1.      CAUTION  Illumination is intense     CAUTION  Use only the cleaning methods and disinfection solutions methods  described in this manual  Clean the device prior to disinfection     CAUTION  The Illuminator  REF 78800  is a biohazard after use  Follow good  hospital practices and the instructions for cleaning and disinfection of the  illuminator within this manual prior to the next usage     CAUTION  Ensure lamp is installed and fully seated in illuminator throughout  cleaning and disinfection process  The illuminator assembly is immersible   IPX7  provided the lamp is properly installed     CAUTION  This device complies with current required standards for  electromagnetic interference  and should not present problems to other  equipment or be affected by other devices  As a precaution  avoid using this  device in close proximity to other equipment     U S  Federal Law restricts this device to sale by or on the order of a physician     To remove all power from the Vaginal Illumination System  unplug the external  power supply from the wall outlet     Illuminator is capable of temporary immersion to a depth of 0 15 to 1 meter   at ambient pressure  at room and fluid temperatures of 22  C to 43  C     There are no user serviceable parts inside the device except the lamp   Contact the Authorized Service Center listed on page 13     Consignes de s  curit   et precautions        gt   gt     gt   gt  gt  gt   gt   gt   gt   gt     MISE EN GARDE   Pour   viter les blessures ocul
2.    A     WelchAllyn    KleenSpec  Vaginal Specula Illumination    System  REF 78810                        Table of Contents    Classification                               1  Symbol Descriptions 22 perpe S 33 bc YI YJ 1  Warnings and Cautions                       2  Consignes de s  curit   et pr  cautions            3  Instructions for USe su coat ei neh ee re 4    KleenSpec Vaginal Specula Illumination System     4    MIAINTENANGE    adum scire ue Bare pp er D  Preventative Maintenance                      5   Lamp Replacement                           5  Cleaning Disinfection  and Sterilization             6  SIC  m 6   DISINFECTION  mermas d enm ba l     butcher ata 7   SIELIZALION k  lan   Kn ka en Mee k   ss tete 8   DI SDOSA  Saai R dk wo e a eee ees dS 8  opecifications     2  Han 9  PAS  IRON OR 10  Troubleshooting Guide                      11  Troubleshooting Guide   Oualified Personnel Only   12  Warranty and Service                       13  Limited Warranty   esci kk kk a aed e E ERU d T3  Technical Assistance                         14    Welch Allyn Service Centers                   15    Thank you for purchasing the Welch Allyn 78810 KleenSpec9 Vaginal Specula Illu   mination System composing of the 78800 illuminator and the 73410 transformer   Please review this manual prior to using this system  This updated system  replaces the current Welch Allyn 78010 KleenSpec Vaginal Specula Illumination  System composed of the 78000 illuminator and the 73305 transfor
3.   Cleaning Limited Soak    or    Cleaning   Wipe       2  Follow the disinfecting wipe manufacturer s disinfection instructions on the  cord only     3  Thoroughly rinse the cord only with 22  C to 43   C tap water to remove  disinfectant   4  Allow to dry     Sterilization   Refer to the Cleaning Table to identify the appropriate sterilization method prod   uct for the expendable illuminator    Wet Steam Autoclave   Expendable Illuminator  REF 78600     1  Clean expendable illuminator as instructed in    Cleaning Soak      2  Place the expendable illuminator in the autoclave chamber to allow best  exposure to steam  Autoclave chamber parameters are as follows     e Type  132   Pre vacuum  Hi VAC  Steam Cycle  e Exposure Temperature  132  C to 135  C  270  F to 275  F   e Exposure Time  3 5 minutes  e Exhaust Time  Fast  Disposal    There are no harmful materials associated with the Illumination System     Device is considered a biohazard after use  Follow good hospital practices and  local ordinances in the disposal of the illuminator     There are no risks associated with the disposal of this device after its useful life if  it is cleaned and or disinfected per the instructions in this manual     Specifications   Classification  REF 73410   Input    Output   Category    Physical Specifications   Illuminator   Transformer    Illumination    Lamp Life   Lamp Voltage   Lamp    IPX Rating    Illuminator   Transformer     Environment  Operating     Transport Storage     Intermit
4.  78600     Refer to Cleaning Table to identify the appropriate cleaning product     1  Disconnect the transformer from the wall outlet and then disconnect the  illuminator from the transformer   2  Disconnect illuminator from expendable illuminator and remove the    expendable illuminator from the speculum  58600 58601 only      Lamp must remain installed during all cleaning and disinfection   gt  processes     3  Follow the disinfecting wipe manufacturer s instruction and wipe cord   illuminator  or expendable illuminator completely to remove any residue    4  This process is a rough clean only  Refer to disinfection or sterilization for  further processing     Soak  Refer to Cleaning Table to identify the appropriate cleaning product     Illuminator  REF 78800  and or Expendable Illuminator  REF 78600     1  Disconnect the transformer from the wall outlet and then disconnect the  illuminator from the transformer     2  Disconnect illuminator from expendable illuminator and remove the  expendable illuminator from the speculum  58600   58601 only      Lamp must remain installed during all cleaning and disinfection    gt  processes     3  Follow the cleaning solution manufacturer s instructions and soak the  illuminator and or expendable illuminator as instructed  Solution temperature  is 22   C to 43  C    4  Scrub any area of visible debris with a soft brush and thoroughly rinse the   illuminator and or expendable illuminator with 22  C to 43  C tap water to   remove the cle
5.  manufacture of  the component s    e llluminator  Four digits  month then year  stamped inverted and to the  right of  REF 78800  near the lamp   e Transformer  Four digits  month then year stamped or labeled on the  prong side of the transformer plug     If you are advised to return a product to Welch Allyn for repair or routine  maintenance  schedule the repair with the service center nearest you     Before returning a product for repair you must obtain authorization from Welch  Allyn  Return Authorization number will be given to you by our service personnel   Be sure to note this number on the outside of your shipping box  Returns without  a return authorization number will not be accepted for service  Prior to  shipment  please clean and disinfect the component as instructed in this  manual     13    Welch Allyn       4341 State Street Road   Skaneateles Falls  NY 13153   Tel   800  535 6663 or  315  685 4560  Fax   815  685 3361  www welchallyn com    Part No  718911 Rev  A Printed in the U S A     
6.  the purchaser s risk     Welch Allyn will not be responsible for loss associated with the use of any Welch  Allyn product that  1  has had the date of manufacture number defaced   2  has  been repaired by anyone other than an authorized Welch Allyn Service  Representative   3  has been altered   4  has been used in a manner other than in  accordance with the instructions  or  b  has been abused or exposed to extreme  environmental conditions     THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY IMPLIED WARRANTY  OR MERCHANTABILITY  FITNESS FOR PARTICULAR PURPOSE  OR OTHER  WARRANTY OF QUALITY  WHETHER EXPRESSED OR IMPLIED  WELCH ALLYN  WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES  RESULTING FROM THE SALE  USE  OR IMPROPER FUNCTIONING OF THE  INSTRUMENTATION REGARDLESS OF THE CAUSE  THE DAMAGES FOR  WHICH WELCH ALLYN WILL BE RESPONSIBLE INCLUDE  BUT ARE NOT  LIMITED TO  LOSS OF REVENUE OR PROFIT  DOWNTIME COSTS  AND LOSS  OF USE OF THE INSTRUMENTATION     Technical Assistance   If you have an equipment problem that you cannot resolve  you may call the  Welch Allyn Service Center nearest you for assistance  For Technical Support or  to obtain information about any Welch Allyn product  contact Welch Allyn  Technical Support   www welchallyn com support    or visit www welchallyn com about company locations htm    Prior to contacting Welch Allyn or its service center  please refer to the following  areas of the illuminator and or transformer to identify the date of
7. 05  59006  and 58600   58601  with expendable illuminator  78600  for gynecological and obstetric procedures     The transformer plug  REF 73410  provides power from the hospital grade wall  outlet to the illuminator assembly  REF 78800  which houses the lamp  REF  08800   This provides illumination to the specula and expendable illuminator  see  above   This device is intended for use only with appropriate accessories  see  above      This product is for use with the Welch Allyn KleenSpec Single Use Vaginal  Specula only  Do not use the illuminator for any other use  Lamp is hot and can  cause a burn if used outside of the vaginal specula     Assemble the transformer to the illuminator as shown below  The illuminator then  slides into the appropriate Welch Allyn accessory listed above  Verify all  connections are made prior to applying power with the on off switch                     pecula  see above     Push down to increase  angulation     Push down to we N      elevation   g Y   A Specula  see   REF 78600 2 pecula      Transformer Plug    Erin nn nn nn            s           Push up to  increase    22    X a elevation  REF 73410  REF 08800  On Off Switch a SY  Energizes the lamp  A  LA SP te             HIT         nn  n n            System             REF 78800 P       Maintenance    Preventative Maintenance  Monthly examine cords  connections  and transformer case for wear or damage     After every use  clean the unit according to the Cleaning  Disinfection  and  Steri
8. ION   S assurer que la lampe est bien install  e et mont  e dans  l illuminateur pendant toute la dur  e de la proc  dure de nettoyage et de  d  sinfection  Le syst  me illuminateur peut   tre immerg    IPX7     condition que la  lampe soit correctement mont  e     ATTENTION   L instrument satisfait aux normes actuelles en vigueur concernant les  interf  rences   lectromagn  tiques et ne devrait ni affecter ni   tre affect   par les  autres appareils  Par mesure de pr  caution    viter d utiliser cet instrument tout  pr  s d un autre appareil    La loi f  d  rale des   tats Unis limite la vente de cet instrument    un m  decin ou sur  ordonnance d un m  decin    Pour   teindre compl  tement l illuminateur vaginal  d  brancher l alimentation  ext  rieure de la prise murale    L illuminateur peut   tre plong   temporairement    une profondeur variant entre 0 15  et 1 m  tre    la pression atmosph  rique     une temp  rature ambiante et du liquide  d immersion comprise entre 22  C et 43  C    Mis    part la lampe  cet instrument ne poss  de aucun composant que l utilisateur  ait    entretenir  Contacter le centre de service agr     indiqu   sur la page 13     Instructions for Use    KleenSpec Vaginal Specula Illumination System    The KleenSpec Vaginal Specula Illumination System  REF 78810   consisting of  the illuminator  REF 78800  and transformer  REF 73410  are designed to work  with the following Welch Allyn specula  580005  58001S  580045  590XS  59000   59001  59004  590
9. aires  ne pas regarder dans le  rayon     MISE EN GARDE   La lampe est nocive au toucher pour la peau  Laisser la lampe  refroidir pendant 5 minutes avant de la remplacer  La lampe g  n  re beaucoup de  chaleur et doit rester   teinte jusque juste avant et imm  diatement apr  s utilisation   Ne pas placer l illuminateur sur une surface inflammable si la lampe est allum  e     MISE EN GARDE   D  brancher le transformateur de la prise murale avant toute  maintenance     MISE EN GARDE   L usage de cet instrument est strictement limit   aux sp  culums  vaginaux Welch Allyn KleenSpec     usage unique  Ne pas utiliser l illuminateur a  toute autre fin  La lampe est chaude et peut causer des br  lures si elle est utilis  e  sortie du sp  culum vaginal     MISE EN GARDE   L illuminateur pour sp  culums vaginaux KleenSpec  ne peut   tre  utilis   en pr  sence d un m  lange anesth  sique inflammable gazeux    base d air   d oxyg  ne ou d oxyde nitreux  Une explosion pourrait se produire     ATTENTION   Utiliser seulement les m  thodes de nettoyage et les solutions et  m  thodes de d  sinfection d  crites dans ce manuel  Nettoyer l instrument avant de  le d  sinfecter     ATTENTION   L   clairage est intense     ATTENTION   L illuminateur  REF 78800  repr  sente un danger biologique apr  s  utilisation  Appliquer les bonnes pratiques hospitali  res et respecter les consignes  de nettoyage et de d  sinfection de l illuminateur explicit  es dans ce manuel avant  l usage suivant     ATTENT
10. aning solution    Rough dry the illuminator and or expendable illuminator    The illuminator and or the expendable illuminator is now ready for   disinfection     Limited Soak  Transformer  REF 73405 or REF 73410     Refer to Cleaning Table to identify the appropriate cleaning product    1  Disconnect the transformer from the wall outlet and then disconnect the  illuminator from the transformer    2  Follow the cleaning solution manufacturer s instructions and soak the cord  only in the solution as instructed  Solution temperature is 22  C to 43  C    3  Scrub any area of visible debris with a soft brush and thoroughly rinse  transformer cord only with 22  C to 43   C tap water to remove the cleaning  solution    4  Rough dry transformer    5  The transformer is now ready for disinfection     Oo    Disinfection  Refer to the Cleaning Table to identify the appropriate disinfection method prod   uct for the illuminator  expendable illuminator  and or transformer     Illuminator  REF 78800  and or Expendable Illuminator  REF 78600    1  Clean illuminator and or expendable illuminator as instructed in    Cleaning   Soak    or    Cleaning Wipe       2  Follow the disinfecting wipe manufacturer s disinfection instructions    3  Thoroughly rinse illuminator and or expendable illuminator with 22   C to 43    C tap water to remove disinfectant    4  Allow to dry     Transformer  REF 73405 or REF 73410    DO NOT IMMERSE THE TRANSFORMER PLUG    1  Clean transformer as instructed under  
11. ct and socket threads   Verity voltage reads approximately  4 6 volts  DC with REF 73405 or  AC with REF 73410   Only properly  trained personnel shall perform  this test     Lamp does not  light     Verify the voltage supplied to the  transtormer outlet meets the  requirements stated in this  manual     Improper voltage  supplied to the  transformer     Light output  seems low     This guide is intended to provide assistance towards determining the fault  condition of this product  Please contact the authorized Welch Allyn Service  Center listed within the product owners manual for additional assistance        Warranty and Service  Limited Warranty    Instrumentation purchased new from Welch Allyn  Inc   Welch Allyn  is warranted  to be free from original defects in material and workmanship under normal use  and service for a period of one year for Welch Allyn KleenSpec Vaginal Specula  Illumination System  REF 78810   comprised of the illuminator  REF 78800  and  the transformer  REF 73410  from the date of first shipment from Welch Allyn   This warranty shall be fulfilled by Welch Allyn or its authorized representative  repairing or replacing at Welch Allyn s discretion  any such defect  free of charge  for parts and labor     Welch Allyn must be notified via telephone of any defective product and the item  must be immediately returned  with an RMA number provided by Welch Allyn   securely packaged and postage prepaid to Welch Allyn  Loss or damage in  shipment shall be at
12. lization section of this manual     Lamp Replacement    A    The lamp is the only user serviceable part on the Illumination   gt  System  Replace the lamp when there is insufficient illumination        CCW       1  Disconnect the transformer from the wall outlet and then disconnect the  illuminator from the transformer    2  Allow lamp to cool for a minimum of 5 minutes and remove the lamp by  unscrewing counterclockwise  CCW     3  Inspect the lamp socket of the illuminator for damage or irregularities    Contact the authorized Service Center if any irregularities are found    Replace with Welch Allyn REF 08800 lamp only    Verify that the lamp o ring is present and free from damage or debris prior to   installation  If o ring is missing or damaged  replace the lamp    6  Install by screwing clockwise  CW      pus    Cleaning Disinfection  and Sterilization    Transformer   Expendable  REF 73405 or   Illuminator  REF 73410 REF 78600    CaviWipe  Metrizyme le    Limited  Yes  Caviwipe Intermediate   Intermediate  Level  Level Level      Do not immerse the transformer plug  Follow instructions per this manual      The Expendable llluminator s ability to transmit light will degrade after  repeated autoclave cycles  approximately 20  and will eventually need  replacement           Illuminator  REF 78800                    isi   Intermedi  Disinfection termediate          Cleaning   Wipe   Transformer  REF 73405 or REF 73410   Illuminator  REF 78800   Expendable  Illuminator  REF
13. mer     Classification  Class Il  Type BF Applied Part Ordinary Equipment  Sterilize only as directed in Cleaning Section Non continuous Operation    Symbol Descriptions    Caution  high temperatures    A Warning Consult Directions for Use   N Caution Lamp On     Lamp Off          Caution  high intensity light Type BF Applied Part     Boeg     w X Alternating Current Direct Current    ia Double Insulation    Illuminator is protected    against the effects of Transformer Plug   Not  IPX7 temporary immersion in IPX   protected from the ingress of  water  and the solutions water     described in this manual     Warnings and Cautions    A     gt     gt     gt   gt  gt  gt  PP  gt     WARNING  To avoid eye injury  do not look into the beam     WARNING  Lamp is harmful to skin if touched  Allow lamp to cool for 5  minutes before replacing  Lamp generates heat and should remain off until  just prior to and immediately after use  Do not place illuminator onto a  flammable surface if lamp is illuminated     WARNING  Disconnect transformer from outlet prior to any maintenance     WARNING  This product is for use with the Welch Allyn KleenSpec Single   Use Vaginal Specula only  Do not use the illuminator for any other use  Lamp  is hot and can cause a burn if used outside of the vaginal specula     WARNING  KleenSpec Vaginal Specula Illumination System is not suitable for  use in the presence of a flammable anesthetic mixture with air or oxygen or  nitrous oxide  An explosion may result
14. oes  not stay  retained into  580 series  specula or  78600  expendable  illuminator     Possible damage to the   Inspect retention wings for  illuminator retention damage  Replace illuminator  wings  REF 78800     Illuminator does   not stay plugged   llluminator transtormer  into the interconnect plug is  transformer damaged    cord     Faulty Lamp Replace with a new lamp   Light output      Inspect lamp lens for debris and  seems low  Dirty lamp lens yee P    This guide is intended to provide assistance towards determining the fault  condition of this product  Please contact the authorized Welch Allyn Service  Center listed within the product owners manual for additional assistance     Inspect interconnect plug for  damage  Replace either or both  REF 73405  REF 73410 or REF  78800        Troubleshooting Guide   Qualified Personnel Only  rT  Nopowertothe   power to the Verify that power is supplied to   that power is supplied to  transtormer outlet  transtormer outlet     Test the voltage supplied through  the transformer at the cord end   Verity the voltage reads   Faulty Transtormer approximately 4 7 volts DC  REF  73405  or 4 7 volts AC  REF  73410   Only properly trained  personnel shall perform this test     Verity that the illuminator is faulty  by replacing with a new illuminator  or with the switch in the on  position  and power supplied  through the transformer  above    remove lamp and measure the   Faulty Illuminator voltage between the lamp socket  center conta
15. tent Operation  Vag Spec and Illuminator    Approvals    Class Il  Type BF Applied Part  120V   60Hz  100mA   4 7 VAC  850mA   Not AP APG Equipment    91 4 cm  36 in   183 cm  72 in     100 hours  4 6 V  Welch Allyn part no  08800    IPX7  IPXO      10   C to   35   C  50   F to 95   F   95  RH  D00 hPa to 1060 hPa   20   C to  49   C   2   F to 120   F   95  RH   500 hPa to 1060 hPa    10 minutes on max  5 minutes off min    CERTIFIED TO  CAN CSA STD C22 2 NO  601 1  CONFORMS TO  IEC 60601 1  IEC60601 1 2  UL 60601 1 STD 2601 1    Device Directive     The CE Mark on this product indicates it has been tested to and  conforms with the provisions noted with the 93 42 EEC Medical      EC   REP   Regulatory Affairs Representative    Welch Allyn Limited  Navan Business Park    Dublin Road    Navan  County Meath  Republic of Ireland    Troubleshooting Guide    Power switch is in the off   Verify the power switch is in the  position  on position  Refer to manual     Verify that the illuminator is  properly plugged into transformer  cord     Transformer is not Verify the transformer is properly  plugged in  plugged into the outlet   E N Faulty Lamp Replace with anew lamp    Verity that the lamp is secured into  Loose Lamp     the illuminator    Verify that the lamp is a REF  Mono amb 08800 Welch Allyn lamp     Inspect the lamp and the o ring for  Damaged Lamp damage  Replace with REF 08800  lamp if damage is found     Illuminator is not plugged  into the transformer     Illuminator d
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
標本展開シート総合カタログ(PDF)  Télécharger  ZTEWelink MF210V2 Hardware Development Guide of Module  BARNIZ MUEBLES MATE    FCTN - DEC1.qxd  (-280 r281 r282 r283 v/—2t34  Model V10 Flotect® Mini-Size Flow Switch Specifications  SIM900_Hardware Design_V2.00  Service de dématérialisation du Boamp (acheteurs) (pdf    Copyright © All rights reserved. 