Home
DCC200 Manual - Healing Digital
Contents
1. Vmax 755MV pp Modes Dual Sound and Stereo Support 8 3 MPEG TS Output Connectors 2x BNC ASI 1 ASI stream Duplicated Standard DVB ASI output Complies with EN50083 9 ASI interface Bitrate Max 170Mbps Bitrate Effective Channel 3 15 Mbps ASI Mode BYTE Packet size 188 204 byte Return Loss 10dB Impedance 75ohm 8 4 Video Channel Coding Compression Standard Compiles to MPEG 1 MPEG 2 MP ML 4 2 0 Bitrate 3 15 Mbps Resolution MPEG Full D1 Half D1 SIF OSIF Resolution PAL Max 720x576 Resolution NTSC Max 720x480 Page 21 of 23 8 5 Audio Channel Coding Compression Codec MPEG 1 Layer 1 MPEG 1 Layer 2 Audio Sampling Rate kHz 32 44 1 48 Audio Codec Bitrate kbit s 128 256 384 8 6 Control Front Panel Interface LCD Display and Navigation Keys SNMP LAN Connection and Windows Software 8 7 Power Voltage AC 90 260V Frequency 50 60 Hz Max Load 30W 8 8 Environmental Operational Temperature 10 to 50 C Storage Temperature 10 to 70 C Humidity 10 to 95 Page 22 of 23 9 CONTACT INFORMATION LACEYS TV Head Office Seaford 42 Brunel Road Seaford Victoria Australia 3198 Telephone 03 9776 9222 Fax 03 9776 9766 Email technical laceys tv http www laceys tv Version 1 00
2. 9 Use the following IP address Obtain DNS server address automatically Enter the IP address and Subnet mask DCC 200 defaults shown Alternate DNS server Figure 12 IP settings Settings shown connect to the DCC 200 s default settings Page 15 of 23 6 1 3 Selecting a IP and Subnet The communicating computer only varies its address within the same subnet For example if the DCC 200 has the IP address 192 168 0 136 with the subnet 255 255 255 0 then the computer accessing the DCC 200 must have an IP address of 192 168 0 xxx where xxx is any number between 1 and 255 except for 136 Note No other device on the same subnet can have the same IP address 6 2 Control Software The Control Software is supplied on CD or by E Mail The software runs on Windows XP Windows Vista or Windows 7 No installation needed simply run the executable from a directory on your computer uae NMS 4channel Encoder Figure 13 Icon of the DCC 200 software Page 16 of 23 7 CONFIGURATION SNMP Please follow the steps in the setup section before attempting the configuration On loading NMS 4channel Encoder a message will appear Fig 6 this message appears when the software is not yet connected to a DCC 200 Please ignore this message and click ok to continue 4 1 Encod Refresh Error Figure 14 Please Ignore and click ok Once loaded the default screen will load up Most of the options are t
3. contact Laceys TV for support Page 4 of 23 4 SETTINGS AND CONNECTIONS The DCC 200 is Plug and Play and may be installed with no extra configuration 4 1 Connections Inputs CVBS R L Output ASI Ethernet LAN Power Figure 2 Photo of back of DCC 200 Show the BNC Ethernet and Power Connectors Including a Power Switch 4 1 1 Input Use the cables supplied to connect the A V equipment to the DCC 200 BNC connectors A V Source DCC 200 Figure 3 Shows the basic connection of an A V Source to the DCC 200 the cables supplied connect the Video and Stereo audio to the BNC connectors on the DCC 200 Page 5 of 23 4 1 2 Output The DCC 200 outputs the encoded MPEG 2 Streams via DVB ASI The DCC 200 has two duplicate DVB ASI outputs therefore two devices can use the one DCC 200 as a MPEG 2 source EXM 2 duplicate optional Figure 4 There are two ASI output on the DCC 200 the second output is a duplicate of the first 4 2 Control LCD Display Status LEDs Movement Level Select Figure 5 Front Panel of the DCC 200 shows the Button Interface including the ENTER and MENU buttons 1 eim Figure 6 The DCC 200 front panel interface button layout Use the ENTER button to enter a submenu or change a value Use the MENU button to go back Page 6 of 23 4 2 1 Channel Naming The Default labels of the channels are as follows Provider Name Program
4. 8 2 Audio Sample Frequency 48 44 1 32 kHz 3 Audio Layer Layer 2 Layer 1 4 Audio ES Mode STEREO SINGLE CHANNEL DUAL CHANNEL JOINT STEREO 1 3 System Settings 1 Channel Bitrate kbit s 6000 Value from 1000 to 15000 2 Video PID Different for each channel leave defaults 3 Audio PID 4 PTMPID 5 PCRPID Page 9 of 23 1 4 Muxer Select 1 Channel Muxer Yes No P Name Digital TV x Not Editable View Only S Name Digital TV x 2 Network Settings Default Value Other Values Notes 2 1 IP Address 192 168 0 136 Any IP address 2 2 Subnet Mask 255 255 255 0 Any Subnet Mask 2 3 Gateway 192 168 0 211 Any Gateway IP address 2 4 Physical Address XX XX XX XX XX XX Unique and fixed for each unit Page 10 of 23 3 Together Settings Default Value Other Values Notes 3 1 System Bitrate xxx Mbit s Edit the Max output Bitrate for system if set too low the video will chop corrupt 3 2 Insert SDT This option turns on off function to change the channel names via the SNMP software Yes No 3 3 Factory Configuration Select ENTER to reset the DCC 200 to its Factory Defaults otherwise select MENU to cancel ENTER MENU Page 11 of 23 6 ADVANCED INSTALLATION Once installed the setup of the DCC 200 is dependent on the level of configuration required e For setups with multiple DCC 200 connected to a network via a swit
5. LACEYS TV User Manual Page 1 of 23 1 TABLE OF CONTENTS 1 TABLE OF CONTENTS INTRODUCTION UNPACKING THE UNIT SETTINGS AND CONNECTIONS INSTALLATION USING THE FRONT PANEL INTERFACE ADVANCED INSTALLATION CONFIGURATION SNMP TECHNICAL SPECIFICATION CONTACT INFORMATION 1 11 16 20 22 Page 2 of 23 2 INTRODUCTION 2 1 Welcome Thank you for purchasing a Laceys TV product This User Manual contains all the information required for the installation of the DCC 200 This User Manual also describes the advanced features and settings of the DCC 200 2 2 DCC200 The DCC 200 is a high quality MPEG encoder that converts Composite Video and Stereo Audio to ASI The DCC200 may be combined with an ASI processor from Laceys tv for digital modulation a COFDM EE Composite Video and Stereo Audio Composite Video and Stereo Audio DCC 200 ast ASI Processor Composite Video w Stereo Audio Composite Video and Stereo Audio Figure 1 The DCC 200 converts up to four Analogue A V Sources into ASI Page 3 of 23 3 UNPACKING THE UNIT 3 1 Items in Box The DCC 200 is delivered with all the necessary hardware and firmware for installation Please check the box for the following items Table 1 List of Items with the DCC 200 Amount Description 1 DCC 200 MPEG 2 Encoder 12 BNC to RCA leads 1 1 7 1 If any item is missing when unpacking please
6. Name Digital TV 1 _Digital TV 1 Digital TV 2 _Digital TV 2 Digital TV 3 _Digital TV 3 Digital TV 4 Digital TV 4 See Chapter 7 for more information about how to change the Provider Name and the Program names Page 7 of 23 5 INSTALLATION USING THE FRONT PANEL INTERFACE The DCC 200 is a standard 1U rack mountable 19 device Laceys TV recommends rack mounting for optimal operation 5 1 Navigation The front panel interface on the DCC 200 uses a simple control scheme Figure 7 Front Panel Layout po bc V Figure 8 Navigation for the DCC 200 Menu Tree Button Usage ENTER Enter Sub Menu Edit Value Save New Value MENU Leave Sub Menu Cancel Editing Right Left Choose Value Up Down Choose Menu Change Value To lock unlock the DCC 200 hold down both the MENU and ENTER button together for a few seconds Page 8 of 23 5 2 Menu Structure The following show the complete menu tree of the DCC 200 Front Panel Interface 1 Channel One Two Three Four Menu Key Name Default Value Other Values Number 1 1 Video Settings 1 Video Standard AUTO PAL NTSC 2 Video Available YES NO 3 Resolution D1 HD1 SIF 2 3D1 3 4D1 4 Brightness 88 0x58 Value out of 255 HEX 5 Contrast 145 0x91 Value out of 255 HEX 6 Saturation 145 0x91 Value out of 255 HEX 7 Hue 0 0x00 Singed 8bit Value HEX 128 to 127 1 2 Audio Settings 1 Audio Bitrate kbit s 384 256 12
7. ch Ethernet connection setup is required e For advanced installations including changing the Channel Names or the Service Provider Name use the software supplied on the CD See Chapter 7 for more information 6 1 Ethernet Connection The DCC 200 operates according to the 10BASE T and 100BASE TX Ethernet standards To connect to the DCC 200 via Ethernet LAN CAT 5e simply use a crossover cable or a switch 6 1 1 Default Network Settings IP Address 192 168 0 136 Subnet Mask _255 255 255 0 Gateway _192 168 0 1 Physical Address Unique to each unit Page 12 of 23 6 1 2 LAN Connection To connect to the DCC 200 over a LAN use the following procedure 6 1 2 1 IP Settings on Windows To edit the IP settings for Windows please first go into Network and Sharing Centre OO ES gt Control Panel Network and Sharing Center Search Tis Network and Sharing Center computers and devices f View full map Connect to a n me Manage wireles works A A amp x Set up a connection or network p LACEYS LAPTOP Multiple networks lanage ne k e This computer Diagnose and repair A Laceys tv Secure Private network Customize Se ect Local and Internet Wireless Network Connection Laceys tv Secure View status Manage Network Co n n e ct i Oo n s Access Limited Connectivity Connection Local Area Connection i Signal strength Excellent Disconnect K Unidentified network Public n
8. etwork Customize EJ Sharing and Discovery Network discovery See also File sharing Internet Options Public folder sharing Printer sharing Figure 9 Network and Sharing Centre select Manage Network Connections Select the Ethernet device connected to the DCC 200 Page 13 of 23 Connectivity Network Category Owner Wireless Network Connection Laceys tv Secure ANAI sea Select the device connected to the DCC 200 Normally called Local Area Connection or alike Figure 10 Network Connections Select the connection that is connected to the DCC 200 Load up the IP configuration Q Local Area Connection Status Marvell Yukon 88E8042 PCI E Fast Ethemet Controller This connection uses the following tems Client for Microsoft Networks IV f QoS Packet Scheduler File and Printer Sharing for Microsoft Networks 1 Select Properties of the B Connection Uninstall nt 2 Open up the properties of the w IP v4 TCP IPv4 Protocol ok J em Figure 11 Connection Status Connection Properties Protocol Properties Page 14 of 23 Edit the Protocol Settings Internet Protocol Version 4 TCP IPv4 Properties You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically
9. he same as in the front panel interface The tabs CH1 CH2 CH3 CH4 are independently set It is easy to set the Video Audio and System Parameters for each channel by changing the tab Page 17 of 23 fee Tosa eee eis Select Channel Figure 15 Main Setting window for the DCC 200 SNMP configuration software on windows NMS 4channel Encoder This window allows the configuration of every setting on the DCC 200 other than its IP address Please note that on some computers the bottom status bar of the NMS Achannel Encoder software may not appear This is typically because the window is too small If this happens please enlarge the window slightly to show the status bar 7 1 Operate To control the DCC 200 connect the PC to the DCC 200 using a crossover Ethernet cable Open the Control Software and select the Operate function top Page 18 of 23 left hand corner on the NMS 4channel Encoder main window to choose or set the IP address to be used To view or change the IP address of the DCC 200 please use the front panel interface Equipment Operate Equipment Name IP Address 4forl Encoder 192 168 0 136 Equipment Name 4forl Encoder IP Address 192 168 0 136 Figure 16 To configure a DCC 200 select its IP address with this window Enter the IP address of the DCC 200 you wish to operate click the smaller tick button to add it to the list Select the IP you wish to use and select o
10. k 7 2 Configuring the DCC 200 Once the correct DCC 200 is selected in the Operate menu and click OK Then return to the main settings menu and press Refresh to load up the current configuration of the DCC 200 If an error occurs then the DCC 200 is not connected to the PC Please refer to Chapter 6 for more information Page 19 of 23 When the settings are configured as needed then click Confirm to send the updated configuration to the DCC 200 To check if the DCC 200 has been updated correctly cycle the power of the unit and then click Refresh and check if the new configuration loads 7 3 Saving and Loading Configuration States The NMS 4channel Encoder has the ability to save and load configuration states To Save 1 Make the changes to the configurations and apply them to the DCC 200 2 Click the Reload button to gain DCC 200 formatted values 3 Click save and name save the file To Load 1 Open NMS 4channel Encoder and Operate the DCC 200 2 Click Open and select open a previously saved configuration file 3 Click Confirm to apply the saved configuration to the connected DCC 200 4 Click Reload to check all values were applied 8 1 Video Input Page 20 of 23 8 TECHNICAL SPECIFICATION Connectors 1x BNC CVBS Standard Composite Video CVBS 8 2 Audio Input Connectors 1x BNC Left 1x BNC Right Standard RCA Audio