Home
SS-CYC-100 Spectra-Cyc™ Series Installation
Contents
1. AND INSTRUCTION MANUAL RESOLUTION is selectable as either 8 Bit one DMX channel per color this is normal resolution or 16 Bit two DMX channels per color Coarse Fine high resolution similar to moving lights If unit is in 8 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red CH2 Green CH3 Blue CH4 Amber If unit is in 16 Bit Mode and the unit was set to DMX Channel 001 then the DMX channels would be CH1 Red Coarse CH2 Red Fine CH3 Green Coarse CH4 green Fine CH5 Blue Coarse CH6 Blue Fine CH7 Amber Coatse CH8 Amber Fine MASTER is selectable as ON or OFF and provides a Master fade channel that dims all 4 colors proportionally at the same time in order to maintain the color If you are in 8 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red CH2 Green CH3 Blue CH4 Amber CH5 Master If you are in 16 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red Coarse CH2 Red Fine CH3 Green Coarse CH4 Green Fine CH5 Blue Coarse CH6 Blue Fine CH7 Amber Coarse CH8 Amber Fine CH9 Master Coarse CH10 Master Fine SMOOTHING is selectable as ON or OFF and provides a smooth transition ramp from one level to another in a similar way to how an incandescent lamp behaves This helps to eliminate the steppiness associated with LED fixtures that is c
2. MODE While in stand alone mode the hundreds button cycles through r G b and A colors The tens and ones digits select 0 99 values 99 is actually full The 0 255 scale is spread evenly over the 0 99 display range NOTE when you go in or out of fixed color mode the display will go blank Touch any button to turn on display INSTALLATION AND INSTRUCTION MANUAL Locked Mode To Lock or unlock the buttons gt Wait a few seconds until the display goes blank gt press and hold the ONES button gt press and hold the HUNDREDS button gt release the ONES button gt release the HUNDREDS button Display will show LOC for a moment and then blink Buttons will have no effect until they are unlocked Master and Slave Mode To Turn On or Off the MASTER gt Wait a few seconds until the display goes blank gt press and hold the HUNDREDS button gt press and hold the ONES button gt release the HUNDREDS button gt release the ONES button Display will show ON or OFF fora moment and then blink INSTALLATION AND INSTRUCTION MANUAL This manual is also available online at www altmanlighting com
3. cable itself For floor mounting Lay the unit on a flat leveled surface and adjust the rubber feet to the desired tilt angle The fixture yoke is not needed for Ground Cyc applications Connecting power to the fixture Plug the fixture into a properly grounded receptacle 100 240 vAC connected to a circuit breaker An Edison receptacle is provided on the back of each luminaire for powering a neighboring Spectra Cyc 100 only Up to 6 Spectra Cyc s maximum should daisy chain power in this fashion Focusing the fixture With the fixture energized point the unit in the direction of the object to be illuminated Adjust the yoke or feet to the desired position The optimum distance for best results is 4 to 5 feet away from the projection surface Cleaning the fixture Routine cleaning of the SS CYC 100 lighting fixture will provide years of prolonged use Use compressed air to blow off any dust and dirt from the lens reflector electronics and heat sink For the lens use a soft lint free cloth dampened with water to clean the lens of dust and dirt Dry off completely with compressed air or a dry lint free cloth ETL FILE LISTING The SS CYC 100 lighting fixture is ETL and C ETL listed under Altman File 9700680 for Portable Electric Luminaires INSTALLATION AND INSTRUCTION MANUAL FEATURES The SS CYC 100 LED lighting fixture is the first of its kind in the Theatrical and Architectural Lighting Industry and adds to the Spectra LED family of s
4. ALTMAN LIGHTING INC SS CYC 100 Spectra Cyc Series Installation and Instruction Manual 2010 Altman Lighting Inc 57 Alexander Street Yonkers New York 10701 U S A Phone 914 476 7987 Fax 914 963 7304 Specifications are subject to change without notice vee Copyright 2010 Rev 2010 08 30 Lighting BRINGING IMAGINATION TO LIGHT w altmanlighting com SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS FOR SS CYC 100 SERIES LED LIGHTING FIXTURES WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS 1 Turn off unplug power and allow fixture to cool before cleaning or servicing 2 Ensure that fixture is properly grounded 3 Ensure that ventilation slots are not obstructed 4 Do not look directly at lighted LEDs 5 Keep away from flammable materials 6 No user serviceable parts inside Replace entire LED assembly 7 Do not touch the LEDs at any time Use a soft lint free cloth to clean lens Do not use solvents to clean Use cloth dampened with water Allow to dry completely before reenergizing 8 Do not operate the unit with a missing or damaged lens INSTRUCTIONS DE SURETE LES INSTRUCTIONS AU SUJET D UN RISQUE D INCENDIE LE CHOC ELECTRIQUE OU LA BLESSURE AUX PERSONNES POUR SS CYC 100 AVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE LE CHOC ELECTRIQUE OU LA BL
5. ESSURE AUX PERSONNES SUIVRE CES INSTRUCTIONS DE SECURITE IMPORTANTES 1 Eteignez d branchez la puissance et permettez au montage de se refroidir avant le nettoyage ou l entretien 2 Assurez vous que le montage est correctement reli la terre 3 Assurez vous que des fentes de ventillation ne sont pas obstru es 4 Ne regardez pas directement la LED allum e 5 S loigner des materiaux inflammables 6 Aucunes pi ces utiles d utilisateur l int rieur Remplacez la LED enti re 7 Ne touchez pas la LED tout moment Employez un chiffon non pelucheux mou pour nettoyer l objectif N employez pas les dissolvants pour nettoyer peut employer le tissu humect de l eau laissez s cher compl tement avant de reenergizing 8 Ne pas faire fonctionner l appareil avec un diffuseur ant rieur ou une lampe INSTALLATION AND INSTRUCTION MANUAL SS CYC 100 Spectra Cyc LED Series Solid State Lighting Fixture DESCRIPTION The SS CYC 100 LED lighting fixture is a portable unit with a flexible power supply cord The overall construction of the fixture includes corrosion protected aluminum housing and allows for a yoke or mounting brackets The fixture is supplied with a state of the art microprocessor controlled solid state LED light engine incorporating 3 watt Luxeon Rebel Red Green Blue and Amber color LEDs and an on board power supply The LED substrate is coupled to a highly efficient heat sink and cooling sy
6. alone Effects This is the default mode for a new unit DMX address To set press the buttons repeatedly or hold to count up until the desired DMX address 1 512 appears on the display Wait a few seconds the display will blink once quickly and the address is set live and retained in memory even if you remove power RDM addressing sent from a remote unit will overwrite local DMX setting PERSONALITIES There are 8 different personalities Each personality is made up of 3 settings RESOLUTION 8 Bit 16 Bit MASTER On Off and SMOOTHING On Off which ate explained in greater detail below The current active Personality is displayed for about 1 second during power up The format is Pxx where xx is replaced by the active personality 01 08 To set the desired Personality you must be in Normal mode not Fixed Color mode To select the personality gt Press the buttons until the desired personality address 601 608 appears in the display see list below gt Wait a few seconds and a confirmation display will appear that shows a question mark on the left followed by the personality This gives you an opportunity to either accept or reject the new setting To accept the personality press the ONES button To reject the personality press the HUNDREDS button below the Once the new personality is accepted it is entered into memory and retained even if power is disconnected Once personality is either accepted
7. aused by the instantaneous response of LEDs INSTALLATION AND INSTRUCTION MANUAL STAND ALONE EFFECTS does not require a control console Note stand alone effects from a single unit will control other units connected via DMX cable to all synchronize Set other units to DMX Channel 001 Do not use the Stand Alone Effects while connected to a control console or a conflict will result Color Fades 700 799 700 709 R gt A gt G gt B fade 700 faster 709 slower 740 749 B gt G gt A gt R fade 740 faster 749 slower 780 789 R gt A gt G gt B gt W fade 780 faster 789 slower 790 799 W gt B gt G gt A gt R fade 790 faster 799 slower Strobes 800 879 800 809 WHITE STROBE 800 faster 809 slower 810 819 RED STROBE 810 faster 819 slower 820 829 AMBER STROBE 820 faster 829 slower 830 839 GREEN STROBE 830 faster 839 slower 840 849 BLUE STROBE 840 faster 849 slower 850 858 R A G B RAINBOW STROBE 850 faster 859 slower 870 879 B G A R RAINBOW STROBE 870 faster 879 slower Fixed Color Mode This is a special mode that allows you to manually select colors for a single unit using the 3 keys To enter Fixed Color Mode or exit to Normal Mode gt Wait a few seconds until the display goes blank gt press and hold the ONES button gt press and hold the TENS button gt release the ONES button gt release the TENS button STAND ALONE FIXED COLOR
8. olid state LED luminaires offered by Altman Lighting Four Colors Red Green Blue and Amber for more color combinations and better CRI Compatible with DMX512 and RDM protocols including Wybron Responder System 8 16 bit DMX512 control for smoother dimming Patent pending optical system utilizing Homogenized Pixelation lens provides smooth even illumination and reduces pixelization from projected view On board powert supply microprocessor controller and current drivers Feed thru DMX RDM data with a maximum total run of 1000 feet On board convenience power outlet Push button addressing Stand Alone Pre programmed modes Built in flicker free TV mode Keypad Lock functions to prevent accidental Re Programming Efficient cooling system offering Silent Operation with No Fans INSTALLATION AND INSTRUCTION MANUAL OPERATION Firmware Version V2 20 Date 2010 03 04 SETTINGS There are 3 buttons below the 3 digit LED display on the side of the unit The buttons are From left to right HUNDREDS TENS ONES All settings for Modes DMX address Personalities etc can be made by using the three buttons on the back of the unit while power is on Note Display goes out after no activity for approx 4 sec Touch any button once to bring it back on There ate 3 main operating Modes Normal Fixed Color and Locked Normal Mode Normal Mode is used for Setting DMX address Personalities and Stand
9. or rejected the display will go back to the current DMX address The default personality for a new unit is 02 INSTALLATION AND INSTRUCTION MANUAL EXAMPLE Let s say that we want to select personality 05 We enter 605 on the display After a few seconds the display will show 705 Since we want this we press the ONES button below the 5 and that enters personality 05 into memory PERSONALITY ADDRESS SETTINGS LIST 601 608 4 COLOR CHANNELS Personality 01 uses 4 DMX channels Personality 02 uses 4 DMX channels Personality 03 uses 5 DMX channels Personality 04 uses 5 DMX channels Personality 05 uses 8 DMX channels 8 Bit Master OFF Channel order is RGBA 8 Bit Master OFF Channel order is RGBA 8 Bit Master ON Channel order is RGBAM 8 Bit Master ON Channel order is RGBAM 16 Bit Master OFF Channel order is RrGgBbAa Personality 06 uses 8 DMX channels 16 Bit Master OFF Channel order is RrGgBbAa 607 Personality 07 uses 10 DMX channels uses 10 DMX channels 16 Bit Master ON Channel order is RtGgBbAaMm 608 Personality 08 16 Bit Master ON Smoothing ON Channel order is RtGgBbAaMm PERSONALITY ADDRESS SETTINGS LIST 609 612 1 COLOR CHANNELS Personality 09 uses 1 DMX channel Personality 10 uses 1 DMX channel Personality 11 uses 1 DMX channel Personality 12 uses 1 DMX channel Smoothing ON INSTALLATION
10. stem for prolonged life of the LEDs The fixture can be ceiling mounted to a pipe or floor mounted All components and electrical devices are ETL Listed or Recognized A safety cable is provided for use when securing the fixture to a pipe PACKING LIST The SS CYC 100 LED lighting fixture is shipped with the following SS CYC 100 with Safety Cable Power Supply Cord with molded Edison power plug Installation and Instruction Manual Optional Yoke WARNING ALL ELECTRICAL WIRING AND CONNECTIONS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN INSTALLATION AND INSTRUCTION MANUAL SETUP AND INSTALLATION Unpacking Remove the SS CYC 100 lighting fixture from its shipping box Set the unit down on a flat surface before proceeding Lamping and Re lamping The SS CYC 100 lighting fixture is provided with an integral LED light engine Under normal operating conditions the LED light engine should have a rated life expectancy of over 50 000 hours There are no user serviceable parts inside The entire LED assembly will need to be changed Mounting the fixture For Sky Cyc ceiling mounting Install the Yoke kit and a Pipe Clamp if desired Loosen the bolt on the pipe clamp mounted on top of the fixture yoke until the clamp fits snugly around the mounting pipe Make sure the clamp wraps securely around the pipe surface Tighten up the bolt securely to the pipe Next loop the safety cable around the pipe and yoke and then clip it back onto the