Home
        Business/ Home GSM Alarm System
         Contents
1.   to inform the user  When the external power  recovered  the system will send SMS    Power changer on       Switch  turn left to start the host  otherwise close     Antenna  GSM antenna  you should connect the antenna before    power supply   7  10 pin ports  GND  SIREN  RELAY1  RELAY2  SPEAKER  Oa Is       Ox I4    13  l2  l4    GND is educed end of ground    SIREN is to connect one end of siren  the other end connects to GND   RELAY 1  2  relay output  It is normally opened  and will keep closed for  three minutes when alarming  this function can be set off   When  alarming  it can link the power  video  etc    SPEAKER is to connect the speaker  the other end of speaker  connects to GND    h  l2  Is  l4  Is are wired inputs  short circuit or disconnect to GND will    trigger alarm     lll  Installation  a  Use a normal SIM card  delete all telephone numbers and    messages in the SIM card  insert SIM card   b  Then connect GSM antenna   c  Plug in DC power supply  and power on the unit  The LED will    change     LED status explanation             RECORD    SIGNAL                 STATUS       POWER       LED Status System working status    Hasn t turned on the switch  hasn t  Off connected the power  no power in  POWER  built in battery    power supply is normal    SIM card or GSM network is abnormal  SIGNAL  Green  flash  SIM card and GSM signal are normal    RECORD    Remote controlled by SMS commands    Red  flash quickly     Orange Check SIM card and search GSM   flash
2.  even melt some plastic parts    Do not place the system in excessively cold locations  Otherwise   condensation many occur and damage the circuit board of the   alarm system    It is recommended that you check and test the alarm system   periodically    Check the main unit every three months    1  Whether it can arm disarm normally    2  Whether it can dial the number for alarm normally    3  Whether it can receive wireless detectors    signal normally    4  Whether the back up battery can work normally    Check the wireless detectors once a month    1  Trigger wireless detectors to see if system can alarm normally    2  Check all detectors    batteries to see if it   s in low voltage    3  Check whether wireless detectors can send signal to the main  unit normally    Check the SIM card     1  Check the use of SIM card  such as network signal  balance     ect   2  Make sure the PIN code verification of the SIM card is closed     3  Please keep the password and SIM card number safe  in case  that other people remote control the system illegally     Since the alarm system is continuously in operation or standby  mode  the supply adaptor of the control panel shall be connected    to a safe and reliable socket     18     lt  Do not place the system near your bedroom or office table   because the siren will make high loudness sound in the case of  alarm  which may adversely affect your rest or work     lt  If the alarm system will not be used for a long time  please  disconnect t
3.  number 13988821003   123456 1 8 13988821004  Call the 4th phone number 13988821004   123456 1 9 13988821005  Call the 5th phone number 13988821005       3  Defense zones setting  can be set only by SMS    Users can set the status of the defense zones according to their  requirements    a  Wireless zones setting   zone serial number  50 65  total  16 zones  zone  00 15     SMS commands  password  zone serial number   zone status    Message content     Zone status  0  disarm  1  arm  2  24 hour arm  system default  arm     E g  123456 50 1 hall  means set wireless zone 1 arm    50 indicates  wireless zone1  the name of the zone  hall  can be set  according to your actual situation    b  Wired zones setting   zone serial number  66 70  total  5 zones  zone  16 20     SMS commands  password  zone serial number   Zone status    Message content  Trigger type    Zone status  0  disarm  1  arm  2  24 hour arm  system default  arm   Trigger type  1  open circuit trigger to alarm  0  short circuit trigger to  alarm  system default  0  shorted alarm    E g   123456 66 1 hall  means set wired zone 1 arm and open circuit  alarm   NOTE  The host has 16 solidified SMS of the wireless detectors    wireless zone 0 15   the first SMS corresponds the first zone of  wireless detectors  other detectors are the same  The host also has 5  solidified messages of the wired detectors   wired zone 1 5   the first  message corresponds the first zone of wired detectors  other detectors    are the same  
4.  slowly  network  SIM card and GSM signal are normal  in  disarm status  Out Arm   flash slowly   Home Arm   flash quickly   STATUS Orange   flash slowly   Out Arm with delay time  10   s later green on  Orange   flash quickly   Home Arm with delay time  10   s later green on    or phone                 lt  gt     2     Door sensors are used  for detecting the status  of open and close of  windows and doors  It    will detect it and send    Host   Try to install the main panel in the center of defense zone and pull  out the antenna to get longer wireless receiving distance   Installation position should be far away from huge metal objects  and wireless interference     Install the main panel in a hidden place     Door sensor       the signal to main  panel  less than 10mm    Tear apart the     lt  gt    lt  gt     3     double side adhesive tape on the magnet and the transmitter   Then adhere them to the appropriate position    Magnet should be near to the side of transmitter with indicator   The two should align with each other and the distance should not  exceed 10mm    Please plug out the antenna for better signal     If the low power indicator is on  please change the battery     Wireless PIR detector    PIR detectors are used to detect the movement within a certain range      lt  gt     Fix the adjustment bracket on the wall with the provided screws    and attach the detector to the bracket  It is recommended to  mount it at a height of 2 2 2m above the floor     lt  Eff
5. 0  C  40   C  Humidity  lt  90  rh    Wireless PIR Detector   Power Supply  DC9V  built in 9V battery    Static Current   lt 100uUA   Transmission Current   lt 20mA   Transmission Frequency  315 433MHZ 0 5MHZ    16    Transmission Distance  No obstacle 80m  Detective Speed  0 3 3m s   Detective Distance  5 12m   Detective Range  Horizontal 110   Vertical 60    Working Condition  Temperature  10    C  40   C  Humidity  lt  90  rh    Remote Controller   Power Supply  DC 12V  built in 12V battery    Static Current  0   Transmission Current  15mA   Transmission Frequency  315 433 0 5 MHz   Transmission Distance  No obstacle 80m   Working Condition  Temperature  10  C  40  C  Relative Humiditys90     VII  Care and Maintenance  The alarm system has excellent design and used advanced    technologies  It shall be used with care  The following suggestions are   required to maintain your obligations under the warranty terms  and for   prolonging the service life of the system     lt  Place the control panel and all parts and accessories out of  children   s reach     lt  Keep the alarm system dry  Rain  humidity and various fluids or  moisture all will corrupt the electronic circuit     lt  Do not use or place the alarm system in dirty locations  otherwise    the electronic elements will be damaged     17     lt  gt      lt  gt     Do no place the system in excessively hot locations  High   temperature will shorten the service life of electronic equipment    damage batteries  deform or
6. Business  Home GSM  Alarm System    All Fer Your Security    BUSINESS HOME    GSM ALARM SYSTEM       User Manual    Profile  For a better understanding of this product  please read this  user manual thoroughly before using it     Thank you for purchasing this alarm system  For proper use and your safety  please  read these instructions thoroughly and carefully before you put the system in use   Keep this manual carefully for your reference in the future     Precautions    Please read and follow the brief instructions below  otherwise physical danger or  system damage may be incurred  This manual contains more detailed information  about safety issues concerning the system in other parts hereof        Proper use Waterproofness       Qualified  maintenance service    Read this manual The alarm system is Only those qualified  carefully before you put not waterproof  maintenance professionals  the system in use  Please keep it dry  may repair the alarm system     Operate in accordance  with the instructions herein     Backup Original parts and  40  Addition of       batteries other equipment  Be sure to back up all Only original parts and Before adding other  important information batteries approved by equipment please read the  stored in the system  manufacturer may be used  user manual for detailed    otherwise the warranty term safety instructions Be sure  may be breached and danger not to connect incompatible  may occur  products to the system     WN Switch on safety Interfer
7. Users can send SMS and change its contents     4  Function settings    Taking original password 123456 as examples     The following functions can be set by SMS commands or phone     SMS Content Function Description       4 1  123456 4 1    Open intercom function  D O  123456 5 0    Relay disconnected  D 1  123456 5 0    Relay connected    When you do the above settings by phone call  press password 12345         if you hear a long    di     it means the operation is successful  if there   s    di     twice  it means the operation is wrong  you should re input  Press        to    clear if the input is wrong     The following functions can be set only by SMS commands     Function Command SMS Function Description  fang  e   en  Set the time   31  123456 31    18 00 auto arm   of timing Arm time   arm  disarm   disarm time    123456  Close auto arm disarm  31H function    32 0  123456  No siren sound when   default  on    32 1  123456  With siren sound when  ee lem  amg    Relay 33 0  123456  Link the relay for 3  linkage 33 0  minutes when alarming        default  link    33 1  123456  Don t link the relay  AE ee re eo  37 delay 123456  00 99 seconds  default     of delay arm    38 delay 123456  00 99 seconds  default     disarm alarm time    38   00 99     00  no delay when    alarming     Language 39 0  123456  English version  Chinese  39 1  123456  Chinese version  en lame O    Addition     set the system time       Under normal working status  send SMS  password 31      Th
8. ect of the PIR detection is best when the detection direction is  in 90  angle with the walking direction of the intruder  Choose the  most suitable installation place and angle according to actual  situation and taking the following installation diagram as reference    to ensure the window 10 30         detection effect  is best    lt   Please do not fix    it under direct       sunlight or other  strong lights and also keep it away from places with frequent  strong air stream      lt  Ifthe low power indicator is on  please change the battery     IV  System settings  1  Change the password of the system  can be set only by SMS     Format  original password 30 new password   new password is 0 6  digits    For example  change original password 123456 to 888000  send SMS   123456 30 888000      2  Set alarm phone numbers and SMS numbers  can be set only by  SMS     The following operations take original password 123456 as example     123456 1 0 13988821001  Send SMS to the 1st phone number  eee  sameeren sama  123456 11 13988821002  Send SMS to the 2nd phone number  Serie  samaseer ang  123456 1 2 1 3988821 003  Send SMS to the 3rd phone number  Sees  somes mensan  123456 1 3 13988821004  Send SMS to the 4th phone number    123456 1 4 1 3988821 005  Send SMS to the 5th phone number  13988821005 when alarming   123456 1 5 13988821001  Call the 1st phone number 13988821001   123456 16 13988821002  Call the 2nd phone number 13988821002   123456 1 7 13988821003  Call the 3rd phone
9. ence Switch off in    restricted areas    Do not switch the Device All wireless devices may be Follow any restrictions     on when wireless phone susceptible to interference  Switch the device off in  use is prohibited or when which could affect aircraft  near medical  it may cause interference performance  equipment  fuel  chemicals     or danger  or blasting areas     Catalog    Functions  gt     Identify the Host    Installation           Bo aan a Camis E    Door Sensor __             Wireless PIR detector  System Settings  Change Password  Alarm Number Setting  Defense Zone Setting    Function Settings    Audio Message Recording     sX_si        eee eee    Add or Delete Detectors                         2    0220222 e es    Add New Detectors    Delete Detectors    Operation Instruction    Remote Controller    Components List    Techniqucal Parameters                                  0   0000 e      Care and Maintenance   lt  e2ttiscditecesriipemiiatetrree tigen    CoN O O DTD THT MT w pp               _                e  N O  gt  oO N N       oO    10     Ti     12   13   14   15     Functions   GSM 900 1800 1900 bands  can be used all over the world    5 wired and 16 wireless defense zones  each can arm  disarm and  24 hour arm independently    SMS of each zone  5 wired zones  16 wireless zones  can be  edited independently    Users can record 10 seconds alarm audio message with the scene  location information    Arm  amp  alarm delay function  the delay time is adjustab
10. he system from the power supply     lt  Please do not disassemble  repair and alter the products without  permission  or it may cause accidents and faults     lt  Do not drop this product on the ground or on hard objects  as it  may lead to massive impact to cause faults and damages     lt  Without approval and consent of relevant authorities  please do  not set    110        119    or the alarm phone number of police station for    this main unit     Please read the suggestions above carefully and follow the instructions  herein  If any of the equipment does not work properly  please send it to  the dealer or authorized service point for repair  We will try our best to    solve the problem for you as soon as possible     19    FAQ    1    Cannot alarm by phone    Remote controlling  distance is too short and  the light indicator is not  on bright enough    Light indicator of door    sensor and PIR is always  on     Dial alarm number slowly    The main panel cannot  receive signals from the  accessory    Hasn t armed   Less than 30 seconds  after arming   Set wrong phone  number   The two parts of  door window sensor is  installed too far from  each other   Haven t activated PIR  Hasn t checked code    The battery of remote  controller is rusty  Low battery    Low power battery    The main panel has stored  other numbers    1  Low power battery in the  accessory   2  There is block between the  control panel and the  wireless accessory or the  distance between them is  too fa
11. le  00 99  seconds     Timely arm disarm  convenient for users and alarm center to  control the system    Can set 5 phone numbers  which used to receive alarm phone and  alarm SMS    Set Out Arm  Home Arm  Disarm or Panic alarm with remote  controllers    Can control the system by calling in or SMS  such as arm  disarm   listening in  output  and so on    Listen in function  can hear the sound of people move  dig and  other actions at the scene    Two way intercom function  can communicate with people at the  scene    SMS alert for power failure or recovery    Password operation to make sure the security of system    Siren port for shift between silence and sound     Optional built in battery  AC DC shift  automatically recharge     Identify the ports of the host           RESET ON OFF       ao RELAY1 RELAY2 INPUT      SIM card slot  at the back of the main panel there is a cover of the    SIM card  open the cover and insert SIM card  then close the cover     2  Record  press it for 2 seconds to enter recording status     3  Rset  press    RESET    on the back of the host and then plug in power     5   6     The signal light flashes once or the siren sounds a    di     means the  main panel has been reset  The system restores to factory settings     and all detectors are deleted   default password is 123456       Power slot  connect 12V 1 2A DC  inner core is positive  shell is    negative    When the external power is cut off  the system will send SMS     Power changer off  
12. ng SMS to the number and then make alarm  call  Answering the call  the user can hear the recorded message   press         to hear it again    When alarming  user can listen in by pressing 3 1    When alarming  user can talk to people at the alarm scene by  pressing 4 1      Note    For normal use  if there is built in battery  when external    power fails or recovers  the host will send messages to inform users     12    The message content  power change off on  year month day     hour minute second     Control the host with remote controller  The remote controller has 4 keys     Out Arm  Home Arm  Disarm  Emergency    Out Arm       Disarm    Home Arm  Emergency    1  OutArm     Press the    Out Arm       button on the remote controller  the STATUS    indicator on the main panel flashes in orange  10 seconds later  it will  turn green with slow flash  The system enters Out Arm mode  and all    the detectors will be in working status     2  Home Arm     Press the    Home Arm by     button  the STATUS indicator on the main    panel flashes in orange  10 seconds later  it will turn green with fast  flash   Detectors inside the house  in inner defense zone  will not work  only    the detectors outside the house  in outside defense zone  will work  so    13    that people inside can move freely  but others who break in from outside    will trigger the alarm     3  Disarm     Press    Disarm   button  the system will enter into disarmed status     the STATUS indicator on the main 
13. panel is green     4  Emergency     When there is an emergency  press the    Emergency A     button on the    remote controller  the system will alarm immediately no matter it is in    arm or disarm status     V  Components list    1  Basic kit   Main panel 1 pc    Remote controller 2 pcs   PIR sensor 1 pc    Door sensor 1 pc    Siren 1 pe    Power adapter 1 pc    Antenna 1 pc   User manual 1 pc     14    2  Additional sensors    Signal Repeater         Glass Sensor    Wireless Smoke  Detector    Fai    S     Wireless Outdoor  Siren with flash       FEES    Wireless keypad    6 lee    at  5      Si  Panic Button Remote Controller     gt      Wireless Pat    Gas Detector  Immune PIR Detector    Optional sensors detectors are packed separately  You can choose  according to your specific requirements     Typical house configuration    External Sirens       Doorfwindow       Garage    Smoke PIR Movement    Detector Detectors     Se J       15    VI  Technical Parameters    Main Panel  Power  9V 12V DC    GSM frequency  900 1800 1900MHz  Receiving code  ASK   Receiving frequency  315 433MHz  Wireless distance  no obstacle 100m  Wireless detectors  16   Wire detectors  3    Working temperature   10  C   40  C    Wireless Door  Window Detector   Power Supply  DC12V  built in 12V battery   Static Current   lt 20uA   Transmission Current   15mA   Transmission Frequency  315 433MHZ 0 5MHZ  Transmission Distance  No obstacle 80m   Alarm Distance  15mm   Working Condition  Temperature  1
14. r   3  The accessory has not  been coded to the panel    20    Arm the unit  Operate after 30  seconds  Set the number  again according  to the manual  Adjust the  installation place  of the door  sensor  Activate the PIR  Check code again    Clean the rust  Change battery    Change battery    Set it again according  to the operation  manual    1  Replace the battery   2  Pull out the antenna  of the accessory and  the main panel  and  adjust the position   3 Code it to the main  panel       
15. resents zone 4   How to trigger the detectors     Door sensor  separate the two parts  PIR detector  move across    the detector  remote controller  press any key on it      Note    door  window sensor is for external zone  PIR sensor is    for inner zone    Press Out Arm key  all detectors in external and internal zones will    be in arm status     Press Home Arm key  only the detectors in external zones will be in    arm status     11    2  Delete detectors   If wireless detector  eg  remote controller  is lost  you need to delete  the lost detector for your home security  Press    RESET    key then power  on  10 seconds later the STATUS LED changes from orange to red  and  then from red to orange again  At this time  the system restore to  original status  password is 123456  all the detectors are deleted     For normal use  the wireless detectors must be code to the host  according to adding detectors methods    If you want to delete wireless sensors in a certain zones  you can  send SMS  password defense zone serial number50 65      For example  123456 50     it means deleting the sensors in zone  50    VI  Operation instruction  When the host is powered on and disarmed  users can use remote    controller  Out Arm  Home Arm key  or send message  123456 1 1    to arm  Under arming status  the green light flashes  Triggering any  wired or wireless detectors  the host will make alarm    1  If there are phone numbers stored to receive SMS  the host will  send the correspondi
16. us the system time will be the same as the time of GSM base station     5  Audio message recording   Users can record geographical location  home address information  as alarm audio message  which will be played when alarming   Recording operation    Press the record key for 2 seconds until the light RECORD on  and  then speak to the microphone which embedded at the left part of the  host  10 seconds later the light RECORD will be off  the system exits    recording status automatically     10    V  Add or delete detectors    1     Add new detectors    The PIR  door sensor and the remote controller in the standard kit    have been coded to the main unit  If you want to add more wireless    sensors  please refer to the following instructions     a     Internal zone detectors  In normal working status  press    RESET     key for 2 seconds  the STATUS LED turns red  then trigger the new  detector  If the LED flashes one time  it means the operation is  confirmed  20 seconds later  the host will exit automatically and  turns to normal working status   External zone detectors  In normal working status  press     RESET    key for 2 seconds  the light turns red  then  press    RESET    key again  the light turns from red to orange  trigger  the sensors  If the LED flashes one time  it means the operation is  confirmed  20 seconds later  the host will exit automatically    If there are 3 detectors stored  they represent wireless zones  1 3  if you add a new detector  this detector rep
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
TECDIS IME EN wo Furuno rev 1_9  H2O Audio iN2 User's Manual  User Manual  LO + DESTACADO  Radio Shack 49-1010 User's Manual  User`s Guide    Miele G 6105 SCU CLST Futura Crystal Operating and Installation Instructions  Descargar en PDF - Trapo de limpieza  RiskyProject Administrator`s Guide    Copyright © All rights reserved. 
   Failed to retrieve file