1. 175 25 12 X 0 Y 0 Discard Modification Apply 1 Preset point setting Set up the arrow key direction control Press the HOME key to return to the origin 2 Coordinates of the system Negative coordinates to the left and positive the right e Press the Go button after the X and Y coordinates are given to move the system to position defined by the coordinate value Current position of the system will show in the coordinates bar which changes with varying console locations 3 Default position setup PO1 P15 Press any of the fifteen keys PO1 P15 to save current X and Y coordinates in it Keys with preset coordinates are marked with saved position Press button P1 P2 and on your remote controller to move the system to location predefined by them 4 Set up patrol route in the Preset route setting window a Route No Select the code of the route you want to set up in Route No field You have three options ROT R02 and R03 b Select position to stop at Every route can have 15 positions to stop at You can define time to spend at each position in unit of minutes seconds c Total span of time for each patrol in Patrol duration field Set up total time of each patrol Once the time expires the patrol stops and the system back to its origin Note Your changes become effective only after you press the Apply button If you press the Discard button instead
2. 100 Auto Tracking System User Manual English AREC Inc All Rights Reserve d 2013 www arec com All information contained in this document is Proprietary 100 User Manual SS Auto Tracking System Your AREC TP 100 auto Tracking System can work with different cameras for vertical and horizontal tracking It may track shooting lecturers target in indoor environment when accompanied with a compact Locator AREC AM 500 In addition to online device setup the AREC Auto Tracking System features both auto and manual tracking modes for even greater user conveniences The best choice tracking recording device indeed AREC AM 500 wireless microphone positioner AREC TP 100 Auto Tracking System 100 User Manual zz Table of Contents 1 PRODUCT TINIE t 3 2 GETTING TO KNOW YOUR PRODUCT 000 4 3 LIGHT INDICATORS OF YOUR 4 WIRELESS MICROPHONE LOCATOR 7 5 LIGHT INDICATORS OF YOUR AM 00D 8 6 HOW TO INSTALL YOUR SYST EIVI serene retta rra rutru perenne pne hene raro rona 8 7 HOW TO ENABLE THE AUTO TRACKING FUNCTION 10 8 HOW TO INSTALL A NETWORK CAMERA ssssm IHR 12 9 THE TP TOO MANAGEMENT WEB PAGE ttn reme rr
3. 1 3 Light indicators of your TP 100 Light indicator displays its function and status and signals something is being tracked Light indicator Status The light turns green after power ON It flashes green when something 18 being Power Indicator Red and green tracking Flashing orange means firmware update is ongoing The light flashes blue when 100 5 network connection is working well TP 100 Network Indicator Network Indicator of The light flashes blue when the network the Network Camera camera is working normally 4 Wireless microphone locator information AREC TP 100 can work with the AREC wireless microphone an exclusive locator for concurrent lecturing and tracking shooting When the person wearing the microphone moves the TP 100 would follow its movement without interruption by other moving objects Mute button and light indicator Stop tracking button and light indicator o Power switch and light indicator o Wireless microphone pairing light indicator 5 3 5 audio input jack 100 User Manual NENNEN 5 Light indicators of your wireless microphone Light indicator of your wireless microphone displays its function and status and signals pairing status with the KS 700 AREC wireless microphone Light indicator Status A Upper front Auto tracking function suspense Red light flashes when pressing and holding the O Lower front button to switch network status bet
4. 10 The administrator web page The administrator web page displays with three tabs Main Patrol Setting and Manual Control Panel The Main setup page Laco Auto Tracking System Main Manual Control Panel Control Panel Device Info Installed Direction Logo Upright Camera above Tracker 2 Device Name rP100 go Upnght T Logo Upside Down Tracker above Camera MACBC BA E1 01 00 15 Auto Tracking Setting Language Engle D Firmware VersionV01 04 4 Enable Auto tracking Enable Tilt Vertical 3 Firmware Update ST SS ff iti fi 50 Ri ARDER Submit Offset Position Define pan Left 50 50 Right Offset Position Definetil p Down 20 20 Up New User Name PM Sensitivity 9 12 meter v 4 New Password 8 GEnable target missing compensation Need to work with KS 700 Confirm Password Object missing tolerance Export Configure Export Full view sustaining period 5 Import Configure Environment Setting Sunlight Mode SHES Network Setting RS 485 Settings DHCP Protocol Pelco D v 6 rotoco LII d IP Address 192 168 1 100 BaudRate 9eo0 v 9 Subnet Mask Default Gateway Discard Modification Apply 1 Change language Traditional Chinese Simplified Chinese English 2 Device Name Name your device for easy identifying when used together with KS 700 or IP address searching 3 Firmware update Select the software to update with the
5. 3 IP 192 168 1 1XX in Use the following IP address field Figure 1 Enter the static IP address of your TP 100 192 168 1 100 in your browser s URL bar Figure 2 The login page displays Enter account ID and password admin admin for the first time You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 192 Subnet mask 255 255 255 0 Defauit gateway Figure 1 lt gt QC 192 168 1 100 Figure 2 Note If you failed to enter the setup page try several times by repeating the above steps If the problem persists connect your TP 100 to a router discover it by scanning with the Device Search utility contained in the included DVD ROM After the new IP address of your TP 100 is acquired set the first three number of your computer s IP address to the same as that of the newly found IP address of your TP 100 open up your network browser type in the newly found IP address of your TP 100 and it should work now 2 Connect via KS 700 1 Connect the TP 100 to KS 700 enter this web page from the management interface ALCS Home Language System Administration User Password 12 100 User Manua
6. changes you made are deleted 17 100 User Manual Se Manual control page amenan HAZE KNEE 6 1 Tracker moving speed 501 Press the arrow key once to move SOT distance S02 Press the arrow key once to move S02 distance 503 Press the arrow key once to move S03 distance S04 Press the arrow key once to move S04 distance Unit distance S01 S02 S03 S04 the greater the number is the faster the TP 100 is scanning 2 Manual direction control panel Press the arrow key to change direction Press HOME key to back to the origin 3 Test the patrol route Click any one of the three patrol routes 1 to start the test and press the Stop button to stop testing 4 Start patrol during shooting e If only one route is defined for code RO1 RO2 ROSG you can start it by pressing the Patrol key in the remote controller to start it f more than one route are defined for code RO1 RO2 ROS the Please choose the route to patrol window displays after the Patrol key in the remote controller is pressed Select the desired route in it e The console back to its origin after each patrolling Setting gt Patrol 5 PO1 P15 test Press any of these 15 keys to test the preset patrolling point 18 ATCC TP 100 User Manual 11 How to setup auto full view function When TP 100 cannot s
7. direction installation if your TP 100 is ceiling mounted or it may move opposite to your instruction when operating it manually 8 Auto tracking setup a Check Uncheck the Auto tracking box Switch off auto tracking when you would like to control manually without any interference b Check Uncheck the Enable Tilt box Switch off tilting movement to fix TP 100 only do horizontal tracking and improve the stability C Offset position define Set up offset rate for tracking positioning in range from the left most 50 about 6 degree from central to the left to the right most 50 about 6 degree from central to the right d Tracking sensitivity Set to the highest sensitivity and the TP 100 starts tracking with the lecturer s slight swing and the lowest sensitivity to start tracking only when the lecturer moves significantly Adjust the parameter by selecting the right distance range between TP 100 and the lecturer e Enable target missing compensation Enable the function could make TP 100 change to the preset full view automatically while the tracking target is missing or out of TP 100 s view range This function ensures the camera could always have shooting target inside the view Object missing tolerance period the compensation mechanism would not be triggered during the tolerance period Full view sustaining period The tracking would not be activated during the full view sustaining period Above two settings are designed for avoiding the view
8. following steps i Press the Open file button and the File selection window pops up ii Press OK after located the target software update in its original storage path iii Name of the software file displays in your Main setup page iv Validate the file name press the Upload button to start software updating v The power light indicator of TP 100 flashes orange during software updating vi Once the update is completed the power light stops flashing to turn to steady green and the TP 100 back to its original position Note Your settings remain intact after software update 4 Change user name and password You can change the default user name and password admin and admin at your wishes 5 Configurations Import Export Press Export button to save all the setting data into assigned folder e Press Open file button to select the file you want to import into this device Press OK and Import button to finish the import process 6 Installed direction Select to install your TP 100 in upright direction e g installed on a tripod or upside down direction e g ceiling mounted Set up the upside down direction installation if your TP 100 is ceiling mounted or it may move opposite to your instruction when operating it manually 15 100 User Manual es EE 7 Installed direction Select to install your TP 100 in upright direction e g installed on a tripod or upside down direction e g ceiling mounted Set up the upside down
9. 0 network setting from DHCP to fixed IP 192 168 1 100 and the indicator would show green while restarting Network Setting DHCP IP Address 192 168 1 100 Default Gateway 92 1681 1 21 100 User Manual es 33 Appendix The optimum installation environment 1 TP 100 is applicable in an indoor environment An indoor environment can be any place without direct or indirect sunlight Take example Windowless room No sunlight through the door If so please close the door Room with curtains and the curtains are completely closed Curtains of cotton linen silk and other opaque materials function the best Indoor lighting Ceiling mounted fluorescent tubes The ceiling must be at least 2 5 meters high and without any spotlights or downlights of yellow light source Wall surface behind the target blackboard or whiteboard Without night vision monitoring device in existence 2 Optimum space for the use of TP 100 capable of faultless tracking Space dimension 8m L x 5m W x 2 5m H Proper installation position of TP 100 the best tracking distance 4 7 meters away from the target object Faultless tracking Nothing stands in between AM 500 and TP 100 e g the target turn around Once the target is lost the TP 100 can detect the target again in 3 seconds automatically 3 Other conditions e TP 100 should be installed in open space without a
10. bottom of your TP 100 may thus fail to fully snap to it and lead to vibration during panning or tilting and in turn poor recording Please use hanger with larger screw locking place Note 2 Recommended installation position 4 7 meters away from the object being tracked 10m 10m a p d s l s y s 1 b 1 4m 2 7m 2 7m 4 P X 7m Fa s N 4 s l d 9m M 9m 7 How to enable the auto tracking function 1 Connect your TP 100 to power source and the 2 Insert the battery in your AM 500 power it ON by green power indicator lights up pushing the power button to the ON position the green power indicator lights up briefly then turns off 3 Fix your AM 500 to the target person or object properly After your AM 500 is detected by your TP 100 its power indicator flashes and it follows the movement of the person WE ko s gs Note Fix your AM 500 with the metal back clamp and lanyard when wearing it for better tracking effect effect 100 User Manual 8 How to install a network camera 1 Pull open your TP 100 s QUICK SHOE lock 2 Lock the QUICK SHOE to network camera s remove the QUICK SHOE standard screw holes by referring to directions shown in QUICK SHOE s instruction label 3 Pull open your TP 100 s QUICK SHOE lock insert the network camera until the lock snaps back to its original position 4 Prepare the po
11. changes too many times or too often and make viewers confusing f Environment Setting Adjust different modes based on different tracking environments Default mode Suitable for simple indoor environment without sunlight pass through e Sunlight mode Suitable for the environment rich in IR interference 9 Network setup DHCP options Select to assign IP address by router e Manual IP address setup Give IP address subnet mask and default gateway manually Note Your changes become effective only after you press the Apply button If you press the Discard button instead changes you made are deleted 16 TP 100 User Manual A Patrol setup Laco Auto Tracking System English v Patrol Setting Manual Control Panel Preset Point Setting Preset Route Setting a Route Number RO1 4 Patrol Duration 4 0 hh mm ss INE TNI 11 5 mm ss 0 mm ss 5 0 0 mms 5 mm ss 0 mnvss 5 mm ss 0 5 mm ss 0 Push below buttons to save the positio Po X 0 Y 0 P04 5 mm ss P03 X 175 Y 35 mnvss 0 mm ss 0 mm ss None v 4 0 mm ss X 0 Y 10 P07 X175 Y 25 P10 P13 2 3 4 5 6 7 8 9
12. ee the tracking target the video will take useless scenes without any lecturer or teacher inside Therefore we could suggest users to activate auto full view function to cover this problem This function MUST be set in AREC KS 700 Media Station web page and work with KS 700 to get a better performance Here is the instruction about how to setup auto full view function 1 Log into KS 700 administrator web page and go to Sensor Setting page Find auto tracking system and double click to get the device setting page Refresh System Information Sensor Setting Network Setting Record Setting Local Storage Setting Layout Manager Lecture Manager Photo Manager Event Log About Auto Tracking Mount Add Manufacture Name IP Address MAC Administrator Password Sumt Following Speed Speed 1 J Preset Setting P01 M Save P01 P2 P04 pos po P07 Pos Po P10 P12 pig p4 pi Language Log out System Administration AREC TP100WAN 192 168 0 106 1 01 00 admin 2 Using direction keys and zoom in out bar to get a close up shot 3 Choosing as the Preset Point and click Save button Preset Setting P01 19 TP 100 User Manual 4 Moving the zoom out bar to get a full view shot 5 Choosing Ful
13. l 2 Click sensor setup in your KS 700 management page System Administration System Information Sensor Setting Video Sensors Sensor Setting CH1 c Computer Document Cam Camera Choose PT Scanner Choose PT Scanner Choose PT Scanner Record Setting Local Storage Setting Layout Manager Audio Sensors Lecture Manager 3 The search page displays Click the Auto Tracking System tab and the Auto Tracking System information page displays her TA EZHBERIS Auto Tracking Mount Refresh Add 13 100 User Manual ee 4 Click Advance and the system login page pops up Type the default account ID and password admin and admin and the Auto Tracking System management page displays Language Log out System Administratio PESI Jii Manufacture AREC Inc Sensor Setting Model 100 IP Address 192 168 11 90 Network Settin g MAC BC BA E1 01 00 02 Record Setting Administrator admin Password sess Local Storage Setting Submit Layout Manager Pan X axis Lecture Manager u ui Pan axis Event Log Following Speed Medium x lt 8 93 Sensitivity Medium About T M v Save Preset Setting P01 System Administration User Name fan Password 14 100 User Manual es 1
14. l View point as the preset point and click on Save Preset Setting Full View v Save 6 The setting completed You could click button below to check the close up shot and Home button which in the direction keys to check the full view setting m Preset Setting P01 o2 poe C LOB HEHE 7 Log into 100 administrator web page and check if the function already activated V Enable Full View Mode Need to work with K5 700 Activate Lead time 2 sec Full view sustaining 5 sec 20 100 User Manual 12 How to do when you forget the IP address Sometimes you may need to get access to the administrator web page but just forget the IP address witch set by you or someone else AREC TP 100 provides you a solution to solve this problem 1 Unplug the TP 100 2 Turn on the AM 500 3 Press and hold the stop tracking button of AM 500 to make the indicator flashing Keep AM 500 facing TP 100 front side 4 Plug the TP 100 and keep pressing the button for about 5 seconds 5 Release the button and TP 100 will restart The power indicator would show orange which means the system turned to DHCP successfully Network Setting DHCP IP Address 192 168 1 100 Subnet Mask Default Gateway 6 Do the above steps again and you would change TP 10
15. ny barrier in a range of 3 5 meter Keep reflective object e g mirrors and glass out of the moving range of the target object Keep other light sources in a position that angle between the center line of their light beam and the center line of your TP 100 faced to is greater than 45 degrees see Figure below 45 22 100 User Manual S NEN The optimum installation distance Standard classroom Classroom for higher education is usually of area 135 180 m2 General classroom is usually of area 60 90 m2 For classroom in a rectangle shape and the blackboard end has a width of 10 meter the optimum installation layout may look like the figure below 10m 10m lt lt Y We 1 s s iN 1 3 N 4 s i E N 4 7n 4m i m i z m 7 ge m 1 s 1 1 1 1 1 1 ri 9m 4 9m 1 7 1 1 1 1 1 1 Assume the classroom is of width at 10m TP 100 is away from the blackboard at 4 7m You may employ the projector ceiling mount in the system installation You may employ a projector ceiling mount in the system installation to adapt to different classroom height There are many hanger options See figure below for some examples 23 TP 100 User Manual zz Installation conditions 4 5m 2 5m WE 4m poc 2 35m 16 B 1 2m The shortest you
16. or function key Stop tracking and sound receiving Effective range of A circle of 12 meter radius from microphone to sound receiving antenna microphone Locator power supply AAA dry cell X 2 Please use the Duracell alkaline battery Power consumption 6 to 8 hours Duracell alkaline battery estimates Based on actual results in recommended indoor operation environment The wireless microphone must work together with KS 700 media station x Without wall human body or any large size barrier in between Arc 2 Getting to know your product B Front light indicators B Front B Rear nmo Ethernet DC12V 12 Em x TP 100 User Manual 5 Power light indicator E TP 100 network light indicator Cx Camera network light indicator Steady green When powered ON Flashing green When any object is identified A Fast removing board for camera mounting B Standard 1 4 20 UNC screw hole to fix to the fast removing board C M3 screw holes for fixing with included screws A TP 100 external network port B TP 100 external power socket C RS 485 connector D Power and network connector for TP 100 and Cloud console To connect to LAN or KS 700 device 100 User Manual
17. pacity for the required current DO NOT insert the adaptor in the power socket before wiring to avoid personal injury 9 Please remove the power plug if you are not to use your product for long time to maintain electric safety Remove the plug by holding the plug s plastic part with dry hands 10 Please wire your product according to the installation guide and instructions printed on your product for the optimal effect 100 User Manual Hardware specifications TP 100 Auto Tracking System Panning 355 degree Rotation oe Tilting 60 degree 25 35 degree Tracking range A circle of 2 12 meter radius from locator to TP 100 control web page 100 setup page along with KS 700 online directing Manual operation Joystick amp console control RS 485 interface Enable disable tilting control for auto tracking Tracking sensitivity and environment optimization Offset position definition 15 preset points and 3 patrolling path Setup function One login user account and password management Device name definition and software update Enable auto full view function Network setting RS 485 protocol setting Power supply DC12V 2A TP 100 CI 200 Working temperature Celsius 0 50 degree RJ 45 port 2 Interface Power socket 2 RS 485 connector 1 Authorized external camera devices 200 18X digital network camera 500 wireless microphone Locat
18. r TP 100 can be tracked Assumptions 2m x cos35 1 64m 1 Height of the target 1 7m 2 AM 500 is worn at 1 2m above the ground 3 The ceiling is 2 5m high 7 5m 2 5m m E 2 35m i pices 16 1 15m 1 2m The shortest distance your TP 100 can be tracked 1 6m Assumptions 2m x cos35 1 64m 1 Height of the target 1 7m 2 AM 500 is worn at 1 2m above the ground 3 The ceiling is 2 5m high These two figures are for illustration only The proportion may be incorrect 24 AUC GC ERE AREC Inc All Rights Reserved 2013 www arec com All information contained in this document is Proprietary Made in Taiwan 9 t Version 2013 9 2 I
19. sk 255 255 255 0 Protocol 60 Defeun Gat 19216811 Password eeeee Bard Rate gt Discard Modification Aon Log in 1 Your TP 100 connected to a desktop or notebook computer 1 Click to open Network and Sharing Center Currently connected to Internet access Open Network and Sharing Center View your basic network information and set up connections See full map MESSOA VM Network 3 Internet This computer View your active networks Connect or disconnect Access type Internet Network 3 Home network HomeGroup Available to join Connections 2 Click the Properties button in Local Area Connection window and click the Internet Protocol Configuration TCP IPv4 option Connect using IPv4 Connectivity Internet AP Intel R PRO 1000 MT Network Connection Ps comet No tenet Media State Enabled This connection uses the following items Duration 00 04 52 0 Client for Microsoft Networks Speed 1 0 Gbps 005 Packet Scheduler inum 4 Link Layer Topology Discovery Mapper 1 0 Driver Activity 4 Link Layer Topology Discovery Responder Sent Received veel Bytes 70 112 a Transmission Control Protocol Intemet Protocol The default across diverse interconnected networks Properties Disabie Diagnose 11 100 User Manual
20. tton inside your product that needs any operation from you For your safety DO NOT open the outer case of your product apply improper operations on it e g turn or swing it with great force as you may get an electric shock and or void the limited warranty Contact your local dealer should there be any problem with your product 3 For better tracking effect please do not track in limited spaces Install your product in open space without surrounding walls Avoid walls barriers like large size glasses and metal objects in the planned tracking space 4 The optimum installation distance 4 7 meters away from the target object at height 2 5 meters above ground 5 Your product is designed for use in indoor environments and without direct sunlight For room with window s please have curtain s installed 6 Please use your product in proper environment Please DO NOT install your product in the following environment e Unstable location or uneven surface Location near strong magnetic field e Damp or leaking environment Overheat or place near heater or wind pipes or location exposed to direct sunlight for long time e Dusty location e Vibrating location Close to any amplifier 7 In case smoke or odor is detected unplug the power adaptor and send to the service center for maintenance 8 Please insert the plug of the adaptor firmly in the power socket without exposing the pin to avoid electric shock Ensure the socket is of adequate ca
21. ween static IP amp DHCP The light turns green then turns off after power Upper side Red and green ON The light turns red when power is low The light flashes blue intermittently if without paired device The Int flashes blue fast when pairing with one device The light flashes blue slowly when paired with one device successfully 6 How to install your system Your TP 100 can be ceiling mounted or wall mounted or affixed on a stand See below for each installation method 1 Ceiling mounted installation 1 Remove the ceiling panels at the target 2 Open the positioning sticker and affix it to the installation location desired location at the target ceiling Drill holes with a drilling tool p 100 User Manual za 3 Align the screw holes in your TP 100 to the holes you made earlier lock it with the included screws and nuts 4 Replace the ceiling with TP 100 to its original location connect both the network and power cables and the installation is completed 2 Wall mounted or on a stand 1 The standard 1 4 20 UNC and three screw holes at bottom of TP 100 enable it to mount to a wall or on a stand q A 2 Fix the hanger or stand to a wall or floor then mount your TP 100 to the fast removal board or the screw holes in the hanger 100 User Manual Ee NN Note 1 Some hangers may feature a screw locking place with limited size The
22. wer wire to connect your TP 100 5 Connect the network and power cables by and the network camera If your network camera referring to the printed instructions at the back comes with a power terminal block then lock it of your TP 100 and the installation is to the power wire first Please make sure you completed have the anode and electrode aligned correctly The white end is the anode and the black is the electrode 10 100 User Manual Arc 9 The TP 100 management web page You can connect your TP 100 to a PC or notebook with standard network cable and enter the TP 100 management site via your Internet browser or connect your TP 100 to a KS 700 and enter the setup page via the KS 700 management web page See below for details Laco Auto Tracking System Maal Control Device Info r Installed Direction E Logo UprightiCamera above Tracker Upside Down Tracker above Camera 8 1 01 00 00 Firmware V WOO 1S2 3 3 V Enable Pan Horisontal Enable Tit Vortica Firmware me en Offset Position Define pan 0 Left 0 Right Offset Position Definectilt 0 Down 20 20 Up New User Nome Sermtivity New Password Confirm Password Following Speed Madam System Administration Network Setting DHCP User Name admin 86 485 Settings _ Subnet Ma
23. xm e s 13 10 THE ADMINISTRATOR WEB 17 11 HOW SETUP AUTO FULL VIEW 22 12 HOW DO WHEN YOU FORGET THE IP 55 24 jog uuu 25 100 User Manual 1 Product information Safety precautions Battery safety information lll Keep the battery at a dry and cool environment lll DO NOT dispose of your battery with household waste Send used batteries a specific re cycling location ll Remove your battery out of your device if you are not to use it for long time Do the same with empty batteries as the remote controller may be damaged by leakage of current and battery liquid lll DO NOT mix old and new batteries together for use Please use the alkaline Duracell battery recommended by the supplier DO NOT mix batteries of different brands together for use DO NOT expose your battery to flames as this may lead to explosion or power leakage DO NOT short circuit the anode and electrode of your battery Precautions before using your product for the first time 1 Please open the package of your product with care Please keep the packaging material as you may need them for transport storage or return for service in future 2 There is no switch or bu
Download Pdf Manuals
Related Search
TP 100 tp 100-480 tp 1005m top 100 movies tp 100 turboprop engine price
Related Contents
Kraun Digital Photo Frame 7" 対応ソフ ト一覧 Moving-Head Sony VAIO VPCCW18FX Instruction manual gapCONTROL setup software - Micro Origin Storage KB-DWJGR notebook spare part Worldwide Homefurnishings 501-890BK Instructions / Assembly Import/Export .BIN .BCN file ダウンロード D-Link AirPlus Xtreme G Copyright © All rights reserved.