Home

User Quick Guide - thetechgods.net

image

Contents

1. enhance store send and print images use the CliniView imaging software or another imaging application through the Instrumentarium TWAIN driver Before using the sensor read the VVarnings and Precautions in this guide Read the following manuals to familiarize yourself with the operation of the unit before installing and using it Snapshot Installation amp User Manual CliniView Installation Manual CliniView User Manual and Instrumentarium TWAIN Installation amp User Manual PACKAGE CONTENT 1 Snapshot intraoral sensor 2 Imaging application CD CliniView or CliniView XV in the USA includes software and manuals 3 Snapshot CD TWAIN driver Snapshot manuals A User Quick Guide 5 Sensor cable clip fo attach the Snapshot e g to a lead apron 6 Wall mount set to store the Snapshot when it is not in use 7 CMOS sensor 8 Indicator Light Orange Standby Green Ready for image capture Blinking Image transfer ltem number 203255 rev 5 Document number D503052 rev 5 21 4 2009 INSTRUMENTARIUM INSTALLATION 1 Insert the CliniView CD into the CD ROM drive The installation program starts Follow the on screen instructions to install the CliniView Software _ Restart the computer Connect the sensor to the USB port of the computer Start the Cliniview program select a test patient and start the image capture _ CliniView installs the sensor gainfiles automatically The installation is comple
2. Gp INSTRUMENTARIUM symecols Attention consult accompanying documents Contains warnings and instruc tions about the safety of the unit If these warnings are not observed serious risks and injury may be caused to the patient and operator C CE marked according to the Medical Device Directive 937 42 7 TEC 0537 7 4 USB connection Type BF equipment IP44 The degree of protection provided by the Snapshot unit Protected against solid objects over 1mm tools wires amp small wires Protected against water sprayed trom all directions limited ingress permitted The degree of protection provided by the sensor 7 g p p y Totally protected against dust Protected against the effects of immersion be tween 15 cmand Im Mus WITS GK Revised May 30 2003 3174420 not be disposed as unsorted municipal waste and must be collected separately Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment et This symbol indicates that the waste of electrical and electronic equipment must Instrumentarium Dental Nahkelantie 160 P O Box 20 04300 Tuusula Finland fel 358 10 270 2000 CE fax 358 9 851 4048 0537 User Quick Guide Snapshot Intraoral Sensor System by Instrumentarium Dental NTRODUCTION The Snapshot digital intraoral sensor is designed to produce high qual ity digital X ray images of teeth and adjacent structures To view
3. st not be brought in to the patient environment Personal computer should only be connected to grounded outlet Inspect periodically the sensors Do not sterilize the sen sor using autoclave or UV oven Make sure that the Ready LED illuminates before making an exposure Recommended exposure values are in the user manual Any service attempts by unauthorised persons are strictly prohibited Use a fresh disposable hygienic cover for every patient Operating tempera ture range is in the user manual Find the electromagnetic compatibility tables according to IEC 6060 1 1 2 Ed 2 in this Instrumentarium Dental Snapshot user manual USA only Federal law restricts this device to sale by or on the order ot a dentist or other qualified professional ltem number 203255 rev 5 Document number D503052 rev 5 21 4 2009
4. te when the indicator light on the sensor is green 8 Take a test exposure Cn A Go NO SOs USING THE SNAPSHOT SENSOR Positioning and Exposure 1 Protect the sensor with a hygienic cover Use a sensor holder 2 Start image capturing from the sottware see next two chapters below 3 Place the sensor into patient s mouth A Position the X ray tube head and make an exposure See Tips and Hints in Snapshot Installation amp User Manual in the Snapshot CD Capturing Image with the Cliniview Software Single image 1 Start the CliniView software and select the patient 2 Press the Start intraoral image capturing button 3 Position the sensor Select the exposure values and press the exposure button 4 Stop image capturing and save the image Use template to take several images of the same patient by pressing the template button Images can be adjusted with a variety of image adjustment tools See CliniView manual tor details MAINTENANCE AND SERVICE Service There are no user serviceable parts Cleaning Use a cloth moistened in mild cleaning solution soap or mild disintectant to clean the Snapshot unit Disintecting the sensor Only the CMOS sensor can be immersed in disinfectant solution e g Virkon Cidex Follow the disinfectant instructions carefully Do not use aggressive chemicals Do not immerse the Snapshot unit O WARNINGS AND PRECAUTIONS If a IEC 60950 compliant non medical PC is used it mu

Download Pdf Manuals

image

Related Search

Related Contents

barandillas laterales para cama ad 952  5996 Manual SlurrySlang.indd  の策定について  Kenwood KDC-HD548U Car CD/MP3 Player - 200 W RMS - iPod/iPhone Compatible -  取扱説明書 - デイトナ    Bedienungsanleitung_Panasonic_DMR-HCT130_D  Pediatrie--lettre de nourrisson à ses parents  Pompa a siringa Alaris® TIVA    

Copyright © All rights reserved.
Failed to retrieve file