1. Icon Action nm RSC E BC WEEN s e d Cardiac Thorax Ratio User Manual QuantorVet Plus TM 722 EN S Distance Measures distance Click the start and end point of the measurement A straight line is displayed between the two points and the measurement value is displayed at the end of the Straight line You can move the measuring line by dragging it You can move either one of the two control points by dragging them with your mouse You can also move the position of the measurement values by dragging it with your MOUSE Angle Measures angle Click on the center point of the angle you wish to measure and then click on two control points You can move both lines at once by dragging You can also move either one of the two control points You can also move the position of the measurement values by dragging them with your mouse 3 Rectangle Draws a rectangle Click the mouse at the desired position of the upper left corner of the rectangle and then drag the mouse to the desired position of the lower right corner of the rectangle and release the mouse button Click on an area within the rectangle to move it Drag the control points to resize the rectangle GO Ellipse Draws an ellipse Click the mouse at the desired position where the top and left most point of the ellipse would intersect drag the mouse toward the bottom right and release the mouse after reaching a desired size a
2. the ROI are used 201200243 2011 07 05 Lateral Figure 5 2 ROI Cropped Image To bring up the ROI Box again double click on the image or click on the ROI button When you click on the ROI button the film sizes listed below will be displayed on the screen When you select one of the given sizes the ROI Box will be adjusted to that size 8x10 10x12 14x14 14x 17 10 x 8 12 x 10 17 x 14 5 3 Marking The Marking feature is used to add markings on the image Markings can be added to the image by selecting a predefined marking or manually typing in text User Manual QuantorVet Plus TM 722 EN S Add Predefined Markings Click on the Marking button Select a marking 3 Click on the image Predefined markings can be edited in Settings under Overlay Marking Figure 5 3 Add Predefined Markings Manually Enter Markings Click on the Marking button Select Direct Input 3 Click on the position where you want to add the marking and a text input box will appear Enter your text Click outside the text input box when you are done Figure 5 4 Manually Enter Markings 5 4 Rotate Flip Used to rotate or flip images Icon Action User Manual QuantorVet Plus TM 722 EN S 5 5 Auto Window Automatically adjust the image brightness and contrast 5 6 Repeat Used when the quality of the scanned image is insufficient and requires a rescan Remember that the current image
3. SA QuantorVet User Manual veterinary Acquisition and diagnostic software Doc No TM 722 EN S Rev 1 0 1 Aug 2013 Part No CR FPM 04 022 EN S 3DISC FireCR Quantor and the 3D Cube are trademarks of 3D Imaging amp Simulations Corp South Korea and its affiliates All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications which must be met by 3D Imaging amp Simulations Corp All information contained herein is intended for guidance purposes only and characteristics of the products and services described in this publication can be changed at any time without notice Products and services may not be available in your local area Please contact your local sales representative for availability information 3D Imaging amp Simulations Corp strives to provide as accurate information as possible but shall not be responsible for any typographical error Copyright 2010 3D Imaging amp Simulations Corp all rights reserved printed and published in South Korea by 3D Imaging amp Simulations Corp IMAGING User Manual QuantorVet Plus TM 722 EN S Table of contents 1 System Requirements and Gtartup 4 be EVON OI EE 4 1 1 1 Recommended Computer Heourement 4 1 1 2 Minimum Computer Requirement cccccceccessseeeeeeeeeeee
4. aeeeeeeeeeeeessaaaaeeseeeees 4 12 DIA 010 Jen WAN PE N 5 kede OV SUSI BT GE 5 Tees EE OO E 5 1 2 3 Terminate Program 5 E CS 7 2 1 SGUDDOMECO FOSOIUN ONS sisrccicisnuacsesccsetsnnisamsinasienainemainmdsassmaiondiiemdsnnians 7 E ee 7 2 3 E NAVI AN OPS EE 8 EE 8 NON OU a eee eee ee eee tee 9 20 TCOMOM SClCCHON ESS ree 9 2 7 Patient Information 00 2 ccc cece eccecceeceeceeceeceeceeeeeceeeeeseeeseeeeeseeseeseeseeneesess 9 i Eer ea oe a a ne A E 10 P OVO cece eer eee nee es ee ee ee des Pe see eed one ac 10 3 New Ziudy 11 el OCTO EG OUR EEE E EE E EEAS 11 4 Region Selection 13 A 1 21 E e 13 OR E 14 5 1 OSEO 14 5 2 EE 15 33 WAV PRET cee TITI TT 15 E M TO AO EE 16 5 5 Auto Window nr nrrnrenrereceeeesees 17 5 6 EE 17 57 PO aa ae E ne de ado ae 17 5 8 DONC EE 18 ic M EXPOS S a a 18 O TIK EEN 19 User Manual QuantorVet Plus TM 722 EN S OR OCC era ce rec eee eer see ee ees 19 Be ICI E 20 Fe TAC VICW ea 22 Pels rc e 22 fie VW eet 23 TD FUO OO a ann ea ec ee ae eee 24 7 4 Image Manipulation 25 ko MoS OO 25 G i EE ere 28 Fol DONS nee ee ne 29 7 8 Apply Range rer 30 C DE e e E 31 User Manual QuantorVet Plus TM 722 EN S 1 System Requirements and Startup 1 1 Environment 1 1 1 Recommended Computer Requirement Operating System Microsoft Windows 7 8 niel CORE 8 RAM 4 GB or more Hard Disk 500 GB Free Hard Disk Space 1 Gbps Ethernet 32bit Color Dis
5. anual QuantorVet Plus TM 722 EN S 2 5 New Study The New Study screen is the first page for performing a scan After entering the necessary patient information and study information and adding a new study you can begin a scan Figure 2 4 New Study 2 6 Region Selection In the Region Selection screen you can select the region to scan and add it to the Task List Figure 2 5 Region Selection 2 Patient Information The Patient Information Bar is displayed at the top of all the screens with the exception of the Home screen and the New Study screen The Patient Information Bar displays patient information and other related information Figure 2 6 Patient Information Patient Name 2 Patient ID User Manual QuantorVet Plus TM 722 EN S 3 Patient s Date of Birth 4 Patient s Age Patient s Sex M Male F Female O Other SM Sterile Male SF Sterile Female S Sterile Current Time D Model Name System 2 8 Scan In the Scan screen you can insert a cassette into the FireCR and acquire images Figure 2 7 Scan Screen 2 9 Review In the Review screen you can query scanned images in the identical manner as the PACS Viewer The Review screen is very useful for conducting diagnosis after acquiring the images Figure 2 8 Review Screen User Manual QuantorVet Plus TM 722 EN S 3 New Study 3 1 Screen Layout The New Study screen is the first pa
6. e Max Maximum value Mean Average value a oe oe ge eS TS Current Value Pixel value of the current position when the mouse was clicked over the graph Marking Icon Action Mm 7 6 File Open DICOM File Open Image File User Manual QuantorVet Plus TM 722 EN S 7 Tools Icon Action nm Copy to clipboard Copies the active image to the Windows clipboard Ip Sets pixel size Scan a measuring tool with a determined length Select the scanned image and click on the Pixel Calibration button The following dialog box will be displayed on the screen Enter the actual length of the measuring tool Click on the start point of the measuring tool over the image and start dragging Release the mouse at the end point of the measuring tool to complete the calibration User Manual QuantorVet Plus TM 722 EN S 7 8 Apply Range Sets the range in which image processing will be applied When comparing two images you can apply the same filters to both windows for easier comparison Select You can select multiple images by clicking on images while holding down the Ctrl key The selected images are marked by a blue border Image filters that can be used with Apply Range are as follows Zoom Pan Rotate Flip Window User Manual QuantorVet Plus TM 722 EN S 7 9 Export 2012 06 19 15 49 35 Sample A ID000002 M 4 4 Sampl E CDDVDW SN 208BB CO 4 4 ample S
7. elect All Unselect All 89 0 0 0MB 0 00 SA Anonymize Figure 7 2 Export Device Select the storage device to export the images to Optical disc drives connected to the PC will be listed If you select Local you can use other storage devices connected to the PC Label Label to be displayed on disc Media Type Displays the type of the media inserted in the drive GO Local Folder Activated only when Local is selected in the Device field Select a destination folder to save images Format Select format to save images Supported formats are as follows A DICOM B Bitmap Windows Bitmap file C Raw RAW file D Jpg JPEG E Tiff TIFF Log Message Shows the progress when recording to an optical disc D Progress Bar Shows the image export progress Study List Shows the list of selected studies Image List Shows images selected in the Study List To not export a certain image User Manual QuantorVet Plus TM 722 EN S click and unselect the image Select All Select all images Unselect All Unselect all images Anonymize Delete patient name and ID when saving as DICOM images Close Close the dialog box Abort Stop recording Burn Start recording
8. elected image clockwise Rotate Angle The angle to rotate the image Reset Reset images Cancel Return to the previous screen Stitch Stitch images and return to the previous screen User Manual QuantorVet Plus TM 722 EN S Review 7 1 Screen Layout The View offers the identical functions as a PACS Viewer It supports various image comparison processing and measurement tools for performing a diagnosis The screen displaying the image consists of multiple views Each view consists of multiple images The user can customize the view layout and image layout according to their needs Figure 7 1 View Image Layout To display an image in the view all you have to do is simply drag the image from the Task Bar When an image is dragged from the Task Bar only the image is displayed in the view When a Study Bar is dragged all the images included the study are displayed in the view User Manual QuantorVet Plus TM 722 EN S Q 201200243 2011 07 05 2012 07 05 10 57 32 D 952 x 1312 C 2048 W 4095 4 2012 07 05 11 27 59 100mm Ka 1500 x 1204 1848 x 1172 C 2048 W 4095 C 2048 W 4095 Figure 7 2 Review Screen View Caption Bar The caption bar of the view Full Screen Show the review screen in full screen mode View Window Layout Change the layout of the view Zoom Used to zoom in and out of the i
9. ge when performing a scan Enter the necessary patient and study information You can easily switch to the next input field by using the Tab key Fields marked by are mandatory DICOM fields that must be filled in Ref Physician Accession No On Screen Keyboard PgUp PgDn Pause ScrLk Help Figure 3 1 New Study Emergency Mandatory fields are filled in automatically This function is used in emergencies where patient information has not been identified to perform a scan first and fill in the patient data later Edit Input Field Bring up Input Field Edit dialog In the Input Field Edit dialog you can change the order of the input fields and add or remove input fields System Menu Display the System menu Input Field Details about each input field are described in Table 3 1 User Manual QuantorVet Plus TM 722 EN S Table 3 1 Input Field ry Enter patient name Do Enter patient ID Enter patient s date of birth You can select a date from the drop down box or manually enter numbers When only the date of birth is entered and not the age age is calculated automatically Select patient s sex Male Female NA Sterile Male Sterile Female Sterile Enter patients age Leave the Year field blank if the patient is A less than 1 year old When only the age is entered and not the ge SE date of birth date of birth is calculated automatically When it does month and date are automatical
10. hing pages 6 2 Stitch The Stitch function is optional A Stitch Dongle is required to use the Stitch function When stitching begins a screen shown in Figure 6 2 will be displayed on the screen and the selected images will be displayed vertically according to the order in the Task Bar When you adjust the position and angle of the images and begin stitching the two images will be stitched into one and added to the Task List 201200303 2005 05 05 Quantor O Go oO B E E Figure 6 2 Stitch User Manual QuantorVet Plus TM 722 EN S Q Zoom Used to zoom in and out of the image Drag the mouse over the image to control the zoom It does not zoom in out on a single image and zooms in out on the entire screen Pan Pan the image Drag the mouse over the image to control the zoom The selected image pans separately Fit to Page Size Adjust zoom to fit the image to the height of the screen Fit to Page Width Adjust zoom to fit the width of the screen Clip Show hide clip adjustment line in the image Clip lines are displayed as dotted lines Drag the dotted line using the mouse to clip the desired region Show Guide Line Show hide horizontal dotted line to check horizontal level of the scanned image The position of the guide line can be adjusted by dragging it using the mouse Rotate Left Rotate the selected image counter clockwise Rotate Right Rotate the s
11. ly entered as January 1 Ref Physician Enter the name of the referring physician Enter study description Enter accession number Entering an accession number is Accession No mandatory If not entered a new number will be generated automatically Enter patient length Select patient species Dog Cat Rabbit Small Rodent Bird Species Exotics Horse Cow Enter patient breed Enter patient owner Page Up Down Go to another page Next Go to the Region Selection screen which is the next step User Manual QuantorVet Plus TM 722 EN S 4 Region Selection 4 1 Screen Layout In the Region Selection screen you can select the region to scan and add it to the Task List S Skull Lateral Pelvis AP Figure 4 1 Region Selection Body Part The region to be scanned will be displayed on the figure of the animal body When you move the mouse cursor over the figure the region to be selected will be marked by a different color Select the desired region and the View Position List will be updated View Position Displays view positions that correspond with the selected region for scanning Click on the region to scan and the region will be added to the Task List Preset Displays view position presets When a certain setting is used frequently you can easily automatically add multiple view positions by selecting a preset instead of adding separate view positions each time Page Up Down But
12. mage Drag the image left right up or down using the mouse Pan Pan the image Drag the image left right up or down using the mouse Image Manipulation Open image manipulation tools for rotating flipping and inverting images Measurement Provides various measurement tools for measuring distance and angle Marking Provides marking tools File Display DICOM file on the screen Tools Provides other tools Apply Designate the range in which image adjustments will apply View Caption Bar Figure 7 3 View Caption Bar User Manual QuantorVet Plus TM 722 EN S Image Layout Change image layout When you click on the Image Layout button a 3x3 grid shown in Figure 7 4 will appear on the screen Select your desired layout The largest image layout available 3x3 Figure 7 4 Image Layout Page Up Go back to the previous page 3 Page Down Go to the next page 4 Close Close all images 7 3 Full Screen Expands the Review screen to full screen mode as shown in Figure 7 5 201200243 2011 07 05 1 V Quantor 1 2012 07 05 2012 07 05 11 12 12 10 57 32 D fi 50mm d KM kl 952 x 1312 2 8 W 4095 AIS 4 2012 07 05 11 27 59 Hi K 100mm o offs ooo ong 100mm 1500 x 1204 i E 1848 x 1172 C 2048 W 4095 a C 2048 W 4095 Figure 7 5 Full Screen User Manual QuantorVet Plus TM 722 EN S 7 4 Image Manipulation Icon Action 7 5 Measurement
13. nd shape Click on an area within the ellipse to move it Drag the control points to resize the ellipse User Manual QuantorVet Plus TM 722 EN S Draws a polygon A control point is added every time you click the mouse Double click when you are done drawing the polygon Click on an area within the polygon to move it Drag the control points to change the corners of the polygon Creates a free draw selection Click and drag the mouse to the desired shape Release the mouse when you are done drawing You can click inside the selection to move the free draw selection Measures pixel value Click and drag the mouse and the coordinates x y and pixel values p of the pixel at the cursor position will be displayed on the screen Measures cardiac thorax ratio 1 Click on the left end point of the thorax 2 Click on the right end point of the thorax 3 Move the upper left control point to the left end point of the heart 4 Move the upper right control point to the right end point of the heart 5 The measurement value will be displayed in percent Profile Draw a straight line in the same manner as measuring a distance and a profile dialog box will be displayed automatically User Manual QuantorVet Plus TM 722 EN S Start Point Max Value 1 Distance Distance between two points Start Point Start point information End Point End point information Min Minimum valu
14. nded resolutions are listed in Table 2 1 Table 2 1 Screen Ratio Screen Resolution 1366 x 768 1280 x 800 1400 x 900 1600 x 900 1920 x 1080 4 3 5 4 1280 x 1024 2 2 Home The Home screen is the first screen that appears when the program is run From the Home screen you can create a new study or view existing studies Figure 2 1 Home Screen User Manual QuantorVet Plus TM 722 EN S 2 3 Navigation Bar The Navigation Bar is located at the bottom of the screen The Navigation Bar is always displayed while the program is running allowing the user to easily switch screens during a task Figure 2 2 Navigation Bar Home Studies Region Selection Scan D OG Review 2 4 Studies The Studies screen shows a collection of windows that are related to the studies You can enter the Studies screen by clicking the Studies button in the Navigation Bar The Sub Navigation Bar is located on the left of the screen In the Sub Navigation Bar you can select a Study List Work List or Transport windows that are related to the study Figure 2 3 Studies Screen Study List You can perform various tasks by searching existing studies and selecting a study Work List You can query the work list from the PACS work list server select the desired study and immediately begin image acquisition Transport You can confirm the transmission results of the acquired images User M
15. pley Video Resolution 1920 x 1080 1440 x 900 1 1 2 Minimum Computer Requirement Operating System Microsoft Windows XP intel Processor RAM 2 GB or more Hard Disk 80 GB Free Hard Disk Space 1 Gbps Ethernet 32 bit Color Display Video Resolution 1366 x 768 1280 x 800 1600 x 900 1280 x 1024 User Manual QuantorVet Plus TM 722 EN S 1 2 Start and Termination 1 2 1 System Start 1 Turn on the FireCR CR Reader 2 Turn on the monitor and PC WARNING Do not run any application software other than QuantorVet during operation of the scanner This may slow the scanner response 1 2 2 Start Program After Windows is successfully booted you can launch the QuantorVet program by double clicking the QuantorVet icon on your desktop as shown in Figure 1 1 QuantorVet Figure 1 1 Short Cut Icon 1 2 3 Terminate Program Select the System button as shown in Figure 1 2 on the Home Window Figure 1 2 System Button Now you can exit the application by selecting Exit in the System Menu User Manual QuantorVet Plus TM 722 EN S Figure 1 3 System Menu User Manual QuantorVet Plus TM 722 EN S 2 Screens 2 1 Supported Resolutions Landscape resolutions with 16 9 4 3 and 5 4 ratios are supported Portrait ratios are not supported The horizontal resolution of the monitor must be at least 1280 pixels and the vertical resolution of the monitor must be at least 768 pixels Recomme
16. sts of a list of tasks The check boxes located to the right of the task bar is used to select tasks 201200243 2011 07 05 ull Lateral Figure 6 1 Task List Study Bar Displays study date study time and study description Only time is displayed for studies conducted on the same day Only dates are displayed for studies conducted on any prior dates Task Bar Displays thumbnail images body part and view position Select all Select all the tasks 4 Add Preset Add the selected study to the preset When added to the preset the added study will be displayed on the Preset List in the Region Selection screen Delete Delete selected tasks Edit Show hide Move and Switch buttons Send Study Transmit the selected study Destination of the transmission can be added User Manual QuantorVet Plus TM 722 EN S in Settings Print Print the selected images using a DICOM printer or a Windows printer Stitch Used to stitch multiple images into one when long bones are scanned To stitch images all the images must have the identical scan resolution Images scanned in SD resolution and in HD resolution cannot be stitched Up to three images can be stitched into one Move Change the order of the tasks Change the order of the task by pressing the Up Down buttons OD Switch Switch the images of two tasks The button is only activated when two tasks are selected OO Page Up Down Button for switc
17. ton for switching pages Task List List of view positions added from View Position or Preset fields Previous Go back to New Study screen QQ Next Proceed to scan screen User Manual QuantorVet Plus TM 722 EN S 5 Image 5 1 Screen Layout When an IP scan has been completed the acquired image is displayed on the Scan window as shown in Figure 5 1 TASK LIST 2012 07 05 e e oe Q CRC Figure 5 1 Image ROI Box A tool for cropping the valid region of the scanned image ROI ROI related tools Marking Add markings on the image Rotate Flip Rotate flip the image Auto Window Automatically adjust the image brightness and contrast Repeat Scan the image again Reject Reject the image QA Bring up tools for adjusting image details Send Image Transmit the image Exposure Index Show the exposure index value of the scanned image User Manual QuantorVet Plus TM 722 EN S 5 2 ROI When a scan is completed the image is displayed and the ROI Box of the predefined size for each scanned region is automatically displayed as shown in Figure 8 1 When you drag the ROI Box to the desired location and double click the ROI Box or click on the ROI button the ROI is cropped and fitted to the screen as shown in Figure 8 2 To adjust the size of the ROI Box drag the small rectangles at each corner of the ROI When transmitting or printing the image only
18. will be deleted 5 7 Reject When the quality of the scanned image is insufficient Reject preserves the current image with a Reject marking without rescanning When the Reject button is clicked a Reject marking is added on the upper left corner of the image as shown below and a Reason input field appears on the screen Type in the reason for rejection and click outside the input box when you are done You can cancel a rejection by clicking the Reject button again Figure 5 5 Reject User Manual QuantorVet Plus TM 722 EN S 5 8 Send Image Immediately transmits current image to the image server designated in Settings If Network Export Options Show Destination is checked under Settings a dialog box for choosing the destination will be displayed as shown in Figure 5 6 and the user can designate a destination 192 168 1 101 SERVER2 192 168 1 102 Figure 5 6 Destination Select 5 9 Exposure Index The recommended EI value is between 1800 and 2200 1800 lt Dose lt 2200 Dose is optimal Dose lt 1800 Dose is too low Dose gt 2200 Dose is too high User Manual QuantorVet Plus TM 722 EN S 6 Task List 6 1 Screen Layout The Task List is a list of scans to be performed Tasks are group by studies and arranged in chronological order The user can select the desired region and perform a scan The Task List consists of a list of studies and each study consi

Download Pdf Manuals

image

Related Search

Related Contents

HP Color LaserJet CM2320 MFP Series Quick Reference Guide  取扱説明書 - 日立の家電品  EGP-230 電子銃制御装置ご使用上の注意に関して  Utilisation et fonctionnement  Lenovo IdeaTab A8-50 16GB Black, Blue  Mode d`emploi AED de formation  小規模事業場向け有機性排水処理技術 実証試験計画書  InstallatIon · Manual 4.0281 1/6  User`s Manual - ICP DAS USA`s I  TABLA DE CONTENIDO Notas sobre este manual  