MNPG89-00 _Pressoterapia Lymphopress 4 ENG_

image

Contents

1. AN Warning In case of not following the instructions the user may suffer from serious injuries Indications N Prohibition indication D This is an indication for not disassembling N Caution ah re In case of not following the instructions the user may suffer from injuries or device damages Pay attention Disconnect the cable from domestic plug Danger Do not use the device in presence of acute inflammations or injuries Infections risk IACER SRL Page 15 di 20 Please consult the doctor in case of cancer intestinal problems fractures acute thrombosis and other invalidating pathologies MNPG89 00 09 05 12 d e MEDICAL DIVISION Do not exceed 20 minutes in the first treatments We suggest to start with treatments of 5 10 minutes Do not use the device if you feel pain or bad feelings Attention do not spill liquids or any substances on the device Liquid penetration could damage the device In case of suspected malfunctioning do Do not connect or disconnect the device not open or repair the device Do not use from domestic plug with wet hands the device Electric shock risk Contact Electric shock risk the distributor or fabricant Use the device only with 220V power Do not press bend or damage the supply Electric shock risk Disconnect electric cable Electric shock risk the device from domestic plug when not in use Avoid to connect more devices to
2. CEI EN 60601 1 e CEO0476 certificate e Equipment not protected against liquids penetration e Equipment and accessories not subjected to sterilization e Use of the equipment is prohibited close to flammable substances or in environments with high concentrations of oxygen e Continuous operating mode equipment e Equipment not suited to be used in external Technical Specifications Power Supply 220 240 VAC Therapy time 50 60 Hz min Current 0205 Max pressure 300 mm Hg SPUREN Max output 25N Weight 2 Kg power Purpose Clinical Purpose Therapeutic Use Clinic and domestic use IACER SRL Page 9 di 20 MNPG89 00 09 05 12 TECH Working instructions 1 Connect cable to the domestic plug 220 240 VAC then turn ON 1 the ON OFF switch 1 2 Wear the applicators a Leggings use i Wear the leggings or single legging and close the zip up to the end then close the retaining Velcro straps in case of wide circumferences legs connect the extensions available as accessories VELCRO ZIP CONNECTION PLUGS PRESSURE PLANTARS i Insert the pressure plantars under the feet available only with double leggings li When wearing the leggings pay attention to position the tubes connection cables in the internal side of each legging in single legging version connection cables position is not important iii Connect 4 tubes to the 4 plugs positioned on each legging paying attention to connect the long
3. product warranty functionality and product safety we recommend to use only original spare parts Warranty Make reference to the national laws for any warranty conditions by contacting the national distributor or directly the manufacturer IACER LymphoPress 4 All rights reserved LymphoPress 4 and menen owision 70905 are owned by LA C E H Srl and are registered IACER SRL Page 19 di 20 MNPG89 00 09 05 12 I A C E R S r l SU Sede operativa 30030 Martellago VE Via S Pertini 24 A Tel 39 041 5401356 Fax 39 041 5402684 Sede legale S Marco 2757 30124 Venezia Cod Fisc P IVA IT 00185480274 R E A VEN 120250 M VE001767 Cap Soc 110 000 00 i v w w w iacer ve it iacer iacer it
4. progressive pressure Lymphatic drainage Lower limbs relief and comfort Substances stagnation prevention in peripheral tissues Blood insufficiency prevention caused by an inadequate pump action Muscle tone loss in disabled or paralyzed patients Compressive limbs therapy substitutes the manual massage for trophic purposes Page 5 di 20 MNPG89 00 09 05 12 I TEGR MEDICAL DIVISION Machine body and accessories Nea AIR DISCHARGE OUTPUT 5 PRESSURE ADJUSTEMENT 4 ELECTRIC CABLE 7 EXTENSIONS FOR LEGGINGS 10 1 DERIVATION CONNECTION TUBES 8 PRESSURE PLANTARS 9 DERIVATIONS CONNECTION TUBES FOR LEGGINGS 13 SPECIAL SPLITTER FOR SIMULTANEOUS THERAPY ON BOTH LEGS AND ABDOMINAL BAND IACER SRL Page 6 di 20 MNPG89 00 09 05 12 psi e MEDICAL DIVISION Accessories size Legging e Length around 76 cm from upper side to heel e Thigh circumference around 65 e Ankle circumference around 38 cm Armband e Max length around 86 cm e Biceps circumference around 50 cm e Wrist circumference around 36 cm Abdominal band e Abdominal around 136 cm e Height around 46 cm e Velcro height around 31 cm Extensions e Max width around 13 cm e Min width around 6 cm IACER SRL Page 7 di 20 MNPG89 00 09 05 12 E3 e MEDICAL DIVISION Configurations Lymphopress 4 can be supplied in 5 different versions LYMPHOPRESS 4 TOT compressive limb therapy system com
5. MEDICAL DIVISION User manual MNPG89 Rev 00 Edition 09 05 12 Pressotherapy model LymphoPress 4 mi MEDICAL DIVISION I A C E R Srl Via S Pertini 24 A 30030 Martellago VE ITALY Tel 041 5401356 Fax 041 5402684 e mail iacer iacer it http www iacer it psi e MEDICAL DIVISION C 0476 MDD 93 42 EEC Compliance E3 e MEDICAL DIVISION Summary Summary Pressotherapy Machine body and accessories Accessories size Configurations Specifications Specifications Technical Specifications Purpose Working instructions Troubleshooting Warnings Cleaning Maintenance carriage and storage Disposal Assistance opare parts Warranty IACER SRL Page 4 di 20 cO O O O N SD dd KA 14 15 18 18 19 19 19 19 MNPG89 00 09 05 12 MEDICAL DIVISION Pressotherapy Compressive limbs therapy is able to promote a right venous circulation by decreasing muscle tension caused by stress or chronic and acute pains thanks to its pump action it favorites venous return by increasing tissues blood circulation and finally their physiological renewal Compressive limbs therapy can solve blood stagnation problem in damaged sanguine vessels or in body zones not correctly bedewed External compression allows excess interstitial fluids to return in circulatory system in order to be quickly removed Most co IACER SRL mmon applications are Body massage increase Blood flow promotion thanks to a slow and
6. egging paying attention to connect the longer tube to the higher position connector darker color of legging thigh iv After connecting the tubes to the relatives leggings connect the tube to the splitter connected to the air discharge output 13 v Wear the band and connect the tubes to the band plugs paying attention to connect the longer tube to the higher position connector on abdominal band vi After connecting the tubes to the band connect the tubes to the splitter connected to the air discharge output 193 c Armband use i Wear the armband and connect the tubes to the armband plugs paying attention to connect the longer tube to the higher position connector darker color on armband ii After connecting the tubes to the armband connect the tubes to the air discharge output 5 IACER SRL Page 12 di 20 MNPG89 00 09 05 12 TEGO 3 Therapy time selector 2 on machine body a Therapy time can be adjusted from 0 to 30 minutes pump motor of main body will start operating b The air will fill up in applicator chambers in 2 minutes Attention The time selector cannot be moved counterclockwise during the treatment Please wait the session end to adjust a new therapy time 4 Pressure regulator selector 3 on machine body C Air pressure in compression chambers can be adjusted from 0 to maximum pressure around 300 mmHg 20 by rotating the knob in clockwise a Start the treatme
7. er tube to the higher position connector darker color of legging thigh IACER SRL Page 10 di 20 MNPG89 00 09 05 12 I TEGR MEDICAL DIVISION iv After connecting the tubes to the relatives leggings connect the tubes to the air discharge output 5 b Abdominal band use CONNECTION PLUGS di i Wear the band and connect the tubes to the band plugs paying attention to connect the longer tube to the higher position connector on abdominal band li After connecting the tubes to the band connect the tubes to the air discharge output 5 b Simultaneous use of double leggings and abdominal band r t f i Connect the special splitter for simultaneous therapy 13 to the air discharge output 5 Then connect double leggings and abdominal band connectors to the splitter IACER SRL Page 11 di 20 MNPG89 00 09 05 12 lea Be LIA r Q MEDICAL DIVISION ii Wear the leggings or single legging and close the zip up to the end then close the retaining Velcro straps in case of wide circumferences legs connect the extensions available as accessories ili Insert the pressure plantars under the feet available only with double leggings iii When wearing the leggings pay attention to position the tubes connection cables in the internal side of each legging in single legging version connection cables position is not important iv Connect 4 tubes to the 4 plugs positioned on each l
8. ice does not need a particular regular maintenance Carriage precautions It doesnt need any particular carriage precautions however we recommend to put away Lymphopress 4 and its accessories in their own box after every treatment Storage precautions Lymphopress 4 is protected till following environmental conditions Outside of the packaging temperature from 5 to 40 C humidity from 30 to 80 pressure from 500 to 1060 hPa Inside of the packaging temperature from 10 to 55 C humidity from 10 to 9096 pressure from 500 to 1060 hPa IACER SRL Page 18 di 20 MNPG89 00 09 05 12 e MEDICAL DIVISION Disposal The equipment is subjected to WEEE regulations see the symbol X on the label concerning separate waste collection when disposing this product please use the designed areas for disposing electronic waste or contact the manufacturer Assistance Every intervention on device must be performed by manufacturer For any assistance intervention contact the national distributor or I A C E R S r l Via S Pertini 24 a 30030 Martellago VE ITALY Tel 041 5401356 Fax 041 5402684 You can get any technical documentation on spare parts but only prior business authorization Spare parts Contact the distributor or the fabricant for original spare parts at following address Il A C E R S r l Via S Pertini 24 a 30030 Martellago VE Tel 041 5401356 Fax 041 5402684 To preserve
9. nt with a middle pressure and increase it progressively according to your needs IACER SRL Page 13 di 20 MNPG89 00 09 05 12 E3 e MEDICAL DIVISION Troubleshooting LymphoPress 4 doesn t switch on LymphoPress 4 emits a strange sound like air leakage There is no pressure or the air doesn t go into the applicators Air goes into the compression chambers and or an air leakage is present in the applicators Check the connection to the domestic plug Check the ON OFF button Check the power supply status no sign of damages Check if there are any damages and or holes in the tubes and connectors Check the applicators right connection to the main body Check if the tubes are pressed or bent Check the applicator right connection to the main body Check if the tubes are pressed or bent Check if the compression chambers swell up in a progressive way Check if there are any holes or damages in the compression chambers If there are not any air leakages switch off the device then switch on it and re check the right working ATTENTION with Lymphopress 4 double leggings version always connect both leggings to the connection tube even if you use only one legging during the treatment IACER SRL Page 14 di 20 MNPG89 00 09 05 12 e MEDICAL DIVISION Warnings The following warnings guarantee user safety and prevention against damages and or lesions Please read it carefully before using LymphoPress 4
10. prising machine body double legging 6 2 derivations connection tubes 9 2 pressure plantars 8 armband 11 abdominal band 12 1 derivation connection tubes 10 special connector for simultaneous therapy on both legs and abdominal band 13 LYMPHOPRESS 4 LEG2 ABD compressive limb therapy system comprising machine body double legging 6 2 derivations connection tubes 9 2 pressure plantars 8 abdominal band 12 1 derivation connection tubes 10 special connector for simultaneous therapy on both legs and abdominal band 13 LYMPHOPRESS 4 LEG2 compressive limb therapy system comprising machine body double legging 6 2 derivations connection tubes 9 2 pressure plantars 8 LYMPHOPRESS 4 LEG1 compressive limb therapy system comprising machine body single legging 6 1 derivation connection tubes 10 LYMPHOPRESS 4 ARM1 compressive limb therapy system comprising machine body armband 11 1 derivation connection tubes 10 Extensions for wide legs 7 and special connector for simultaneous therapy on both legs and abdominal band 13 are available as accessories Single accessories are available as optional to complete Lymphopress 4 content and potentiality IACER SRL Page 8 di 20 MNPG89 00 09 05 12 e MEDICAL DIVISION Specifications Lymphopress 4 has the following specifications e Class lla equipment Directive 93 42 EEC annexed IX rule 9 e Class ll applied part type BF Classif
11. the Avoid device hits or drops same multiple plug Overheating risk IACER SRL Page 16 di 20 MNPG89 00 09 05 12 L 4 vw 6 qa n L LU MEDICAL DIVISION a Caution Do not move when the device is working Do not expose the device to the sun and do not storage it next to heat sources Do not place any objects on the device or If you not use the device for a long time or on its parts connector tubes applicators if you use the device in cold places a etc malfunctioning may happen make it operating by changing progressively the intensity for 3 4 times Clean the device using a dry soft cloth Do Do not bend or tie the connection tubes not use cleaning solvents or other chemical substances in order to avoid any damages Leh Use the device only for expected Product subject to WEEE regulations purposes concerning separate waste collection of electronic equipment IACER SRL Page 17 di 20 MNPG89 00 09 05 12 e MEDICAL DIVISION Cleaning Clean the device and its accessories using a soft cloth Resistant stains can be removed using a sponge soaked in solution of water and mild soap Wait for the complete drying before using the device and its accessories Do not use chemical substances solvents or cleaners to avoid device and accessories damage Maintenance carriage and storage If it is used in accordance with the instructions of the user manual the dev