Home
        USER MANUAL
         Contents
1. Mount the bracket in the wall in upright position above the water  container  which contains a solution of pH reducing acid and  water     Place the pump in vertical position  with the tubes below  on the  wall  above and centered with the    Mounting bracket   Then go  down the pump until it is joined with the bracket  uae WENGE          Connect the pump to the MC122 pH controller  on the black and  white outlet   The pump will discharge 0 08 cL every 2 seconds     Place the plug and B W outlet far away from water     Before servicing  maintenance  on the pump  e g  changing  tube   please disconnect the equipment        It is suggested to dissolve 10 cL of pH reducing acid in a 5L container of mineral water   Depending on the volume of your tank and the brand of you pH reducing acid  if it is  more or less concentrated   this quantity will be balanced  It is better to dissolve more  than less  It is suggested to use an airstone on the bottom of your tank  The pump can  be attached directly to the container of the solution     OPTIONAL ACCESSORIES    M10004B pH 4 01 buffer solution  20 ml sachet  25 pcs   M10007B pH 7 01 buffer solution  20 ml sachet  25 pcs   M10010B pH 10 01 buffer solution  20 ml sachet  25 pcs   M10000B Electrode rinse solution  20 ml sachet  25 pcs   MA9015 Electrode storage solution  20 ml sachet  25 pcs   WARRANTY     These instruments are warranted from all defects in materials and manufacturing for a period of two years  from the date of purchase  T
2. ection base  black and white outlet  to the  main line     Connect the pH electrode to the BNC socket on the bottom of  the meter    Always remove the electrode protective cap before taking any  measurement  Make sure that the meter has been calibrated  before taking any measurements    Immerse the tip  2 5 cm  of the pH electrode into the sample    for example it can float with the help of a piece of polystyrol      Turn the instrument on by pressing the ON OFF button    The nature of the setpoint can be selected by setting the switch  to the desired position  ABOVE or BELOW     Allow the reading to stabilize and the meter will start continuous  monitoring     A blinking alarm will indicate when the measured pH value is  higher or lower than selected setpoint  depending on user  selection  When the alarm is activated  it also activates the  connection base and the auxiliary equipment    The setpoint can be selected by adjusting the central front knob  to the desired value  The selectable range is from 5 5 to 9 5 pH              ACTIVATED    1    as                  CALIBRATION     Remove the protective cap from the electrode    Immerse the electrode tip into a new sachet of pH 7 calibration  solution and allow the reading to stabilize    Adjust the pH7 calibration trimmer  on the front  to display    7 0  pH       Rinse the electrode with tap water and dry it with paper tissue   Open a new sachet of pH 4 calibration solution  immerse the  electrode tip into the sachet and al
3. he electrode is warranted for a period of 6 months    If during this period  the repair or replacement of parts is required  where the damage is not due to negli   gence or erroneous operation by the user  please return the parts to either dealer or our office and the repair  will be effected free of charge     Note  We reserve the right to modify the design  construction and appearance of our products without ad     Ae Milwaukee    www milwaukeeinst com    MC122 pH Meter       MAS Milwaukee _    USER MANUAL  MC720    MILWAUKEE MC122 PH CONTROLLER    WITH MP810 1 5 L H DOSING PUMP    M    CONTROLLER ON WHEN  65 75 85 HOWE  5      SO    SPECIFICATIONS    Range  Resolution  Accuracy  Setpoint  Alarm   Output  Power Socket    Power drivers    pH electrode  Environment    Power supply  Dimensions  Weight    MC122 pH Meter    0 0 to 14 0 pH   0 1 pH    0 2 pH   25  C    5 5 to 9 5 pH   active when measure is  higher lower than selected  setpoint depending on  user selection   115VAC  2A  60Hz   or 230VAC  1A  50Hz  MA911B 2  included    0 to 50  C  95  RH   not condensing   12 VDC  included   148 5 x 82 5 x 32 mm  180 g       MP810 Peristaltic Dosing Pump    e Constant Dosing flow of 1 5 I h   25 cc min    e No regulation   e Maximum pressure  1 bar   e Made of Polipropilene  PP    e Peristaltic tube in Santoprene   e Power supply  230 VAC   10     INSTALLATION OF CONTROLLER     Connect the supplied 240VAC 12VDC power adapter to the  meter and to the main line     Connect the conn
4. low the reading to stabilize   Adjust the pH4 10 calibration trimmer  on the front  to display     4 0 pH        The calibration is now complete and the meter is ready to take  measurements     It is suggested to recalibrate the meter at least once a month   after a prolonged stocking time and after pH electrode  replacement     INSTALLATION OF THE  MP810 1 5 L H DOSING PUMP       Connect the rigid tube to the pump  aspiration     arrow upwards    Fix the white filter on the other end of the tube  where the dis   solved pH reducing acid will be drawn in     to prevent small ob   jects entering the pump     Connect the soft tube to the pump  impulsion     arrow down   wards   The injection fitting will be placed at the end of this tube  only to inject into a piping   This fitting has a thread that links it  to the piping      FILTER       PIPING          
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
測距式クレーン接近検出装置 TCR−30L3 取扱説明書 機器事業部  UDO Media    取扱説明書 [PDF形式]    Copyright © All rights reserved. 
   Failed to retrieve file