Home

4120ec User Manual - Accel Communications

image

Contents

1. OEGTOROZO ZOO FIXED WORD DISPLAY CONSOLE System Status Displays AWAY All burglary zones interior amp perimeter are armed STAY Perimeter burgiary zones such as windows amp doors are armed NSTANT erimeter burglary zones armed and entry delay is turned off BYPASS One or more burglary protection zones have been bypassed NOT READY Appears when burglary portion of the system is not ready for arming due to open protection zones The burglary portion of the system is ready to be armed Appears when AC power has been cut off Appears when AC power is present Appears when the CHIME feature is activated ALARM Appears when an intrusion has been detected and the system is armed also appears during a Fire alarm Accompanied by the protection zone ID in alarm Appears when a malfunction is discovered in the system at any time or if a fault is detected in a FIRE zone at any time or ina DAY NIGHT burglary zone during a disarmed period Accompanied by a display of zone number in trouble Appears when a fire alarm is present Accompanied by a display of the zone in alarm IMPORTANT When using the keypad to enter codes and commands sequential key depressions must be made within 3 seconds of one another If 3 READY NO AC gt seconds elapses without a key depression the entry e DISARMING THE SYSTEM AND SILENCING ALARMS FOR AWAY STAY INSTANT AND MAXIMUM ARMI
2. VISTA SERIES 4120EC SECURITY SYSTEM USER S MANUAL TABLE OF CONTENTS ENTRY EXIT DELAYS tene tentent SECURITY CODES see eerte te DUHESS CODE ee ans FUNCTIONS OF THE CONSOLE reines DISARMING THE SYSTEM AND SILENCING ALARMS ren CHIME MODE cccccccccccscssscceccecceccescescacescscsecessceuusesecsscsessecsesacsesceess CHECKING FOR OPEN ZONES cecccccescccesecscesceseseeaccscsevaceasesesavseeess BYPASSING PROTECTION ZONES eene ARMING PERIMETER ONLY STAY INSTANT ccccccccescececcesceeeseeseeeeess ARMING ALL PROTECTION AWAY MAXIMUM cere PANIG KEYS FIRE ALARM SYSTEM NATIONAL FIRE PROTECTION ASSN RECOMMENDATIONS EMERGENCY EVACUATION 0 cccccccssecssccssscccsccssccesseecscsesseseucensecseees SUMMARY OF AUDIBLE NOTIFICATIONS PROTECTION ZONES LIST eee renes QUICK GUIDE TO SYSTEM FUNCTIONS eee EMERGENCY PHONE 8 0000 UL NOTICE THIS IS A GRADE A SYSTEM INTRODUCTION Congratulations on your ownership of a VISTA Security System You ve made a chnology today Basically this system offers you three forms of protection burglary fire and emergency To realize the system s full potential it is important that you feel comfortable in operating it Your system consists of at least one Console which provides full control of system
3. Check the keypad initiated panic alarms as indicated on page 12 by pressing keys amp 4 and amp 3 If the system has been programmed for audible emergency the console will emit a loud steady alarm sound When x and are pressed ALARM and 99 will be displayed When and 3 are pressed ALARM and 96 will be displayed ALARM and or FIRE may be displayed on the consoles if a certain set of keys has been programmed for silent panic there will be no alarms or displays however a silent message will be sent to the alarm monitoring station if the system has been so connected 3 Disarm the system security code plus OFF 4 Notify the alarm monitoring station if connected to one that all tests are finished and verify results with them 13 TROUBLE CONDITIONS The word CHECK on the Console s display accompanied by a rapid beeping at the Console indicates that there is a trouble condition in the system The audible warning sound for CHECK conditions may be silenced by pressing any key TYPICAL CHECK DISPLAYS 1 display of CHECK accompanied by a 4 A display of CC indicates the control 15 wage display of one or more zone numbers indicates that a problem exists with those zone s First determine if the zone s displayed are intact and make them so if they are not if the problem has been corrected the display of the zone number s and CHECK should disappear If
4. ARMING of the FIXED WORD DISPLAY CONSOLE system without use of a security code System Status Display table on the Quick Arm if programmed to do sr next page for a list of messages that KEYS 0 9 Used to enter y might appear along with their individual security access code s meanings 10 CODE KEY Ail h try of E Allows the entry o 2 OFF KEY Disarms the burglary additional user codes that can be portion of the system silences alarms and audible trouble indicators and given to other users of the system clears visual alarm trouble after the 11 READY KEY When problem has been corrected depressed prior to arming the system the console will display all open 3 AWAY KEY Completely arms protection zones both perimeter and interior burglary protection for backup protection by 12 INSTANT KEY Arms in sensing an intruder s movements manner similar to STAY mode but through protected interior areas as well turns off the entry delay period as guarding doors windows etc Late Offering greater security while inside arrivals can enter through an entry and not expecting any late arrivals delay zone without causing an alarm if alarm will occur immediately upon the system is disarmed before the opening any perimeter protection entry delay time expires point including entry delay zones 4 STAY KEY Arms the perimeter 13 MAXIMUM KEY Arms in burgiary protection guarding doors manner similar to AWAY mode but
5. BEEPING Console only b AC POWER LOSS ALERT c MEMORY OF ALARM a ENTRY DELAY WARNING SLOW BEEPING Console only bell is used as external sounder fire alarm is pulsed ring burglary audit emergency is steady ring Loss of system battery power is not indicated or annunciated by the console warnings are for loss of AC power only 2408 PROTECTION ZONES LIST One or more sensing devices will have been assigned by the installer of your alarm system to each of the various protection zones in your system although every zone have been used For example the sensing device on your ntry Exit door may have been assigned to zone 01 sensing devices on windows in the master bedroom to zone 02 and so on ID numbers 01 08 represent sensor detector protection points ID number 96 and or 99 represent Panic alarm codes assigned by the installer For your convenience a chart has been provided which may be used to record the specific protection points that have been assigned to each zone in your system Your installer will assist you in recording this information PROTECTION POINT DESCRIPTIONS DESCRIPTION QUICK GUIDE TO ALARM SYSTEM FUNCTIONS FUNCTION PROCEDURE COMMENTS heck Zones Press x To view faulted zones when system not ready Arm System Enter code Arms system in mode Press arming key desired selected AWAY STAY INSTANT MAXIMUM Disarm
6. POWERED BY A C With Rechargeable Power Supply D TESTING Quarterly Monthly Weekly Other E SMOKE DETECTOR LOCATIONS Furnace Room Kitchen 1 Bedrooms Attic Basement Living Room DiningRoom Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Hear Door All Exterior Doors tst Floor Windows Al windows Interior Locations i All Accessible Openings Including Skylights Air Conditioners and Vents G ADDITIONAL PERTINENT INFORMATION Signature Date 21 99 Complete the reverse side of this form detach from manual and forward to your homeowner s insurance carrier for possible premium credit GLOSSARY The following glossary of terms are used throughout the manual AM DISARM Armed simply means that the burglary portion of your system is turned ON and is in a state of readiness Disarmed means that the burglary system is turned OFF and must be rearmed to become operational However even in a disarmed state emergency and lire portions of your system are still operational KEYPAD This is the area on your Console containing numbered pushbuttons similar to those on telephones or calculators These keys control the arming or disarming of the system and perform other functions which were previously described in this manual ZONE A specific area of protection BYPASS To disarm a specific area
7. closed or partly open doors if warning devices sound on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedrooms Even persons who are awake may not hear the warning if the alarm is muffled from a stereo radio air conditioner or other appliance or by passing traffic Finally alarm warning devices however loud may not warn hearing impaired people waken deep sleepers Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service Telephone lines are also subject to compromise by sophisticated intruders Even if the system responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not respond appropriately This equipment like other electrical devices is subject to component failure Even though this equipment is designed to last as long as 10 years the electronic components could fail at any time The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance This alarm system should be tested weekly to make sure all sensors and transmitters are working properly Installing an alarm system may make one eligible for lower insurance rates but an alarm system is not a substitute for insuran
8. operation various sensors which provide perimeter and interior burglary protection plus a selected number of strategically placed smoke or combustion detectors designed to provide early warning in case of fire decision in choosing it for it represents the latest in security protection The system uses microcomputer technology to monitor all protection zones and system status and provides appropriate information for display on the Console s used with the system and initiates appropriate alarms When programmed to do so the system can also transmit appropriate alarm or status messages over the phone lines to a central alarm monitoring station THE DISPLAY CONSOLES feature a multifunction 12 key digital keypad and uses a fixed word English language zone numeric LCD display which displays the nature and location of all occurrences The consoles also have a built in sounder There are two fixed word consoles available The 4137 features backlit keys while the 4127 features a compact design its keys are not backlit FIRE amp BURGLARY PROTECTION One or more sensing devices will have been assigned by the installer of your alarm system to each of the various protection zones in your system although not every zone may have been used For example the sensing device on your Entry Exit door may have been assigned to zone 01 sensing devices on windows in the master bedroom to zone 02 and so on These numbers
9. responding to smoke or heat producing objects in their vicinity Should this be the case eliminate the source of heat or smoke If this does not remedy the problem there may still be smoke in the detector Clear it by fanning the detector for about 30 seconds When the problem has been corrected clear the display by entering your code and pressing the OFF key 15 NATIONAL FIRE PROTECTION ASSN RECOMMENDATIONS ON SMOKE DETECTORS With regard to the number and placement of smoke heat detectors we to the recommendations contained in the National Fire Protection Association s Standard 74 noted below Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition it is recommended that the householder consider the use of heat or smoke detectors in the living room dining room bedroom s kitchen hallway s attic furnace room utility and storage rooms basements and attached garages CONSOLE PLACE DETECTOR NEAR ALL SLEEPING AREAS SMOKE O DETECTOR PLACEMENT MAXIMUM FLOOR BEST RESIDENTIAL DETECTOR PLACEMENT pe BETWEEN
10. windows and other perimeter protection eliminates the entry delay period thus points and sounds an alarm if one is providing maximum protection An opened Interior protection is not alarm will occur immediately upon armed which allows movement within Opening any protection point your house without causing an alarm including entry delay zones Late arrivals can enter through an 14 POWER INDICATOR entry delay zone without causing an GREEN Lit when primary power is alarm if the system IS disarmed before on If off system is operating on its the entry delay time expires backup battery power CALL YOUR 5 TEST KEY Tests the alarm INSTALLER IMMEDIATELY sounder if disarmed Refer to the 15 ARMED INDICATOR RED TESTING THE SYSTEM section for Lit when the system has been armed test procedures STAY AWAY INSTANT or 6 BYPASS KEY Removes MAXIMUM individual protection zones from being 16 INTERNAL SOUNDER monitored by the system Displays Source of audible internal warning and previously bypassed protection zones confirmation sounds as well as 7 CHIME KEY Turns on amp off the alarms see Summary of Audible CHIME mode When on any entry Notifications through a delay or perimeter zone while the system is disarmed will cause a tone to sound at the Console s away AC MAXMSUNM rest BYPASS aa NS BAT QUART TA FIRE REAOY WES TAMT CODE Chee 7 READY 22 rs Mo Ce
11. BEDROOMS AND REST OF HOUSE Oe OF STAIRWELLS 16 EMERGENCY EVACUATION Establish and regularly practice a plan of escape in the event of fire The following steps are recommended by the National Fire Protection Association rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room EXAMPLES KITCHEN BACK a DOOR 1 FLOOR D FRONT Plan on your detector or your 4 Assure that all bedroom doors are interior and or exterior sounders shut while you are asleep This will warning all occupants prevent deadly smoke from Determine two means of escape entering while you escape from each room One path of 5 Try the door If the door is hot escape should lead to the door check your alternate escape that permits normal exit from the route If the door is cool open it building The other may be a cautiously Be prepared to slam window should your path be the door if smoke or heat rushes unpassable Station an escape in ladder at such windows if there isa 6 Crawl in the smoke and hold your long drop to the ground breath Sketch a floor plan of the building 7 Escape quickly don t panic Show windows doors stairs and 8 Establish a common meeting place outdoors away from your house where everyone can meet and then take steps to contact the authorities and account for those missing Choo
12. IABILITY FOR AN PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty gives you specific legal rights and you may also have other rights which vary from state to state No increase or alteration written or verbal to this warranty is authorized e ALARM DEVICE MANUFACTURING CO ADEMCO Rony wc 165 Eileen Way Syosset New York 11791 4861 4 9 92 Copyright 1990 PITTWAY CORPORATION
13. ION WITH THIS PRODUCT INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE ANY ACTION FOR BREACH OF ANY WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY MUST BE BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE IN NO CASE SHALL SELLEH BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not represent that the product may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guaran tee that such will not occur or that there will be no personal injury or property Ic as a result CONSEQUENTLY SELLER SHALL HAVE NO L
14. NG PROCEDURE 1 Enter security code and press OFF 1 The READY message will be displayed and the console will beep once to confirm that the system is disarmed unless an alarm has occurred 2 If an alarm has occurred note the zone number displayed and repeat step 1 to restore the READY message display If the message will not display go to the displayed protection zone and remedy the fault close windows etc If the fault cannot be remedied notify the alarm agency CHIME MODE RESULT Any alarm sounders will be silence ALARM and zone number w displayed will clear only when the open sensor is closed A fire alarm is indicated by a display of both FIRE and the zone number on the Console These will clear only when the fire zone is again intact See SUMMARY OF AUDIBLE NOTIFICATION section for information which will enable you to distinguish between FIRE and BURGLARY alarm sounds ENTER CODE amp PRESS OFF THIS FEATURE IS FUNCTIONAL ONLY WHEN THE SYSTEM IS DISARMED Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode When activated three tones will sound at the Console whenever a door or window is opened and the Not Ready message will be displayed Pressing the READY key will display the open zone number Note that Chime mode can be activated only when the system is Disarmed To turn Chime Mode on enter the security co
15. System Enter code Disarms system and Press OFF 1 silences alarms Enter code Press BYPASS 6 Enter zone numbers to be Bypass zones bypassed use 2 digit entries Chime Mode Enter code Console will sound if doors Press CHIME 9 or windows are violated while system disarmed Enter code amp press TEST 5 Sounds alarm sounder 19 Bypassed zones are unprotected and will not cause an alarm if violated Emergency Phone Numbers Alarm Monitoring Station Fire Department Police Gas Electric Company Neighbor Doctor Hospital Ambulance Emergency SERVICING INFORMATION Your local authorized service representative is the person best qualifi to service your alarm system Arranging some kind of regular program him is advisable Your local service representative is 20 OWNER NSURAN 5B UN CREDIT REQUEST fn LA gh PP PT EE EE EE E E E E E Rs eS l This form should be completed and forwarded to your homeowner s insurance arrier for possible premium credit GENERAL INFORMATION Insured s Name and Address Insurance Company Policy No ADEMCO s VISTA 4120EC Type of Alarm Burglary Fire Both Installed by Serviced by name name address address B NOTIFIES Insert B Burglary F Fire Local Sounding Device Police Dept E Fire Central Station Name and Address C
16. ack We recommend that your certified installer demonstrate disconnecting the phones on installation of the system Do not disconnect the phone connection inside the control communicator Doing so will result in the loss of your phone lines If the regular phone works correctly after the control communicator has been disconnected from the phone lines the control communicator has a problem and should be returned for repair If upon disconnection of the control communicator there is still a problem on the line notity the telephone company that they have a problem and request prompt repair service The user may not under any circumstances in or out of warranty attempt any service or repairs to the system must be returned to the factory or an authorized service agency for all repairs 25 WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system it does not of guaranteed protection against burglary or fire or other emergency Any ala system whether commercial or residential is subject to compromise or failure to warn for a variety of reasons For example e Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device Intrusion detectors e g passive infrared detectors smoke detectors and many other sensing devices will not work without power Battery operated devices will not work witho
17. at detectors will automatically send signals to your Control Communicator wering a loud interrupted sound from the Console An interrupted sound will be produced by optional exterior sounders A FIRE message will appear at your Console and remain on until you silence the alarm IN CASE OF FIRE ALARM 1 Should you become aware of a fire emergency before your detectors sense the problem go to your nearest Console and manually initiate an alarm by pressing the panic key pair assigned as FIRE emergency if programmed by the installer and hold down for at least 2 seconds 2 Evacuate all occupants from the premises 3 If flames and or smoke are present leave the premises and notify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone descriptor of the zone s in an alarm condition will be displayed at the Console Note Approval of the panel s burglar alarm functions does not fall within the California State Fire Marshal s area of jurisdiction E t vg NOT READY ARMEO FOWER SILENCING A FIRE ALARM 1 Silence the alarm by entering your code and pressing the OFF key To clear the display enter your code and press the OFF key again If the Console does not indicate a READY condition after the second OFF sequence press the READY key to display the zone s that are faulted Be sure to check that smoke detectors are
18. ate an alarm if the system is not disarmed within the entry delay period MAXIMUM KEY RESULT Arms all perimeter and interior sensors with entry delay off You may exit during the exit delay period BUT alarms will trigger instantly upon reentering or when any protection point interior or exterior is violated This mode is suggested when the premises will be vacant for extended periods of time such as vacations etc or when retiring for the night and no one will be moving through protected interior areas 11 PANIC KEYS FOR MANUALLY ACTIVATING SILENT AND OR AUDIBLE ALARMS There are two possible combinations of paired keys that are installer programmable emergency functions See your installer for the functions that have been programmed for these emergency key pairs Typical functions that might be programmed are Silent Police Audible Police Personal Emergency and Fire To use a Panic function simply press both keys of the assigned pair at the same time and hold down for at least two seconds Active Panic Functions KEY x 47 displayed as zone 99 KEY 3 displayed as zone 96 Oanueo powtn 12 RESULT If programmed for silent emergency tk your installer and the system connected to a central alarm monitoring station the control will send a silent alarm signal to the central station but there will be no audible alarms or visual displays if programmed for audible eme
19. by carelessness and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circu children playing with matches or arson Depending upon the nature of the and or the locations of the smoke detectors the detector even if it operates as anticipated may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their detection ability Passive Infrared Detectors sense changes in temperature however as the ambient temperature of protected area approaches the temperature range of 90 to 150 F the detection performance can decrease 26 WARNING THE LIMITATIONS OF THIS ALARM SYSTEM continued Alarm warning devices such as sirens bells or horns may not alert people or wake up sleepers if they are located on the other side of
20. ce Homeowners property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property We continue to develop new and improved protection devices Users of alarm systems owe it to themselves and their loved ones to learn about these developments 27 ADEMCO ONE YEAR LIMITED WARRANTY Alarm Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its security equipment the product to be free from defects in materials and workmanship for one year from date of original purchase under normal use and service Seller s obligation is limited to repairin or replacing at its option free of charge for parts labor or transportation product proven to be defective in materials or workmanship under normal use a service Seller shall have no obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than the Seller In case of defect contact the security professional who installed and maintains your security equipment or the Seller for product repair This one year Limited Warranty is in lieu of all other express warranties obligations or liabilities THERE ARE NO EXPRESS WARRANTIES WHICH EXTEND BEYOND THE FACE HEREOF ANY IMPLIED WARRANTIES OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECT
21. cur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e f using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the receiver away from the control communicator Move the antenna leads away from any wire runs to the control communicator Plug the control communicator into a different outlet so that it and the receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless thorized by the Installation Instructions or User s Manual Unauthorized anges or modifications could void the user s authority to operate the equipment IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems disconnect the control by removing the plug from the RJ31X CA38A in Canada wall j
22. d zones to be sequentially displayed before arming 1 Enter security code and press 4 The BYPASS message will be BYPASS 6 displayed indicating the presence 2 Wait for all bypassed zones to be of one or more bypassed zones sequentially displayed 5 Arm the system as usual LIMITATIONS Bypassed zones are unprotected Fire or emergency zones cannot and will not cause an alarm when be bypassed violated while system is armed e Arming the system before bypassed zones are displayed nullifies all bypasses ARMING PERIMETER ONLY STAY STAYING HOME EXPECTING LATE ARRIVALS INSTANT STAYING HOME NO LATE ARRIVALS EXPECTED PROCEDURE 1 Enter the security code when the READY message is displayed 2 Press the STAY 3 or INSTANT 7 key depending on arming mode desired 3 The armed state message will Ba displayed accompanied by three beeps from the Console Exit delay begins Perimeter protection is in effect immediately except entry delay zone if STAY key is pressed STAY KEY RESULT Arms sensors guarding doors and windows with entry delay on Late arrivals can enter through the entry delay zone door and disarm the system within the entry delay period without Causing an alarm See your installer for actual delay times set for your system Alarms will occur instantly when any exterior protection point is violated except the entry delay zone door which will activate an alarm if the system is not disarmed w
23. de and press the CHIME 9 key The CHIME message will appear To turn Chime Mode off enter the security code and press the CHIME 9 key again The CHIME message will disappear ENTER CODE amp PRESS CHIME CHECKING FOR OPEN ZONES BEFORE ARMING YOUR SYSTEM ALL PROTECTED DOORS WINDOWS AND OTHER PROTECTION ZONES MUST BE CLOSED PROCEDURE the NOT READY message is displayed prior to arming check for open zones by depressing and releasing the READY key do not enter code first 2 All open protection points will be displayed These points must be either closed or bypassed before the system can be armed The READY message will be displayed when all protection zones have been either closed or bypassed BYPASSING PROTECTION ZONES FOR ARMING WITH ONE OR MORE ZONES SELECTIVELY UNPROTECTED PROCEDURE NOTES 1 System must be disarmed first 1 All bypasses are removed when an Enter security code OFF sequence security code plus 2 Press BYPASS 6 and enter zone OFF is performed number s of zones to be bypassed 2 Temporary users should not be e g 01 02 03 etc shown how to bypass protection Important All single digit zone points unless they have a need to numbers must be preceded by a Know zero example enter 01 for zone 1 DISPLAYING BYPASSED ZONES 3 When finished entering all zone For determining what zones have numbers to be bypassed wait for bsen previously bypassed bypasse
24. e Cette pr caution est particuli rement importante dans les r gions rurales Avertissement L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recours un service d inspection des installations lectriques ou un lectrician selon le cas L indice de charge IC assign chaque dispositif terminal pour viter toute surcharge indique le pourcentage de la charge totale qui peut tre raccorde un circuit t l phonique boucl utilis par ce dispositif La terminaison du circuit boucl peut tre constitu e de n importe quelle combinaison de dispositifs pourvu que la somme des indices de charge de l ensemble des dispositifs ne d passe pas 100 24 FEDERAL COMMUNICATIONS COMMISSION FCC STATEMENT is equipment has been tested to FCC requirements and has been found ucceptabie for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not oc
25. ion de l utilisateur Avant d installer ce mat riel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de t l communication Le mat riel doit galement tre install en suivant une m thod accept e de raccordement Dans certains cas les fils int rieurs de l entreprise utilis s pour un service individuel a ligne unique peuvent tre prolong s au moyen d un dispositif homologu de raccordement cordon prolongateur t l phonique interne L abonne ne doit pas oublier qu il est possible que la conformit aux conditions nonc es ci dessus n emp chent pas la d gradation service par certaines situations Actuellement les enterprises de t l communication ne permet pas que l on raccorde leur mat riel aux jacks d abonn s sauf dans les cas precis pr vus par les amp particuliers de ces entreprises Les r parations de mat riel homologu doivent tre effectu es pas un centre d entretien canadien authoris d sign par le fournisseur La compagnie de t l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Pour sa propre protection l utilisateur doit s assurer que tous les fils de mise la terre de la source d energie lectrique des lignes t l phoniques et des canalisations d eau m talliques s il y en a sont raccord s ensembl
26. ithin the entry delay period Interior protection points are disarmed to permit freedom of movement throughout the interior _ 10 INSTANT KEY RESULT Arms sensors guarding doors windows with entry delay off Alarms will occur instantly when any exterior protection point is violated including the entry delay zone door Interior protection points are disarmed to permit freedom of movement throughout the interior ARMING ALL PROTECTION AWAY NO ONE STAYING HOME MAXIMUM NO ONE STAYING HOME MAXIMUM SECURITY PROCEDURE _ Enter the security code when the HEADY message is displayed 2 Press the AWAY 2 or MAXIMUM 4 key depending on arming mode desired 3 The armed state message will be displayed accompanied by two beeps from the Console Exit delay begins if programmed a slow beeping will sound throughout the exit delay period Complete system protection is in effect immediately except entry delay zone if AWAY key is pressed AWAY KEY RESULT Arms all perimeter and interior sensors with entry delay on You may exit during the exit delay period and reenter through the entry delay zone door and disarm the system within the entry delay period without causing an alarm See your installer for actual delay times set for your system Alarms will occur instantly when any protection point interior or exterior is violated except the entry delay zone door if AWAY key pressed which will activ
27. not key an OFF sequence Code plus OFF to clear the display If the display persists CALL FOR SERVICE IMMEDIATELY display of FC at the Console indicates that a failure has occurred in the telephone communication portion of your system CALL FOR SERVICE IMMEDIATELY A display of OC indicates an open connection from the console to the control CALL FOR SERVICE IMMEDIATELY in communication with a remote station Effectively the control is disabled during this time Note that all alarms and troubles will be restored and annunciated when the system is retumed to normal POWER FAILURE If the POWER indicator is off operating power for the system has stopped and is inoperative CALL FOR SERVICE IMMEDIATELY If the POWER indicator is on but the message NO AC is displayed the Console is operating on battery power only If only some lights are out on the premises check circuit breakers and fuses and reset or replace as necessary CALL FOR SERVICE IMMEDIATELY if AC power cannot be restored SERVICING INFORMATION Your local authorized service representative is the person best qualified to service your alarm system Arranging some kind of regular program with him is advisable Your local service representative is 14 FIRE ALARM SYSTEM IF INSTALLED Your fire alarm system if installed is on 24 hours a day for continuous protection In the event of an emergency the strategically located smoke and he
28. of burglary protection while leaving other areas armed DELAY ZONE An area of protection containing doors most frequently used to enter or exit typically a front door back door or door from the garage into the building The delay zone allows sufficient time for authorized entry or exit without causing an alarm Consult your installer for the entry and exit delay times that have been set for your system during installation DAY NIGHT ZONE An area of protection whose violation causes a trouble indication during the disarmed DAY mode and an alarm during the armed NIGHT mode 23 CANADIAN DEPARTMENT OF COMMUNICATIONS DOC STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment This certifica means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilites of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of certified connector assembly telephone extension cord The customer should be aware that compliance with the above conditions may not prevent degrada
29. rgency by your installer a loud steady alarm will sound at your console and at any external sounders that may be connected A personal emergency alarm will notify the central station if connected and will sound at consoles but not at external bells or sirens A fire alarm will send a fire alarm message to the central station and will uniquely sound external bells and sirens PRESS BOTH AT SAME TIME TESTING THE SYSTEM TO BE CONDUCTED WEEKLY 1 Disarm the system Enter security code and press the TEST 5 key 3 The external sounder should sound for 3 seconds and then turn off If the sounder does not sound it may be due to dialer communication activity Wait a few minutes and try again If the sounder still does not sound CALL FOR SERVICE IMMEDIATELY 4 Turn the Test mode off by entering the security code and preesing OFF ARMED SYSTEM TEST Important A message will be sent to the central alarm monitoring station if the system is so connected during the following tests Notify them that a test will be in progress Note A display of FC on your console indicates a failure of the system to communicate with the alarm monitoring station 1 Arm the system and fault each zone open and close each protected doors or window Silence the alarm sounder s each time by entering your security code and pressing OFF Check that Entry Exit delay zones provide the assigned delay times see page 4 2
30. se someone to assure that nobody returns to the house many die going back 17 SUMMARY OF AUDIBLE NOTIFICATION SOUND CAUSE DISPLAY LOUD INTERRUPTED FIRE ALARM FIRE and ALARM is displayed Console amp External protection zone in alarm is displayed LOUD CONTINUOUS BURGLARY AUDIBLE ALARM is displayed protection zone Console amp External EMERGENCY ALARM in alarm is also displayed ONE SHORT BEEP a SYSTEM DISARM a Only READY is displayed not repeated b SYSTEM ARMING b NOT READY is displayed open Console only 2 protection zone number is displayed c BYPASS VERIFY c The bypassed protection zone numbers are displayed One beep for each number displayed BYPASS displayed TWO SHORT BEEPS ARM AWAY OR AWAY and possibly INSTANT are MAXIMUM displayed THREE SHORT a ARMSTAY OR a STAY and possibly INSTANT are BEEPS INSTANT displayed Console only b ZONE OPENED b CHIME displayed open protection WHILE SYSTEM IS zone number is displayed IN CHIME MODE c ENTRY WARNING a TROUBLE c No display a CHECK displayed Troubled protection zone is displayed b NO AC displayed may alternate with other displays that may be present c FIRE and or ALARM is displayed zone in alarm is displayed a None during delay Exceeding the delay time without disarming causes alarm RAPID
31. so recommended that obvious codes such as 1111 or 1234 not be assigned DURESS CODE QUICK ARMING Note that if Quick Arming was programmed by the installer the key can be pressed in place of the security code when arming the system The security code is always required when disarming the system To Assign or delete Temporary Codes 1 Enter Master code 2 Press CODE 8 key 3 Enter User Number to be assigned or deleted 3 8 4 To assign a code enter temporary code for that User Number To delete a code enter Master Code for that User Number 5 The Console will beep once when procedure has been completed successfully WHEN FORCED TO DISARM ARM UNDER THREAT Enter the first three digits of the security code Increase the final digit by one and then press OFF or AWAY etc if arming the system The system will disarm or arm but can silently notify the central station of your situation if that service has been provided For example if the Normal security code is 1 2 3 4 the Duress security code is 1235 IMPORTANT e This code is useful only when connected to a central station Duress code capability is present for codes ending in 9 Users of temporary codes must be instructed to enter their codes carefully to avoid the possibility of accidentally entering the Duress code ELT FUNCTIONS OF THE CONSOLE 1 DISPLAY WINDOW Refer to the 8 4 KEY Permits
32. tion of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution User should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate The Load Number LN assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100 AVIS L tiquette du ministr re des Communications du Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonctionnera la satisfact
33. ur system provides four modes of burglary protection STAY AWAY INSTANT and MAXIMUM and even allows you to BYPASS selected zones of protection while leaving the rest of the system armed The system also provides a CHIME mode for alerting users to the opening and closing of doors and windows while the system is disarmed Refer to the other sections of this manual for procedures for using these features seconds seconds Delays may be from 15 to 225 seconds in non UL installations but no more than 60 seconds for Ex delay or 45 seconds for Entry delay for a UL Listed Household burglary application Exit Delay Entry Delay SECURITY CODES At the time of installation your installer programs a personal four digit code known only to you and yours This code must be entered when performing most system functions including arming and disarming of the system As an additional safety feature up to 6 temporary codes can be assigned for use by those not having a need to know the master code Temporary codes are assigned single digit User numbers from 3 to 8 Before assigning a temporary code though be sure it does not conflict with the DURESS code see DURESS CODE section Note that the master code remains in effect even when a temporary code is assigned NOTE Users to whom temporary codes have been assigned should not be shown how to bypass protection points unless they have a need to know It is al
34. ut batteries with dead batteries or if the batteries are not put in properly Devices powered solely by AC will not work if their AC power supply is cut off for any reason however briefly Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver Even if the signal path has been recently checked during a weekly test blockage can occur if a metal object is moved into the path user may not be able to reach a panic or emergency button quickly enough While smoke detectors have played a key role in reducing residential fire deaths in the United States they may not activate or provide early warning for a variety of reasons in as many as 35 of all fires according to data published by the Federal Emergency Management Agency Some of the reasons smoke detectors used in conjunction with this System may not work are as follows Smoke detectors may have been improperly installed and positioned Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors also may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basement fire Moreover smoke detectors have sensing limitations No smoke detector can sense every kind of fire every time In general detectors may not always warn about fires caused
35. will appear on the display when the respective zone is faulted The fire protection portion of your security system if used is always on and will sound an alarm if a fire condition is detected Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection smoke detectors and planning emergency exit routes from your house ENTRY EXIT DELAYS Your system was programmed by the installer with a preset entry delay time during which the system must be disarmed upon entering or an alarm will occur This feature allows you to reenter through the entry delay door without setting off the alarm A slow beeping will sound at the console to remind you to disarm the system The entry delay feature can also be turned off for greater security when sleeping or while away for extended periods of time INSTANT amp MAXIMUM modes A preset exit delay was also programmed to allow you time to leave the premises without setting off the alarm after arming the system See your installer for your delay times The burglary protection portion of your system must be armed before it will sense burglary alarm condition When an alarm occurs both th console and external sounders will sound and a message in the Display Window will identify the zone s causing the alarm In addition if your system is connected to a central monitoring station an alarm report will be sent Disarming the system will stop alarm sounding Yo

Download Pdf Manuals

image

Related Search

Related Contents

GSM Temperature & Humidity monitor and alarm device manual  Manual do Proprietário CG125 Cargo KS • ESD  Mise en page 1 - Opéra de Lille  

Copyright © All rights reserved.
Failed to retrieve file