Home
Honeywell DR4300 Users manual, 44-01-25-16a
Contents
1. Figure 2 7 Models without CE Mark or 2 8 Models with CE Mark in the Product Manual for your specific model type e Run power wires separately through conduit holes as indicated in Figure 2 5 or 2 6 in the Product Manual e Strip 1 4 inch maximum of insulation from the end of each wire and form end to fit under a screw connection e Install the power wires into the correct screw terminals as shown in Figure 2 7 or 2 8 in the Product Manual to avoid damaging the recorder e Refer to document 51 52 05 01 for additional information concerning Line Voltage Input noise interference prevention 11 99 DR4300 Circular Chart Recorder Quick Start Guide 44 01 25 16A Instument Configuration sw1 or recorder models WITHOUT display and keypad Configuration switches SW1 and input switches SW6 are provided on each pen channel s printed circuit assembly SW6 e Go to Table 3 2 in the Product Manual and find the desired combination of recorder selections and input type for the pen 1 channel e Set the switches in SW1 and SW6 as indicated in Table 3 2 of the Product Manual for pen 1 on the printed circuit assembly on the right side of the recorder Pen 1 is purple e Repeat for pen 2 on its printed circuit assembly located on the left side of the recorder if available For recorder models WITH display and keypad Input switches SW6 are provided on each pen channel s printed circuit assembly e Go to Table 4 3 i
2. Honeywell Getting Started with DR4300 Overview The DR4300 recorder is a one or two pen microprocessor based circular chart recorder providing reliable convenient pen drawn analog traces on preprinted 10 inch charts Chart speed and range are configurable In addition to generating pen drawn chart traces the DR4311 and DR4312 models include a display and keypad This option lets you display the real time value of the process variable for each pen channel as well as other values Each pen channel has its own printed circuit assembly allowing the channels to operate independently Connecting the Analog Inputs e Open the recorder door Loosen the captive screw in the chart plate and swing the plate out e Locate terminal block TB2 on the right edge of the printed circuit assembly for pen 1 right side of the recorder e Insert the wires under the appropriate screws for the applicable input type Refer to Figure 2 9 in the Product Manual for specific input actuation wiring e Tighten the screws to secure the wires e f the recorder has two pens repeat these steps for the second channel to TB2 on the pen 2 printed circuit assembly located on the left side of the recorder Separate recorder models are available for use with 100 Vac to 240 Vac or 20 Vdc to 27 Vdc power Refer to model number information in Section 1 Overview of the Product Manual e Locate the power terminal block for your recorder model Refer to
3. he chart time line Turn on the power to the instrument and it will start recording your input For information on connecting the other input and output options refer to Section 2 in the Product Manual Technical Assistance If you encounter a problem with your DR4300 recorder you can receive technical assistance by dialing 1 800 423 9883 USA and Canada An engineer will discuss the problem with you Please have your complete model number serial number and software version available 44 01 25 16A DR4300 Circular Chart Recorder Quick Start Guide 11 99
4. n the Product Manual and find the desired input type for the pen 1 channel e Set the switches in SW6 as indicated in Table 4 3 of the Product Manual for pen 1 on the printed circuit assembly on the right side of the recorder Pen 1 is purple SW6 e Repeat for pen 2 on its printed circuit assembly located on the left side of the recorder if available e Go to Table 4 4 in the Product Manual for the configuration procedure Refer to Figure 4 2 in the Product Manual for a sequenced prompt hierarchy and to Tables 4 5 through 4 78 for configuration parameter definitions Upper Display four characters e Normal operation Displays process variable PV for the selected input channel e Configuration mode Displays selection or parameter value Indicates temperature Data displayed units of PV on display is for input Channel 1 or 2 Output relay 1 or 2 is ON when lit Indicates controller mode M Manual A Automatic When either of the remote switch is set for SP2 or when NumSPs TWO L Setpoint 1 SP active R Setpoint 2 S2 active Otherwise neither indicator is used Lower Display six characters e Normal operation Displays selectable operating parameter label and value With totalization shows totalizer value e Configuration mode Displays Set Up group and function parameters Ready to Start Up Refer to Table 3 5 or 4 22 in the Product Manual for procedure to set t
Download Pdf Manuals
Related Search
Related Contents
Anleitung für e-Bikes 2013 Franke 700 FHM 705 4G TC XL E Emerson (K490) Diagrams and Drawings Futaba 6XA 6XH - Piper CUB hobby Plantronics BackBeat™ 903/906 Copyright © All rights reserved.
Failed to retrieve file