Home
TE10A Product data
Contents
1. lt SINGLE PHASE POWER CONTROLLER BURST FIRING and PHASE ANGLE OPERATION TE10A Product data An Invensys Company TELOA Single phase power controller Multiple applications T he E 10A is a single phase power controller with DC input that is designed for general purpose single phase applications where resistive inductive temperature dependent or infrared loads are involved T ypical applications include automotive industry paint drying food processing cooking browning environmental temperature control heat treating plastics extrusion thermoforming and textiles drying coating printing Ergonomic design T he T E 10A is easily integrated into a control system because of its compact size simplicity of wiring and DIN rail mounting T his design allows a significant reduction in cabinet size and lowers maintenance costs High performance T he T E 10A performs with a control precision of 2 of maximum voltage and a linearity of better that 296 of full scale Automatic compensation for supply fluctuations enables constant output power to be maintained for constant load despite variations in supply voltage Flexibility T he T E 10A has in addition to the standard burst single cycle and phase angle firing modes an advanced single cycle firing mode suitable for short wave infrared loads T he T E 10A is controlled by an external analog signal which is selectable for D C current or voltage
2. Alternately an internally provided 5V user voltage allows local control by a potentiometer A plug in signal connector avoids any risk of wiring error if the unit has to be replaced T he T E 10A can be used with arange of standard single phase voltages but it can also be used to control non standard voltages by using an optional auxiliary supply 115V 230V T he T E 10A may be mounted in a panel cut out or DIN rail mounted or bulkhead mounted inside a cabinet Toughness Reliability T E 10A SCR s can withstand momentary overcurrents up to 15 times the nominal rating T his is important when controlling short wave infrared elements T he SCR breakdown voltage is three times greater than the nominal operating voltage Current derating curves as a function of ambient temperature enable T E 10A units to be used up to 60 C CE Marking Safety T E 10A units meet the essential requirements of the E uropean L ow Voltage Directive N o exposed parts are at a dangerous voltage Barber Colman certifies that T E 10A units have successfully passed E lectromagnetic Compatibility EM C tests and enable the system which incorporates them to comply with the EMC Directive when used in compliance with the Product U ser M anual EMC filters are internal to the T E 10A external filters are needed for phase angle operation Firing modes T T E 10A is available in four firing modes Phase Angle Firing with optional current limit for use with inductive an
3. Burst mode 440 volts 440V Required AX 144 output of temperature controller 0 to 10V 480 volts 480V N otes For control by local potentiometer or by 500 volts 500V contacts use the input product code 0V5 For non standard line voltage use the product code for the voltage immediately above and choose auxiliary power supply as an option EXTERNAL HIGH SPEED FUSES AND FUSEHOLDER Nominal CURRENT DERATING current of Fuse Code for fuse Fuse IN Nominal TE10A rating and fuse holder alone oar 16A 20A FU1038 16A 00 CH260024 by 50 25A 32A FU1038 25A 00 CH260034 50A 63A FU2258 50A 00 CS173087U063 40 Remember 5 x aa The external high speed fuses recommended for the TE10A are used only for SCR protection and under no circumstances should they be used to protect the j 20 installations These fuses are not suitable for use with short wave infrared elements z m sobre programac o www soliton com br e mail soliton soliton com br SOLITON CONTROLES INDUSTRIAIS LTDA Rua Alfredo Pujol 1010 Santana Sao Paulo SP Tel 11 6950 1834 Fax 11 6979 8980 e mail vendas soliton com br 1415 DB 002 0 01
4. mark in compliance with the European Low Voltage Directive Complies with the Low Voltage Directive 73 23 EEC amended by the Directive 93 68 EEC product installed and used in compliance with its user manual TE10A products comply with the Electromagnetic compatibility standards Immunity G eneric standard EN 50082 2 Test standards EN 61000 4 2 EN 61000 4 4 50140 EN V 50141 50204 Emission G eneric standard EN 50081 2 Test standard EN 55011 with external filter for Phase Angle firing model internal filter fitted on Burst Firing model Product standard 1800 3 A CE declaration of conformity is available on request Environment Temperature Storage Safety standards Atmospheres Humidity SCR protection Protection degree Isolation 1 minute test Cooling Dimensions W eight Mounting O perating 0 to 45 C up to 60 C with derating 10 to 70 EN 61010 installation category 3 voltage transients must not exceed 4 0KV Electrically conductive pollution must be excluded from the cabinet in which this controller is mounted This product is not suitable for use above 2000m or in corrosive or explosive atmospheres without further protection Relative humidity 5 to 9596 non condensing and non streaming High speed external fuse order separately Internal V varistor and RC snubber IP20 in accordance with IEC 529 11 4 table 5 Isolation distances comply with IEC
5. 664 Between power and ground 2000Vac Between power and control inputs 3600Vac Natural convection Height 4 5 115mm Depth 3 6 92 5mm Width TE10A 16A 2 1 52 5mm TE10A 25A 2 6 70mm 10 50 4 8 122 5mm 10 16 1 2 lb 5500 TE10A 25A 1 5 Ib 700g 10 50 2 6 Ib 12009 Vertical on DIN rail reference EN 50022 35x7 5 or 35x15 Allow atleast 0 4 10mm between units Warranty 2 years parts and labor return to factory DIN rail 52 5 164 70 254 105 404 122 5 50 Basic Nominal Nominal Input product current voltage Input Firing O ption 0 5Vdc 0 5 0 10Vdc 0V10 TE10A AX 144 4 20mAdc 4mA 20 Firing Burst firin FC Basic product Code Nominal voltage mng Single cycle FC1 TE10A 100 volts 100V Advanced single cycle SCA Nominal current 115 volts 115V Phase angle PA 16 amps 16A 200 volts 200V Option 25 amps 25A 230 volts 230V p Aux power supply 115 volts 115V 50 amps 50A 240 volts 240V 277 volts 977 230 volts 230V Current limit phase angle only CL 380 350 30 to 100 of nominal current E xample of product coding 400 volts 400V M MOT TE10A 25 230V 0V10 FC 144 415 volts 415V End Code 20A load used at 230Vac firing in
6. Automatic compensation for supply variations from 10 of the nominal voltage Stability better than 296 of the full range with constant resistance Burst firing Single cycle or advanced Single cycle At50 power the SCR s are On for 300ms and Off for 300ms typical time in Burst firing On for one cycle and O ff for one cycle in Single cycle and advanced Single cycle At 66 796 power the SCR s are On for 400ms and Off for 200ms in Burst firing On for two cycles and ff for one cycle in Single cycle On for one cycle ff for half a cycle in advanced Single cycle SCR firing atzero voltage On indicated by a green LED Phase Angle firing varies the SCR conduction angle Current limit is available as an option on this model Control Input signal Local control Contacts Control terminals Analog DC voltage or current 0 5V 0 10V or 4 20mA Voltage input impedance 100 current input impedance 2500 10kQ external potentiometer a 5V user voltage is available Contacts for O n Off logic operation Plug in connector 0 5 to 1 5mm2 cables Tightening torque 0 4N m Option Auxiliary power supply O ption for separate electronics power supply fed from 115Vac or 230Vac when using non standard mains supply Approvals and European Directives 4 marking Electrical safety Electromagnetic compatibility UU cUL listed TE10A products carry the CE
7. d temperature dependent loads Burst Firing and Single Cycle for use with infrared heaters as well as conventional resistive loads Advanced Single Cycle for use with short wave infrared heaters low flicker Advanced Single Cycle operation reduces the flicker and brightness of short wave infra red heaters compared to voltage a Standard Single cycle standard Single Cycle F or outputs of less than 50 the h on periods are single cycles 16 67mS at 60 H 2 5 t LES UNE E xamples of firing in Single cycle a and in advanced Single cycle b modes at 66 696 of nominal power TECHNICAL SPECIFICATIONS Power Nominal current at 45 Nominal line to line voltage Supply frequency Load Power terminal block Safety ground 16 25 or 50A see current derating curve 100Vac to 500Vac 10 15 for operating voltage see product code 50 and 60Hz 2Hz Resistive or short wave infrared elements use TE10A Burst Firing single cycle or advanced single cycle firing Inductive infrared or temperature dependent loads use TE10A Phase Angle Firing Cage terminals for 1 5 to 16 mm2 cables Tightening torque 1 2N m Screw terminal same cable gauge as power Tightening torque 2N m Control Performance Control type Linearity Stability Firing modes Burst Firing Model Phase Angle Model The power controlled in the load is proportional to the setpoint Better than 2 of the full range