Home
Eurosec CPX User guide - Home Security Systems
Contents
1. 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show for example Do you want to Set NAOMI 3 Press NO three times the display will show Do you want to View the LOG 4 Press YES the display will show for example Read Log 01 JAN 18 58 01 Page 9 User Manual eur sec CPX 5 This is the most recent event in the log Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forward to the next event Pressing 7 will take you to back to the last event of the previous day Pressing 9 will take you forward to the first event of the next day 6 When you have finished viewing the Log press 0 twice the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Changing The Chime Status Master code only The Chime zones will have previously been programmed by the installation company A Master level code may change the status of the Chime between On and Off To do so proceed as follows 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show for example Do you wantto Set NAOMI 3 Press NO four times the display will show Do you want to Change Chime
2. Press 0 to return to lt lt lt lt UN SET gt gt gt gt 01 Jan 00 00 01 Page 18 eur sec CPX User Manual Using Vo Comm if fitted Once Vo Comm has been programmed see previous page the Vo Comm will operate in one of two ways 1 Alarms Only The Vo Comm will only communicate when an alarm occurs on a Closed Set system This mode is active when the Open Close option is Off 2 Alarms amp Status The Vo Comm will communicate when an alarm occurs or when the system is Closed or Opened Set or Unset Receiving a Call From Vo Comm When Vo Comm calls you it will start to pass its message as soon as you pick up the telephone At the end of the message you will hear a single tone at this point press a key on your telephone keypad twice A rising tone will be heard that indicates that the call has been acknowledged If you do not acknowledge the call or hear the rising tone the Vo Comm will repeat the message several times and then go on to dial the remaining telephone numbers until the call is acknowledged Messages From Vo Comm Two types of message will be sent by Vo Comm Either a status message or an alarm message Typical Status Message Site 05 Close OT This would indicate Site ID 05 was Closed by User 1 The term Closed Set The term Open Unset Note In order for the Vo Comm to report Openings and Closings the Open Reporting for that user must
3. Page 10 eur sec CPX User Manual 4 Press YES the display will show for example Chime is Off ok Dr Chime is On ok 5 Press NO to change the status of the Chime then press YES the display will show Do you want to Change Chime 6 Press 0 to escape the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Page 11 User Manual eur sec CPX Programming User Codes Master code only The charts on pages 2 amp 30 should be completed by the engineer user for future reference of what codes have been allocated on your system Under no circumstances should the actual user code be written down If your installation company has given you keyswitches for the operation of your system some user codes may have been reserved for use by these keyswitches If your engineer has indicated see pages 2 amp 31 that some of the user numbers on your system have been reserved you should not use them whilst programming user codes If you do so your system may be adversely affected 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show Do you want to Set NAOMI 3 Press NO five times the display will show Do you want to Prog USER CODES
4. 4 Press YES the display will show Enter User No 1 15 Then YES 5 Enter the user number 1 to 15 that you wish to program followed by YES the display will show Now Enter Code Then YES Page 12 eur sec CPX User Manual 6 Note Note 10 11 Enter the code you require codes may be 4 5 or 6 digits followed by YES Entering 000000 will delete an existing code If the code already exists or is a duress of another code an error will be shown choose another code and return to step 6 The display will show not if user 1 is being programmed Code Type Press No until the require level of code is shown Master ok Refer to page 3 for code level details Refer to Advanced Code Programming for details for User level of Control Press Yes the display will show for example l Code Group Code Groups are only used in conjunction with None controlling outputs See Advanced Code Programming section for details Press Yes The display will show VoComm Trigger This determines if using this user code to Set or On Ok Unset the system will trigger the Vo Comm for more details on Vo Comm please refer to the Vo Comm section Press No until the setting you require is displayed Yes or No The Vo Comm will need to be programmed in order for this option to work please refer to the Vo C
5. Please WAIT Connect lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 ERROR Try Again eur sec CPX User Manual Resetting After an Alarm Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your system is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user code followed by YES if Master or Main code is used the exit tone will sound and the display will show for example EXIT Now All Zones ON A 2 Enter the code again to abort the setting Time will count down 3 The system is now reset Or If a higher level of code is required one of the following displays will be shown Can t Set Use Master Code Use a Master code to reset the system Or Can t Set Use Call the installation company ENGNR Code Or Can t Set Use Call the central station or installation company ENGANN Code 1294 as instructed and quote the number given Or Can t Set Use Anti Code 1234 Page 21 User Manual eur sec CPX 4 To reset the system with an anti Code contact the central station
6. then YES or NO then YES or NO Enter Zone No Do you want to Set NAOMI User Manual eur sec CPX Testing The System Master amp Main codes only 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master or Main level code the display will show Do you want to Set NAOMI 3 Press NO the display will show Do you want to REMOVE Zones 4 Press NO the display will show Do you want to TEST the System 5 Press YES to test the system 6 The display will show 1 Status 4 Strobe 6 Sounder 9 Bell 7 Then for example lt All Zones OK gt TESTING 8 Pressing 1 will enter zone Status mode All zones will show on the display and will be deleted as each zone is triggered Press 0 to escape Pressing 6 will silence the internal sounder Pressing 4 will toggle the Strobe On Off Pressing 9 will toggle the Bell On Off Page 8 eur sec CPX User Manual 9 Whilst in Test mode any zones violated will sound the internal sounder if it has not been silenced and show on the display 10 When you have finished testing the system press 0 twice the display will show lt lt lt lt UNSET gt gt gt gt 01 JAN 18 58 01 Viewing The Event Log Master code only
7. GardTec Ltd Commerce House Whitbrook Way Stakehill Distribution Park Middleton Manchester M24 2SS United Kingdom Internet www gardtec ltd uk e mail sales gardtec Itd uk INVESTOR IN PEOPLE Certificate No 935289 5INEW021UM
8. eurosec G Control Panel User Instructions eur sec CPX Contents User Information Introduction User Code Types Setting The SYSTEM zs esse hopen sind enat karens ees Setting amp Unsetting via Keyswitch Unsetting The System snmmsnssssessssrsroresresnrenresrsnrenr sn rann nn Part Setting The System REMOVING Zones Testing The System Viewing The Event Log Changing T he Chime Status Programming User Codes u 222004224004nnnenne nennen Programming Time amp Date Vo Comm Introduction Vo Comm Programming Using Vo Comm Us Messages f rom VO COMMM ueeeeeeneennnnnnnnnnnnnnnnnnnnnennnnnnn User Initiating Remote Access nennen Resetting After An Alarm Duress Codes 2 22 3 us G Tag Introduction Programming G Tag 2244424unsnnen nennen nennen USING G Tag rn 2er a Display Status Blanking 2 4 20erssen nennen Keypad Tamper nennen System TAM PES screed eae alee eats Mains Failu TO reset are nie tes diese tenues Advanced Code Programming Using Advanced Codes 22u42404220nnnnnnnennnnennnnen nen System Attr IDULES H ra rire nme gyes AE S rvice R Cord 022 20 nein User Chart N oO on
9. Page 4 eur sec CPX Unsetting The System 1 Enter the premises via the authorised entry route the broken entry tone will sound proceed to the keypad 2 At the keypad enter a valid code the display will show 3 The system is now unset User Manual lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Note G Tag Proximity Tags may be used for setting and unsetting the system Please refer to the Using G Tag section for instructions Part Setting The System using Master amp Main type codes 1 With the display showing 2 Enter a Master or Main type code the display will show for example 3 Press 1 2 or 3 for Part 1 2 or 3 the display will show for example Note Your installation company will have informed you what zones are being removed omitted for the Part Set you are using Refer to the System Attributes section for what zones have been programmed as Part Set zones Page 5 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you want to Set NAOMI EXIT Now Part 1 15 Time will count down User Manual eur sec CPX 4 The exit tone may or may not be heard dependant on the system settings programmed by the installation company Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop if the exit to
10. gt BW D 1 o Oo 1 oO 10 11 12 14 15 16 16 18 19 19 20 21 22 23 24 24 24 25 25 25 26 27 27 28 29 29 User Manual User Manual eur sec CPX User Information Customer Name Customer Address Control Panel Model eur sec CPX No of Keypads pad 1 Location pad 2 Location pad 3 Location pad 4 Location G Tag 1 Location G Tag 2 Location Keyswitch Location if fitted Reserved User Code User No Installation Company Name Installation Company Address Installation Compan Other Information Note This section to completed by the installation engineer Page 2 eur sec CPX User Manual Introduction The eur sec CPX control Panel is a microprocessor based unit with multiple user and engineer programmable options Control of the system is via LCD Remote Keypad RKP giving two rows of 16 character English text Facility is provided model dependant for Central Station and or Vo Comm message communication to inform of system status and alarm events Vo Comm messages may be sent to standard land line telephones or mobile telephones Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual Your installation company will give training on the use of the equipment in order to comply with the relevant standards and will be able to answer specific questions about your system request for
11. sec CPX see Using Duress Section Page 3 User Manual Setting The System 1 With the display showing 2 Enter the User code followed by YES if Master or Main type code has been used The display will show and a continuous exit tone will sound 3 Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit 4 Once the premises are secure listen from outside the protected area that the exit tone returns to the continuous tone 5 Wait until the exit tone finishes before leaving Note G Tag Proximity Tags may be used for setting and unsetting the system Please refer to the Using G Tag section for instructions Setting amp Unsetting the System via a Keyswitch if fitted eur sec CPX lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 EXIT Now All Zones ON 15 Time will count down One of two types of keyswitch es may have been fitted to your system Normal To set the system with a normal keyswitch insert the key and turn to the ON position then remove the key Follow the instructions from step 3 above To unset insert the key and turn to the OFF position Biased To set the system with a biased keyswitch insert the key and turn it then return the key to the original position and remove Follow the instructions from step 3 above To unset repeat this operation
12. 2 or 3 Set the system To Part 1 Set your security system press Yes twice the display will show Press CODE to Part Set Present your Tag to the Proximity Reader and exit the protected area following the normal Part Setting You System Instructions Page 24 eur sec CPX User Manual Display Status Blanking It may be a requirement that the Status Set or Unset display of the security system is not displayed If this option has been invoked by your installation company the Set or Unset Status will only be displayed for ten seconds when the system is Set or Unset The top line of the display will then be blanked off You may check the Status of the system at any time by pressing the Yes key and then entering a valid User Code If the system was Set when you did this the display will ask if you wish Unset the system To do so press Yes within ten seconds If the system was Unset when you did this the display will ask if you wish Set the system To do so press Yes within ten seconds If you do not choose to Set or Unset the system within the ten seconds the top line of the display will be blanked out and the code entry will be invalidated Keypad Tamper The keypad will monitor the number keys that are pressed without a valid User Code being entered More than 24 key presses will cause a keypad tamper This will be displayed as Keypad x Tamper and will require a valid User Code entry to stop the
13. be programmed to On within the Programming User Codes section Typical Alarm Message Site 05 Alarm Zone 06 This would indicate an alarm at Site ID 5 has occurred on Zone 6 Page 19 User Manual User Initiating Remote Access Optional eur sec CPX Access Remote allows your installation company to examine your system and re program system settings as you need the changes without the need for an engineer to visit your premises If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call usually on lines with incoming calls barred To initiate the Remote Call follow the instructions below 1 Note Negotiate with your installation company when you should initiate the Remote Call With the display showing Enter a Master Code the display will show Press NO seven times the display will show Press YES the display will show Until Dialling commences Then Until Connection Then When your installation company has finished the display will show In the event of any errors the display will show Check line is not in use or disconnected etc Page 20 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you wantto Set NAOMI Do you wantto Access Remote Please WAIT Please WAIT Dialling
14. or engineer as instructed by the installation company and guote the source given by the display The central station or engineer will give a return Anti Code this may contain the YES 8 NO keys for example 5 YES 2 4 Enter this Anti Code into the keypad The system is now reset Page 22 eur sec CPX eur sec CPX Duress Codes Using a Duress Code is a method of sending a Personal Attack signal to your central station The CPX is capable of using two methods to activate the Duress signal Method 1 See Note Any code programmed as User 7 will act as a Duress code Setting or Unsetting the system using the code that is programmed as User 7 will activate a Duress signal Method 2 See Note 1 Add 1 to the first digit of any user code for example if your User code is 5678 the Duress for this code would be 6678 In this instance using 6678 will send a Duress code to your central station when you Set or Unset your system Note 1 Duress option s must be turned on by your installation company Note Care must be taken with Duress codes misuse of Duress codes may lead to the loss of police response Note Local legislation may prevent the use of Duress signals Page 23 eur sec CPX eur sec CPX G Tag Introduction G Tag is a method of Setting and Unsetting your security system via a Proximity Reader and a Tag The Proximity Reader may be built in to the keypad or be an external reader that is fitted into a
15. sounders If the system was Unset only the internal sounders will operate If the system was Set a full alarm will be generated System Tampers The full security system is tampered any attempt to remove covers from Keypads Control Panel Keypads Bell Box es or detectors will cause a tamper alarm This also applies to cut cables If the system is Unset when the Tamper occurs the alarm will be internal sounders only If the system is Set a full alarm will be generated The alarm may be silenced by entering a valid User Code The system may only be Reset when the Tamper has been cleared otherwise another Tamper alarm will be generated Page 25 User Manual eur sec CPX Mains Failure In the event of a Mains Power Failure the display will show Power Cut FAULT I Check At this point the system will revert to battery back up The battery will only have a limited time that it can sustane the system for Note Your installation company will have determined what size battery is required to comply with legislation It is important that your security system is serviced on a regular basis on order that it continues to comply with the legislation Servicing may also be a requirement of you insurance policy The display will clear once the power is restored In the event of a sustained power cut the system battery will continue to supply the system until the battery voltage falls to a set point
16. 112 as the telephone numbers that the Vo Comm will dial Before Vo Comm can work several options will need to be programmed please read below for information Vo Comm Programming if fitted 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 Jan 00 00 01 2 Enter a valid Master Level Code 5678 default Display will show Do you want to Set the System 3 Press No 7 times Do you want to Display will show Set Up VoComm 4 Press Yes 3 f VoComm Display will show Off 5 Press No until display will shows VoComm gt On 6 Press Yes Display will show VoComm Tel No 1 Is Un Programmed Or for example VoComm Tel No 1 12345678910 7 To enter or change this number Press No Display will show VoComm Tel No 1 Page 16 eur sec CPX 8 10 11 12 13 14 15 16 17 18 Enter the telephone number you require followed by Yes Display will show To enter or change the number repeat from step 7 Display will show To enter or change the number repeat from step 7 Display will show To enter or change the number repeat from step 7 Display will show Press No twice Display will show Enter a unique Site ID for the premises 00 to 99 followed by Yes This Site ID will identify what system is calling you Disp
17. additional or new staff training should be directed to your installation company User Code Types Five Levels of User Codes are available on the eur sec CPX each user code type allows for different levels of access In total 15 User codes may be programmed by a Master Level User Code User number 1 will always be a Master Level User but the remaining 14 User Codes may be programmed by a Master Code to the required level of access These may be changed at any time via a Master level code The User Code levels available and the functions available for the levels are Master Allows Setting Unsetting Zone Remove if programmed by User 1 will always engineer Test System View Log Chime On Off User be Master Level Codes Set Time Date Reset After Alarm if programmed by engineer Unsetting Control Allows an output that has been pre programmed by the installation company to be operated May have the attribute of Can Cant Unset May never Set a system Refer to Advanced Code Programming for details Set Only Only Allows for the setting of the system Main User Allows Setting Part Setting Zone Remove if programmed by engineer System Test Unsetting Reset after Alarm if programmed by engineer User Allows Setting Part Setting Reset after Alarm if programmed by engineer Unsetting Note Duress Codes may also be used on this system for activating Personal Alarms P A For information on using Duress on the eur
18. at his stage the display will show Fuse Bat FAULT I Check A fault sounder will start enter a valid User Code to stop the fault sounder At this point it is essential that you contact your installation company Page 26 eur sec CPX User Manual Advanced Code Programming This section cover the programming and use of Advanced Codes The Code Level of Control is classed as an Advanced Code Several parameters will need to be programmed by the installation company before a Control Code may be programmed into the system You should also note that a Code Level of Control may never Set the system Typically a Control Code would be used for turning on an output or act as a limited door access system In order for this to function additional hardware would be required To program a Control Code level Follow the normal instructions for programming codes At the Point when you are asked for the Level choose Control When asked for the Code Group enter 1 to 8 your installation company will have given you what group to use Then choose Can or Cant Unset dependant on your requirements Follow the normal instructions to the end for programming codes Using Advanced Codes Two typical uses for Advanced Codes are 1 To turn on an output e g a light Enter the User Code or present your Tag the output will turn On Enter the User Code or present your Tag again the output will turn Off 2 To op
19. doorframe etc Legislation contained within DD243 does not allow for the transmission of confirmed alarm signals once the entry time has started if the user of the security system is using a manual code entered into the keypad G Tag conforms fully with the requirements of this legislation relating to confirmed alarms on G TagFob entry Because the G Tag uses Proximity Technology there are no batteries to change in the unit it is small enough to be carried on the users key ring and one Tag may be used on multiple security systems and some door entry systems Programming G Tag Tags Onto Your System Programming The Tags onto your system is very simple Follow the instructions for programming User Codes onto your system up to the point when you would enter the User Code At this point present you Tag to the Proximity Reader and a code will be entered for you Continue with the instructions entering the User Name etc Each G Tag will be identified on an individual basis when it is used to Set or Unset the system Using G Tag On Your System G Tag is a method of entering a code into your security system To Set Your System Using G Tag When you wish to Set your system simply present your Tag to the Proximity Reader and exit the protected area following the normal Setting You System Instructions To Part 1 Set Your System Using G Tag If using G Tag Part 2 and Part 3 Setting will not be available a manual code should be used to Part
20. en a door e g door access with limited function Enter the User Code or present Tag to external Tag reader door will release for the time period determined by your installation company Page 27 User Manual eur sec CPX System Attributes Control Panel Zones Zone No Zone Type Descriptors Part Info Example 182 Radio Zones If Fitted Zone No Zone Type Descriptors Part Info Page 28 eur sec CPX User Manual Service Record Date Comments Signature Alarm Reset Type Tamper Reset Type Page 29 eur sec CPX eur sec CPX User Chart Please use this chart to indicate what user names have been programmed onto your system and those that are in use Code G Tag User Name User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 User 10 User 11 User 12 User 13 User 14 User 15 Note Under no circumstances should you write down the actual code Radio Fob Users If Used User Name User 81 User 82 User 83 User 84 User 85 User 86 User 87 User 88 Use this space to record any codes that have been reserved for Keyswitch es Duress Code On off Duress Code Method User 7 Duress Add 1 to first digit of code Page 30 eur sec CPX User Manual Page 31 User Manual eur sec CPX Page 32 eur sec CPX User Manual Page 33 eur sec CPX User Manual Page 34 i 0 BSIA THE BRITISH SECURITY TRY ASSOCIATION OF 1 nN PR5598 Rev1 1
21. he display will show Press Yes to accept and the go to step 8 OR Press No display will show Enter the Year then press Yes Display will show Press Yes Display will show Enter the Day Month ie 0706 for 7th June followed by YES The display will show Enter the time using 24Hr Clock ie 23 30 for 11 30pm followed by YES the display will show Press 0 the display will show Page 15 User Manual lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you wantto Set NAOMI Do you want to Set DATE TIME Summer Adjust is On ok gt Year is 2005 ok Enter Year 20 Then YES Year is 2005 ok Enter Day Month Then YES Enter Hrs Mins Then YES Do you wantto Set DATE TIME lt lt lt lt UN SET gt gt gt gt 07 Jun 23 30 02 User Manual eur sec CPX Vo Comm if fitted Vo Comm is a method of transmitting signals to a standard land line or mobile telephone giving information regarding the status of your security system This may be in addition to or instead of central station communications It should be noted that Vo Comm should not under any circumstances be used to ring the Emergency Services directly It will not be possible to program 999 911 or
22. lay will show To change this press No until the required setting On or Off is displayed then press Yes The term Open relates to the system being Unset With Open Reporting turned on the Vo Comm will report the system being opened Unset for all users who have had the attribute of Vo Comm Trigger On allocated in the User Code Programming Page 17 User Manual VoComm Tel No 2 is Un Programmed VoComm Tel No 3 is Un Programmed VoComm Tel No 4 is Un Programmed Site ID 00 Site ID Open Reporting On User Manual eur sec CPX 19 20 21 22 The display will show Close Reporting gt Off The term Close relates to the system being Set With Close Reporting set to anything other then off the Vo Comm will report the system being closed Set for all users who have had the attribute of Vo Comm Trigger On allocated in the User Code Programming Options available are Off No system Close are reported Full Set Only Full Sets are reported Any Set All Sets Full amp Part are reported Press No until your required setting is shown then press Yes Display will show Make an Alarm Test Call Press No this is dealt with in the using Vo Comm section The display will show Do you want to Set Up VoComm
23. ne has been audible or a single beep will be emitted if the exit tone has been silent The system is now Part Set you are free to move around the zones that have been removed by the Part Set but other zones on the system are active Page 6 eur sec CPX User Manual Removing Zones When Setting Master amp Main codes only If programmed by the installation company individual zones may be removed omitted when the system is set this may only be done by a Master or Main level of code 1 Note With the display showing Enter a Master or Main level code the display will show Press NO the display will show Press YES the display will show Enter the zone number you wish to remove followed by YES pressing NO will un remove a zone the display will show Repeat step 5 until you have removed all the reguired zones Press 0 to escape the display will show Press YES the continuous exit tone will sound Exit the premises via the authorised exit route the exit tone will change as detectors are violated When the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Zone remove is only effective for the one set Page 7 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Set NAOMI Do you want to Do you want to REMOVE Zones Enter Zone No
24. omm section in this manual Press Yes The display will show User 1 Name If you wish to accept the name shown press NAOMI Yes and jump to step 13 Or If you wish to change the name shown press No the display will show User 1 Name gt You may now enter up to nine characters for the user name using the layout shown on the following page for the allocation of characters Page 13 User Manual eur sec CPX STU VWX YZ 0 9 Sd 0 ee eo ee ee fn J 12 Referring to the character map enter the required character pressing the 3 key will display G pressing it again will show H and again will show I once the correct character is displayed press Yes and the display will move on to the next position 13 Continue entering characters up to 9 If you require a blank space press YES while the is displayed 14 As you press YES for the ninth character or if you have jumped from step 9 the display will change to Do you wantto Prog USER CODES 15 If you wish to program other User Codes return to step 4 Or Press 0 to return to lt lt lt lt UNSET gt gt gt gt 01 JAN 18 58 01 Page 14 eur sec CPX Programming Time amp Date 1 With the display showing Enter a Master Code the display will show Press No six times the display will show Press Yes the display will show Press Yes t