[ user manual ] - Electro Optical Components, Inc.
Contents
1. Electro Optical Components Inc 5464 Skylane Boulevard Suite D Santa Rosa CA 95403 Toll Free 855 EOC 6300 www eoc inc com info eoc inc com user manual Fiber Coupler iD1 FC Dual mirror Fiber Coupler Suitable for iS5 FTIR spectrometer Iskander Usenov mp pm Type Fiber Probe Coupler for FTIR spectrometer iS5 from Thermo scientific Document Version Tatiana Sakharova Specification 2 Table of contents MOGU e BE 3 1 Safety Instructions sececpe scree seceton vagexctoaxaue wateexetavveoweyexesaxceouseenesarcecsasexesaneteusieeee 3 1 2 SCV eet er 4 1 3 Customer service and warran y cccccceececeeececeeeceseeeeesaeeeeseeeeesaaeeesaeeeeens 4 1 4 Operating conditions cccceccceececeeeeeceeeeeceeeeeceeeeeseueeeseeeesseseessaeeesaaeeesaaes 5 1 5 gt 8 2 e EE EEN 5 1 6 Handling fiber couplers And cables nnannnannnannnnnnennnannnnnnnnnnnnnnnnnsnnnnnennne 5 I Specifications eee 6 IN lee AVG AN e La EE 6 IS Sieden 7 1 2 1 Parabolic MIM OVS vecceccteccieccteceecetbeiceceticavecedecicecets eiccdacteacedi lt auseoteeiceerdicts 7 M GONE e Be EE 8 IV Installation of the Coupler cc ccccccseececeeeeeceeeeeseeeeeseeeeeseeeesseeessaeeesseeeseeeeeas 9 IV F OSIMONIMG Ol 1G COUPIO scicraccecaceaccocactatecaactacenacutacaecastacaacactadeceectaceoacctacecans 9 IV 2 Connecting the reference cable n nnnnannnunnnnnnnnennnnnennennnnnnnnnrrernrennrrnennen 9 IVS IDE Ee
2. To operate the fiber coupler with a spectrometry system all specified conditions have to meet the requirements Otherwise trouble or defects may occur Sensitive optical elements Please note the advice given below concerning the handling of sensitive optical elements Specification 4 Spare parts Only use original spare parts If it is necessary to change parts not listed in the following chapters please refer to art photonics customer service Do not repair or change parts which are not explicitly mentioned in this manual Components designed to fit together Always use the spectrometer units which have been assembled for you at the original installation Only use original spare parts If it is necessary to change parts not listed in the following chapters please refer to art photonics customer service Do not repair or change parts which are not explicitly mentioned in this manual Always contact art photonics Customer Services if you are considering an exchange Record the operating parameters of your spectrometer setup The operating parameters of the system should be checked defined and recorded each time a change is made to the measurement system e g change of parabolic mirrors precision sliders etc This can either be done by carrying out the measurements described in the following chapters or individually defined standard measurements 1 2 Safety type and class The modular spectrometer systems or accessories
3. e EE ele Dunn EE 9 WA 0 2 gt ee ele aO EE 10 Vie Service ANd Maintenance cece cceecccceeeeeceeeeeeeeeeseeeeesseeeeeseeeesseeeesseeeesseeeeseees 11 Vi How to store the Fiber Coupler safely 00nnn0nnnnunnnnnnnnennnnnnnnnnnnnnnnnnnnnne 11 V 2 SE Tute Bang le 11 V 3 SPAle OTe LACE 11 M TOUS NOOU eee 12 Vil AtacnmMmeENlS sivsseresccessnresneserenesinerners near rere ere E Ea KENEN r EESO 13 VI New safety regulations for servicing laboratory eouipment 13 VII 2 Confirmation on Decontammnaton 13 VII 3 Test Reports and Material Certificates cccccccceccesseeeseeeeeseeeeeseeeeesaeeees user manual 3 Specification introduction The Fiber Coupler iD1 FC is a product of art photonics company It is intended to attach any fibre cable or fibre probe terminated with SMA905 connectors to the spectrometer Nicolet iS5 from Thermo Scientific I 1 Safety Instructions These units are not designed for use in hazardous areas The units supplied should not be repaired by anyone other than art photonics engineers or technicians authorized by art photonics In case of operation trouble please address to our Customer service department using the form for Confirmation on Decontamination abbr Attachments art photonics GmbH Rudower Schaussee 46 12489 Berlin Germany phone 49 0 30 677 988 70 fax 49 0 30 677 988 799 e mail info artphotonics de web www artphotonics com Conditions for operation
4. QUIPMENT Dear Customer For instruments used in analytical laboratories e g bio chemical or pharmaceutical environment it cannot be ruled out that service personnel could be exposed to health risks by coming into contact with residues of hazardous substances especially when the instrument or accessories have been used for making measurements using radioactive infectious or toxic substances The current regulations and laws as well as the extended guidelines and norms stipulate that we as a manufacturer of measuring systems observe more stringent safety regulations in order to ensure the safety of our employees These regulations and laws include The chemicals ordinance for protection from hazardous substances The hazardous substances ordinance technical rules for hazardous substances The radiological protection ordinance The accident prevention regulations biotechnology safety tests concerning biological safety according to UVV VBG 102 e The guidelines of the professional associations working in contaminated areas Moreover the environmental regulations issued by the environmental protection and industrial inspection board as well as the quality assurance system DIN ISO 9001 which was awared to J amp M also have to be observed Therefore prior to allowing any repair work in your laboratory or before returning the instrument to us we would ask you either to carefully clean disinfect or decontaminate the instrument or
5. components to be serviced or confirm that the instrument or components have not come into contact with any hazardous substances The enclosed Confirmation on Decontamination should be filled out and attachet to the Shipping papers together with your repair order or handed out directly to our service technicians in your laboratory We are unable to commence repair work without a declaration that the instrument has been decontaminated Should the declaration not be received within three weeks we regret that we must for safety reasons return the instrument unrepaired at your cost For further questions please do not hesitate to contact us directly user manual 15 Attachments Confirmation on Decontamination If you return an instrument or component e g accessory to AP for sevicing purposes which is not properly decontaminated there will be a health risk for AP employees We therefore need your confirmation that the instrument or component was decontaminated and cleaned properly before shipping If the form below is not filled in accordingly and completely we will reject the instrument This is needed to protect our employees We kindly ask you for your understanding Instrument component Serial no Instrument or component has come into contact with radioactive substances How decontaminated cleaned Isotope chemical reagents How decontaminated cleaned R and S rules biological material How decontami
6. gth 136 mm Total height 74 mm without align handles 85 mm with alignment handles Total width 60 mm SMA height alignment 12 mm Axis to axis 76 mm between fiber connectors Connectors SMA905 Case material Aluminium alloy Weight 0 5 kg user manual 7 Specification SMA SUC LLLLL LLG E S SE Pa Uli p r r sh LZ Optical parts 1 2 1 Parabolic mirrors Diameter 27 mm Focus 15 x 30 mm Specification 8 lll Content of Delivery The Fiber Coupler iD1 FC package should include the following items 1 x Fiber Coupler 1 1 x iD1 accessory case 2 1 x Reference fiber cable 3 Fiber Coupler is mounted inside the iD1 accessory case Do not take the coupler out of the iD1 accessory Casel p e Zei 5 Z i Nj 7 Pe op user manual 9 Installation of the Coupler IV Installation of the Coupler The pictures below explain step by step how to insert and adjust the coupler Some important issues are mentioned as well The following picture shows which parts are needed to install the fibre coupler 1 Spectrometer iS5 2 Reference cables PIR 400 500 and CIR 250 300 3 iID1 accessory with art photonics coupler iD1 FC inside Do not take the coupler out of the iD1 case Don t touch the mirrors by hands It could result in poor coupling efficiency IV 1 Positioning of the coupler Insert the coupler into sample compartment of t
7. he spectrometer It should not move or rock IV 2 Connecting the reference cable The next step is to insert the reference cable connectors into SMA adaptors of the coupler The preparation is ready for the alignment of fibre coupler to get highest signal possible IV 3 Fiber Coupler alignment At first switch the spectrometer and computer on Start Omnic software and switch it on Expt set gt Bench gt Single Beam Figure 7 shows the alignment mode Single Beam Installation of the Coupler 10 Collect Bench Diagnostic Max 2 94 Min 0 00 Min Max Peak to peak a S ba H Sample compartment Detector Beamsplitter Source Recommended range Max range limit Min range limit Optical velocity Aperture 2000 Wavenumbers cm 1 Bava lS wg VJ Single beam Freeze Ereg F Tone C Help J Morven g Save J FSaveas f oK 2 ancetl The coupler is delivered with pre aligned mirrors Minor additional adjustment is only needed The alignment should start with changing the z axis position vertical position of SMA adaptors one by one When the highest signal is reached then adjust output mirror using two black screws on the left side Afterwards align the screws on the right side to optimise the mirror at the light source The whole alignment must be done carefully Don t align too fast because the response of detector is delayed Normally the adjustment can be done once then only slight correct
8. ion is necessary for any other attachment of fibre cables and probes However make the correction of optimal mirrors positions for better signal and reproducible measurement results IV 4 Storage configuration e Close the cover of the iD1 accessory case e Put the protective caps onto the windows on both sides of iD1 accessory case e Store the reference cable with the Fiber Coupler user manual 11 Installation of the Coupler V Service and Maintenance Vi How to store the Fiber Coupler safely If not in use then the Fiber Coupler should be stored in a dry place Protection against dust is recommended Store the reference cable with Fiber Coupler V 2 Cleaning of mirrors Clean the mirrors only with compressed air flow V 3 Spare parts Reference cable AP 10156 or AP 10158 on request Service and Maintenance 12 VI Trouble Shooting Too low signal Check the system using reference cable with known signal Check fibre ends quality at both ends of the cable probe Check surface of the parabolic mirrors Check if the connectors are in good condition No signal Check position of the iD1 accessory in the iS5 spectrometer user manual 13 Attachments Vil Attachments Vil 1 New safety regulations for servicing laboratory equipment Vil 2 Confirmation on Decontamination Form sheet for return Vil 3 Test Reports and Material Certificates Attachments 14 NEW SAFETY REGULATIONS FOR SERVICING LABORATORY E
9. nated cleaned specifiy contagious agents How decontaminated cleaned specify hereby confirm that the instrument or component specified above was not contaminated with any of the above mentioned substances reagents agents hereby confirm that the instrument or component specified above was decontaminated cleansed using the appropriate method Date signature please print EE address title
10. vironment store the coupler in dry places only No further safety measures are required Although the components are robust jolts and rough handling should be avoided 1 6 Handling fiber couplers and cables d Handle parabolic mirrors with care e Do not take the coupler out of iD1 case e Do not touch optical surface of parabolic mirrors with fingers napkin any tool The surface can be easily scratched resulting in reflection transmission through the coupler drop e Do not rinse fiber coupler Do not immerse fiber coupler into liquids The fiber coupler is not sealed in the iD1 accessory thus the penetration of water or chemicals inside the coupler will result in it s damage Ask the manufacturer for the advice if fiber coupler need cleaning A Handle fiber cable with care e For optical reference cable in use avoid tension torsion and bending for radius less than 50mm Hold the connector not cable protective tube when pulling it out of the adaptor For handling with other optical cables and probes refer to handling rules for them e Store fiber coupler which is not in use in its protective storage cartons e Prevent the drop of the coupler e Be careful inserting the fiber cable into the coupler Specification 6 ll Specifications Fiber Coupler iD1 FC is intended to attach any fibre cable or fibre probe terminated with SMA905 connectors to FTIR spectrometer Nicolet iS5 IN Mechanical parts Total len
11. were constructed and tested according our test procedures and left our factory in perfect technical condition according to related safety regulations If this condition is to be maintained and in order to guarantee safe operation you must comply with all advice and warning notes in this manual 1 3 Customer service and warranty With the exception of o rings and protective caps changes as well as the maintenance and service tasks mentioned in the following chapters it is not allowed to service or repair components or accessories In case of self service the guarantee by art photonics will be no longer valid Only the manufacturer and persons authorised by the manufacturer are permitted to carry out repairs Please contact Customer Services in case of problems with your system or individual components user manual 5 Specification 1 4 Operating conditions Install your device with Fiber Coupler in easily accessible place Avoid contact of inside of the coupler with water or chemicals Protect optic elements against dirt Environmental temperature for the coupler not for coupled equipment 0 C to 50 C Working temperature for the coupler not for coupled equipment 0 C to 50 C Do not use this Fiber Coupler in hazardous areas 1 5 Storage and Transport Before starting the accessory the specified temperature range has to be reached Therefore allow the accessory to acclimatize for at least 0 5 hours to its new en