1. Go to page 1 12 MB Multi rate DSLPipe DSLPipe CellPipe Description Voice model DSL Cell 20A ADSL CellPipe that only No Go to page 1 10 supports bridging Supports RFC1483 Multiprotcol over AALS DSL Cell 50A ADSL CellPipe that supports No Go to page 1 10 ATM over ADSL Supports RFC1483 Multiprotcol over AALS DSL Cell 50S SDSL CellPipe that supports No Go to page 1 16 ATM over SDSL Supports RFC1483 Multiprotcol over AALS DSL HSTB SDSL 2 3MB DSLPipe that only No Go to page 1 20 supports bridging DSL HST SDSL High Performance 2 3 No 1 8 DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Table 1 2 Checking DSLPipe CellPipe model continued DSLPipe CellPipe Description Voice model DSL HS SDSL High Performancel 5 MB No Go to page 1 12 Multi rate DSLPipe DSL S SDSL DSLPipe No Go to page 1 16 1 port DSL 2S SDSL DSLPipe No Go to page 1 18 2 port DSL ACAP RADSL CAP DSLPipe Yes with voice Go to page 1 14 splitter DSL DMT RADSL DMT DSLPipe No Go to page 1 14 For details on setting up the voice splitter see the DSLPipe CellPipe User s Guide DSLPipe CellPipe Quick Setup 1 9 Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL Cell 50A or DSL Cell 20A cables 1 Description Connect the yellow crossover Ethernet cable from the port labeled 10BT or LAN on the CellPipe to the E
2. Do not allow anything to rest on the power cord and do not locate the product where people will walk on the power cord Do not attempt to service this product yourself Opening or removing covers can expose you to dangerous high voltage points or other risks Refer all servicing to qualified service personnel General purpose cables are provided with this product Special cables which might be required by the regulatory inspection authority for the installation site are the responsibility of the customer vi DSLPipe CellPipe Quick Setup Important safety instructions 16 When installed in the final configuration the product must comply with the applicable safety standards and regulatory requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 17 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential might cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists In addition if the equipment is to be used with telecommunications circuits take the following precautions e Never install telephone wiring during a lightning storm e Never install telephone jacks in wet locations unless the jack is specifically designed for
3. 192 168 200 1 Rem Name COE Rem Addr 204 215 204 215 Route None Bridge Yes Ethernet gt Connections gt COE Active Yes Encaps FR Encaps options FR Prof frame relay DLCI 16 Ethernet gt Frame Relay gt COE Name frame relay Active Yes FR Type DTE Link Mgmt T1 617D DSLPipe CellPipe Quick Setup 3 23 Configuring the unit DSLPipe CellPipe Quick Setup DSL ACAP as COE Table 3 9 Configuring the DSL ACAP as COE Example Scenario as COE DSL ACAP Configuration Assume you are setting up the RADSL CAP DSLPipe for a bridged Frame Relay connection Note When you set up a DSLPipe for Frame Relay you must create a Connection profile and a Frame Relay profile Configure gt Chan Usage Leased Unused My Name COE My Addr 204 215 204 215 Rem Name CPE Rem Addr 192 168 200 1 24 Route None Bridge Yes Ethernet gt Connections gt CPE Active Yes Encaps FR Encaps options FR Prof frame relay DLCI 16 Ethernet gt Frame Relay gt CPE Name frame relay Active Yes FR Type DCE Link Mgmt T1 617D 3 24 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup DSL Cell 50A as CPE Table 3 10 Confiuging the CellPipe 50A as CPE Example Scenarios CellPipe Configuration 1 Assume you are setting up ATM Configure gt over ADSL with VPI 1 VCI 10 Chan Usage Leased Unused Assume you w
4. eee cece cee ceeeceeeeseeeeeeseeeaeceesaeenaes 1 4 Steps to setting up your DSLPipe CellPipe unt 1 7 Checking DSLPipe CellPipe model name 0 0 cece eeeeeceseeeeceeeeeeeeeeeeeeeeeeneeeaes 1 8 Connecting DSL Cell 50A or DSL Cell 20A cables eee eee eee eeeee 1 10 Connecting DSL HST or DSL HS cables o oo eee eee eee eseeeee cesses eeenaes 1 12 Connecting DSL ACAP or DSL DMT cables AA 1 14 Connecting the DSL Cell 50S or the DSL S cables wo eee eee eeeee 1 16 Connecting DSIE 28 Cables iensen saa a a E SEEE SSE 1 18 Connecting DSL HSTB cables oo eee ceseeseceeceseceseeseeeeeeseseeseaeeeaeeaee 1 20 Checking the activity of DSLPipe CellPipe LED lights 0 eeeee 1 22 Getting ready to configure ceeeeeeeeeeeeeeeneeeeeeeeeeeeeeeees 2 1 Getting ready to configure the DSLPipe or CellPipe unit eee 2 1 t ms you need iinr Mein cae ea aa eae nea 2 1 Connecting serial cable and setting up communications software 2 2 What S NOX tege EN 2 3 The DSLPipe CellPipe main Window oo eee cseceseeseceseeseceeeeeeeeeeeeseneeaeeeaes 2 3 StAtUs WINDOWS e aa a cue des sey sabes d e E EEE E 2 4 Navigating within the DSLPipe CellPipe window 0 0 0 0 ce ceeeseeceseeeseeeeeeeeeneeees 2 4 Opening A MENU EEN EEdEEEEAEEEEE EE 2 5 DSLPipe CellPipe Quick Setup ix Contents Changing parameters with text entries 0 eee cee ceeceseeeeceeeeeeeeneeees 2 6 Setting parameters with predefined values 200 0 eee ee eeeeeeeee
5. www ascend com for technical information product information and descriptions of available services Visit the FTP site at ftp ascend com for software upgrades release notes and addenda to this manual Obtaining technical assistance You can obtain technical assistance by telephone email fax modem or regular mail as well as over the Internet Enabling Lucent to assist you If you need to contact Lucent for help with a problem make sure that you have the following information when you call or that you include it in your correspondence e Product name and model e Software and hardware options e Software version e Whether you are routing or bridging with your Lucent product e Type of computer you are using e Description of the problem Calling Lucent from within the United States In the U S you can take advantage of Priority Technical Assistance or you can call to request assistance DSLPipe CellPipe Quick Setup iii Customer Service Priority Technical Assistance If you need to talk to an engineer right away call 900 555 2763 to reach the Priority Call queue The charge of 2 95 per minute does not begin to accrue until you are connected to an engineer Average wait times are less than three minutes Other telephone numbers For a menu of Lucent s services call 800 272 363 Or call 510 769 6001 for an operator Calling Lucent from outside the United States You can contact Lucent by
6. 6 Configuring the DSL HST as CPE continued Example Scenarios as CPE DSL HST Configuration 2 Assume you are setting up a DSL HST for a bridged Frame Relay connection Note When you set up a DSLPipe for Frame Relay you must create a Connection profile and a Frame Relay profile Configure gt Chan Usage Leased Unused My Name CPE My Addr 204 215 204 215 Rem Name COE Rem Addr 192 168 200 1 24 Route None Bridge Yes SDSL Line Rate 1552000 Unit Type CPE Ethernet gt Connections gt COE Active Yes Encaps FR Encaps options FR Prof frame relay DLCI 16 Ethernet gt Frame Relay gt COE Name frame relay Active Yes FR Type DTE Link Mgmt T1 617D 3 20 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup DSL HST as COE Table 3 7 Configuring the DSL HST as COE Example Scenarios as COE DSL HST Configuration 1 Assume you are setting up a DSL HST for Frame Relay with only IP routing enabled Note When you set up a DSLPipe for Frame Relay you must create a Connection profile and a Frame Relay profile Configure gt Chan Usage Leased Unused My Name COE My Addr 192 168 200 1 24 Rem Name CPE Rem Addr 204 215 204 215 Route IP Bridge No SDSL Line Rate 1552000 Unit Type COE Ethernet gt Connections gt CPE Active Yes Encaps FR Encaps options FR Prof f
7. DSL Cell 50A and the DSL Cell 50S units The CellPipes do not ship with a default configuration You must set up the CellPipes by choosing parameters available in the Configure menu When you choose values in the Configure menu you are choosing values that apply to the first connection profile Note A DSLPipe CellPipe connection profile contains all the settings required to talk to a remote machine For additional CellPipe connection profiles see the example scenarios page 3 25 The following shows possible values for the parameters in the Configure menu Configure Chan Usage Leased Unused My Name CellPipel My Addr 204 204 215 342 Rem Name COE1 Rem Addr 198 902 101 001 Encaps ATM You can choose ATM or PPP Mux Type ATM LLC You can choose ATM LLC or ATM VC Vpi You must specify a number Vci You must specify a number Route No Bridge Yes Send Auth N A Send PW N A Recv Auth N A Rev PW N A Save The CellPipes can be set up for one of the following encapsulations e RFC 1483 LLC Logical Link Control encapsulation or VC Virtual Circuit multiplexing for ATM AALS The default is ATM LLC e PPP over ATM AALS using LLC encapsulation or VC multiplexing In VC multiplexing only one protocol is allowed per session Up to eight sessions can be set up each with a unique VPI Virtual Path Identifier and VCI Virtual Circuit 3 6 DSLPipe CellPipe Quick Setup Configuring
8. Line Ch gt 00 000 System State UP Outgoing Call 20 000 Ethernet Up Rate 784000 20 100 Sessions 20 500 Dyn Stat gt 1 Active Link Up 12 1 32 RX Signal present gt Line Q 15db Good 20 300 WAN Stat 20 400 Ether Stat gt Rx Pkt 404 gt Rx Pkt 8 Tx Pkt 421 Tx Pkt 95 CRC ZS Col 0 00 100 Sys Option 00 400 HW Config gt Security Prof 1 RADSL Interface Software 6 10 gt Adrs 00c07b722bdc S N 7475332 Enet I F UTP Press Ctrl n to move cursor to the next menu item Press return to select it Press Tab to move to another window thick border indicates active window Status windows The eight windows on the right are the status windows Use the Tab key to make any status window active If a plus sign appears at the end of a line in a status window you can see more text by selecting the line and scrolling to the end of it If a and y appear at the end of the top or bottom lines in a status window you can press Ctrl N or the down arrow key or Ctrl P or the up arrow to display additional lines of text See the DSLPipe CellPipe Reference Guide and the DSLPipe CellPipe User s Guide for more information Navigating within the DSLPipe CellPipe window Note This section does not apply to the DSL Cell 20A and the DSL HSTB units 2 4 DSLPipe CellPipe Quick Setup Getting ready to configure DSLPipe CellPipe Quick Setup Follow these guidelines to navigate the DSLPipe CellPipe menu system Use t
9. are no operator serviceable parts within the unit Refer all servicing to trained service personnel Product installation should be performed by trained service personnel only Install only in restricted access areas in accordance with UL1950 C22 2 No 950 and IEC60950 The maximum recommended operating ambient is 104 F 40 C Allow sufficient air circulation or space between units when installed in a closed or multiple rack assembly Slots and openings in the cabinet are provided for ventilation To ensure reliable operation of the product and to protect it from overheating these slots and openings must not be blocked or covered Installation without sufficient airflow can be unsafe Equipment mounted in a rack should be distributed to prevent a possible hazardous condition due to uneven loading The rack should safely support the combined weight of all equipment This product weighs about 2 lbs DSLPipe CellPipe Quick Setup v Important safety instructions 10 11 12 13 14 15 The power source has to be adequately rated to assure safe operation of the equipment The building installation and or power source must provide overload protection Protective earth PE connection is essential to ensure safe operation before connecting to the power supply and telecommunication network Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter Use an outlet tester or a voltmete
10. is less than or equal to the maximum upstream rate DSLPipe CellPipe Quick Setup 3 7 Configuring the unit DSLPipe CellPipe Quick Setup Configuring the DSL Cell 20A The DSL Cell 20A unit performs bridging over ATM with LLC encapsulation It ships with a default VPI of 8 and a default VCI of 35 If you do not need to change these default settings just plug in the cables and you are ready to use the DSL Cell 20A unit DSL Cell 20A command line interface After you connect the cables and set up the communications software see Getting ready to configure the DSLPipe or CellPipe unit on page 2 1 the following appears on your VT100 terminal Boobase Version lt Version Number gt lt Date and Time gt RAM Size 4096 bytes DRAM POST Testing 4096 OK FLASH Intel 8M 1 ZYNOS Version lt Version Number gt lt Date and Time gt Press any key to enter debug mode within 3 seconds Version lt Version Number gt start lt hex address gt Length lt hex number gt Checksum lt hex number gt Compressed Length lt hex number gt Checksum lt hex number gt Initialize ch 0 Ethernet address lt MAC addresss gt Loading AADSL modem F W WAN Channel init done Press ENTER to continue From the VT100 emulation screen press the Enter key to see the lucent prompt The lucent prompt appears Displaying status To see the list of all the status commands available type the f
11. or the DSL HST model you must supply your own straight through cable e To configure the DSLPipe CellPipe you must supply your own serial cable Check the activity of DSLPipe CellPipe LED lights If you are configuring e aDSLPipe unit read the description of the default configuration e the CellPipe 50A or the CellPipe 50S read the information on configuring these pipes e the CellPipe 20A read the desciption of the default configuration To change the default configuration see the sample scenarios Before you can change the configuration you must establish a serial connection between your workstation and the DSLPipe CellPipe unit You must also have software for vt100 emulation Go to page page 1 8 page 1 10 page 1 12 page 1 14 page 1 16 page 1 18 page 1 20 page 1 22 page 3 2 page 3 13 page 3 6 page 3 8 page 3 18 Also see page 3 8 and page 3 13 DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Step Description For additional information refer to the DSLPipe CellPipe User s Guide and the DSLPipe CellPipe Reference Guide Go to page Checking DSLPipe CellPipe model name Before setting up the DSLPipe CellPipe check which DSLPipe CellPipe model you have The model number is printed on the back of the DSLPipe CellPipe Your setup procedure will vary slightly according to the model Table 1 2 Checking DSLPipe CellPipe model
12. to the items provided with the DSLPipe CellPipe unit you will also need the following An Ethernet interface For the DSLPipe to transmit data to and receive data from your computer you need a properly configured Ethernet interface for your computer The interface can be built into the computer as it is on many recent Dell Apple Macintosh and Macintosh compatible personal computers or it can be an add on circuit board or PCMCIA card PC card Follow the instructions for installing and configuring the interface that are included with your computer TCP IP or IPX software To communicate with a remote network your computer must have the necessary networking software often known as a stack A TCP IP stack lets you connect to the Internet and to other networks that use the same networking standards as the Internet Many operating systems include software for TCP IP If TCP IP software is not included in your operating system you need to obtain a separate TCP IP software package For information on configuring the TCP IP software see the documentation for your operating system or TCP IP software package An IPX stack lets you connect to Novell NetWare networks A WAN cable If you have a DSL 2S the model number is printed in the bottom of the box and you want to use both WAN ports to connect to two separate jacks you will need another WAN cable with RJ11 modular plug connectors 1 4 DSLPipe CellPipe Quick Setup Insta
13. CP client in a DSLPipe automatically performs the appropriate DHCP protocol procedure to get its configuration information The DSLPipe automatically receives its IP address netmask default gateway and TFTP server address from the remote device Note To see if you can use the DSLPipe plug and play capability check with your service provider Changing default configuration of DSLPipe units If you cannot use the plug and play capability you must modify the predefined settings to create your own connection profile s Note This section does not apply to the DSL HSTB unit For details on changing the configuration of the DSL HSTB unit see Configuring the DSL HSTB unit on page 3 13 Creating a connection profile for a Frame Relay connection To create a connection profile for Frame Relay you must at a minimum do the following 1 Assign values to the following in the Configure menu My Name My Addr Rem Name Rem Addr Route Bridge 2 Choose Configure gt Ethernet gt Connections and verify that Encaps FR 3 Choose Configure gt Ethernet gt Encaps options and assign values for the following DSLPipe CellPipe Quick Setup 3 3 Configuring the unit DSLPipe CellPipe Quick Setup FR Prof name of the Frame Relay Profile DLCI DLCI number for this profile Note You can set up multiple Frame Relay profiles or use the same Frame Relay profile in multiple connection profiles 4 Choose Eth
14. CellPipe model name 1 8 Connecting DSL Cell 50A or DSL Cell 20A cables 0 0 00 0 eee eee eee 1 10 Connecting DSL HST or DSL HS cables 0 0 0 0 cece eee 1 12 Connecting DSL ACAP or DSL DMT cables 00000 1 14 Connecting the DSL Cell 50S or the DSL S cables n n 00 0 0 0 eee ee eee eee 1 16 Connecting DSL 2S cables 0 0 eect eee nea 1 18 Connecting DSL HSTB cables 210 EE aces a lhe ed ER ERE Bie ded BE AL a Rs 1 20 Checking the activity of DSLPipe CellPipe LED bebes 1 22 What is the DSLPipe CellPipe The DSLPipe CellPipe unit is a high speed bridging and or routing device You can use a DSLPipe CellPipe unit to create a dedicated physical connection to Digital Subscriber Line DSL equipment at the phone company You first attach your computer or Ethernet hub to a DSLPipe CellPipe unit Then you connect one end of a DSLPipe CellPipe Quick Setup 1 1 Installing the unit DSLPipe CellPipe Quick Setup standard telephone line to the unit The other end connects to DSL equipment at the phone company Your DSL circuit is dedicated to your DSLPipe CellPipe unit With DSL you have the capacity to transfer data at very high rates The actual rate can vary according to the type of DSLPipe CellPipe you use the distance between the DSLPipe CellPipe and the DSL equipment and the line quality of the connection You can use DSL technology for Internet access telecommuting remote office connectivity multimed
15. Chan Usage Leased Unused My Name Bob My Addr 204 215 204 215 assigned the COE can assign an addres if not s Rem Name ex4 Rem Addr 10 10 10 10 Encaps PPP Mux Type ATM LLC Vpi 5 Vci 20 Route IP Bridge No Send Auth PAP Send PW lala Recv Auth N A Recv PW N A Rate Mode singlebaud SDSL Line Rate 784000 Unit Type CPE DSLPipe CellPipe Quick Setup 3 33 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 5 Assume you are setting up on demand PPP over ATM with Vpi set to 5 and Vci set to 20 The Data Rate parameter is set to 2320 Kbps and you are using the unit as CPE Assume you will be using a LLC connection with IP routing Assume you are using PAP authentication with the password lala Note The to the left of a field indicates that it is a required field You must fill in a value for the field Configure gt Chan Usage Switch Unused My Name Bob My Addr 204 215 204 215 if not assigned the COE can assign an address Rem Name ex5 Rem Addr 10 10 10 10 Encaps PPP Mux Type ATM LLC Vpi 5 Vci 20 Route IP Bridge No Send Auth PAP Send PW lala Recv Auth N A Recv PW N A Rate Mode singlebaud SDSL Line Rate 2320000 Unit Ty
16. HSTB unit is 9600 bps To change this value type the following lucent set baudrate lt bps gt Press the Enter key The baudrate can be any of the following 9600 bps 19200 bps 38400 bps 57600 bps or 115200 bps Changing the Frame Relay DLC The DSL HSTB unit ships with the default DLCI of 16 To change the DLCI enter the following lucent set fr dlci lt number gt Press the Enter key The DLCI can be any number between 16 and 991 This command changes the DLCI of the Frame Relay connection 3 16 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Changing the SDSL rate The DSL HSTB unit ships with the default SDSL rate of 2320 Kbps You can use any one of the following rates e 144 Kbps e 272 Kbps e 400 Kbps e 528 Kbps e 784 Kbps e 1168 Kbps e 1552 Kbps e 2320 Kbps To change the SDSL line rate enter the following lucent set sdsl rate lt Kbps gt Press the Enter key Autohunt option The DSL HSTB unit is automatically set to hunt for the line rate The unit tries different rates to sync up with the COE site Depending on the rate set at the COE side this might take a few minutes To force the DSL HSTB unit to connect at only a specified speed you can set the autohunt option to off Type the following lucent set autohunt off Press th Exiting the command line interface Enter key To exit the command line interface type e
17. Lucent Technologies Bell Labs Innovations DSLPipe CellPipe Quick Setup Part Number 7820 0597 003 For software version 8 0 October 1999 Copyright 1999 Lucent Technologies All Rights Reserved This material is protected by the copyright laws of the United States and other countries It may not be reproduced distributed or altered in any fashion by any entity either internal or external to Lucent Technologies except in accordance with applicable agreements contracts or licensing without the express written consent of Lucent Technologies Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of printing However information is subject to change Trademarks DSLPipe DSLTNT and CellPipe are trademarks of Lucent Technologies Other trademarks and trade names mentioned in this publication belong to their respective owners Ordering Information To order copies of this document contact your Lucent Technologies representative or reseller Support Telephone Numbers For a menu of support and other services call 800 272 3634 Or call 510 769 6001 for an operator Lucent Technologies Customer Service Customer Service Customer Service provides a variety of options for obtaining information about Lucent products and services software upgrades and technical assistance Finding information and software on the Internet Visit the Web site at http
18. N and power cables you are ready to start using your DSLPipe If you are changing the DSLPipe s default configuration you must establish a serial connection You will need the following A computer with a serial port To change the default configuration or monitor the DSLPipe you need a computer with a serial communication port capable of transmitting data at 9600 bits per second The serial communication port is normally one you could use to connect an external modem If you are not already familiar with your computer s serial ports refer to your computer s user guide for more information DSLPipe CellPipe Quick Setup 1 5 Installing the unit DSLPipe CellPipe Quick Setup If possible you should set aside a serial port for a permanent connection to the DSLPipe CellPipe If there are not enough serial ports for all the devices that need serial connections consider adding another serial port if you can With a permanent serial connection you can monitor the DSLPipe at any time manually connect to and disconnect from remote networks and make configuration changes whenever necessary If no serial port is currently free and you cannot add a serial port to your computer disconnect from one of the serial ports a device that you can temporarily do without such as an external modem A serial cable To connect the DSLPipe to your computer s serial port you need a serial cable a serial communication cable designed for c
19. d now display the DSLPipe CellPipe main window see page page 2 3 If it does not press Ctrl L to reload or refresh the screen The part of the screen you use to configure the DSLPipe CellPipe is on the left and looks like this Configure Chan Usage Leased Unused My Num A N A My Num B N A My Name My Addr Rem Name Rem Addr Note The DSL Cell 20A and the DSL HSTB units don t display the same software as the other DSLPipe CellPipe units What s next To learn how to navigate within the DSLPipe CellPipe menu system see page page 2 4 To see example configurations turn to page page 3 18 The DSLPipe CellPipe main window Note The DSL Cell 20A and the DSL HSTB units don t display the same user interface as the other DSLPipe CellPipe units See Configuring the DSL Cell 20A on page 3 8 and Configuring the DSL HSTB unit on page 3 13 for details DSLPipe CellPipe Quick Setup 2 3 Getting ready to configure DSLPipe CellPipe Quick Setup The DSLPipe CellPipe main window allows you to monitor the status of your DSLPipe CellPipe as well as configure all the connection profiles Note To learn how to configure your DSLPipe CellPipe see the examples on the next few pages To change parameters not shown in the examples see the DSLPipe CellPipe User s Guide and the DSLPipe CellPipe Reference Guide Edit Main Edit Menu 10 100 Line Status 00 200 06 39 10 Configure gt Unit Type CPE M31
20. d un type recommand par le fabricant Mettre au rebut les batteries usag es conform ment aux instructions du fabricant Warnung Die Batterie kann eventuell explodieren wenn sie nicht ordnungsgem ausgetauscht wird Ersetzen Sie die Batterie nur mit einer Batterie des gleichen oder eines hnlichen vom Hersteller empfohlenen Typs Entsorgen Sie gebrauchte Batterien gem den Anweisungen des Herstellers Mains Disconnect no power switch Caution The power supply cord is used as the main disconnect device Make sure that the outlet socket is located installed near the equipment and is easily accessible Attention Le cordon d alimentation est utilis comme interrupteur g n ral La prise de courant doit tre situ e ou install e proximit du mat riel et tre facile d acc s Vorsicht Zur sicheren Trennung des Ger tes vom Netz mu der Netzstecker gezogen werden Stellen Sie sicher da sich die Steckdose in der N he des Ger tes befindet und leicht zug nglich ist viii DSLPipe CellPipe Quick Setup Contents C stom r SELVICE EEN ae Sede aa anche asain dena N e iii Important safety instructions ssseesesseseeseeeseesrtsstssrtsttssttstessrsstesressresessessreseesreseesees v Installing the uni sesseueueueuerSeCNVEEEKNKEKEESENEREEEENEKENEEESEAEEEEEUNENNEn 1 1 What isthe DSLPipe Cell Pipe surigier EE a ata RS 1 1 Checkinis Dox Contents senisesse e e e E EN 1 2 Other items you need for installation oo
21. eeeeeseeeeseaeeeeeeneseeeeneenaes 3 13 DSL HSTB command line interface 2 eee ees cecseeesecseeesececeseeseeeseees 3 13 Displaying status ee 3 13 Displaying Frame Relay status 0 0 00 cece eeceseeeeeeeeeeeeeseeeeecaeeeaeeeeeaees 3 14 Displaying the Frame Relay DC 3 15 Displayime SDSL E 3 16 Changing configuration information 0 cece seeeeceeeeeeceeeeeeeeeeeseeeneeaes 3 16 Changing the console baud rate eee eeeeeeeeeeeecaeeeseceeeneceeeseeneees 3 16 Changing the Frame Relay DLCT 0 eee cee eeeceeeeeeceeeneeneeaees 3 16 Changing the SDSL rate oo eee eeeeeeeceeeecaecnaecneceaeeeenseeseeneees 3 17 Exiting the command line interface oo eee eeeeseeereeeeceeceeeaeceseeseeneens 3 17 Example configurations 0 0 ec ceesecssessecsecsseeseceseeecesceseeseeeseseaeeaeeeaecaaeeaesnaeeaes 3 18 DSL HS Las CPE EE 3 19 DSL HST s EE 3 21 DSL ACAP as EE 3 23 DSL ACAP as COE eini ie ka ea Melia A ORAS 3 24 DSE Cell250A as CRE a3 sssestccvss sos siteesscebsaehsck ssisees ie eeano rrei p sake ip nisa ase pie Tepsi 3 25 xX DSLPipe CellPipe Quick Setup Contents RK ENEE 3 29 DSLPipe CellPipe Quick Setup xi Contents xii DSLPipe CellPipe Quick Setup Installing the unit 1 What is the DSLPipe CellPipe AER eek Se ee pe bh bee eg bebe e LS 1 1 Checking box Contents EEN Eeer E tment 1 2 Other items you need for installation 0 0 eect ee 1 4 Steps to setting up your DSLPipe CellPipe unt 1 7 Checking DSLPipe
22. eeneeeeeenee 2 6 Saving or discarding your Changes 0 ee eceseeecseessecseeesececeseeseeeseeeeees 2 6 Configuring the unit cccccccesseeeeeeeeseeeceeeeeeesseeeeeeeeneeeeees 3 1 Configuring the DSLPipe units eee eeceseeeeceeeeeeeeeeeeeecneesaecaecaecneseseeaeees 3 2 Plug and Play capability 00 eeececreecseceeeeseceeceseceeceseseeeeaeeeeeeaeeees 3 3 Changing default configuration of DSLPipe units 00 eee eeeeee ce eeee 3 3 Creating a connection profile for a Frame Relay connection 0ses1 3 3 Creating a connection profile for a PPP connection cece eeeeeeee 3 4 Configuring the DSL Cell 50A and the DSL Cell 50S units 000 3 6 Traffic shaping options for the CellPipes A 3 7 Configuring the DSL Cell 20A oe senioriem i eeto r EE E EEEa a SeS 3 8 DSL Cell 20A command line interface esesseeeeeseeereeeeeeeesrerrsesresrssesreseeees 3 8 EI O EE EE 3 8 Displaying ATM status oc ee cceseeeeecneecsecseeaeceecseceeceseeeeeeeeeeeeaeeees 3 9 Displaying RE E 3 10 Changing configuration information 0 ele eee cesses ceeeeeeceeeeeeeeeeeaeeeneeaee 3 11 Changing the console baud rate 0 eee cece ceeceseeeeceseeeeeeeeeeeeeneeeeeees 3 11 Changing the VPI and VCI oo ceesececsseeseceseeseceeceseeeeeeeeeeeeeees 3 12 Changing the MUX type oo eee csseeseceeeseceeceeeeeenseteeseseeeeseaeeeeeeas 3 12 Exiting the command line interface oo ee eee eeeeeeecseesseceeceseeeeeeeeeeeees 3 12 Configuring the DSL HSTB unit oo cece ceecese
23. ernet gt Frame Relay gt connection the connection is the FR Prof name you assigned in the previous step and assign values to all the parameters in the menu 20 501 DSLFrame Name DSLFrame Active Yes Call Type Nailed FR Type DTE Nailed Grp 1 5 Optional You may need to choose Ethernet gt Mod Config gt Ether Options and turn Proxy Mode to Off Check with your service provider 6 Save all your settings before you exit the DSLPipe main menu Creating a connection profile for a PPP connection Unless you are setting up the DSLPipe 2S which has two WAN ports you can only create one connection profile for a PPP connection To create a connection profile for PPP you must at a minimum do the following 1 Assign values to the following in the Configure menu My Name My Addr Rem Name Rem Addr Route Bridge Send Auth Send PW Recv Auth Recv PW Choose Configure gt Ethernet gt Connections Set Encaps PPP Choose Ethernet gt Frame Relay gt connection Set Active No 3 4 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup 4 Optional You may need to choose Ethernet gt Mod Config gt Ether Options and turn Proxy Mode to Off Check with your service provider 5 Save all your settings before you exit the DSLPipe main menu DSLPipe CellPipe Quick Setup 3 5 Configuring the unit DSLPipe CellPipe Quick Setup Configuring the
24. euse last addr N A Reuse addr timeout N A 3 36 DSLPipe CellPipe Quick Setup
25. ext page DSLPipe CellPipe Quick Setup 3 31 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 3 Continued Ethernet gt Connections gt ex3 Station ex3 already assigned in the Configure menu Active Yes set to Yes when saved in the Config ure menu Encaps ATM already assigned in the Configure menu Route IP No Route IPX No Bridge Yes already assigned in the Configure menu Dial brdcast Yes Encaps options MUX Type ATM LLC already assigned in the Configure menu vpi 5 already assigned in the Configure menu vci 20 already assigned in the Configure menu Service Type Constant Service Rate 1000 Inverse ARP N A 3 32 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 4 Assume you are setting up nailed PPP over ATM with Vpi set to 5 and VCI set to 20 The Data Rate parame ter is set to 784 Kbps and you are using the unit as CPE Assume you will be using a LLC connection with IP routing Assume you are using PAP authentication with the pass word lala Note The to the left of a field indicates that it is a required field You must fill in a value for the field Configure gt
26. g the DSL Cell 20A on page 3 8 Configuring the DSLPipe units All DSLPipe units ship with a default configuration If you are setting up the DSLPipe to bridge and use Frame Relay you may not have to change the configuration You may be able to start using the DSLPipe after plugging in the cables See Plug and Play capability on page 3 3 Check with your service provider to see if you need to change the configuration Note The CellPipes do not ship with a default configuration The default configuration uses the following settings Table 3 1 Default DSLPipe configuration Menu Configure Encaps Options Ethernet gt Connections Ethernet gt Connections gt Ethernet gt Frame Relay Defaults Route None Bridge Yes Station DSLPipe Active Yes Encaps FR FR Prof DSLframe DLCI 16 ame DSLframe Active Yes FR Type DTE Link Mgmt T1 617D The default configuration is an example of a connection profile A DSLPipe connection profile contains all the settings required to talk to a remote machine 3 2 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Plug and Play capability The Ascend Plug and Play is a set of features that allows you to set up your DSLPipe quickly and easily The Plug and Play feature is automatically enabled in your DSLPipe The Plug and Play capability is based on a default Frame Relay configuration and a DHCP client The DH
27. g the DSL Cell 20A on page 3 8 and Configuring the DSL HSTB unit on page 3 13 Getting ready to configure the DSLPipe or CellPipe unit Before you can configure your DSLPipe CellPipe unit you must establish a serial connection to the unit Items you need e You need a serial cable that can plug into an available enabled serial port on your computer The other end of the cable must have a male DB 9 connector to fit the serial port connector on the back of the DSLPipe CellPipe or it must fit into the supplied DB 25 to DB 9 adapter If your computer is a Macintosh the cable must fit the modem port s nine pin mini DIN connector e You also need communications software that supports VT100 emulation DSLPipe CellPipe Quick Setup 2 1 Getting ready to configure DSLPipe CellPipe Quick Setup Connecting serial cable and setting up communications software To establish a serial connection proceed as follows 1 Use a serial cable to connect your computer s serial or modem port to the terminal port on the back of the DSLPipe CellPipe Use a communications program such as HyperTerm PROCOMM PLUS Zterm or any other program that supports VT100 terminal emulation to open a session directly with the port to which the DSLPipe CellPipe is connected Since the DSLPipe CellPipe connects directly to DSL equipment in the telephone company s central office you do not need to dial a telephone number Set your communication
28. he Up and Down arrow keys to navigate up and down through the menus A v at the end of the bottom line of a menu or status window listing indicates that more lines follow A at the end of the top line indicates additional lines above You can also use Ctrl N and Ctrl P oe enter Use Enter to do any of the following e Cycle through available values for a parameter e Open an input field for a parameter that doesn t have preset values e Move to the next field to make a selection or keep an entry esc Use the Esc key to exit a menu You always have the choice of saving or discarding your changes before exiting Opening a menu To open a menu select it by placing the cursor gt in front of the item and pressing Enter Main Edit Menu gt Configure 00 000 20 000 System Ethernet To move the cursor down press Ctrl N next or the Down Arrow key To move it up press Ctrl P previous or the Up Arrow key DSLPipe CellPipe Quick Setup 2 5 Getting ready to configure DSLPipe CellPipe Quick Setup With the exception of parameters designated N A not applicable you can edit all parameters in any menu N A indicates that a parameter does not apply based on the value of parameter it is subordinate to or based on a service not currently available on your system Changing parameters with text entries To edit text such as a password move the cursor to the para
29. ia and videoconferencing ISP Corp Site DSLPipe Cell Pipe Central Office IP ATM Frame Relay etc Satellite Office SSP Pipe Figure 1 1 Example of DSLPipe CellPipe setup This Quick Setup shows you how to connect the DSLPipe CellPipe to your workstation or Ethernet hub If you are using a DSLTNT at the central office refer to the DSLTNT documentation for details on setting it up Checking box contents The box in which you received your DSLPipe CellPipe should contain the items shown in Table 1 1 1 2 DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup If you want to set up a DSL ACAP or DSL DMT for voice traffic you must obtain a separate voice splitter package For details on setting up the voice splitter with your DSLPipe see the DSLPipe CellPipe User s Guide Table 1 1 Box contents 1 DSLPipe CellPipe unit 2 10Base T Ethernet crossover cable yellow The DSL HST and the DSL HS units ship with one straight through cable 3 DSL WAN cable with RJ11 modular plug connectors blue Note If you have a DSL 2S you may need to supply a second WAN cable 4 DB 25 to DB 9 serial adapter Power supply DSLPipe CellPipe manuals including Quick Setup User s Guide and Reference Guide DSLPipe CellPipe Quick Setup 1 3 Installing the unit DSLPipe CellPipe Quick Setup Other items you need for installation In addition
30. ill be using a VC connection with IP routing My Addr 204 215 204 215 Encaps ATM Mux Type ATM VC Vpi 1 Vci 10 Configure gt Ethernet gt Connections gt Station ex1 Active Yes Encaps ATM Dial N A Route IP Yes Bridge No Dial brdcast N A Ip options LAN Adrs 10 10 10 10 Telco options Call Type Nailed Group 1 DSLPipe CellPipe Quick Setup 3 25 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 10 Confiuging the CellPipe 50A as CPE Example Scenarios CellPipe Configuration 2 Assume you are setting up ATM Configure gt oyver ADSL yiti VEI S E Chan Usage Leased Unused Assume you will be using a LLC connection with bridging Also My Addr 204 215 204 215 assume that you want to specify a Encaps ATM constant rate of 1000 cells second Mux Type ATM LLC Vpi 5 Vci 20 Ethernet gt Connections gt Station ex1 Active Yes Encaps ATM Dial N A Route IP No Bridge Yes Dial brdcast Yes Encaps options MUX Type ATM LLC vpi 5 vei 20 Service Type Constant Service Rate 1000 Telco options Call Type Nailed Group 1 3 26 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3 10 Confiuging the CellPipe 50A as CPE Example Scenarios CellPipe Configuration 3 Assume you are setting up nailed PPP over ATM with VPI 5 VCI 20 Assume yo
31. ion information Using the command line interface of the DSL Cell 20A you can change the console baud rate and the VPI or VCI values You can also change the ATM encapsulation from LLC to VC multiplexing Changing the console baud rate The default value at which you connect to the DSL Cell 20A is 9600 bps To change this value type the following lucent set baudrate lt bps gt Press the Enter key The baudrate can be any of the following 9600 bps 19200 bps 38400 bps 57600 bps or 115200 bps Changing the VPI and VCI The DSL Cell 20A ships with the default VPI of 8 and the default VCI of 35 To change the VPI or VCI enter the following DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup lucent set atm vpi lt number gt Press the Enter key or lucent set atm vci lt number gt Press the Enter key This changes the VPI or VCI number Changing the MUX type The DSL Cell 20A ships with the LLC encapsulation as the default To change the LLC encapsulation default to VC multiplexing type the following lucent set atm mux vc Press the Enter key To return to LLC type the following lucent set atm mux llc Press the Enter key In VC multiplexing the bridged packets will not be encapsulated in the LLC header In LLC encapsulation the LLC header specifies the protocol being transmitted Exiting the command line interface To exit the command line inte
32. l the Frame Relay commands available type the following lucent show fr DSLPipe CellPipe Quick Setup 3 13 Configuring the unit DSLPipe CellPipe Quick Setup The following list appears show fr Display help information show fr help Display help information show fr stats Display Frame Relay information show fr dlci Display all DLCI information Displaying Frame Relay status To see statistics on the Frame Relay connection type the following lucent show fr stats The following list displays Name Type Status MTU InFrame OutFrame DSLFrame DTE Up 1532 215 219 Table 3 4 provides a description of each field Table 3 4 Frame Relay status screen Fields Description Name Name of the DSL HSTB unit The default is DSLFrame Type DTE or DCE The unit is always configured as DTE Status Either Up or Down Up means the Frame Relay link is up Down means the Frame Relay link is down MTU Maximum Transmission Unit size InFrame The number of received packets sent by the unit since the connection came up 3 14 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3 4 Frame Relay status screen Fields Description connection came up OutFrame The number of packets sent by the unit since the Displaying the Frame Relay DLC To display the Frame Relay DLCI type the following lucent show fr dlci The follo
33. lling the unit DSLPipe CellPipe Quick Setup Straight through Ethernet cables With the exception of the DSL HST and the DSL HS all DSLPipes CellPipes ship with one crossover Ethernet cable The DSL HST and the DSL HS ship with one straight through cable Note If you re connecting a single computer to the DSLPipe CellPipe and the computer has a 10Base T twisted pair Ethernet interface you don t need any additional Ethernet cabling In this case you can use the special crossover cable included with the DSLPipe CellPipe If you re connecting a 10Base T Ethernet network that includes a hub you need a standard 10Base T cable to connect the DSLPipe CellPipe to the 10Base T hub for the network and another standard 10Base T cable for connecting the computer to the hub Note that you cannot use the 10Base T crossover cable included with the DSLPipe CellPipe for these connections You can use the crossover cable only for a direct connection between a computer and the DSLPipe not for a connection to a 10Base T hub For Thicknet 10Base 5 or Thinnet 10Base 2 Ethernet networks consult the documentation for your network for information about proper cables and termination Items needed for establishing a serial connection If you are not using one of the CellPipes and you want to keep the DSLPipe s default configuration see page page 3 2 you do not have to establish a serial connection After connecting the Ethernet WA
34. meter and press Enter An edit field opens delimited by brackets A blinking text cursor appears in the brackets indicating that you can type in text If the field already contains text it is cleared when you type a character To modify only a few characters of existing text use the arrow keys to position the cursor then delete or overtype the characters To close the edit field and accept the new text press Enter Setting parameters with predefined values You can change the value of a parameter with predefined values by placing the cursor beside the parameter and pressing Enter until the correct value appears To select a value move to the next field or exit the menu Saving or discarding your changes When you have finished editing press the Esc key If you have entered or changed any parameters the Exit menu appears EXIT gt O ESC Don t exit 1 Exit and discard 2 Exit and save You can save your changes by choosing the Exit and Save option and pressing Enter or by pressing 2 2 6 DSLPipe CellPipe Quick Setup Configuring the unit 3 Configuring the DSLPipe unt 3 2 Configuring the DSL Cell 50A and the DSL Cell 50S unt 3 6 Configuring the DSL Cell 20A s ieron a a cece ences 3 8 Configuring the DSL HSTB unit 0 0 ce eee 3 13 Example configurations 0 0 0 eee E E E EE A E 3 18 Many of the DSLPipe and CellPipe units share a similar user interface The main configuration window is described i
35. n The DSLPipe CellPipe main window on page 2 3 The DSL HSTB and the DSL Cell 20A units however use a command line interface for displaying status and changing configuration For more details on using this interface see the sections on Configuring the DSL Cell 20A on page 3 8 and Configuring the DSL HSTB unit on page 3 13 All DSLPipe units ship with a default Frame Relay configuration See Configuring the DSLPipe units on page 3 2 for details If you do not need to change the default configuration just plug in the cables and your DSLPipe unit is ready for use If you need to change the configuration see Changing default configuration of DSLPipe units on page 3 3 Since the DSL HSTB unit uses a command line interface instead of menus the procedure for changing the default configuration of this unit is not the same as the procedure for changing the default configuration of the other units See Configuring the DSL HSTB unit on page 3 13 The DSL Cell 50S and the DSL Cell 50A units do not ship with a default configuration See Configuring the DSL Cell 50A and the DSL Cell 50S units on page 3 6 for details DSLPipe CellPipe Quick Setup 3 1 Configuring the unit DSLPipe CellPipe Quick Setup The DSL Cell 20A ships with a default configuration The unit is set up to bridge with ATM LLC encapsulation The VPI is set to 8 and the VCI is set to 35 If you want to change these defaults see Configurin
36. ollowing lucent show atm 3 8 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup The following list appears show atm Display help information show atm help Display help information show atm stats Display ATM information Displaying ATM status To see statistics on the ATM connection type the following lucent show atm stats The following list displays VPI 8 VCI 35 input pkts 0 input OK pkts 0 output pkts 0 output OK pkts 0 input cells 0 input OK cells 0 output cells 0 output OK cells 0 pad error 0 CRC error 0 cpi error 0 length error 0 CA ais Ca 0 4 eet tx 0 4_lpb_rx O f4_lpb_tx 0 f5_ais_rx 0 f5_rdi_tx 0 5_lpb_rx O 5_lpb_tx 0 Table 3 2 describes each field in the list that displays Table 3 2 Fields in the ATM status screen Fields Description VPI Virtual Path Identifier The default is 8 DSLPipe CellPipe Quick Setup 3 9 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 2 Fields in the ATM status screen Fields Description VC Virtual Circuit Identifier The default is 35 input pkts input OK pkts Number of packets received by the unit since the connection became active The input pkts value should match the input OK pkts value output pkts output OK pkts Number of packets sent by the unit since the connection became active The output pkts value should match the output OK pkt
37. onnecting an external device The cable must be a high speed cable that is one that supports the hardware handshaking technique used by almost all recently manufactured modems This cable must have the appropriate plug for connecting to a serial communication port on your computer and either a 9 or 25 pin male D connector at the other end Communications software To configure and monitor the DSLPipe you need communications software for your computer This software must be able to e Emulate a VT100 terminal e Make a direct connection to the DSLPipe through the serial port to which the DSLPipe is connected Most communications software that you purchase separately such as the PROCOMM PLUS program for Microsoft Windows work reliably For Macintosh computers a shareware communications program ZTerm works well You can also use the Terminal program included with Microsoft Windows 3 1 and the HyperTerm program included with Microsoft Windows 95 1 6 DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Steps to setting up your DSLPipe CellPipe unit To set up your DSLPipe CellPipe perform the following steps Step 1 Description Check DSLPipe CellPipe model The model name is printed on the bottom of the DSLPipe CellPipe box Connect the cables as required for your DSLPipe CellPipe model e Ifyou are connecting to an Ethernet hub and you are not using the DSL HS
38. p Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL HST or DSL HS cables continued Illustration Description 3 Connect the power cable to the DSLPipe and plug the other end into a wall outlet Connect to the wall outlet last There is no power switch Connecting the power cable turns on the DSLPipe Optional To change the DSLPipe default configuration connect a serial cable from the DSLPipe to your computer You can use the adapter that is provided You must provide your own serial cable After connecting the cables go to page 1 22 to check light activity DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL ACAP or DSL DMT cables 1 Description Connect the yellow crossover Ethernet cable from the port labeled 1 0BT on the DSLPipe to the Ethernet adapter in your computer To connect the DSLPipe to an Ethernet hub use your own straight through Ethernet cable Connect the blue WAN cable to the port labeled WAN on the DSLPipe and plug the other end into the wall jack DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL ACAP or DSL DMT cables continued Description Illustration 3 Connect the power cable to the DSLPipe and plug the other end into a wall outlet Connect to the wall outlet last There is no power switch Connec
39. pe CPE 3 34 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 6 Assume you are using NAT 10 10 10 10 is the gateway address You are setting up ATM over SDSL with Vpi set to and Vci set to 10 The Data Rate parameter is set to 528 Kbps and you are using the unit as CPE Assume you will be using a VC connection with IP routing Note The to the left of a field indicates that it is a required field You must fill in a value for the field Configure gt Chan Usage Leased Unused My Name My Addr 204 215 204 215 address belongs to the local sub net Rem Name ex6 Rem Addr 10 10 10 10 Encaps ATM Mux Type ATM VC Vpi 1 Vci 10 Route IP Bridge No Send Auth N A Send PW N A Recv Auth N A Recv PW N A Rate Mode singlebaud SDSL Line Rate 528000 Unit Type CPE continued on the next page DSLPipe CellPipe Quick Setup 3 35 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 6 Continued Ethernet gt NAT Routing Yes Profile ex6 VC address 10 10 10 100 use the static address assigned by your service provider LAN N A Static Mappings Def Server N A R
40. ptions Call Type Switched Group N A Interface options MUX Type ATM LLC vpi 5 vei 20 Service Type Unspecified Service Rate 0 3 28 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup DSL Cell 50S as CPE Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 1 Assume you are setting up only one Connection profile with the Data Rate parameter set to 144 Kbps The unit is functioning as CPE You are setting up ATM over SDSL with Vpi set to and Vci set to 15 Assume you will be using a VC connection with bridging Note The to the left of a field indicates that it is a required field You must fill in a value for the field Configure gt Chan Usage Leased Unused My Name My Addr Rem Name Rem Addr Encaps ATM exl Mux Type ATM VC Vpi 1 Vci 15 Route None Bridge Yes Send Auth N A Send PW N A Recv Auth N A Recv PW N A Rate Mode singlebaud SDSL Line Rate 144000 Unit Type CPE DSLPipe CellPipe Quick Setup 3 29 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 2 Assume you are setting up ATM over SDSL with Vpi set to 1 and Vci set to 10 The Data Rate parameter is set to 528 Kbps and you are using the unit as CPE Assume yo
41. r to check the ac receptacle for the presence of earth ground If the receptacle is not properly grounded the installation must not procede until a qualified electrician has corrected the problem If the power supply is fed from a power source with no protective earthing path such as in certain Nordic countries connect an earth grounded copper wire to the dedicated wiring terminal marked with PE symbol on the chassis The minimum size of the wire for a Pipeline unit with rated input current not exceeding 6A is AWG 18 and cross sectional area 0 75 mm Models with ac power inputs are intended for use with a single phase three wire power cord which includes earthing conductor For models with dc power inputs the protective earth connection must be established by using the dedicated earthing terminal marked with the PE symbol or if provided the earthing pin of the input terminal block Models with dc power inputs must be connected to a 48V dc supply source that is electrically isolated from the ac source in accordance with UL1950 C22 2 No 950 and IEC60950 For products installed in Nordic countries except Central Office equipment a type B plug or permanent connection must be used for connections to the main power supply Before installing wires to the dc power terminal block verify that these wires are not connected to any power source Installing live wires that is wires connected to a power source is hazardous
42. rame relay DLCI 16 Ethernet gt Frame Relay gt CPE Name frame relay Active Yes FR Type DCE Link Mgmt T1 617D DSLPipe CellPipe Quick Setup 3 21 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 7 Configuring the DSL HST as COE continued Example Scenarios as COE DSL HST Configuration 2 Assume you are setting up a DSL HST for bridged Frame Relay connection Note When you set up a DSLPipe for Frame Relay you must create a Connection profile and a Frame Relay profile Configure gt Chan Usage Leased Unused My Name COE My Addr 192 168 200 1 24 Rem Name CPE Rem Addr 204 215 204 215 Route None Bridge Yes SDSL Line Rate 1552000 Unit Type COE Ethernet gt Connections gt CPE Active Yes Encaps FR Encaps options FR Prof frame relay DLCI 16 Ethernet gt Frame Relay gt CPE Name frame relay Active Yes FR Type DCE Link Mgmt T1 617D 3 22 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup DSL ACAP as CPE Table 3 8 Configuring the DSL ACAP as CPE Example Scenario as CPE DSL ACAP Configuration Assume you are setting up the RADSL CAP DSLPipe for a bridged Frame Relay connection Note When you set up a DSLPipe for Frame Relay you must create a Connection profile and a Frame Relay profile Configure gt Chan Usage Leased Unused My Name CPE My Addr
43. rface type exit at the prompt lucent exit 3 12 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Configuring the DSL HSTB unit The DSL HSTB unit performs bridging over a Frame Relay connection It supports symmetrical transmission of 2 3 Mbps It ships with the DLCI set to 16 If you do not need to change these default settings just plug in the cables and you are ready to use the DSL HSTB unit DSL HSTB command line interface After you connect the cables and set up the communications software see Getting ready to configure the DSLPipe or CellPipe unit on page 2 1 the following appears on your VT100 terminal Boobase Version lt Version Number gt lt Date and Time gt RAM Size 4096 bytes DRAM POST Testing 4096 OK FLASH Intel 8M 1 ZYNOS Version lt Version Number gt lt Date and Time gt Press any key to enter debug mode within 3 seconds Version lt Version Number gt start lt hex address gt Length lt hex number gt Checksum lt hex number gt Compressed Length lt hex number gt Checksum lt hex number gt Initialize ch 0 Ethernet address lt MAC addresss gt Start to initialize SDSL Start to configure SDSL SDSL Channel Configuration Press ENTER to continue From the VT100 emulation screen press the Enter key to see the lucent prompt The lucent prompt appears Displaying status To see the list of al
44. s software to connect with the following settings Note If you are not already familiar with the settings listed see the documentation for your communications software If you re using the software for the first time going through an online or printed tutorial if the software includes one is a good way to get started Direct connection Tell the software that there is a serial cable connecting the DSLPipe CellPipe directly to the computer Serial port Specify which of the computer s serial ports the software uses If the only serial port available is currently used by an internal modem you may need to use your computer s setup software to specify an external connector for the port that will be used in place of the internal modem In some cases you also may need to remove the modem See the manual for the modem and your computer s user manual for details Flow control Turn off software flow control XON XOFF and if possible hardware flow control RTS CTS Specify None Terminal type Specify VT100 Duplex If the software lets you choose specify Full Because this is by far the most common choice most communications software sets this by default Bits per second Specify 9600 Data bits Specify 8 Stop bits Specify 1 Parity Specify None 2 2 DSLPipe CellPipe Quick Setup Getting ready to configure DSLPipe CellPipe Quick Setup 4 Your communications program shoul
45. s value input cells input OK cells Number of cells received by the unit since the connection became active The input cells value should match the input OK cells value output cells output OK cells Number of packets sent by the unit since the connection became active The output cells value should match the output OK cells value f 4 rx If these numbers increment quickly in a short period of 5 tx time it means that the CO site is sending signals about problems in the ATM backbone You may find that the Internet connection is not stable Displaying ADSL status To see statistics on the ATM connection type the following lucent show adsl stats The following screen of information displays ADSL Chipset Version lt Version gt ANSI Version Line Status lt Version gt Up Upstream Speed lt Kbps gt 3 10 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Downstream Speed lt Kbps gt Table 3 3 Fields in the ADSL Status screen Fields Description ADSL Chipset Version Version number of the chipset ANSI Version ANSI version number Line Status Up or Down Up if the connection is active Down if the connection is inactive Upstream Speed Speed from the DSL Cell 20A unit to the CO site Downstream Speed Speed from the CO site to the DSL Cell 20A unit Changing configurat
46. talling the unit DSLPipe CellPipe Quick Setup Connecting DSL HSTB cables Description Illustration 1 Connect the yellow crossover Ethernet cable from the port labeled LAN on the DSLPipe to the Ethernet adapter in your computer Note To connect the DSLPipe to an Ethernet hub use your own straight through Ethernet cable 2 Connect the blue WAN cable to the port labeled WAN on the DSLPipe and plug the other end into the wall jack 1 20 DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL HSTB cables Description Illustration 3 Connect the power cable to the DSLPipe and plug the other end into a wall outlet Connect to the wall outlet last There is no power switch Connecting the power cable turns on the DSLPipe Optional To change the DSLPipe default configuration connect a serial cable from the DSLPipe to your computer You can use the adapter that is provided You must provide your own serial cable After connecting the cables go to page 1 22 to check light activity DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Checking the activity of DSLPipe CellPipe LED lights Observe the activity pattern of the lights at the front of the DSLPipe CellPipe to verify that your unit is connected properly When all the cables are connected verify that e The pwr light
47. telephone from outside the United States at one of the following numbers Telephone outside the United States 510 769 8027 Austria Germany S witzerland 33 492 96 5672 Benelux 33 492 96 5674 France 33 492 96 5673 Italy 33 492 96 5676 Japan 81 3 5325 7397 Middle East Africa 33 492 96 5679 Scandinavia 33 492 96 5677 Spain Portugal 33 492 96 5675 UK 33 492 96 5671 For the Asia Pacific Region you can find additional support resources at http apac ascend com Obtaining assistance through correspondence Lucent maintains two email addresses for technical support questions One is for customers in the United States and the other is for customers in Europe the Middle East and Asia If you prefer to correspond by fax BBS or regular mail please direct iv DSLPipe CellPipe Quick Setup Important safety instructions your inquiry to Lucent s U S offices Following are the ways in which you can reach Customer Service Email from within the U S support ascend com Email from Europe the Middle East or Asia EMEAsupport ascend com Fax 510 814 2312 Customer Support BBS by modem 510 814 2302 Write to Lucent at the following address Attn Customer Service Lucent Technologies 1701 Harbor Bay Parkway Alameda CA 94502 3002 Important safety instructions A GENERAL 1 Read and follow all warning notices and instructions marked on the product or included in the manual There
48. the unit DSLPipe CellPipe Quick Setup Identifier In LLC encapsulation the LLC header specifies the protocol being transmitted Traffic shaping options for the CellPipes The traffic shaping feature in the CellPipes allows you to specify the transmit rate and priority for each VC you define You specify traffic shaping by choosing a Service Type and Service Rate for each connection profile The Service Rate is the number of cells per second The Service Type can be either Unspecified or Constant Specifying Constant means that the traffic will transmit at a pre defined constant bit rate The default Service Type is Unspecified and the default Service Rate is 0 With this default transmission will be based on a best effort method For example you can set up a connection profile where the Service Type is Constant and the Service Rate is 1000 cells per second You can set up a second profile where the Service Type is also Unspecified but the service rate is set to 500 cells per second Depending on the Encaps options you chose ATM or PPP you can specify the Service Type and Service Rate from the Configure gt Ethernet gt Encaps options menu option or the Configure gt Ethernet gt Interface options menu option Note If you are setting up multiple connection profiles and you specify the Service Type as Constant for each profile make sure the total Service Rate for the profiles
49. thernet adapter in your computer To connect the CellPipe to an Ethernet hub use your own straight through Ethernet cable Connect the blue WAN cable to the port labeled WAN on the CellPipe and plug the other end into the wall jack Illustration DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL Cell 50A or DSL Cell 20A cables continued Description Illustration 3 Connect the power cable to the CellPipe and plug the other end into a wall outlet Connect to the wall outlet last There is no power switch Connecting the power cable turns on the CellPipe 4 To configure the CellPipe connect a serial cable from the CellPipe to your computer You can use the adapter that is provided You must provide your own serial cable After connecting the cables go to page 1 22 to check light activity DSLPipe CellPipe Quick Setup 1 11 Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL HST or DSL HS cables Description Illustration 1 Connect the yellow straight through Ethernet cable to one of the Ethernet ports on the DSLPipe and plug the other end to an Ethernet hub Only one straight through cable is provided with this unit 2 Connect the blue WAN cable to the port labeled WAN on the DSLPipe and plug the other end into the wall jack 1 12 DSLPipe CellPipe Quick Setu
50. ting the power cable turns on the DSLPipe 4 Optional To change the DSLPipe default configuration connect a serial cable from the DSLPipe to your computer You can use the adapter that is provided You must provide your own serial cable After connecting the cables go to page 1 22 to check DSLPipe light activity DSLPipe CellPipe Quick Setup 1 15 Installing the unit DSLPipe CellPipe Quick Setup Connecting the DSL Cell 50S or the DSL S cables Description Illustration 1 Connect the yellow crossover Ethernet cable from the port labeled 10BT on the DSLPipe CellPipe to the Ethernet adapter in your computer To connect the DSLPipe CellPipe to an Ethernet hub use your own straight through Ethernet cable 2 Connect the blue WAN cable to the port labeled WAN on the DSLPipe CellPipe and plug the other end into the wall jack 1 16 DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Connecting the DSL Cell 50S or the DSL S cables continued Description 3 Connect the power cable to the DSLPipe CellPipe and plug the other end into a wall outlet Connect to the wall outlet last There is no power switch Connecting the power cable turns on the DSLPipe CellPipe 4 Toconfigure the DSLPipe CellPipe connect a serial cable from the DSLPipe CellPipe to your computer You can use the adapter that is provided You m
51. turns on and remains on e The wan light is on initially blinks until a connection is established and then remains on e The lnk light is on if there is an ethernet connection e The con light is on initially and then turns off Pwr act Ink W in IT con ON only during the DSLPipe self test If it stays on for more than three minutes contact Ascend Customer service wan ON when there is an active and connected WAN BLINKS when you are not connected to a WAN Ink ON when there is an ethernet connection established If it is not on check to make sure your ethernet cable is properly connected act BLINKS when there is any LAN traffic Otherwise it remains off pwr ON when the DSLPipe has power If it is not on make sure the power supply is properly connected 1 22 DSLPipe CellPipe Quick Setup Getting ready to configure 2 Getting ready to configure the DSLPipe or CellPipe unt 2 1 The DSLPipe CellPipe main window 0 0 cece cee eee eens 2 3 Navigating within the DSLPipe CellPipe window 2 4 Most of the DSLPipe CellPipe units share the same user interface window and are configured in a similar way The DSL Cell 20A and the DSL HSTB units however are bridging only units and allow for very limited software configuration These two units display a different command line interface To view or change the configuration for these two units see Configurin
52. u will be using a VC connection with IP rout ing Note The to the left of a field indicates that it is a required field You must fill in a value for the field Configure gt Chan Usage Leased Unused My Name My Addr 204 215 204 215 Rem Name ex2 Rem Addr 10 10 10 10 Encaps ATM Mux Type ATM VC Vpi 1 Vci 10 Route IP Bridge No Send Auth N A Send PW N A Recv Auth N A Recv PW N A Rate Mode singlebaud SDSL Line Rate 528000 Unit Type CPE 3 30 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3 11 Configuring the DSLPipe 50S as CPE Scenario DSL Cell 50S configuration 3 Assume you are setting up ATM Configure gt over SDSL with VPI 5 VCI 20 Chan Usage The data rate is set to 144 Kbps and Leased Unused you are using the unit as CPE My Name Assume you will be using a LLC My Addr connection with bridging Also Rem Name ex3 assume that you want to specify a Rem Addr constant rate of 1000 cells second Encaps ATM Mux Type ATM LLC Vpi 5 Note The to the left of a field ANCA SH indicates that it is a required field Route None You must fill in a value for the field Bridge Yes Send Auth N A Send PW N A Recv Auth N A Recv PW N A Rate Mode singlebaud SDSL Line Rate 144000 Unit Type CPE continued on the n
53. u will be using a LLC connection with IP routing Assume you are using PAP authentication with password lala Configure gt Chan Usage Leased Unused My Addr 204 215 204 215 Encaps PPP Mux Type ATM LLC Vpi 5 Vci 20 Configure gt Ethernet gt Connections gt Station ex1 Active Yes Encaps PPP Dial N A Route IP Yes Bridge No Dial brdcast No Encaps options Send Auth PAP Send PW lala Interface Type AALS Ip options LAN Adrs 10 10 10 10 Telco options Call Type Nailed Group 1 Interface options MUX Type ATM LLC vpi 5 vei 20 Service Type Unspecified Service Rate 0 DSLPipe CellPipe Quick Setup 3 27 Configuring the unit DSLPipe CellPipe Quick Setup Table 3 10 Confiuging the CellPipe 50A as CPE Example Scenarios CellPipe Configuration 4 Assume you are setting up on demand PPP over ATM with VPI 5 VCI 20 Assume you will be using a LLC connection with IP routing Assume you are using PAP authentication with password lala Configure gt Chan Usage Switch Unused My Addr 204 215 204 215 Encaps PPP Mux Type ATM LLC Vpi 5 Vci 20 Configure gt Ethernet gt Connections gt Station ex1 Active Yes Encaps PPP Dial N A Route IP Yes Bridge No Dial brdcast No Encaps options Send Auth PAP Send PW lala Interface Type AALS Ip options LAN Adrs 10 10 10 10 Telco o
54. ust provide your own serial cable After connecting the cables go to page 1 22 to check light activity Illustration DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Connecting DSL 2S cables Description Illustration 1 Connect the yellow crossover Ethernet cable from the port labeled 1 0BT on the DSLPipe to the Ethernet adapter in your computer To connect the DSLPipe to an Ethernet hub use your own straight through Ethernet cable 2 Connect the WAN cables from the DSLPipe to wall jacks Only one WAN cable blue is supplied If your jack supports two lines you can use a single cable for both connections Connect from the port labeled WAN 1 2 to the jack DSLPipe CellPipe Quick Setup Installing the unit DSLPipe CellPipe Quick Setup Description 3 Connect the power cable to the DSLPipe and plug the other end into a wall outlet Connect to the wall outlet last There is no power switch Connecting the power cable turns on the DSLPipe Optional To change the DSLPipe default configuration connect a serial cable from the DSLPipe to your computer You can use the adapter that is provided You must provide your own serial cable Connecting DSL 2S cables continued Illustration After connecting the cables go to page 1 22 to check light activity DSLPipe CellPipe Quick Setup Ins
55. wet locations e Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface e Use caution when installing or modifying telephone lines e Avoid using equipment connected to telephone lines other than a cordless telephone during an electrical storm There is a remote risk of electric shock from lightning e Do not use a telephone or other equipment connected to telephone lines to report a gas leak in the vicinity of the leak A Warning To reduce the risk of fire communication cable conductors must be 26 AWG 0 13 mm or larger Avertissement Afin de r duire les risques d incendie les fils conducteurs du cable A de communication doivent tre d un calibre minimum de 26 AWG American Wire Gauge c est dire d un minimum de 0 13 mm Warnung Um Feuer Risiko zu reduzieren m sssen die Querschnitte der Kom A munikationskabel Leiter 0 13 mm oder gr er sein B SPECIAL REQUIREMENTS 18 Lithium batteries DSLPipe CellPipe Quick Setup vii Important safety instructions A A 19 Warning The battery can explode if incorrectly replaced Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Avertissement Il y a danger d explosion si la batterie n est pas remplac e correctement Remplacer uniquement avec une batterie du m me type ou
56. wing list displays DLCI 16 Status Active input pkts 293723 output pkts 496500 input octets 223406698 output octets 249929584 Table 3 5 provides a description of each field Table 3 5 Frame Relay DLCI status screen Fields Description DLCI DLCI number of the PVC The default is 16 Status Active or Inactive Active if the Frame Relay connection is down connection is up Inactive if the Frame Relay connection became active input pkts Number of packets received by the unit since the connection became active output pkts Number of packets sent by the unit since the connection became active input octets Number of bytes received by the unit since the DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3 5 Frame Relay DLCI status screen Fields Description output octets Number of bytes sent by the unit since the connection became active Displaying SDSL rate To display the SDSL line rate type the following lucent show sdsl stats The current SDSL rate displays in the screen The default is 2320 Kbps Changing configuration information Using the command line interface of the DSL HSTB you can change the console baud rate the Frame Relay DLCI and the SDSL line rate You can also choose to turn off the SDSL rate Autohunt option Changing the console baud rate The default value at which you connect to the DSL
57. xit at the prompt lucent exit DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Example configurations Since only parameters that you are changing are shown in these examples the display you see on the screen will not match the parameters shown in the examples The values shown are examples Obtain the actual values from the telephone company providing you with DSL access Note The options you choose from the Configure menu only apply to the first connection profile 3 18 DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup DSL HST as CPE Table 3 6 Configuring the DSL HST as CPE Example Scenarios as CPE DSL HST Configuration 1 Assume you are setting up a DSL HST for Frame Relay with only IP routing enabled Note When you set up a DSLPipe for Frame Relay you must create a Connection profile and a Frame Relay profile Configure gt Chan Usage Leased Unused My Name CPE My Addr 204 215 204 215 Rem Name COE Rem Addr 192 168 200 1 24 Route IP Bridge No SDSL Line Rate 784000 Unit Type CPE Ethernet gt Connections gt COE Active Yes Encaps FR Encaps options FR Prof frame relay DLCI 16 Ethernet gt Frame Relay gt COE Name frame relay Active Yes FR Type DTE Link Mgmt T1 617D DSLPipe CellPipe Quick Setup Configuring the unit DSLPipe CellPipe Quick Setup Table 3