1. voltage current limits are 30 V5 max 200 mA max Quadrature Pulse Output Qx Two Hall Effect sensors are arranged to give separate outputs out of phase with one another The Quadrature output is commonly used to provide verification of output signal integrity or to measure bi directional flow in conjunction with an appropriate discriminator circuit or display The power supply requirement is 8 24 Vbo 20 mA max NPN Inductive Pick up Ex Inductive pick up with non magnetic rotor for applications with high ferrous content liquids The signal output is 3 wire NPN transistor The power supply requirement is 5 24 Vpg 20 mA max No responsibility taken for errors subject to change without prior notice Ko Electronic Options with LCD Display O wa a a a m Dual Rate Rate Batch Function Totalizer Totalizer Totalizer Controller Power Source External Required for E 8 24 Voe 8 24Vpe 8 24Vbo 12 24 Voc Output Backlighting LCD Display Line 1 no of Digits 7 5 an ance 17 mm 6 yes Decimal Point yes Subscripts Displayed yes Accumulated Total es y y y Resettable Total y Linearization O lt Rate Display J s ve e ve 0 e o o e n n n yes yes yes yes no yes Backlighting yes no Input Type 20m 200 High Low Flow Output Batch End amp Control NPN PNP 5 yes no no Pulse Output NPN PNP 2 x SPDT Relays optional Cable Entrie
2. Cable Z1 Dual DOR 52 Options Q4 2x NPN OC 150 Cable Totalizer 2x NPN OC Terminal Box on Stem Kit Z3 Rate Dual N9 2 NPT Totalizer _ Dina Qi Male E1 Non magnetic Rotor for p o Ferrous Media NPN sa B Pug 10 Cable otalizer Non magnetic Rotor for Ferrous Media NPN R9 R2 Male 30 Cable Non magnetic Rotor for Ferrous Media NPN 60 Cable Non magnetic Rotor for Ferrous Media NPN 150 Cable Non magnetic Rotor for Ferrous Media NPN Terminal Box on Stem Kit Only available with PEEK rotor and sealing material F No responsibility taken for errors subject to change without prior notice Insertion Paddle Wheel Flow Meter Monitor Model DOR Process Temperature Limits with Rotor and Output Options Max Media Through Valve Installation for DOR 52 series Temperature PVDF 212 F PEEK 300 F Output Type E1 E4 185 F F1 F4 R1 R4 212 F 260 F Q1 Q4 F5 F6 R5 260 F Model DOR 52 Must use PEEK rotor for all Output options with media temperatures gt 212 F Additionally be sure Ball or gate valve _ female 2 NPT or R2 connection to select an appropriate seal material suitable for NOTE Mini both media compatibility and the maximum media al temperature internal diameter to be 44 0 mm 2 NPT or R2 Typical DOR Installation Nipple Female 2 NPT or R2 Threadolet NOTE Minimum internal diameter to be 44 0 mm ened b l oe
3. s ia a pe a t Insertion Depth 1 8 of Pipe Inner Diameter E E E L4 DOR Upstream Downstream Straight Piping Requirements Major obstructions such as pumps valves reducers or strainers must be kept well outside of the required straight run pipe sections 10 pipe dia Minimum 5 pipe dia Minimum 25 pipe dia Preferred 10 pipe dia Preferred Eoo o l a S FLOW Meer a n No responsibility taken for errors subject to change without prior notice Insertion Paddle Wheel Flow Meter Monitor Model DOR Dimensions mm TERMINAL BOX 91 L A 12 or 2 NPT R2 2 NPT R2 a ai 13 OA Z3 B1 All dimensions in mm 2 mm No responsibility taken for errors subject to change without prior notice
4. that allows insertion of the rotor to a precise depth in the pipe for optimal readings Available signal outputs include NPN open collector frequency and or reed contact frequency or millivolt frequency Optional indicators include battery powered totalizers and loop powered rate meter totalizers with outputs and batch controllers The DOR 5 may be installed through a 2 ball valve to allow serviceability with minimal process interruption With its symmetrical design the DOR may also be used for bi directional flow measurement when fitted with the quadrature output option in conjunction with an appropriate discriminator circuit or display Applications e HVAC Hot and Cold Water Fire Systems and Thermal Energy Monitoring e Municipal Water Distribution Water Management and Water Treatment e Irrigation Water Management e Water Treatment Chlorination Desalination and Mechanical Filtration Plants Chemical Injection Systems Refineries Fire and Cooling Systems e Power Generation Boiler Feed Water Steam Condensate Process Water and Water Balancing e Chemical Process amp Cooling Tower Water Chemical and Water Batching e Others Cement Manufacturing Flow Testing Fire Truck and Hydrant Flow Monitoring Food Processing Pulo Paper Mining and Fountains Technical Details Velocity Range Linear 1 0 38 ft s 1 5 w Well Established Flow Profile 1 off s at Factory Conditions and Optimal Straight Runs 116
5. 0 PSI 5 212 F Standard See Max Allowable Media Temperature Table for Other Options and Restrictions Linearity Repeatability Max Pressure Temperature Range Insertion Paddle Wheel Flow Meter Monitor Model DOR Materials Body Rotor Rotor Shaft Bearing Seals Electronics Max Frequency Supply Voltage Electronic Features Wiring Standard Transmission Distance Cable Entry Terminal Box Ingress Protection Straight Piping Requirement Weight Approx 316L Stainless Steel PVDF or PEEK Depending on Model 316L Stainless Steel Graphite PTFE FKM Standard 5 300 F EPR Ethylene Propylene Rubber 40 260 F NBR Nitrile 40 260 F 220 240 Hz Hall Effect and Voltage Output 73 80 Hz Reed Switch Output See Electronics Comparison Table See Electronics Comparison Table 10 Ft 5 wire Shielded Cable 3000 ft Maximum without Integrated Electronics Standard M20x1 5 Optional 1 2 NPT via Adapter IP 66 67 IP 68 w Cable Connection Minimum 10xd Upstream 5xd Downstream Optimal 25xd Upstream 10xd Downstream 3 6 Ib DOR 4 5 5 Ib DOR 5 without Electronics No responsibility taken for errors subject to change without prior notice Insertion Paddle Wheel Flow Meter Monitor Model DOR Electrical Output Specifications Hall Effect Sensor Output Fx Nx Qx The Hall Effect Sensor is a high resolution solid state
6. 03 2 2015 measuring Insertion Paddle Wheel Flow Meter Monitor for Low Viscosity Liquids J monitoring J analyzing e Flow Range Soe 180 GPM to 25 000 800 000 GPM e Flow Velocity Range 1 0 33 0 ft s Paa 1160 PSI e t 300 F e Connection 1 NPT 2 NPT Male R 1 amp R 2 Male for Pipe Sizes 11 2 100 e Linearity 1 5 with Well Established Flow Profile e Body Material Stainless Steel e Outputs Pulse LCD Display Batching Totalizing 4 20mA Switches Order from C A Briggs Company 632 Davisville Road Willow Grove PA 19090 Phone 215 784 9250 Fax 215 784 0611 E Mail Sales cabriggs com www cabrigqgs com Ko Description The DOR series insertion paddle wheel flow sensor offers cost effective measurement of the flow of water or water like liquids in large pipes The sensor is inserted into the process piping via a suitable tee thread o let or half coupling Flow through the pipe results in rotation of the paddle wheel which is proportional to the flow velocity and to the flowrate in the pipe The DOR is much less expensive than full bore flowmeters especially in larger pipe sizes Insertion paddle wheel sensors are rugged and boast exceptional tolerance to dirt and solids The DOR features an all 316 L stainless steel body The rotor is made of PVDF or PEEK with a long life graphite PTFE self lubricating bearing It has an integral precision insertion mechanism
7. 3 wire device providing an unsourced open collector NPN transistor output The term unsourced means that no voltage is applied to the output from within the flowmeter It must be pulled to a high or on state by 5 24V supplied from an external source typically the receiving instrument The pulse output between signal and OV is a voltage square wave with the high level being the DC voltage available at the open collector and the low level being OV The receiving instrument must incorporate a pull up resistor typically greater than 10kQ which ties the open collector to the available DC voltage level when the Hall sensor is not energized When energized the open collector output is pulled to ground through the emitter OV The power supply requirement is 5 24 Voc 20 MA max Voltage Pulse Output Fx A self generating 2 wire voltage pulse output with 1 5V voltage spike of approximately 10 microseconds duration is generated with no dependence on rotor speed Reed Switch Pulse Output Rx The reed switch output is a two wire normally open SPST voltage free contact ideal for installations without power or for use in hazardous area locations simple apparatus when Intrinsically Safe I S philosophy is adopted When using the reed switch output the liquid temperature must not change at a rate greater than 18 F per minute In general the reed switch life will exceed 2 billion actuations when switching less than 5V at 10mA The
8. s 3 x Yo NPT 3 x Y2 NPT Intrinsic Safe Option upon req no Optional Wall pipe or panel mounting Ambient Temperature 4 176 F non condensing Replaces solid state outputs consult factory for availability DOR Series Nominal Flow Measuring Ranges Sch 40 Steel Pipe 1 33 ft s Fluid Velocity Line Size Neue Line Size NOVA Measuring Measuring Sch 40 Steel Range apm Sch 40 Steel Range GPM 1 1 2 6 210 245 8 080 K Insertion Paddle Wheel Flow Meter Monitor Model DOR Order Details Example DOR 42 2 F N8 F6 Z3 Sealing Mechanical Output Rotor Shaft Material Connection Electrical Connection Electronics DOR 42 Options F1 NPN OC 1 5V Pulse 10 Cable Standard NPN OC 1 5V Pulse wN8 1 NPT 30 Cable Male oe ie NPN OC 1 5V Pulse 60 Cable NPN OC 1 5V Pulse 2 NPT 150 Cable Male sa Dac NPN OC 1 5V Pulse Terminal Box on Stem Kit NPN OC 1 5V Pulse R1i Integral Electronic on 0O Frequency Male Stem Kit Output NPN OC Terminal Box Only on Stem kit High Temp Sensor Reed Switch 10 Cable Reed Switch 30 Cable Reed Switch 60 Cable Only for Output Reed Switch 150 Cable F6 Reed Switch Terminal Box on Stem Kit _ B1 Batch Pipe Size i eo ow R2 Male F FKM PVDF SS Standard Max 212 F E EPR A PEEK SS Q1 2x NPN OC 10 Cable ontroller Max 300 F Q2 2x NPN OC 30 Cable NBR Q3 2x NPN OC 60

Download Pdf Manuals

image

Related Search

Related Contents

PDF - Boise State University  Précocité intellectuelle - Direction diocésaine de l`enseignement  NOTA 18/05/2015 n° 5870 - tuttoprevenzioneincendi.it  Inspection Départementale de l`Éducation Nationale  Promate Pyram  ISOLATEUR INDUSTRIEL  Movies, shows, apps and more. This Smart TV does it all.  technical appendix      