Home
DIGI CROWN PROBING LINE Marposs presents Digi Crown, an
Contents
1. Digi Crown box Reading rate s 250 50 in standard version 9 000 in version with additional RAM Sampling storage Current absorption Operating temperature O to 60 C Storing temperature 20 to 70 C Degree of protection IP43 Power supply 7 5Vdc 10 30 Input connection to sensor via Lumberg IP68 connector Output serial communication communication towards bus via Digi Crown protocol Pencil Resolution u 0 05 0 05 Dimensions see specific section page 16 DIGI CROWN 232 USB Communication interface to be used for connecting the Digi Crown network directly to an 5292 or a USB PC port It is physically placed in the second position of the network on the PC side and is always preceded by a Digi Crown psu power supply interfa ce unit The connection to the PC is made by means of a 9 pole D sub connector and 8 2 m cable Its main functions include managing the signal exchange between the RS232 USB port of the PC and the RS485 serial interface of the measuring bus supplying the synchronization sine wave for the Digi Crown box interfaces e managing the network diagnostic information Digi Crown 232 USB to be used with Digi Crown psu interface 1 RS232 channel full duplex hardware handshake RTS CTS 1 virtual COM with USB interface USB 1 1 2 0 compatible Serial RS485 interface half duplex Digi Crown protocol Current absorption 50 mA Communica
2. DIGI CROWN PROBING LINE Marposs presents Digi Crown an innovative digital technology modu lar sensor system for dimensional measurements and quality control during production Digi Crown offers a new standard for the measurement of parts obtained by machining on machine tools or through molding processes as in the glass ceramic and plastic industry e EXCELLENT METROLOGICAL PERFORMANCE e MODULARITY e AFFORDABLE EASY ASSEMBLY RELIABILITY FLEXIBILITY e EASY MAINTENANCE Digi Crown is a flexible measuring system from 1 to 372 sensors configured in networks from 1 to 12 that can be connected to a PC via RS232 serial interface or RS485 dedicated interface cards for PCI o ISA bus Excellent metrological mance All sensors which are certified over the entire measuring range from 1 to 20 mm make it possible to measure different sized parts without the need for zero setting or retooling The set up is easy and fast and only one master is used perfor Modularity The measuring network can easily be modified by adding or removing elements in order to create a network that is suitable for the needs of the new application Each element is tested individually So all the components of the line are interchangeable Combinations of analog and digital sensors and also logic I Os can be mixed within the same network Affordable The individual elements can be DiGi CROWN PROBING LINE
3. 1 combined in order to use only the units that are needed to solve the application modularity one Easy setup one click to be ready The automatic identification of the components installed in the network is an exclusive feature of the Digi Crown driver Just a simple CLICK for enabling the automatic configuration and the setup of the network becomes a quick task reducing the possibility of configuration errors and manual operations Moreover the sensors can be easily replaced without further changes in the configuration software because they are automatically recognized by the system The Digi Crown driver is supplied along with dedicated Marposs software packages Reliability Digi Crown sensors are sturdy and reliable Thanks to Marposs proven technology and the IP65 waterproof structure they are suitable for use in shop floor environments The measuring networks make use of the properties of RS485 serial communication for a high speed data exchange over distances up to 1 Km Flexibility The measuring network can be connected to Marposs E9066 industrial PCs or commercial PCs The connection is made via RS232 serial interface or dedicated interface cards for PCI or ISA bus Besides the dedicated SW packages for measuring management there is also the Digi Crown driver library that makes it possible to integrate the network into application SW developed by third parties Easy maintenance The modularit
4. Spring strength mE 1596 SOFT TOUCH Calibration frequency KHZ 0 045 0 014 0 014 I 0 008 7 9 Calibrated to V RMS Current mA RMS 3 54 with load 1 MOhm 360 pF 9 Input Output phase displacement Specific sensitivity mV V mm K difference in mm between master zero and dimension to be measured Dici CROWN PROBING LINE lt 10 115 11 TRANSDUCERS AND EASUREMENT TRANSMISSIONS i How TO ORDER 5439 05 41 SNOISSIINSNVYL 3 3 co eS JJ ep C ra rr T1 eS JJ lt C U Go ep Go C M r INTERFACES a DESCRIPTION GI CROWN BO DIGI CROWN BOX ram co DIGI CROWN 232 DIGI CROWN USB DIGI CROWN PSU 110 240 Vac 7 5 Vdc DIGI CROWN PSU 24 Vdc 7 5 Vdc DIGI CROWN I O SINK DIGI CROWN SOURCE DIGI CROWN ONLY INPUT DIGI CROWN PCI DIGI CROWN ISA A A Mm Mm Mm x OO OO oO ACCESSORIES SLINA AV1d4SIQ JINOWLIITI ANY SYOLVIIGNI DESCRIPTION DIGI CROWN PBB END LINE CONNECTOR DIGI CROWN BUS FOR DIGI CROWN BOX 232 I O DIGI CROWN PSC FOR DIGI CROWN PSU EU PLUG USA PLUG UK PLUG EU CABLE USA CABLE ZzZzZZzZZ Zz NOILISINDIY VIVG d0O3 S3JX08 J0Vdd31NI Sw PACKAG
5. ES QSPC E EASY ACQUISITION MARPOSS DRIVER LIBRARY FT CO CROWN PROBING LINE 12 CONNECTION CABLE DESCRIPTION CONNECTION CABLE 2 mt CONNECTION CABLE 6 mt CONNECTION CABLE 10 mt CONNECTION CABLE 15 mt CONNECTION CABLE 25 mt Digi Crown pencil probe heads STANDARD DESCRIPTION AXIAL SPRING RANGE mm TRADE NAME AXIAL SPRING AXIAL SPRING AXIAL SPRING AXIAL SPRING RADIAL SPRING RADIAL SPRING RADIAL SPRING RADIAL SPRING RADIAL PNEUM RADIAL PNEUM RADIAL PNEUM RADIAL PNEUM AXIAL PNEUM AXIAL PNEUM AXIAL PNEUM Pp p gt gt p gt p gt p gt p gt gt gt p gt p gt gt gt gt gt AXIAL PNEUM SOFT TOUCH DEscRIPTION AXIAL SPRING RANGE mm TRADE NAME AXIAL SPRING DO2L AXIAL SPRING DOSL AXIAL SPRING D10L AXIAL SPRING D20L RADIAL SPRING RDO2L RADIAL SPRING RDOSL RADIAL SPRING RD10L RADIAL SPRING RD20L RADIAL PNEUM PDO2L RADIAL PNEUM PDOSL RADIAL PNEUM PD10L RADIAL PNEUM PD20L AXIAL PNEUM PADO2L AXIAL PNEUM PADOSL AXIAL PNEUM PAD10L AXIAL PNEUM 2 RADIAL PUSH VACUUM PVDO2L RADIAL PUSH VACUUM PVDOSL RADIAL PUSH VACUUM PVD10L RADIA
6. L PUSH VACUUM PVD20L AXIAL PUSH VACUUM PVADO2L AXIAL PUSH VACUUM PVADOSL AXIAL PUSH VACUUM PVAD10L PP p pp p p p p ppp gt p p gt p pp gt p gt p gt p gt gt gt gt AXIAL PUSH VACUUM Mini CELL D124 DESCRIPTION B CONTACT UP RANGE mm 0 4 PVAD20L TRADE NAME D124 Dict CROWN PROBING LINE TRANSDUCERS AND cO lt N ES cc N lt LL FORKS AND RING GAUGES BORE GAUGES LINE INTERFACE BOXES INDICATORS AND ELECTRONIC BENCH GAUGES FOR DATA ACQUISITION DISPLAY UNITS SOFTWARES PROBES DIMENSIONS mm Digi Crown Probe STANDARD VERSION ANY SYFINGSNVUL SNOISSIINSNWUL LN3IW3d SV3lN Long Range CL Standard Pneumatic Only for pneumatic version A A1 A2 A3 C refer to the electrical zero The 90 cable deflector is always supplied with the axial cable heads Dici CROWN PROBING LINE 14 Digi Crown probe SOFT TOUCH VERSION TRANSDUCERS AND EASUREMENT TRANSMISSIONS Long Range CL Standard Pneumatic Standard Pneumatic Standard Pneumatic Standard Pneumatic Only for pneumatic version A A1 A2 A3 C refer to the electrical zero The 90 cable deflector is always supplied with the
7. STANDARD Measuring force at natural zero N 25 SOFT TOUCH Spring strength mm 15 Cable lenght m SOFT TOUCH STd connector Lumberg IP68 Calibration frequency KHz Calibration to V RMS 3 54 with load 1 Current mA RMS Input Output phase displacement n Specific sensitivity mV V mm 2 Digi Crown probe PNEUMATIC PUSH MEASURING RANGE mm CABLE AXIAL CABLE RADIAL CABLE AXIAL CABLE RADIAL et CODE SOFT TOUCH c CODE STANDARD Onan CODE MEASURING RANGE mm 13447700130 lt r TTEN r0 Accuracy error um Total travel mm Repeatability error um 0 2 k 1 0 0 0 6 k 2 1 2 k 2 Thermal drift at zero um C Measuring force at natural zero N 25 6 14 5 psi lt 0 25 aU 25 6 14 5 psi 0 4 D4 lt 0 5 lt 0 5 0 4 1 bar _ a 6 14 5 psi 0 8 2 5 0 6 2 3 0 7 2 4 STANDARD Spring strength Y 15 0 08 0 03 0 02 Measuring force at 0 5 2 bar 0 125 2 bar 0 5 2 bar 0 125 2 bar 0 5 2 bar 0125 2 bar 0 5 2bar 0125 2 bar natural zero N 25 7 3 29 psi 0 18 1 23 1 825 29 psi 0 09 1 41 7 3 29 psi 0 18 1 23 1 825 29 psi 0 09 1 41 7 3 29 psi 1 825 29 psi 0 18 1 23 0 09 1 41 7 3 29 psi 0 18 1 23 1 825 29 psi 0 09 1 41
8. axial cable heads Dici CROWN PROBING LINE 15 l m INTERFACES OVERALL DIMENSIONS mm Overall dimensions of Digi Crown box Digi Crown 232 Digi Crown psu Digi Crown i o Digi Crown bus and Digi Crown psc interfaces ANY SYFINGSNVUL SNOISSIINSNVYL LNJWJYNSVIN Fastening Wing 79 by means of fastening wings s 54 by means of connector gt xb O Yn oO Cc n 9 O 5 Cc Cc Q 8 a or Fixing dimensions to the Digit Crown bus Digit Crown pse distance between contact and fulcrum For a full list of address locations please consult the Marposs official website www marposs com www testar com D6L01201G0 Edition 10 2010 Specifications are subject to modifications Copyright 2010 MARPOSS S p A Italy All rights reserved MARPOSS and Marposs product names signs mentioned or shown herein are registered trademarks or trademarks of Marposs in the United States and other countries The rights if any of third parties on trademarks or registered trademarks mentioned in the present publication are acknowledged to the respective owners Marposs has an integrated system to manag
9. ble is made out of corrosive resistant material and has been designed in com pliance with the compatibility regulations EMC standard directive 89 336 EEC Standard version All the models are equipped with carbide contacts The front actuation part is equipped with a Fluoroelastomer gasket that in addition being highly resistant to chemical agents ensures an IP65 waterproof integrity Spring versions have a 0 8 N measuring force Should a different force be needed an extensive range of optional springs is available O Soft Touch version All the models are equipped with standard nylon contacts but optional carbide contacts are available The front part does not have a gaiter in order to ensure repeatability and low measuring force _ Spring versions have a 0 3 N measuring force There are also some sprin gless PUSH VACUUM versions that make it possible to measure even with a 0 1 N force In this case the measuring force is directly proportio nal to the pressure of the air O Miniature measuring cell D124 is a miniature measuring cell that can be applied in simple as well as multidimensional measuring applications The 7 x 7 x 31 mm compact dimensions the IP67 protection degree the replaceable contact and the shielded cable allow solving measuring tasks for limited space applications still maintaining great accuracy and reliability The fixing of the D124 is done with an M3 screw while for the set up a special tool
10. d measuring applications industrial process control real time SPC and closed loop machine tool control From simple manual gauging to complex automatic gauging applications or network requirements the E9066 scalable hardware and open connectivity provides a cost effective solution for any need TRANSDUCERS AND EASUREMENT TRANSMISSIONS MERLIN 8 4 colour LCD display unit designed for simple measuring applications up to 16 sensors measurements and basic statistic analysis Merlin represents a new concept of gage computer using the same technologies created for PDA and portable electronics for data collection from traditional or wireless measuring devices Embedded technology allows small dimensions the whole system footprint is smaller than an A4 sheet of paper Merlin gage software based on Microsoft Windows CE 5 0 guarantees a friendly and easy to use operator interface It features the following ports 10 100Mbps Ethernet LAN 4USB 1 RS232C CROWN PROBING LINE 9 SNOISSIINSNWYL 3 34 5 3 ANY SYFINGSNVUL SOFTWARE PACKAGES FOR MEASUREMENT ACQUISITION The Digi Crown driver is available in any of the MARPOSS software packages for measurement acquisition such as QUICK SPC EASY ACQUISITION or MARPOSS DLL Digi Crown allows the automatic identification of the components installed in the network Thanks to this exclusive feature the setup of the network becomes a quick and easy tas
11. dc 10 30 Bus current absorption 40 mA 40 mA 50 mA Power supply EXT 24 Vdc 20 24 Vdc 20 Current absorption without any output active 25 Voff gt V I O 5V Von lt V I O 15V 100 mA Vout lt 0 4 Vdc Optoinsulated Protected Input specifications Output specifications Voff lt 5 V Von gt 15 V 100 mA Vout gt VI O 2V Optoinsulated Protected Off gt 500 KQ On lt 3300 KQ Max output current 600 mA DiGi CROWN Bus Regarded as the basic element of the network It makes it physically possible to create the network and in actual fact forms the bus through which the communication between the individual measuring points and the PC takes place via a 232 serial interface or card for PCI ISA bus Main characteristics include Crown i o or Digi Crown 232 interface quick release spring makes it possible to remove the interface simply DIGI CROWN PBB Mounting guides that facilitate the insertion of the Digi Crown box Digi The DigiCrown pbb push button implements the I O unit allowing to con trol eight digital inputs by means of ON OFF buttons and a four positions selector Typically the buttons are used for START STOP sequences and data acquisitions while the selector for setting a different working piece to be measured Besides the 15 pin female D sub port used for connec ting the I O ONLY INPUT mo
12. dule the push button includes a 9 pin fe male connector for linking an external footswitch Dici CROWN PROBING LINE 6 DIGI CROWN PSU Network power supply interface ALWAYS used in applications with Digi Crown RS232 serial interface Available in 2 versions e Vin 100 240 Vac and Vout 7 5 Vdc e Vin 24 Vdc and Vout 7 5 Vdc The Digi Crown psu may also be used in an application with Digi Crown pci or isa interface card This need arises when the application has a very long cable voltage drop along the cable or when the PC power supply unit is not powerful enough Digi Crown psu 110 220 Vac 24 Vdc Power supply 100 240 Vac 47 63 Hz 400 mA 24Vdc 20 20 Output 7 5 Vde 1 7A 7 5 Vde 1 8A Current absorption Operating temperature O to 40 C Storing temperature 20 to 70 C Degree of protection IP43 on interface side with bus Inversion protection with automatic reset Overload protection with automatic reset Dimensions see specific section page 16 DIGI cRown Psc This connection interface is used only in combination with the Digi Crown PSU power supply interface It is mechanically identical to the Digi Crown bus only the connectors are male instead of female in order to prevent an incorrect connection These two connection elements can be fastened in two different ways from under by means of a nut integrated in the base from above by means of two plastic clam
13. e the Company uality the environment and safety attested by ISO 9001 ISO 14001 OHSAS 18001 and QS9000 T amp E certifications Marposs has further been qualified EAQF 94 and has obtained the Q1 Award CROWN PROBING LINE 16
14. ensions Standard short ISA slot Required power 25 W 311 31 units with max cable length 10 m Digi Crown protocol Protocol easy ASCII strings lt CR gt terminated single unit addressing with broadcast command capability gt RS232 Mode E 8 1 with baud 4 800 9 600 115 200 bit s RS232 comm protocol full duplex hardware handshake capability break capability RS485 Mode 1 8 1 with baud 9 600 or 208 333 bit s RS485 comm protocol half duplex automatic multiprocessor addressing capability RS485 Network length up to 1km depending on configuration Number of units per network Max 31 Measurement syncronization 75kHz on RS485 bus Dici CROWN PROBING LINE 8 INDUSTRIAL PCs FOR MEASUREMENT ACQUISITION E9066 INDUSTRIAL PCs The family of E9066 Industrial Computers are a rugged PC based industrial system designed to provide highly accurate and repeatable gauging results for a wide variety of measuring applications even under harsh shop floor environments These Industrial Computers can be provided with various IP rated cabinets for desktop solutions or be directly deployed in panel mount and swing arm applications All devices are designed to withstand the abuse of severe shop floor environments while complying to international standards for EMC safety and noise immunity When bundled with our Quick SPC software package they offer unparalleled performance for real time data acquisition an
15. is supplied with the measuring cell Each D124 is provided with a calibration certificate to guarantee the accuracy of the cell Plug amp Play sensors All models are interchangeable and can be adapted in any previously configured network The Digi Crown box interface can automatically acquire both the identifi cation data of the sensor and the mapping data for the linearization func tion All the sensors are 100 tested and supplied in a dedicated packa ge The package also includes the calibration certificate and the installa tion and user manual for correct use of the product CROWN PROBING LINE 4 INTERFACES This section includes all the interface modules for configuring the Digi Crown digital network 9 DIGI CROWN Box The Digi Crown box interfaces the sensors to the bus A sturdy mechani sm that is easily inserted into the Digi Crown bus and manages the si gnal of the sensor It is equipped with a u processor its main functions include acquisition of sensor identification data e acquisition of measurement e A D conversion of signal and achievement of linearization achievement of RS485 serial transmission and through the bus of an active exchange of information with the PC in order to supply the data for measurement processing In the version with internal RAM it can manage up to 9 000 pieces of sampling for vectorized dynamic measurements TRANSDUCERS AND EASUREMENT TRANSMISSIONS
16. k auick spc STATISTICAL PROCESS CONTROL SPC AND QUALITY CONTROL SOFTWARE READY TO RUN Templates and wizard driven programming interfaces allow an easy safe and ready to use software Self explanatory with its spreadsheet programming interface Explorer like navigation and on line manuals Mouse free Interface Safe and reliable with checks on programmed data consistency data back up and restore utility multi level user security access REDEFINING THE CONCEPT OF FLEXIBILITY Fully customizable software environment to change page layouts function keys application templates printouts customers based statistical evaluations and more Powerful and versatile capable of connecting to a variety of analog and digital measuring devices and machine tool CNC s Native 32 bit Windows software Comprehensive fully integrated software modules for data acquisition measurement elaboration statistical analysis machine tool compensation network integration and data storage EASY ACQUISITION This software package allows data collection and statistical analysis SPC It works on an Excel platform and makes it possible to use a normal worksheet for carrying out the following functions aa ICR SSES e acquisition of measurement values from network i a i i creation and display of static and dynamic measurements with tolerance O and status values management of measurement zero setting if required data c
17. ollection relevant to acquired measurement values e statistical analysis SPC of the measurement values stored in the data collection available only with Easy Acquisition SPC printing customized if wished of data collection and SPC values a Er J k for the Windows operating System MARPOSS DRIVER LIBRARY Allows third party software to interface with the following Marposs devices 1 E4N 2 Easy box 3 Gage box 4 Quick Read 5 Quick Digit 6 Digi Crown CROWN PROBING LINE 10 Digi Crown probe SPRING MEASURING RANGE mm AXIAL CABLE SOFT TOUCH RADIAL CABLE AXIAL CABLE STANDARD RADIAL CABLE TRADE NAME _TRADE NAME The Vacuum Retract function contact pneumatic can be added using the accessories cede 4430245031 or 4430240679 ti is also necessary to substitute the standard springs with the following ones RD 02 spring 1024099711 RD 05 spring 1024099721 RD 10 Range of accuracy mm spring 1024099735 spring guide 1024099660 1 2 5 10 20 Accuracy error um Total travel mm 0 2 k 1 1 25 0 2 k 1 0 6 k 2 0 6 k 2 1 2 k 2 10 6 Repeatability error um lt 0 15 lt 0 15 20 6 0 2 0 4 0 4 Thermal drift at 0 um C TOO SY 0 25 lt 0 25 lt 0 25 lt 0 5 Measuring force at natural zero N 25 STANDARD Spring strength N mm 15
18. ps included in the package as shown in the figure END OF NETWORK CONNECTOR 9 pole D sub connector equipped with a control circuit and a warning LED It is the last element of each measuring network and is fitted on the last Digi Crown bus It supplies 3 pieces of information about the operation of the bus 1 LED off voltage in bus NOT Ok 2 LED on green light voltage in bus OK 3 LED flashing green orange light Communication in bus active This connector is particularly useful for monitoring the network in order to ensure correct operation and for finding out when the voltage in the bus is not adequate LED off In the latter case an auxiliary power supply unit Digi Crown psu must be added DiGi CROWN PROBING LINE 7 TRANSDUCERS AND MEASUREMENT TRANSMISSIONS DIGI CROWN PCI AND DIGI CROWN ISA RS485 serial interface cards for PC bus available in two versions Digi Crown pci for PCI bus Digi Crown isa per ISA bus Each card can manage 2 networks therefore up to 91 1 91 sensors via 2 9 pole D sub connectors These interfaces achieve the RS485 serial communication with the network which can manage the measuring device from a distance of up to 1 Km They are designed to supply power directly to the network and to manage the communication protocol They supply power to all the sensors 31 1 31 directly using the PC power Supply up to a maximum distance of 10 m The perfo
19. rmance depends on the specifications of the PC that has been chosen the rating of the power supply unit must be adequate One of the most important characteristics of these interfaces is the possi bility of carrying out measurements where there is a synchronization betwe en sensors of the same network sensors of different networks sensors of networks connected to different cards ANY SYFINGSNVYL SNOISSIINSNWYL LNIWSIYNSWAIN The interfaces are easily installed because their drivers are already inte grated in the measurement managing SW packages that are provided such as QSPC Easy Acquisition a Marposs DLL Digi Crown pci Power supply from standard PCI bus 5 V Power absorption 1 5 W power towards networks Inputs Outputs Digi Crown HW amp protocol compatible RS485 speed see Digi Crown HW amp protocol definition Operating temperature 0 to 50 C Maximum network length see Digi Crown HW amp protocol definition Number of networks per card 2 Dimensions Standard short PCI slot Required power 25 W 31 31 units with max cable length 10 m Digi Crown isa Power supply from standard ISA bus Power absorption 1 5 W power towards networks Inputs Outputs Digi Crown HW amp protocol compatible RS485 speed see Digi Crown HW amp protocol definition Operating temperature standard PC Maximum network length see Digi Crown HW amp protocol definition Number of networks per card 2 Dim
20. tion Data interface Operating temperature 0 to 60 C Storage temperature 20 to 70 C Degree of protection IP43 Power supply 7 5 Vdc 10 30 9 pole D sub female RS232 connector Type A USB connector Dimensions see specific section page 16 Dici CROWN PROBING LINE 5 DIGI CROWN 1 0 START ZERO SETTING stage or for SINK and SOURCE version NOISSIINSNVUL LN3W3d nSV3lN SYJJNASNVYL Max output current 100mA PART TYPE I O interface for logic signal management It is used for controlling sole noid valves or lamps not directly but via power contacts or pushbuttons for measuring cycle management such as during the START CYCLE or It can control up to 8 drivers working as INPUT or OUTPUT example 4 IN and 4 OUT or 2 IN and 6 OUT 24V external power supply to be wired to the 15 poles connector Cable length 0 5m The IN OUT connector is a 15 poles standard Cannon ONLY INPUT version It can manage up to 8 INPUTS by means of the Digi Crown pbb push button or by generic push buttons properly wired to the connector Cable length 2 5m No external power supply required the Digi Crown bus supplies the unit The push button and the INPUTS are connected to the unit through the 15 poles male connector Digi Crown I O SINK type SOURCE type ONLY INPUT Order code 7671000000 7671010000 7671020000 Bus power supply 7 5 V
21. y of the system makes it possible to replace the sensor alo ne thus cutting down servicing time maintenance and storage costs The system is also equipped with a self evident diagnostic function TRANSDUCERS AND MEASUREMENT TRANSMISSIONS ANY SYFINGSNVYL Digi Crown D124 SNOISSIINSNVYL LNINWJYNSVIN Digi Crown pencil probe E9066 line or Commercial PC Digi Crown pei MAX 6 Digi Crown isa MAX 4 End line connector Digi Crown bus Dici CROWN PROBING LINE 2 Digi Crown box TRANSDUCERS AND EASUREMENT TRANSMISSIONS Digi Crown i o Digi Crown 232 OPTION 1 RS 232 interf Digi Crown usb OPTION 2 RS 485 card Digi Crown psc Digi Crown psu DiGi CROWN PROBING LINE 3 SENSORS A complete range of sensors with 1 2 5 10 and 20 mm measuring ranges are available to meet all customers application needs NOISSIINSNVUL LN3W3d nSV3lN ANY SYFINGSNVUL There are 13 Standard models with Fluoroelastomer gaiters and 25 Soft Touch models without gaiters Soft touch probes are used in applications where low measuring force is required such as in the glass and plastic industry Common characteristics All sensors are available in versions with spring or pneumatic push The sensor body made out of steel 6 8h6 is where the identification data type code and serial number is laser marked The transducer is an LVDT with excellent linearity The 2 m ca
Download Pdf Manuals
Related Search
Related Contents
Samsung HMX-W200RN Manual de Usuario SAS-933EL SERIES BACKPLANE USER'S GUIDE Bosch Appliances MUM 7000 UC Blender User Manual 取扱説明書 - 山梨産業保健総合支援センター Consulter la version pdf Service Manual FW-C3, FW-C30, FW-C35 EZ Lock™ Manual do Usuário Manual del Usuario User Manual MANUAL DE INSTRUCCIONES Read this first Copyright © All rights reserved.