Autofill wall mounted water boiler
Contents
1. Autofill wall mounted water boiler Please read and keep these instructions For Burco wall mounted boilers 76700 SKU 444448534 76702 SKU 444448546 amp 76704 SKU444448548 Getting the best from your water boiler e Remove any plastic film from the water boiler before use Any water in the water boiler is due to testing and is normal e The water boiler must be used on a flat level surface e Boil and discard the water twice before general use HELPLINE 2 month guarantee Spares Warranty Important safety instructions The use of any electrical appliance requires following common sense safety rules Primarily there is danger of personal injury and secondly danger of damage to the appliance and property These are indicated in the instructions text by the following two conventions WARNING Danger of personal injury IMPORTANT Damage to the appliance In addition we offer the following essential safety advice General information Scale build up can damage any appliance which boiling water passes through Failure to descale your Burco autofill water boiler will invalidate your guarantee Before general use it is recommended that the unit is boiled and emptied through the tap twice discarding the water each time For best taste and to protect your water boiler from limescale Burco suggest you filter the water supply Location e Do not use your autofill water boiler outside e All sides must be at le
2. LIGHT CAUSE PROBLEM ACTION Green indicator light Power on Amber ready light Flashes when heating up On constantly when up to temperature All lights out Unit may need de scaling be over Contact Helpline boiling or boiled dry PROBLEM Tap is dripping when closed See tap failure guidelines above Helpline 0871 222 2620 Replacement Parts IMPORTANT This product has no user serviceable parts IMPORTANT Installation must be carried out by an appropriately qualified service engineer Any damage caused by installation by an unqualified individual will invalidate you warranty Genuine replacement Burco parts must only be fitted by a qualified service engineer If generic non Burco parts are fitted you may stop your autofill water boiler operating safely and in the most efficient manner and may invalidate your warranty Helpline 0871 222 2620 If you have any difficulty with your appliance please check the items on the list below e Does your autofill water boiler have power going into the unit e Have you tried descaling your autofill water boiler e Have you pressed reset button If you are still having trouble with your appliance please don t hesitate to call us Please try to have your product to hand and have the following information ready to enable us to deal with your query quickly e Name of the product e Model number as shown on rating plate located on the side of the unit e Serial number as loca
3. element is fitted with a manual resettable thermal cutout which protects the water boiler from damage if it were to overheat D If your appliance fails to heat up and or appears dead when switched on try the following Check the water boiler is plugged in to the mains and switched on both at the plug spur and the front of the unit If this does not resolve the problem switch off and disconnect the appliance Remove the front panel see instructions below and remove internal cover below the water tank Reach in carefully and on the underside of the element between the two terminals you will see a reset button Press this upwards and the thermostat will reset click We would always recommend descling the water boiler after resetting the thermostat as scale build up is the most common reason for the safetey thermostat operating If the safety thermostat activates repeatedly even after descaling please contact the customer helpline After resetting the cut out replace the front panel and top plastic lid Reconnect to the mains and switch on at plug spur and on the front of the unit If the problem pursists please contact Burco customer helpline Cleaning WARNING Disconnect from the electrical supply before cleaning and allow the water boiler to cool IMPORTANT Do not immerse the water boiler in water or any other liquids and take care to keep water away from the mains lead and connections There are two ways in which you will need to c
4. have a pressure not exceeding 1000 kilopascals 10 bar and no lower than 25 kilopascals 0 25 bar If your water pressure exceeds this a suitable pressure reduction value will need to be fitted Please ensure that you follow the bye laws of the water council when installing this product Burco cannot be held responsible for water boiler malfunction if the water supply pressure does not confirm as above If in any doubt consult your water supply company The hose supplied with the water boiler is manufactured from materials which have been approved for drinking water and is rated at 10 bar at ambient temperature It is therefore recommended that the water boiler is only connected to a cold water supply Your guarantee could be invalidated and water contamination may occur if a hose not supplied by Burco is used Please note that washing machine hoses are not suitable for use on this water boiler Connection to mains water supply eosesosososoooe sesosososocoso eesossososososocososooososoocooooososososooe Your autofill water boiler can be set up so that the mains water connection can either enter your water boiler at the back or the bottom of the unit To set up connection from back of unit e Using a screw driver remove blanking plate from back of unit EX e Attach supplied water connection fitting to water inlet screw fitting and when secure attach the pipe E e Tightly attach other end of water connection hose to m
5. must be connected to the terminal which is marked with the letter L or coloured red or brown Make sure that the connections are tight and that there are no loose strands of wire and no insulation trapped under the terminals Tighten the 3 clamp in the plug making sure that it grips the outer covering of the cord Ina 13A BS 1363 fused plug fit a 13A fuse Tighten the plug cover securely If you are in any doubt consult a qualified electrician IMPORTANT The supply cord on this appliance is of a special type If replaced only a Burco supply cord must be used The supply cord may become warm when the appliance is in use Features 1 Removable lid Easy access for descaling 2 Removable front cover 3 On Off switch 4 Safety locking tap 5 Hose for connection to drinking water Preparation 1 Remove any plastic film from the water boiler and wipe over all surfaces with a clean cloth 2 Check that the voltage on the rating plate of your appliance corresponds with your electricity supply which must be A C Alternating Current 3 Before using it is recommended that the water boiler is boiled twice discarding the water each time Check list Before starting installation check that you have the following parts e Autofill water boiler e Drip tray e Food safe hose Connecting to a water supply Your water boiler has been supplied with a suitable hose E for connection to a drinking water supply The water supply must
6. ains water supply e Ensure all pipes are suitably insulated to prevent water supply from freezing e If rear overflow is required see instructions below on how to set this up at this point To set up connection from bottom of unit e Using a screw driver remove blanking plate from back of unit EN e Attach supplied water connection hose to water inlet with the elbow joint connection on the hose screw fitting f e Tightly attach other end of water connection hose to mains water supply e Replace blanking plate Overflow Connecting rear overflow An air gap of 200mm from the connection point must be provided Failure to provide this air gap will cause an air lock and stop the water discharging in event of an overflow IMPORTANT For rear overflow connection a 14mm internal diameter hose or a 15mm internal diameter hose with a pipe clip must be used While every reasonable precaution is taken to prevent an overflow Burco cannot be held responsible for any damage caused as a result of incorrect installation or blockage of the overflow e Attach a suitable 14mm internal diameter or 15mm internal diameter hose with a pipe clip to outlet connection Hose not supplied e Attach other end of outlet hose to mains drain If connection to the bottom of the water boiler is desired now replace the blanking place at the back of the unit using screw driver to tighten in place Wall mounting your autofill water boiler e Before wall m
7. ast 100mm from any walls e Ona flat level surface Ambient Temperature This appliance is designed to operate in an ambient temperature between 10 C and 40 C Mains lead e The mains lead should reach from the wall socket the autofill water boiler without straining the connections e Do not let the cord hang over the edge of the table or the counter and keep it away from any hot surfaces e Do not let the lead run across an open space e g between a low socket and table e Do not place the autofill water boiler where the mains lead could fall into a sink Your safety WARNING Extreme caution must be used when moving the autofill water boiler as it is very heavy e Do not continue to use the water boiler if the warning lights are flashing consult advance diagnostics service light warning codes e Do not use boiler if it has been damaged in any way e Do not place the appliance on or near hot surfaces e Donot use accessories or attachments which Burco have not recommended as they can cause hazards e Always switch off empty and disconnect the autofill water boiler before moving the unit WARNING The only parts you should touch behind the front panel are the two red isolation valves and the reset button WARNING To avoid being scalded when the water boiler is in operation or has just been switched off keep hands away from any steam Be particularly careful not to touch any hot surfaces especially when running the descale pr
8. drain the tank again 10 Reasemble your appliance refitting the front cover tank cap and lid Your appliance will now operate normally 8 In hard water areas where a large build up of scale has formed you may need to remove the tank lid and physically scrape the scale from the tank and level sensing probes If this is required ensure care is taken not to damage the level sensing probes Tap failure e Scale build up can cause your tap to drip when it is in a closed position If your tap should fail to operate follow the procedures below e Remove front panel of unit See procedure on page 8 WARNING The only parts you should touch behind the front panel are the two red isolation valves Touching any other part will put you in danger of receiving an electric shock e Isolate tap by turning tap isolation valve clockwise e Unscrew the top of the tap from the body of the tap e If scale is present white yellow chalky substance wipe scrape and break the scale away from the rubber flexible seal and also from the sealing surface inside the body of the tap e Replace top of tap screwing it firmly back into the base Open the isolation valve behind tap If dripping has stopped replace front panel and follow descale process see page 8 If tap continues to drip call the Burco customer helpline IMPORTANT Failure to de scale will invalidate your guarantee Trouble shooting Indicator light warning codes INDICATOR
9. lean your autofill water boiler Externally to do this follow the external cleaning guidelines on page 8 Internally to do this follow the Easy Descale Procedure on page 8 IMPORTANT Do not use any abrasive cleaning fluids or materials Reset button External cleaning guidelines WARNING Always disconnect the plug from the mains and allow to cool before cleaning To clean wipe the outside of your autofill water boiler with a damp cloth It is recommended that this is done daily Stubborn stains may be removed using a good stainless steel cleaner or non abrasive cleaner Hard to reach areas should be cleaned using a small bristle brush and mild cleaner IMPORTANT Do not use abrasive cleaners on your water boiler as this could scratch the finish of your water boiler To remove front panel of unit e Remove black plastic lid i e Using screw driver remove two retaining screws e Lift front panel slightly to disconnect front panel at top of the curved front panel so that hole for the tap goes over the lower part of the top and lift vertically over the rest of the tap Hi e Pull front panel forward while lifting hole for tap over base tap fitting e Lift front panel over top of tap fitting WARNING When replacing the front of panel ensure that wires do not get trapped between tap and front panel Easy descale procedure When to descale Burco recommend that its appliances a
10. ogramme or when the front top panel is removed Safety considerations Important do not use a water jet to clean this appliance Important do not use this appliance in an area a water jet can be used Important this applaince is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play witht the appliance Important This appliance is only to be installed in locations where its use and maintenance is restricted to trained personnel e To protect against fire electric shock and personal injury do not immerse cord plug or water boiler in water or any other liquid Do not tamper with the connector in any way If the mains lead is damaged it should be discarded and replaced Turn off and unplug when not in use Maintenance other than cleaning and descaling should be carried out by the manufacturer while this product is within guarantee Contact our service helpline on 0871 222 2620 e Warranty is only valid in the UK IMPORTANT This appliance must only be used for heating water Electrical requirements Check that the voltage on the rating plate of your appliance corresponds with your electricity supply which must be A C Alternating Current For ap
11. ounting your water boiler ensure that the wall you intend to attach it to is sturdy and that there are no electrical cables pipes running behind it e Drill holes in the wall to the following dimensions shown below 3 Litre 150MM T 320MM 7 5 Litre 150MM 1 405MM 15 Litre 150MM T 495MM IMPORTANT Always ensure unit is connected correctly to a water supply and the supply is on before switching the appliance on Operating Safety tap 1 The tap is locked or unlocked by twisting it so that the closed or opened padlock symbol is lined up with the white dot on the tap body General operation 2 There are two open positions one self holding so that the tap remains open and the other self closing so that the tap closes as soon as the lever is released To change the tap position turn the tap lever through 180 3 Open the tap by depressing the tap lever into the horizontal position 4 Close the tap by returning the lever to a vertical position After use Switch off and isolate from supply Water may be left in the water boiler when it is not in use for short periods for longer periods it should be emptied and cleaned out Protective cut out WARNING The only parts you should touch behind the front pane are the two red isolation valves Touching any other part will put you in danger of receiving an electric shock WARNING The protective cutout is only to be reset by a qualified service engineer The heating
12. pliances fitted with a plug If the socket outlets are not suitable for the plug supplied with this appliance the plug should be removed and the appropriate one fitted WARNING The plug removed from the mains lead if severed must be destroyed as a plug with bared flexible cord is hazardous if engaged into a live socket outlet WARNING This appliance must be earthed Should the fuse in the 13A plug require changing a 13A BS 1362 fuse must be fitted IMPORTANT Installation must be carried out by an appropriately qualified service engineer Any damage caused by installation by an un qualified individual will invalidate your warranty Fitting a plug The mains lead of this urn will already be fitted with a BS1363 13A plug In the event of replacing a fuse a 13 amp fuse approved by ASTA or BSI must be used If the plug is not suitable for your socket then the plug must be cut off and disposed of safely An appropriate plug should be fitted as follows IMPORTANT The wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black or blue The wire which is coloured brown
13. re descaled as part of the regular planned preventative maintenance schedule at least every 3 months This may be required more periodically if the appliance is being operated in a hard water area Failure to descale the appliance periodically could cause the appliance to cut out to protect the element in the event of excessive scale build up If the appliance stops heating and all lights on the front of the appliance go out the first thing you should do is to complete the following descale procedure Descaling 1 Switch off the appliance on the front panel 2 Remove lid and prepare for descale e Remove the black plastic lid by lifting up You may need a screwdriver to lever the lid off the stainless casing e Unscrew the large square black cap twist anticlockwise 3 Drain down tank e Take front panel off see instructions above page 7 e Drain the tank through the normal operating tap this will ensure there is still a small volume of water in the tank 4 Pour the descale liquid or powder into the tank 5 Switch on the appliance and allow to fill and boil activating the descle solution This process will take approx 40 minutes 6 Switch off the appliance 7 Drain down the tank completely using the tank drain down valve Connect a hose supplied to the drain valve and drain into a vessel or drain to dispense of the water 8 CLOSE THE DRAIN VALVE 9 Fill the tank with fresh water through the plastic cap on top of the unit and
14. ted on the rating plate located on the side of the unit Guarantee This water boiler is guaranteed for a period of 12 months from the date of purchase against defective materials or faulty workmanship This guarantee is given subject to the water boiler being used in accordance with the instructions on the supply voltage marked on it and to the usual fair wear and tear conditions The guarantee does not cover consequential damage arising out of any failure acceptable under guarantee nor does it cover damage resulting from misuse accident or unauthorised alterations to the water boiler This guarantee in no way diminishes the buyer s statutory rights 10 Notes 11 Burco products are intended for commercial use as detailed in these instructions Burco has a policy of continuous improvement in product quality and design The Company therefore reserves the right to change the specification of its models at any time SxS GO
Download Pdf Manuals
Related Search
Related Contents
USER GUIDE - Soundcraft Mitsubishi Electric OL-XL7100TZ projection lense - UnatSolar laboratory for the generation, protection, control and distribution of manual tecnico Samsung MH026FSEA User Manual Operating Manual Manual de instrucciones Manuel d`utilisation MVI56E-MNETR Set-Up Guide Triarch 31125 User's Manual Copyright © All rights reserved.