1. xxi ro 1000VA 2200VA 3000VA SENTINEL PRO UPS 700VA 1500VA PASONG 2200VA ER a AUTONOMIES Measured autonomy 100 linear load only internal batteries MISCELLANEOUS AC AC yield in ON LINE mode 87 2 88 9 90 4 90 6 91 2 8W 9W Automatic consumption in ECO mode 9W 10 4W 10 2W batteries disconnected DC AC yield in BATTERY mode 83 5 85 0 86 2 86 4 86 6 Automatic consumption from the 41W 46W 40W 65W 58W network batteries disconnected Automatic consumption in Stand 6W 6W 6W TW 14W Automatic consumption with 0 5W 0 5W 0 5W 0 5W 0 33W on off switch turned off by mode batteries disconnected W 80 100 130 180 BTU h 270 335 445 610 kcal h 68 85 112 155 Operating room temperature 6 C 0 40 Humidity lt 90 without condensation Operation 1000 m at nominal power 1 power for every 100 m above 1000 m 4000 m maximum Transport lt 15000 m l Excessive battery discharge overcurrent short circuit over Protection devices voltage undervoltage thermal Overvoltage protection 2 VDR x 300 Joule 40d a 158 x 422 x 235 190 x 446 x 333 N A versions ADDITIONAL INFORMATION Safety compliance EN 62040 1 and 2006 95 EC Directives EMC compliance EN 62040 2 cat C2 and 2004 108 EC Directives Power loss with resistive nominal load Installation height Certifications SPTSEPA1S11FREN rielo sxx ro T10 Battery Box T10 BATTERY BOX AB36 M1 BB36
2. 8Vdc without load VCC min 8Vde 25MA 4 3 Firmware The firmware of the UPS unit can be updated by inserting the appropriate programming card into the expansion slot This operation must be carried out by authorized personnel SPTSEPA1S11FREN
3. A3 BB36 M1 AB72 M1 BB72 A3 BB72 M1 Rated battery voltage Vdc 36Vdc 72Vdc Number of batteries V no V 0 12V 3 12V 3 3 12V 0 12V 6 12V 6 6 12V 0 7 7 14 Standard capacity Ah Dimensions L x D x H mm 158 x 422 x 235 190 x 446 x 333 Packaging dimensions L x D x H mm 245 x 500 x 340 325 x 585 x 470 14 21 12 27 41 Net weight Kg 6 3 2 T12 Battery Box Rated battery voltage Vdc 36Vdc 72Vdc 36Vdc 72Vdc Number of batteries V no V 3 12V 3 12V 0 12Vdc Standard capacity Ah 40 odo o Dimensions Lx D XH mm 158 x 422 x 235 Packaging dimensions L xD x H Net weight Gross weight SPTSEPA1S11FREN Wi riellosss sxx ro 4 COMMUNICATION PORTS AND FIRMWARE The UPS comes with a standard RS 232 port with input and output signals a USB Port and an expansion slot for connecting additional electronic boards RS 232 CONNECTOR RS 232 CONNECTOR PIN SIGNAL NOTES Programmable output default UPS shutdown 2 ia Opto isolated contact max 30Vdc 35mA 3 RXD These contacts can be associated with other events 4 Programmable input using the appropriate software default disabled 5 GND Opto isolated control 5 15Vdc 6 DC Power Supply Imax 20mA These contacts can be associated with other events l Programmable input using the appropriate software aasaran ga For additional informati
4. PRO UPS 700VA 199ovA 1500VA 3000VA OUTPUT Rated voltage Selectable 220 230 240 Static variation 3 1 5 Dynamic variation 4 lt 5 in 20 msec Voltage distortion linear load lt 2 Voltage distortion distorting load lt 5 Frequency 5 Hz Selectable 50 60 Hz automatic detection Current crest factor gt 3 1 Rated power 1000VA 1500VA 2200VA 3000VA Rated power W 560W 800W 1200W 1760W 2400W Derating Frequency converter forced frequency 30 de synchronization Bypass line available activates the bypass after 2 sec Overload 100 lt load lt 110 shut down after 120 sec Bypass line unavailable shutdown after 60 sec Bypass line available activates the bypass after 2 sec Overload 110 lt load lt 150 shutdown after 4 sec Bypass line unavailable shutdown after 4 sec Bypass line available activates the bypass Load overload gt 150 MAMANE shutdown after 1 sec Bypass line unavailable shutdown after 0 5 sec e Short circuit current lt Power VA 220V x 2 Inverter short circuit shutdown after 300ms 3 Network Battery 0 100 load 4 Network battery network 0 100 0 resistive load 5 If the network frequency is within 5 of the selected value the UPS is synchronized with the network If the frequency is off tolerance or battery powered functionality is enabled the frequency is that which is selected 0 1 SPTSEPA1S11FREN Wi riellosss
5. 3 Thermal switch 2 3 Battery Box front panel 2 4 Battery Box rear panel 36V Battery Box 72V 7X Battery Box Box 1 Battery disconnection switch SWBATT 2 Battery expansion connector SPTSEPA1S11FREN Wiriellovps 25 BBox T12 rear panel 36V Battery Box 1 Battery disconnection switch SWBATT 2 Battery expansion connector SPTSEPA1S11FREN SENTINEL PRO 72N Battery Box rielo mmo 3 TECHNICAL DATA TABLE 3 1 SENTINEL PRO UPS 1 1000VA 2200VA 3000VA SENTINEL PRO UPS 1500VA 1000VA 2200VA ER 3000VA ER ER INPUT Rated voltage 220 230 240 Maximum allowed input 300 voltage Maximum 276 Vac Minimum 184 Vac AT 100 load Minimum 184Vac 140Vac from 100 to 50 load in linear mode Return to network powered functionality 190 Vac Rated frequency Hz 50 60 gt 0 98 Current distortion maximum load distortion Current distortion maximum load maximum load lt 7 Rated current only for ER Versione Q220V2 8 IZ NA versions 2 1 O rated load minimum voltage of 184 Vac battery charging 2 rated load rated
6. B and RS 232 Port SNMP ModBus etc e RS 232 and USB communication ports e Frequency converter mode with a derating of 30 e Free Running mode with a derating of 30 e Eco mode function with 98 yield 1 2 Standard Versions TOOVA 560W PF 0 8 2 batteries 12V 7Ah small cabinet 1000VA 800W PF 0 8 3 batteries 12V 7Ah small cabinet with battery expansion 1500VA 1200W PF 0 8 3 batteries 12V 9Ah small cabinet 2200VA 1760W PF 0 8 6 batteries 12V 7Ah large cabinet with battery expansion 3000VA 2400W PF 0 8 6 batteries 12V 9Ah large cabinet with battery expansion 1 3 ER Versions for extended autonomy e 1000VA ER 2200VA ER 3000VA ER e Same features as the standard version SPTSEPA1S11FREN SENTINEL PRO Wi riellovps 2 SENTINEL PRO SERIES UPS AESTHETICS 2 1 SENTINEL PRO front panel Chassis reference colour Pantone Black 6U Colour of the silver parts RAL 9006 1 Display 2 Multifunction keys 3 ON OFF button SPTSEPA1S11FREN Wriellovss m 2 2 SENTINEL PRO rear panel SPTSEPA1S11FREN Wlriellov ps SENUNELPRO 4 RS 232 communication port and opto isolated contacts 5 USB Port 6 Expansion slot 7 Cooling fans 8 Battery expansion connector 9 IEC 16A output socket 10 IEC 10A output socket 11 IEC 16A input plug 12 IEC 10A input plug 1
7. RIELLO ELETTRONICA SENTINEL PRO Mrielogg Sama 1 2 GENERALDESCRIP TION a pi e E E EAE OE A AEE arr 3 1 1 Manta UPUAN E e AA T AA 4 1 2 DRA AP q e A 4 1 3 ER Versions for extended autonomy i 4 SENTINEL PRO SERIES UPS AESTHETICS sssirnsraconinetesonrirrn acosta orcas 5 2 1 SENTINEL PRO front LY la eer snena ENR ENEA EENE EEE EEE ECAR E EAEE EAE EEROR EEEE 5 22 SENTINEL PRO reat pane AA a 6 2 3 Battety Box front lactato oir 7 2 4 Batory DOC PAN la AA ANNA AA ANA tnt f 29 BPO A r e PP e o E lr MO E PU O E E ERE OO PS oi 8 TECHNICAL DATA TABLE iano eni iaia 9 3 1 SENTENE eT Css esc eee vagy ss setae asirio pi 9 l TO EU RR EEA 12 IL d A AT 12 COMMUNICATION PORTS AND FIRMWARE scsi 13 4 1 Examples for connecting signals through the RS 232 port nnnnnnnnrr nn ana nnn nn ena nannti nn tna 14 4 2 Technical data for pin 6 power through the RS 232 port eeennnnnnnnnnnnrnnnnanannnennn nn nanna nnnnn nanna 14 4 3 Fide 14 SPTSEPA1S11FREN Miele eno 1 GENERAL DESCRIPTION The SENTINEL PRO family UPS is an online single phase unit with power levels of up to 3KVA in a cabinet tower configuration of two different sizes based on the power required That UPS is designed to be configured for various operating modes ON LINE is the operating mode which offers maximum load protection and the best output waveform quality ECO is the operating mode which offers the least UPS co
8. d any network disruptions will have a direct effect on the load This family of UPS units is completed with relative battery cabinets The BB36 and BB72 Battery Boxes have the same aesthetic design as the UPS units and are capable of housing one or two battery branches in parallel The BB36 B1 and BB72 B1 Battery Boxes are larger battery cabinets which are suitable for housing 40 Ah batteries Both Battery Box versions are available without batteries These versions come complete with all of the required kits so that the user can decide upon the most suitable configuration to meet his her needs All of the Battery Box versions are supplied without battery charger boards For increased recharging current ER version UPS units are available which contain high powered battery charger boards instead of batteries SPTSEPA1S11FREN Wriellosss nano 1 1 Main features of the UPS unit The main features of the SENTINEL PRO series include e VFI On line pure sinusoidal waveform during battery powered functionality e Output frequency with automatic selection auto sensing e Front rear ventilation e LCD display e UPS with configurable and customizable functions i e by pass thresholds automatic testing acoustic alarm etc through proprietary configuration software e Protected battery expansion connector e Unlimited expandability of autonomy with dedicated or custom Battery Boxes e Expansion slot for communication cards i e second US
9. nsumption or rather maximum efficiency SMART ACTIVE is the operating mode which allows the UPS to decide whether to enable ON LINE or ECO functionality based on a statistic regarding the quality of the Power Supply network STAND BY OFF Mode 1 is the operating mode in which the UPS functions as an emergency device While power is present the UPS does not intervene In the event of a blackout the necessary power is provided by the UPS the effective values rms of the voltage and the output frequency are constantly controlled by the microprocessor independently with respect to the waveform of the network voltage thereby maintaining the output frequency synchronized with the network within a configurable interval Outside of this interval the UPS eliminates its synchronism with the network and brings itself to its nominal frequency under these conditions the UPS cannot utilize the bypass In order to optimize yield the load is normally powered by the bypass in ECO mode In the event that the network should move outside of the preset tolerances the UPS will switch to ON LINE functionality Once the network has moved back within the preset tolerances for at least five minutes the UPS will go back to powering the load through the bypass ADDITIONAL FUNCTIONS MANUAL BYPASS The Manual Bypass function allows the UPS to be switched to the bypass line In this configuration the load is powered directly by the input network an
10. on about interfacing with the UPS 8 default discharge pre alarm unit please refer to the appropriate manual 9 Programmable output default battery powered functionality COMMUNICATIONS SLOT The UPS comes supplied with an expansion slot for optional communication cards see the diagram on the right which can allow the device to communicate using the most common communication standards Some examples include e Additional RS 232 and USB communication ports e Serial duplicator e Ethernet network card with TCP IP HTTP and SNMP protocols e JBUS MODBUS protocol converter card e PROFIBUS protocol converter card e Card with isolated relay contacts Please consult the website www riello ups com to check the availability of additional accessories Kati MEL j E 1 1 W SPTSEPA1S11FREN Wirielloups O PR 4 1 Examples for connecting signals through the RS 232 port UPS CUSTOMER INTERNAL CIRCUIT EXAMPLE FOR THE EXTERNAL CIRCUIT EXTERNAL POWER VEXT 7 5 15V 12V PIN 6 All PIN 1 MALAY B L PIN 8 _ B W PIN 9 ANDI GND PIN 5 GNDEXT VEXT 5 15V 12V PIN 6 SWITCH EN SWITCH REMOTE ON REMOTE OFF INPUT2 PIN 4 cl INPUT1 PIN 7 CUPTER a i GND PIN 5 GNDEXT 4 2 Technical data for pin 6 power through the RS 232 port The voltage provided by the serial port s 6pin power depends on the absorbed current VCC max 10
11. voltage of 220 Vac battery charging BYPASS Accepted voltage range for Vac Minimum configurable threshold 180 200 switching Maximum configurable threshold 250 264 Accepted frequency range for Selectable 3 10 inverter synchronization Default 5 Switching time msec Typical 4 BATTERY Number of batteries V no V 2 12V 3 12V 3 12V Standard capacitv Ah 7Ah a 7Ah a 9Ah b 0 7 0 8A UPS on with maximum Pi ka rato ore A About 1A with UPS in Stand Bv Charging time c h lt 4h for 80 of the load Voltage range for no battery intervention configurable through UPSTools Expandability o rated Not Not voltage of the Battery Box ra bya Kae ds ro current only for ER 8A d versions Minimum Battery Box capacity N A gt 40Ah e gt 40Ah e only for ER versions SPTSEPA1S11FREN Wi riellosss xxi reo 12V 7Ah Batteries CSB GP1272 F2 or CSB GP1272 28W or CSB UPS12360 7 or YUASA NPW36 12 12V 9Ah Batteries CSB HR1234W F2 or YUASA NPW45 12 For the ER versions the charging time depends on the batteries installed in the Battery Box The charging current depends on the input voltage and the internal temperature of the UPS Under normal conditions temperature derating of about 2 3A may occur e In order to select the minimum capacity of the Battery Box verify the maximum charging current accepted by the batteries 1000VA 2200VA 3000VA SENTINEL
Download Pdf Manuals
Related Search
Related Contents
Zanussi ZCE 651 Instruction Manual Lenovo px12-450r PRESS RELEASE - リンクスインターナショナル 2009年7月 \(Microsoft Word - Manual MP3 Portugu\\352s revisado.doc\) Esta Navidad Especial Accesorios Bosch ZKit-51-V664, 8051 Development Kit C6150 UG ls 59299203 Rev 1.0.book プログラミング・ガイド smart H2 O - Thermo Fisher Copyright © All rights reserved.