Automation
Contents
1. automation Technical Manual Diagnostic Mode Diagnostic Mode provides a number of screens that give you technical details about the EMU and also provide access to advanced functions such as Hard Reset and Firmware Update To get into Diagnostic Mode you must first put the EMU into Configuration Mode This is done by pressing and releasing both buttons simultaneously note that this should not be attempted until the EMU has successfully connected to the smart meter Once in Configuration Mode hold down both buttons for at least five seconds When the buttons are released Diagnostic Mode will be initiated Note that the unit will automatically return to Active Mode after one minute of inactivity www rainforestautomation com rainforest EMU automatio Technical Manual Navigation Flowchart both buttons any button Configuration Node hold both buttons for 5 seconds release Active Sleep Mode p N Mode 4 minutes inactivity i l 1 minute Diagnostic inactivity Mode Device ID screen any button Link Key screen any button Device info screen any button Top ResetDevice Hard screen Reset Bottom Button Top Firmware Update OTA screen Update Bottom Button www rainforestautomation com 11 rainforest a ut om at io n EMU Technical Manual EMU Diagnostic Mode Screens Device ID The Device ID screen shows the Install Code
2. Once the update process has begun it must be allowed to complete uploading the new code in order for the EMU to function correctly After about 20 minutes you should see the progress reach 100 At this point the unit will return to active mode and will reset to activate the update www rainforestautomation com rainforest EMU automation Technical Manual Price Tier indication The EMU has three Indicator LED Lights arranged in a stoplight pattern that is red at the top yellow in the middle and green at the bottom These lights flash even when the EMU is in sleep mode to indicate the current price tier There can be up to 6 price tiers For most tiers a single light will flash the duration and period of the flash depends upon the LED colour e Green 20 millisecond flash every 60 seconds e Yellow 30 millisecond flash every 30 seconds e Hed 30 millisecond flash every 5 seconds The top tier is always considered Critical Peak and is indicated by a double flash of the Hed LED every 3 seconds firs Wer tera tiers der ter5 tere tiers If the number of tiers is 1 or 0 then there is no tier indication flash from the Indicator LED Lights Note that if the price is set manually using the Set Hate screen then the Green Indicator LED Light will flash once every 60 seconds while the manually set price is in effect www rainforestautomation com 23 rainforest EMU automation
3. IN and MAC Address MAC for this particular device Both are 16 digit hex numbers Pressing any button sends you to the Link Key screen Link Key The Link Key screen shows the Preconfigured Link Key for this EMU M It consists of 16 pairs of hex digits Pressing any button sends you to the Device Info screen Device Info The Device Info screen shows the revision number of the firmware FW installed on the device as well as the hardware version HW of the EMU Pressing any button sends you to the Hard Reset screen Hard Reset The Hard Reset screen allows you to perform a Hard Reset by pressing the Top Button Pressing the Bottom Button sends you to the Firmware Update screen Device ID IN ee6d785b8006db6d MAC 00158d00001a56d7 Link Key 8 af a4 da a3 e9 0b 24 93 15 20 0e da a8 74 d2 Device Info HW 3 0 1 FW 1 2 12 3094 Hard Reset Reset Skip www rainforestautomation com rainforest automation Firmware Update The Firmware Update screen allows you to perform an OTA Upgrade by pressing the Top Button Note that this should only be done after carefully reading the Firmware Update section Pressing the Bottom Button sends you Active Mode www rainforestautomation com EMU Technical Manual Firmware Update Update Skip 13 rainforest EMU automation Technical Manual Hard Reset A Hard Reset will erase all existing data and configurations on the EMU The
4. File MAC Address Hex Connect V Skip Verification 00 00 00 00 00 00 00 02 Jennic JN51xx Flash Programmer 1 7 i eg ml c Y Browse Contra d USB Dongle only RESET Donde f nen AT Leg b a Click the COM Port Refresh button and ensure that the correct COM port for the dongle is selected b Click the MAC Address Refresh button and ensure that a Device type and Flash number are indicated above c Click the Browse button to select the BIN firmware image file that you want to load onto the dongle www rainforestautomation com 17 rainforest EMU automation Technical Manual d Select Erase for Programming e Select Use MAC address embedded in application binary f Click the Program button You may see the following warning message If so just click Yes Flash Programmer m e kl i WARNING Invalid MAC address FEFF FE FE FE FE FE FF do you want to amp continue A window will pop up showing the progress loading the dongle followed by another that shows the program being verified Verifying program in flash l X Verifying 3484 blocks of 128 bytes m Elapsed time 0 00 17 Estimated time 0 01 53 Remaining time 0 01 36 Elapsed time 0 00 34 Estimated time 0 01 58 Remaining time 0 01 24 Eventually you will see a message like this Click OK Program successful
5. Technical Manual Prepay Support A firmware option is available for EMU to read the Prepayment Cluster see the Supported Clusters diagram in the About the EMU section in this manual If this is enabled in the firmware build then the Prepayment Information attribute set is read from the meter If the meter provides this information then a new Prepaid Balance screen is shown between the Current Price screen and the Message screen Prepaid Balance 2 503 48 If the meter does not support the Prepayment Cluster the EMU can still receive the Prepaid Balance information by using specially formatted text messages This technique is called Message Tunneling A text message can be sent to the Meter Control System containing the account balance information as well as a time stamp and corresponding meter reading along with the appropriate meter number The Meter Control System can forward the text message in the usual way to the meter and the meter will deliver the text message via ZigBee to the EMU Meter Meter Control Text Message Account Balance Meter Reading Database If Message Tunneling support is enabled in the EMU then the incoming text message is scanned looking for the following pattern PREPAID BALANCE xxx xx mm dd yyyy hh mm ss zzzzzkWh Where e XXX XX Is the account balance in dollars e mm dd yyyy hh mm ss is the date and time stamp e ZZZZZ s the last 5 digits of the meter reading
6. gt 17 4 Connect a Terminal Emulator to the Dongle 19 oO Jonte dM TO Tne Dongle e eese idees eaae rt c ee eben eius 20 6 Upate tie EMO M 22 PCE Tele leit Le E 23 Prepay Support e 24 Price Input OD U CN 26 WICH 0 010 c 26 Text Message ele em 26 ysee feM 27 www rainforestautomation com rainforest EMU automation Technical Manual Regulatory information FCC Notices This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment FCC IC RF Exposure Statement This equipment complies with FCC and Industry Canada radiation exposure limits set forth for an uncontrolled environment The antenna s used for this equipment must be installed to provide a separation distance of at least 8 inches 20cm from all persons ICES 003 Compliance This Class B digital apparatus complies with Canadian ICES 003 Note This equipment has been tested and found to comply with the limits for a Class B digital devic
7. to user error this method is only really practical for flat rate tariffs Text Message Input A firmware option is available for EMU to allow the commodity Price and Price Tier to be set simulating a Price Cluster PublishPrice Command using specially formatted text messages This technique is called Message Tunneling and is much the same as alternative method for Prepay support mentioned in the previous section If Message Tunneling support is enabled in the EMU then the incoming text message is scanned looking for the following pattern CURRENT TIER y x xxxx kWh Where e yisthe Price Tier 1 5 e X XXXX is the Price in dollars 0 0000 9 9999 Using this method will overwrite any Price value that has been set manually using the Set Rate screen This method is particularly useful for implementing dynamic and or Time of Use pricing in deployments where the price cluster has not been enabled in the meters www rainforestautomation com rainforest EMU automation Technical Manual Meter Input The EMU issues a GetCurrentPrice command to the meter every 2 minutes If the meter responds with a PublishPrice Command with pricing information this new Price value will override any value that has been input manually or via text message This makes migration to full in meter pricing transparent and painless www rainforestautomation com 2
8. 24 www rainforestautomation com rainforest EMU automation Technical Manual The information in the text message provides the data necessary for the EMU to provide the Prepaid Balance screen The EMU can even estimate the up to date instantaneous balance between text message updates by calculating the difference in the meter reading from the last update multiplying it by the effective price and subtracting this from the last update balance www rainforestautomation com 25 26 rainforest EMU automation Technical Manual Price Input Options The EMU provides a number of methods to allow the input of a value for the commodity Price This flexibility allows it to work with a variety of smart meter deployment configurations There is a hierarchy of Price input methods Listed highest priority first they are 1 Meter Price Cluster support this input overrides any of the others 2 Text Message parsing this input overrides manual input 3 Manual input this is the default for most deployments This hierarchy makes it easy to migrate from the simplest type of meter deployment no Price support in the meter to more sophisticated Price options with no changes to the EMU Manual Input For smart meter deployments with no pricing in the meter the users can simply enter the commodity price themselves using the Set Rate screen in Configuration Mode as described in the EMU User Manual Besides being prone
9. 3 45 67 89 lt KEY gt lt MAC gt ffffffffffffffff lt MAC gt lt KEY gt 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 lt KEY gt lt MAC gt ffffffffffffffff lt MAC gt lt KEY gt 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 lt KEY gt lt MAC gt ffffffffffffffff lt MAC gt lt KEY gt 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 lt KEY gt lt MAC gt ffffffffffffffff lt MAC gt lt KEY gt 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 lt KEY gt lt ApsTable gt The EMU will then find the dongle and join to it and you should see the three stages of the key exchange Information Text KEC Status lt Text gt lt Type gt 1 lt Type gt lt Cmdld gt 0 lt Cmdld gt lt Status gt 0 lt Status gt lt Information gt Information Text KEC Status lt Text gt lt Type gt 1 lt Type gt lt Cmdld gt 1 lt Cmdld gt lt Status gt 0 lt Status gt lt Information gt Information Text KEC Status lt Text gt lt Type gt 1 lt Type gt lt Cmdld gt 2 lt Cmdld gt lt Status gt 0 lt Status gt lt Information gt It is important that you see Cmdld 0 1 2 At this point the EMU is joined to the dongle www rainforestautomation com 21 22 rainforest EMU automation Technical Manual 6 Update the EMU Put the EMU into Diagnostic Mode again and go to the Firmware Update screen Press the Top Button to start the update and you should see Firmware Update Updating Progress 5
10. Channel gt 16 lt Channel gt lt Panld gt 0x7131 lt Panld gt lt Information gt 5 Join the EMU to the Dongle Put the EMU into Diagnostic Mode as described in the Diagnostic Mode section of this manual Go to the Link Key screen and record the two rows of numbers you see there Proceed to the Hard Reset screen and reset the EMU as described in the Hard Reset section of this manual After the EMU has reset it will begin to beacon and you will periodically see this type of announcement in the terminal window Information Text New node joined lt Text gt lt NwkAddr gt 0x000059bd lt NwkAddr gt lt Macld gt lt Macld gt lt Information gt Type the following text into a text editor and copy and paste it into the terminal window Command lt Name gt add_device lt Name gt lt Macld gt 0x lt Macld gt lt LinkKeyHi gt 0x lt LinkKeyHi gt lt LinkKeyLo gt 0x lt LinkKeyLo gt lt Command gt Where is the 16 digit MAC Address shown on the label of the EMU and is the 16 digits shown in the upper row of the Link Key screen and is the 16 digits shown in the lower row of the Link Key screen This will add the EMU to the dongle and you should see this response in the terminal window www rainforestautomation com rainforest EMU automation Technical Manual lt Aps Table lt MAC gt 1234567890abcdef lt MAC gt lt KEY gt fe dc ba 09 87 65 43 21 ab cd ef 01 2
11. al This manual provides information about Diagnostic Mode which is not intended to be used by non technical users www rainforestautomation com rainforest EMU o mat i Technical Manual Supported Clusters oro le se a Server 0x0000 Mandatory Commands Ir Identify 0x0003 Server Mandatory Commands EE 0x0000 Time Ox000a Client Read Attributes 0x00 TimeStatus 0x0001 LocalTime 0x0007 Key Client Establishment as engl CHEN Mandatory Commands 4 GetProfile s l Endrtim A4 D O Status D o y B oS 0x00 ProfileIntervalPeriod SS NumberOfPeriodsDelivered Po Intervals Ce 0x0702 Client Reading CurrentSummationDelivered 0x00 Infomation 0x00 CurrentSummationReceived 0x01 Gg Block Price Simple Metering ded Read Attributes 0x00 dud d dus Consumption Sol E ETS Price Trailing Digit and Tier Cd Start Time 1 1 1 y O Duration le T Price 0 0 0 0 0 0 0 0 0 O e 0x00 Curemcy Number Of Price Tiers amp Register Tier Ratelabe 1 1 1 Number Of Block Thresholds Block Price Eeer Price 0x0700 Client E ages StartOfBlockPeriod BlockPeriodDuration minutes GE ThresholdMultiplier Block Price Weg Commodity 0x03 Standing Charge L Dal e peemedmeu H Jess Information ox00 O u M M C mor L E received MessageContr
12. device will be decommissioned and will not be able to immediately rejoin the smart meter The smart meter will not allow the EMU to join until the meter has also decommissioned the EMU and then reregistered EMU for joining A Hard Reset can be initiated from the Hard Reset screen in Diagnostic Mode see the previous section Selecting Reset Top Button in the Hard Reset screen brings up the following screen that confirms that you intend to perform a Hard Reset and disconnect from the meter Are you sure Disconnect from meter Cancel Pressing Cancel Bottom Button will abort the process and send you to Active Mode Pressing the Top Button will erase all existing data and configurations disconnect from the meter and reset the EMU If for some reason the EMU is unresponsive and it is not possible to get to the Hard Reset screen then this alternative procedure can be used a Open the battery cover Remove all of the batteries c Wait 10 seconds Press and hold down the Top Button While holding down the Top Button replace the batteries and cover f Once the display comes on release the Top Button this will be almost immediately after replacing the batteries o The EMU will have performed a Hard Reset and will be disconnected from the meter www rainforestautomation com rainforest EMU automation Technical Manual Firmware Update A Firmware Update will replace all of the application c
13. e pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Compliance Regulations For Australia and New Zealand This equipment complies with the C Tick labeling requirements for Australia and in New Zealand As a radio transmitter this device complies with the requirements of AS NZS 4268 2008 as designated in the Radiocommunications Short Range Devices Standard 2004 for Australia and as required by the Radiocommunications Regulations General Users Radio License for Short Range Devices Notice 201 1 for New Zealand This device is a Category A d
14. ens that are displayed during the procedure www rainforestautomation com rainforest EMU automatio Technical Manual For each Channel 11 up to 26 Send Beacon Request Heceive Beacons make list of Candidates For each Candidate mom Jr Searching for meters Connecting to Meter Please Wait Key Exchange Get Meter Data a Exit Next Candidate NN Next Channel E M Start Again The Joining Procedure is repeated continuously cycling through all the channels 11 26 looking for candidates to join If it has not joined after 6 minutes the device will enter Sleep Mode and the screen will go blank While in Sleep Mode the device will initiate one scan of all the channels every 60 seconds If a successful join occurs while in Sleep Mode the device will enter Active Mode If one of the buttons is pressed during Sleep Mode the device will enter Active Mode and will again loop continuously through all the channels looking for a candidate to join If it has not joined after 4 minutes the device will return to Sleep Mode It is important that the device not be restarted by removing and re inserting the batteries as described in the Troubleshooting Guide section of the EMU User Manual during the Joining Procedure This has unpredictable results and may cause the device to be decommissioned as if it had a Hard Reset www rainforestautomation com rainforest EMU
15. evice as defined in the Radiocommunications Compliance Labeling Electromagnetic Radiation Notice 2003 www rainforestautomation com rainforest EMU automation Technical Manual About This Manual This manual is intended for those needing detailed technical information about the EMU product such as customer support engineers and laboratory and field engineers performing evaluations and trials involving the EMU This manual is a companion to the EMU User Manual and both documents should be consulted None of the information contained in this manual should be required by the average consumer to operate the EMU product under normal conditions www rainforestautomation com rainforest EMU automation Technical Manual About the EMU The EMU is a ZigBee endpoint that acts as an In Home Display It implements the ZigBee Smart Energy Profile 1 1 The supported clusters are shown on the next page The EMU is battery operated and conserves power by going into Sleep Mode after four minutes of inactivity In Sleep Mode the display screen will be blank but the Indicator LED Lights will continue to flash as documented in the Price Tier Indication section of this manual The EMU also pings the smart meter once a minute while it is in Sleep Mode to ensure that meter is aware that the EMU is still in the network The Active Mode and Configuration Mode screens are described in detail in the EMU User Manu
16. field below RESET Dongle C Use next available MAC address from MAC address list file C Type new MAC address in MAC Address field below MAC Address List File FO Program FEEEEEEEE r About www rainforestautomation com rainforest o m a t i 2 Connect the Dongle Plug the dongle into an available USB port on the PC Open the Windows Device Manager found in the Look for a USB Serial Port under Ports COM amp LPT to find out which COM port has been assigned to the dongle Control Panel COM or COM2 3 Load Firmware Image onto the Dongle It should not be EMU Technical Manual Up med epee Fl Mice and other pointing devices AE Modems Ma Monitors D Work adapte J d Ports is COM iain USB Serial Port COM GL EL b Sil video and game controllers SR ba System devices Perform the following steps in the Flash Programming Software FlashGUl exe a e Configuration Program C FW_1 2 9 Relocate inhouse Client 14 Server 14 bin COM Port COMS Refresh Target DetectFiash BaudRate 1115200 v Sector 3 Save Programming Erase Le E a oe a Lesch Use MAC address embedded in application binary B Reuse existing MAC address in target device shown in MAC Adivess field below Use next available MAC address from MAC address list file Type new MAC address in MAC Address field below iS MAC Address List
17. he reset may be delayed if the update has been programmed by the utility to activate at a future time Manual Update Procedure The EMU can also be updated using a USB Programming Dongle The dongle emulates a meter and acts as an update server The dongle is available as a separate product RFA Z106 HP from Rainforest Automation The procedure below assumes that the dongle is being used with a PC running Windows XP or newer 1 Get Flash Programming Software Go to this link http Avww jennic com support software jn sw 4007 flash programmer Click on the download icon in the lower left corner of the web page and save the ZIP file Extract the files You will have a folder named JN SW 4007 Flash Programmer version where version is the current revision number Open the folder Open Tools Open flashprogrammer Double click FlashGUl exe You should see a screen like this Jennic JN51xx Flash Programmer 1 7 2 oj xi Configuration Prora oo oo o s s wj Browse Clear History COMPort coms Refresh Connect E Skip Verification T Target DetectFiash BaudRate 15200 sl TS meme Sector 3 Save Programming Erase v OO rz meme Device Control Device JN5148 001 Flash ST M25P40 USB Dongle only Choose how you want to assign the MAC address Automatic Program and Reset Iv Use MAC address embedded in application binary Reuse existing MAC address in target device shown in MAC Address
18. ly written to flash CR C Rainforest RFA Z105 LN EMUCurrentReleaseAFW 01 02 O9 emu rfaX0xFFFFFFFFFFFFFFFFLL PC gocce 1 29 App PC inhouse Clientl4 Serverl5 bin The dongle is now loaded with the firmware image 18 www rainforestautomation com rainforest EMU automation Technical Manual 4 Connect a Terminal Emulator to the Dongle The following steps describe how to use PuTTY a free terminal emulator but any simple terminal emulator can be used i amp PuTTY Configuration E x Go to this link http www putty org Download putty exe and run the file a Select Serial for the Connection type b Click on the Serial Category You should see the Options for controlling local serial lines see below Appearance Behaviour Ensure that Serial line to connect to is set to the correct COM port for the dongle and the Speed baud is set to 115200 Click on Open www rainforestautomation com 19 20 rainforest EMU automation Technical Manual You should see a black PuTTY terminal window with a curser Copy this text into the terminal window to paste into PuTTY click the right mouse button Command lt Name gt factory_reset lt Name gt lt Command gt This should reset the dongle and you will see text similar to this appear in the terminal window lt Information gt lt Text gt Network started lt Text gt lt
19. ode contained in the program memory of the EMU Once the process is started it cannot be stopped therefore it is important that the charge level of the batteries is enough to complete the process If there is any doubt you should replace the batteries first The Firmware Update process is initiated by selecting Update Top Button in the Firmware Update screen in Diagnostic Mode see the Diagnostic Mode Screens section If the meter the EMU is joined to does not support firmware upgrades you will see this screen Firmware Update Server Not Found lf the meter does support over the air upgrades but there is no firmware image to upload at this time you will see Firmware Update No Update Available Otherwise the upload process will begin and you will see Firmware Update Updating Progress 5 Once the update process has begun it must be allowed to complete uploading the new code in order for the EMU to function correctly Do not attempt to reset the EMU during a Firmware Update www rainforestautomation com rainforest EMU automation Technical Manual The unit may reset itself during the upload procedure If this happens you can get back to the Firmware Update screen the same way as before and you should see that the update is progressing After about 20 minutes you should see the progress reach 100 At this point the unit will return to active mode and will reset to activate the update T
20. ol NEN ELLE LL LL Message 0x0703 Client MessageID o 1 O MessageConr 0x00 Statim o received Duration 1 1 O Message o 2 O Prepayment Payment Control Prepayment 0x0703 Client Attributes Information 0x00 Credit Remaining E Prepay Set Credit Status 0x03 Prepay Lony enabled for prepayment support Price Label only enabled if Price Labels are used instead of Rate Label Block Price only enabled for block pricing support www rainforestautomation com rainforest EMU autom ation Technical Manual Startup Procedure Once the EMU has successfully completed its initialization procedures the display will show the Startup screen Normally this is the Rainforest Automation logo rainforest om ation Then the Joining Procedure will begin The procedure is as follows Send Beacon Request and look for a device that has the on flag enabled in its beacon After joining the network wait for the Coordinator to send the network key encrypted with our link key derived from the install code Look for the Key Establishment Cluster using match descriptor Perform Key Exchange If successful look for the time cluster and the metering cluster If successful ask for time The time needs to be a valid value If successful ask for metering pricing and messaging The flowchart for this procedure is shown below along with the output scre
21. rainforest a ut om a ti EMU Energy Monitoring Unit Technical Manual Version 1 27 Sep 2012 rainforest EMU automation Technical Manual Copyright 2012 by RAINFOREST AUTOMATION INC RFA All rights reserved No part of this manual may be reproduced or transmitted in any from without the expressed written permission of RFA Under copyright law this manual or the software described within cannot be copied in whole or part without the written consent of the manufacturer except in the normal use of the software to make a backup copy The same proprietary and copyright notices must be affixed to any permitted copies as were affixed to the original This exception does not allow copies to be made for others whether or not sold but all of the material purchased with all backup copies can be sold given or loaned to another person Under the law copying includes translating into another language or format Rainforest Automation may have patents patent applications trademarks copyrights or other intellectual property rights covering subject matter in this document Except as expressly provided in any written license agreement from Rainforest Automation the furnishing of this document does not give you any license to these patents trademarks copyrights or other intellectual property Trademarks Third party brands and company names mentioned herein may be trademarks and or registered trademarks of their re
22. spective companies and are the sole property of their respective manufacturers Notice The author s assumes no responsibility for any errors or omissions that may appear in this document nor does it make a commitment to update the information contained herein www rainforestautomation com rainforest EMU automation Technical Manual EMU Energy Monitoring Unit RFA Z105 Version 1 27 Technical Manual Table of Contents Regulatory Ae te dun QUOI P ccc 4 ADO THIS MARU AN sm EE 5 POUT CAT t e 6 Supported Clusters nennen nennen nnnn nnn sna nnns nans na nnns 7 Startup Procedure M 8 BIrfeerirc de c 10 NAVIGATION Gel e Ve 11 EMU Diagnostic Mode Screens cccccceececceseeceeeceseeeeesseeeessaeeessaeeessaeeesaneeesaaes 12 pue pm 12 Bi d ROY NETT 12 Rauen e T 12 Hard Heset 12 Wl imeem cc 13 giro ROS OU V 14 istis E T 15 WEI UH Ga te POC e Pi TTE EEE 16 1 Get Flash Programming Software aaannnennnennnnennnnnnnnennonnnennrrnnnrnnnrnnne 16 2 COMMECT ING DONG ce 17 3 Load Firmware Image onto the Dongle n nnnannnennnnnnnnnnennnnnnnnnnnnnnennnenn
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 - 黒田精工 1ノ“ - 別府市医師会 RFScada 2DI-4DO User Manual Inline Warehouse CD110 Switch User Manual VR1® Row/Rear Delt Owner`s and Service Manual COMMERCIAL AIR CONDITIONER Service Manual μPAC-5001D-CAN1 User Manual μPAC-5001D-CAN2 Poêle à bois non‑catalytique / catalytique Defiant MANUAL DEL OPERADOR Copyright © All rights reserved.