        Liebert GXT3 - Emerson Network Power
         Contents
1. Liebert   GXT3     Quick Start Guide     6000VA RTL630 Models    The Liebert GXT3 is shipped with the following items   e Terminal Block Communication terminals  e Compact disc with   o Liebert MultiLink    o Configuration program  o User manual  electronic version   e USB cable  one  2m  6 1 2 ft   long  e Rack handles with mounting hardware  e Plastic tower support base  one set  e Plastic Bezel  e Warnings  safety instructions booklet and WEEE recycling sheet  ISO 14001 compliance     If the UPS is intended to be installed in the Tower orientation  locate the support base and spacers then assemble the two  stand assemblies with an even number of spacers in each assembly  Insert the UPS between the support base  assemblies with adequate space between the assemblies as shown in the picture below  Note the display should be  located on the upper half of the unit in the Tower orientation  To rotate the display with the bezels removed  depress the  grooved tabs on the sides and rotate it 90 degrees clockwise   f the USP is to be installed in a rack enclosure  follow the  instructions provided with the rack mounting hardware for proper installation     Upper Bezel    Status Indicators  and Controls    Lower Bezel and  Battery Access  Door       The UPS is cord and plug connected using a L6 30P input plug  All wiring should be done in accordance to all local and  national electrical codes     The UPS is equipped with output receptacles  connect the equipment to be protected to th
2. e output receptacles     The GXT3 6000RTL630 is compatible with IT Power Systems  To configure the unit for operation on the IT Power  system  remove the 2 screws securing the cover plate in the lower right hand side on the rear of the unit and disconnect  the jumper  then replace the cover and secure with the screws     IT Power System  Connector   with cover removed        s  EMERSON   Network Powe   1 SL 23185QS6L630_RevO_09 2012    The Liebert  GXT3    6000 VA models ship without the internal battery installed  Located the internal battery kit  model  number GXT3 240BATKIT  and follow these steps to install the battery     1  Loosen and remove the screws on the battery door and remove the battery door and set aside the screws and  door for reassembly   2  Insert the two battery trays and connect the plugs to the mating receptacles   3  Gently push the battery wiring into the compartment making sure that the wiring will not be pinched when the  battery door is reinstalled    4  Reinstall the battery door and secure using the screws that were removed in step 1    5  Locate the plastic bezel from the shipping box and attach the bezel to the UPS taking care to align the fastening  clips on both ends before inserting them into the holes    6  If your application requires the use of external battery cabinets for longer back up time requirements  connect the  first battery cabinet to the UPS with the cable provided with the battery cabinet  Note  it does not matter which  connec
3. es attention     In addition to the fault indicator being illuminated  one or more of LED segments of battery level indicator will also be  illuminated to provide a diagnostic aid to the user  as shown below    A B C      The descriptions are listed in the following table     Indicator   Diagnosis Audiblealarm __           gt Z  gt     A___  On bypass due to over temperature condition  1 second beep every 4 seconds     B   On bypass due to DC bus overvoltage  1 second beep every 4 seconds   _        C   On bypass due to DC DC power supply failure  1 second beep every 4 seconds   C D  C E        A amp C       mn    PFC failure  1 second beep every 4 seconds   On bypass due to inverter failure  1 second beep every 4 seconds      E  A  C  E  A amp B UPS Failure  includes dual fan failure  single fan failure under certain conditions and  battery charger failure  and continuous alarm  C amp E    A amp C     CRE UPS shutdown by command from communication  USB or Liebert IntelliSlot    port    no audible alarm   AC Input Indicator  LED flashing    N reverse  Battery Indicator Internal battery source not available  continuous audible alarm   check battery  Flashing connection  power down and reboot UPS    a     Utility power voltage or frequency is out of tolerance  bypass is unavailable    Single Phase UPS  amp  Server Cabinets Technical Support  liebert upstech emerson com   800 222 5877   Outside North America   00800 1155 4499       Emerson Network Power Worldwide Locations    Un
4. ited States Europe   1050 Dearborn Drive Via Leonardo Da Vinci 8   P O  Box 29186 Zona Industriale Tognana  Columbus  OH 43229 35028 Piove Di Sacco  PD  Italy  800 222 5877  39 049 9719 111    Fax   39 049 5841 257  Asia  29 F  The Orient Square Building  F  Ortigas Jr  Road  Ortigas Center  Pasig City 1605  Philippines   63 2 687 6615  Fax   63 2 730 9572       5    EMERSON  4 SL 23185QS6L630_Rev0_09 2012    
5. tor is used on the battery cabinet   f more than one battery cabinet is used the additional cabinets then  connect to the adjoining battery cabinet     Battery Kit Handle       Internal Battery Kit   1 of 2   GXT3 240BATBKIT    Output Circuit Breakers            Liebert GXT3 UPS          AA    GXT3 6000RTL630      gt  m pe External Battery    ele Cabinet Connector  for    Maintenance GXT3 240VBATTUL    Bypass Breaker    IT Power System    Input Circuit Breaker Access Cover    s  EMERSON     Network Powe     2 SL 23185QS6L630_RevO 09 2012    The Liebert   GXT3  UPS is ready to be powered     ok    a    eS    Ensure the maintenance bypass breaker is in the open position and that the guard is secured in place    Ensure that the REPO connecior on the rear of the unit has a jumper between pins 1 2 of the REPO connector or  properly wired to an Emergency Power Off circuit  normally closed     Install any optional Intellislot communication card into the Intellislot port on the rear of the unit    Close the input breaker in the panelboard that provides input power to the UPS   Close the input breaker on the rear of the UPS unit  Note  the UPS will now have power and the AC Input  indicator on the display should illuminate  The UPS will also begin to charge the internal batteries at this point  so  there will also be battery capacity LEDs illuminated    The Liebert GXT3 UPS has customizable settings that might be required depending on the application  Please  review the CD that ships 
6. with the UPS unit for the steps to use the configuration program and make any  necessary changes  Once that is complete  proceed to the next step    Close all output breakers on the rear of the UPS   If external battery cabinets are used  close all breakers on the rear of each battery cabinet   Press and hold for about 4 seconds  the    ON    button on the UPS display  Note  this will apply power to the output  receptacles via the internal bypass and the bypass indicator will be illuminated along with an audible beep       Over the next several seconds the UPS will perform the self checks and startup routine then automatically    transfer the connected equipment to the inverter power  Once that is complete  the bypass indicator will turn off  and the inverter indicator will illuminate     The UPS is now running in normal operation mode providing protected  filtered power to the connected equipment     Battery Level Indicators        Load Level Indicators    Fault Indicator A Nea AT zi  aie Bypass Indicator    AC Input Indicator Inverter Indicator    On Alarm Silence Manual     ry eta cxt  Battery Test Button Na anal oy       of    6000VA    otandby Manual Bypass Button Battery Indicator    Pp  he    EMERSON    3 SL 23185QS6L630_Rev0_ 09 2012    Troubleshooting    The following symptoms indicate the Liebert   GXT3 is malfunctioning   e The relative indicators illuminate  indicating the UPS has detected a problem   e An alarm buzzer sounds  alerting the user that the UPS requir
    