Home

User manual Rev A

image

Contents

1. Parity Even Connect the Wiegand wires example as below The pull high resister must gt 10K Ohm Optional Red Data 1 White External L ED Buzzer Control HOST Terminal Pull high resistor gt 10K Ohm Brown PROMAG DESFire REV A ANNEX C ABA TK2 Interface The timing for Card Present Clock Strobe and Data example as below CARD PRESENT Leading Zero Data i Trailing Zero DATA gt STROBE Width Approximately 25 50 Of Bit Time gt Bit Time 40IPS min 280us typ 330us max 480us DATA The data signal is valid while the clock is low If the Data signal is high the bit is a zero If the Data signal is low the bit is a one CLOCK STROBE The Clock signal indicates when Data is valid It is recommended that Data be loaded by the user with the leading edge negative of the Strobe CARD PRESENT Card Present will go low after flux reversals fromthe Reader Card Present will return high after the last flux reversal Connect the ABA TK2 wires example as below HOST Terminal Card Present Orange Clock White Data Green mz ED Buzzer Control Brown Optional External LI 20 PROMAG DESFire REV A ANNEX D RS232 Interface Connect the RS232 wires example as below HOST Terminal TXD Yellow GND Black ED Buzzer Control Brown External LI Opt
2. E Mifare DESFire Reader Utility 1 1R9 Settings Wiegand C ABATK2 C RS232 Cara Data ony F Output Mode Card Data Only a Card Data or CSN When card error Once CSN Only Continue Reader Auto Scan Update Reader Test TEKE Language DF700 Reader On COM1 Reader ID Default 0 DESFIRE Reader ID for multi link application ID 0 99 Interface Default Wiegand DESFIRE READER can be set as Wiegand RS232 or ABA TK2 output Read Mode Default Card Data Only a Card Data Only Read card sector data only If any error ex mifare key error reader will show Card Invalid status Card Data or CSN Card Serial Number Read card sector data If any error ex mifare key error reader will send the CSN to host CSN Only CSN read only Output Mode Default Once a b Once Send data or CSN to host once Continue Keeping sending data or CSN to host till card remove PROMAG 4 LED Buzzer Settings Mifare DESFire Reader Utility 1 1R10 m LED Buzzer Settings Enable RS232 Command Set Control Enable Two Wires Control LED Disable ABA TK2 EMEK cen Brown Wire PULSE Internal Card Valid Vv Brown Wire Inactive Internal Card Invalid j Green i N LR N Cada Wi Green ERR S Disable SAU After Data Output Any Time DESFire REV A V Red Red 1 Beep Blink sd f V Red 3 Beep Blink V Red 3 Beep Biink High C
3. Include Reader ID is to set the Wiegand output data to include Reader ID when it is enabled Default Disable Custom Premable is to set the Wiegand output data to include premable code when it is enabled This code only combine with CSN output Default Disable Number of Bits is to set the Wiegand output type you want to meet your Host or Terminal It can be 1 to 128 Default 26 Bit Sequence is to set the Wiegand output data sequence it can be standard data sequence MSB first or Reverse data sequence LSB first Default Standard Byte Order is to set the Wiegand output data sequence it can be ISO High byte first or Non ISO Low byte first PROMAG DESFire REV A 6 ABA TK2 Settings E Mifare DESFire Reader Utility 1 1R9 ABA TK2 Settings Number Of Digita fio Add Reader ID MSB First LSB Fit BES fon vvccomm j BIN to DEC Default Decimal String BCD Standard Direct Memory Map Bytes to DEC Reader Auto Scan Update Reader Test ae Language DF700 Reader On COM1 Number Of Digital Set number of digital codes for TK2 output Default 10 Add Reader ID Add Reader ID into TK2 data Default Disable Sequence Set the TK2 data sequence Default MSB First Data Conversion Select card data format to convert a BIN to DEC Default card issue by Mifare Card Issuer Utility b Decimal String ex 123456 c BCD d Direct Memory Map e Bytes to DEC
4. PROMAG DESFire REV A 7 RS232 Setting Z2 Mifare DESFire Reader Utility 1 1R10 Micu Enabled DEEE e LSB MSB LEENE V Header 02h T7 Reader ID I Data Length Output Format Binary Zz 2 Visible Hex Code v CR v LF V Trailer Reader Auto Scan Update Reader Test Vean Language DF700 Reader On COM1 Baudrate can be set 2400bps 57600bps Default 9600bps Data Sequence can be set LSB first and MSB first Default Package is to set the output data packet to include Header Reader ID Data Length CR LF and Trailer Header 00h FFh Trailer OOh FFh Default O2h Visible Hex Code CR LF 03h Output Format can be Binary or Hex String for output format Note 1 Wiegand output data packet with Reader ID Standard Parity Even Reader ID MSB Data Bits LSB Parity Odd Reverse Parity Odd Reader ID LSB Data Bits MSB Parity Even 2 RS232 output data packet with Header Reader ID and Trailer Header Reader ID LSB Data Bytes MSB Trailer 3 ABA TK2 with Reader ID MSB First SS Reader ID MSB Digital Code LSB ES LRC I O BER K S SS Reader ID T SB Digital Code MSB ES LRC Remark DESFIRE READER all configuration items are write only so any users can not read the configuration items from DESFIRE READER to get the App Key that
5. Low a JE TT DF750 Reader On COM1 Enable RS232 Command Set Control For 19200 n 8 1 Only RS232 LED Buzzer command set frame as below STX J NUMBER 0 9 CR 02h 4Ah 30h 39h ODh Command Table NUMBER Descriptions 0 30h All LED Off Buzzer Off 1 31h Green LED ON 2 32h Green LED OFF 3 33h Red LED ON 4 34h Red LED OFF 5 35h Buzzer Beep 1 Time 6 36h Buzzer Beep 3 Time 7 37h Green LED ON with Beep 1 Time 8 38h Red LED ON with Beep 3 Time 9 39h All LED ON Orange Remark If Enable the RS232 Command Set Conirol for LED Buzzer the external LED Buzzer control with high low level control will be disable 11 PROMAG DESFire REV A Enable Two Wires Control LED Disabled ABA TK2 For 19200 n 8 1 Only set up the Brown Wire Active Level and Brown wire and Orange wire will follow the setting Example Brown Wire Active Level High Green light on with a beep when brown wire level high Red light on with three beeps when orange wire level high When both wire change level high at the same time it will both light on without beep Read Idle Show LED color after power on or idle state Brown wire PULSE or Card is valid Show LED color and beeps to indicate the end user when brown wire PULSE or card was passed by DESFIRE Reader Brown
6. Support Non MAD format with user defined sector number 3 Support used card with data offset and length 4 Support Multi Sectors 5 Support Mifare Standard 4K or Mifare Standard 1K card 6 Each Reader with Reader ID for multi link application 7 Output interface Wiegand Default ABA TK2 and RS232 8 Wiegand output selectable from 1 bits to 128 bits 9 RS232 output packet can be set with Header Reader ID and Trailer Application 1 Access Control 2 Time Attendance 3 Guest Registration System 4 Academic Services 5 Info Services PROMAG DESFire REV A Mifare Application Directory MAD Support DESFIRE READER support the MAD format card the MAD mifare application directory standard proposes the introduction of common data structures for card application directory entries DESFIRE Reader should take advantage of this feature using those sector pointers instead of physical sector number The DESFire Reader will search the AID from mifare application directory MAD then got a correct sector number from MAD If the card is not a MAD card the DF700 will use the Non MAD Sector Setting by Mifare Reader Utility About MAD please s the web pages Request Anticollision Card On Reader http www mifare net http www nxp com acrobat_download2 oth er identification 001830 pdf Get Using DF700 Application Sector Non MAD Sector APP KEY Authenticate Read
7. is very important to protect your App Key and all configuration items 15 PROMAG DESFire REV A 8 Configured Card Mifare DESFire Reader Utility Y1 1R10 JV Configured Card Enabled 123FFFFFF123 Reader Auto Scan Update Reader Test Vera Language DF700 Reader On COM1 Configured Card Enabled can allow your reader change configuration by Mifare Card Key is the Mifare Key A for allowed configured card PROMAG DESFire REV A 9 Test DESFIRE Reader after configuration After DESFIRE READER configuration is completed you may use DESFIRE READER Utility Test function to test the DESFIRE READER to see if the configuration is done correctly 1 After the configuration on the DESFIRE READER Utility software is made you should click Update Reader to download the current configuration to the DESFIRE Reader After DESFIRE READER configuration is completed you may click Test to test DESFIRE Reader Get an issued mifare card to put on DESFIRE Reader to be read and see the output data on the window of DESFIRE READER Output Test Wiegand 34 bits output data with standard bit sequence example as below Reader Test egand ABA TK2 Wiegand 26 Standard 0 10000000 11100011 00101111 0 80 E3 2F KE EW a EW Evi el Hej e Vj EE PROMAG DESFire REV A ANNEKX A Hardware Specification DESFIRE READER Major Feature Mifare DESFire Application Directory Reader Acc
8. to update other readers or programmers WebISP Update Information Local Site Comm Port COM1 Device F W PGM TO702 V1 2RO 081014 FTP Site ROM Number PGM TO702 Product RWM600A Version V1 2R0 Update Information October 14 2008 VI 2RO0 Add Tag Sensitive Option Multi Station Supported Improve Invertory amp Refresh Stable Tag Remove Event March 14 2007 vv UEAN PGM To702 RWMEQ0KA a tt st S OSU S Firmware version is latest version cmt LOJN d Kcen ms INC In System Program via Internet Quality Delivery amp Service June 23 2006 Fix Noise to Reset problem June 5 2006 Add stock refresh command Downloading File lt OK GoTo ISP Mode GNetPlus Protocol lt OK Update finished ISP Mode Erase Firmware Programming lt l Update Finish OnLine ftp gigatms com tw UserName Start Check Force C Off Line isp Password Fer 25 PROMAG DESFire REV A ANNEX H Configured Card You can configure the reader by Mifare Card when the Configured Card Enabled is enalbed Step 1 Connect the PCR310 7 Mifare DESFire Reader Utility 1 1R10 to PC for issuing card Configured Card for Click Auto Scan w ya C SF600 Series C SF500 Series LBR700 W Ww Choose DF700 cep Click OK Remark DO NOT connect the reader to PC Step 2 Configure all set
9. wire Inactive or Card Is invalid Show LED color and beeps to indicate the end user when brown wire Inactive or card was failed by DESFIRE Reader Brown wire Active Show LED color and beeps to indicate the end user that brown wire Active signal from Host Brown wire Active level Set Brown wire Active level condition with Host status Disable Always disable the Brown wire Default LED Buzzer control by reader self High Active High Normal keep in Low Low Active Low Normal keep in High Remark If set Active Low you may have to connect brown wire to a pull up resistor 1K 10K with 5VDC Control Brown wire After Data Output The brown wire will be enabling after finished output the card data or CSN Default Any Time The brown wire enabled in any time Note See Annex E the LED Buzzer also can be controlled externally with High Low level control Brightness Change value to brighten or darken led More high and more brighten PROMAG DESFire REV A 5 Wiegand Setting Hifare DESFire Reader Utility 1 1R10 m Wiegand Settings eur Include Reader ID IR Custom Length 0 Custom preamble only combine with CSN output Number Of Bits 26 IT with Parity siecle Standard MSB First C Reverse LSB First EES SO tion Byte Firat Non ISO Low Byte First Reader Auto Scan Update Reader Test ake Language DF700 Reader On COM1
10. A TK2 Card Present Brown LED BUZEER IN External LED BUZZER Control To configure the DESFIRE Reader you need connect the reader to the MF7OOKIT first as below The above housing is for reference only Note MF700KIT is a test connection kit for DESFIRE purchasing YELLOW OR BLUE GREEN READE MF700KIT ANGE CP H GND o D1 w DO RX w TX VCC BROWN R configuration use It is an optional item for PROMAG DESFire REV A Mifare DESFire Reader Utility 1 DESFire Settings Z2 Mifare DESFire Reader Utility 1 1R10 DESFire Card Settings TENTS F47030 TT i Offset Data 0 Length Data File 5 Access Key No fo Access Key Value o0000000000000000000000000000000 Reader Auto Scan Update Reader Test Versi Language DF700 Reader On COM1 MAD AID Default F47030 MAD Application Identifier number is authorized and assigned by Mifare net upon the customer s request for registered Application Identifier in a mifare application open system AID 000000h FFFFFFh Or it is also possible for the user to define the AID himself for the application in user defined closed system without registering into MAD group According to the AID DESFIRE READER can find and read the corresponding app
11. Mifare DESFire Reader User s Manual REV A January 19 2009 PROMAG DESFire REV A Table of Contents Mifare Configurable Sector REAder c ccccscccscssesssseesssecssseesssesssseesseessssessseesssecesseesseeseses 3 Mifare Application Directory MAD Support 0 cccccceccsessssesssseesseessssecsseesssecssseessseseses 4 Mifare User Data Format ic sisiacisicesisieee ee iGo ore aaa 5 WireS Assignmen i ca strona theives ta i arll i Rayan b l le ka kake b Man dud Idee 6 Mifare DESFire Reader Utility L LEE eee kek k k 7 Wigs DESFire Seltlll jS5 i i cun iu ulme inka lal aka kik aid u WENN W VA dew n K OW ek deh k 7 2 Mifare SettinmgSs LL eee keke keyey k y k k k e kk ke k r 8 3 Reader S ttin S i i lt usul a Wene NIN amie i benek b r n ek bir 10 4 LED Buzzer Settings ae eee 11 5 Wiegand Setti0 i iin cin suse esenancotice isuteridovanablananin ienne aeieea a aaao 13 6 ABA TK2 Settings rekak eke keke keke k k k k k ante 14 T R9232 SOTIN 5 453505 54 o0N KR K e K rek WEK ou eles 15 8 Configured Card EL eke keke keke keke keke keke keke keke kek KAKA kK 16 9 Test DESFIRE Reader after configuration ibi 17 ANNEX A Hardware Specificat
12. ROM and make sur they wer DESFire REV A ESFIRE READER also supports the ISP In System Program function to upgrade the in your Windows System first It may need to First of all you need to connect power on Step 1 Input your account UserName and Password Note Contact us to get your account when needed LOJN Sy c TMs INC In ystem Prog ram via Internet Quality Delivery amp Service Start Check Remote Server Off Line ftp gigatms com tw Password x Step 2 Click Start Check to automatically check the firmware version from our FTP server Note 1 The WebISP will auto scan all Comm ports to search the reader or programmer 2 The WebISP will show the Update Information and list the update history LOJN GIGA 2 Quality Pel Show the update history June 23 2006 Fix Noise to Rese June 5 2006 Add stock refresh Camp Downloading File lt OK GoTo ISP Mode GNetPlus Protocol lt OK ISP Mode Erase Firmware lt OK Programming lt OK Update Finish Start Check Force r OnLine C OffLine ftp gigatms com tw UserName isp 24 PROMAG DESFire REV A Step 3 If your reader s or programmer s firmware out of date then WebISP will prompt you to update the firmware Click Update to begin Updating the firmware Step 4 Wait for the updating to finish And repeat step 2
13. Sector Data Output Data PROMAG DESFire REV A Mifare User Data Format DESFIRE READER will send out the data following the format as below the user data length defined by the Data Info At wiegand output format the data output length is fixed defined by Number Of Bits so the user data would be cut if longer than Number of Bits or the user data would be appended with zero 0 if shorter than Number of Bits Byte 0 Byte 15 Block 0 Data Info Application Block 1 USER DATA Max 128 Bytes Sector Block 2 Block 3 Data Info lolity ls biS bit0 Data Type 11b Data Length Data Type is fixed with 11b which meets any other data type of Card Holder information as MAD standard And data length is including the data with ending zero 0 so the number of data byte sent by DESFIRE READER is equal to data length with one less for RS232 output Example Data Length is 16 DESFIRE READER only send out 15 bytes for RS232 output PROMAG DESFire REV A Wires Assignment Color Symbol I O Description Red VCC IN Power Input DC 7 5V 12V Black GND IN Power Ground White DATA 1 OUT Wiegand Data 1 Signal ABA TK2 Clock Strobe Green DATA 0 OUT Wiegand Data 0 Signal ABA TK2 Data Yellow TXD OUT RS232 TXD To Host RXD RS485 for DF710 Blue RXD IN RS232 RXD To Host TXD RS485 for DF710 Orange CP OUT AB
14. ess Control amp Security Card Type IS014443A Mifare Class Mifare 1K Mifare 4K for MAD1 MADZ2 DESFire RF Frequence 13 56MHz RF Distance 50mm Using the MFA01 Mifare card of GIGA TMS INC DC Power 7 5VDC 12VDC Min 250mA 7 5V 150mA 12V Interface Wiegand 26 128 bits Standard Reverse RS232 2400bps 57600bps ABA TK2 40IPS Dimension H82 5mm x W46 5mm x D15 0mm Weight 120g Note 1 Mifare Class Mifare Standard 1K 4K Pro without Mifare Ultra Light 2 DESFIRE READER RF distance can reach up to 50mm with MFAO1 Mifare Standard 1K Card of GIGA TMS INC 18 PROMAG ANNEX B Wiegand Interface The Data 1 and Data 0 signals are held at a logic high level unit the reader is ready to send a data stream DESFire REV A The reader places data as asynchronous low going pulses on the Data 1 or Data 0 lines to transmit the data stream to Host The Data 1 and Data 0 pulses will allowable pulse width times and pulse interval times for the DESFIRE Reader Data 1 Signal Data 0 Signal Tpw i Tpi Tpw i Tpi Pulse Times Symbol Description Typical Time Tpw Pulse Width Time 100us 3 Tpi Pulse Interval Time 1 9ms 3 Wiegand Packet Without Reader ID Standard Default Parity Even MSB Data Bits LSB Parity Odd Reverse Option Parity Odd LSB Data Bits MSB
15. he MAD card Non MAD Sector Default 0 When the card is Non MAD format DESFIRE READER will only read the Non MAD Sector 1K Card Sector 0 15 4K Card Sector 0 39 For the Non MAD application user can freely define the Sector App Key KEY_A Default FFFFFFFFFFF2 App Key must be the same as the KEY_A of the card issued This means DESFIRE READER only can read the sector data on the card with the same KEY_A PROMAG DESFire REV A Encrypt Default None Fraud prevention Select Encrypt Mode None Encrypt 1 Encrypt 2 Encrypt 3 Encrypt 4 Encrypt 5 to protected your card data Remark Encrypt mode must to work together with the same encrypt mode of Mifare Card Issuer software Used Card Not issued by Mifare Card Issuer You have to indicate the data position in the card when the card is not issued by Mifare Card Issuer software And you must set the Offset Max 255 and base from zero form the beginning of sector and set your data Length Max 128 Example If your card data in the grey grid of sector you have to set the Offset 17 and set the Length 20 AID Sector or Non MAD Sector Block 0 0 1 2 3 4 5 6 7 8 9 10 21 12 13 14 15 Block 1 16 T7 18 15 20 21 22 BS 24 25 26 21 28 2 30 Sil Block 2 32 23 34 235 36 37 38 39 40 41 42 43 44 45 46 47 PROMAG DESFire REV A 3 Reader Settings
16. ion E kereke ke keke keke keke kk 18 ANNEX B Wiegand Wateri Ce iscsi cscsscsescesaspisnsialecncosatinnesiatiarecsahacadniahwciia teases keke keke keke keke kk k kr 19 ANNEX C ABA TK2 Interface keke kekekekekekeke yekeyek k k k k onsen 20 ANNEX D RS232 Interface keke ke kekekekekeke yekek k k k k kake ke k 21 ANNEX E External LED Buzzer Control eee keke keke keke ke kk 22 ANNEX F Order Information L kk keke keke keke keke keke kek kek 23 ANNEX G WeblSP Firmware Upgrade Utility ee 24 ANNEX H Configured Card keke keke kekekekekeke keke keke k k k keke kake kk 26 AN W RE Dlsa ainneoin E gg minal E 27 PROMAG DESFire REV A Mifare Configurable Sector Reader Overview DESFire Reader is a user configurable mifare sector data reader It can be configured to read mifare card with MAD1 MAD2 MAD3 standard in a mifare application open system or can be configured to read the user defined sector data Non MAD in a user defined closed system Output interface can be configured as an RS232 output or Wiegand output Wiegand output is selectable up to 128 bits DESFire Reader can also be set with a Reader ID number for multi unit communication Features 1 Support MAD1 MAD2 MAD3 standard and support customer MAD AID setting 2
17. ional 21 PROMAG DESFire REV A ANNEX E External LED Buzzer Control DESFIRE READER supporis the external LED Buzzer conitrol for Terminal or Host to prompt end user the card data is invalid or valid Use Brown wire to control the LED Buzzer of DESFIRE READER Examples as below Active High 1 Show External Invalid Status Data Output Alarm Control Brown i Min 100ms gt 2 Show Card Valid Status Data Output Alarm Control Brown gt Min 100ms Note 1 Send one pulse to show the Extern Invalid LED Buzzer Status T 2 Send three or more pulse to show the Card Valid LED Buzzer status X 3 You can configure the LED Buzzer status by DESFIRE READER utility 22 PROMAG ANNEX F Order Information DESFire REV A Power Adaptor Part Number Include Description DF 700 00 DF 700 00 DF700 DESFire Configurable Reader MF 700KIT 10 MF 7OOKIT Reader Kit WAS T0029 MF7XX Configure Cable DISK5238 Card Issue and Utility Software DC Power Adaptor 9VDC for MF7XXKIT MFA01 MFA01 Mifare Standard 1K Card MFAO4 MFAO4 Mifare Standard 4K Card 23 PROMAG ANNEX G WeblSP Firmware Upgrade Utility D reader s firmware I reboot your system and follow the steps as below the reader or programmer to PC nstall the WebISP include in CD
18. lication on the card File ID Default 0 File ID is 0 15 There are three file type Data file Value file and Record file DESFire Reader will auto detect the type and output the data Offset Length Default 0 5 The Data file will depend on the value to output data The Value file will be sent the value out The Record file will be sent the latest record data Access Key No Value Default 0 00000000000000000000000000000000 Key must be the same as the Read or Read Write KEY of the card issued This means DESFIRE READER only can read the data on the card with the same KEY PROMAG DESFire REV A 2 Mifare Settings Mark on Enabled Mifare Card and this tab will be visibled E Mifare DESFire Reader Utility 1 1R10 Configured Card _Rester TT LEBuzzer _ Card Information feros pooo o lo frrrrrrrrrr2 keya r7 Used Card Not issued by PROMAG card issuer Reader Auto Scan Update Reader Test Version Language DF700 Reader On COM1 MAD AID Default 4703 MAD Application Identifier number is authorized and assigned by Mifare net upon the customer s request for registered Application Identifier in a mifare application open system AID 0000h FFFFh Or it is also possible for the user to define the AID himself for the application in user defined closed system without registering into MAD group According to the AID DESFIRE READER can find and read the corresponding sector on t
19. tings as normal MS Fe neresen can Click Configure Card eS i MGS Length Data File 5 Me i Step 3 Type in correct Configured Key as same as reader configured before m Card Settings Configure Card pee MAD Admin Ke 208182838485 Put a empty Mifare Card Click Create Finish Take this card to approach the readers for configured this settings 26 PROMAG DESFire REV A ANNEX I History Rev A January 19 2009 Initial DESFire Reader 27 PROMAG DESFire REV A PROMAG GIGA TMS INC http www gigatms com tw mailto promag gigatms com tw TEL 886 2 26954214 FAX 886 2 26954213 Office 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Taiwan 28

Download Pdf Manuals