Home
Neutron 4 user manual
Contents
1. network operator or changes in mobile network itself For devices which are broken during warranty time ionSign Oy delivers a new device for free Alternatively device can be corrected Broken device should be returned to supplier if required The cost of delivery is paid by supplier ionSign Oy is not responsible for indirect or implicit damage or possible work or travel expenses related to broken device For warranty issues please contact to ionSign Oy by e mail ionsign ionsign fi or by tel 358 0 2 822 0097 Copyright 2013 ionSign www ionsign fi v1 3
2. User manual IOnNSIGN 26 9 2013 Neutron 4 Neutron 4 1 General Neutron 4 is a general purpose pulse counter designed for collecting and reporting pulses from different kind of energy and consumption meters Pulses are collected on an hourly basis and sent to server once per day 2 Introduction The device will be introduced as follows 1 Disable PIN query from the SIM card for example with cell phone 2 Open enclosure and insert the SIM card to the device 3 Connect power supply measuring device or devices and GSM antenna to the device See picture 1 STATUS GSM Ant Picture 1 Device front panel 4 Set power on which STATUS LED indicates by fast blinking 5 Device starts to search GSM network and GSM LED start to blink fast When network connection is established GSM LED blinks slowly and STATUS LED is solid lf STATUS LED continues blinking after network connection is established then signal is weak In this case GSM antenna should be placed better 6 Send SETTINGS command to the device After that the device starts to operate Received command is indicated by STATUS LED which is turned off Connection to server is indicated by solid green STATUS LED If STATUS LED is not turning to green then SETTINGS command validity should be verified Copyright 2013 ionSign www ionsign fi v1 3 User manual 1OnSIGN 26 9 2013 Neutron 4 3 The functionality of device LEDs Multicoloured STATUS LED Soli
3. cation waits for transmissions APN parameter is determined APN Access Point Name of GPRS connection Maximum length is 19 characters Input count parameter is determined the number of connected meters in device Range is 1 4 Transmission delay parameter is determined delay from midnight This avoids unique devices to send pulse data to server at the same time Range is 0 1000 minutes With parameter value O the data is sent at midnight 00 00 Server path parameter is determined path in server where data is saved Example command where device identifier is 101 server address is services ionsign fi server port is 80 APN is internet input count 4 transmission delay is 1 minute and server path is neutrondata SETTINGS 101 services ionsign fi 80 internet 4 1 neutrondata INTERVAL lt ime gt With this command the device is set to send pulse data to server with defined interval Server is defined with settings command Time parameter is determined time which triggers the data sending to server Range is 0 or 60 65535 seconds With parameter value 0 the data sending by interval is stopped SENDNOW With this command the device sends incomplete pulse data to the server immediately This command has no parameters FACTORY With this command the device resets all its settings and pulse data This command has no parameters Copyright 2013 ionSign www ionsign fi v1 3 User manual 1onsicn 26 9 2013 Neutron 4 5 Neutro
4. d red The device has no settings Give valid settings with SETTINGS command by text message Solid green The device has valid settings and connection to server is established Turned off The device has settings but connection to server is not established Check that the command is given correctly and give SETTINGS command again if necessary Blinking green or red The device has a weak GSM signal or it s not in the GSM network Orange blink The device has received one pulse from input Red colour GSM LED Blinks fast The device is searching GSM network Blinks slowly The device is in GSM network Copyright 2013 ionSign www ionsign fi v1 3 User manual 1OnSIGN 26 9 2013 Neutron 4 4 Commands The device is controlled with text message commands shown below The device does not send any reply messages Commands and parameters are separated by one space character SETTINGS lt Device identifier gt _ lt Server address gt _ lt Server port gt _ lt APN gt _ lt nput count gt _ lt Transmission delay gt _ lt Server path gt With this command all required settings are given and pulse data counting is started Device identifier parameter is determined unique ID for each device Range is 1 32765 Server address parameter is determined IP address of the http server Alternatively a domain name server name can be used Maximum length is 30 characters Server port parameter is determined port number where server appli
5. n 4 specifications e Inputs 4 pulse inputs for open collector or relay outputs of meters Open collector or relay output sourcing voltage 12 VDC maximum sourcing current 5mA Operating voltage 11 13 VDC 2 5mm DC socket Current consumption 70 mA peak 250 mA Real time clock 4 days backup Size WxHxD 125 x 51 x 25 mm Flanged ABS plastic enclosure Protection class IP20 Operating temperature 25 C 50 C RH 5 95 non condensing Data storage capacity 30 days for each hour for each input channels Data communication Integrated GSM GPRS module Conforming the following directives and standards R amp TTE Directive 1999 5 EC Radio Equipment amp Telecommunications terminal Equipments Low Voltage Directive 73 23 EEC and product safety Directive 89 336 EEC for conformity for EMC GSM Radio Spectrum Standard EN 301 511 and 3GPP 51 010 1 EMC Electromagnetic Compatibility Standards EN 301 489 1 and EN 301 489 7 LVD Low Voltage Directive Standards EN 60 950 e Antenna External SMA connector 6 Warranty ionSign Oy agrees the warranty of two 2 years for Neutron devices Warranty starts from the day when the customer has received the device and it concerns material and production defects Warranty is not agreed for devices which are used or wired incorrectly It is not also agreed for situations where defect is related to 3rd party actions Things like this can be service changes by mobile
Download Pdf Manuals
Related Search
Related Contents
LG Electronics 235C Cell Phone User Manual Videojuego 3D para Celulares con J2ME, M3G y Bluetooth 制御棒の想定外の引き抜け事象に関する報告について ROUTE 66 Navigate 7 User Manual Sony VAIO VPCY216GX English 8396 Samsung Q97 - Chantry Digital Ltd 商品特長 一品削り出し本丸釜 かまど銀釜 倍増釜底WAVE 高火力炊飯 maestro 18 / 36 sws User Manual Copyright © All rights reserved.