Smart Valve Positioner 700 Series

image

Contents

1. PHYSICAL SPECIFICATIONS Enclosure rating JISC0920 watertight IP66 Finish Baked acrylic Color Silver Material Cast aluminum Weight Without Pressure regulator with filter 4 2 kg With Pressure regulator with filter 4 9 kg INSTALLATION Air connections Rc1 4 or 1 4NPT internal thread Electrical connections G1 2 1 2NPT or M20 x 1 5 Conditions of supply air JIS C1805 1 2001 Particles Maximum diameter 3 um Oil mist Less than 1 ppm at mass Humidity of the air supply The dew point should be at least 10 C lower than the temperature of this device Azbil Corporation No SS2 AVP703 0100 FIELDBUS SPECIFICATIONS Function Blocks Block Number Period of Note name execution ms AO 1 30 For Set Point DI 2 30 For limit switches AR 1 30 Arithmetic block perform an arithmetical operation to the process measurement value PID 2 45 PID function block execute a control algorithm to minimize the error as the differ ence between a measured process variable and desired set point It also has func tions of cascade control feed forward control and alarm detection OS 1 30 Output splitter block perform the sprit control operation IS 1 30 Input selector block perform the control of select the process value VCR Structure The AVP has 32 VCRs Virtual Communication Relationships of which the first one is dedicated to the SMIB NMIB defined by the Foundation Fieldbus spe
2. V TDP Time Distribution Period 5000 5 to 55000ms V MICD Maximum Inactivity to Claim LAS Delay 2000 1 to 4095 1 V LDDP LAS Database Distribution Period 3000 100 to 55000ms No SS2 AVP703 0100 Azbil Corporation Note ALAS requires parameters other than those listed here to operate Please refer to the user s manual that comes with your LAS device The T3 needs to be set between 15 seconds and 60 seconds The unit is octet time 256 Us Octet time is the time required to handle 8 bits of data on the Fieldbus Network 2 The unit is slot time Supply voltage 9 to 32 V Maximum Current 20 mA Registration Interoperability test ITK 6 1 approved Typical installation Figure 1 shows the wiring for the model AVP703 Fieldbus Another fieldbus device Figure 1 Wiring for model AVP703 Azbil Corporation No SS2 AVP703 0100 MODEL SELECTION 1 Structure Water proof X ATEX Flameproof Electrical connection G1 2 is not available C IECEx Flameproof Electrical connection G1 2 is not available D G1 2 Ret 4 Mm Ret 8 G Electrical Air piping Mounting thread Pressure gauge connection connection thread 2 Connection 1 2NPT v4NPT m Reis N inet maner smesunc Rore u moss maner we Roe Im Ben Standard Baked acryic Ooo Ts Goresion proof Bakss veins odel KZ03 pressure regulator with filter Mounted on P
3. No SS2 AVP703 0100 Rev 0 Smart Valve Positioner 700 Series with FOUNDATION fieldbus Model AVP703 OVERVIEW The model AVP703 is a FOUNDATION fieldbus equipped smart valve positioner The model AVP703 controls and manages the valve through Fieldbus Various diagnostic functions and the automatic configuration function of the 700 series as well as PID function blocks bring out real fieldbus advantages FEATURES Easy to use e Auto setup The auto setup function is a fully automatic configuration program that specifies the actuator and adjusts zero and span of the valve The program can be run with the simple operation of an external switch so that the adjustments of the valve can be quickly and safely performed in hazardous areas Valve diagnostics Following parameters can be monitored by Control Valve Maintenance Support System Valstaff Stick Slip Total Stroke Travel Histogram e Cycle Count Shut Off Count e Max Travel Speed e Valve signature Full stroke test High reliability e Positive seating The positive seating function completely shut off the valve when the input signal is lower than that set by user This allows full play to the shut off capability of the valves e Self diagnostics The self diagnostic function provides the ability to check the status of the positioner and to alert the failure Single model for multiple specifications The model AV
4. P703 settings can be changed without any replacement of changing of parts A single model Specifications are subject to change without notice can be modified to suit any application without any parts change e Flow characteristic Linear EQ Quick opening or user customized characteristics Actuator type Double or single acting actuator Fieldbus Functions e Transducer Block Positioner Transducer Block FF 906 compliant e Link master function This device supports Link Active Schedule function for control of fieldbus communication e Alarm function Alarm functions specified by FOUNDATION fieldbus specifications are supported such as various high or low alarms block alarm notices etc Alarms are output in compliance with NAMUR NE107 China RoHS This device is used in the Oil amp Gas Petrochemical Chemical Pulp amp Paper Food amp Beverage Machinery Steel Metal amp Mining and Automobile industries and therefore does not fall under the China RoHS Legislation If this device is used in semiconductor manufacturing equipment labeling on the device and documents for the China RoHS may be required If such documents are required consult an azbil corp representative Specifications No SS2 AVP703 0100 Azbil Corporation FUNCTIONAL SPECIFICATIONS Applicable actuator e Single and double acting actuator Linear and rotary motion actuator Approvals ATEX Flameproof and Dust appro
5. cifications The rest of the VCRs are fully configurable VCR No Configuration 1 QUB Server for NMIB SNIB 2 32 Fully configurable Network Parameters The following table shows the key parameter values that affect interoperability of the Fieldbus devices The LAS needs to be configured to satisfy these parameters If other devices on the same Fieldbus network require a greater number for them the greater number must be used This will degrade network performance though Symbol Parameter Factory Setting Range of Value V ST Slot Time 1 5 5 to 100 V MID Minimum Inter PDU Delay 1 10 10 to V MRD 1 xV ST smaller than 120 inclusive V MRD Maximum Response Delay 2 4 V MRD xV ST shall be greater than 20 and V MRD shall be smaller than 11 inclusive Tl SM Step Timer 48000 15 seconds T2 SM Set Address Sequence Timer 2880000 90 T2 gt T3 seconds T3 SM Set Address Wait Timer 1440000 45 T2 gt T3 seconds V FUN First Unpolled Node 0x25 0x14 to OxF7 V NUN Number of consecutive Unpolled Node 0xBA 0x00 to oxE4 V MSO Maximum Scheduling Overhead 1 0x00 0x00 to 0x 3F V DMDT Default Minimum Token Delegation time 0x56 0x20 to 0x7FFF V DTHT Default Token Holding Time 1 0x0400 0x0114 to OxFDE8 65 000 V TTRT Target Token Rotation Time 1 4096 1 to 60000ms V LTHT Link Maintenance Token Holding Time 0x0124 0x0124 to OxFDE8 65 000
6. emark of Fieldbus Foundation Please read the Terms and Conditions from the following URL before ordering or use http www azbil com products bi order html Specifications are subject to change without notice Azbil Corporation Advanced Automation Company 1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan URL http www azbil com 10 azbil 1st edition Feb 2014 No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation
7. ositioner odel KZ03 pressure regulator with filter with bracket for separated mount xtention lever In case of no mounting bracket eal tape prohibited ounting bracket material SUS316 In case of with mounting bracket Mounting bracket PSA1 2 Mounting bracket PSA3 4 Mounting bracket PSA6 VA4 to 6 Mounting bracket PSA7 Mounting bracket HA1 Mounting bracket HA2 HL2 Mounting bracket HA3 HL3 Mounting bracket HA4 HL4 Mounting bracket DAP560 1000 1000X ounting bracket DAP1500 1500X z Individual specifications PD_TAG max 32 character e NODE_ADRESS 0x e Input Characterization Linear Standard Equal persentage Quick opening User defined e Psitioner action Direct Single acting actuator Reverse Single acting actuator Double acting actuator Supply pressure classification 150 lt PS lt 300 kPa Standard 140 lt Ps lt 150 kPa 300 lt Ps lt 400 kPa 400 lt Ps lt 450 kPa 450 lt Ps lt 700 kPa e Unit of pressure gauge kPa Standard MPa bar psi kgf cm e Valve closed position DOWN Standard UP e Actuator type Linear Standard Rotary 90 Rotary 60 Rotary sub90 Rotary sub 60 DIMENSIONS Shows the typical dimensions of AVP703 Unit mm Output 1 air connection 142 4 Figure 2 Dimensions of AVP703 Note HART is registered trademark of HART Foundation FOUNDATION is a trad
8. val II 2 G Ex d IIC T6 Gb at 30 Ct lt Typ lt 75 C II 2 D Ex tb INC T 85 C Dd 30 C lt Timp lt 75 C IEC IP66 IECEx Flameproof and Dust approval Ex d IIC T6 Gb 30 C lt Typ lt 75 C IP66 Ex tb IIIC T85 C Db 30 C lt Tamb lt 75 C IP66 Output characteristics Linear Equal percentage Quick opening e Custom configurable 21 segments Stem travel range Feedback Lever Angle 4 to Bypass operation Auto Manual external Switch For single acting type only Air supply pressure 140 to 700 kPa 1 4 to 7 0 kgf cm Air consumption at the stable output 50 3 2 min N maximum at 140 kPa 1 4 kgf cm 4 0 min N maximum at 280 kPa 2 8 kgf cm 4 8 min N maximum at 500 kPa 5 0 kgf cm 8 min N maximum at 400kPa 4 0kgf cm for double acting type Maximum air deliver flowrate 110 min N at 140 kPa 1 4 kgf cm Lightning protection Peak value of voltage surge 12 kV Peak value of current surge 1000 A Vibration tolerance 2 G 5 to 400 Hz with standard mounting kit on Azbil Corporation HA actuator Ambient temperature limits 20 Waterproof 40 C to 80 C LCD 0 to 50 C ATEX Flameproof 30 C to 75 C IECE Flameproof 30 C to 75 C CE conformity Electromagnetic compatibility EN61326 1 2013 CE marking Ambient humidity limits 5 to 100 RH PERFORMANCE SPECIFICATIONS Accuracy 1 ES 2 5 with custom output characteristics

Download Pdf Manuals

image

Related Search

Related Contents

H60MR_US Press PDF 2005.06.21  Earth Juice 100050717 Use and Care Manual    Trust 370W PSU PW-5110 (4 Pack)  Manuel opérateur TG - Documentation CN  Whirlpool ER2MHKXPL02 User's Manual  Keston C25 Installation Manual  WBW-91280 Washing Machine Instruction Manual  Geospatial modeling system providing inpainting and error  USER MANUAL - Pa  