        MP TR_Instruction Manual_V6_061615.indd
         Contents
1.         Needle support Depth adjustment dial LED control     Green  Working      Flashing red  Empty battery    Red and green  Charging        Battery charge connector        gt    gt  A    On Off Power Button       2 MicroPen TR      Rev  02 of 6 16 2015    3  SETTINGS    Assemble the MicroPen TR    as follows     1  Attach the needle connector       2  Connect the tube to the needle connector    Screw the short drip tube  connector into the needle  connector        3  Connect the needle to the MicroPen TR       Connect the tube to  the output port     Insert the needle  inside the needle  support  The needle  must be pushed up  and fully seated into  the nose assembly        MicroPenTR      Rev  02 of 6 16 2015 3    4  Connect the suction needle to a tube     Screw the tube to the  suction needle        5  Connect the suction needle to the vial    Remove the cap and  pierce the vial membrane  with the suction needle     NOTE  A lowing some  air into the vial may be  necessary to obtain a  regular flow of product  to the needle        6  Set up the METR vial    Insert the vial in the  upper housing chamber  of MicroPen TR        Connect the tube to the  Input Port        4 MicroPenTR      Rev  02 of 6 16 2015    3  1 SET UP    To prepare the MicroPen TR for use  connect a 3 cc syringe with saline  solution to the female to female connector and attach to the Input Port   Press the Power Button  Once the unit is on  press the Power Button and  hold for 3 seconds in order to pr
2.    Rev  02 of 6 16 2015    MicroPen TR    and the battery are guaranteed for one  1  year from the  date of purchase     The MicroPen TR    components and its battery are subject to strict  environmental rules and should be disposed of according to local  state   federal and country regulations     8   CAUTIONS  amp  WARNINGS    THE OPERATION OF MICROPEN TR    IS STRICTLY LIMITED TO HEALTH  CARE PROFESSIONALS WHO HAVE RECEIVED SPECIFIC TRAINING   IN THE USE OF THE DEVICE AND HAVE BEEN CERTIFIED BY THE  COMPANY OR ITS REPRESENTATIVE     All users must know and understand the risks and contraindications  associated with MicroPen TR applications and treatments  The METR  fluid product used with the MicroPen TR must not come in contact  with the eyes  the mouth or mucous membranes  In case of accidental  contact  rinse well with water     ONLY THE METR FLUID PRODUCT SUPPLIED BY THE MANUFACTURER  OF THE MICROPEN TR CAN BE USED BY THE HEALTH CARE  PROFESSIONAL SUPERVISING THE TREATMENT     Failure to adhere to this warning  absolves the manufacturer of any and  all liability     The practitioner must acknowledge the possibility of a negative ora  partial result     Risks of poor healing  hvperpigmentation  hypopigmentation or allergies  to the technique can occur  Please review the supplied documentation  covering Risks and Contraindications to treatment     9   CONTRAINDICATIONS    The METR treatment is contraindicated for the following conditions     Pregnant or breast feeding   
3.   Patients who have demonstrated allergy to hydroxypropanoic acid    Patients who have demonstrated healing difficulties     Patients with suppressed immune response     Patients with hemophilia    It is necessary to exercise caution for the following patients      Diabetic patients     Patients with poor healing capacity     Patients undergoing long term steroid treatment     Patients immunocompromised either through drug or disease    MicroPen TR      Rev  02 of 6 16 2015 9    10   GENERAL FEATURES  10 1 IDENTIFICATION    Model  TRIOOO      Manufactured for  Owner of the homologation   Eclipse Aesthetics  LLC  BFP Electronique  13988 Diplomat Drive  Suite 160 Pole Technnologique de Vimenet  Dallas  Texas 75234 48100 MONTRODAT   France  800 759 6876  33  034 66 32 44 99      Manufacturer of the device  Idem  10 2 GENERAL CONFIGURATION    Model reference  MicroPen TR    Tattoo Removal      Serial number  MG amm 0000    11   TECHNICAL CHARACTERISTICS    Dimensions   23 x 10 x 3 cm  Weight  170 g   Voltage  5 V     Protection  IP 20   Power  8 W   Battery    Type  Li lon   Capacity  0 80 Ah  Autonomy  2 hours  Charging time  1 hour  Charge voltage  5 V    Electric security  A  type B     BH WARNING  Refer to instruction manual    Y Identification of waste electrical and electronic equipment   WEEE  according En    CE    0459    
4.  from the  left to the right     w  DEEP    we DEEP         C    VISUAL CONTROL OF THE DEPTH SETTING IS IMPORTANT  BEFORE ANY TREATMENT    5   IMPORTANT INFORMATION FOR PATIENTS    Removing tattoos is a definitive visual modification of the body  It is  important to explain to the patient all aspects of the treatment phase  and the aftercare regimen required to ensure a successful result     The Patient Consent Form document should be reviewed by the patient  and signed  See Patient Consent Form documents     ONLY ADULT PATIENTS WHO ARE OVER 18 YEARS OF AGE ARE  ELIGIBLE FOR TREATMENT  PARENT OR GUARDIAN CONSENT IS  REQUIRED FOR UNDER AGE PATIENTS     5 1   Preparation of the Patient before treatment   Treatment with MicroPen TR    should be preceded by a review of the  patient care instructions and compliance rules for a successful outcome   Use the Patient Consent Form supplied with pen to ensure the patient is  adequately informed about risks and benefits     MicroPen TR      Rev  02 of 6 16 2015 7    6   CHARGING THE BATTERY    The MicroPen TR    is equipped with an internal Lithium lon battery which  has a life of 2 hours treatment time     The battery level is indicated by the light indicator on the device     Full battery  Green light     Empty battery  Red flashing light     Charging  Green and red light simultaneous    When a red flashing light appears  the battery should be recharged by  plugging the pen into the power supply       Charging time is approximately abo
5. ECLIPSE i  MICROPEN 72    TATTOO REMOVAL    USER MANUAL       Dont reget al    kKemove itt    METR  Mechanized Epidermal Tattoo Removal    aN  ECLIPSE  AESTHETICS S    TABLE OF CONTENTS PAGE    lt UNPACKING COUR MICROPREN TR estaa E E N    AA A e e A E E 1  PE a E OP PEO see E EA O A einen E 2  NN E AAA eb nua A E E EN AET     SS A e A SEE EE er A E AE E tere 5  As UG THE IVICA Ce IN Dart ii 6  AT AOI SWING  THE SPEED OF  THE MOTOR sun 6  A AUJIUSTING THE NJEG HON DER f trcranieasoininiaasenadtenpiniaavemantonniotiesaeed ei 6  5A IMPORTANT INFORMATION FOR PATIENTS escindida 7  S14  PREPARATION OF THE PATENI BEFORE TREAILMENTE sssavosneri   7  Se SUG  TAE BATTERY kerensa O OU EAEEREN 8  Te IAS UE AN SE ai cee io aci 3  Sr TON MARINO raices oa iobn d  ICINTRAINDICA TIKAN O eenean crt Mn EREA NaS EE EEEE Ae aAA REEERE SEEE 9  1U GENERAL FEATURE Spore E E ENBE EVEEN REE 10  CADENAS NN tata idas 10  10 2 GENERAL CONFIGURATION sekinten nanesen eniak k eiir 10    L TECANICAL CP TD Sutil rss 10    1  Unpacking Your Eclipse MicroPen TR       Thank you for choosing the Eclipse MicroPen TR     Please check  the case contents as follows  Make sure that your case includes     Protocols  information and  registration of the patient    1 USB key                 MESE  TA ICROPEN TR     00 REMOVAL    USER MANUAL       r   S 3 needle   s    1 MicroPen TR    device   Se OET    sandal  j A  1 MicroPen TR    support  2 cleaning liquids    a    i b        1 power supply  DE    4 z  i 3 needles tre
6. atment        N 3 needles 50 mm of    suction product    1 METR vials 6 tubes 130 mm    1 Female to Female Luer Lok      INTRODUCTION    The Mechanized Epidermal Tattoo Removal  METR  technique is a modern  version of an old technique used to remove tattoos  The technique is based  on the theory of localized partial healing  Its advance over original methods  is to rely upon small surface area  closely spaced partial thickness injuries  with intervening skin bridges to return the tattooed area to normal skin  color  The use of closely soaced needles  similar to those used in traditional  tattoo devices  is necessary to obtain defined penetration depths  The  needles facilitate penetration of the tattoo target to a defined depth where  the special Tattoo Removal MicroPen TR    fluid is introduced     The tattooed area will reject the ink through cutaneous exfoliation and    produce a scab or eschar  The treated area will heal over a period of 2 to  3 weeks and the scab will fall away leaving clear skin beneath     MicroPen TR      Rev  02 of 6 16 2015 1    Repeat treatments are scheduled to treat the remaining pigmented  areas  This technique allows the whole area of the tattoo to be  progressively and sequentially covered  and then removed  in three   five  sessions  See Treatment Information Form for full detail     2  DESCRIPTION    Suction needle       Short drip           Output Port          Trigger button    Long touch  boot    Short touch  starting for 12 seconds      
7. ime the system and purge any excess  air  The system will run the prime cycle for approximately 2 minutes   During the beginning of the prime cycle  apply extremely light pressure  to  but do not push  the syringe   s plunger  Hold the pen in a vertical  position during the process  Once you see droplets exiting the system  from the Output Port  you will know the system has been primed and is  free of excess air  Allow the two minutes process to finish     Trigger Button       NOTE   f you do not see droplets exiting from the Output Port  you may  need to repeat the prime cycle to ensure all air has been removed  THE   OPERATOR SHOULD VISUALLY CONTROL THE AMOUNT OF FLUID IN  THE NEEDLE RESERVOIR    MicroPen TR      Rev  02 of 6 16 2015 5    4   USING THE MICROPEN TR       4 1 ADJUSTING THE DEPTH  In order to treat different kind of tattoos and skin types  the depth  of the MicroPen TR    is adjustable  To adjust the depth  power on the  MicroPen TR  Tap the center of the Trigger Button to turn on the  needle motor  which will last for 12 seconds  During that time  turn  the depth adjustment dial to the left or right to find the ideal setting           Depth adjustment dial    Progressively INCREASE depth by rotating one full rotation from  left to the right using the black measurement mark as your guide   Progressively DECREASE by rotating one full rotation from right to  the left     6 MicroPen TR      Rev  02 of 6 16 2015    Rotation from the  right to the left     Rotation
8. ut 1 hour   NOTE  MicroPen TR    may be used while the battery is charging     7   MAINTENANCE    If MicroPen TR    is not used daily  the system should be    bled    to remove  old treatment fluid     Connect a 3 cc syringe with saline solution to the female to female  connector and attach to the Input Port  Press the Power Button  Once   the unit is on  press the Power Button and hold for 3 seconds in order to  remove any old fluid from the MicroPen TR  The system will run the priime  cycle for approximately 2 minutes  During the beginning of the prime  cycle  apply light pressure to  but do not press  the syringe plunger  Allow  the cycle to complete     Regularly clean the device with a soft  lint free wipe or cloth  Do not use  proprietary cleaning solution on any component of MicroPen TR        Parts that come into contact with a patient must be changed between  each patient or sterilized according to the manufacturer   s instructions     SINGLE USE PARTS  MICROPEN TR    NEEDLE   SHORT DRIP   SUCTION  NEEDLE         METR VIAL MUST BE CHANGED BETWEEN EACH PATIENT     REUSABLE PARTS  NEEDLE CONNECTOR MUST BE REPLACED OR  DECONTAMINATED IN A COLD SOLUTION OF 2  GLUTARALDEHYDE  BEFORE EACH USE        Please check individual state  local  federal and country regulations for correct  care and sanitation of each component used in the MicroPen TR    process     To extend the life of the MicroPen TR    system  an ANNUAL FACTORY  tune up is highly recommended     8 MicroPen TR   
    