Home
M Series Manual
Contents
1. Language Hide Play window LED Screen Monitor Hardware Setup User Setup M Pic 5 1 M10 Operation Manual page 9 2 Once Software Setup is active Pic 5 2 type linsn on keyboard A pop up menu will come up requiring a password which is 168 Pic 5 3 software Setup x Play Window Auto Hetworking Other C Lock to LED Scree C_Multi LED Combination synchronism Combination synchronism setina Floating LED Numb i Update LED Numb Screenl Stark 4 z280 Widthtwh 256 Start Y 9 HeighkiH 256 W Enable Change By Mouse Standard P Alwayon top Frames 30 Save Setup Close HEEN Pic 5 2 software Setup Eg Play Window Auto Hetworking Other Lock to LED Scree Multi LED Combination synchronism Combination synchronism Setting f Floating LED Numb i Update LED Numb Screenl Input Password Please input Password stark x stark Y le Enak __Alwayon top Frames 30 Save Setup Close HEEN Pic 5 3 M10 Operation Manual page 10 5 4 Loading a set up CON file if available If there is a CON file available for your current configuration 1 Click Display connection choose Display Qty and enter the number of displays then click Load from file Pic 5 4 Setup hardware parameters Sender Receiver Display c
2. nn Ider or Card Save Card for maintair Load From file Save to File Send to receiver 2 Click Send to Receiver to update the setting and then click Save to Receiver Pic 5 9 Setup hardware parameters Sender Receiver Display connection Set mode Simple Normal C Complex V Use Auto link Remark The dialog of settings for single or multi regulation led screen Display QTY 1 Update display QTY display 1 Type Single color display Horizontal card 9 vertical card 5 Quick Sort Gama 2 8 J7 virtual display Red brightness 255 Green brightness 255 Blue brightness 255 Oorder No 21 Owidth 64 Main cable Card brightness Red fo Green fo Blue ard Gave Gard For maintain Load From file Identify Fo Pic 5 9 M10 Operation Manual page 14 3 Click Sender tab Display mode must be 1024 x 768 Pic 5 10 Exit and Save Setup hardware parameters Va Receiver Display connection Display mode 8G only Port of hot backup Y Card 1U Card 1D Hardware port lW Use 8G F Use 10 bit colors Mai d Auto Sender Num 1 ad V Use plug and play For DVI Y Start Enable dot correct for soft Iv Auto Enable dot correct for hardware V Use monitor for card box Set Width F Use monitor for dot Color iel 3 starty D l Single Color only V Enable Color Adjust Width 1 Height 1 Enable ExCard Bright T SE Manual G
3. M Series Full Color Outdoor Modular Display Operation manual Content SNE DE 3 INSTALLATION REQUIREMENTS ane eeneneneneeen eeens 3 2 1 Installation requirements for the display oane 3 2 2 System requirements for the control software 3 SYSTEM OVERVIEW pairon natens unten tteneiedn adden 4 3 1 The fundamental elements of the display system 4 3 2 Structure of the LED display system an nannn enn ennnen vennen 4 3 3 Control SySTeM nntb 5 CabineEeonheelOfl mmniet endet enb Ae 8 LED Display control system set Up aanneem en senen venen e ennen 9 DT OOMWare INSTA AHO rr veerserdnsand negenen wesc neem epmiersanedattoneencunasetaaed io 9 52 SSONW ALE SETUD nente heee aes 9 50 SEUD ine RECEIVE wssn ne eten deans eet eee 9 5 4 Grid connection set up with available CON file nennen 11 5 5 Grid connection set up with no available CON file nennen 13 5 6 Grid connection completed aans e rennen senen eeneneennen senen eenen 13 Common ENOS Aarsen A 16 M10 Operation Manual page 2 1 SAFETY Make sure you understand and follow all the safety guidelines safety instructions warnings and cautions mentioned in this manual Be aware of suspended loads Wear a hard hat to reduce the risk of personal injury Be careful while working with heavy loads Mind your fingers while working with heavy loads 2 INSTALLATION REQUIREMENTS 2 1 Installation requirements for the display Weig
4. Network cablelNetwork cable Network cable Network cable Network cable Dorder No 4 Oorder No 3fDorder No 3 Oorder No 2 QOorder No 2 Oorder No 1 Oorder No 1 Oorder No 7 DOorder No 4 Owidth 64 Owidth 6 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Oheight 64 Oheight 6 4 Oheight 64 Dheight 64 Oheight 64 Oheight 6 Oheight 64 Oheight 64 Oheight 64 Network cable Network cable Network cablelNetwork cablelNetwork cablelNetwork cablelfetwork cable Network cable Network cable Dorder No 4 Oorder No SijDorder No 3 Oorder No ZijDorder No 2 Oorder No 1ijDorder No 1 Oorder No 8 Oorder No 3 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Network cable Network cableffletwork cablelNetwork cablelNetwork cablelfletwork cable Network cable Network cable Network cable Oorder No 4 Oorder No 3Oorder No 3 Oorder No 2 Oorder No 2 Oorder No 1 Oorder No 1 Oorder No 9 Oorder No 2 Owidth 64 Owidth 6 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 6 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Geer Network cableffletwork cableffletwork cable Network cablelNetwork cablelNetwork cablelfletwork cableffetwork caf Dorder No Oorder No 4Oorder No 3 Dorder No SjDorder No 2 Oorde
5. e signal cable refer to the diagram in the user manual Note the diagram is viewed when people face the back of the display Check the PC and sending card connection Please refer to the document Connection between PC and System Power on the PC and LED display Check each receiving card in the cabinet If the red lamp on the receiving card is lit it means the receiving card has power to run if the red lamp does not light please check the power supply to the cabinet If the green lamp is lit it means the receiving card has transferred the signal if the green lamp does not light go to the next step to check the graphic card setting Click the button of LED Studio on PC Check the connection of the serial port cable which is between the PC s serial port and the sending card if the software shows that the PC cannot find the LED display Check the lamp on the sending card If the red lamp of the sending card is lit it means the sending card has power to run if the red lamp does not light please check the PCI socket on the PC s motherboard e Ifthe green lamp on the sending card is lit it means the sending card has transferred the signal out to the receiving card if the green lamp of the sending card does not light please check the graphic card setting Refer to document How to set the graphic card on PC After processing all the above steps your display will start to work e To
6. ht Do not underestimate the weight of a complete display Be sure that the floor or truss installation on which the perimeter display has to be installed is capable of handing 5 times the complete load of the display Level surface The surface on which the display has to be installed must be level Never install the display on an inclined surface 2 2 System requirements for the control software System requirements Minimum specifications Hardware PC Pentium IIl or equivalent 1 GHz 512 Mb RAM Hard disk 500Mb XGA 1024 x 768 Software Windows 2000 Windows XP Home or Professional edition M10 Operation Manual page 3 Recommended specifications Hardware PC Pentium VI or equivalent 2 4 GHz 1 GB RAM Hard disk 80GB SXGA 1280 x 1024 with 512 Mb video memory Software Windows XP Professional edition WIN7 3 SYSTEM OVERVIEW 3 1 The fundamental elements of the display system LED module Drive board Inner power supply Structure Control system 3 2 Structure of the LED display system The sending card should LED DISPLAY be installed in the PC using a PCI socket or in a sender box UTP CAT5e ep AC9 260V Power cable M10 Operation Manual page 4 3 3 Control System Scaler Sending Box Control Computer ILL LLL 3 3 1 The sending box The Sending Box is located in the rack with the control computer Additional function interface is connected to the Serial port Two s
7. ignal output ports U port and D port will connect the curtain wall via cat5 cable SENDER Jada g raam EEEF e 5 Ch e eV Power 3 L Bo Gee AC90 260V IN ove Upati OC oor cmai USA Sending Box UTP other side connects to the cabinet Connect the DVI output of the independent graphic card to the sender by this USB wire DVI cable Sending Box cable connection method Three cables normally we only use one RJ45 for output will be linked to M10 Operation Manual page 5 the sending card while the display is working DVI cable USB cable and Cat5E cable The DVI cable will be plugged inthe DVI port for data input to the sending box the Cat5E cable will output the signal data to the receiving card located in the M10 Modular and proper USB port connection is required when the curtain wall set up is needed 3 3 2 Diagram of the control system RS232 USB DVI Signal Output Port to Scaler DVI Cable Signal Output to the PC monitor Te Graphic Card U RJ45 Date output use UTP cable to Receiving card D RJ45 Date output use UTP cable to connect to Receiving card o gt si Audio output _ _ _ _ _ USB Date output connect to computer with USB wire and transfer date between sending card and computer to let LED display control by software DVI signal input to connect to graphic card al Baas 1 ed j ts Sending Box UTP Cat5 RJ45 signa
8. l input from sending card gt RJ45 signal output to next receiving card Receiving Card connect in Module Next Receiving Card Module M10 Operation Manual page 6 3 3 3 Graphic card setting Once all the cables are connected back to your computer to do the graphic card setting Connect the VGA to the graphic card of the computer Power up the control computer After the computer is powered up connect the DVI to the graphics card and re boot When the Green indicating LED of the sending card blinks it means the sender is working 3 3 4 Sending Box SENDER aas j HH E AC90 260WIN Data Output DVI Interface Data Output D Port External Power U Port Input Communication USB port The Sending Box is to transmit data to the receiving card on the display It has four kinds of interface DVI interface additional function interface data output interface and external power interface DVI interface DVI interface is a data input port which is designed for Graphic card signal transmission Communication USB port it is to control grey level LED display power switch to lock display and to show the area set up To operate with LED Display this interface is to connect with USB for receiving card set up Data output interface There are two output interfaces on each sending card It is to connect to the Receiving Card via pin to pin CAT5 UTP 4 unshielded twisted pair The sequence of the twisted pair is white ora
9. nge orange white green blue white blue green white brown and brown Both sides are the same sequence M10 Operation Manual page 7 4 Cabinet connection 4 1 power installation guide Back of display NOTE One 15 amp circuit will power one row of five 5 modules 4 2 signal installation guide coe EEE Lecce EEE ALLELE BED EEL ELL Signal input Back of display M10 Operation Manual page 8 5 LED Display control system set up 5 1 Software installation Insert disc LEDStudio10 in CD ROM Click set up file to install LEDStudio10 to computer hard disk The serial number and password are asked for during installation The Serial number is 888888 and password is 168 Please refer to LINSN user s manual for software operation detail 5 2 Software set up After software installation is complete you will need to set up the software by creating or loading the Display Connection Setup CON file If your display shows the wrong sequence load or create the CON file following the steps below 5 3 Set up the Receiver 1 Click Option on the menu bar then click Software Setup as shown In Pic 5 1 ieee Test Help Sereen Combination synchronism Brightness Contrast Color B Screen Area I Virtual Real Led screen lY Flay Background Lock LED Sereen Properties Turn off LED sereen power Schedule Table schedule Hide Setup
10. onnection Set mode Simple Normal C Complex FT Use Auto int Remark The dialog of settings for single or multi regulation led screen Display QTY 2 display 1 display 2 Type single color display Horizontal card fo vertical card B Virtual display Gama 2 400 C define Edi Red brightness 255 Green brightness 255 Blue brightness 255 Main cable caD Extension cable Order No l width A Height spuru Card brightness Red f 5 Green 55 pja ad Data Screen area color correction n Load from file Save to file Send to receiver Save tc eT Pic 5 4 2 Choose a configured file CON in the pop up window Pic 5 5 Setup hardware parameters Sender Receiver Display connection Set mode Simple Normal Complex Use Auto link Remark The dialog of settings For single or multi regulation led screen isnla display 10T R 9x5 layout CON Axe Calgary revised CON My Recent calgary CON Documents Edmonton CON Main cab My Network File name 3x5 layout CON hd Places Card brig Files of type Connect Files CON v lentify For Gar Save Card For maintair Load From File Save to File Send to receiver Pic 5 5 M10 Operation Manual page 11 3 After loading the file click Send to receiver to update the setting and then click Save on receiver to save all settings Pic 5 6 Then the operation is over Setup hardware parameters Sende
11. r Receiver Display connection Set mode Simple Normal C Complex MV Use Auto link Remark The dialog of settings For single or multi regulation led screen Display QTY 1 Update display QTY display 1 Type 5ingle color display Horizontal card 9 vertical card 5 Quick Sort splay Red brightness 255 Green brightness 255 Blue brightness 255 Main cable Card brightness Red fo Green Blue Identify for Card Save Card for maintair Load From File Pic 5 6 M10 Operation Manual page 12 5 5 Connection set up if there is no available CON file for your current configuration To set up the screen configuration if there is no CON file available for your current configuration you will choose the number of displays used 1 Choose the Display 1 tab 2 Enter the number of horizontal cards modules in the space provided 3 Enter the number of vertical cards modules in the space provided 4 Click on the bottom right box Pic 5 7 Setup hardware parameters Sender Receiver Display connection Set mode Simple Normal C Complex V Use Auto link Remark The dialog of settings for single or multi regulation led screen Display QTY 1 Update display QTY display 1 Type Single color display Horizontal card E vertical card 5 Quick Sort Gamal28 T Red brightness 255 Green brightness 255 Blue brightness 255 Network cable Network cable Network cablelNetwork cablel
12. r No 2fDorder No 1 Dorder I Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth 64 Owidth dki Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight 64 Oheight d Main cable 1 No sender U ca 7 Extension cable 1 Order No 1 width 64 Height amp Abnormity Card brightness Red 255 Green 295 Blue 255 Load Data Screen area color correction Save Card For maintain Load From file Save to file Send to receiver Pic 5 7 5 Choose Main cable output location that was used to send the signal 6 Confirm or change order number pixel width height 7 Click on the second block in the chain and continue following the wiring pattern of the sign M10 Operation Manual page 13 5 6 Grid connection completed 1 After building the configuration file click Save to File Pic 5 8 Name and save the file Setup hardware parameters Sender Receiver Display connection Set mode Simple Normal C Complex MV Use Auto link Remark The dialog of settings For single or multi regulation led screen Display QTY 1 Update display QTY display 1 Saye As Save in O SetData gt et EB 9x5 layout CON Axe Calgary revised CON My Recent calgary CON Documents Edmonton CON My Network File name Places Save as type Connect Files CON ba Cancel Main cable 7 Card brightness Red fo Green fo Blue E aias
13. rey 16 32 C 64 E Screen power syn mode Virtual by interleaved C f Auto on off r Mode Mone C off f gt Direction os A Hardware other Offset Hardware 00 1 32 dot change at 8 row Step Momdel Unkown M 32 dot change at 16 row Check Hardware Default Save on sender Pic 5 10 4 In Software Setup enter the screen size of the current configuration The width and height will be 64 pixels times the number of modules used in this configuration ie 64 x 9 576 w If you used 9 modules to build the width of the screen then enter 576 for the width 5 For the Start X and Start Y axis enter 0 Save Setup Pic 5 11 Software Setup x Play Window Auto Networking Other C Lock to LED Screen 3 L combination synchronism Setting Floating LED Numb 1 Update LED Numb Screenl Start xi 0 Wiidkhiy 640 Start Y 0 HeightiH 192 Enable Change By Mouse Standard Always on top Frames 30 Accelerator Save Setup Close Pic 5 11 M10 Operation Manual page 15 6 Common Errors 1 Whole display not working When customer received the display and followed the user s manual to install the display but the display still does not work please complete the following process to check step by step Shut down the power of the display and check the connection of the power cable refer to the diagram in the user manual Check th
14. upload the RCG and CON files to the software please refer to Software Setting Instruction in the user s manual e In the last step refer to the LINSN S LED Studio User Manual and set what is supposed to show in the displays M10 Operation Manual page 16 2 o0 oo amp One or several cabinets do not work or do not work properly Check if the power supply is working properly in both input and output Input 110V 220V Output 5V If the power supply is working within 220V input and without 5V output replacing with a new power supply is recommended If the power supply has no 110V 220V input check the connection of each cable Check the working condition of the receiving card Check the receiving card connection of each cable both of power cable and flat cable or replace with a spare receiving card Check the connection of power cable and flat cable Replace power cable or flat cable Replace module with spare module One or several modules do not work or do not work properly Check the connection of power cable and flat cable Replace power cable or flat cable Replace module with spare module Part of one or several modules do not work properly Check the connection of flat cable on the identified module Check the working condition of PCP Replace identified module with spare module M10 Operation Manual page 17
Download Pdf Manuals
Related Search
Related Contents
Shure DFR22 Software User Guide (French) Declaración de Conformidad Instrucciones de Operación 取扱説明書(1.8 MB) Scheda Tecnica SV-BUP - allarmesatellitare.eu EAM: Inside the technology fonctionnement - Lincoln Electric Tarnac presse bourgeoise du 11 novembre 2008 - Cras 加減速パターンとバックラッシュ対策 Copyright © All rights reserved.
Failed to retrieve file