Home

User Manual - INTEC Controls

image

Contents

1. Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 32 A RELEVANT SOLUTIONS COMPANY 9 Notes and General Information It is important to read this user manual carefully in order to understand the information and instructions The PolyGard SPC3 gas monitoring control and alarm system may only be used for applications in accordance to the intended use The appropriate operating and maintenance instructions and recommendations must be followed 9 1 Intended Product Application The PolyGard SPC3 is designed and manufactured for controlling for saving energy and keeping OSHA air quality in commercial buildings and manufacturing plants i e detection and automatic exhaust fan control for automotive maintenance facilities enclosed parking garages engine repair shops warehouses with forklifts fire stations tunnels etc 9 2 Installers Responsibilities It is the installer s responsibility to ensure that all PolyGard SPC3 are installed in compliance with all national and local regulations and OSHA requirements All installations shall be executed only by technicians familiar with proper installation techniques and with codes standards and proper safety procedures for control installations and the latest edition of the National Electrical Code ANSI NFPA70 It is also essential to follow strictly all instructions as provided in the user manual 9 3 Maintenance We recommended checking
2. MSR NEL CONTROLS A RELEVANT SOLUTIONS COMPANY PolyGard Single Point Controller SPC3 11XX Single Point Gas Controller Serial Number _E_ 1007 User Manual May 2009 June 05 2015 Revision Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX sueo UNEL CONTROLS A RELEVANT SOLUTIONS COMPANY T DESCHIPtOM omic A aia 4 2 Operating INStrUCtiON omiiia dni 5 2 1 Description Keypad User Interface ccccccececeececceceeeeeeeeeeceaeaeeeeeeesessecsaaaeceeeeesesecaaaaeaeeeeeeeseeancanaeeeeeess 5 2 2 Setting Changing Setups or Set Points cece eee eecee teeter eset eaaeeeeeeeaaeeeeeeaaeeeeeeaeeeeeeeaeeessiaeeeeeeeaas 5 Ps COde Levels A ete iheleetinatdahinachd E A A N a 6 3 Menu OvVervieW coccion cette ne cette entcebee a aa ea aAA KEAN aa ctbdce bre nttbdee setters nue PAWANA AUKEN NARAN st 6 3 1 Fault Management ovina o divided Sl ened ceed lee dd 7 3 1 1 Acknowledge a Faulticuionininaci nada a e a 7 3 1 2 Error Memory 222263 c2cscis cecdec ce Ladedecbi indies a needechbndadacdnludenceh sedcchtaudedvebladenced qdedechbanebnsedvetadudewesbantes 7 AS A A O R 8 ae lage Status 34a a a nie ea ens
3. Check cable to transmitter make calibration replace the transmitter GC Error Internal communication error I O Board to LCD Board Cause Internal error Solution Change the Gas Controller module Maintenance System maintenance is necessary Cause Maintenance date exceeded Solution Make the maintenance 3 2 Stage Status Display of the actual alarms in plain text in the order of their arrival Only those measuring points are displayed where at least one alarm is active Changes are not possible in this menu Symbol Description Function Measuring lle SP Point No A1 Alarm 1 ON A2 Alarm 2 ON AX Stage Status 13 Alarm 3 ON A4 Alarm 4 ON Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 09 A RELEVANT SOLUTIONS COMPANY 3 3 Relay Status The SPC3 has two alarm relays R01 R02 and two open collector outputs R03 R04 In the following description they are referred to as alarm relays Display of the actual status of alarm relays Manual operation of the alarm relays P Setting Symbol Description Status Function R01 Relay No 01 Select Relay No OF
4. Dimensions W x H x D 142 x 142 x 63 mm 5 59 5 59 x 2 48 in Weight Approx 0 6 Ibs 0 3 kg Protection NEMA 1 general purpose Installation Wall mounting 3 holes for 1 2 in conduit for wall surface Cable entry mounted and 1 hole on back side of base plate for single gang electrical box mounting Wire connection Screw type terminals min 0 25 to 2 5 mm 14 to 30 AWG Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 Fax 858 578 4633 amp 888 FX INTEC www inteccontrols com SPC3 11XX US Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 28 A RELEVANT SOLUTIONS COMPANY Approvals Listings CE Certification to UL 2075 amp UL 2017 Pending unit VDI 2053 C No 418791 EMV Compliance 89 336 EWG EMV Compliance 2004 108 EWG Low voltage directive 73 23 EWG sensor UL Recognized UL Recognized E41515 relays R1 R2 CSA C22 2 No 0 No 14 File No LR31928 UL Listed E208470 CSA Certified E208470 enclosure Options Analog input external transmitter 4 20 mA input resistance 200 Analog input 1 0 2 10V input resistance 25 kQ overload and short circuit proof Power supply for external analog transmitter 24 VDC VAC dep
5. Reset function of the relays See from point 3 3 Displays the Sensor Reading See point 3 4 Display and change of the relay setups See from point 3 5 Display and change of the sensor point setups Activate or Deactivate SP Assignment of the alarms to the alarm relay See from point 3 6 so 8 8 8 0 Display and change of the system setups See from point 3 7 Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 07 A RELEVANT SOLUTIONS COMPANY 3 1 Fault Management The integrated fault management records the last 15 faults with date and time stamps in the menu System Errors Additionally a record of the faults occurs in the Error Memory which can be selected and reset only by the service technician An actual fault is displayed in plain text in the starting menu The failure relay which is defined in the system setup Failure relay is activated The yellow LED in the front of the gas controller flashes In case of fault of a sensor point SP the alarms defined in the menu SP Setup is activated additionally 3 1 1 Acknowledge a Fault Attention Acknowledging a fault is only possi
6. Transmitter 6 Bus_A MP 02 n 5 0 2 10 V 0 2 10V 4 Analog_Out 24 VDC 3 24 VDC_Out 0 VDC 2 0 VDC 1 124 VDC Analog output X4 OV 24 VDC Analog Output Signal Selecttable via Jumper 0 4 20mA 0 2 10 V Digital X5 Input DIO 1H ext Buzzer R3 2 24V 3 V 4 K R4 5 Warning Flash light ov 16 NO1 g R1 7 NC_1 8 COM_1 9 COM_2 R2 912 10 NO NC_2 jo 9 11 R1 SPDT 30 VAC DC 0 5A R2 SPNO SPNC 30 VAC DC 0 5A R3 R4 Open Collector 30 VDC 50 mA The analog input function is determined by the hardware Each PCB has got a label with the specific type Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 SPC3 11XX US Specification subject to change without notice www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 24 A RELEVANT SOLUTIONS COMPANY 4 3 Connector Block Overview SPC3 Module aoao a ema A o ON Da F amp F WN N OO A 0A DN o Anal Output Fig 4 5 Commissioning 5 1 Commissioning Prior to commissioning the wiring of the SPC3 including all field devices must be completely terminated Check the optional external transmitter input signal it has to be the same as indicated on the label of the PCB See Fig 5 Select the contact for
7. CONTROLS PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 22 4 Mounting Electrical Connection The Gas Controller is fixed to the wall through the marked mounting holes at the back side of the housing These mounting holes are accessible after opening the housing For the mounting you have to plug off the PCB See fig 01 The mounting holes at the plastic housing are covered with the enclosed caps after the end of the assembly We recommend considering the following when choosing the mounting position Installation height approx 1 6 m Oo e Cables are introduced from below e Keep at least 150 mm of distance on the right side in order to open the stainless steel housing e Customer s instructions 5 12 in 130 mm 5 59 in 142 mm gt 2 75 in 70 mm E De Y pa Cable entry Elz EJE Els E E Slo pede Pie o xe ene i 0 g sls gt OLN iQ 10 lt p 4 O y Fig 01 Standard plastic housing Stainless steel housing 4 1 Electrical Connection The technical requirements and regulations for wiring electrical security as well as project specific and environmental conditions etc must be observed when mounting The electrical installation may only be completed by a qualified electrician in full compliance with pertinent regulations 1 The recommendation does not consider local conditions such as fire protection etc For the exact position of
8. relay 2 with jumper NC NO See fig 2 3 and 5 Select the analog output signal with jumper V A and 0 20 See Fig 5 After switching the power supply ON and at the end of the Power ON Time the SPC3 is ready for use The SPC3 is delivered with standard setups and set points The registration of the optional external gas transmitter and the assignment of the alarm relays to the individual alarms must always be performed during commissioning Additionally all other setups have to be checked and adapted to the local conditions The standard setups can be taken from the following configuration and setup card We recommend registering the individual setups and set points into the list We recommend checking the setups and set points according to the following check list Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 5 2 Checklist Commissioning Setup Finished Time and date Setup of average function Password level 1 customer s password Function analog output Define fault relay Power ON time Service phone no Maintenance date ET ST RelayR 1 2 3 4 Relay mode Fun
9. 20 ppm Y 120 ppm ppm Alarm Stage Set Point of average overlay 1800 s AV Time 1800 s sec Time for the calculation of the average value Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller NEC Page 20 User Manual SPC3 11XX A RELEVANT SOLUTIONS COMPANY 3 7 5 System Time System Date Time and date have no memory back up therefore after each power supply OFF ON time and date restart Input and correction of time and date Selection of the time and date format er Default Symbol Description Status Function EU Display of time and date in EU format 03 Time format Ee US Display of time and date in US format Beanies Time hh mm ss Input of the correct time EU format ke es hh mm ss am Input of the correct time US format MM DD YY Input of the correct date EU format MPEP Ee Date MM DD YY Input of the correct date US format 3 7 6 Customer Password Code 1 Change the system password for level 1 ee Default Symbol Description Status Function 1234 Customer 1234 1234 Define the customer s password with 4 characters Password 3 7 7 Analog Output The Single Point Gas Controlle
10. 300 TEM Temperature C 0 50 RH Humidity RH 0 100 CO Carbon dioxide ppm 0 5000 TOX Toxic gas ppm 0 XX 1 Recommendation without obligation Decreasing signal at oxygen measurement Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 SPC3 11XX US Fax 858 578 4633 amp 888 FX INTEC www inteccontrols com Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 16 A RELEVANT SOLUTIONS COMPANY 3 6 3 Measuring Range The measuring range can be defined arbitrarily between 0 and 10 000 The measuring ranges in the table gas type are only recommendations without obligation The measuring range for SP01 inside toxic sensor is factory set the measuring range for SP02 must agree with the signal 4 to 20 mA 0 2 to 10 V of the attached gas transmitter 4 mA 0 2 V Display O ppm 20 mA 10 V Display of the ultimate value of the measuring range 3 6 4 SP Signal Gas transmitters using electro chemical or catalytic beat gas sensors normally produce a linear 4 to 20 mA 0 2 to 10 V signal proportional to the gas concentration Semiconductor gas sensors produce a non linear exponential signal This signal leads to a non linear 4 to 20 mA 0 2 to 10 V signal of the gas transmitter The Sing
11. 34 30s o e E A A A AN NOA E O e da Calibration ene ee ia 6 2 Configuration Card of Alarm Relays Relay Mode Static Latching Horn No Flash Mode Function ON OFF ON OFF lp y Time Quiet Di f Di Di f Di Di Default Energized Os No o o o o o o _o R01 R02 R03 R04 6 3 Configuration Card of Measuring Setups SP No S fault active 01 02 Delay Time CV Assigned SP Assigned Alarm AO sec AV Fault lt gt Alarm lt gt Alarm Rela Orr __ At a4 a1 a2 as As ON ERES AECE Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 7 Specifications SPC3 own UNEL CONTROLS A RELEVANT SOLUTIONS COMPANY Electrical Power supply 18 28 VDC AC reverse polarity protected Power consumption without options 100 mA max 2 5 VA Power Consumption with 1 remote sensor connected 200mA 5 VA Analog output signal Selectable Current Voltage Starting point O or 20 0 4 20 mA load lt 500 Q 0 2 10 V load gt 50 kQ Proportional overload and short circuit pr
12. 8 GO INTEC See 3 7 1 See 3 7 2 See 3 7 3 See 3 7 3 See 3 7 4 See 3 7 4 See 3 7 3 See 3 7 6 See 3 7 8 See 3 7 9 d O INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 See 3 7 7 See 3 7 7 Fax 858 578 4633 8 888 FX INTEC www inteccontrols com sueo UNEL CONTROLS A RELEVANT SOLUTIONS COMPANY SPC3 11XX US Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 3 7 1 Service Mode ae UNEL CONTROLS A RELEVANT SOLUTIONS COMPANY When the service mode is active ON the alarms are not transmitted to the alarm relays in case of calibration or service work The service mode is reset automatically after 60 minutes or manually in the menu Service Mode Aner Default Symbol Description Status Function Off Service Mode Off Off E Alarms activate the associated alarm relays On Alarms are not transmitted to the alarm relays 3 7 2 Software Version A Default Symbol Description Status Function GC03 Software sel y XX Versio XX Software Version 3 7 3 Maintenance Concept Integrated in the SPC 03 system there is a control of the maintenance intervals required by law or by the customer At commissioning or after maintenance the number of days until the next due maintenance is entered Reset of the maintenance message service phone no When the days counter re
13. Alarm ON at SP failure 3 6 9 Alarm Assigned to Alarm Relay Each of the 4 alarms can be assigned to any alarm relay Unused alarms are not assigned to any alarm relay nee Default Symbol Description Status Function SP 01 Measuring Point Selection of SP No A1 01 01 Alarm 1 activates alarm relay R 01 1 A2 02 02 Alarm 2 activates alarm relay R 02 A3 03 03 Alarm 3 activates alarm relay R 03 A4 04 00 Alarm 4 doesn t activate any alarm relay 3 6 10 SP Signal Assigned to Analog Output The sensor point signal can be assigned to the analog output At this the signal defined in the control mode current or average value is transmitted Analog output see also 3 7 7 Symbol Description ca Function SP 01 Measuring Point Selection of SP No 0 A 0 0 SP Signal not assigned to analog output 1 SP Signal assigned to analog output 1 Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 3 7 Menu System Setups Displays and changes the system setups of the Gas Controller module m Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 88
14. Definition of the failure relay See also fault management 3 1 Symbol Description SE Function 0X Fault Relay ROX ROX Define the fault relay Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 SPC3 11XX US Fax 858 578 4633 amp 888 FX INTEC www inteccontrols com Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 21 A RELEVANT SOLUTIONS COMPANY 3 7 9 Power On Time Gas sensors need a running in period until the chemical process of the sensor reaches stable conditions During this running in period the current signal can lead to an unwanted releasing of a pseudo alarm Therefore the power on time is started at the SPC3 after having switched on the power supply While this time is running out the Gas Controller does not activate any alarms The power on status occurs in the starting menu re Default Symbol Description Function y p Status 30 s Power On Time 30s XX Define the power on time sec Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605
15. F Relay OFF No gas alarm ON Relay ON Gas alarm or Reay Status i QFE Manual OFF Relay manual OFF Manual ON Relay manual ON 3 3 1 Manual Operation of the Relays The manual operation of the alarm relays is managed in the menu Relay Status If a relay is in the manual ON or OFF status the orange red alarm LED at the Gas Controller is lit continuously The external operation of the alarm relay via an assigned digital input has priority to the manual operation in the menu Relay Status and to gas alarm Relays manually operated in the menu Relay Status are deleted again by selecting the function Automatic Acknowledging the relays in latching mode is also effected in this menu Select the relay Select the function of manual operation En Manual ON Relay ON Select the function Manual OFF Relay OFF Automatic Delete manual operation Reset Reset of a latching mode Take over the function Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 10 3 4 Menu Sensor Reading A RELEVANT SOLUTIONS COMPANY In this menu the current value CV with gas unit and gas type for each ac
16. SPC3 11XX Page 04 A RELEVANT SOLUTIONS COMPANY Single Point Gas Controller SPC3 11XX 1 Description The PolyGard SPC3 Gas Controller is used for measuring monitoring and warning of toxic gases The toxic sensor SP01 is mounted inside One external gas transmitter SP02 for toxic combustible or refrigerant gases can be controlled additionally Four alarm Stage Set Points are free adjustable for each Sensor point SP Every alarm Stage Set Point can be assigned to one of the maximum 4 alarm outputs RX The Gas Controller can interface via the 0 4 to 20 mA or 0 2 to 10 V output signal with any compatible electronic analog control DDC PLC control or automation system The free adjustable setups and alarm Stage Set Point make a very flexible use in the gas measuring possible Simple and comfortable commissioning is possible due to factory adjusted setups The configuration setup settings and operation is easy to do without programming knowledge The PolyGard Single Point Gas Controller SPC3 must not be used in potentially explosive atmospheres The SPC3 may only be used within ambient conditions described in the Technical Data Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 Pol
17. according to the data sheet 0 250 ppm ex works adjustable between 0 150 and 0 300 ppm Pressure range Atmosphere 15 Storage time Max 6 months Mounting height 1 5 to 1 8m 5 to 6 ft Accuracy 3 ppm Stability amp resolution 3 ppm of reading Repeatability 3 of reading Long term output drift lt 5 signal loss year Response time toy lt 50 sec Life expectancy gt 5 years normal operating environment Humidity range short term 0 95 RH non condensing Temperature range continuous 10 C to 50 C 14 F to 122 F Temperature range short term 20 C to 50 C 4 F to 122 F Calibration adapter Fig 6 Type CONKIT E CH LC Cross sensitivity Concentration ppm Reaction ppm CO Acetone C3H O 1000 0 Acetylene C2H2 40 80 Ammonia NH3 100 0 Chlorine Cl 2 0 Ethanol C2 H50H 2000 5 Iso Propanol C3H0 200 0 Carbon dioxide CO2 5000 0 Nitrogen dioxide NO2 50 1 0 Nitric oxide NO 50 8 Sulphur dioxide SO 50 lt 0 5 Hydrogen Sulphide H2S 25 0 Hydrogen H2 100 20 Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 Fax 858 578 4633 amp 888 FX INTEC www inteccontrols com SPC3 11XX US Specification subject to change without notice
18. aches zero the failure signal is activated the following morning at 9 o clock and the phone no of the service technician occurs in the display The remaining days until the next maintenance can be read from the menu Maintenance in The service phone no can be entered individually in the next menu Symbol Description peta Function XXX Maintenance After Remaining days until the next maintenance XXX Maintenance Period 912 Reset of the maintenance message by entering the number of days until the next maintenance 0853 Phone No Input of the individual service phone no 3 7 4 For each active sensor point the Single Point Gas Controller calculates the arithmetic average value out of 10 measurements got within the time unit defined in the menu AV Time This average value is indicated in the menu Sensor Reading next to the current value At each sensor point the control mode current or average value is defined for the alarm evaluation Average Function The alarm evaluation of the control mode average value is overlaid by the current value when the current value exceeds the alarm Stage Set Point defined in the menu AV Overlay The overlay is delayed by the time factor defined in this menu Whit time factor O sec the overlay is not active er Default Symbol Description Status Function 120s AV Overla 120s sec Delay time of average value overlay 0 No overlay function 1
19. alarms of an SP ar Default z Symbol Description Status Function SP 01 Sensor Point Selection of SP No Gas concentration gt Stage Set Point Alarm is only activated at Qs o e the end of the fixed time sec O sec No Delay 2 Gas concentration lt Stage Set Point Alarm is only deactivated at Oe Delay sane Ore e the end of the fixed time sec 0 sec No Delay Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 17 A RELEVANT SOLUTIONS COMPANY 3 6 7 Control Mode Definition of the alarm evaluation by means of current CV or average value AV ar Default Symbol Description Status t Function SP 01 Sensor Point Selection of SP No CV Control by the current gas value GY Fva uation ev AV Control by the average gas value Current average value function see 3 7 4 3 6 8 SP Fault Assigned to Alarm Definition which alarms are activated in case of a fault at the measuring point dogs Default F Symbol Description Status Function SP 01 Measuring Point Selection of SP No Alarm 1234 0 Alarm not ON at SP failure Faut oo00 Felure SP 0000
20. ble after having removed the cause Select menu System Errors Example Failure SP 01 lt 3mA Reset the fault Fault reset Fault reset Cause not eliminated Reset not possible oo 3 1 2 Error Memory The menu Error Memory in the main menu System Error can only be opened via code level 2 In the error memory the last 15 faults are listed for the service technician even if they were already acknowledged in the menu System Error The deletion of each individual message is effected in the same way as the reset of a fault Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 08 3 1 3 System Errors The following system error messages are recorded SP 02 gt 22 mA Current signal at analog input gt 22 mA 11 VDC External Transmitter Cause Short circuit at analog input or transmitter not calibrated transmitter defective Solution Check cable to transmitter make calibration and replace the transmitter SP 02 lt 3 mA Current signal to analog input lt 3 mA 1 3 VDC External Transmitter Cause Wire breaking at analog input or transmitter not calibrated transmitter defective Solution
21. ction static flash Latching mode Horn function External relay operation Delay ON time Delay OFF time Finished SP mode Gas type Measuring range SP signal Stage Set Point 1 Stage Set Point 2 Stage Set Point 3 Stage Set Point 4 Hysteresis Delay ON time Delay OFF time C A mode Assigned failure lt gt alarm Assigned alarm lt gt alarm relay Assig SP sig lt gt analog output 1 SP 01 On Board Sensor SP 02 external Transmitter Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 Fax 858 578 4633 amp 888 FX INTEC www inteccontrols com cues INTEL CONTROLS A RELEVANT SOLUTIONS COMPANY SPC3 11XX US Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 26 CONTROLS A RELEVANT SOLUTIONS COMPANY 6 Configuration and Setup Card Commission Project No E ees Customer Commissioning Compay Y Commissioning Date Service Technician 6 1 Configuration Card of System Setups Service Software Maintenance Service AV Overlay Time Costumer Power Fault Version Date Phone ppm Time Av System Pass ON Relay Time Time Default GC 03 06 06 08 0853190040 120 120 1800 Eu 12
22. d idad 20 BL Analog Output dad da dido 20 3 7 8 Define the Failure Relay isitin ianiai iani aa aos iaa 20 3 7 9 Power OM TIME ezci esc tccescecdedetsnnedechnsacect DL de Dd 21 4 Mounting Electrical Connection ccceseeececeeseeeeeeeeeeeeeeeseeeeeeeeneeseeeneaeseseseaeeseseneaesesesaeseeseneaeeeeneenseeeeneaes 22 4 1 Electrical COMEN AE isa 22 4 2 Connection DiaQram cid AA A 23 4 3 Connector Block Overview SPC3 Module ooooooccconnnoccccnococccccononccnncnnancnnnnnonnnn naar o nc nr nano nc ar nnnn rra rrnnnn rca 24 Polygard is a registered trademark of MSR Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com SPC3 11XX US Specification subject to change without notice Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 03 CONTROLS A RELEVANT SOLUTIONS COMPANY D COMMISSION Mii a ia ia 24 Si COMMISSION IND cda A das 24 9 2 Checklist COMMISSIONING uta id diate aide 25 6 Configuration and Setup Card cccccccsssceeceeeeeeeeeeeneeeeeeeeneeeeseeneeeeseeeeeeeeseaeeeeeseeeesesseeneesaseeneesnseneeeaseaneeennes 26 6 1 Configuration Card of System SetupS ooommccccnnonnccnnnoccccconennncccnnoncnc cano cnn c nano nn nr EnA rra rr n nant rana rra 26 6 2 Configuration Card of Alarm Relays ooonnnoccnnnnnncinnnnocccnnnnonccnnnnnnonnnn nono cnn nano cn
23. ed i eet ee tee eta eee 8 3 35 Palay Status A A anaes 9 3 3 1 Manual Operation of the Relay ccoo ed e 9 3 4 Menu Sensor Reading iii a eed A ede ie eee ee a 10 3 0 Memi Relay Setups aa A ate eel oe Rn ede at 10 3 5 1 Relay Modes it A Beate fa ala aaa Rae el eee A 11 3 5 2 Relay Function Stalci Flash ict kaa bee al aetna net Gee ede 11 3 5 3 Latching Mode hata al da Ae eel ade oie ae oe 11 3 5 4 Horn FONCION cir ida p 12 3 5 5 External Relay Operation iaa lides 13 3 5 6 Delay Mode Of the Relay cocodrilo ici 13 3 0 Men SP Setups tati taba les 13 3 6 1 Activate Deactivate SP osise eiiiai dd dd edad 15 3 6 2 Selection Gas TYPO ocio a a A AE ATE E A E 15 3 6 3 Measuring Ranganna ne iiia i ais 16 SiG SP Sigal i sauce EAEE a aE ESE EEEN ANE EA ENE O T EA 16 3 6 5 Stage Set Point Hysteresis re e c 20s coh ine or neoa REI a a ania die 16 3 6 6 Delay oft Alan ON Or OR Pancita 16 JOT Control Mode cid 17 3 6 8 SP Faut Assigned CAAM o rene a i a teen 17 3 6 9 Alarm Assigned to Alarm Relay ooooococcconicicinonococccnnnonoccnnnono e aE Eee E a 17 3 6 10 SP Signal Assigned to Analog Output oooccccnnnncccinnnoccccnnnoncccnnnnonccnnnnn nc cnn nano rn cnn rr cn anar nr 17 ar Menu System Setups ii aaa 18 3 7 1 SOIVICO MODO cio A td ns 19 LEA Somware Verso maenas a E A et ees 19 3 7 3 Maintenance Concept dit 19 3 74 Average Func il cada 19 3 7 5 System Time System Date ita 20 3 7 6 Customer Password Code Tiida ida
24. ending on voltage input for unit max 50 mA Buzzer Acoustic pressure 83 dB A distance 300 mm 1 ft Frequency 3 5 kHz Serial Interface Transceiver RS 485 19200 Baud Heating Temperature controlled 3 2 C 38 F 36 F Ambient temperature 20 C 4 F Power consumption 0 5 A 12 VA Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 29 A RELEVANT SOLUTIONS COMPANY 8 Gas Sensor 8 1 Description The sensor is a micro fuel cell which is completely sealed The measurement is a gas in liquid chemical reaction rather than a surface area measurement With no surface area to coat this sensor retains its sensitivity to carbon monoxide even after prolonged exposure to clean air The cell consists of a diffusion barrier O ring seal electrolyte reservoir and two electrodes The target gas carbon monoxide enters the cell through a diffusion barrier The chemical process of the measurement is one of oxidation where one molecule of the target gas is exchanged for one molecule of oxygen The reaction drives the oxygen molecule to the counter electrode generating a DC microampere s
25. er Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 06 CONTROLS 2 3 Code Level A RELEVANT SOLUTIONS COMPANY Code Level 1 Default Password 1234 Code Level 2 Password 9001 All changes of setups and set point values are protected by a four digit numeric code password The code level 1 permits the operation of the SPC3 this code level is intended for the customer The code can be changed individually via code level 2 see section 3 7 6 In code level 2 all setups and set points are released this code level is only for the service technician Code level 2 cannot be changed or deleted The release of the code level is deleted if no button is pushed within 15 minutes All menu windows are visible without entering a code 3 Menu Overview The operation of the Single Point Gas Controller SPC3 is effected by a simple and logical menu structure that is easy to learn The operating menu contains the following levels e Starting menu e Main menu e Submenu 1 and 2 Starting menu Main menu Submenu a Display and reset of errors See from point 3 1 Displays the status of actual alarms See point 3 2 Display of the relay status Manual operation of the relays
26. ignal between the counter electrodes This signal is linear to the volume concentration of the sensed gas rather than the partial pressure The transmitter electronics will provide the necessary bias voltage when configured for one of these sensor types Most sensors produce a small amount of baseline current in clean air This is adjusted out with the zero push button on the transmitter This oxidation at the electrodes causes wear of the sensor Typical life for this sensor is approximately five years in normal operation This will vary somewhat from sensor to sensor with some working lifetimes less than five years and some more than 5 years This wear also changes the characteristics of the sensor requiring periodic re calibration with the potentiometer Gain It is recommended that the sensor accuracy be verified every twelve months and recalibrated as necessary 8 2 Calibration Required instruments to calibrate the transmitter e Test gas bottle with synthetic air or CO free ambient air e Test gas bottle with CO ppm in the range of 30 80 of the measuring range e Gas pressure regulator with flow meter to control the gas flow to 150 ml min e Calibration adapter with tube Type CONKIT E CH LC See fig 06 e Small screwdriver Note Please observe proper handling procedures for test gas bottles 1 Type gas depends on model 2 Flow rate depends on model and diameter of element 3 Calibration adaptor depends on model and dia
27. le Point Gas Controller SPC3 is prepared for both types of gas transmitters The classification of signals is defined in this menu Symbol Description estat Function SP 01 Measuring Point Selection of SP No Linear Transmitter with linear output signal Linear SP Signal Linear Non linear Transmitter with non linear output signal only AT series from MSR E 3 6 5 Stage Set Point Hysteresis For each sensor point four alarm Stage Set Points are available for free definition If the gas concentration is higher than the adjusted alarm Stage Set Point the associated alarm is set If the gas concentration falls below the alarm Stage Set Point inclusive hysteresis the alarm is again reset Unused alarm Stage Set Points have to be defined at measuring range end point in order to avoid false alarms At Oz measurement an alarm is released by a decreasing measuring signal Symbol Description ee Function SP 01 Measuring Point Selection SP No 50 Stage Set Point Gas concentration gt Stage Set Point 1 Alarm 1 100 1 Gas concentration gt Stage Set Point 2 Alarm 2 50 ppm Stage Set Point 100 Stage Set Point Gas concentration gt Stage Set Point 3 Alarm 3 250 2 Gas concentration gt Stage Set Point 4 Alarm 4 15 Stage Set Point Gas concentration lt Stage Set Point X 3 Hysteresis 3 6 6 Delay of Alarm ON or OFF Definition of alarm ON and or alarm OFF delay The function applies to all
28. ly to the sensor element e Apply calibration test gas CO 300 ml min 1 Bar 14 5 psi 10 e Wait two minutes until the measuring value is stable adjust the value with potentiometer Gain until the value corresponds to the Calibration gas concentration e Remove calibration adapter with a careful light turn Check the sensor for correct mounting By limiting the gain factor calibration will not be possible any more when the sensitivity of the sensor reaches a residual sensitivity of 30 Then the sensor has to be replaces 8 5 Exchange of Sensor Element Consider static electricity See point 3 Sensor should always be installed without power applied e Unplug old sensor element from the PCB e Take the new sensor out of the original packing e Plug in the sensor element into the PCB at X3 X7 e Calibrate according to section 8 Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 8 6 Specification Gas Sensor Page 31 IMEC CONTROLS A RELEVANT SOLUTIONS COMPANY Sensor performances Gas type Carbon monoxide CO Sensor element Electrochemical diffusion Measuring range standard other ranges
29. lygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605
30. meter of element 8 3 Zero Point Calibration Consider the running in period of the sensor at least 1 hour e Open window SP 01 in menu Measuring Value e Connect calibration adapter carefully to the sensor element e Apply synthetic air 150 ml min 1 Bar 14 5 psi 10 or CO free ambient air e Wait 1 minute until the measuring signal at SP 01 is stable push button Zero for 5 seconds After successful calibration the measuring signal is corrected automatically If the zero point is out of the admissible range gt 10 of measuring range before calibration there is no correction of the measuring signal The sensor has to be replaced e Remove calibration adapter carefully by turning lightly Check the sensor for correct mounting Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 30 A RELEVANT SOLUTIONS COMPANY 84 Gain Calibration Notes CO calibration gas is toxic never inhale the gas Symptoms Dizziness headache and nausea Procedure if exposed Take the victim into fresh air at once call a doctor e Open window SP 01 in menu Measuring Value e Connect calibration adapter careful
31. n anna ran nr EASE Ennan rn 26 6 3 Configuration Card of Measuring SetupS oooonnnccinnnnacocinnnoccccnnnoncnnnnnnnnn cnn nono nn nn rro nn nr nana rra 26 gt Specifications PO ar eked a aa aa pueda eae aE aa Ea r a aati 27 Bs GAS SONSOM T T T 29 8 1 Descriptions s need a ld 29 o AE O Ille E 1O a EAEE A A A T A A O T E A E E T 29 8 3 Zero Polnt Calibratie ra a aa a a ea a O a e a aa AESA 29 BA Gain Calibration siyer ae a ata a a aaaea a a e e aaee Chaat tibet S aaa aiae 30 9 5 Exchange of Sensor Eleme ee A 30 8 6 Specification Gas SEMSOM seeni ai i aa e i aaa Ea aara aa n aa a aaan i 31 9 Notes and General InformatioN cooomnonnoniccccnnnnnnnnnonnoncccncnnnnnnnnnonnncnnnn cnn sees none nn nene rre nn nn ne nnmnnn nnn nn nanne nne 32 9 1 Intended Product Application 0 cccccccccseccccceceeeeeeeeeeeaeee eee eeeeeeeeeaeaeceeeeeeeesaeeaeaeeeeeeeeeseeseaeeeeeteneeeeaees 32 9 2 Installers Responsibilities mrina mnai aa a aa a a arana aa ea a a adaa aiea AE 32 9 3 Maintenance esnan i thet a o aa a a a T 32 g4 L Limited Warna eaea EAE A A T E E A iaa 32 Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller NEC User Manual
32. of the defined time sec 0 sec No delay 3 6 Menu SP Setups Display and change of setups assignment of alarms to alarm relays and activation of Sensor Points SP Main Menu Selection of SP Activate or deactivate SP See 3 6 1 Define gas type See 3 6 2 Define measuring range See 3 6 3 Adjust signal form of the transmitter See 3 6 4 Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller NEC User Manual SPC3 11XX Page 14 A RELEVANT SOLUTIONS COMPANY Define Stage Set Point 1 See 3 6 5 Define Stage Set Point 2 See 3 6 5 Define Stage Set Point 3 See 3 6 5 Define Stage Set Point 4 See 3 6 5 Hysteresis See 3 6 5 Set delay time ON See 3 6 6 Set delay time OFF See 3 6 6 Define control mode See 3 6 7 Assign SP fault to alarm See 3 6 8 Assign alarm to alarm relay See 3 6 9 and 3 6 10 Assign SP signal to analog output See 3 6 10 di HHHH Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 8 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontr
33. ol Description Status Function R01 Relay No Selection of relay De P De energized Alarm ON Relay ON energized Reay Moce energized Energized Alarm ON Relay OFF 3 5 2 Relay Function Static Flash Definition of relay function ds Setting Symbol Description Status Function R01 Relay No Selection of relay O Relay function static 0 Function 0 gt 0 Relay function flashing Time period in sec Impulse Break 1 1 3 5 3 Latching Mode Definition of latching function a Setting Symbol Description Status Function R01 Relay No Selection of relay No Latching mode non active Mo nalening Mode No Yes Latching mode active Acknowledging a latching relay in the menu Relay Status is only possible if the gas concentration is again lower than the alarm Stage Set Point including hysteresis In this case the status latching occurs in the display Example Alarm relay R2 with latching mode On Alarm 2 e Gas concentration higher lower than threshold Display in the Menu R2 R2 R2 R2 R2 R2 Status Relay off On On On _Latching Off Relay 2 On o On oJ E l Reset in the Menu Status Relay Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 P
34. ols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX cues UNEL CONTROLS A RELEVANT SOLUTIONS COMPANY 3 6 1 Activate Deactivate SP Symbol Description Setting Function Status SP 01 Measuring point Selection SP No Active SP Status Not Active B Sensor point activated at the controller active Not active Sensor point not activated at the controller SP01 On Board sensor SP02 External Transmitter optional 3 6 2 Assign gas type to attached gas transmitters Selection Gas Type Symbol Description pally Gas type Unit set a SP 01 Measuring point CO Carbon monoxide ppm 0 250 Ex Combustible gas LEL 0 100 NO Nitrogen oxide ppm 0 50 NO Nitrogen dioxide ppm 0 25 NH3 Ammonia ppm 0 300 O Oxygen VIV 0 25 CO Carbon dioxide ppm 0 2000 SO Sulphur dioxide ppm 0 100 H2S Hydrogen sulphide ppm 0 200 CL Chlorine ppm 0 100 ETC Ethylene oxide ppm 0 20 VOC Air quality 0 100 R401 Refrigerant gas ppm 0 2000 R402 Refrigerant gas ppm 0 2000 R408 Refrigerant gas ppm 0 2000 R409 Refrigerant gas ppm 0 2000 R404 Refrigerant gas ppm 0 300 R416 Refrigerant gas ppm 0 300 R502 Refrigerant gas ppm 0 300 R410 Refrigerant gas ppm 0 300 R411 Refrigerant gas ppm 0 300 R11 Refrigerant gas ppm 0 300 R123 Refrigerant gas ppm 0 300 R134 Refrigerant gas ppm 0 300 R22 Refrigerant gas ppm 0
35. olyGard Single Point Controller INTEC User Manual SPC3 11XX Page 12 a A RELEVANT SOLUTIONS COMPANY 3 5 4 Horn Function The internal horn is connected to alarm relay R3 open collector This alarm output is defined as horn relay by this setup with the following possibilities to reset e By pressing any of the 4 push buttons only possible in the starting menu e Automatic reset at the end of the fixed time e By an external push button assignment of the appropriate digital input The horn function is only activated if at least one of the two setups time or digital input is set Special function Response After acknowledging the output by push button or externally time starts When this time has run out and the alarm is still acting the relay is set again ae Setting Symbol Description Status Function R03 Relay No Selection of relay 0 Reset of the relay after time having run out or by push button Quit Mode 0 1 Reset of the relay by push button after time having run out and when alarm is still acting relay is set again Response function Time for automatic reset function or response function Time 120 0 no reset function DI 0 Assignment which digital input resets the output Acknowledge the horn output On Alarm 3 or Gas concentration higher lower than threshold Time On Relay 3 off Acknowledging On signal of Special function Response Return of the ho
36. oof Alarm relay R1 30 VAC DC 0 5 A potential free SPDT Alarm relay R2 30 VAC DC 0 5 A potential free SPNO SPNC Binary output R3 R4 R3 30VDC 05 A Internal Buzzer R4 30VDC switch output 30 VDC 0 05 A open collector output Visualization Display Two lines each 16 characters Status LED 4 Normal operation Fault Alarm 1 Alarm 2 Operation 4 push buttons menu driven Operation Environment Humidity 15 90 RH non condensing Working temperature 10 C to 50 C 14 F to 122 F Storage temperature 5 C to 30 C 23 F to 86 F Pressure range Atmospheric 10 Physical Enclosure panel Material Polycarbonate UL 94 HB fire retardant Conformity UL 50 standards Color Light Grey Dimensions W x H x D 130 x 130 x 75 mm 5 12 x 5 12 x 2 95 in Weight Approx 0 6 ibs 0 3 kg Protection class NEMA 12 IP55 Installation Wall surface mounted 3 holes for 1 2 in conduit for wall surface c mounted and 1hole on back side of base plate Cable entry for single gang electrical box mounting Wire connetion Terminal blocks Wire size Min 24 AWG 0 25 mm2 Max 14 AWG 2 5 mm2 Wire distance Max loop resistance 450 Ohm Wire distance plus controller input resistance Enclosure Metal Material galvanized steel w zinc coating corrosion resistant Color RAL 7032 light grey
37. r has one analog output AO01 with 0 4 to 20 mA 0 2 to 10 V signal The signal of SP01 or and SP02 can be assigned to the analog output The assignment is effected in the menu SP Setups for each SP The sensor point sends the signal which is defined in the menu C A Mode The output signal mA V and starting point 0 20 is selected at the I O Board by means of jumper See fig 5 Out of the signals of all assigned measuring points the Single Point Gas Controller determines the minimum the maximum or the average value and transmits it to the analog output The definition which value is transmitted is effected in the menu Analog Output 1 The analog output can be calibrated at 4 and at 20 mA only in mA mode Therefore an ampere meter measuring range 25 mA can be attached to the AO and the respective factor has to be changed until the analog output corresponds to 4 and or 20 mA During calibration evaluation of the sensor point signals is not possible This calibration is effected by the factory The factors shall not be changed oar Default Symbol Description Status Function Select Min Displays the minimum value of all assigned SP Max Output Mode Max Max Displays the maximum value of all assigned SP P Average Displays the average value of all assigned SP 4 0 Calibration 4 0 4 Calibration factor at 4 mA 20 0 20 0 20 0 Calibration factor at 20 mA 3 7 8 Define the Failure Relay
38. rn rela On Alarm 3 bi Gas concentration higher lower than threshold Time Time gt lt On lt gt Relay 3 off Acknowledging On signal t l Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller INTEC User Manual SPC3 11XX Page 13 3 5 5 External Relay Operation A RELEVANT SOLUTIONS COMPANY Assignment to a digital input DI for external switching of the alarm relay ON and or OFF This function has priority to gas alarm and or manual switching in the menu Relay Status Symbol Description ae Function R01 Relay No Relay Selection DI ON External On 0 If digital input closed relay switches ON DI OFF External Off 0 If digital input closed relay switches OFF 3 5 6 Delay Mode of the Relay Delay time ON starts when the alarm is released and or delay time OFF starts when the alarm returns to normal condition Pp Setting Symbol Description Status Function R01 Relay No Relay Selection Os Delay Time ON 0 Mode ON Relay is only activated at the end of the defined time sec 0 sec No delay Os Delay Time OFF 0 Mode OFF Relay is only deactivated at the end
39. the PolyGard SPC3 system regularly Due to regular maintenance differences in efficiency can easily be corrected Limited Warranty Re calibration and part replacement may be implemented in the field by a qualified technician and with the appropriate tools Alternatively the easily removable plug in transmitter card with the sensor may be returned for service to INTEC Controls 9 4 Limited Warranty MSR Electronic GmbH and INTEC Controls warrants the PolyGard SPC3 for a period of two years 12 months normal exposure for the sensor from the date of shipment against defects in material or workmanship Should any evidence of defects in material or workmanship occur during the warranty period INTEC Controls will repair or replace the product at their own discretion without charge This warranty does not apply to units that have been altered had attempted repair or been subject to abuse accidental or otherwise The warranty also does not apply to units in which the sensor element has been overexposed or gas poisoned The above warranty is in lieu of all other express warranties obligations or liabilities This warranty applies only to the PolyGard SPC3 MSR Electronic GmbH and or INTEC Controls shall not be liable for any incidental or consequential damages arising out of or related to the use of the PolyGard SPC3 If the PolyGard SPC3 needs to be returned to INTEC Controls for service an RMA number must be obtained prior to sending Po
40. the terminals see the following connection diagram Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 4 2 Connection Diagram ceo UNEL CONTROLS A RELEVANT SOLUTIONS COMPANY Connection diagram with Option external Transmitter 4 to 20 mA Fig 2 Option external Transmitter MP 02 4 20 mA 24 VDC Analog output O VDC 0 4 20mA 0 2 10 V SPC3 Digital X5 Input DIO 1 ext Buzzer 7 Bus_B 2 6 Bus_A R3 24 3 5 4 20 mA_Inp 4 OV fra 4 Analog_Out 5 Warning 3 24 VDC_Out ay 6 NO_1 Flash light been 2 0 voc R1 H7 nca 1 24 VDC 8 COM_1 9 COM_2 x4 R2 210 NO NC_2 0 Q 11 eee Analog Output Signal R1 SPDT 30 VAC DC 0 5A Selecttable via Jumper R2 SPNO SPNC 30 VAC DC 0 5 A R3 R4 Open Collector 30 VDC 50 mA Connection diagram with Option external Transmitter 0 2 to 10 V SPC3 Fig 3 Option external 7 Bus_B
41. tive sensor point SP is displayed At control mode average value AV is the average value additional displayed Symbol Description Ei Function SP 01 Measuring P No Selection of SP No CO Gas type CO See 3 6 2 ppm Gas unit See 3 6 2 CV Current value CV Current value of gas concentration AV Average value Average value 10 measured values within the time unit i Control mode Display of selected control mode CV or AV Not active Status SP Not active SP not active Error Fault SP Current signal lt 3 mA or gt 22 mA 3 5 Menu Relay Setups Display and change of the setups for each alarm relay Main menu Select relay No Relay mode See 3 5 1 Relay function See 3 5 2 Activate latching mode See 3 5 3 Definition of horn function See 3 5 4 Definition of external relay operation See 3 5 5 Set delay time ON See 3 5 6 Set delay time OFF See 3 5 6 Polygard is a registered trademark of MSR SPC3 11XX US Customer Services 858 578 7887 8 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 110 Poway CA 92064 www inteccontrols com Printed in USA 150605 PolyGard Single Point Controller User Manual SPC3 11XX 3 5 1 Relay Mode Definition of relay mode en INTEL CONTROLS A RELEVANT SOLUTIONS COMPANY re Setting Symb
42. yGard Single Point Controller INTEC User Manual SPC3 11XX Page 05 A RELEVANT SOLUTIONS COMPANY 2 Operating Instruction The complete configuration parameterization and service are made via keypad user interface in combination with the display screen Security is provided via two password levels O Alarm 1 Alarm 20 GIO 2 1 Description Keypad User Interface Enter Main Menus scrolls through Main Menus and Sub Menus increase or decrease a value Navigates through menus on the same level moves cursor when inputing data Exit programming mode and saves settings return to previous level or menu Enter Sub Menus accepts and stores data silence horn if assigned LED orange Flashes when alarm one or more alarms are active Permanently on when one of the relays is manually operated LED red Flashes when alarm two or more alarms are active Permanently on when one of the relays is manually operated LED yellow Flashes at system or sensor failure or when maintenance needed LED green Power LED 2 2 Setting Changing Setups or Set points Open desired menu window Code window opens if no code level approved After inputting the valid code the cursor jumps on the first position segment to be changed gt Push the cursor onto the position segment which is to be changed 4 Change the setup set point Save the changed value Finish Polygard is a registered trademark of MSR SPC3 11XX US Custom

Download Pdf Manuals

image

Related Search

Related Contents

User Manual for Scribe 3.0  Untitled - Spencer  Vigo VGAC005BN Instructions / Assembly  Sharp XL-UH12H home audio set  MANUAL DE INSTRUCCIONES COD.19050K-19050    