Home

COOL MIST HUMIDIFIER

image

Contents

1. with warm water until the bleach smell is gone STORAGE INSTRUCTIONS 1 Clean unit thoroughly according to instructions and allow to dry completely before storing 2 Store unit in an upright position away from sunlight Do not store in temperatures below 41 F ONE YEAR LIMITED WARRANTY PERFECT AIRE warrants that during the first year from the original date of purchase this product will be free from defects in material and workmanship Perfect Aire at its discretion will repair or replace this product or any component of this product found to be defective during the warranty period This is a one time replacement warranty If the product is no longer available Perfect Aire will replace the unit with a similar model of equal or greater value This warranty is not transferable Proof of purchase is REQUIRED in order to obtain warranty assistance This warranty does NOT cover e Damages caused by improper installation or improper cleaning e Negligent use or misuse of the product e Damages as the result of not using product in accordance with provided instructions e Damage to product walls paintings portraits furniture floor etc as the result of high mineral content in water e Damage to product walls paintings portraits any furniture wood floors etc as a result of improper installation and or cleaning e Use of improper voltage or current e Additional or extended warranties offered by retailers e Disassembly or r
2. Your Source for Home Comfort N Perfect re TABLETOP COOL MIST HUMIDIFIER USER MANUAL FOR MODEL PAU22 Before using your ultrasonic humidifier please read this ae manual carefully and keep gm it for future reference Y F along with your receipt Seg D ae CONTENTS Safety Guidelines escarceos 2 3 Technical Data nacionales aaa 3 BEE EEE 3 Structure Diagram zerrissen ana aida 4 Operating Instructions e Setting up your humidifier ccooccccocnccconncoo 5 e How to use your humidifier coooccccooocccoc 6 Weekly Maintenance Cleaning amp Care T Storage IASTUCIONS ui T CEE A E E ee ee T Troubleshooting ea 8 SAFETY GUIDELINES When using electrical appliances basic safety precautions should always be followed Failure to follow these safety precautions may result in personal injury property damage fire or shock 1 Always have water in water tank when operating unit 2 Use only clean distilled or FILTERED tap water Using tap water with a high mineral content hard water will result in a white dust and the need for more frequent cleanings Hard water can be harmful to unit and may eventually cease its operation Be sure the cap of the tank is firmly tightened Position the unit within the room so the air output from the mist control output nozzle is aimed away from children walls and furniture When removing the tan
3. a firm level surface Do not place unit on overly soft unstable surface towel or wood The humidifier should be placed at least four 4 inches away from all walls and away from heat sources and at least 6 feet from any electronics such as a TV set speakers etc When filling the tank note a Always unplug unit before filling and replacing tank b Distilled or softened water is highly advised Minerals in hard tap water may cause a white dust to appear on furniture and can also eventually cause unit failure c Extreme temperatures can damage unit Water temperatures should NEVER be too hot or too cold Water temperature should fall between 40 F and 90 F d Return tank securely to base before turning on humidifier To turn unit on a Plug power cord into a 110 120V AC wall outlet only b Turn the Power Output Adjustment Knob in a clockwise direction to begin operation of unit c Turn mist output control nozzle to manually adjust mist direction To turn unit off a Turn unit off when desired room humidity is achieved by turning the Power Output Adjustment Knob counter clockwise to the Closed off position b Always turn unit off when water tank is empty c Unit will automatically stop creating mist when water level in base is very low d Do not let water sit in water bottle tank or base for more than 24 hours e Unplug when not in use IMPORTANT Disposing of water in base When dumping water out
4. door partially open 14 DANGER NEVER immerse the humidifier motor unit base in water or other liquids as electrical shock may occur 15 DO NOT use outdoors 16 Turn humidifier OFF if the relative humidity exceeds 60 or if you notice condensation on inside of windows For proper humidity reading use a hydrometer which is available in many retail stores 17 The nebulizer ultrasonic transducer is highly sensitive Keep this important part clean and treat it gently Only clean per instructions WARNING e Do not touch the nebulizer while the unit is operating as possible burns could result e Do not touch the nebulizer with fingers Any residue on the metal will reduce mist output 18 The unit contains no consumer serviceable parts To reduce the risk of electrical shock do not attempt to open the base of the humidifier SAFETY GUIDELINES continued DANGER To reduce the risk of electrical shock this product has a polarized plug one blade is wider than the other As a safety feature this plug will fit into the outlet only one way If the plug does not fit fully into the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to bypass this safety feature Improper use of electric cords and plugs can cause a fire or electric shock hazard NEVER pull on the cord to remove the plug from the outlet Grip plug and pull from outlet Check the power cord and plug for damage A damaged cord o
5. epair by anyone other than an authorized Perfect Aire service center provider e Products used in a commercial setting e Floor display as is models e Damage caused by acts of nature such as hurricane tornado fire etc Incidental or consequential damages caused by breach of any expressed implied or statutory warranty or condition with exception to the extent prohibited by law e Any performance issues that fall outside of the 1 year warranty Note Some states do not allow the exclusion or limitation of incidental or consequential damages This limitation or exclusion may not apply to you DO NOT RETURN THIS PRODUCT TO THE STORE If you have any questions about this product or its warranty please call consumer services at toll free 877 365 6274 T TROUBLESHOOTING Please check the following troubleshooting tips before calling for assistance Problem Reason Soon Plug in unit and turn on the power output Unit not plugged in Power light is off adjustment knob Wall outlet has no power Check the circuit and fuse try another socket Air unit out in cool place for 12 hours without New unit Unit Mist has the tank on the unit eculiar smell j j p The water is dirty or stale Thoroughly clean unit and place fresh water in tank Excessive noise VIDE pe Place the unit on a stable waterproof surface humidifier and surface NE ENGL IN Fill the water tank water tank Water contains high Switch to distilled or filtered wa
6. k use both hands on the tank to grip it securely DO NOT use if tank is cracked DO NOT place the appliance near heating devices such as a stove Keep it out of direct sunlight Keep the cord away from heated surfaces and areas where it can be stepped on or tripped over 8 Use only 110 120V AC outlet Be sure unit is plugged in firmly and completely As with any electrical device plug and unplug unit with dry hands only 9 Turn the humidifier off and unplug the unit when not in use when moving or when cleaning 10 To avoid the risk of fire shock or personal injury do not use an extension cord Warning Never operate unit with a damaged cord or plug 11 Never set on floor Always place unit on a flat level waterproof surface at least 24 inches off floor AWAY from direct sunlight computers or other sensitive electronic equipment DO NOT place the humidifier on wood furniture or other surfaces that can be damaged by water DO NOT place on floor or carpet 12 DO NOT add medication or cleaning products of any type into the mist control nozzle base or water tank See Weekly Maintenance Cleaning amp Care section of this manual for proper instructions on cleaning the unit DO NOT cover block or place anything over any opening NEVER drop or insert any object into any openings 13 The unit should not be left unattended in closed rooms as air could become saturated and leave condensation on walls or furniture Always leave room
7. of the base it is important to pour the water out of the part of the unit as shown in diagram B below so water does not leak into the interior electrical workings of the humidifier and damage the unit Avoid pouring the water out of the base in the direction of the air outlet and protection switch A Top View of Base B Water Dumping Diagram Air outlet Air outlet Water tank shut off S F protection x Water tank Yen switch shut off of base from protection this side switch WEEKLY MAINTENANCE CLEANING amp CARE For optimum performance clean your humidifier weekly according to the following instructions IMPORTANT Unplug the power cord before cleaning e NEVER use any cleaning products solutions which are abrasive corrosive or flammable as these can be harmful to the unit and void warranty if used STEP ONE Scale Removal 1 Fill the base with one 5 oz cup of undiluted white vinegar 2 Let solution stand for 20 minutes 3 With the vinegar in the base clean all interior surfaces with a soft cloth or brush to help remove scales Do not touch the nebulizer with fingers Any residue on nebulizer will reduce mist output 4 Carefully rinse with clean warm water and gently wipe clean STEP TWO Disinfecting 1 Fill the tank with a solution of bleach and water Use 1 2 teaspoon of household bleach in 1 2 gallon of water 2 Let solution stand for 20 minutes shaking vigorously every few minutes 3 Rinse
8. perfectaire us Specification and performance data is subject to change without notice Printed in China
9. r plug must be repaired before using the humidifier TECHNICAL DATA Moder pa FOR HOUSEHOLD USE ONLY zow Output per Hour 3 5 12 7 oz hr All data was tested by the factory and is for Water Tank Capacity 0 8 Gallons reference only 8 20 hrs This product is designed for home use only FEATURES Power Refill Micro Mist Whisper Quiet djustable Auto Shut Off Active Carbon Waterless Operation Output Levels Filter Indicator Ultrasonic Technology Ultrasonic technology is widely used in various domains Water is atomized by ultrasonic sound waves and propelled through the air by a small fan These ultrasonic pulses are silent and produce visible mist that quickly disperses to increase the level of humidity in the immediate area The unit features an easy to clean ultrasonic transducer nebulizer for increased longevity Auto Shut Off Protection Waterless Indicator When the water tank is empty the motor will shut off automatically and Power Indicator Light will turn red Micro Mist Micro mist water particles are smaller than water particles produced by regular ultrasonic humidifiers Benefits of micro mist technology include up to 40 greater output water vapor particles 70 80 smaller for quicker air dispersion 25 greater room coverage and less condensation on and around unit Overload Protection The unit will automatically shut off if a circuit is overloaded 3 STRUCTURE DIAGRAM Fog mouth Water
10. retaining piece Water tank Cap Power cord Power indicator light Upper base Power output adjustment knob Lower base Air inlet Top View of Base Air outlet _ Water tank kr SG nm Ultrasonic Transducer shut off m Nebulizer white circle inside protection black circle at bottom of base switch Pictures for reference only OPERATING INSTRUCTIONS SETTING UP YOUR HUMIDIFIER 1 Carefully pull water tank up to remove it from base 5 Replace the tank cap by firmly turning it clockwise 7 Plug in the unit completely into an adequate outlet See page 3 for technical data 2 Turn the water tank upside down 4 Fill up the water tank with FILTERED or distilled water 6 Carefully return the water tank back to the base Base will partially fill with water 8 Turn unit on by turning the knob clockwise The indicator light will come on and mist will come from the fog mouth The indicator light will turn red when the water tank is empty NOTE Turn the unit off when refilling the tank or moving the unit i nz t Clos Minimum Maximum off mist volume mist volume os i 1 ER Continued on next page OPERATING INSTRUCTIONS HOW TO USE YOUR HUMIDIFIER IMPORTANT NOTES REGARDING HUMIDIFIER USAGE It is recommended that the humidifier base be cleaned before first use See cleaning instruc tions on next page Be sure unit is at least 24 inches off of the floor Place unit on
11. ter clean White dust i i mineral content nebulizer according to instructions Unit too far from end of Move unit closer to edge of table so mist has Damp table or table or too close to floor more time to disperse Do not place unit on floor floor TE MER Tank cap not securely attached or needs replacement No mist Base overfilled Empty base and restart Little mist Mist stuck No water in the water tank Add water to the water tank The power output adj Rotate the power output adjustment knob knob is not turned on clockwise to power the unit on ne MENN Put the humidifier on a flat surface flat surface There is scaling on the Clean the nebulizer transducer according to nebulizer transducer instructions Tank was cleaned with Use fresh water to clean the water tank wrong type of cleaner completely and then let tank dry completely The water level is too low Add water to the water tank The water is dirty or stale Thoroughly clean unit and place fresh water in tank The nebulizer transducer Call Perfect Aire consumer services or fan does not work 877 365 6274 er The room is too small or Turn down the mist volume or turn the unit off wingows OF too humid completely machine Scaling on nebulizer Water is too hard Use distilled or filtered water transducer are Your Source for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 8 7 365 6274 www

Download Pdf Manuals

image

Related Search

Related Contents

Sony SA-W305 Speaker User Manual  Ford 2002 Windstar Automobile User Manual  Klipsch Image S4A (II)    PTRL NV/3 & RXRL NV/3 - RVR Elettronica SpA Documentation  宮城県立がんセンター 非常用発電設備整備他工事 特記仕様書 平成26  Baixar - Coordenação de Serviços Gráficos  Telex IFB-1000 User's Manual  AP 油圧M/C用コイルスプリングコンプレッサー  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file