Home
User`s Manual Sound Level Alert Model SL130
Contents
1. 2 3 Alarm Alert Switch LED response Switch Red 1 LED s flash red while dB level exceeds set point LED s flash red while dB level exceeds set point High Red Green 2 40 second green indication when level transitions from ALARM high to low Green 3 40 second green indication when level transitions from high to low Green 3 LED s are green while dB level is below set point LED s are green while dB level is below set point Low Red Green 2 40 second flashing red indication when level ALARM transitions from low to high Red 3 40 second flashing red indication when level transitions from low to high 5 Version 3 2 8 07 MAX Hold The MAX display indicates and holds the highest dB level measured a since the meter was turned on or since the Max Reset button was pressed The time and date of the max reading is also displayed oA d TB To clear the display and start a new measurement session press the Wg PM Sue front panel MAX RESET button If the measured level exceeds the et maximum for the range selected the MAX display will indicate OL overload Programmable OFF ON AUTO time The meter is powered by 8 AA batteries or via an AC adaptor for permanent installations Continuous battery life is approximately 240 hours 10 days By programming the ON OFF time the battery life can be greatly extended 30 days assuming an 8 hour day The ION and Jj times are programmed as described in the initial
2. The bright LED s are functional only when the AC power adaptor is used Careful use of this meter will provide years of reliable service Specifications Applicable standards Meets IEC 60651 1979 and ANSI S1 4 1983 Type 2 SLM standards Display 11 7 x 7 94cm 4 6 x 3 125 multifunction LCD Frequency bandwidth 31 5 Hz to 8 KHz Microphone 0 5 Electret Condensor Microphone remoteable Measurement ranges 30 to 80dB 60 to 110dB 80 to 130dB Frequency weighting A and C Response time Fast 125ms Slow 1s Resolution 0 1dB Max Hold Maximum reading is displayed with time stamp Alarm output 3 5mm Mono Phone Plug 3 4mA 5 Vdc typical Limit range 30 to 130dB Under range indication Over range indication OL Power Battery life AC adaptor 9V 500ma or 8 AA batteries 240hrs continuous approx 30 days 8hrs day LED s are not functional when battery powered Operating temperature 0 to 50 C 32 to 122 F Operating humidity Less than 80 RH Dimensions Weight 22x18x3 2cm 285g 8 75x7 1x1 25 0 63 lbs 2 Version 3 2 8 07 Meter Description a OD ONOa PF OM 0 Microphone 1 Over Limit Display Bargraph dB display 2 7 OFF ON AUTO switch Alert LEDs E OVER kadi 7 Clock display 3 03 Os 8 Max level display with time stamp 4 al alB Lim Set
3. displayed If the measured dB level is below the selected range will be displayed Normally select the range in which the upper dB level is greater than any expected sound pressure level The 60 to 110dB range is the most commonly used range Use the 30 to 80dB range in quieter areas such as offices and classrooms Note When the range is changed the Max display may indicate an overload OL Press the MAX RESET button to clear the MAX display High Limit Set Press the up or down LIMIT arrow buttons to set the High Low limit LI M IT set point as displayed on the LCD If the measured dB level LIMIT cn exceeds the set limit the J indication will appear in the display rs 15 0 dB and the over limit signal will appear at the alarm output connector The display indication and output signal will remain active as long as the sound pressure level exceeds the set limit High Low LED Alert The four LEDs are used to alert users when a sound level either exceeds or goes below the Limit set point This feature is available only while the AC adaptor is used to power the meter It is disabled under battery power The LEDs will provide a steady or flashing colored indication depending on the setting of the side panel ALARM and Alert switch settings The three Alert switch positions are 1 RED 2 RED GREEN 3 GREEN
4. limit MAX RESET button 5 fc 10 Rear Control Panel Daar Nn Side Panel 1 2 3 4 5 6 Range select switch Time set buttons 1 2 4 6 Limit set buttons 7 Calibration adjustment ge ser 2 olo i Ap A C select button F S select button Alert switch Green position Alert switch Red Green position Alert switch Red position High Low Alarm switch Remote Alarm output connector AC adaptor connector Rear Panel 1 2 3 4 5 Tilt stand Battery compartment AC Adaptor connector Remote Alarm output connector Windscreen 3 Version 3 2 8 07 Sound Level Monitor Operation Measurement Considerations Use a windscreen to cover the microphone in windy conditions Calibrate the meter often especially if the meter has been idle for a long period of time Do not store operate the meter in areas of high temperature or humidity Keep the meter and the microphone dry gi gA GaN se Avoid severe vibration when using the meter 6 Remove the battery when the meter will be stored for long periods of time Initial Configuration 1 Connect the AC adaptor to the side or rear AC adaptor connector OR Install 8 AA batteries 2 Setting the TIME a Press and Hold the Time SET button until the hours display begins to flash ser 2 b Press the Time up arrow button until the hour is set c Press the SET button The minutes display will flash Adjust as needed d P
5. proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Copyright 2006 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form 8 Version 3 2 8 07
6. User s Manual EXTECH INSTRUMENTS Sound Level Alert Model SL130 OVER 3 58 330 MAX 1 921 4 70 3 15 z dB LIMIT A S 75 08 INSTRUMENTS Sound Level Alert SL130 Meets ANSI and IEC Type 2 Sound Level Meter Standards Settable High Limit with large bright High Low indication and Alarm Output Wall or Desk mountable Extra large LCD display with bargraph C Maximum level display with time stamp VV VV V WV Optional alarm kit drives remote over limit indicators Introduction Congratulations on your purchase of the Extech SL130 Sound Level Alert Designed for wall mount desk tripod mount or hand held operation this meter meets ANSI and IEC Type 2 Sound Level Meter standards Included is a High Low Limit Set Point with 4 two color high intensity LED limit exceed indicators and a large OVER indication when the set level is exceeded An Alarm Output can be used in conjunction with the optional Alarm Module Kit to power a larger or a remote indicating device such as a QUIET sign Professional features include programmable A C Weighting and Fast Slow Response time Max Memory with time stamp and a Clock display The microphone can be rotated 180 degrees to accommodate any meter location or it can be placed at a remote location using the optional Remote Microphone Cable A programmable ON OFF time extends battery life to 30 days when programmed 8 hours per day
7. configuration paragraph The meter will operate continuously with the power switch in OFF atten AUTO the ON position The ON OFF time will be controlled by the meter when the power switch is set to the AUTO position Calibration The sound level meter should be calibrated on a regular basis to assure that the meter s performance and microphone sensitivity has not change Some operational directives require daily calibration checks OSHA Extech offers several acoustic calibrators to perform the calibration 1 Set the meter to the 60 to 110dB or 80 to 130dB range 2 Place the external calibrator over the Sound Level Monitor s microphone and turn the Calibrator on 3 The meter should read close to the calibrator s dB output level Typical Calibrator output levels are 94dB and 114dB 4 Ifthe meter is within 0 2 dB of the calibrator s output no adjustment is necessary 5 Adjust the calibration pot on the rear of the meter to the proper level Meter Placement The meter can be used Handheld Wall mounted Desk mounted or Tripod mounted For wall mount operation orient the microphone perpendicular to the wall to minimize the affect of acoustic reflections For desk mounting extend the rear legs and lock in place with the hinged locks The tripod mounting nut is located on the bottom of the unit l i 6 Version 3 2 8 07 Remote Micr
8. ophone optional The optional 15 remote microphone cable can be used to place the microphone in one location while viewing the dB levels and or generating a high limit alarm at another location To remove the microphone unscrew the holding collar and lift the microphone off the connector The extension cable can then be plugged into the matching connectors Calibration should be performed after the cable is installed MAX 53 5 92 18 4IO 3 15 1 B uM 60 AS 15 08 a E E E Alarm Output optional The alarm output drives the optional Remote Alarm Relay Module cable and relay when the LIMIT set point is exceeded The relay module can be used to power external warning signs QUIET signs or other indicating devices when the sound level is higher than the programmed limit Refer to the manual supplied with the module for connection information HEARING PROTECTION Relay Module REQUIRED Indicating Device T Version 3 2 8 07 Battery Replacement AC power is the normal power source for this meter If 8 AA batteries are used they are located in the rear battery compartment When the battery icon appears on the meter s LCD it is time to replace the batteries 1 Turn power off 2 Open the rear battery cover 3 Insert the batteries into battery holder observing the correct
9. polarity 4 Put the battery cover back in place Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell For periodic calibration NIST certification or repair of any Extech product call customer service for details on services available Extech recommends that calibration be performed on an annual basis to insure calibration integrity ry Support line 781 890 7440 Technical support Extension 200 E mail support extech com Repair amp Returns Extension 210 E mail repair extech com Product specifications subject to change without notice For the latest version of this User s Guide Software updates and other up to the minute product information visit our website www extech com Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and
10. ress the SET button to step through and the arrow button to adjust Time of day Hour Time of day Minutes Time of day AM PM 24 Hour Year Month Day Auto ON Hour Auto ON Minutes Auto OFF Hour Auto OFF Minute A C Frequency Weighting Change the Frequency Weighting by pressing the Q A C button The A or C icon will appear on the display With A weighting selected the frequency response of the meter is similar to the response of the human ear A weighting is commonly used for environmental or hearing conservation programs such as OSHA regulatory testing and noise ordinance law enforcement C weighting is a much flatter response and is suitable for the sound level analysis of machines engines etc Most noise measurements are performed using A Weighting and SLOW Response Slow Fast Response Press the button to select Fast or Slow response as desired F or S will appear in the bottom of the LCD display Select FAST to capture noise peaks and noises that occur very quickly Select the SLOW response to monitor a sound source that has a consistent noise level or to average quickly changing levels Select Slow response for most applications 4 Version 3 2 8 07 Range Selection Slide the Range switch to the 30 80 60 110 or the 80 130 position 49 80 80 130 The selected range will be indicated on the LCD bargraph If the Bng measured dB level exceeds the range selected OL will be 60 110
Download Pdf Manuals
Related Search
Related Contents
MOTO 4 PRO TECH 5W40 Insys Modem 56k 4.1 m/UL Fiche technique du produit Istruzioni per l`uso I P99 AS P99 QA P99 DAO Full Size dossier reçu le 20/12/2013 Samsung UD46A Benutzerhandbuch manual - Thomann Druck DPI 104-IS - GE Measurement & Control AVC Multimedia - Prime Time Manufacturing Copyright © All rights reserved.