1. Ltd FD2000S OLT Installation User Manual Diagram 2 Uplink Slot Diagram GEPON OLT FD2000S chassis provides 8 gigabit uplink ports Physical Interface type is SFP slot Every port could be configured as electrical port or optical port through software configuration The default configuration is shipped with electrical SFP Uplink port supports port trunk management Through the port trunk whole equipment support 8G uplink bandwidth at most Each uplink port is 1 25 gigabit except special configuration users could choose one port or muti ports to connect the uplink device based on the actual networking deployment Port Management Network management port is used for the network management for users This port is in switch control module Please see the diagram as follows PWR ALM FAN RST Ora Deni CA Oc Qae CymaC je Jo O CONSOLE MANAGE Diagram 3 Management Port Diagram GEPON OLT FD2000S provide 1 10M Ethernet out band management port 1 CLI management port used for managing the OLT and ONU equipment Besides specified management port every uplink port could use as in band management port no need special configuration except VLAN Management PON Port PON port used to connect networking between ONU and ODN Physical Interface type is SFP port standard is 1000BASE PX20 When you want to use it you should install OLT module And it can connected 64 ONU for every port 2 Equipment Installation 2 1 Installat
2. e ro erre nena 11 3 2 CHECK OUT OLT S WORKING STATUS ee ree m 11 3 2 1 Check out ONU Registration eoe ee a ree erre nein natnram iua I nee inen etre 11 3 2 2 Network Connection Checkout en 12 3 2 3 Network Management Checkout eere ann ene tn re enna 12 4 DAILY MAINTENANCE erreur er ener rennen ne nnn nenne nnne nen nennen nenne nnne nenne nennen 12 5 DEFAULT CONFIGURATION ere eren nnne nnn nnne nnne n nenne nennen nenne nenne nen 13 6 APPENDIX A TROUBLESHOOTING eurer nennen nn 14 7 APPENDIX B OLT TECHNICAL SPECIFICATION 16 7 1 GEPON OLT SYSTEM SPECIFICATION 16 7 2 FD2000C CHASSIS SPECIFICATION nn nnn Ea 18 7 3 FD2000M SWITCH CONTROL SPECIFICATION 18 7 4 FD2102T PON SERVICE CARD SPECIFICATION 19 8 ENDING 20 00 2022 0c 2 rrr ITI mne nennen nennen nennen nnne nennen nnn nnne nenne nnn enne nnn 20 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual 1 Product Introduction 1 1 Equipment Brief Introduction EPON OLT GEPON OLT FD2000S is EPON
3. filters module need to clean once per 1 3 months When cleaning taking down the dust filter module and rinsing it directly than dry out for next time use 2 3 3 Fan Module Installation Fan module parts will is installed in OLT chassis in the factory no need to install again After you change new one or plug out to clean you need to install by yourself Fan modules installed in the back on the right side of chassis When you install push it into the chassis gently along the guide rail then fixed with screws Please see the diagram below Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual Fan Module Diagram 6 Fan Module Installation Diagram 2 3 4 PON Card and Switch Control Card Installation OLT GEPON OLT FD2000S equipment has two kinds of Card PON Card and Switch Control Card The PON card and switch control card have been installed in OLT chassis during production process There is no need to install PON card or switch control card upon the receipt of parcels Switch control card is installed in the upper side marked as NMS slot PON card is installed under the switch control card marked as 1 4 PON port slot There is no difference among these four PON port card slots Users can install the PON port card to one or more slot if needed Installation steps as follows 1 Hold the card and push into the chassis gently along the guide rail 2 With the help of panel handle push the cards i
4. ATION PREPARATION 6 2 2 OPEN PACKAGE AND CHECKOUT 7 2 3 INSTALLATION OF EACH MODULE 7 2 3 1 Power supply module Installation eee men 7 2 3 2 Installation of Dust filter module eee enne nn nn nnn nen 8 2 3 3 Fan Module Installation e eee eene ne nnne nen nnne nnn ne nenne 8 2 3 4 PON Card and Switch Control Card Installation I 2 3 5 SFP Module Installation o ann nnn nnn nanan eee erdt sae 10 2 4 CABLE CONNECTION 10 24 1 Uplink SEP Service Port mm re enne nente ce eee 10 2 4 2 PON Port Connection eoe nn nn nn nn 10 2 4 3 Ground Line Connection m enn epit I eater ene e e ee rrt ten eterne 10 2 4 4 Management Port Connection nnn emen nnnm 11 3 OLT POWER SUPPLY AND WORKING STATUS CHECKOUT 11 3 1 CHECK OUT POWER SUPPLY eo e erre e eroe erroe
5. J45 connector has bad connection or net wire is more than 100 meters Check if uplink port works Check if SFP is plugged in the right way If it doesn t work please plug it out and insert for several times Working mode of SFP port is Fiber PS factory default setting is Copper mode Check if optical module matches with its parameter Such as SM MM or wave length Please check the both end s link power budget belongs to the range of the OLT and ONU SFP s receiving power Whether it s saturation optical When using uplink SFP optical module the link fails or work abnormall d power whether it s receiving sensitivity Check if patch cord bending excessively Check if port connector is correct patch cord connector and module interface contacts well Check optical connector is clean Check if using right connecting RJ45 DB9 serial cable in package CONSOLE Port can t connect Check PC bandwidth rate is the same with GEPON OLT successfully setting factory fault setting band rate is 9600bit s If you use PC USB to connect by DB9 USB please check whether driving install correctly OLT GEPON OLT s management port is fixed at 10M full duplex working mode Please check the uplink device working mode is match with OLT uplink port s working mode Generally speaking the connected MANAGE PORT can t work l l uplink device port could be configured as auto negotiation or fixed 10M full duplex working mode 100M working
6. PUFFS IRINA A PRE RI C DATA Technology Co Ltd GEPON OLT GEPON OLT FD2000S EPON Optical Fiber Access Head end Equipment Installation User Manual AS II Fir BS 388 4S 0 35 28 BR SY C DATA TECHNOLOGY CO LTD Address Flat 6 Bldg 4 South 2 of Honghualing Industrial Zone Liuxian Road Xili Town Shenzhen Guangdong China TEL 86 755 26014509 26014710 26014711 Fax 86 755 26014506 E mail Marketing cdatatec com Website www cdatatec com A ROI TRA IRA A Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual Table of Contents 1 PRODUCT INTRODUCTION eren ere rre r nnn nn nennen nnne nnne nennen nenne nennen en 3 1 1 EQUIPMENT BRIEF INTRODUCTION 3 1 2 FUNCTIONAL FEATURES eco eec enne enne enne nennen Tee n eem 3 1 3 EQUIPMENT STRUCTURE 4 1 3 1 Introduction of equipment each module mm 4 1 3 2 Equipments Component Diagram 5 1 3 3 External Interface 5 2 EQUIPMENT INSTALLATION ere rennen nnne nennen nn nnn nnne nne nnn nen nene nen 6 2 1 INSTALL
7. ase connect uplink optical SFP on OLT switch control card 2 4 2 PON Port Connection PON service card slots installs standard 1000BASE PX20 OLT SFP The OLT SFP interface is SC PC Please use the patch cord with SC PC connector to connect between the OLT and the ODN networking 2 4 3 Ground Line Connection Ensure the safety and reliable working of equipment OLT GEPON OLT FD2000S equipment should be connected with the ground if necessary Grounding screws are located in the right back side of chassis When connecting you should use screwdriver to loosen the grounding screw first then connect the ground cable finally tighten the screws 10 gee Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual 2 4 4 Management Port Connection OLT GEPON OLT FD2000S equipment provides CLI management interface marked as CONSOLE RJ45 type port and out band management internet access marked as MANAGE RJ45 type port Before starting the CONSOLE port management please use the serial cable s RJ45 port to connect the console port on OLT and the other end of DB9 port of serial cable to PC s serial console port When starting the out band management please use straight and cross Ethernet cable connecting MANAGE out band management interface to network or managed PC 3 OLT power supply and working status checkout 3 1 Check out power supply Before you connect the power supply double check the power supply if it is acco
8. h upgrade Management Interface Support in band and out band management Management Mode CLI Remote TELNET EMS Centralized Management by means of OAM protocol Reliability dual power redundant power supply power supply and fan module real time monitoring fault warning gee Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual 1 3 Equipment Structure GEPON OLT FD2000S OLT external View x Equipment Color and Appearance details are based on shipping date and order requirement 1 3 1 Introduction of equipment each module Equipment is composed by the following parts Equipment Chassis Chassis Model NO FD2000C 2U 19 inch OLT chassis You can install it in 19 standard equipment cabinet The size of chassis complies with GB T 3047 4 standard and GB T3047 8 Power Supply Module Power supply module is the power supply unit for chassis FD2000C chassis provides 2 power supply slot could install 2 power supply module It support hot plug function divided 220 110V AC and 48V DC power module gt Fan Module FD2000C chassis configured a group of 4 fans for heat dissipation and it support hot plug function gt Dust filter Module FD2000C chassis is installed with a dust filter module for filter the dust that suction casing in the air Support hot plug function available for washing gt Switch Control Module Support Model NO FD2000M Switch control module is the necessa
9. here are eight uplink ports on switch control card These ports factory setting is under Ethernet port mode Under this mode you can only use Ethernet Copper SFP on uplink slots of OLT Ethernet port mode and Optical port mode can be changed via EMS network management software configuration Eight uplink ports default settings could be changed via EMS or CLI if necessary All data retransmission of uplink ports and PON ports are based on layer two switches PON Port Configuration All default factory settings of the PON port are enabled Any PON port can be disabled by network management software Network Parameter Configuration Out Band Network Port uplink port on switch control card IP Address 192 168 120 100 Subnet Mask 255 255 255 0 Default Gateway 192 168 120 1 Read community public Write Community private In Band Network Port IP Address 192 168 1 100 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 Read community public Write Community private 13 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual Local Command Line Port CONSOLE Parameter Configuration Band Rate 9600 Data Bit 8 Parity Check NO Stop Bit 1 Flow Control NO Management Interface Default Username and Password gt Local Command Line Username admin Password admin gt SNMP Access Read Community public Write Community private 6 Appendix A Troubleshooting If you have any problem as follow
10. ing GEPON OLT FD2000S This server should install C Data s EMS network management software IP alarm address of GEPON OLT FD2000S should be the same as management server s IP address segment To receive the ONU operation alarm information and process the following key alarms on time Off alarm In order to increase reliability of system power supply we recommend you turn on double power supply When one power supply is out of working you should find out the reason and change it on time Fan abnormal alarm GEPON OLT FD2000S uses fan module which has 4 fans to loss heat 12 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual GEPON OLT should works under specified range of working temperature and humidity There is no influence if there is one fan out of work but you should find out the reason and replace it on time if there are two or more fans stop working Network management software EMS can t be logged in You should solve it out on time Network management software EMS display that PON Service Card which is installed can t be detected You should solve it on time Dust Handle Ventilation environment is good for heat dissipation of GEPON OLT You should check if the dust proof has too much dust If so you should clean it Otherwise the heat loss problem will influence the lifetime of GEPON OLT 5 Default Configuration The factory setting of GEPON OLT is as follows Up link Port Configuration T
11. ion Preparation Check out Installation environment In normal conditions OLT GEPON OLT FD2000S equipment install in the 19 inch standard equipment cabinet If there is no suitable equipment cabinet you can install it in the fixed flat surface Equipment Loading Capacity in flat surface should be larger than 20KG Around the equipment especially the two sides air vent of equipment should leave 10cm s gaa Shenzhen C Data Technolegy Ltd FD2000S OLT Installation User Manual space for ventilation Environment temperature range of equipment is 5 C 45 C Relative humidity is 109679096 And the place of equipment should keep clean Check out power supply and ground connection Before the installation you should check out if the power supply meet the demands of equipment OLT GEPON OLT FD2000S have AC and DC two kinds of power supply modes AC power supply s voltage is 220V DC power supply s voltage is 48V Please check if the condition of installation environment in line with the power supply s specification For better working about equipment it is necessary for good ground connection when install the equipment Good ground connection is the guarantee of anti lightning and anti interference Check out Supporting Facilities Before the installation of equipment you should check out if the uplink device is ready and if OLT GEPON OLT FD2000S s uplink port module in line with uplink equipment s port If you ch
12. ist white list or non authority If the authorization mode is black list please check the ONU Mac address is in the black list If it s in the black list the ONU couldn t be online Please check if the ONU MAC address is in the white list 6 Use network management to resume PON service card default setting Restart and watch if ONU can register 7 Plug out PON Service Card and restart it 7 Appendix B OLT Technical Specification 7 1 GEPON OLT System Specification Chassis FD2000C Chassis System Configuration FD2102T 2 ports PON Service Card Support Service Card FD2104T 4 ports PON Service Card 16 PRY TH Fh FL A BR Z2 RJ Shenzhen C Data Technology Lid FD20008S OLT Installation User Manual f a RITTERA RAR WIJ Shenzhen C Data Technology Lt FD2000S OLT Installation User Manual 7 2 FD2000C Chassis Specification 7 3 FD2000M Switch Control Specification 00 PRAY Th Fh FILA BR RJ Shenzhen C Data Technology Lid FD20008S OLT Installation User Manual 7 4 FD2102T PON Service Card Specification Qm BR a p sm KF Fa Fo Gr o j B n B g B BH m m g E Fer BZBM MAL Z iB F B am eda aw f ams de om sm E f am sza FA ms eee a ams i Qu C Data Technology Ltd FD2000S OLI Installation User Manual ll L7ZUUVUJA J DL UI IV UJ VIULU UI 8 Ending Thanks very much for deploying C DATA GEPON OLT equipment Should have any doubt or problem to know about our products i
13. mode is not recommended Check if net wire is OK Power Supply LED of PON Check if chassis has installed power supply module or Service Card is off not Check if PON Service Card is plugged tightly Change it to another slot In the case of normal working LNK LED light on when ONU register successfully If it light off please check it out by following steps LNK of PON Service Card is off 1 If this olt equipment works Usually it will take 40 seconds to start working after turning on 2 If there is ONU which is registered under this port 15 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual P ea watch ONU register LED 1 Check PON port working status through network management All PON ports are enabled in the case of factory fault setting 2 Use Optical Power Meter to observe if optical power s transmitting and receiving budget are in the range of OLT SFP module and ONU receiving optical power 3 Connect the ONU with other card or PON port If it can register it means there is no problem for ONU 4 Subtract other link under PON port Connect normal working ONU with PON port and see if it can register In order to avoid the optical power too strong please add attenuator or plug out a little optical fiber ONU can t register successfully connector 5 Use network management to check whether the ONU authority function is enabled Whether the authorization mode is Black l
14. n the case of default configuration the network of users could communicate with GEPON OLT FD2000S when ONU registers with GEPON OLT GEPON OLT FD2000S Connect a PC with an ONU UNI port and check if the network is running well by means of ping LAN in the same IP address or by PING package tools 3 2 3 Network Management Checkout Local Command Line Management Use the RJ45 DB9 Serial Port cable in package to link management PC with GEPON OLT FD2000S local equipment command line port CONSOLE PORT Management computer can access to OLT equipment from Super terminal interface of the PC for configuration In Band and out band Management Use PC which has installed C Data s EMS network management software to connect in band or out band port of GEPON OLT GEPON OLT FD2000S EMS network management can visit GEPON OLT GEPON OLT FD2000S after adding the olt into EMS interface The icon of GEPON OLT GEPON OLT FD2000S shows green and its PON service card is also green Icon of ONU which register to GEPON OLT GEPON OLT FD2000S is green under EMS interface as well x Please refer to relevant CLI user manual if you want to know more about command management and EMS network management configuration user manual to know more about EMS network management functions and operations 4 Daily Maintenance Please pay attention to the following key points when using GEPON OLT GEPON OLT FD2000S Monitoring Equipment Alarm There should be a server when us
15. nstallation please don t hesitate to contact us C DATA Technology Co Ltd Address Flat 6 Bldg 4 South 2 of Honghualing Industrial Zone Liuxian Road Xili Town Shenzhen Guangdong China TEL 86 755 26014509 26014710 26014711 Fax 86 755 26014506 E mail Marketing cdatatec cor Website www cdatatec com Look forward to your feedback and the long term cooperation 20
16. nto the chassis completely Now the cards panel will be parallel and level with the front panel of chassis 3 Fix the cards on the chassis with screws Please see the installation diagram of PON card and Switch control card witch control card PON Card PON Card Diagram 7 PON card and Switch control card Installation 9 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual 2 3 5 SFP Module Installation OLT GEPON OLT FD2000S equipment s switch control card uplink port and PON card s port are SFP ports SFP port is the standard interface for the common telecommunication equipment When you want to install it bring the right SFP module and insert to the relevant SFP slot directly Remark 10 100 1000M Ethernet SFP is installed in uplink slots of switch control card when the uplink device connection with OLT is UTP cable 1 25G 1310nm or 1550nm dual fiber SFP is installed in the uplink slots of switch control card when the uplink device connection with OLT is fiber 1310nm 1490nm 1 25G 20KM SFP is OLT PON SFP which is installed in the PON card slot 2 4 Cable Connection 2 4 1 Uplink SFP Service Port Based on your networking requirements switch control card s uplink SFP port can be configured as electrical module or optical module When the uplink input is UTP cable please connect uplink Ethernet SFP on olt switch control card When the uplink input is fiber ple
17. oose optical module of uplink port you should check if it is conform to optical fiber splice 2 2 Open package and checkout According to the packing list or supply contract check the model NO and quantity of equipment in line with the purchase order When you inspect the equipment please take out the equipments carefully and slightly If there is no protection of anti static avoid touching the PCB board or other electronic parts If you found the case of damaged equipment wrong or missing delivery please contact the supplier for confirmation 2 3 Installation of Each Module 2 3 1 Power supply module Installation Please take out the power supply module and push into the chassis and tightened the screws then fixed the power supply module on the frame Please see the diagram as follows Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual Power supply module Diagram 4 Power Supply Module Installation Diagram 2 3 2 Installation of Dust filter module The parts of Dust filter module will install with equipment in the factory no need users to install again After you change new one or remove to clean you need to install by yourself Dust filter module installed in the back on the right side of chassis when you install push it to the chassis gently along the guide rail than fixed by screws Please see the diagram below Dust Filter Module Diagram 5 Dust filter module Installation Diagram Dust
18. rd with the power supply requirements If each module and card are installed correctly If the equipment is in reliable grounding or not After checking everything is OK you can turn on the power switch of power supply module 3 2 Check out OLT s working status Please check if the OLT s working status from following aspects Checkthe power LED The power LED will be on if the power supply module is turned on Iffourfan module working status LED is on it means all fan functions well CRI and MAJ alarm LED should be off ifthe uplink equipment is connected correctly with uplink interface on switch control card the relevant connection LED is on PWR LED on PON Card should be on 3 2 1 Check out ONU Registration In default situation there is no need any configuration after you turn on the equipment ONU equipment can be registered after connected with the PON port of OLT GEPON OLT FD2000S Before starting access the equipment please use optical power meter to measure the optical power of PON port and check if it s in equipment specification range Using one ONU equipment correctly connecting with any PON port of OLT check if this ONU can be registered to OLT by means of the ONU s LED working status once the ONU 11 gee na prc bud FD2000S OLT Installation User Manual is successfully registered the LNK LED close to PON port of OLT should be on 3 2 2 Network Connection Checkout I
19. ry module for OLT GEPON OLT FD2000S equipment It used to communicate with the PON port service functioned as Ethernet interface s data switch and management control function of whole chassis s Switch control module installs in NMS slot of FD2000C chassis supporting hot pluggable gt PON SFP Installation on Model NO FD2102T FD2104T PON SFP used to access the EPON ONU equipment deliver the uplink and downlink 4 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual data transmission to uplink Ethernet port FD2012T PON card has two port PON SFP slots and FD2014T has four ports PON SFP slots PON SFP is installed in the 1 4 PON card slot of FD2000C chassis supporting hot plug gt Uplink SFP Uplink SFP is the optional part Switch control module s SFP is installed just according to the requirements of networking you could choose 1000BASE T electrical module or 1000BASE LX optical module PON SFP s slot should be installed with 1000BASE PX20 EPON OLT SFP 1 3 2 Equipments Component Diagram Power Supply el Fan Group Module E m A De Switch control card PON Card Diagram 1 Whole equipment structure diagram 1 3 3 External Interface gt Uplink port Slot Uplink slot is used for connection with uplink device There are 8 uplink slots which could install electric 10 100 100M SFP or 1 25G optical SFP Please see the diagram as follows Shenzhen C Data Technology
20. s please reference this table Common Problems Approach GEPON OLT can work with double power supply module It can also work when switching on single power supply module PWR A shows the working status in the upper slot of the power supply module and B shows the lower slot one Please check it out according to steps below l i 1 Observe if fans work or if there is another LED light on LED is not on after turning on l l l If fans and all LED is off it means power supply is power supply l abnormal or Power LED is damaged If it can t work please check power supply plug and power cord You should also check if it plug tightly Take two power supply modules to cross connection with power supply cord and check if there is something wrong with the power supply module Check out uplink port working mode GEPON OLT uplink SFP port support electrical port SFP module or l l optical SFP module Uplink port working mode Uplink SFP can t link with OLT l l changing need configuration with network equipment or work something management When using electric SFP module you anomaly should insert Copper SFP mode When using optical SFP module you should configure Fiber mode Ethernet SFP s working mode is 100 1000M 14 Shenzhen C Data Technology Ltd FD2000S OLT Installation User Manual auto negotiable when the uplink port working mode is Copper under EMS interface Check if net wire has quality problem R
21. system head end equipment It adopted the concept of modular design combined with the advanced industrial design and manufacturing technology providing highly reliable flexible easy for maintenance broadband access products to users EPON OLT GEPON OLT FD2000S use 2U standard chassis having 8 gigabit SFP port supported electrical module and optical module Service slot support 4 PON panels at most the whole chassis could support 16 PON ports at most It can connected 512 remote ONU maximally by1 32 splitter and1024 remote ONU mostly by 1 64 splitter EPON OLT GEPON OLT FD2000S OLT Equipment fully compliant with IEEE802 3ah standard meeting the demands of China telecom EPON equipment s interconnection and it can support hybrid networking with third party ONU OLT GEPON OLT FD2000S fully compatible with C Data s whole ONU equipment Through switching in different ONU equipment users can use FDF2000S EPON system to build various access networking such as FTTH FTTB and fiber to HFC network Providing high speed broadband access and IP integrated service 1 2 Functional Features Support 16 PON ports at most Support connected 1024 remote ONU by 1 64 splitter Support 8 uplink PON ports Layer two link rate switch MAC Address Capacity 4K VLAN supported number 4096 ONU auto detection and registration support plug and play Dynamic bandwidth allocation Support online upgrading and ONU batc