Home

user manual remote controller

image

Contents

1. TIMER OFF Button Press this button to activate the Auto off time setting Each press will increase the time setting in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto off time setting just press the button until the time setting is 0 0 LOCK Button For RG51Q and RG51J models only Press this recessed button to lock all current settings and the remote controller will not accept any operation except that of the LOCK Use the LOCK mode when you want to prevent settings from being changed accidentally Press the LOCK button again to cancel the LOCK function A lock symbol will appear on the remote controller display when the lock function is activated NOTE For RG51Q1 models press the TEMP UP A and DOWN y button simultaneously for 3 seconds to activate cancel the LOCK function C H Button For RG51Q1 models only Press this recessed button to shift the mode between Cooling only and Cooling amp Heating according to the feature of the machine The factory default setting mode is Cooling amp Heating For example the unit you purchased is Cooling only models please press this recessed button with a needle of 1mm to shift the operation mode 5 Indicators on LCD SET TEMPERATURE Lt Ui co c gt TIMER ON OFF MODE display Displays the current selected mode Including AUTO COOL DRY HEAT cooling amp heating models only and FAN Transmissi
2. TIMER OFF Auto off Operation The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed The air conditioner will stop automatically at the set time Example To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of stopping operation time and the signal h will show on the display area 2 Press the TIMER OFF button to display 10h on the TIMER OFF display of the remote controller 3 Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF gt TIMER ON On Stop Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home Example To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press the TIMER OFF button 2 Press the TIMER OFF button again to display 2 0h on the TIMER OFF display 3 Press the TIMER ON button 4 Press the TIMER ON button again to display 10h on the TIMER ON display 5 Wait for the remote control to display the setting temperature ee TIMER ON gt TIMER OFF h Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop
3. The remote controller is powed by two dry batteries RO3 LRO3X2 housed in the rear part and protected by a cover 1 Remove the cover by pressing and sliding off 2 Remove the old batteries and insert the new batteries placing the and ends correctly 3 Reattach the cover by sliding it back into position NOTE When the batteries are removed the remote controller erases all programming After inserting new batteries the remote controller must be reprogrammed ACAUTIONS e Do not mix old and new batteries or batteries of a different type Do not leave the batteries in the remote controller if it is not going to be used for 2 or 3 months e Dispose of the old batteries in the special containers to be found in the sales outlets Remote Controller Specifications Model RG51Q BG C E RG51Q1 BG C E RG51J 1 C E RG511J 1 BG C E Rated Voltage 3 0V Dry batteries R03 LR03 X 2 Lowest Voltage of 20V CPU Emitting Signal l Signal Receiving 8m when using 3 0 voltage Range it Gets 11m Environment 5 C 60 C Performance Feature 1 Operating Mode AUTO COOL DRY HEAT Cooling amp heating models only and FAN 2 Timer Setting Function in 24 hours 3 Indoor Setting Temperature range 17 C 30 C 4 Full function of LCD Liquid Crystal Display Note e Buttons design might be slightly different from the actual one you purchased depending on individual models All the functions described a
4. When the louver swing or move to a position which would affect the cooling and heating effect of the air conditioner it would automatically change the swing moving direction 8 Timer operation press the TIMER ON button can set the auto on time of the unit And press the TIMER OFF button can set the auto off time of the unit To set the Auto on time SET TEMPERATURE C 1 Press the TIMER ON button The remote controller shows TIMER ON the last Auto on setting time and the signal h will be shown on the LCD display area Now it is ready to reset the y ADJUST A Auto on time to START the operation C Je 2 Push the TIMER ON button again to set desired Auto on time Each time you press the button MODE ON OFF FAN SPEED the time increases in 30 minutes increments up WING Eco TIMERON to 10 hours then at 1 hour increments up to 24 hours pesna 3 After setting the TIMER ON there will be a one half second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display window To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last Auto off setting time and the signal h will be shown on the LCD display area Now it is ready to reset the Auto off time to START the operation 2 Pus
5. K O O TIMER OFF SET TEMPERATURE C y ADJUST A Ge ae MODE ON OFF DIRECTION WING f ECO Co CO SWING RESET LOCK FAN SPEED TIMER ON TIMER OFF Dehumidifying operation Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the indoor unit illuminates 1 Press the MODE button to select DRY mode 2 Press the TEMP button to set the desired temperature The temperature can be set within a range of 17 C 30 Cin 1 C increments 3 Press the ON OFF button to start the air conditioner NOTE In the Dehumidifying mode you can not switch the fan speed It has already been automatically controlled Swing operation Use the DIRECTION SWING button to adjust the horizontal louver use the SWING button to adjust the vertical louver 1 For RG51Q BG C E models when press the DIRECTION SWING button the louver changes 6 degree in angle for each press If keep pushing more than 2 seconds the louver will swing up and down automatically Press the SWING button the vertical louver will swing left and right automatically 2 For RG51J C E models when press the SWING button the louver will swing up and down automatically 3 For RG51Q1 BG C E models press the SWING or button the horizontal or vertical louver will swing automatically when press the AIR DIRECTION button the louver changes 6 degree in angle for each press NOTE
6. USER S MANUAL SINCLAIR AIR CONDITIONING CONTENTS Handling the remote Controller pp Remote controller Specifications pp FUINGCUON DUONG secsccssecassstess pisadas Enia indicators n LOD oiveicaticieccsianesncnitmataneceavinwctexadcnnepecsiaanaancsesoacaracsand How to use the buttons et Auto operatio Micii i Cooling Heating Fan operation pp Dehumidifying operation pe Swing ODEE AU ON aise neecenenessneasdexateaensenousentuescaisanaadnwesasaaedisiuaesennands Timer operation 4 ECO OPEL AMON steresenececetsnensccawsciseseschcacessessannaessesatcanneaedonniceavessesosas Handling the remote controller Location of the remote controller ACAUTIONS e Use the remote controller within a distance of 8 meters from the appliance pointing it towards the receiver Reception is confirmed by a beep e The air conditioner will not operate if curtains doors or other materials block the signals from the remote controller to the indoor unit e Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat e f the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver e f other electrical appliances react to the remote controller either move these appliances or consult your local dealer Replacing batteries
7. ackaging indicate such disposal procedures The materials are recyclable in accordance with their respective symbols By EE means of re use material recycling or any other form of recycling old appliances you are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label The value GWP 2088 GWP Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center Emergency number 112 PRODUCER Producer SINCLAIR CORPORATION Ltd 1 4 Argyll St London W1F 7LD UK www sinclair eu com This product was manufactured in China Made in China REPRESENTATIVE AND TECHNICAL SUPPORT NEPA spol s r o Purkynova 45 612 00 Brno Czech Republic Tel 420 800 100 285 WwWw nepa CZ
8. h the TIMER OFF button again to set desired Auto off time Each time you press the button the time increases in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours 3 After setting the TIMER OFF there will be a one half second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display window 9 IMPORTANT e The effective operation time set by the remote controller for the timer function is limited to the following settings 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 8 5 9 0 9 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 and 24 Example of Timer setting TIMER ON o Auto on Operation Ceti h The TIMER ON feature is useful when you want TIMER ON the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time Start Example To start the air conditioner in 6 hours 1 Press the TIMER ON button the last setting of apl 2 starting operation time and the signal h will show on the display area 2 Press the TIMER ON button to display 6 0h on the TIMER ON display of the remote controller 3 Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated
9. it after you leave the house Example To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button TIMER ON OFF 2 Press the TIMER ON button again to Off j Stop display 2 0h on the TIMER ON display 3 Press the TIMER OFF button Set 2 hours later 5 hours later 4 Press the TIMER OFF button again to after setting after setting display 5 0h on the TIMER OFF display 5 Wait for the remote control to display the setting temperature e The timer setting TIMER ON or TIMER OFF that in sequence occurs directly after the set time will be activated first SETTEMPERATURE C ECO operation The ECO function enables the unit to automatically increase cooling or decrease heating 1 C per hour for the first two hours then hold steady for y ADUS A the next 5 hours after that the unit will stop C JC operation It can maintain the most comfortable MODE _ ONOFF FAN SPEED temperature and save energy DIRECTION SWNG ECO TIMERON NOTE The ECO function is only available under eiin Cooling Heating and AUTO operation SWING4 RESETLOCK TIMER OFF O O NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the p
10. o select Auto 2 Press the TEMP button to set the desired temperature The temperature can be set within a range of 17 C 30 C in 1 C increments 3 Press the ON OFFbutton to start the air conditioner NOTE 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan Heating and Dehumidifying by sensing the difference between the actual ambient room temperature and the set temper ature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 If the Auto mode is not comfortable for you the desired mode can be selected manually Cooling Heating Fan operation Ensure the unitis plugged in and power is available 1 Press the MODE button to select COOL HEAT cooling amp heating models only or FAN mode 2 Press the TEMP button to set the desired temperature The temperature can be set within a range of 17 C 30 C in 1 C increments 3 Press the FAN SPEED button to select the fan speed in four steps Auto Low Med or High 4 Press the ON OFF button to start the air conditioner NOTE In the FAN mode the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either In this case only step 1 3 and 4 may be performed Q SET TEMPERATURE C ADJUST A MODE ON OFF FAN SPEED DIRECTION RANGT ECO TIMER ON Ce CO SWING RESETLOC
11. on Indicator This transmission indicator will light when remote controller transmits signals to the indoor unit Temp Timer display The temperature setting from 17 C to 30 C or timer setting 0O 24h will be displayed If FAN mode is selected there will be no display ON OFF display This indicator will be displayed when the unit is operating MODE display FAN mode FAN SPEED display Displays the selected fan speed AUTO HIGH MED if applicable and LOW Nothing displays when the fan speed is selected in AUTO speed When AUTO or DRY Mode is selected there will be no signals displayed TIMER display This display area shows the settings of the TIMER That is if only the Auto on time function is set it will display TIMER ON If only the Auto off time function is set it will display TIMER OFF If both functions are set it will display TIMER ON OFF which indicates you have chosen both the Auto on time and Auto off time LOCK Indicator LOCK display is displayed when pushing the LOCK button Push the LOCK button to clear display SET TEMPERATURE C RWG Eco TIMERON CICI SWING ReserLock TIMER OFF oo C SET TEMPERATURE C DIRECTION SWING t ECO TIMER ON SWING pesetiock TIMER OFF O O How to use the buttons Auto operation Ensure the unitis plugged in and power is available The OPERATION indicator on the display panel of the indoor unit illuminates 1 Press the MODE button t
12. re accomplished by the indoor unit If the indoor unit has no this feature there is no corresponding operation happened when press the relative button on the remote controller Function buttons SET TEMPERATURE C y ADJUST A MODE ON OFF FAN SPEED DIRECTION WING f ECO TIMER ON SWING pesetlock TIMER OFF RG51Q BG C E SET TEMPERATURE C y ADJUST A MODE ON OFF FAN SPEED SWING ECO TIMERON SWING peser cy TIMER OFF oo AIR DIRECTION RG51Q1 BG C E TEMP UP Button Push this button to increase the indoor temper ature setting in 1 C increments to 30 C TEMP DOWN Button Push this button to decrease the indoor temper ature setting in 1 C increments to 17 C MODE Button Each time the button is pressed the operation mode is selected in the sequence of the following NOTE Heat mode is for Cooling amp Heating models only DIRECTION SWING Button For RG51Q models Used to stop or start horizontal louver move ment or set the desired up down air flow direction The louver changes 6 degree in angle for each press If keep pushing more than 2 seconds the louver will swing up and down automatically SWING Button For RG51Q1 models SWING Button For RG51J models Used to stop or start horizontal louver move ment SWING Button 4 For RG51Q 1 models Used to stop or start vertical louver move ment AIR DIRECTION Button For RG51Q1models Used to set the de
13. sired up down air flow direction The louver changes 6 degree in angle for each press RESET Button Once the recessed RESET button is pressed all of the current settings will be cancelled and the controller will return to the initial settings ON OFF Button Operation starts when this button is pressed and stops when the button is pressed again FAN SPEED Button Used to select the fan speed in four steps prAuto Low Med High 7 NOTE Med fan speed is not available for RG51J models Q Function buttons continued SET TEMPERATURE C TEMP A m MODE ON OFF FAN SPEED es TIMER ON RESETLOCK TIMER OFF O O RG51J 1 C E SET TEMPERATURE C y ADJUST A CIC MODE ON OFF FAN SPEED C SWING ECO TIMERON SWING peser c TIMER OFF O Q AIR DIRECTION RG51Q1 BG C E TIMER ON Button Press this button to activate the Auto on time setting Each press will increase the time setting in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto on time setting just press the button until the time setting is 0 0 ECO Button Select this function during the sleeping time It can maintain the most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only NOTE While the unit is running under Energy saving mode it would be cancelled if press MODE FAN SPEED or ON OFF button